HP LH4r HP Netserver LPr RS12/FC Installation Guide

HP LH4r - NetServer - 256 MB RAM Manual

HP LH4r manual content summary:

  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 1
    information specific to your cluster configuration that you will need during installation of your cluster. • HP NetServer Microsoft Cluster Installation Guide - This is the first of two documents used to install the cluster. It covers the installation of all cluster supported HP NetServers and
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 2
    22 February 2000 8 February 2000 Version History Corrected typographical error in Configuration Guide. Under the heading "SPU" the No. of CPUs was changed from "2-4" to "2." Initial release.
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 3
    logical drives Cluster: Install MSCS Reinstall Service Pack Install HotFix (Service Pack 3 only) Testing È Run: Hardware Verification and Labeling Utility Cluster Installation Test (CIT) How to do it! (See the referenced part in the Installation Guide) 1 What's Needed 2 NetServers 3 Shared
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 4
    This page intentionally left blank.
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 5
    defines the supported HP NetServer LPr using the HP Rack Storage/12FC and Microsoft Cluster Server and one or two HP Rack Storage/12s. This configuration minimizes single points of failure (SPOF), provides maximum availability, and has been certified by Hewlett-Packard and Microsoft. This guide is
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 6
    Storage HP NetServer LPr drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP. Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver SPU I/O slot RAID level Cabinet RAID
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 7
    of cabinets: Status SCSI ID Disk SCSI IDs Disk drives: Cables Hub Model Quantity HP 9.1 GB Ultra SCSI Disk Module D6106A HP 9.1 GB Ultra SCSI Disk Module D6107A HP 18.2 GB Ultra SCSI Disk Module D6108A HP 18.2 GB (10k rpm) Ultra SCSI Disk Module D7031A HP 18.2 GB (7200 rpm) Low Profile Ultra SCSI
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 8
    Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LPr, one required HP Rack Storage/12FC and one or two optional HP Rack Storage/12s. Only these cabling configurations and cables are supported. HP Microsoft Cluster using HP Rack Storage
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 9
    HP Microsoft Cluster using HP Rack Storage/12FC and Rack Storage/12 and 6 Port Fibre Channel Hub (Duplex Operation) 5
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 10
    Versions 22 February 2000 8 February 2000 Power Cabling to Separate Power Circuits Corrected typographical error. Under the SPU heading, changed the No. of CPUs from "2-4" to "2." Initial release 6
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 11
    HP NetServer Microsoft Cluster Installation Guide with Shared Storage System Supplement Rack Storage/12FC Rack Storage/12 Rack Storage/8 Storage System/6 HP SureStore E 12H Disk Array or HP A3661B Model 30/FC High Availability Disk Array 18 January 2000 (See Version History below)
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 12
    This page intentionally left blank. HP NetServer Installation Guide 2
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 13
    Microsoft Corp. • Windows and Windows NT are trademarks of Microsoft Corporation. • 3M is a registered Trademark of the 3M Company. Hewlett-Packard Network Server Division 10955 Tantau Avenue Cupertino, CA 95014-0770, USA © Copyright 1999, Hewlett-Packard Company HP NetServer Installation Guide 3
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 14
    FILE SYSTEMS...36 7 MICROSOFT CLUSTER SERVER SOFTWARE SETUP 42 INSTALL MSCS ON SYSTEM A...42 INSTALL MSCS ON SYSTEM B...46 INSTALL SERVICE PACK OR HOT FIX ...46 8 CLUSTER TESTING ...47 HARDWARE VERIFICATION AND LABELING UTILITY 47 CLUSTER INSTALLATION TEST...47 HP NetServer Installation Guide 4
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 15
    local storage. Added installation instructions in part 5 for the LC3. Initial release Intended Audience The guide is for the person who installs, administers, and troubleshoots the Microsoft Cluster Server. Hewlett-Packard assumes this person is qualified to service computer equipment and trained
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 16
    NOTE Hewlett-Packard only supports and recommends installation of clustered HP NetServer systems using Microsoft Cluster Server software by a Microsoft or HP Cluster Certified Installer. HP NetServer Installation Guide 6
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 17
    A Graphical Overview to Setting Up the Cluster CAUTION Departing from the sequence shown here can cause unnecessary work and unpredictable results. HP NetServer Installation Guide 7
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 18
    which includes Windows NT, version 4.0 and Service Pack (SP). Check your Configuration Guide for the applicable Windows NT and SP versions and Microsoft Cluster Server installation software. NOTE Some HP NetServers, as stated in part "5 NetServer Software Setup," require installing Windows NT from
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 19
