HP ProLiant ML330e Microsoft Windows Event ID and SNMP Traps Reference Guide f
HP ProLiant ML330e Manual
View all HP ProLiant ML330e manuals
Add to My Manuals
Save this manual to your list of manuals |
HP ProLiant ML330e manual content summary:
- HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 1
Microsoft Windows Event ID and SNMP Traps Reference Guide For use with SmartStart version 8.25 Part number: 347870-009 Ninth edition: June 2009 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 2
HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP 212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 3
-774 ...29 Event Identifiers 1061-1098 ...32 Event Identifiers 1101-1199 ...38 Event Identifiers 1200-1294 ...64 Event Identifiers 1343-4613 ...77 Server agents...82 Event Identifiers 256-774 ...82 Event Identifiers 1024-1092 ...85 Event Identifiers 1103-1183 ...93 Event Identifiers 1539-3352 ...124 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 4
generated by the HP Insight Management Agents for Servers for Windows®. Each event entry has the corresponding SNMP trap number used by the agents. Other information on the events in this document includes Event Severity, Event Message, Event Message Source, Event Symptom, and Supporting SNMP Trap - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 5
: • In the United States, see the HP US service locator webpage, http://www.hp.com/service_locator. • In other locations, see the HP website, http://www.hp.com. For HP technical support: • In North America: ○ Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 6
string is: %1. The data contains the error code. Event identifier: cpqhsmsg.dll - 257 (Hex)0x84350101 (Service Event) Log Severity: Warning (2) Log Message: The Foundation Agents service could not allocate memory. The data contains the error code. Event identifier: cpqhsmsg.dll - 258 (Hex)0x84350102 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 7
invalid state for agent "%1". The data contains the state. Event identifier: cpqhsmsg.dll - 269 (Hex)0x8435010d (Service Event) Log Severity: Warning (2) Log Message: The Foundation Agents service could not stop agent "%1". The data contains the error code. Event identifier: cpqhsmsg.dll - 270 (Hex - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 8
. Please install the SNMP service to enabled remote management of the server. Event identifier: cpqhsmsg.dll - 768 (Hex)0x84350300 (Service Event) Log Severity: Warning (2) Log Message: The Host Remote Alerter detected an invalid data type within an alert definition. Event identifier: cpqhsmsg.dll - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 9
error code. Event identifier: cpqhsmsg.dll - 774 (Hex)0xc4350306 (Service Event) Log Severity: Error (3) Log Message: The Host Remote Alerter .MIB Symptom: Generic trap. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHoGenericData Supporting SNMP Trap Description: "[cpqHoGenericData]" - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 10
within the variable list are those of the alarm entry that generated this trap. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqMeAlarmVariable • cpqMeAlarmSampleType • cpqMeAlarmValue • cpqMeAlarmFallingThreshold • cpqMeAlarmOwner • cpqMeAlarmSeverity • cpqMeAlarmExtendedDescription - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 11
Data: • sysName • cpqHoTrapFlags • cpqHoSwRunningTrapDesc Supporting SNMP Trap Description: "[cpqHoSwRunningTrapDesc]" NT Event ID: 1167 (Hex)0x8435048f (cpqhsmsg.dll) Log Severity: Warning (2) Log Message: The cluster resource %4 has become degraded. SNMP Trap: cpqClusterResourceDegraded - 15005 in - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 12
time the condition of a cluster network becomes degraded. User Action: Make a note of the cluster network name, and then check the network for the cause of the degraded condition. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqClusterNetworkName Supporting SNMP Trap Description: "Cluster - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 13
• cpqHoTrapFlags • cpqClusterNetworkName Supporting SNMP Trap Description: "Cluster network [cpqClusterNetworkName] has failed." NT Event ID:1171 (Hex)0x84350493 (cpqhsmsg.dll) Log Severity: Warning (2) Log Message: The cluster service on %4 has become degraded. SNMP Trap: cpqClusterNodeDegraded - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 14
- 19003 in CPQWINOS.MIB Symptom: The Cache CopyReadHits performance property is set to degraded. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqOsCacheIndex • cpqOsCacheInstance • cpqOsCacheCopyReadHitsPercent Supporting SNMP Trap Description: "The Cache performance property is - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 15
Symptom: The PagingFile Usage performance property is set to degraded. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqOsPagingFileIndex • cpqOsPagingFileInstance • cpqOsPageFileUsagePercent Supporting SNMP Trap Description: "The PagingFile performance instance, [cpqOsPagingFileInstance - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 16
LogicalDisk BusyTime performance property is set to degraded. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqOsLogicalDiskIndex • cpqOsLogicalDiskInstance • cpqOsLogicalDiskBusyTimePercent Supporting SNMP Trap Description: "The LogicalDisk performance instance, [cpqOsLogicalDiskInstance - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 17
