HP ProLiant 1850R Compaq ProLiant 1850R Setup and Installation Guide
HP ProLiant 1850R Manual
View all HP ProLiant 1850R manuals
Add to My Manuals
Save this manual to your list of manuals |
HP ProLiant 1850R manual content summary:
- HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 1
Compaq ProLiant 1850R Setup and Installation Guide Second Edition (January 1999) Part Number 333172-002 Compaq Computer Corporation - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 2
, and Windows NT are registered trademarks of Microsoft Corporation. Other product names mentioned herein may be trademarks and/or registered trademarks of their respective companies. Compaq ProLiant 1850R Setup and Installation Guide Second Edition (January 1999) Part Number 333172-002 - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 3
ProLiant 1850R Front View ...1-3 Thumbscrew Identification...1-6 ProLiant 1850R Rear Components 1-7 Locating ProLiant 1850R Server Internal Components 1-8 Industry Support ...1-9 Standard Features ...1-9 Processors and Processor Power Modules 1-9 ProLiant 1850R System Memory 1-10 Expansion Slots - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 4
iv Compaq ProLiant 1850R Features continued Automatic Server Recovery-2 (ASR-2 1-20 Compaq Integrated Remote Console 1-21 Status LEDs...1-22 Security Features ...1-23 Diagnostics ...1-24 Pre-Failure Warranty ...1-24 Insight Manager Alert...1-24 Telephone Numbers...xiv Chapter 2 Server Installation - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 5
Installation Service 2-37 Chapter 3 Installing Hardware Options Accessing Non Hot-Plug Areas 3-2 Accessing Processors, Memory Sockets, and System Board 3-2 Installing a Processor and Processor Power Module 3-4 Installing a Processor Power Module 3-7 Adding Memory to the ProLiant 1850R Server - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 6
ProLiant 1850R Servers 4-12 Internal Cabling...4-13 External Cabling for Primary Storage Only 4-15 External Cabling for Secondary Storage 4-16 ProLiant 1850R Cabling Examples 4-17 ProLiant 1850R Maximum External Storage Cabling 4-19 Chapter 5 Server Configuration and Utilities Compaq System - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 7
...A-3 Taiwan Notice ...A-4 Laser Devices ...A-4 Laser Safety Warnings ...A-4 Compliance with CDRH Regulations A-4 Compliance with International Regulations A-5 Laser Product Label...A-5 Laser Information ...A-5 Battery Replacement Notice ...A-6 Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 8
System Board Switches E-1 System Configuration Switch Settings (S1 Settings E-2 Processor Switch Settings...E-3 NIC Operating Mode ...E-4 SCSI Device Jumper Settings E-4 System Board Battery Jumper Settings E-5 Appendix F Specifications and Connector Interfaces ProLiant 1850R Specifications - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 9
Installing NetWare Lan Drivers G-1 LAN Driver Update Procedure For NetWare 3.2 G-6 Installing IBM OS/2 LAN Drivers G-7 Installing Banyan VINES LAN Driver G-8 Installing SunSoft Solaris 2.5.1, 2.6, and Later Versions (Intel Platforms) +LAN Drivers ...G-10 Index Compaq ProLiant 1850R Setup and - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 10
- HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 11
DIRECTORY NAMES, and DRIVE NAMES Type When you are instructed to type information, type the information without pressing the Enter key. Enter When you are instructed to enter information, type the information and then press the Enter key. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 12
life. CAUTION: Indicates that failure to follow directions could result in damage to equipment or loss of information. IMPORTANT: Presents clarifying information or specific instructions shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce risk of injury from - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 13
other help in the following locations. Compaq Web Site The Compaq Web Site has information on this product as well as the latest drivers and Flash ROM images. You can access the Compaq Web Site by logging on to the Internet at http://www.compaq.com. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 14
About This Guide Telephone Numbers For the name of your nearest Compaq Authorized Reseller: In the United States, call 1-800-345-1518 In Canada, call 1-800-263-5868 For Compaq technical support: In the United States and Canada, call 1-800-386-2172 For Compaq technical support phone numbers outside - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 15
it an unbeatable data center or remote site solution. ProLiant 1850R The Compaq ProLiant 1850R server provides the latest processor and system architecture technology, hot-plug redundant power supply, Error Checking and Correcting Memory, Dual Channel Integrated Wide-Ultra SCSI-3 controller on the - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 16
1-2 Compaq ProLiant 1850R Features Figure 1-2. Compaq ProLiant 1850R server with Wide Ultra2 SCSI - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 17
1-3 ProLiant 1850R Front View ProLiant 1850R with Wide Ultra SCSI-3 The following figure shows the available bay configurations on the front of a server with Wide Ultra SCSI-3. The top ROM drive 3.5-inch 1.44-MB standard diskette drive Continued Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 18
Hot-Plug drive cage accommodating - Two (2) 1.6-inch height Compaq hot-plug hard drives ProLiant 1850R with Wide Ultra2 SCSI The following figure shows the available Wide Ultra2 bay configuration on the front of the server consisting of four 1-inch hot-plug drives. 1 3 2 2 B 1 0 A Figure - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 19
drives 2 A and B two 5.25-inch wide x half height drive bay (removable media area) 2 4 and 5 hot-plug drive cage accommodating from bottom to -two (2) 1-inch height Compaq hot-plug Wide Ultra2 SCSI top hard drives Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 20
1-6 Compaq ProLiant 1850R Features Thumbscrew Identification The following figure shows the location of the thumbscrews used to secure the server to the rack and the thumbscrews used to attach the server cover. 2 1 2 1 2 Figure 1-5. Thumbscrews locations on the front bezel Identifier 1 2 - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 21
components on the rear of the server. 11 1 23 45 6 7 8 9 10 Figure 1-6. ProLiant 1850R rear panel components Reference 1 2 Power Supply Bay (supports optional power supply 2) Standard Hot-Plug Power Supply (power supply 1) External SCSI Ports Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 22
components for the ProLiant 1850R server Identifier 1 2 3 4 Table 1-5 ProLiant 1850R Internal Components Interior Components Hot-Plug Power Supply (225 Watt) Hot-Plug Redundant Power Supply Bay (optional power supply) Memory module sockets (DIMM) (4) Intel Processor (CPU), Socket 1 Continued - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 23
standard on all Compaq ProLiant 1850R models, unless otherwise noted. Processors and Processor Power Modules One processor and integrated 512-KB Level 2 cache Support for up to two Intel Processors Processor Power Module (DC-to-DC converter) Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 24
1-10 Compaq ProLiant 1850R Features ProLiant 1850R System Memory 100-MHz registered SDRAM (Synchronous DRAM) Error Checking and Correcting (ECC) memory uses an error encoding scheme for memory error detection and correction. Specifically, this feature detects and corrects for single-bit memory - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 25
channel on each channel. Optional controller boards available for expanding storage capacity. Optional boards are the SMART-2SL Array Controller, the SMART2DH Array Controller, the SMART-2/P Array Controller, and the WideUltra SCSI-3 Controller. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 26
Ethernet. For more information about the Integrated Network Controller, refer to the Systems Reference Library CD-ROM included in the Reference Information pack. Mass Storage Wide Ultra SCSI-3 Models The Compaq ProLiant 1850R server can house up to 7 mass storage devices for a Wide Ultra SCSI - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 27
