HP ProLiant DL320e HP ProLiant DL320e Gen8 Server User Guide

HP ProLiant DL320e Manual

HP ProLiant DL320e manual content summary:

  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 1
    HP ProLiant DL320e Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. This document is intended for experienced IT professionals or end-users with no or prior hardware setup experience. HP assumes you are
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 2
    to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 3
    header...12 System board LED definitions ...12 Drive numbering ...13 Drive LED definitions ...13 FBWC module LED definitions...14 Fan locations ...15 T-10/T-15 Torx screwdriver ...16 Operations...17 Power up the server ...17 Power down the server...17 Extend the server from the rack ...17 Remove the
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 4
    power supply cabling...61 Software and configuration utilities 62 Server mode ...62 Server QuickSpecs ...62 HP iLO Management Engine ...62 HP iLO ...62 Intelligent Provisioning...64 HP Insight Remote Support software 66 Scripting Toolkit ...66 HP Service Pack for ProLiant ...67 HP Smart Update
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 5
    ...72 Drivers ...72 Software and firmware...72 Version control ...72 HP Operating Systems and Virtualization Software Support for ProLiant Servers 73 Change control and proactive notification 73 Troubleshooting ...74 Troubleshooting resources ...74 System battery replacement...75 Regulatory
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 6
    Support and other resources ...88 Before you contact HP...88 HP contact information ...88 Customer Self Repair ...88 Acronyms and abbreviations...96 Documentation feedback ...100 Index...101 Contents 6
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 7
    identification Front panel components • Four-bay LFF drive model Item 1 2 3 4 Description Optical drive Serial label pull tab USB connectors LFF drives • Eight-bay SFF drive model Item 1 2 3 4 Description Optical drive USB connectors Serial label pull tab SFF drives Component identification 7
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 8
    is on. Flashing green = Waiting for power. Amber = System is in standby, but power is still applied. Off = Power cord is not attached or power supply failed. Green = System is on and system health is normal. Flashing amber = System health is degraded. Flashing red = System health is critical. Off
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 9
    1)* Slot 1 PCIe x8 (4, 1)* Power supply 1 Power supply 2 Dedicated iLO management port (optional) UID LED button Serial connector Video connector USB connectors NIC 1/shared iLO management connector NIC connector 2 * For more information on the riser board slots supported by the onboard PCI riser
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 10
    connector Fan connector 4 Fan connector 3 System battery Fan connector 2 Discovery service connector Fan connector 1 24-pin power supply connector 26-pin RPS connector Processor socket DIMM slots TPM connector Dedicated iLO module connector * For more information on the riser board slots supported
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 11
    numbered sequentially (1 through 4) for the processor. The supported AMP modes use the letter assignments for population guidelines PCIe = iLO security is disabled Off = System configuration can be changed On = System configuration is locked Off = Power-on password is enabled On = Power-on password
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 12
    and/or NVRAM deletes configuration information. Be sure to properly configure the server or data loss could occur. NMI header The NMI header enables administrators to perform a memory dump before performing a hard reset. Crash dump analysis is an essential part of eliminating potential reliability
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 13
    1 failure Power supply 2 failure Auxiliary power Processor error Status Red = Power supply failure Off = Normal Red = Power supply failure Off = Normal Green = Standby power indicator Off = Standby power invalid Yellow = Critical processor error Off = Normal Drive numbering • Four-bay LFF drive
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 14
    4 LED Activity ring Do not remove Drive status Status Flashing blue Definition The drive carrier firmware is being updated or requires an update. Rotating green Drive activity Off No drive activity Solid white Off Do not remove the drive. Removing the drive causes one or more of the logical
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 15
    that has not yet been written to the drives. A backup is in progress. The current backup is complete with The current backup failed, and data has been lost. A power error occurred during the previous or current boot. Data may be but power fluctuations occurred during the backup. The cache module
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 16
    T-10/T-15 Torx screwdriver The server includes a T-10/T-15 Torx screwdriver located beside the capacitor pack holder. Use the screwdriver to loosen screws during hardware configuration procedures. Component identification 16
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 17
    , you can use this method to force a shutdown. • Use a virtual power button selection through iLO. This method initiates a controlled remote shutdown of applications and the OS before the server enters standby mode. Before proceeding, verify the server is in standby mode by observing that the system
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 18
    from the rack. To extend the server from an HP, Compaq-branded, Telco, or third-party rack: 1. Power down the server (on page 17). 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Disconnect all peripheral cables. WARNING: To
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 19
    the rack. To remove the server from an HP, Compaq-branded, Telco, or third-party rack: 1. Power down the server (on page 17). 2. Disconnect all peripheral cables and power cords from the server rear panel. 3. Extend the server from the rack (on page 17). 4. Remove the server from the rack. For more
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 20
    . If the server supports hot-plug components, minimize the amount of time the access panel is open. To remove the component: 1. Power down the server (on page 17). 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Do one
