HP ProLiant BL25p Microsoft Windows Event ID and SNMP Traps Reference Guide fo
HP ProLiant BL25p - G2 Server Manual
View all HP ProLiant BL25p manuals
Add to My Manuals
Save this manual to your list of manuals |
HP ProLiant BL25p manual content summary:
- HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 1
Microsoft Windows Event ID and SNMP Traps Reference Guide For use with SmartStart version 8.25 Part number: 347870-009 Ninth edition: June 2009 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 3
Contents Introduction ...4 Windows NT® event log format ...4 Agent descriptions ...4 Where to go for additional help ...5 Telephone numbers ...5 Foundation agents...6 Event Identifiers 256-774 ...6 Event Identifiers 1105-1808 ...9 Event Identifiers 2048-2359 ...17 Event Identifiers 3072-3876 ...21 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 4
the events in this document includes Event Severity, Event Message, Event Message Source, Event Symptom, and Supporting SNMP Trap Data. Windows NT® event log format The following pages contain HP Insight Management events that are entered into the Microsoft® Windows NT® Event Log when they occur - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 5
: • In the United States, see the HP US service locator webpage, http://www.hp.com/service_locator. • In other locations, see the HP website, http://www.hp.com. For HP technical support: • In North America: ○ Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 6
insertion string is: %1. The data contains the error code. Event identifier: cpqhsmsg.dll - 257 (Hex)0x84350101 (Service Event) Log Severity: Warning (2) Log Message: The Foundation Agents service could not allocate memory. The data contains the error code. Event identifier: cpqhsmsg.dll - 258 (Hex - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 7
invalid state for agent "%1". The data contains the state. Event identifier: cpqhsmsg.dll - 269 (Hex)0x8435010d (Service Event) Log Severity: Warning (2) Log Message: The Foundation Agents service could not stop agent "%1". The data contains the error code. Event identifier: cpqhsmsg.dll - 270 (Hex - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 8
error while attempting to retrieve data from key = %1 in the registry. The data contains the error code. Event identifier: cpqhsmsg.dll - 771 (Hex)0x84350303 (Service Event) Log Severity: Warning (2) Log Message: The Host Remote Alerter was unable to log an event in the event log of the system named - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 9
error code. Event identifier: cpqhsmsg.dll - 774 (Hex)0xc4350306 (Service Event) Log Severity: Error (3) Log Message: The Host Remote Alerter .MIB Symptom: Generic trap. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHoGenericData Supporting SNMP Trap Description: "[cpqHoGenericData]" - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 10
within the variable list are those of the alarm entry that generated this trap. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqMeAlarmVariable • cpqMeAlarmSampleType • cpqMeAlarmValue • cpqMeAlarmFallingThreshold • cpqMeAlarmOwner • cpqMeAlarmSeverity • cpqMeAlarmExtendedDescription - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 11
SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHoSwRunningTrapDesc Supporting SNMP Trap Description: "[cpqHoSwRunningTrapDesc]" NT Event ID: 1167 (Hex)0x8435048f (cpqhsmsg.dll) Log Severity: Warning (2) Log Message: The cluster resource %4 has become degraded. SNMP Trap: cpqClusterResourceDegraded - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 12
name, and then check the resource for the cause of the degraded condition. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqClusterResourceName Supporting SNMP Trap Description: "Cluster resource [cpqClusterResourceName] has become degraded." NT Event ID: 1168 (Hex)0xc4350490 (cpqhsmsg.dll - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 13
node name, and then check the node for the cause of the degraded condition. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqClusterNodeName Supporting SNMP Trap Description: "Cluster service on [cpqClusterNodeName] has become degraded." NT Event ID: 1172 (Hex)0xc4350494 (cpqhsmsg.dll) Log - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 14
CPQWINOS.MIB Symptom: The Processor Time performance property is set to critical. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqOsCpuIndex • cpqOsCpuInstance • cpqOsCpuTimePercent Supporting SNMP Trap Description: "The Processor performance Instance, [cpqOsCpuInstance] is critical with - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 15
.MIB Symptom: The Cache CopyReadHits performance property is set to critical. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqOsCacheIndex • cpqOsCacheInstance • cpqOsCacheCopyReadHitsPercent Supporting SNMP Trap Description: "The Cache performance property is critical with CopyReadHits - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 16
LogicalDisk BusyTime performance property is set to degraded. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqOsLogicalDiskIndex • cpqOsLogicalDiskInstance • cpqOsLogicalDiskBusyTimePercent Supporting SNMP Trap Description: "The LogicalDisk performance instance, [cpqOsLogicalDiskInstance - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 17
Supporting SNMP Trap Description: "[cpqHoCriticalSoftwareUpdateData]" Event identifier: cpqhsmsg.dll - 1792 (Hex)0x84350700 (Service Event trap. This can be caused by a failure in the Remote Access Service or by a missing or invalid configuration. Use the Management Agents control - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 18
caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 2051 (Hex)0x84350803 (Service Event) Log Severity: Warning (2) Log Message: Unable to read from the registry. This error can be caused by a corrupt registry or a low - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 19
This error can be caused by a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 2101 (Hex)0x84350835 (Service Event) Log Severity: Warning (2) Log Message: Unable to acquire the CPU performance data. This error can be caused by a low memory condition - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 20
Log Severity: Warning (2) Log Message: The Threshold Agent SNMP request failed. The data contains the error code. Action: 1) Be sure that the SNMP service is configured to allow SNMP requests from "localhost". 2) Be sure that there is an adequate amount of free memory. Event identifier: cpqhsmsg.dll - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 21
the variable because the value is invalid or out of range. The data contains the error code. Event identifier: cpqhsmsg.dll - 2359 (Hex)0x84350937 (Service Event) Log Severity: Warning (2) Log Message: The Threshold Agent is not loaded. Sets are not available. The data contains the error code. Event - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 22
this error. Event identifier: cpqhsmsg.dll - 3855 (Hex)0x84350f0f (Service Event) Log Severity: Warning (2) Log Message: Could not open a cluster enumeration object. The Cluster service may not be running. Try to restart the Cluster service. Event identifier: cpqhsmsg.dll - 3856 (Hex)0x84350f10 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 23
Event) Log Severity: Warning (2) Log Message: Could not get the cluster's status. The Cluster service may not be running. Try to restart the Cluster service. Event identifier: cpqhsmsg.dll - 3858 (Hex)0x84350f12 (Service Event) Log Severity: Warning (2) Log Message: Could not open the enumerated - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 24
: The Agent could not open the Cluster service registry key. Event identifier: cpqhsmsg.dll - 3872 (Hex)0x84350f20 (Service Event) Log Severity: Warning (2) Log Message: The specified storage class is not supported by the Agent. The Agent only supports the disk resource class. Event identifier - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 25
Log Message: Could not enumerate the cluster's networks. The Cluster service may not be running. Try to restart the Cluster service. Event Identifiers 4352-4626 Event identifier: cpqhsmsg.dll - 4352 (Hex)0x84351100 (Service Event) Log Severity: Warning (2) Log Message: The External Status MIB Agent - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 26
got an unexpected error code while waiting for an event. The data contains the error code. Event identifier: cpqhsmsg.dll - 4363 (Hex)0x8435110b (Service Event) Log Severity: Warning (2) Log Message: The External Status MIB Agent did not respond to a request. The data contains the error code. Event - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 27
Warning (2) Log Message: The Agent could not access WMI. The WMI support may have not been started or installed. Restart or Install WMI service and restart the agents. Event identifier: cpqhsmsg.dll - 4624 (Hex)0x84351210 (Service Event) Log Severity: Warning (2) Log Message: The Agent requires WMI - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 28
or may still be in the starting state. Event identifier: cpqhsmsg.dll - 4626 (Hex)0x84351212 (Service Event) Log Severity: Warning (2) Log Message: The Agent failed to process the MOF file to get the data from WMI. Problem with WMI service or MOF file or wrong file paths used. Foundation agents 28 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 29
The insertion string is: %1. The data contains the error code. Event identifier: cpqstmsg.dll - 257 (Hex)0x84350101 (Service Event) Log Severity: Warning (2) Log Message: The Storage Agents service could not allocate memory. The data contains the error code. Event identifier: cpqstmsg.dll - 258 (Hex - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 30
load the module "%1". The data contains the error code. Event identifier: cpqstmsg.dll - 265 (Hex)0x84350109 (Service Event) Log Severity: Warning (2) Log Message: The Storage Agents service could get the control function for module "%1". The data contains the error code. Event identifier: cpqstmsg - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 31
the server may correct this error. Event identifier: cpqstmsg.dll - 526 (Hex)0x8435020e (Service Event) Log Severity: Warning (2) Log Message: Unsupported storage system. The ProLiant storage system %1 is not supported by this version of the Storage Agents. Upgrade the agents to the latest version - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 32
Agent detected an error while attempting to log an alert remotely. The data contains the error code. Event identifier: cpqstmsg.dll - 771 (Hex)0x84350303 (Service Event) Log Severity: Warning (2) Log Message: The Remote Alerter Agent was unable to log an event in the event log of the system named - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 33
of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current logical drive status. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaLogDrvStatus Supporting SNMP Trap Description: "Status is now [cpqDaLogDrvStatus]." NT Event ID: 1063 (Hex)0xc4350427 (cpqstmsg - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 34