5.25-inch wide x half height drive bay (removable media area) SCSI IDs 0, 1, 2 Hot-Plug drive cage with three (3) 1-inch height Compaq hotplug hard drives SCSI IDs 0, 1 Hot-Plug drive cage with two (2) 1.6-inch height Compaq hotplug hard drives Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 28
Features Mass Storage Wide Ultra2 SCSI Models The Compaq ProLiant 1850R server with the Wide Ultra2 SCSI drive cage can house up to 8 mass storage devices. Up to four 1-inch height or two 1.6-inch height Compaq hot-plug hard drives A low profile IDE CD-ROM drive A 3.5-inch, 1.44-MB diskette - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 29
keyboard (color coded orange) Mouse (color coded green) Compaq Netelligent 10/100 TX Embedded UTP Controller with autosensing capability on the PCI local bus IDE Interface for 24X Low Profile CD-ROM drive Floppy Connector Interface Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 30
supply Additional optional hot-plug redundant power supply providing 225-watts of redundant power or 400-watts of load-sharing power. Power Supply LED Warranty Three year on-site limited worldwide warranty Pre-failure warranty on processors, memory, and hard drives if purchased from Compaq - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 31
management features that it provides. As part of the default configuration process you are prompted for your intended installation Operating System. On subsequent re-boots you may change your Operating System selection if you entered a wrong choice. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 32
1-18 Compaq ProLiant 1850R Features An information message indicating that you are running with a default configuration occurs each time you boot the system until you run the System Configuration program. Compaq SmartStart Compaq SmartStart, which is located on the Compaq SmartStart and Support - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 33
prevents faults before they happen, keeps the system running in the unlikely event of a failure, and delivers rapid server recovery to normal operation after a fault. See Chapter 5, "Server Configuration and Utilities," for more information. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 34
20 Compaq ProLiant 1850R Features Compaq System Configuration Utility The Compaq System Configuration Utility performs a wide range of configuration activities including: Configures PCI boards automatically Provides switch and jumper settings Resolves resource conflicts in areas such as memory - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 35
access to system configuration. Uses out-of-band communication with dedicated management modem installed in the server. For information concerning the standard Integrated Remote Console, refer to the Integrated Remote Console Guide included with the shipping box. Compaq ProLiant 1850R Setup and - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 36
1-22 Compaq ProLiant 1850R Features Status LEDs There are three main groups of LEDs: One on each hot-plug power supply, two on the RJ-45 connector and a set of four on the front of the server. Additional LEDs include hard drives and the CD-ROM drive. Front Panel Status LEDs The set of LEDs on the - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 37
on the Systems Reference Library (SRL) CD for more information on these security features. Power-On Password Administrator Password Network Server Mode Diskette Boot Control Serial/Parallel Interface Control QuickLock Power Switch Security Feature Compaq ProLiant 1850R Setup and - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 38
ROMPaq utilities to upgrade flash ROMs Automatic Server Recovery (ASR-2) For information concerning Compaq diagnostic tools, refer to the Systems Reference Library CD included in the Reference Information pack of the shipping box. Pre-Failure Warranty The Compaq ProLiant 1850R server includes Pre - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 39
internal components of the rack-mounted server You can choose the optional installation service from Compaq to install your rack products. See "Optional Installation Service" at the end of this chapter. Figure 2-1. ProLiant 1850R installed in rack Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 40
data, including power requirements, cooling mandates, and physical specifications Ordering information, including required components, part numbers, and appropriate quantities Installing Rack Products This information gives a visual overview of operations required to configure a Compaq rack with - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 41
damage to the equipment, be sure that: The leveling jacks are extended to the floor. The full weight of the rack rests on the leveling jacks. The stabilizers are attached to the rack if it is the rack, and extend only one component at a time. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 42
interruptions with a regulating uninterruptible power supply (UPS). This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure. CAUTION: The Rack-Mountable Compaq ProLiant Server must always be operated with - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 43
Compaq ProLiant 1850R server in a rack, certain standards of temperature and power for servicing and for adequate airflow. Power Requirements WARNING: power load needs to be balanced between available AC supply branch circuits. The overall system Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 44
supplied with that option. Grounding For proper operation and safety, this equipment is required to be properly grounded in accordance with NFPA 70-1993, Article 250. All power Temperature Maximums Equipment Included Rack-Mountable ProLiant Servers Compaq Rack-Mountable options Other manufacturers' - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 45
the option equipment is not exceeded when installed in the rack. Airflow Requirements Compaq ProLiant rackmount servers draw cool air in through the front door and exhaust warm air out the . These gaps need to be covered with blanking panels. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 46
detailed instructions. IMPORTANT: ISA expansion boards are installed after the System Configuration Utility has been run (during the SmartStart portion of the installation sequence). Install other options: Other options include additional memory, hard drives, power supplies, expansion boards, and - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 47
prompted to turn the server off, install any ISA boards (any switch settings required will be provided by the System Configuration utility), and then boot the server from the SmartStart program. Install Compaq Insight Manager to manage the server. For Compaq Management CD initialization procedures - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 48
Installation Overview Unpacking the Rack Server Unpack the server box and locate the materials and documentation necessary to install your rack-mountable server. Locating Materials All of the equipment needed to install the ProLiant 1850R server into the Compaq rack is included with the rack or - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 49
to these supplied items, you may need: Phillips screwdriver Slotted screwdriver Application software diskettes Options to be installed, such as Hot-plug hard drives Memory Additional Pentium II processor and Processor Power Module Array Controllers Compaq ProLiant 1850R Setup and - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 50
for the ProLiant 1850R server and may be obtained from your local Compaq Reseller or Authorized Compaq Service Provider. Hot-plug hard drives Memory Additional Intel next generation processor and Processor Power Module Array Controllers Wide-Ultra SCSI controller boards Tape drives - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 51
mouning bracket. The components of the Slide Rail Assembly include the Outer Bracket Rail which includes the Outer Bracket Rail and the Inner Slide . The Server Rail attaches to the server. 2 1 Figure 2-4. Slide rail assemby components 3 Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 52