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 21
    1. Place the air baffle on top of the server. 2. Install the access panel (on page 20). 3. Do one of the following: o Slide the server into the rack. o Install the server into the rack ("Installing the server into the rack" on page 28). 4. Power up the server (on page 17). Remove the PCI riser cage
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 22
    . Install the PCI riser cage CAUTION: To prevent damage to the server or expansion boards, power down the server, and disconnect all power cords before removing or installing the PCI riser cage. 1. Align the PCI riser cage with the guide pin located on the chassis, and then press down the PCI riser
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 23
    2. Tighten the PCI riser cage thumbscrews. 3. Install the access panel (on page 20). 4. Do one of the following: o Slide the server into the rack. o Install the server into the rack ("Installing the server into the rack" on page 28). 5. Power up the server (on page 17). Operations 23
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 24
    by experienced, certified engineers, HP Care Pack services help you keep your servers up and running with support packages tailored specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and software support into a single package. A number of service level options are
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 25
    allow for servicing and adequate rack to the back of another rack or row of racks. HP servers draw in cool air through the front and expel warm air bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). • Side-The clearance between the installed rack
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 26
    power failure. When installing more than one server, you may need to use additional power distribution devices to safely provide power to all devices. Observe the following guidelines: • Balance the server power 364, parts 1 through 7. Furthermore, you must be sure that all power distribution devices
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 27
    surges and voltage spikes and keeps the system in operation during a power failure. CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage. Rack
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 28
    server quick-release levers) • T-10/T-15 Torx screwdriver (on page 16) • Flathead screwdriver (for dedicated iLO hp). Follow the server-specific instructions on the website to install the rack brackets. Use the following information when connecting peripheral cables and power cords to the server
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 29
    or telecommunications connectors into RJ-45 connectors. 3. Connect the power cord to the rear of the server. 4. When using a hot-plug HP CS power supply, use the strain relief clip from the server hardware kit to secure the power cord. 5. Connect the power cord to the power source. Setup 29
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 30
    for an automated solution. For additional system software and firmware updates, download the HP Service Pack for ProLiant from the HP website (http://www.hp.com/go/spp/download). Software and firmware must be updated before using the server for the first time, unless any installed software or
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 31
    and number of hard drives installed. For more information on modifying the controller default settings, see the documentation on the Documentation CD. For more information on automatic configuration, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the iLO Management Engine
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 32
    it with the key provided with the kit. Drive options The server supports up to four non-hot-plug or hot-plug LFF drives and up to eight hot-plug SFF drives. The embedded storage controller supports SATA drive installation only. For SAS drive installation, install the storage controller card and Mini
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 33
    with either a component or a blank. To install the component: 1. Power down the server (on page 17). 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Remove the drive carrier. 4. Remove the two metal brackets from the
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 34
    the drive in the carrier. 6. Install the drive. 7. Connect each power cord to the server. 8. Connect each power cord to the power source. 9. Power up the server (on page 17). 10. Determine the status of the drive from the drive LED definitions (on page 13). Installing a hot-plug drive CAUTION
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 35
    the status of the drive from the drive LED definitions (on page 13). Mini-SAS cable option To connect the cable option: 1. Power down the server (on page 17). 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Do one of the
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 36
    from the rack (on page 17). o Remove the server from the rack (on page 18). 4. Remove the access panel (on page 19). 5. Remove the of the system board towards the front chassis, and then connect the cable to the drive backplane: o Full-height controller connection Hardware options installation 36
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 37
    cables required in this drive configuration. For more information, see "Storage cabling (on page 55)." 11. Install the access panel (on page 20). 12. Do one of the following: o Slide the server into the rack. o Install the server into the rack ("Installing the server into the rack" on page 28). 13
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 38
    see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support/CASAC_RG_en). Upgrade options exist for the integrated array controller. For a list of supported options, see the QuickSpecs on the HP website (http://www.hp.com/support). The server
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 39
    12. Power up the server (on page 17). For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To configure arrays, see the Configuring Arrays on HP Smart
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 40
    o Remove the server from the rack (on page 18). 4. Remove the access panel (on capacitor pack cable towards the front chassis. For more information on the capacitor pack cabling in different drive configurations, see "Storage cabling (on page 55)." 10. Install the capacitor pack: a. Insert the cable