. User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaPhyDrvStatus • cpqDaPhyDrvCntlrIndex • cpqDaPhyDrvBusNumber • cpqDaPhyDrvBay • cpqDaPhyDrvModel • cpqDaPhyDrvFWRev • cpqDaPhyDrvSerialNum - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 35
has been lost. User Action: Verify that no data has been lost. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrSlot • cpqDaCntlrModel • cpqDaAccelSerialNumber • cpqDaAccelTotalMemory Supporting SNMP Trap Description: "Accelerator lost battery power. Data Loss possible." NT Event - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 36
in the controller status of a SCSI Controller. The variable cpqScsiCntlrStatus indicates the current controller status. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqScsiCntlrStatus Supporting SNMP Trap Description: "Status is now [cpqScsiCntlrStatus]." NT Event ID: 1069 (Hex)0xc435042d - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 37
current fan status. User Action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxFanStatus Supporting SNMP Trap Description: "Storage System fan status changed to [cpqSsBoxFanStatus]." NT Event ID: 1076 (Hex)0xc4350434 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 38
by the administrator. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxTempStatus Supporting SNMP Trap Description: "Storage System temperature ok." Event identifier: cpqstmsg.dll - 1098 (Hex)0x4435044a (Service Event) Log Severity: Information (1) Log Message - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 39
air flow changes caused by the missing side panel. User Action: Replace the storage system side panel. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxSidePanelStatus Supporting SNMP Trap Description: "Side panel is removed from unit." NT Event ID: 1102 (Hex)0x4435044e (cpqstmsg.dll - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 40
to have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqTapePhyDrvCondition Supporting SNMP Trap Description: "Status is now [cpqTapePhyDrvCondition]." NT Event ID: 1120 (Hex)0x84350460 (cpqstmsg.dll) Log - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 41
for replacement. For detailed information on a component replacement, see the appropriate Maintenance and Service Guide. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqIdeIdentIndex Supporting SNMP Trap Description: "IDE drive [cpqIdeIdentIndex] has become degraded." NT Event ID: 1122 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 42
status. User Action: If the physical drive status is threshExceeded(4), predictiveFailure(5) or failed(6), replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqFcaPhyDrvBusNumber • cpqFcaPhyDrvBay • cpqFcaPhyDrvStatus Storage agents 42 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 43
Action: If the spare drive status is failed, replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqFcaSpareBusNumber • cpqFcaSpareBay • cpqFcaSpareStatus Supporting SNMP Trap Description: "Spare Status is now [cpqFcaSpareStatus] on bus - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 44
SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqFcaAccelBoxIoSlot • cpqFcaCntlrModel • cpqFcaAccelSerialNumber • cpqFcaAccelTotalMemory Supporting SNMP Trap Description: "Accelerator lost battery power. Data Loss possible." NT Event ID: 1150 (Hex)0xc435047e - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 45
box has been lost. Check the storage box and all fibre channel connections for problems. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqFcaCntlrBoxIoSlot • cpqFcaCntlrStatus • cpqFcaCntlrModel • cpqFcaCntlrSerialNumber • cpqFcaAccelTotalMemory - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 46
Action: If the power supply status is failed, restore power or replace the failed power supply. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqSsPowerSupplyBay • cpqSsPowerSupplyStatus • cpqSsPowerSupplySerialNumber • cpqSsPowerSupplyBoardRevision - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 47
as soon as possible. Be sure that the storage system environment is being cooled properly and that no components are overheated. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqSsTempSensorLocation • cpqSsTempSensorStatus • cpqSsTempSensorCurrentValue - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 48
Degraded. The Insight Agent has detected that an autoloader unit is in a degraded condition. • Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqTapeLibrarySerialNumber Supporting SNMP Trap Description: "Tape library [cpqTapeLibrarySerialNumber] is in a degraded condition." NT Event ID - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 49
Door Closed. The Insight Agent has detected that the door on an autoloader has closed. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqTapeLibrarySerialNumber Supporting SNMP Trap Description: "Tape library [cpqTapeLibrarySerialNumber] door closed." NT Event ID: 1161 (Hex)0xc4350489 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 50
. User Action: Check the partner controller for problems. If this was the result of a user initiated switchover, no action is required. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrSlot • cpqDaCntlrPartnerSlot Supporting SNMP Trap Description: "Controller in slot [cpqDaCntlrSlot - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 51
tapes has been lost. Check the tape library and all Fibre connections for problems. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeCntlrWWN • cpqFcTapeCntlrStatus Supporting SNMP Trap Description: "Status is now [cpqFcTapeCntlrStatus] for tape controller [cpqFcTapeCntlrWWN]." NT - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 52