rail assemblies (2), rack mounting brackets (2) and 1/4-inch fasteners (4) on a flat surface. 2. Extend the server rail from the outer bracket rail until the server rail release latch clicks . Holding down the latch , slip the server rail out of the inner slide , as shown in the following figure - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 53
. Figure 2-6. Separated outer bracket rail (top) and server rail The outer bracket rail consists of a fixed outer rail that attaches to the rack mounting bracket, and an inner slide on a steel ball-bearing movement. This inner slide does not detach. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 54
2-16 Server Installation Overview To identify the fronts of the rack mounting bracket and the outer bracket rail the inner slide to move forward on ball bearings and can be identified by the plastic guides. 1 2 Figure 2-7. Identify the fronts of the rack mounting bracket and the outer bracket rail - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 55
edge of the rack mounting bracket. The front of both pieces (rack mount bracket and outer bracket rails) should be oriented in the same direction. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 56
for each assembly. 7. Fasten the outer bracket rail to the rack mounting bracket with a 8-32 x 1/4-inch slotted screw. Do not tighten screws until all three screws have been lined up on each assembly. (Do not the inside holes of the rack mounting bracket or the server will sit too high in the rack. - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 57
Attaching outer bracket rail to rack mounting bracket 11. Tighten the three 8-32 x 1/4-inch slotted screws used to fasten the outer bracket rail to the rack mounting bracket. When the three screws total, you use six screws, three for each assembly. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 58
to the floor and support the full weight of the rack. Each rack must be level and stable. Racks that are not coupled together require the installation of stabilizers. This must be done before you perform any work on the rack. See the Rack Planning and Installation Guide for more information on - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 59
positioning for the cage nuts. These are two slots marked "C" on the template. The cage nuts on the front hold the thumbscrews through the server's front bezel, as shown in the following are included in the hardware kit supplied with the rack. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 60
2-22 Server Installation Overview 1. Position the cage nut as shown in the following figure, on the inside of the rail. 2. Hook one of the lips of the - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 61
2-13. Attaching rack mounting bracket assembly to the front of the rack (right side) 2. Carefully align the mounting bracket assembly with the rear rack frame. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 62
2-24 Server Installation Overview 3. Secure the back end of the mounting bracket assembly to the back corner brace of the rack with one M6 x 1.0-12L Phillips to the rack (right view) 4. After attaching both of the mounting bracket assemblies to the rack, prepare the server for mounting in the rack. - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 63
of the rear of the server chassis. The server bracket provides an attachment point for the cable management arm from the server to the rear frame of the rack. Attach the server bracket to the back of the server with two 6-32 x 1/4 Phillips screws. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 64
more manageable, do not install drives or Redundand Hot-Plug Power Supplies in the server until after you load the server into the rack. 1. Pull the slide rail assemblies forward from the rack mounting brackets. 2. Carefully align the server rails with the rack's slide rail assemblies and slide the - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 65
: When servicing the server, fully extend the server until the latches lock. To return the server to the rack, depress the latches and slide the server into the rack. 4. Secure the server front bezel to the front of the rack by screwing the thumbscrews into the cage nuts. Compaq ProLiant 1850R Setup - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 66
of the way when you need to access rear connectors or the hot-plug power supply. 1. For easier handling, first slide the server into the rack, then attach the cable management arm to the cable management arm server bracket using two M6 x 1.0-12L Phillips screws. If you attach the arm before loading - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 67
29 Figure 2-20. Attaching the cable management arm to the cable management arm server bracketG 2. The cable management arm attaches to the rack via the cable washer-face hexhead screws. Figure 2-21. Securing the cable management arm rack bracket Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 68
2-30 Server Installation Overview 3. Align the other end of the cable management arm on the outside You are now ready to connect the power cord and peripheral devices to the connectors located on the rear panel of the server. Icons on the back of the server identify the function of each connector. - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 69
5 Serial Connector B 6 Serial Connector A 7 Key Board Connector (orange) 8 Mouse Connector (green) 9 Hot-Plug Redundant Power Supply Bay (supports optional power supply 2) 10 Standard Hot-Plug Power Supply, with LED 11 External SCSI Access Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 70
the cable management arm and cable support 2. Plug the power cord (s) into the server. Make a small loop in each power supply cable and secure the loop as a strain relief to the location below the power supply. This prevents accidental removal of power cords when the server slides in and out of the - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 71
each power supply. NOTE: Do not place anything on power cords or cables. Arrange them so that no one may accidentally step on or trip over them. Do not pull on a cord or cable. When unplugging from the electrical outlet, grasp the cord by the plug. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 72
. To use the SmartStart and Support Software CD, refer to the Compaq Server Setup and Management pack included in the shipping box. The Compaq System Configuration utility performs a wide range of configuration activities, including: Configures ISA and PCI boards automatically Provides switch - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 73
Setup and Management pack, which is shipped with your server, to configure the system and load the operating system. To manage the system, refer to the Compaq Management CD provided in the Server Setup and Management pack shipped with your server. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 74
firmware diagnostic tools available for your use are: Power-On Self-Test (POST) Diagnostics (DIAGS) ROMPaq utilities to upgrade flash ROMs Automatic Server Recovery (ASR-2) For information concerning Compaq diagnostic tools, refer to the Systems Reference Library CD included in the Reference - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 75
form with pricing is available from PaqFax, the Compaq fax retrieval service. Call 1-800-345-1518, select PaqFax, and request Document No. 4552. Installation can also be ordered from and directly provided by Compaq Authorized Service Providers. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 76
into two major parts: Accessing Removable Media (Non Hot-Plug) Areas - you must shut down the server power to install options, upgrades or replacements in the following areas: Processor sockets Memory sockets System board Expansion boards Rise board and riser board brace Installing - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 77
first shut down the server power. Accessing Processors, Memory Sockets, and System Board WARNING: To reduce the system instructions. 3. Power down the server and remove the power cord (s). IMPORTANT: The system power in the ProLiant 1850R server does not completely shut off with the front panel Power - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 78