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 41
    Connect each power cord to the power source. 15. Power up the server (on page 17). Optical drive option To install the component: 1. Power down the server (on page 17). 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Do one
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 42
    panel (on page 19). 6. If you are installing the optical drive in an LFF drive model, do the following: a. Thread the optical drive cable through the optical drive bay. b. Connect the cable to the optical drive. 7. Install the optical drive into the bay, and then secure it with the screw: Hardware
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 43
    cable through the cable clip on the front chassis. b. Route the optical drive cable along the side of the system board, and then connect the cable to the system board. c. Connect the four-pin (1x4) power supply cable to the power connector of the optical drive cable. Hardware options installation 43
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 44
    of the following: o Slide the server into the rack. o Install the server into the rack ("Installing the server into the rack" on page 28). 12. Connect each power cord to the server. 13. Connect each power cord to the power source. 14. Power up the server (on page 17). Memory options Hardware options
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 45
    for Gen8 servers, authenticates and unlocks certain features available only on HP Qualified memory and verifies whether installed memory has passed HP qualification and test processes. Qualified memory is performance-tuned for HP ProLiant and BladeSystem servers and provides future enhanced support
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 46
    latest supported memory information, see the QuickSpecs on the HP website (http://h18000.www1.hp.com/products/quickspecs/ProductBulletin.html). At the website, choose the geographic region, and then locate the product by name or product category. Single-rank and dual-rank DIMMs DIMM configuration
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 47
    the Online DDR3 Memory Configuration Tool on the HP website (http://www.hp.com/go/ddr3memory-configurator). Installing a DIMM 1. Power down the server (on page 17). 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Do one of
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 48
    one of the following: o Slide the server into the rack. o Install the server into the rack ("Installing the server into the rack" on page 28). 11. Connect each power cord to the server. 12. Connect each power cord to the power source. 13. Power up the server (on page 17). Expansion board options The
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 49
    Connect each power cord to the server. 13. Connect each power cord to the power source. 14. Power up the server (on page 17). Dedicated iLO management port option To install the component: 1. Power down the server (on page 17). 2. Remove all power: a. Disconnect each power cord from the power source
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 50
    iLO management module. 7. Install the access panel (on page 20). 8. Do one of the following: o Slide the server into the rack. o Install the server into the rack ("Installing the server into the rack" on page 28). 9. Connect each power cord to the server. 10. Connect each power cord to the power
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 51
    : If the iLO RBSU settings are reset to the default values, access to the machine will be lost. Access the physical machine, and then set the Network Interface Adapter field to ON. HP Trusted Platform Module option Use these instructions to install and enable a TPM on a supported server. This
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 52
    hot surfaces, allow the drives and the internal system components to cool before touching them. To install the component: 1. Power down the server (on page 17). 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Do one of the
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 53
    power cord to the server. 10. Connect each power cord to the power source. 11. Power up the server (on page 17). Retaining the recovery key/password The recovery key/password is generated away from the server. • Do not save the recovery key/password on the encrypted hard drive. Enabling the Trusted
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 54
    OS. For OS-specific instructions, see the OS documentation. CAUTION: When a TPM is installed and enabled on the server, data access is locked if you fail to follow the proper procedures for updating the system or option firmware, replacing the system board, replacing a hard drive, or modifying OS
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 55
    pack cabling is only supported in Smart Array controller options that support FBWC installation. Four-bay LFF non-hot-plug drive cage cabling • Mini-SAS cable connected to the system board Item 1 2 Description Power cable 700-mm Mini-SAS cable for non-hot-plug drive configuration Cabling 55
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 56
    • Mini-SAS cable connected to a storage controller in the full-height expansion slot Item 1 2 3 Description Power cable Capacitor pack cable 700-mm Mini-SAS cable for non-hot-plug drive configuration • Mini-SAS cable connected to a storage controller in the low-profile expansion slot Item 1 2 3
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 57
    Four-bay LFF hot-plug drive cage cabling • Mini-SAS cable connected to the system board Item Description 1 Power cable 2 560-mm Mini-SAS cable • Mini-SAS cable connected to a storage controller in the full-height expansion slot Item 1 2 3 Description Power cable Capacitor pack cable 890-mm
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 58
    Power cable Capacitor pack cable 890-mm Mini-SAS cable Eight-bay SFF hot-plug drive cage cabling • Mini-SAS cables connected to a storage controller in the full-height expansion slot Item 1 2 Description 560-mm Mini-SAS cable 700-mm Mini-SAS cable for hot-plug drive configuration Cabling
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 59
    Item Description 3 Power cable 4 Capacitor pack cable Optical drive cabling • LFF drive cage model Item 1 2 Description Optical drive power cable Optical drive SATA cable • SFF drive cage model Cabling 59