, check the tape and all fibre channel connections. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeCntlrWWN • cpqFcTapeDriveScsiBus • cpqFcTapeDriveScsiTarget • cpqFcTapeDriveScsiLun • cpqFcTapeDriveStatus Supporting SNMP Trap Description: "Status is now [cpqFcTapeDriveStatus] for - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 53
indicates the new active controller index. User Action: Check the partner controller for problems. If this was the result of a user initiated switchover, no action is required. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime Storage agents 53 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 54
library. User Action: If the tape library is failed, check the tape library front panel. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaTapeLibraryCntlrIndex • cpqDaTapeLibraryScsiBus • cpqDaTapeLibraryScsiTarget • cpqDaTapeLibraryScsiLun • cpqDaTapeLibraryModel • cpqDaTapeLibraryFWRev - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 55
inserted and run. This causes the tape drive heads to be cleaned. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaTapeDrvCntlrIndex • cpqDaTapeDrvBusIndex • cpqDaTapeDrvScsiIdIndex • cpqDaTapeDrvLunIndex Supporting SNMP Trap Description: "Cleaning is needed for the tape drive." Storage - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 56
used and therefore needs to be replaced with a new cleaning tape. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaTapeDrvCntlrIndex • cpqDaTapeDrvBusIndex • cpqDaTapeDrvScsiIdIndex • cpqDaTapeDrvLunIndex Supporting SNMP Trap Description: "Cleaning tape needs replacing." NT Event ID - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 57
If the physical drive status is smartError(3) or failed(4), replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqIdeAtaDiskControllerIndex • cpqIdeAtaDiskIndex • cpqIdeAtaDiskModel • cpqIdeAtaDiskFwRev • cpqIdeAtaDiskSerialNumber • cpqIdeAtaDiskStatus • cpqIdeAtaDiskChannel - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 58
status. User Action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqSsBackplaneIndex • cpqSsBackplaneVendor • cpqSsBackplaneModel • cpqSsBackplaneSerialNumber • cpqSsBackplaneFanStatus - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 59
of a tape library. The current tape library status is indicated in the cpqTapeLibraryState variable. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqTapeLibraryCntlrIndex • cpqTapeLibraryBusIndex • cpqTapeLibraryScsiIdIndex • cpqTapeLibraryLunIndex • cpqTapeLibraryName Storage agents 59 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 60
indicates the current tape status. User Action: If the tape is failed or is offline, check the tape and all connections. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeDriveCntlrIndex • cpqFcTapeDriveScsiBus • cpqFcTapeDriveScsiTarget • cpqFcTapeDriveScsiLun Storage agents 60 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 61
tape inserted and run. This causes the tape drive heads to be cleaned. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeDriveCntlrIndex • cpqFcTapeDriveScsiBus • cpqFcTapeDriveScsiTarget • cpqFcTapeDriveScsiLun • cpqFcTapeDriveModel • cpqFcTapeDriveFWRev • cpqFcTapeDriveSerialNumber - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 62
(8) or secondaryRunningUser(9), examine the primary server for failed components. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqSsChassisRsoStatus • cpqSsChassisIndex Supporting SNMP Trap Description: "Storage system recovery server option status - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 63
door status. User Action: If the tape library door is open, close the tape library door. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeLibraryCntlrIndex • cpqFcTapeLibraryScsiBus • cpqFcTapeLibraryScsiTarget • cpqFcTapeLibraryScsiLun • cpqFcTapeLibraryModel • cpqFcTapeLibraryFWRev - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 64
is cableProblem(4), check the cable connections between the controller and the storage system. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaCntlrIndex • cpqDaCntlrBoardStatus • cpqDaCntlrModel • cpqDaCntlrSerialNumber • cpqDaCntlrFWRev • cpqDaAccelTotalMemory - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 65
. User Action: If the physical drive status is failed(3) or predictive Failure(4), replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaPhyDrvCntlrIndex • cpqDaPhyDrvIndex • cpqDaPhyDrvBusNumber • cpqDaPhyDrvBay • cpqDaPhyDrvModel • cpqDaPhyDrvFWRev - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 66
Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaPhyDrvCntlrIndex • cpqDaPhyDrvIndex • cpqDaPhyDrvBusNumber • cpqDaPhyDrvBay • cpqDaPhyDrvModel • cpqDaPhyDrvFWRev • cpqDaPhyDrvSerialNum Supporting SNMP Trap Description: "Factory threshold passed for a physical drive." NT Event ID - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 67
lost. User Action: Verify that no data has been lost. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaCntlrModel • cpqDaAccelCntlrIndex • cpqDaAccelSerialNumber • cpqDaAccelTotalMemory Supporting SNMP Trap Description: "Accelerator lost battery power. Data Loss - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 68
the tape library. User Action: If the tape library door is open, close the tape library door. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaTapeLibraryCntlrIndex • cpqDaTapeLibraryScsiBus • cpqDaTapeLibraryScsiTarget • cpqDaTapeLibraryScsiLun Storage agents 68 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 69