    • Torx™ T-25 driver supplied in the Rack Installation Toolkit. For rack installed clusters only. • Portable Field Service Grounding Kit (3M® part number 8505, or equivalent). Need More Help? HP Information Assistant provides extensive support information and is available on the HP NetServer Online
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 20
    to the Shared Storage Systems and must be installed in specific PCI slots. See the Configuration Guide for your cluster configuration for the HP NetServer PCI slots to use. See instructions supplied with the component or see part "2 NetServer Hardware Setup" of the Shared Storage Supplement for
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 21
    3 Shared Storage Hardware Setup part "3 Shared Storage Hardware Setup" in the Shared Storage Supplement HP NetServer Installation Guide 11
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 22
    Guide under Plan on the HP NetServers Clustering Solutions web site. Racked clusters - Follow the Road Map supplied with the system and instructions in Connect Shared Storage & Cable the Cluster part "4 Cluster Cabling and Setup" in the Shared Storage Supplement HP NetServer Installation Guide 12
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 23
    Microsoft Service Pack On page ... 13 14 15 16 18 20 22 24 26 28 29 30 32 33 35 LCII Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 24
    addresses must be on different subnets. LC3 Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from the CD and displays the Navigator Main
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 25
    sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from , disable the Embedded IDE Hard Disk Controller. (The embedded IDE controller is not used on HP NetServer systems.) 8. Save and
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 26
    driver version as specified in the Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 27
    in part "1 What's Needed" for additional information. 1. Remove the HP NetServer Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator to reboot the server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 28
    /B NIC drivers must be manually set to the correct LAN speed. Log on and from the start menu select: Settings, Control Panel, NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 29
    drivers you need. If you are using the embedded SCSI channels, load the Symbios driver at this time. 4. Continue the installation and select the following options when prompted: • Choose the unpartitioned space and install Windows NT. • Choose NTFS file system HP NetServer Installation Guide
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 30
    4 These procedures provide instructions for servers using NetRAID, SureStore E 12H, and Model 30/FC shared storage solutions. Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 31
    Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice, once for the intra-cluster NIC and once for the client NIC. • Make sure TCP/IP Protocol is selected. Other protocols may be selected in addition, but TCP/IP is required. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 32
    4 (Fibre Channel) These procedures provide instructions for servers using the HP Rack Storage/12FC. Configure NetServer Hardware and BIOS 1. System A and System B can both be powered on. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. During reboot enter the
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 33
    of the installation guide supplement for additional information. 1. Insert the boot floppy disk for Windows NT4.0 and exit Navigator to reboot the server. 2. When Windows NT Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 34
    and Shared Storage) on page 26. Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. If you have special NetServer local SCSI bus options enter the Symbios utility
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 35
    in part "1 What's Needed" for additional information. 1. Remove the HP NetServer Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator to reboot the server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 36
    storage, you must use two adapters. Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. If you have special NetServer local SCSI bus options enter the Symbios utility
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 37
    to reboot the server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: 3. Load drivers using the NetRAID-3Si Cluster Firmware and Driver floppy disk you created in part 1 "What's Needed" and the NT 4.0 Drivers floppy disk you
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 38
    and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from the CD and displays the Navigator Main menu. NOTE If prompted that the HP NetServer Navigator BIOS is a newer
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 39
    These procedures provide instructions for servers using NetRAID, SureStore E 12H, and Model 30/FC shared storage solutions Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 40
    procedures provide instructions for servers using Fibre Channel shared storage solutions (HP Rack Storage/12FC. Configure NetServer Hardware and BIOS 1. System A and System B can both be powered on. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. During reboot
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 41