sets have been disabled. Event identifier: cpqhsmsg.dll - 1803 (Hex)0xc435070b (Service Event) Log Management configuration settings. Use the Network control panel to verify the Service may correct this error. For more information, see the Management Agents Asynchronous Management documentation - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 18
the registry sub-key: "%1". This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 2051 (Hex)0x84350803 (Service Event) Log Severity: Warning (2) Log Message: Unable to read from the registry. This error - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 19
: Unable to acquire the current process list. This error can be caused by a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 2101 (Hex)0x84350835 (Service Event) Log Severity: Warning (2) Log Message: Unable to acquire the CPU performance data. This - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 20
configured to allow SNMP requests from "localhost". 2) Be sure that there is an adequate amount of free memory. Event identifier: cpqhsmsg.dll - 2356 (Hex)0x84350934 (Service Event) Log Severity: Warning (2) Log Message: "%1". The data contains the error code. Event identifier: cpqhsmsg.dll - 2357 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 21
the registry sub-key. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 3073 (Hex)0x84350c01 (Service Event) Log Severity: Warning (2) Log Message: Could not create the registry sub-key: "%1". This - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 22
the registry sub-key. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 3842 (Hex)0x84350f02 (Service Event) Log Severity: Warning (2) Log Message: Could not write the registry sub-key: "%1". This - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 23
Event) Log Severity: Information (1) Log Message: Resource status is online. Event identifier: cpqhsmsg.dll - 3861 (Hex)0x44350f15 (Service Event) Log Severity: Information (1) Log Message: Resource status is offline. The resource has failed or was taken offline by a cluster administrator. Event - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 24
caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 3875 (Hex)0x84350f23 (Service Event) Log Severity: Warning (2) Log Message: Could not open enumerated network. The Cluster service may not be running. Try to restart - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 25
the cluster's networks. The Cluster service may not be running. Try to restart the Cluster service. Event Identifiers 4352-4626 Event identifier: cpqhsmsg.dll - 4352 (Hex)0x84351100 (Service Event) Log Severity: Warning (2) Log Message: The External Status MIB Agent could not allocate memory. The - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 26
is configured to allow SNMP requests from "localhost." 2. Be sure that there is an adequate amount of free memory. Event identifier: cpqhsmsg.dll - 4405 (Hex)0x84351135 (Service Event) Log Severity: Warning (2) Log Message: The External Status MIB Agent could not set the variable because it is - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 27
be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqhsmsg.dll - 4623 (Hex)0x8435120f (Service Event) Log Severity: Warning (2) Log Message: The Agent could not access WMI. The WMI support may have not been started or installed - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 28
or may still be in the starting state. Event identifier: cpqhsmsg.dll - 4626 (Hex)0x84351212 (Service Event) Log Severity: Warning (2) Log Message: The Agent failed to process the MOF file to get the data from WMI. Problem with WMI service or MOF file or wrong file paths used. Foundation agents 28 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 29
string is: %1. The data contains the error code. Event identifier: cpqstmsg.dll - 257 (Hex)0x84350101 (Service Event) Log Severity: Warning (2) Log Message: The Storage Agents service could not allocate memory. The data contains the error code. Event identifier: cpqstmsg.dll - 258 (Hex)0x84350102 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 30
load the module "%1". The data contains the error code. Event identifier: cpqstmsg.dll - 265 (Hex)0x84350109 (Service Event) Log Severity: Warning (2) Log Message: The Storage Agents service could get the control function for module "%1". The data contains the error code. Event identifier: cpqstmsg - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 31
by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 526 (Hex)0x8435020e (Service Event) Log Severity: Warning (2) Log Message: Unsupported storage system. The ProLiant storage system %1 is not supported by this version of the - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 32
to get capacity on SCSI drive because SCSI pass through IOCTL failed. Event identifier: cpqstmsg.dll - 768 (Hex)0x84350300 (Service Event) Log Severity: Warning (2) Log Message: The Remote Alerter Agent detected an invalid data type within an alert definition. Event identifier: cpqstmsg.dll - 769 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 33