drive. User Action: If the tape is failed, check the tape and all SCSI connections. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaTapeDrvCntlrIndex • cpqDaTapeDrvBusIndex • cpqDaTapeDrvScsiIdIndex • cpqDaTapeDrvLunIndex • cpqDaTapeDrvName • cpqDaTapeDrvFwRev - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 70
that has been fully used and therefore needs to be replaced with a new cleaning tape. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaTapeDrvCntlrIndex • cpqDaTapeDrvBusIndex • cpqDaTapeDrvScsiIdIndex • cpqDaTapeDrvLunIndex • cpqDaTapeDrvName • cpqDaTapeDrvFwRev - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 71
SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxCntlrHwLocation • cpqSsBoxCntlrIndex • cpqSsBoxBusIndex • cpqSsBoxVendor • cpqSsBoxModel • cpqSsBoxSerialNumber • cpqSsBoxTempStatus Supporting SNMP Trap Description: "Storage System temperature status changed to [cpqSsBoxTempStatus]." NT Event ID - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 72
: If the power supply status is degraded, restore power or replace the failed power supply. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxCntlrHwLocation • cpqSsBoxCntlrIndex • cpqSsBoxBusIndex • cpqSsBoxVendor • cpqSsBoxModel • cpqSsBoxSerialNumber • cpqSsBoxFltTolPwrSupplyStatus - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 73
Action: If the physical drive status is failed (3) or predictiveFailure (4), replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaPhyDrvCntlrIndex • cpqDaPhyDrvIndex • cpqDaPhyDrvLocationString • cpqDaPhyDrvType • cpqDaPhyDrvModel • cpqDaPhyDrvFWRev - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 74
User Action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxCntlrHwLocation • cpqSsBoxCntlrIndex • cpqSsBoxBusIndex • cpqSsBoxVendor • cpqSsBoxModel • cpqSsBoxSerialNumber • cpqSsBoxFanStatus • cpqSsBoxLocationString - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 75
: If the power supply status is degraded, restore power or replace the failed power supply. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxCntlrHwLocation • cpqSsBoxCntlrIndex • cpqSsBoxBusIndex • cpqSsBoxVendor • cpqSsBoxModel • cpqSsBoxSerialNumber • cpqSsBoxFltTolPwrSupplyStatus - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 76
• cpqSasHbaHwLocation • cpqSasLogDrvHbaIndex • cpqSasLogDrvIndex • cpqSasLogDrvStatus • cpqSasLogDrvOsName Supporting SNMP Trap Description: "Status is now [cpqSasLogDrvStatus]." Event identifier: cpqstmsg.dll - 1280 (Hex)0x84350500 (Service Event) Log Severity: Warning (2) Log Message: Unable to - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 77
1294 (Hex)0x8435050e (Service Event) Log Severity: Warning (2) Log Message: Unsupported storage system. The ProLiant storage system %1 is unsupported may not support this SCSI controller. You may need to update your system ROM. Event identifier: cpqstmsg.dll - 1344 (Hex)0x84350540 (Service Event) - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 78
Agents package to correct this error. Event identifier: cpqstmsg.dll - 1796 (Hex)0x84350704 (Service Event) may correct this problem. Event identifier: cpqstmsg.dll - 1803 (Hex)0xc435070b (Service Event) Log Severity Remote Access Service or by a missing or invalid configuration. Use the HP Insight - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 79
(2) Log Message: The IDE Agent could not create an event. The data contains the error code. Event identifier: cpqstmsg.dll - 3591 (Hex)0x84350e07 (Service Event) Log Severity: Warning (2) Log Message: The IDE Agent could not open an event. The data contains the error code. Event identifier: cpqstmsg - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 80
got an unexpected error code while waiting for an event. The data contains the error code. Event identifier: cpqstmsg.dll - 3598 (Hex)0x84350e0e (Service Event) Log Severity: Warning (2) Log Message: The IDE Agent got an unexpected error code while waiting for multiple events. The data contains the - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 81
by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 4610 (Hex)0x84351202 (Service Event) Log Severity: Warning (2) Log Message: Could not write the registry subkey: "%1". This error can be caused by a corrupt registry or - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 82
The insertion string is: %1. The data contains the error code. Event identifier: cpqsvmsg.dll - 257 (Hex)0x84350101 (Service Event) Log Severity: Warning (2) Log Message: The Server Agents service could not allocate memory. The data contains the error code. Event identifier: cpqsvmsg.dll - 258 (Hex - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 83
not unload the module "%1". The data contains the error code. Event identifier: cpqsvmsg.dll - 272 (Hex)0x84350110 (Service Event) Log Severity: Warning (2) Log Message: The Server Agents service could not create the registry key "%1". The data contains the error code. Event identifier: cpqsvmsg.dll - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 84
while attempting to retrieve data from key = %1 in the registry. The data contains the error code. Event identifier: cpqsvmsg.dll - 771 (Hex)0x84350303 (Service Event) Log Severity: Warning (2) Log Message: The Remote Alerter Agent was unable to log an event in the event log of the system named - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 85
. The Online Spare Memory has been activated. User Action: Schedule server down time to replace the faulty memory. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "The Advanced Memory Protection subsystem has engaged the online spare memory." NT Event ID: 1026 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 86