3-3 1 1 Figure 3-1. Thumbscrew locations 5. Pull the server out from the rack. IMPORTANT: It is not necessary to completely remove the server from the rack. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 79
inch (2.5 cm), then remove the cover. Figure 3-2. Removing the server cover Installing a Processor and Processor Power Module To install a processor on the System Board, refer to the label inside the server cover, refer to the processor option kit, or follow the procedures below. This procedure can - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 80
times. Failure to follow this process will result in the system failing to boot and halting during the POST test and may result in the system not functioning properly. CAUTION: The heatsink and processor guides are different for the 500-MHz processor. Compaq ProLiant 1850R Setup and Installation - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 81
the socket. Figure 3-4. Sliding the processor into the processor socket (riser board removed for clarity) 2. Push the processor latches outward until the processor latches snap into place. Figure 3-5. Locking the processor into the processor socket (riser board removed for clarity) IMPORTANT: The - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 82
if turned the wrong way. 2. Open latches (optional) , insert the module straight into a socket on the System Board . 2 1 3 Figure 3-6. Installing a processor power module 3. As the module goes into the socket, the socket latches spread open. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 83
use the System Configuration Utility to reconfigure your system. Adding Memory to the ProLiant 1850R Server You can expand server memory by installing Compaq DIMMs (Dual Inline Memory Modules). The system supports up to four Registered SDRAM DIMMs installed in slots on the System Board. Memory can - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 84
3 DIMM Socket 4 Maximum Memory Configuration The ProLiant 1850R server allows ultimate expansion to 1-GB. In the maximum memory configuration, all four DIMM sockets would be populated with 256MB 100-MHz Registered SDRAM (Synchronous DRAM) DIMMs. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 85
the System Board . 3. As the DIMM goes into the socket, the latches close . 4. Press down firmly on the DIMM while pushing the latches inward until the latches snap into place. Identifying Expansion Slots The ProLiant 1850R server's riser board contains four expansion slots: Three PCI slots for - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 86
3-11 Shared PCI/ISA Slot 4 3 2 1 PCI Slots Figure 3-9. ProLiant 1850R riser board slots Expansion boards can be installed in the following slots. 4 3 2 1 Figure 3-10. Locating ProLiant 1850R four (4) expansion slots Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 87
boards in or out of position. 1. If the server is on, shut down the operating system, place it in Standby and disconnect the power cord (s). See Chapter 2, "Server Installation Overview." 2. Slide the server out from the rack. 3. Remove the server cover. 4. Press the top of the expansion slot - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 88
slot. 5 4 Figure 3-13. Inserting an expansion board NOTE: Some full length PCI Boards include a plastic adapter to allow full retention in some shared slots. This adapter must be removed before installing the boards in the ProLiant 1850R server. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 89
must be sent to Compaq as one unit. If they are sent separately, all warranties are voided for those components. Replacing the Riser Board and Riser Board Brace 1. If the server is on, place it in Standby and disconnect the power cord (s). See to Chapter 2, "Server Installation Overview." 2. Remove - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 90
board brace 6. Install the new riser board and riser board brace assembly. When installing this assembly, refer to figure 3-15 for proper alignment. 1 2 Figure 3-16. Installing the riser board and riser board brace 7. Replace all expansion boards. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 91
server cover. 9. Slide the ProLiant 1850 R server into the rack and secure using the thumbscrews. 10. Reconnect all cabling and turn the server on. 11. Reconfigure the server. See to Chapter 5, "Server Configuration and Utilities Compaq SCSI cables for the ProLiant 1850R server are terminated. - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 92
-Ultra SCSI-3 port via an external storage system. Drive bays A and B are 5.25-inch wide x 1.6-inch height drive bays (removable media areas). CAUTION: The ProLiant 1850R server does not support the installation of IDE or EIDE fixed disk drives. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 93
3-18 Installing Hardware Options B A Figure 3-17. Optional mass storage device placement for ProLiant 1850R with Wide Ultra SCSI-3 model 3 2 B 1 0 A Figure 3-18. Optional mass storage device placement for ProLiant 1850R with Wide Ultra2 SCSI model IMPORTANT: A 2 by 1-inch Wide Ultra2 SCSI - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 94
. 3. Remove the server cover. 4. Disconnect the cabling to the 1.44-MB diskette drive. Figure 3-19. Disconnecting the 1.44-MB diskette drive cabling 5. Remove the T-15 torx screw and slide the diskette drive away from front bezel until it stops . Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 95
not damage the eject button on the front of the diskette drive. 4 Front View 3 Figure 3-21. Releasing the 1.44-MB diskette drive from the bottom guide screws - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 96
must use a slender rod (such as the eraser end of a pencil) to depress the center circle of the power switch. To enable the power switch security feature: 1. Power OFF the server and remove power cord (s). IMPORTANT: The system power in the ProLiant 1850R server does not completely shut off with the - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 97
, and the center post of the switch aligns with the hole in the bezel. 1 2 Figure 3-23. Inserting the power switch into the front bezel 8. Replace the 1.44-MB diskette drive and connect cabling. 9. Replace the server cover, slide and secure the server into the rack, and connect external cables. - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 98
CD-ROM adapter board. Figure 3-24. Removing the CD-ROM drive from the chassis Installing the CD-ROM Drive To install the CD-ROM drive into the server, reverse the steps noted in the proceeding procedure. Below is an example of installing the CD-ROM. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 99
Optional mass storage devices can be connected to the Compaq ProLiant 1850R server by using the external Wide-Ultra SCSI-3 port on 1. If the server is on, place it in Standby and disconnect the power cord-(s). See to Chapter 2, "Server Installation Overview". 2. Pull the server forward in the - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 100
server. Figure 3-26. Removing the removable media tray from the server 7. Configure the SCSI ID of the drive as shown with your options instructions. 8. Attach the 3.5-inch drive to the 5.25-inch bracket with the screws provided with your option. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 101
Figure 3-27. Attaching a 3.5-inch drive to a 5.25-inch bracket 9. Install the bracket and drive into the drive bay. Make sure the guide screw lines up with the guide slot in the removable media drive cage. Secure the bracket with one screw through the right side of the drive cage. Figure 3-28 - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 102
server cover. 13. Push the server into the rack and secure it. 14. Reconnect the power cord and power on the server. 15. Reconfigure the server. See to Chapter 5, "Using the System Configuration Utility T-7 Torx screw from the expansion board brace. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 103
. Figure 3-31. Cabling a half height drive to the port 2 with the two device terminated cable 4. Replace the 1.44-MB diskette drive (floppy drive). 5. Replace the server cover. - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 104