the agent has detected a change in the status of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current logical drive status. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaLogDrvStatus Supporting SNMP Trap Description: "Status is now [cpqDaLogDrvStatus]." NT - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 34
has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 35
accelerator cache board that has lost battery power. If data was being stored in the accelerator cache memory when the server lost power, that data has been lost. User Action: Verify that no data has been lost. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrSlot • cpqDaCntlrModel - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 36
• cpqHoTrapFlags • cpqScsiCntlrStatus Supporting SNMP Trap Description: "Status is now [cpqScsiCntlrStatus]." NT Event ID: 1069 (Hex)0xc435042d (cpqstmsg.dll) Log Severity: Error (3) Event Title: SCSI Logical Drive Status Change. Log Message: The SCSI logical drive with SCSI target %6 connected to - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 37
• cpqScsiPhyDrvFWRev • cpqScsiPhyDrvSerialNum • cpqScsiPhyDrvOsName Supporting SNMP Trap Description: "Status is the fan status is degraded or failed, replace any failed fans. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxFanStatus Supporting SNMP Trap Description: - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 38
degraded. The agent has detected a temperature status that has been set to degraded. Supporting SNMP Trap Description: "Storage System temperature ok." Event identifier: cpqstmsg.dll - 1098 (Hex)0x4435044a (Service Event) Log Severity: Information (1) Log Message: Drive Array Physical Drive - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 39
%4 has a degraded status. Restore power or replace any failed power supply. SNMP Trap: cpqSs4PwrSupplyDegraded - 8015 in CPQSTSYS.MIB Symptom: A storage system power supply status has been set to degraded. User Action: Restore power or replace any failed storage system power supply. Supporting SNMP - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 40
• cpqSsBoxFltTolPwrSupplyStatus Supporting SNMP Trap Description: "A storage system power supply unit has become degraded." NT Event ID: 1107 (Hex)0xc4350453 (cpqstmsg.dll) Log Severity: Error (3) Event Title: SCSI Tape Drive Status Change. Log Message: The tape drive with SCSI target %6 connected - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 41
information on a component replacement, see the appropriate Maintenance and Service Guide. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqIdeIdentIndex Supporting SNMP Trap Description: "IDE drive [cpqIdeIdentIndex] has become degraded." NT Event ID: 1122 (Hex)0x44350462 (cpqstmsg.dll - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 42
a change in the status of an External Array logical drive. The variable cpqFcaLogDrvStatus indicates the current logical drive status. User Action: If the logical drive status is failed, examine the array for failed drives that need replacement. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 43
status. The variable cpqFcaSpareBusNumber indicates the SCSI bus number associated with this drive. User Action: If the spare drive status is failed, replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqFcaSpareBusNumber • cpqFcaSpareBay - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 44
Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the system lost power, that data has been lost. User Action: Verify that no data has been lost. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 45
Check the storage box and all fibre channel connections for problems. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP Trap Data: • sysName Storage agents 45 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 46
cpqSsPowerSupplyStatus indicates the current status. User Action: If the power supply status is failed, restore power or replace the failed power supply. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqSsPowerSupplyBay • cpqSsPowerSupplyStatus - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 47
cpqSsPowerSupplyUpsStatus Supporting SNMP Trap Description: "Storage system power . User Action: If the temperature status is degraded or failed, shut down the storage system as Library Failed. Log Message: The SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 48
with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 is in a degraded condition. SNMP Trap: cpqTape3LibraryDegraded - 5012 in CPQSCSI.MIB Symptom: Tape Library Degraded. The Insight Agent has detected that an autoloader unit is in a degraded condition. • Supporting SNMP Trap - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 49
with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a closed door and is now operational. SNMP Trap: cpqTape3LibraryDoorClosed - 5014 in CPQSCSI.MIB Symptom: Tape Library Door Closed. The Insight Agent has detected that the door on an autoloader has closed. Supporting SNMP - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 50
Warning (2) Event Title: Drive Array Controller Active. Log Message: The Drive Array Controller in slot %4 problems. If this was the result of a user initiated switchover, no action is required. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrSlot • cpqDaCntlrPartnerSlot Supporting - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 51