subsystem has detected a memory fault. The XOR engine has been activated. User Action: Replace the faulty memory. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "The Advanced Memory Protection subsystem has engaged the XOR memory." NT Event ID: 1029 (Hex - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 87
.MIB Symptom: The Fault Tolerant Fans have returned to a redundant state for the specified chassis. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeFltTolFanChassis Supporting SNMP Trap Description: "The Fans are now redundant on Chassis [cpqHeFltTolFanChassis]." NT Event ID: 1035 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 88
not processor-based. User Action: None. SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeResMem2BoardSlotNum • cpqHeResMem2BoardCpuNum • cpqHeResMem2BoardRiserNum Supporting SNMP Trap Description: "Memory Board or Cartridge Inserted into Slot [cpqHeResMem2BoardSlotNum], Cpu[cpqHeResMem2BoardCpuNum - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 89
fault. The LockStep recovery engine has been activated. For instruction on replacing the faulty memory, see the server documentation. . User Action: Replace the faulty memory. Supporting SNMP Trap Data: • sysName, • cpqHoTrapFlags Supporting SNMP Trap Description: "The Advanced Memory Protection - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 90
: The temperature status has been set to OK. The server's temperature has returned to the normal operating range. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "Temperature has returned to normal range." NT Event ID: 1085 (Hex)0xc435043d (cpqsvmsg.dll) Log - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 91
: The CPU fan status has been set to failed. A processor fan is not operating normally. The server is shut down. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "CPU fan has failed. Server will be shutdown." NT Event ID: 1089 (Hex)0x44350441 (cpqsvmsg.dll) Log - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 92
CPU fan status has been set to OK. Any previously non-operational processor fans have returned to normal operation. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "CPU fan is now OK." NT Event ID: 1090 (Hex)0x44350442 (cpqsvmsg.dll) Log Severity: Information - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 93
- 6028 in CPQHLTH.MIB Symptom: The fault tolerant power supply sub-system condition has been set to degraded. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "The server power supply status has become degraded." NT Event ID: 1108 (Hex)0x84350454 (cpqsvmsg - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 94
OS has detected an error in the Remote Insight/ Integrated Lights-Out interface. The firmware is not responding. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "Server [sysName], Remote Insight/Integrated Lights-Out interface error." NT Event ID: 1112 (Hex - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 95
Replace the access panel and be sure that it is installed properly. Verify that the system is working properly. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "Hood is removed from unit." NT Event ID: 1116 (Hex)0x8435045c (cpqsvmsg.dll) Log Severity: Warning - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 96
9010 in CPQSM2.MIB Symptom: External Power Cable Disconnected. The Remote Insight external power cable has been disconnected. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "Remote Insight external power cable disconnected." NT Event ID: 1118 (Hex)0x4435045e - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 97
The fault tolerant power supply condition has been set to failed for the specified chassis and bay location. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeFltTolPowerSupplyChassis • cpqHeFltTolPowerSupplyBay • cpqHeFltTolPowerSupplyStatus • cpqHeFltTolPowerSupplyModel Server agents 97 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 98
MIB Symptom: The Fault Tolerant Power Supplies have lost redundancy for the specified chassis. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeFltTolPowerSupplyChassis Supporting SNMP Trap Description: "The Power Supplies are no longer redundant on Chassis [cpqHeFltTolPowerSupplyChassis - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 99
Fan condition has been set to degraded for the specified chassis and fan. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeFltTolFanChassis • cpqHeFltTolFanIndex Supporting SNMP Trap Description: "The Fan Degraded on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex]." NT Event - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 100
Fault Tolerant Fan has been inserted into the specified chassis and fan location. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeFltTolFanChassis • cpqHeFltTolFanIndex Supporting SNMP Trap Description: "The Fan Inserted on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex]." NT - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 101
. The server's temperature has returned to the normal operating range. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeTemperatureChassis • cpqHeTemperatureLocale Supporting SNMP Trap Description: "Temperature Normal on Chassis [cpqHeTemperatureChassis], Location [cpqHeTemperatureLocale - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 102
in CPQHLTH.MIB Symptom: The DC-DC Power Converters have lost redundancy for the specified chassis. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHePwrConvChassis Supporting SNMP Trap Description: "The Power Converters are no longer redundant on Chassis [cpqHePwrConvChassis]." NT Event - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 103