and slide the trays out of the server. Figure 3-32. Removing the two removable media trays from the removable media cage 3. Insert the DLT tape drive into the removable media bay area and secure from the bottom of the unit with four T-7 Torx screws. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 105
to the DLT. Figure 3-34. Cabling a DLT tape drive to port 2 with the two device terminated cable 5. Replace the diskette drive (floppy drive). 6. Replace the server cover. 7. Push the server into the rack and secure it. 8. Reconnect the power cord and power on the - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 106
the server. See Chapter 5, "Using the System Configuration Utility," for more information. Accessing the Hot-Plug Areas This section describes accessing the following areas: Hot-Plug SCSI Wide Ultra SCSI-3 Drives Hot-Plug SCSI Wide Ultra2 SCSI Drives Hot-Plug Power Supplies Installing - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 107
hot-plug drive . 3. Close the connector levers . 1 2 Figure 3-36. Installing a Wide Ultra2 SCSI drive NOTE: Push the drive into the slot, then push the drive levers in to lock the drive in place. SCSI ID Numbers for Wide Ultra SCSI-3 Models For Wide Ultra SCSI-3 models, there are two possible SCSI - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 108
drives numbered SCSI ID 0, 1, 2, and 3. The removable media bays can be removed to accommodate two additional hot-plug drives with SCSI ID 4 and 5. 3 2 B 1 0 A Figure 3-38. SCSI ID and removable media numbers for Wide Ultra2 SCSI models Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 109
of the server. 2. Open the lever on the cable management arm and swing the arm out of the way. 1 2 Figure 3-39. Accessing the hot-plug power supplies 3. Remove hot-plug power supply blank. NOTE: The procedure for adding a hot-plug redundant power supply and replacing a power supply are virtually - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 110
in your open area. Push the hot-plug power supply into the slot and swing the arm into the locking position and it locks in place. 1 2 Figure 3-41. Installing a hot-plug power supply 5. Plug the power cord into the new hot-plug power supply. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 111
3-36 Installing Hardware Options Figure 3-42. Plugging in the power cord 6. Secure the power supply cord by fastening it to the clamp on the power supply and attach to the cable management arm. Figure 3-43. Securing the power cord 7. Swing the cable management arm back into place and secure the - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 112
3-37 2 1 Figure 3-44. Securing the cable management arm 8. Close the rear rack door. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 113
power supply. IMPORTANT: Do not place anything on power cords or cables. Arrange them so that no one may accidentally step or trip on them. Do not pull on a cord or cable. When unplugging cords from the electrical outlet, grasp the cord by the plug. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 114
Panel Connectors The illustration below shows the connectors and switches for the ProLiant 1850R server. 11 1 23 45 6 7 8 9 10 Figure 4-1. Location Key Board Connector (orange) 8 Mouse Connector (green) 9 (Optional) Hot-Plug Redundant Power Supply Bay 10 Standard Hot-Plug Power Supply 11 - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 115
running external storage devices from SCSI Port 2 embedded controller, that is the Fast SCSI-2 connector. These connectors are shown below. 1 3 2 3 4 Figure 4-2. SCSI connectors on the system board Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 116
Panel Cables You are now ready to connect the power cord and peripheral devices to the connectors located on the rear panel of the server. Icons on the back of the server identify the function of each connector. Follow the procedure below for instructions on connecting the external cables to the - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 117
Plug in the power supply cables and secure. Figure 4-4. Securing the hot-plug power supply cables 3. Bundle all of the cables, including the power cable (s), and tie them to the cable management arm. Figure 4-5. Cabling the server rear panel cables Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 118
diskette drive For an illustration and table of recommended drive configurations refer to Chapter 1, "Compaq ProLiant 1850R Features." Hot-Plug hard drives for ProLiant 1850R Servers The Compaq ProLiant 1850R server with a wide ultra cage can house up to three hot-plug hard drives, three 1-inch - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 119
Software CD and setup your new configuration. IMPORTANT: The SmartStart and Support Software CD also holds the Compaq System Configuration Utility. Run the System Configuration Utility after you install an option in your ProLiant 1850R Server. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 120
all of the necessary items before beginning the installation process. 1 2 3 4 Figure 4-6. ProLiant 1850R server cabling components Using the following table and figure 4-6 verify that you have the four cables shipped with your server. The cables include the following: One IDE cable for IDE CD - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 121
in all Compaq option kits containing narrow devices. To order an adapter for use with any third-party option, order Option Kit (Part Number 212055-001) direct from Compaq or through your local Compaq Reseller or Authorized Compaq Service Provider. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 122
required for ProLiant 1850R server installation, refer to the illustrations below. Keep in mind these characteristics of SCSI cables: External SCSI cables have a round wire with securable connectors. Internal SCSI cables have a flat ribbon wire with push-on connectors. Compaq SCSI cables - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 123
the tables below are supported by the ProLiant 1850R server. Refer to these tables to determine the parts that are necessary for successful cabling solutions for the ProLiant 1850R. To customize the cabling needs of your Compaq ProLiant 1850R Server to your specific application, follow the procedure - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 124
4-12 Cabling Guidelines Internal SCSI Cabling Guide For Compaq ProLiant 1850R Servers The ProLiant 1850R server includes the following components to be used in cabling the server: One IDE cable for IDE CD-ROM drive One floppy drive cable One two device terminated SCSI cable One point-to- - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 125
4-13 Internal Cabling Compaq ProLiant 1850R Table 4-4 Internal Cabling for the Compaq ProLiant 1850R Wide-Ultra SCSI-3 Fast SCSI-2 Non Hot- and Fast-Wide SCSI- Plug 2 Hot- to connect from the controller to the Wide Ultra2 hot plug back plane. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 126
Cabling Guidelines Internal Cabling for the Compaq ProLiant 1850R Continued Compaq ProLiant 1850R Wide-Ultra SCSI-3 and Fast ROM Drive SMART-2SL Array Controller No additional cables 68 to 50 pin adapter Not Supported. required. Connect the required. Order option kit Wide SCSI pt to PN 212055 - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 127
-Wide cable. Connect external storage device to external Wide-Ultra SCSI-3 Connector (Port 2). Be sure to disconnect internal 2-device cable from port 2 connector in the system board. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 128
4-6 External Cabling for Secondary Storage All ProLiant 1850R Models 4/8 DAT Drive, 4/8 SLR Drive, 12/24 DAT Drive, 20/40GB DLT Drive, and SCSI CD-ROM Drive 15/30 DLT Drive, 35/70 DLT Drive CD Storage System The SCSI Storage Expander Option Kit or Compaq Wide-Ultra Tape Drive Option Kit SCSI - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 129
attached to the inside of the server cover. If you have any problems, contact your local Compaq Authorized Reseller or Service Provider. Connecting an Array Controller to the Hot-Plug Drive Cage Backplane Board Disconnect the point-to-point SCSI cable from the system board and attach it to the Array - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 130
