HP LH4r HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters
HP LH4r - NetServer - 256 MB RAM Manual
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP LH4r manual content summary:
- HP LH4r | HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters - Page 1
the supported HP NetServer LP1000r configurations using the HP Rack Storage/12FC and Microsoft® Cluster Server. These configurations minimize single points of failure (SPOF, SPOFless1) and provide extended availability. The specific configuration certified and supported by both Hewlett-Packard and - HP LH4r | HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters - Page 2
drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed). Any HP cables that meet SCSI specifications and any SCSI bus speed. Any HP Rack Storage/12FC Required - D5991A Host Bus Adapter Model No. of controllers Driver RAID level Cabinet RAID - HP LH4r | HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters - Page 3
Status SCSI ID Disk SCSI IDs Disk drives: Fibre-channel cables A.002-5 5 (fixed) 0 - 3, 8 - 15 (fixed) Any HP drive supported by storage enclosure Optical (Server to Hub only): 50 meter D6980A 100 meter D6981A Copper (Shared Storage to Hub and Server to Hub ): 3 meter D6978A 5 meter D6979A 10 - HP LH4r | HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters - Page 4
Heavy (blue) lines are fibre channel Optical or Copper cables. See cabling in this guide for specifications. Dashed( green) lines are SCSI offset cables. See cabling in this guide for specifications. HP LP1000r Cluster (SPOF) using HP Rack Storage/12FC and Rack Storage/12 and Fibre Channel Hub 4 - HP LH4r | HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters - Page 5
Power Cabling to Separate Power Circuits (For SPOFless with 2 hubs, connect second hub to PDU that first hub is not attached to) 5 - HP LH4r | HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters - Page 6
or Copper cables. See cabling in this guide for specifications. Dashed( green) lines are SCSI offset cables. See cabling in this guide for specifications. Each copper cable goes to Port 'y'on the RS/12FC array controllers. HP SPOFless LP1000r Cluster using HP Rack Storage/12FC and Rack Storage/12 - HP LH4r | HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters - Page 7
cluster configuration. LEGEND Solid (red) lines are copper fibre channel Dashed (green) lines are SCSI offset cables. See cabling in this guide for specifications. Copper cable goes to Port 'y'on the second RS/12FCarray controller. HP SPOFless LP1000r Cluster using HP Rack Storage/12FC and Rack - HP LH4r | HP Netserver LP 1000r FC Config Guide for Windows NT4.0 Clusters - Page 8
Versions 21 March 2001 Initial release 8
1
HP NetServer LP1000r
with
HP Rack Storage/12FC
Cluster Configuration Guide
21 March 2001
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LP1000r configurations using the HP Rack Storage/12FC
and Microsoft
Cluster Server. These configurations minimize single points of failure (SPOF, SPOFless
1
) and
provide extended availability.
The specific configuration certified and supported by both Hewlett-Packard and
Microsoft
is defined, as are other guidelines to assist you in configuring your clustered NetServers.
This guide
is prescriptive; it describes the configurations supported by HP.
Any deviance to these configurations can result
in an inoperative cluster or an operating cluster with degraded performance, hidden SPOFs, etc., and therefore
will not be supported by HP.
What's Defined in a Racked Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LP1000r
Each node must be the same model SPU, but may have different clock
speeds, main memory sizes, cache sizes, and number of CPUs .
Number of nodes
2
Shared Storage
HP Rack Storage/12FC with 2 FCArray Cards, HP disks, and using an
HP D8602A HBA in each server.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft
approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable, or, configure as a VLAN through an
Ethernet switch.
See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
1
For more information about configuring a SPOFless cluster, refer to the HP white paper,
High Availability
MSCS Cluster Solution
on the HP NetServers, HA Planning website.