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 60
    Item 1 2 Description Optical drive power cable Optical drive SATA cable Power supply cabling Nonredundant power supply cabling Item 1 2 Description 24-pin power supply cable 4-pin power supply cable Cabling 60
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 61
    supply cabling Item 1 2 3 Description 24-pin power supply cable 26-pin RPS cable 4-pin power supply cable CAUTION: The default and redundant power supplies in the server must have the same output power capacity. Verify that all power supplies have the same part number and label color. The system
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 62
    supporting the complete lifecycle of the server, from initial deployment through ongoing management. HP iLO The iLO subsystem is a standard component of selected HP ProLiant servers that simplifies initial server setup, server health monitoring, power and thermal optimization, and remote server
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 63
    • Easy export and upload to Service and Support The HP Active Health System monitors and records changes in the server hardware and system configuration. The Active Health System assists in diagnosing problems and delivering rapid resolution when server failures occur. The Active Health System
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 64
    packaging changes have taken place with HP ProLiant Gen8 servers: SmartStart CDs and the Smart Update Firmware DVD will no longer ship with these new servers. Instead, the deployment capability is embedded in the server as part of HP iLO Management Engine's Intelligent Provisioning. Intelligent
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 65
    troubleshooting capabilities to assist IT administrators who verify server installations, troubleshoot problems, and perform repair validation. HP configuration information, including array setup and disk partitioning, and erases all connected hard drives completely. Refer to the instructions for
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 66
    . Notifications may be sent to your authorized HP Channel Partner for on-site service, if configured and available in your country. The software is available in two variants: • HP Insight Remote Support Standard: This software supports server and storage devices and is optimized for environments
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 67
    Enables direct update of BMC firmware (HP iLO) For more information about HP SUM and to access the HP Smart Update Manager User Guide, see the HP website (http://www.hp.com/go/hpsum/documentation). HP ROM-Based Setup Utility RBSU is a configuration utility embedded in ProLiant servers that performs
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 68
    • Configuring memory options • Language selection For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support/rbsu). Using RBSU To use RBSU, use the following keys: • To access RBSU, press the F9 key during power-up
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 69
    • Runs as a local application or remote service accessed through the HP System Management Homepage • Supports online array capacity expansion, logical drive extension, assignment of online spares, and RAID or stripe size migration • Suggests the optimum configuration for an unconfigured system • For
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 70
    , see the HP Smart Array Controllers for HP ProLiant Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support/CASAC_RG_en
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 71
    Smart Array Controllers for HP ProLiant Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support/CASAC_RG_en). ROMPaq utility
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 72
    Software and firmware should be updated before using the server for the first time, unless any installed software or components require an older version. For system software and firmware updates, download the SPP ("HP Service Pack for ProLiant" on page 67) from the HP website (http://www.hp.com/go
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 73
    Manager User Guide, the HP Version Control Agent User Guide, and the HP Version Control Repository User Guide on the HP website (http://www.hp.com/go/hpsim). HP Operating Systems and Virtualization Software Support for ProLiant Servers For information about specific versions of a supported operating
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 74
    ) • Simplified Chinese (http://www.hp.com/support/ProLiant_TSG_v1_sc) The HP ProLiant Gen8 Troubleshooting Guide, Volume II: Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades. To view the
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 75
    dispose of in fire or water. • Replace only with the spare designated for this product. To remove the component: 1. Power down the server (on page 17). 2. Remove all power: a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Do one of the following
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 76
    to its default configuration. After replacing the battery, reconfigure the system through RBSU. To replace the component, reverse the removal procedure. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. System battery
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 77
    to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 78
    O. Box 692000, Mail Stop 530113 Houston, Texas 77269-2000 • 1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls may be 77269-2000 • 1­281-514-3333 To identify this product, refer to the part, series, or model number found on the product. Modifications The FCC requires the
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 79
    2004/108/EC • Ecodesign Directive 2009/125/EC, where applicable CE compliance of this product is valid if powered with the correct CE-marked AC adapter provided by HP. Compliance with these directives implies conformity to applicable harmonized European standards (European Norms) that are listed in
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 80
    more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Japanese notice BSMI notice Korean notice Class A equipment Regulatory compliance notices 80
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 81
    is for applicable products only. Ukraine notice Laser compliance This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 82