4-18 Cabling Guidelines Cabling a DLT Tape Drive to SCSI Port 2 Figure 4-9. Cabling a DLT tape drive to the port 2 Cabling a Half-Height Tape Drive SCSI Port 2 Figure 4-10. Cabling a half height tape drive to the port 2 - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 131
4-19 ProLiant 1850R Maximum External Storage Cabling Connecting Three Array Controllers For Maximum External Storage Capability from the hot-plug drive cage and run it externally through the empty expansion slot for maximum totally external storage. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 132
: This Compaq system utilities partition should not be confused with the partition(s) created by your operating system. In ProLiant 1850R servers, the system ROM automatically configures the system when adding or removing memory, second processor, or PCI expansion boards. Compaq ProLiant 1850R Setup - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 133
guidelines. The .CFG files for Compaq servers is located on the System Configuration diskettes and Compaq SmartStart and Support Software CD (SmartStart and Support Software CD). For PCI boards, the utility reads the configuration options from the PCI board's configuration space, or as an - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 134
adding, replacing, or removing expansion boards, or when adding a diskette drive or a hard drive. IMPORTANT: The Compaq System Configuration Utility must be run after adding Plug and Play ISA boards to ensure the boards are correctly configured. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 135
the computer. Exit from this Utility - Restarts the computer. System Configuration Menu The following options are available from the System Configuration Utility menu: Configure Hardware Drive Array Configuration Power-On Defaults System Partition Configuration Backup Return to - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 136
step to save the configuration update when you have made changes. Drive Array Configuration This option runs the Compaq Array Configuration Utility. This Utility allows you to view and make changes to a Compaq SMART-2 Array Controller's Configuration. Compaq ProLiant 1850R Setup and Installation - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 137
the hard drive for the utilities. The following menu options are available: Create System Partition Upgrade System Partition Delete System Partition Copy Files Delete Files Creating a New System Partition If you used SmartStart to configure your server, the new System Partition is created - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 138
the Compaq SmartStart and Support Software CD in the CD-ROM drive and turn on the computer. 2. Select Upgrade System Partition. 3. Select to upgrade the utilities. Compaq SmartStart copies the new utilities from the CD to the system partition. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 139
5-8 Server Configuration and Utilities Configuration Backup The Configuration Backup option allows you to create a backup of the system configuration and to restore the system configuration from the backup. The following menu options are available: Backup Restore Configuration Backup and - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 140
System Configuration Utility to change the default automatic settings. Removing Boards System ROM automatically reconfigures the server after a PCI board, DIMM, or second processor is removed. Installing an Operating System Single Processor Operating Support Compaq ProLiant 1850R servers support - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 141
Server Advanced 4.0 with SMP Banyan Vines 8.x SunSoft Solaris 2.5.1, 2.6, and above If you use Compaq SmartStart to install the OS, the drivers are installed automatically. Or when you select the Operating System Installation feature from the System Configuration Utility main menu, the utility - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 142
local reseller or Compaq Customer Service if you need a Compaq SmartStart pack with additional operating system support. Some operating systems have driver support/updates but not an integrated Compaq SmartStart installation. You can still configure your server and manually install your operating - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 143
10/100 TX Controller on a ProLiant 1850R server and you do not plan to use the SmartStart installation process to setup your server, you must install updated support software for your controller to connect properly to the network, refer to Appendix G, "Updating LAN Drivers" for instructions. - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 144
for Microsoft Windows NT from Compaq to support a manual installation of NT drivers. For more information on driver installation, run the README.BAT file in the root directory of the SSD for Windows NT. This will load the WinHelp file NTREADME.HLP. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 145
TX Controller on a ProLiant 1850R server and you do not plan to use the SmartStart installation process to setup your server, you must install updated support software for your controller to connect properly to the network, refer to Appendix G, "Updating LAN Drivers" for instructions. Please check - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 146
on a ProLiant 1850R server and you do not plan to use the SmartStart installation process to setup your server, you must install updated support software for your controller to connect properly to the network, refer to Appendix G, "Updating LAN Drivers" for instructions. Your server must have - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 147
Server Recovery-2 Compaq System Health Compaq ProLiant Storage System Compaq SCSI and Intelligent Disk Array Compaq Fiber Storage Array Support Compaq Remote Insight Board Support Compaq System Utilities Special Considerations Please check the "README" files on the Compaq SmartStart - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 148
on a ProLiant 1850R server and you do not plan to use the SmartStart installation process to setup your server, you must install updated support software for your controller to connect properly to the network, refer to Appendix G, "Updating LAN Drivers" for instructions. Your server must have - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 149
the drivers are installed automatically. Manual installation If you choose not to let Compaq SmartStart configure the server, follow this procedure: 1. Insert the Compaq SmartStart and Support Software CD into the drive. 2. Boot your system. 3. Select Manual Installation. 4. Follow the instructions - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 150
on a ProLiant 1850R server and you do not plan to use the SmartStart installation process to setup your server, you must install updated support software for your controller to connect properly to the network, refer to Appendix G, "Updating LAN Drivers" for instructions. Your server must have - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 151
procedures. These drivers can also be ordered through SoftPaq and can be downloaded from the Compaq Web site. Manual installation 1. Insert the Compaq SmartStart and Support Software CD into the drive. 2. Boot your system. 3. Select Manual Installation. 4. Follow the instructions that display on - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 152
10/100TX UTP Controller that is embedded in this ProLiant 1850R server utilizes the same drivers as the Compaq NetFlex-3 and Netelligent 10/100 family of controllers. For your convenience, some of the popular operating systems and corresponding driver names are listed in the following table. Table - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 153
5-22 Server Configuration and Utilities - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 154
SmartStart and Support Software CD for instructions on installing the appropriate drivers. Multiple Ways of Viewing the Log You can view an event in the Compaq Integrated Management Log in several ways: From within Compaq Insight Manager From within Compaq Survey Utility Compaq ProLiant 1850R - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 155
