HP LH4r HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters

HP LH4r - NetServer - 256 MB RAM Manual

HP LH4r manual content summary:

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

1
HP NetServer LP1000r
with
HP Rack Storage/12FC
Cluster Configuration Guide
21 March 2001
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LP1000r configurations using the HP Rack Storage/12FC
and Microsoft
Cluster Server. These configurations minimize single points of failure (SPOF, SPOFless
1
) and
provide extended availability.
The specific configuration certified and supported by both Hewlett-Packard and
Microsoft
is defined, as are other guidelines to assist you in configuring your clustered NetServers.
This guide
is prescriptive; it describes the configurations supported by HP.
Any deviance to these configurations can result
in an inoperative cluster or an operating cluster with degraded performance, hidden SPOFs, etc., and therefore
will not be supported by HP.
What's Defined in a Racked Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LP1000r
Each node must be the same model SPU, but may have different clock
speeds, main memory sizes, cache sizes, and number of CPUs .
Number of nodes
2
Shared Storage
HP Rack Storage/12FC with 2 FCArray Cards, HP disks, and using an
HP D8602A HBA in each server.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft
approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable, or, configure as a VLAN through an
Ethernet switch.
See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
1
For more information about configuring a SPOFless cluster, refer to the HP white paper,
High Availability
MSCS Cluster Solution
on the HP NetServers, HA Planning website.