Plug Slot Board has been removed from the specified chassis and slot. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSiHotPlugSlotChassis • cpqSiHotPlugSlotIndex Supporting SNMP Trap Description: "Hot Plug Slot Board Removed from Chassis [cpqSiHotPlugSlotChassis], Slot - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 104
rack name change to be propagated throughout the entire rack. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackSerialNum • cpqRackTrapSequenceNum Supporting SNMP Trap Description: "The rack name has changed to [cpqRackName]." NT Event ID - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 105
trap indicates that an enclosure has been inserted into the rack. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureModel • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureSparePartNumber - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 106
fans are working properly and that air flow in the rack has not been blocked. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureTempLocation • cpqRackCommonEnclosureSparePartNumber - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 107
that an enclosure temperature sensor has returned to normal. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureTempLocation • cpqRackCommonEnclosureSparePartNumber - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 108
the enclosure overheating. User Action: Replace the fan as soon as possible. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureFanLocation • cpqRackCommonEnclosureFanSparePartNumber - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 109
CPQRACK.MIB Symptom: The enclosure fan has been removed. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureFanLocation • cpqRackCommonEnclosureFanSparePartNumber - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 110
indicates that a power supply has failed. User Action: Replace the power supply as soon as possible. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackPowerSupplyEnclosureName • cpqRackPowerSupplySerialNum • cpqRackPowerSupplyPosition • cpqRackPowerSupplyFWRev - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 111
to OK. This trap indicates that a power supply has returned to normal operation. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackPowerSupplyEnclosureName • cpqRackPowerSupplySerialNum • cpqRackPowerSupplyPosition • cpqRackPowerSupplyFWRev - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 112
MIB Symptom: The power supply has been removed. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • MIB Symptom: The power supply has been inserted. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 113
Symptom: The rack power supply detected an input line voltage problem. User Action: Check the power input for the power supply or replace any failed power supplies as soon as possible. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackPowerSupplyEnclosureName - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 114
power supplies as soon as possible to return the system to a redundant state. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackPowerEnclosureName • cpqRackCommonEnclosureSparePartNumber • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureTrapSequenceNum - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 115
power on the server blade. User Action: Check power connections or add power supplies. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackServerBladeEnclosureName • cpqRackServerBladePosition • cpqRackServerBladeSparePartNumber • cpqRackCommonEnclosureSerialNum - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 116
was not found. User Action: Check server enclosure connections or add power supplies. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackServerBladeEnclosureName • cpqRackServerBladePosition • cpqRackServerBladeSparePartNumber • cpqRackCommonEnclosureSerialNum - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 117
- 22026 in CPQRACK.MIB Symptom: Server power on via manual override. The server blade was powered on by a manual override. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackServerBladeEnclosureName • cpqRackServerBladePosition - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 118
has been removed from the enclosure. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • The server blade has been inserted into the enclosure. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 119
• cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description: "Power subsystem not load balanced in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName]." NT Event ID: 1173 (Hex)0x84350495 (cpqsvmsg.dll) Log Severity: Warning (2) Event Title: Power Subsystem DC Power Problem Log - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 120
• cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureSparePartNumber • cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description: "Power subsystem DC power problem in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName]." NT Event - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 121
number of power enclosures has been exceeded. User Action: Remove the extra power enclosure. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureTrapSequenceNum Server agents 121 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 122
is currently in the process of being reset because of a firmware update or some other event. User action: None Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "The Management processor is in the process of being reset." NT Event ID: 1180 (Hex) 0x0435049c - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 123