. System parameters that are monitored describe the status of all key server components. By being able to view the events that may occur to these components, you can take immediate action. You can view and print the event list from within Compaq Insight Manager by following the instructions below - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 156
the output of the utility (typically called SURVEY.TXT) into a text viewer such as Microsoft Notepad. The event list follows the system slot information. Once you have opened the text file, you can print it using the print feature of the viewer. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 157
System Fan Failure (Fan X, Location) System Fan Inserted (Fan X, Location) System Fan Removed (Fan X, Location) System Fans Not Redundant System Overheating (Zone X, Location) Corrected Memory Error threshold passed (Slot X, Memory Module X) Corrected Memory Error threshold passed (System Memory - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 158
X) System Power Supply Inserted (Power Supply X) System Power Supply Removed (Power Supply X) System Power Supplies Not Redundant Real-Time Clock Battery Failing A CPU Power Module (System Board, Socket X) A CPU Power Module (Slot X, Socket X) System AC Power Problem (Power Supply X) System AC Power - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 159
Class B digital device, pursuant to Part 15 of the FCC Rules. These installed and used in accordance with the instructions, may cause harmful interference to radio Compaq Computer Corporation may void the user's authority to operate the equipment. Compaq ProLiant 1850R Setup and Installlation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 160
with the FCC logo United States only This device complies with Part 15 of the FCC Rules. Operation is subject to the Compaq Computer Corporation P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 Or, call (281) 514-3333 To identify this product, refer to the Part, Series, or Model number - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 161
Norms (in brackets are the equivalent international standards): EN55022 (CISPR 22) - Electromagnetic Interference EN50082-1 (IEC801-2, IEC801-3, IEC801-4) - Electromagnetic Immunity EN60950 (IEC950) - Product Safety Japanese Notice Compaq ProLiant 1850R Setup and Installlation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 162
All Compaq systems equipped with a laser device comply with safety standards, including International Electrotechnical Commission (IEC) 825. With specific herein or in the CD-ROM drive installation guide. Allow only Compaq Authorized Service Technicians to repair the laser equipment. Compliance - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 163
International Regulations All Compaq systems equipped with CD- Power Polarization Numerical Aperture Semiconductor GaAIAs 780 nm +/- 35 nm 53.5 degrees +/- 0.5 degrees Less than 0.2 mW /10,869 W·m-2 sr-1 Circular 0.25 0.45 inches +/- 0.04 inches Compaq ProLiant 1850R Setup and Installlation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 164
circuit powered by an internal Lithium Manganese Dioxide or Lithium Vanadium Pentoxide battery. There is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by a Compaq Authorized Service Provider using the Compaq spare - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 165
or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. Use conductive field service tools. Use a portable field service kit with a folding static-dissipating work mat. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 166
B-2 Electrostatic Discharge If you do not have any of the suggested equipment for proper grounding, have an Authorized Compaq Reseller install the part. NOTE: For more information on static electricity, or assistance with product installation, contact your Authorized Compaq Reseller. - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 167
server. For more information on power cord set requirements, contact your Authorized Compaq power cord set must be approved by an acceptable accredited agency responsible for evaluation in the country where the power cord will be used. The power by each country's power system. The appliance - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 168
Cord Set Requirements Country-Specific Requirements Use the following table to identify the appropriate accredited agency in your country. Table C-1 Power Cord Set Requirements - By Country Country Accredited Agency Applicable Note Numbers Australia EANSW 1 Austria OVE 1 Belgium CEBC - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 169
use, battery life is usually about five to ten years. Use Compaq replacement battery part number 160274-001 a 600-milliampere alkaline, 4.5-volt battery. After you have completed the battery installation, run the System Configuration Utility to reconfigure your system. Compaq ProLiant 1850R Setup - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 170
Battery WARNING: The System Board contains a clock/CMOS lithium battery. The lithium battery may explode if mistreated. The battery is soldered in place and may not be removed. Do not abuse or disassemble. Use only replacement batteries supplied by Compaq Computer Corporation (spare part number - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 171
on the System Board. Figure D-2. Attaching the battery to the designated location 9. Reverse steps 1 through 3 to replace the server cover and cable the server, etc. 10. Place the sticker included with your battery kit on the back of your server above the power connector. Compaq ProLiant 1850R Setup - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 172
times. Disconnect power from the server or other product by unplugging the power cord from either the electrical outlet or the server or other product. 12. Turn on the server. 13. Run the Compaq System Configuration utility to reconfigure the system. Refer to Chapter 5, "Server Configuration and - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 173
System Configuration utility. Setting System Board Switches The Compaq ProLiant 1850R System Board has two switch banks (1 and 2) located on the System Board that are used to set the overall configuration of your server. Configuration (SW1) Switch is an 6-position switch (S1-S6) provides processor - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 174
Switch Settings (S1 Settings) The following table defines the function for each switch setting on SW1. Table E-1 System Configuration Switch Settings ON Activates the function Switch Position 1 Function Embedded Video Disable Default Position OFF 2 Configuration Lock OFF 3 Rack - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 175
Function Processor Core Frequency 350 MHz ON Default Position for Processor 400MHz 450MHz ON ON Processor Core Frequency ON OFF OFF Processor Core Frequency OFF ON ON Processor Core Frequency OFF ON OFF 500MHz ON OFF OFF ON Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 176
Jumpers NIC Operating Mode The ProLiant 1850R server comes standard with the Compaq Netelligent 10/100 TX embedded is connected to the same controller, check its SCSI ID in the Compaq System Configuration Utility before beginning the installation procedure for this additional drive. The SCSI ID is - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 177
System Board allows you to choose the internal battery and an external battery. Placing the jumper on pins 6-7 selects the internal battery. Placing the jumper on pins 5-6 selects the external battery. See Appendix D, "Installing a New Battery," for more specific information. Compaq ProLiant 1850R - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 178
, refer to the Systems Reference Library CD. ProLiant 1850R Specifications Table 1-1 ProLiant 1850R Specifications Dimensions Height Depth Width Weight Fully Configured Input Requirements Rated Input Voltage Rated Input Voltage Rated Input Current Power Supply Output Power Rated Steady-State - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 179
and Connector Interfaces ProLiant 1850R Specifications Continued Temperature Range Operating Range 50° to 95 C Connector Interfaces For the pinouts and signals of these connector interfaces, refer to the Systems Reference Library CD: Keyboard Connector (hot-plug) Mouse Connector Serial - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 180