    disposal, use the public collection system or return them to HP, an authorized HP Partner, or their agents. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. Taiwan battery recycling notice The Taiwan EPA requires dry
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 83
    Acoustics statement for Germany (Geräuschemission) Schalldruckpegel LpA < 70 dB(A) Zuschauerpositionen (bystander positions), Normaler Betrieb (normal operation) Nach ISO 7779:1999 (Typprüfung) Regulatory compliance notices 83
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 84
    tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity or assistance with product installation, contact
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 85
    models with SFF drive cage 69.90 cm (27.50 in) Width 43.46 cm (17.11 in) Weight (approximate range) 10.00 kg to 24.00 kg (22.00 lb to 53.00 lb) Power supply specifications Depending on installed options, the server is configured with one of the following power supplies: • HP 350 W 1U Factory
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 86
    % load Not less than 82% at 20% load 400 W at 100 V to 120 V AC input 400 W at 200 V to 240 V AC input HP 460 W CS Gold Hot-plug Power Supply (92% efficiency) Specification Value Input requirements - Rated input voltage Rated input frequency 100 V AC-240 V AC 50 Hz-60 Hz Rated input current
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 87
    output 460 W at 200 V to 240 V AC output Hot-plug power supply calculations For hot-plug power supply specifications and calculators to determine electrical and heat loading for the server, refer to the HP Enterprise Configurator website (http://h30099.www3.hp.com/configurator/). Specifications 87
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 88
    .hp.com/services/cache/10950-0-0-225-121.html). Customer Self Repair HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service Support
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 89
    a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts: • Mandatory-Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. • Optional-Parts for
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 90
    comportare la fatturazione del ricambio da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. Support
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 91
    ügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen : componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendr
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 92
    propio cliente de HP, póngase en HP siguiente (http://www.hp.com/go/selfrepair). Customer Self Repair Veel onderdelen in HP HP (of een HP Service HP Service HP Service Partner om via de telefoon technische ondersteuning te ontvangen. HP stico, a HP (ou fornecedores/parceiros de serviço da HP) concluir
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 93
    transportadora/serviço postal a ser utilizado. Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP (http://www.hp.com/go/selfrepair). Support and other resources 93
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 94
    Support and other resources 94
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 95
    Support and other resources 95
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 96
    Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility AMP Advanced Memory Protection ASR Automatic Server Recovery BMC baseboard management controller BSMI Bureau of Standards, Metrology and Inspection CE Conformité Européenne (European Conformity) CSA Canadian Standards
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 97
    Slot (power supply) HP SIM HP Systems Insight Manager HP SUM HP Smart Update Manager IEC International Electrotechnical Commission iLO Integrated Lights-Out IML Integrated Management Log ISO International Organization for Standardization LFF large form factor LRDIMM load reduced dual in-line memory
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 98
    RDIMM registered dual in-line memory module RDP Rapid Deployment Pack RF radio frequency RFI radio frequency interference RPS redundant power supply SAS serial attached SCSI SATA serial ATA SD Secure Digital SFF small form factor SPP HP Service Pack for ProLiant Acronyms and abbreviations 98
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 99
    TMRA recommended ambient operating temperature TPM Trusted Platform Module UDIMM unregistered dual in-line memory module UID unit identification USB universal serial bus VCA Version Control Agent VCRM Version Control Repository Manager Acronyms and abbreviations 99
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 100
    that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:[email protected]). Include the document title and part number, version number, or the URL when submitting your feedback. Documentation feedback 100
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 101
    88 auto-configuration process 68 Automatic Server Recovery (ASR) 71 B Basic Input/Output System (BIOS) battery 75, 82 BIOS (Basic Input/Output System) BIOS upgrade 62, 71 boot options 30, 69 BSMI notice 80 buttons 7 62, 71 62, 71 C cable shielding 78 cables 55, 78 cabling 55 cabling, drive 55
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 102
    status of 13 hard drives, installing 32, 33 hardware options 28, 32 hardware options installation 32 health driver 71 help resources 88 HP Insight Diagnostics 65 HP Insight Remote Support software 66 HP Service Pack for ProLiant 62, 67 HP Smart Update Manager overview 62, 67 HP technical support 88
  • HP ProLiant DL320e | HP ProLiant DL320e Gen8 Server User Guide - Page 103
    mode 62 shipping carton contents 28 site requirements 25 Smart Update Manager 62, 67 specifications, environmental 85 specifications, server 85 SPP 67 static electricity 84 storage controller 35 support 88 supported operating systems 73 system battery 75 system board components 10 system board
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103

HP ProLiant DL320e Gen8 Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. This document is intended for experienced
IT professionals or end-users with no or prior hardware setup experience. HP assumes you are qualified in the servicing of computer equipment and
trained in recognizing hazards in products with hazardous energy levels.
Part Number: 682822-001
September 2012
Edition: 1