    of the installation guide supplement for additional information. 1. Insert the boot floppy disk for Windows NT4.0 and exit Navigator to reboot the server. 2. When Windows NT Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 42
    HBA Driver. LXr 8500 These procedures provide instructions for servers using NetRAID-3Si and the HP Rack Storage/12 shared storage solution. Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 43
    procedures provide instructions for servers using Fibre Channel shared storage solutions (HP Rack Storage/12FC). Configure NetServer Hardware and BIOS 1. System A and System B can both be powered on. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. During reboot
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 44
    unpartitioned space and install Windows NT. • Choose NTFS file system • When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the HP NetServer Installation Guide 34
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 45
    to 100 Mbps. Do not use the Auto setting. Part "6 Shared Storage Software Setup" in the Shared Storage Supplement and start with Install Fibre Channel HBA Driver. Install Service Pack for All HP NetServers Refer to the Configuration Guide for your cluster configuration and install the applicable
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 46
    you identified. An example display follows: NOTE Disk Administrator lists disks in order, beginning with local (non-shared) disks followed by the shared disk arrays. HP NetServer Installation Guide 36
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 47
    dialog appears indicating the maximum size of a single drives. 3. Click OK to include the full disk in the partition (the default). In the following example, Disk 1 has been partitioned and Disk Administrator assigned a temporary drive letter to the disk array. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 48
    Disk Administrator, Partitioned Disk Array NOTE Do not partition a disk into separate drives. Microsoft Cluster Server Software will only manage one partition per disk. 4. Repeat steps 1 through assigned the next sequential letter to the disk array. HP NetServer Installation Guide 38
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 49
    Drive Letter. Disk Administrator displays the Assign Drive Letter dialog. 3. In the dialog, select a drive letter, and click OK. To avoid confusion later, HP recommends that you choose sequential drive letters. The example in this guide uses drive letters X and Y. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 50
    box to select one of the arrays that you just partitioned and assigned a drive letter. Disk Administrator highlights the selected disk. 2. From the Disk Administrator's field type a label (name) for the drive. Choose a descriptive label such as "Shared Drive X.". HP NetServer Installation Guide 40
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 51
    . 6. Repeat steps 1 through 5 to format each drive to be shared in the cluster. The following example depicts both drives formatted with permanent drive letters assigned. Disk Administrator, Formatting and Assigning Volume labels 7. Exit Disk Administrator. HP NetServer Installation Guide 41
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 52
    CD of Microsoft Windows NT Server, Enterprise Edition in the CD-ROM drive of System B. 2. Run the Microsoft Cluster Server setup program. Setup.exe Cluster Server software setup of System A. Click Next. Microsoft Cluster Administrator, Assigning a Cluster Name HP NetServer Installation Guide 42
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 53
    correct MS Domain account, consult the Windows NT documentation supplied with your system. 7. Setup presents a two-column systems. Normally you would share all disks listed. Microsoft Cluster Server Setup, Assigning Shared Disks to the Cluster 8. Setup prompts HP NetServer Installation Guide 43
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 54
    IP Address already filled in. However, your configuration may display the Client LAN first. Microsoft Cluster Server Setup, Assigning a Network Name to the intra-cluster LAN 10. Repeat the previous step for has the highest priority. See the example dialog below. HP NetServer Installation Guide 44
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 55
    specifications and starts the cluster service. 15. Microsoft Cluster Server is now fully installed on System A. Reboot System A. 16. To finish installation of the Microsoft Cluster Server, leave System A running, go to the next procedure and install MSCS on System B. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 56
    not already downloaded clusfixi.exe, see "Software" in part "1 What's Needed." 2. Install the Microsoft hotfix clusfixi.exe on System A and System B. NOTE When downloading the file, refer to the Microsoft readme file for instructions on installing the hotfix. HP NetServer Installation Guide 46
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 57
    to download this program. Run CIT Follow the instructions in the CIT program. If additional information is needed refer to CIT on-line help. CIT help is context sensitive and has been expanded to provide detailed instructions for each step of the program. HP NetServer Installation Guide 47