: Following the operating system's driver installation procedures without following the instructions below results in error messages and may effect the operation of your server. Operating Systems Requiring Special LAN Driver Installation Compaq ProLiant 1850R servers support the following operating - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 181
for Small Business from Compaq does not allow intervention to change or modify drivers, you must follow the same procedure for updating your LAN drivers as you will on the drivers for the 53C876 SCSI Controller found on the ProLiant 800/850R and the ProLiant 1850R before starting the installation - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 182
to follow the steps listed below. 1. Scroll to option Select additional drivers (recommended) and press Enter. 2. Press Insert to bring up the screen to select an additional driver. 3. Press F3 to specify a different path. A path dialog box appears. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 183
your local hard drive. Follow the instructions that appear during the copy process. 7. A parameters screen CPQNF3_1 Parameters is displayed after the updated LAN drivers are copied to your local hard drive. 8. Scroll to Slot number and type in the slot number value ID for the embedded LAN controller - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 184
support diskette #3 A:\NETWORK back to the local hard drive"(Drive letter):\PRODUCTS\NW411\IBM\411\LANDRV directory. 4. Install your Operating System. NOTE: This directory containing the CD source may be deleted after completing the installation. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 185
create to your ProLiant system in order to be able to connect to your network with the embedded NIC. Installing Windows NT 4.0 LAN Drivers The LAN drivers on the Microsoft Windows NT 4.0 CD-ROM do not work with the embedded Network Interface Controller on the Compaq Proliant 1850R server. Follow the - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 186
Operating Systems are discussed below: OS/2 Warp Server 4.0 OS/2 Warp Server SMP OS/2 Warp Server Advanced 4.0 OS/2 Warp Connect 3.0 After the installation of the operating system follow the following instructions to install the LAN driver: Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 187
from MPTS. 11. Reboot the system for the driver to take effect. Installing Banyan VINES LAN Driver LAN Driver update procedure for Banyan Vines versions 6.X, 7.X and 8.x. 1. From the SYSTEM MAINTENANCE screen, select Configure/ Diagnose Server. 2. From the SERVER CONFIGURATION screen, select Install - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 188
. 9. Select the Compaq Network Adapter which exists on your system. 10. Change the Slot Number to match the slot that the controller occupies, or for an integrated controller specify any slot number that does not contain a network controller. Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 189
menu. 14. From the operator menu select Shutdown Server Software and reboot your server. The server now boots with the Network controller driver configured as part of the VINES Operating System. This completes the Network controller driver installation. The controller is now in an operable state - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 190
2-26 the server rails to the server 2-25 authorized service providers 2-37 Automatic Server Recovery 1-18, 2-36 Automatic Server Recovery-2 See ASR-2 B Backup configuration 5-8 Banyan Vines device drivers 5-19 LAN drivers G-8 version 8.x 5-10 Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 191
4-5 three array controllers 4-18 cache memory 1-10 cache, integrated 256-KB 1-10 cage nuts for rack model server 2-21 caution running devices off the same SCSI channel (port) 4-3 CD-ROM installation 3-23, 3-24 playing a CD-ROM 2-35 removal 3-23 CD-ROM backplane board location 1-9 CD-ROM drive 4-6 CD - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 192
1-17, 2-36, 5-20 System Configuration Utility 5-20 diagnostics, ROM 1-16 DIMM sockets, illustrated 1-8 DIMMs 1-15 removing 5-9 slot identification 3-9 disassembly 3-1 disk controller 1-11 distributed data guarding drives 1-19 DLT tape drive 4-6 Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 193
LAN drivers G-1 ENET controller 1-12 error checking and correcting (ECC) memory 1-10 error checking and correcting memory 1-15 ethernet connection location 1-7 event list, IML 6-4 event messages log 6-4 expansion (riser) board 3-10 expansion board brace, illustrated 1-9 expansion board slot types - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 194
Manager 6-2. INSPECT Utility 2-35, 5-20 insrting a CD-ROM 2-35 installation 4-11 drive guidelines 4-7 options 3-1 sequence for rack model server 2-8 tools needed for rack model server 2-11 installation sequence 2-8 installations and upgrades 4-11 Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 195
power supply 3-34 a single processor operating system 5-9 an operating system 5-9 batteries D-1 hard drives 4-6 mass storage devices 4-6 mounting bracket assembly for rack server 2-22 operating system 5-9, G-1 processor power module 3-7 rack model server 2-1 SCSI drives 3-16 server 2-8 System Board - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 196
cache 1-10 ECC 1-15 maximum 3-9 module sockets, illustrated 1-8 pre-failure warranty 1-24 system expandability 1-10 system, DIMMs 1-15 memory modules part number listing 3-9 Microsoft OS/2 device drivers 5-17 Microsoft Windows NT device drivers 5-13 Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 197
hot-pluggable redundant power supply 2-12 memory 2-12 processors 2-12 remote insight board 2-12 tape drive 2-12 options overview 2-12 OS/2 device drivers 5-17 OS/2 Warp Connect LAN drivers G-7 OS/2 Warp Server 4.0 LAN drivers G-7 OS/2 Warp Server Advanced 4.0 LAN drivers G-7 OS/2 Warp Server SMP LAN - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 198
socket location, illustrated 3-4 processors XE "processors:socket location, illustrated" power module installation 3-4 ProLiant 1850R front view, illustrated 1-3 ProLiant 1850R specifications F-1 R Rack airflow for 2-7 airflow requirements 2-7 attaching component rail to server 2-25 blanking panels - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 199
RAID levels 1-19 RAM 1-15 rear components, illustrated 1-7 rear panel connectors 4-2 redundant power supply 1-16 redundant power supply, location 1-7 reference information 2-37 Registering the server 2-37 removable media bays bay designation illustrated 1-3, 1-4 removable media bays, illustrated 1-3 - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 200
2-27 serial connector port B location 1-7 serial connectors A and B 2-31 server Health Logs 1-17 internal components locations 1-8 loading into rack 2-26 management and configuration 1-17 rack mounting bracket 2-14 rack slide rail assembly 2-14 Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 201
slots 1-10 fault tolerance 1-19 front panel LEDs 1-22 hot-plug redundant power supply 1-16 Insight Manager Alert 1-24 integrated 256-KB secondary cache 1-10 power module 1-9 pre-failure warranty 1-24 processor board 1-9 security 1-23 SmartStart 1-18 system memory 1-10 Server Health Logs 1-18 server - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 202
terminated SCSI cable 4-8 U unpacking 2-10 utilities 5-20 Compaq System Configuration Utility 1-20 configuration utilities 2-34 Diagnostics 5-20 EISA Configuration Utility 2-9 INSPECT Utility 2-35 Inspect Utility, running after configuration 5-20 Compaq ProLiant 1850R Setup and Installation Guide - HP ProLiant 1850R | Compaq ProLiant 1850R Setup and Installation Guide - Page 203
Survey Utility 6-3 System Configuration 5-1 System Configuration Utility 2-34 TEST Utility 2-35 V video connector (black) 2-31 connector location 1-7 VINES device drivers 5-19 W warnings rack installation 2-3 server installation 2-4 warranty 1-16 pre-failure 1-24 Website location Compaq G-2 SunSoft
Compaq ProLiant 1850R
Setup and Installation Guide
Second Edition (January 1999)
Part Number 333172-002
Compaq Computer Corporation