    HP Latex 100/300/500 Printer Series Line Sensor Cleaning
  • HP Latex 330 | Line Sensor Cleaning - Page 2
    The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein
  • HP Latex 330 | Line Sensor Cleaning - Page 3
    performance issue. Refer to the user guide to clean the sensor or call your HP representative if the problem persists. You should also clean the The maintenance cartridge is not detected. ● The printer is unable to read the width of the substrate. Cleaning procedure 1. Turn off the printer and
  • HP Latex 330 | Line Sensor Cleaning - Page 4
    3. Remove the maintenance cartridge by sliding it out. 4. Remove the maintenance cartridge. IMPORTANT: Slide it out horizontally to avoid spills, as it is full of ink. 5. Move the carriage to the right side of the printer to have appropriate access to it from underneath. 2 Line sensor cleaning
  • HP Latex 330 | Line Sensor Cleaning - Page 5
    use a VOC-certified cleaner such as properly diluted Simple Green All-Purpose Cleaner. 7. Move the carriage to the middle of the printer. 8. Reinsert the maintenance cartridge. 9. Slowly push the maintenance cartridge back into the printer. 10. Close the door on the right-hand side. 11. Turn on the