HP ML150 5U Tower G6 Server Redundant Fan option Installation Instructions

HP ML150 - ProLiant - G6 Manual

HP ML150 manual content summary:

  • 1
  • 2

5U Tower G6 Server
Redundant Fan option
Installation Instructions
Legal notices
© Copyright 2009 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The
only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing
herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
Overview
This document contains instructions for installing the optional
Redundant Fan in the HP 5U Tower G6 Server.
For more information on preparing the server for installation, refer to
the documentation referenced on the HP server product CD.
Kit contents
Redundant Fan including holder (2)
Redundant Fan option document
Important safety information
Read the installation instructions completely before beginning the
installation procedure. Refer to the document titled
Important Safety
Information
on the server product CD.
CAUTION:
Electrostatic discharge (ESD) can damage
electronic components. Be sure you are properly
grounded (earthed) before beginning an installation
procedure.
Installation guidelines
This installation is to be performed by qualified personnel who are
knowledgeable of the procedures, precautions, and hazards
associated with equipment containing hazardous energy circuits. For
detailed system board configuration, please refer to hood label
information.
Figure 1
Chassis layout
Item
Description
1
System front fan
2
Rear chassis fan
Installing the Redundant Fan
1.
Back up the server data.
2.
Shut down the operating system (OS) in an orderly manner as
directed in the OS instructions.
3.
If the server is on, press the power button to power down the
server.
4.
Disconnect the power cord from the system chassis.
5.
If necessary, unlock the chassis.
6.
Release the rear thumbscrews and remove the access panel.
7.
Remove the air baffle by pulling up slightly on the four tabs to
release the baffle from the chassis and lift the air baffle away
from the system board and chassis.
Figure 2
Removing the air baffle
8.
Place the server on its side with the open side up.
9.
Remove original fan which locate on fan 1 or 1.5.
Figure 3-1
config 1 original fan locate on fan 1
Figure 3-2
config 2 original fan locate on fan 1.5
10.
Remove the redundant jumper from system board system fan
connector. (Figure 3-3)
NOTE:
Please refer to hood label for jumper location on
system board.
Figure 3-3
Remove the redundant jumper from system board.
11.
Connect the system fan 1 cable to system fan 1 connector of
system board. (Figure 4-1)
12.
Installing system fan 1 to chassis. (Figure 4-2)
Figure 4-1
Connect system board connector
NOTE:
Please refer to hood label for fan 1 connector on
system board.
Part number 530776-001
March 2009 (First Edition)