HP NetServer LXr 8500 with NetRAID-3Si (HP Rack Storage/12) Cluster Configuration Guide 16 October 2000 (see Versions at the end of this document) Introduction This document defines the supported HP NetServer LXr 8500 configurations with HP Rack Storage/12s and Microsoft Cluster Server. These - HP LH4r | HP Netserver LXr 8500 NetRAID-3Si Config. Guide for Windows NT4.0 Clu - Page 2
Operating System Service pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration Storage Microsoft Windows NT Server 4.0, Enterprise Edition SP6a or later HP NetServer LXr 8500 550, 700 MHz 2 - 8 - HP LH4r | HP Netserver LXr 8500 NetRAID-3Si Config. Guide for Windows NT4.0 Clu - Page 3
cable. It may not be used for client communication. Client LAN Any LAN HP D5013A/B (10/100TX PCI) Hptxnt.sys 3.27.00.0001 or later 1 Any that is on both the HP Tested Products List and the Microsoft Hardware Compatibility List. Vendor supported driver NOTE If the NIC used is the same as the Intra - HP LH4r | HP Netserver LXr 8500 NetRAID-3Si Config. Guide for Windows NT4.0 Clu - Page 4
Shared Storage Cabling This part of the guide defines the allowable cabling configuration for clusters using the HP NetServer LXr 8500 and HP Rack Storage/12s. Only this cabling configuration and these cables are supported. LEGEND Color coding depicts that NetRAID channels must not be crossed as - HP LH4r | HP Netserver LXr 8500 NetRAID-3Si Config. Guide for Windows NT4.0 Clu - Page 5
Power Cabling to Separate Power Circuits 5 - HP LH4r | HP Netserver LXr 8500 NetRAID-3Si Config. Guide for Windows NT4.0 Clu - Page 6
Versions 16 October 2000 29 March 2000 1 December 1999 Revised intro and I/O slots. Added boot priority. Changed boot spec. Updated 3Si firmware. Added Ultra3 drives Added support for NetRAID-1Si as a local storage controller. Initial release. 6
1
HP NetServer LXr 8500
with
NetRAID-3Si (HP Rack Storage/12)
Cluster Configuration Guide
16 October 2000
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LXr 8500 configurations with HP Rack Storage/12s and
Microsoft Cluster Server. These configurations minimize single points of failure (SPOF) and provide
extended availability.
The specific configuration certified and supported by both Hewlett-Packard and
Microsoft is defined, as are other guidelines to assist you in configuring your clustered NetServers.
This
guide is prescriptive; it describes the configurations supported by HP.
Any deviance to these
configurations can result in an inoperative cluster or an operating cluster with degraded performance,
hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in a Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LXr 8500
Each node must be the same model SPU, but may have different clocks
speeds, main memory sizes, cache sizes, and number of CPUs.
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-3Si controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
HP D5013A/B with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.16.05 or later