connections for problems. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeCntlrWWN • cpqFcTapeCntlrStatus Supporting SNMP Trap on tape controller with world wide name "%4", SCSI bus %5, SCSI target %6, has a new door status of %7. SNMP Trap: cpqFcTapeLibraryDoorStatusChange - - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 52
(cpqstmsg.dll) Log Severity: Warning (2) Event Title: Fibre Channel Tape Drive Status Change. Log Message: The Fibre Channel tape drive on tape controller with world wide name "%4", SCSI bus %5, SCSI target %6, has a new status of %7. SNMP Trap: cpqFcTapeDriveStatusChange - 16011 in CPQFCA - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 53
drive on tape controller with world wide name "%4", SCSI bus %5, SCSI target %6, needs to be replaced. SNMP Trap: cpqFcTapeDriveCleanTapeReplace - 16013 in CPQFCA.MIB Symptom: Fibre Channel Tape Drive problems. If this was the result of a user initiated switchover, no action is required. Supporting - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 54
Supporting SNMP Trap Description: "Status is now [cpqDaTapeLibraryStatus] for the tape library." NT Event ID: 1181 (Hex)0x8435049d (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Tape Library Door Status Change. Log Message: The tape library in slot %4, SCSI bus %5, SCSI target - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 55
Supporting SNMP Trap Description: "Status is now [cpqDaTapeDrvStatus] for a tape drive." NT Event ID: 1183 (Hex)0x8435049f (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Tape Drive Cleaning Required. Log Message: The tape drive in slot %4, SCSI bus %5, SCSI target - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 56
: Drive Array Tape Drive Replace Cleaning Tape. Log Message: The cleaning tape in the tape drive in slot %4, SCSI bus %5, SCSI target %6 Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaTapeDrvCntlrIndex • cpqDaTapeDrvBusIndex • cpqDaTapeDrvScsiIdIndex • cpqDaTapeDrvLunIndex Supporting - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 57
a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status. User Action: If the physical drive status is smartError(3) or failed(4), replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqIdeAtaDiskControllerIndex - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 58
User Action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Status Change. Log Message: An enclosure attached to port %5 of storage system "%4" has a new temperature status of %7. The enclosure model is "%6". SNMP Trap: - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 59
Storage System Power Supply Status Change. Log Message: An enclosure attached to port %5 of storage system "%4" has a new power supply status of %7. The enclosure model is Action: If the power supply status is degraded, restore power or replace the failed power supply. Supporting SNMP Trap Data: - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 60
• cpqTapeLibraryState Supporting SNMP Trap Description: "Status is now [cpqTapeLibraryState]." NT Event ID: 1192 (Hex)0x843504a8 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: SCSI Tape Drive Status Change. Log Message: The tape drive with SCSI target %6 connected to - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 61
that needs to have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqFcTapeDriveCntlrIndex • cpqFcTapeDriveScsiBus • cpqFcTapeDriveScsiTarget • cpqFcTapeDriveScsiLun • cpqFcTapeDriveModel • cpqFcTapeDriveFWRev - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 62
that all cables are connected properly. If the RSO status is secondaryRunningAuto(8) or secondaryRunningUser(9), examine the primary server for failed components. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsChassisName • cpqSsChassisTime • cpqSsChassisRsoStatus • cpqSsChassisIndex - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 63
door is open, close the tape library door. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • Hex)0x843504af (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Controller Status Change. Log Message: The Drive Array Controller in %7 has a new status of %5. SNMP - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 64
that the agent has detected a change in the status of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current logical drive status. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaLogDrvCntlrIndex • cpqDaLogDrvIndex • cpqDaLogDrvStatus - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 65
has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If the physical drive status is failed(3) or predictive Failure(4), replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 66
detected a factory threshold associated with one of the physical drive objects on a drive array has been exceeded. User Action: Replace the physical drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation • cpqDaPhyDrvCntlrIndex • cpqDaPhyDrvIndex • cpqDaPhyDrvBusNumber - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 67