in CPQSTDEQ.MIB Symptom: The USB key is attached to the server. User Action: None required. Supporting SNMP Trap Data: • sysName, • cpqHoTrapFlags • cpqSeUSBDeviceType • cpqSeUSBDeviceName Supporting SNMP Trap Description: This trap is sent when a USB storage device has been attached. Symbolic Name - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 124
the software support drivers, or running the Emergency Repair procedure may correct this error. Event identifier: cpqsvmsg.dll - 1544 (Hex)0x84350608 (Service Event) Server Agents package to correct this error. Event identifier: cpqsvmsg.dll - 1796 (Hex)0x84350704 (Service Event) Server agents 124 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 125
is older than the other components of the Server Agents. Reinstall the entire Server Agents package to correct this error. Event identifier: cpqsvmsg.dll - 1800 (Hex)0x84350708 (Service Event) Log Severity: Warning (2) Log Message: Unable to read security configuration information. SNMP sets have - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 126
.SYS) to be installed. Install the driver from the latest Software Support for Windows. If you do not have a Remote Insight Board in contains the error code. Event identifier: cpqsvmsg.dll - 5633 (Hex)0x84351601 (Service Event) Log Severity: Warning (2) Log Message: The Rack And Enclosure MIB Agent - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 127
MIB Agent could not create its main thread of execution. The data contains the error code. Event identifier: cpqsvmsg.dll - 5641 (Hex)0x84351609 (Service Event) Log Severity: Warning (2) Log Message: The Rack And Enclosure MIB Agent main thread did not terminate properly. The data contains the error - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 128
Rack And Enclosure MIB Agent could not get the system type. The data contains the error code. Event identifier: cpqsvmsg.dll - 5682 (Hex)0x84351632 (Service Event) Log Severity: Warning (2) Log Message: The Rack And Enclosure MIB Agent could not set the variable because it is unsupported. The data - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 129
Agent detected an error. The insertion string is: %1. The data contain the error code. Event identifier: cpqnimsg.dll - 257 (Hex)0x84350101 (Service Event) Log Severity: Warning (2) Log Message: Unable to allocate memory. This indicates a low memory condition. Rebooting the system will correct this - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 130
be caused by an improperly installed adapter. Removing and reinstalling the device may correct the problem. The data contain the error code. Event identifier: cpqnimsg.dll - 272 (Hex)0x84350110 (Service Event) Log Severity: Warning (2) Log Message: Failure in driver %1. This error can be caused by - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 131
: Warning (2) Log Message: The NIC Management Agent cannot generate Traps due to a communication problem with the NIC SNMP extension agent. Event identifier: cpqnimsg.dll - 275 (Hex)0x44350113 (Service Event) Log Severity: Information (1) Log Message: Communication with the NIC SNMP extension agent - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 132
log an event to the IML failed. The IML log may be full. Clearing the IML log may correct this problem. Event identifier: cpqnimsg.dll - 298 (Hex)0xc435012a (Service Event) Log Severity: Error (3) Log Message: A fatal error occurred during Virus Throttle WMI event processing. Virus Throttle related - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 133
running. Starting WMI service or NIC agent might solve this problem. Event identifier: cpqnimsg.dll - 299 (Hex)0x8435012b (Service Event) Log Reinstall the entire Insight Agents package to correct this error. Event identifier: cpqnimsg.dll - 1028 (Hex)0x84350404 (Service Event) Log Severity: Warning - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 134
by an invalid or missing configuration or by a corrupt registry. Reinstalling the Insight Agents may correct this problem. Event identifier: cpqnimsg.dll - 1033 (Hex)0x44350409 (Service Event) Log Severity: Information (1) Log Message: The SNMP Insight Agent will allow SNMP sets. Event identifier - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 135
a trap. This can be caused by a failure in the Remote Access Service or by a missing or invalid configuration. Use the Insight Agent control panel to Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP Trap Data: • sysName NIC agents 135 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 136
cable that was unplugged. User Action: None required. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP Trap Data: • sysName NIC agents 136 - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 137
a faulty cable or connecting a cable that was disconnected. User Action: None required. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqNicIfPhysAdapterSlot • cpqNicIfPhysAdapterPort • cpqSiServerSystemId • cpqNicIfPhysAdapterStatus • cpqSePciSlotBoardName • cpqNicIfPhysAdapterPartNumber - HP ProLiant BL25p | Microsoft Windows Event ID and SNMP Traps Reference Guide fo - Page 138
to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqNicIfPhysAdapterSlot • cpqNicIfPhysAdapterPort • cpqSiServerSystemId • cpqNicIfPhysAdapterStatus • cpqSePciSlotBoardName
Microsoft Windows Event ID and SNMP Traps
Reference Guide
For use with SmartStart version 8.25
Part number: 347870-009
Ninth edition: June 2009