- HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 1
troubleshooting guidelines and using them each time a memory issue is suspected helps to establish this. HP has developed several methods for troubleshooting memory problems in ProLiant servers. The purpose of this white paper is to assist HP customers in troubleshooting system memory problems - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 2
in the troubleshooting process. When a system memory problem is suspected, check one or all of these common places to find information: • HP System Management Homepage (SMH) • HP Systems Insight Manager (HP SIM) • Server Logs • DIMM Slot LEDs IMPORTANT: When a memory error is detected, the firmware - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 3
to the any of following HP system tools whenever a memory problem is suspected. HP System Management Homepage The HP System Management Homepage supplies a consolidated view of system hardware health, configuration, performance and status information for individual HP servers. Details are provided on - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 4
the hardware in the system and polls installed hardware for its status every few minutes. Refer to Figure 2 below for an example of events displayed on the System page. For more information on HP SIM, refer to the following URL: http://h18013.www1.hp.com/products/servers/management/hpsim/index.html - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 5
Figure 2: HP Systems Insight Manager 5 - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 6
Log (IML) • Event Viewer For servers running Linux operating systems, refer to either of the following: • Integrated Management Log (IML) • varlog/messages file Microsoft Windows Operating Systems: Using the IML The IML Viewer is a software tool created by HP and is available as a downloadable - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 7
available as part of Microsoft Windows operating systems. It can be accessed by navigating to HP System Tools via the Start menu. Figure 4 shows an example of server events that are logged in this tool. Figure 4: Event Viewer (Microsoft Windows Operating Systems) Linux Operating Systems: Using the - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 8
illuminate when certain DIMM slots indicate a failure. The example below is from a ProLiant DL380 G4 system board; however, similar graphics for specific systems can be found in server user guides and other system documentation. Memory Problem Indicators Example DL 380 G4 DIMM Slot LEDs on the - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 9
, refer to the following URL: http://h18013.www1.hp.com/products/servers/management/hpid/index.html Troubleshooting Using HP Insight Diagnostics Online Edition HP Insight Diagnostics Online edition is available in HP ProLiant Support Packs. The Insight Diagnostics Online edition performs various non - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 10
interference from the operating system and address space testing is maximized because a very small Linux kernel is used. Helpful Links: HP Insight Diagnostics User Guide: www.hp.com/servers/diags Troubleshooting Flowcharts The following troubleshooting flowcharts can be used as another tool for - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 11
General Troubleshooting Flowchart for a Bootable System Using HP insight Diagnostics 11 - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 12
General Troubleshooting Flowchart for a Non-Bootable System Use this flowchart to help diagnose a memory problem in any of the following conditions: • The system stops responding and displays a "parity error" message on the screen during boot. • The system beeps and all of the DIMM LEDs illuminate - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 13
replacement, including issues in which memory problems are suspected, are preventable or correctable with a firmware update. HP recommends checking for a firmware update before sending a part back to HP for replacement. Based on the HP ProLiant product return rates, a significant percentage of - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 14
upgrade to multiple servers at one time using the ProLiant Remote Deployment Utility, the ProLiant Remote Deployment Console Utility, and other HP server management technologies, such as HP Systems Insight Manager (HP SIM). The Smart Component updates the firmware and configures the system so that - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 15
.hp.com/products/servers/management/im/index.html Customer Advisory c00683436, Online ROM Flash Tool Available For Updating Firmware On ProLiant Servers And Options, is available at: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c00683436 Updating Firmware Using - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 16
.www1.hp.com/products/servers/technology/whitepapers/adv-technology.html#2 Other Troubleshooting Resources The HP ProLiant Troubleshooting Guide is located at the following URL and may be helpful in diagnosing memory or other system problems: http://h20000.www2.hp.com/bc/docs/support/SupportManual - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 17
PAE Support Is Not Enabled In Microsoft Windows Server 2003: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=PSD_EM04 0802_CW01&jumpid=reg_R1002_USEN First Edition of the HP ProLiant DL380 Generation 5 User Guide Incorrectly States that Advanced ECC Memory Single - HP ML310 | System Memory Troubleshooting Best Practices for HP ProLiant Servers - Page 18
is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
System Memory Troubleshooting Best Practices for HP
ProLiant Servers
Accurately troubleshooting system memory issues in ProLiant server configurations is an important process that
can help prevent unnecessary replacement of hardware components. In addition, accurate problem diagnosis
prevents customers from experiencing unnecessary downtime while waiting for hardware that may not need
to be replaced.
Following standard troubleshooting guidelines and using them each time a memory issue is
suspected helps to establish this.
HP has developed several methods for troubleshooting memory problems in ProLiant servers.
The purpose of this white paper is to assist HP customers in troubleshooting system memory problems by
successfully isolating the specific DIMMs causing the problem. This helps to prevent nonessential replacement
of unaffected DIMMs or, in some cases, entire banks of memory. In addition, effective troubleshooting can
help determine if a firmware or other software download can resolve a problem without replacing hardware.
This white paper covers the following topics:
•
Why should I troubleshoot every system memory problem?
•
How can I tell if a memory problem has occurred?
•
What tools are available from HP to help identify a failing DIMM?
•
Troubleshooting using HP Insight Diagnostics Online Edition
•
Troubleshooting using HP Insight Diagnostics Offline Edition
•
Troubleshooting flowchart for bootable systems
•
Troubleshooting flowchart for non-bootable systems
•
What role does firmware play in solving system memory problems?
•
Why Buy HP Memory?
•
Other troubleshooting resources