cache memory when the server lost power, that data has been lost. User Action: Verify that no data has been lost. Supporting SNMP Accelerator lost battery power. Data Loss possible." NT Event ID: 1206 (Hex)0x843504b6 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Accelerator - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 68
Supporting SNMP Trap Description: "Status is now [cpqDaTapeLibraryStatus] for the tape library." NT Event ID: 1208 (Hex)0x843504b8 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Tape Library Door Status Change. Log Message: The tape library in %4, SCSI bus %5, SCSI target - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 69
• cpqDaTapeDrvStatus Supporting SNMP Trap Description: "Status is now [cpqDaTapeDrvStatus] for a tape drive." NT Event ID: 1210 (Hex)0x843504ba (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Tape Drive Cleaning Required. Log Message: The tape drive in %4, SCSI bus %5, SCSI target - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 70
Supporting SNMP Trap Description: "Cleaning is needed for the tape drive." NT Event ID: 1211 (Hex)0x843504bb (cpqstmsg.dll) Log Severity: Warning (2) Event Title: Drive Array Tape Drive Replace Cleaning Tape. Log Message: The cleaning tape in the tape drive in %4, SCSI bus %5, SCSI target - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 71
User Action: If the temperature status is degraded or failed, shut down the storage system as cpqSsBoxSerialNumber • cpqSsBoxTempStatus Supporting SNMP Trap Event Title: Storage System Fault Tolerant Power Supply Status Change. Log Message: The fault tolerant power supply in the %6 %7 storage system - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 72
User Action: If the power supply status is degraded, restore power or replace the failed power supply. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxCntlrHwLocation • cpqSsBoxCntlrIndex • cpqSsBoxBusIndex • cpqSsBoxVendor • cpqSsBoxModel • cpqSsBoxSerialNumber • - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 73
that the agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status. User Action: If the spare drive status is failed, replace the drive. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqDaCntlrHwLocation - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 74
Action: If the fan status is degraded or failed, replace any failed fans. Supporting SNMP Trap Data: • sysName • cpqSsBoxTempStatus indicates the current temperature status. User Action: If the temperature status is degraded or failed, shut down the storage system as soon as possible. Be sure - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 75
system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status. User Action: If the power supply status is degraded, restore power or replace the failed power supply. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSsBoxCntlrHwLocation • cpqSsBoxCntlrIndex - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 76
or SATA logical drive. The current logical drive status is indicated in the cpqSasLogDrvStatus variable. Supporting SNMP Trap Data registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 1282 (Hex)0x84350502 (Service Event) Log Severity: - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 77
caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 1294 (Hex)0x8435050e (Service Event) Log Severity: Warning (2) Log Message: Unsupported storage system. The ProLiant storage system %1 is unsupported by this version - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 78
Agents may correct this problem. Event identifier: cpqstmsg.dll - 1803 (Hex)0xc435070b (Service Event) Log Severity: Service or by a missing or invalid configuration. Use the HP Insight Management Agents control panel to verify the Asynchronous Management configuration settings. Use the Network - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 79
Agent could not allocate memory. The data contains the error code. Event identifier: cpqstmsg.dll - 3585 (Hex)0x84350e01 (Service Event) Log Severity: the error code. Event identifier: cpqstmsg.dll - 3591 (Hex)0x84350e07 (Service Event) Log Severity: Warning (2) Log Message: The IDE Agent could not - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 80
the registry subkey. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 4098 (Hex)0x84351002 (Service Event) Log Severity: Warning (2) Log Message: Could not write the registry subkey: "%1". This - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 81
read the registry subkey: "%1". This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqstmsg.dll - 4609 (Hex)0x84351201 (Service Event) Log Severity: Warning (2) Log Message: Could not read the registry subkey. This - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 82
string is: %1. The data contains the error code. Event identifier: cpqsvmsg.dll - 257 (Hex)0x84350101 (Service Event) Log Severity: Warning (2) Log Message: The Server Agents service could not allocate memory. The data contains the error code. Event identifier: cpqsvmsg.dll - 258 (Hex)0x84350102 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 83
not unload the module "%1". The data contains the error code. Event identifier: cpqsvmsg.dll - 272 (Hex)0x84350110 (Service Event) Log Severity: Warning (2) Log Message: The Server Agents service could not create the registry key "%1". The data contains the error code. Event identifier: cpqsvmsg.dll - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 84