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 58
    Fibre Channel Supplement to HP NetServer Microsoft Cluster Installation Guide 1 September 1999
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 59
    with hazardous energy levels. Hewlett-Packard only supports and recommends installation of clustered HP NetServer systems using Microsoft Cluster Server software by a Microsoft or HP Cluster Certified Installer. Cluster vs. Standalone This supplement provides instructions specific to installing the
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 60
    without the HP NetServers Microsoft Cluster Installation Guide. NOTICE...2 INTENDED AUDIENCE ...2 CLUSTER VS. STANDALONE ...2 VERSION HISTORY...2 1 WHAT'S NEEDED ...4 SOFTWARE...4 NEED MORE HELP?...4 2 NETSERVER HARDWARE SETUP ...5 3 SHARED STORAGE HARDWARE SETUP 6 INSTALL ADDITIONAL CONTROLLERS
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 61
    controller. 5. Follow on screen instructions to create two FCArray Assistant disks and label them FC Array Assistant Installation Disk #1 and Disk #2. 6. Remove the Navigator CD from the drive. Fibre Channel Cluster Software You must use the cluster certified versions of the fibre channel driver
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 62
    D8602A) in the PCI slots specified by the HP NetServer Configuration Guide for your cluster configuration. 2. Make sure that previously installed cards are in the correct PCI slots. 3. Replace the HP NetServer cover(s) and secure thumbscrews. part "3 Shared Storage Hardware Setup" of this supplement
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 63
    includes instructions for setup of the HP Rack Storage/12FC and HP Rack Storage/12 shared storage devices used in your cluster. Set Configuration Switches for the Rack Storage/12FC (Fibre Channel) Set Configuration Switches for the Rack Storage/12 (SCSI) Fibre Channel Supplement to the HP NetServer
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 64
    Rack Storage/12FC. Install a second SCSI controller (D6025A) in each Rack Storage/12. Follow the instructions supplied with the Controller for installation. to part "4 Cluster Setup and Cabling" of the Installation Guide Fibre Channel Supplement to the HP NetServer Microsoft Cluster Installation
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 65
    all required cable connections can be made and that the layout conforms to usability and safety standards. Shared Storage Power Shared Storage can be on or off. to part "5 NetServer Software Setup of the Installation Guide" Fibre Channel Supplement to the HP NetServer Microsoft Cluster Installation
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 66
    5 NetServer Software Setup This part of the supplement is intentionally left blank. Fibre Channel Supplement to the HP NetServer Microsoft Cluster Installation Guide 9
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 67
    Disk you created earlier in part 1 "What's Needed" into the floppy drive. 6. From the taskbar select Start, then make the following selections: • Settings • Control Panel • SCSI Adapters • Drivers. • Add. • Have Disk. 7. From the floppy disk drive (A:\), select the driver (only one is displayed) and
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 68
    floppy disk and reboot the system. If correct, or after upgrading the firmware, return to part "5 NetServer Software Setup" of the Installation Guide and perform the "Install. Service Pack for All HP NetServers" procedure. Fibre Channel Supplement to the HP NetServer Microsoft Cluster Installation
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 69
    If not already on, turn on power for the HP shared storage cabinet(s). Follow the instructions in the FCArray Assistant Installation and User Guide to complete the following tasks: • Create the Arrays • Disk Arrays • Set RAID levels • Assign LUNs to each logical drive After the Install The following
  • HP LH4r | HP Netserver LPr RS12/FC Installation Guide - Page 70
    After setting RAID levels as stated below return to "Create the Array File Systems" in part "6 Shared Storage Software Setup" of the Installation Guide. Fibre Channel Supplement to the HP NetServer Microsoft Cluster Installation Guide 13
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Microsoft Cluster Installation Documentation
for
HP NetServer LPr
with HP Rack Storage/12FC and HP Rack Storage/12
To assist you in installing your HP NetServer Microsoft Cluster, this file contains the documents
listed below in one pdf file.
Installation Overview
- This page provides an overview of the installation steps provided in
the Installation Guide.
Configuration Guide
- This guide provides configuration information specific to your cluster
configuration that you will need during installation of your cluster.
HP NetServer Microsoft Cluster Installation Guide
- This is the first of two documents used
to install the cluster.
It covers the installation of all cluster supported HP NetServers and the
cluster software, and references the Shared Storage Supplement for installation and setup of the
shared storage.
Shared Storage Supplement
- This supplement is specific to the shared storage device you are
using and must be used with the installation guide.
It provides instructions for installing and
setting up your shared storage devices.
22 February 2000
(See next page)