Service Event) Log Severity: Information (1) Log Message: The Server Agents service version %1 has started. Event identifier: cpqsvmsg.dll - 401 (Hex)0x44350191 (Service data type within an alert definition. Event identifier: cpqsvmsg.dll - 769 (Hex)0x84350301 (Service Event) Log Severity: Warning - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 85
- 6047 in CPQHLTH.MIB Symptom: Advanced Memory Protection Online Spare Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The Online Spare Memory has been activated. User Action: Schedule server down time to replace the faulty memory. Supporting SNMP Trap Data: • sysName - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 86
SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "The Advanced Memory Protection subsystem has engaged the XOR memory." NT Event ID: 1029 (Hex)0x44350405 (cpqsvmsg.dll) Log Severity: Information (1) Log Message: The Fault Tolerant Power Supply Sub-system has returned to - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 87
: cpqHe5CorrMemReplaceMemModule - 6064 in CPQHLTH.MIB Symptom: Corrected Memory Errors Detected. The errors have been corrected, but the memory module should be replaced. Value 0 for CPU means memory is not processor-based. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeResMem2BoardNum - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 88
is installed correctly, and then re-install the memory board, cartridge, or processor. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeResMem2BoardSlotNum • cpqHeResMem2BoardCpuNum • cpqHeResMem2BoardRiserNum Supporting SNMP Trap Description: "Memory Board or Cartridge Removed from Slot - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 89
Severity: Warning (3) Log Message: The Advanced Memory Protection sub-system has detected a memory fault. The LockStep recovery engine has been activated. For instruction on replacing the faulty memory, see the server documentation. SNMP Trap: cpqHeResilientMemLockStepMemoryEngaged - 6068 in CPQHLTH - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 90
Symptom: The temperature status has been set to degraded. The server's temperature is outside of the normal operating range. The server is shut down if the cpqHeThermalDegradedAction variable is set to shutdown (3). Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHeThermalDegradedAction - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 91
: Warning (2) Log Message: A System Fan Condition has been set to degraded. If the system fan is part of a redundancy group, the system normally. The server is shut down. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "CPU fan has failed. Server will be - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 92
Errors were detected. One or more Power-On-Self-Test errors were detected during server startup. SNMP Trap: cpqHe3PostError - 6027 in CPQHLTH.MIB Symptom: One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process. Supporting SNMP Trap Data: • sysName - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 93
- 6028 in CPQHLTH.MIB Symptom: The fault tolerant power supply sub-system condition has been set to degraded. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "The server power supply status has become degraded." NT Event ID: 1108 (Hex)0x84350454 (cpqsvmsg.dll - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 94
OS has detected an error in the Remote Insight/ Integrated Lights-Out interface. The firmware is not responding. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "Server [sysName], Remote Insight/Integrated Lights-Out interface error." NT Event ID: 1112 (Hex - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 95
degraded. This trap is sent when cpqSeCpuThreshPassed transitions from false to true. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSeCpuSlot • cpqSeCpuSocketNumber Supporting mouse cable has been disconnected. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Server agents 95 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 96
], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev]." NT Event ID: 1123 (Hex)0x84350463 (cpqsvmsg.dll) Log Severity: Warning (2) Log Message: Post Errors were detected. One or more Power-On-Self-Test errors were detected during server startup. SNMP Trap - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 97
Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: "Errors occurred during server restart." NT Event ID: 1124 (Hex)0x84350464 (cpqsvmsg.dll) Log Severity: Warning (2) Log Message: The Fault Tolerant Power Supply Sub-system is in a degraded state. Restore power or replace the failed - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 98
• cpqSiServerSystemId Supporting SNMP Trap Description: "The Power Supply is Failed on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 99
Supporting SNMP Trap Description: "The Power Supply Removed on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay]." NT Event ID: 1129 (Hex)0x84350469 (cpqsvmsg.dll) Log Severity: Warning (2) Log Message: The Fan Sub-system is in a degraded the specified chassis. Server agents 99 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 100
.MIB Symptom: The temperature status has been set to failed in the specified chassis and location. The system is shut down due to this condition. Supporting SNMP Trap Data: • sysName Server agents 100 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 101
: The temperature status has been set to degraded in the specified chassis and location. The server's temperature is outside of the normal operating range. The server is shut down if the cpqHeThermalDegradedAction variable is set to shutdown (3). Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 102
condition has been set to degraded for the specified chassis, slot, and socket. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqHePwrConvChassis • cpqHePwrConvSlot • cpqHePwrConvSocket Supporting SNMP Trap Description: "The Power Converter Degraded on Chassis [cpqHePwrConvChassis], Slot - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 103
has failed to power up in the specified chassis and slot. User Action: Be sure the board and all cables are installed correctly, and that the board type and revision are the same as the replaced board. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqSiHotPlugSlotChassis Server agents 103 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 104
utility has changed the name of the rack. Each of the server blades in each of the enclosure within the rack is updated to reflect the new rack name None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackSerialNum • cpqRackTrapSequenceNum Supporting SNMP Trap - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 105
SNMP Trap: cpqRackEnclosureInserted - 22004 in CPQRACK.MIB Symptom: The enclosure has been inserted. This trap indicates that an enclosure has been inserted into the rack. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 106
Action: Shut down the enclosure and possibly the rack as soon as possible. Be sure that all fans are working properly and that air flow in the rack has not been blocked. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName Server agents 106 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 107
This trap indicates that an enclosure fan has failed and that no other fans in the redundant fan group are operating. This may result in the enclosure overheating. User Action: Replace the fan as soon as possible. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName Server agents 107 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 108
Symptom: The enclosure fan status has been set to degraded. This trap indicates that an enclosure fan has failed but that other fans in the redundant fan group are still operating. This may result in the enclosure overheating. User Action: Replace the fan as soon as possible. Supporting SNMP Trap - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 109
(1) Event Title: Rack Enclosure Fan Inserted Log Message: The enclosure fan has been inserted. SNMP Trap: cpqRackEnclosureFanInserted - 22012 in CPQRACK.MIB Symptom: The enclosure fan has been inserted. User Action: None. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Server agents 109 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 110
Supporting SNMP Trap Description: "The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been set to failed." NT Event ID: 1156 (Hex)0x84350484 (cpqsvmsg.dll) Log Severity: Warning (2) Event Title: Rack Power Supply Degraded - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 111
• cpqRackPowerSupplySparePartNumber • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description: "The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been set to degraded." NT Event ID - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 112
• cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description: "The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been inserted." NT Event ID: 1160 (Hex)0x84350488 (cpqsvmsg.dll) Log Severity: Warning (2) Server agents - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 113
Supporting SNMP Trap Description: "The rack power supply detected an input line voltage problem in power supply [cpqRackPowerSupplyPosition], enclosure [cpqRackPowerSupplyEnclosureName], rack [cpqRackName]." NT Event ID: 1162 (Hex)0x8435048a (cpqsvmsg.dll) Server - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 114
• cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description: "The server shutdown due to lack of power blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName]." NT Event ID: 1164 (Hex)0xc435048c (cpqsvmsg.dll) Server agents 114 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 115
- 22022 in CPQRACK.MIB Symptom: Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User Action: Check power connections or add power supplies. Supporting SNMP Trap Data: • sysName - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 116
- 22024 in CPQRACK.MIB Symptom: Inadequate power to power on. There is not enough power to power on the server blade. The server enclosure micro-controller was not found. User Action: Check server enclosure connections or add power supplies. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 117
Supporting SNMP Trap Description: "Inadequate power to power on blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName]." NT Event ID: 1168 (Hex)0x84350490 (cpqsvmsg.dll) Log Severity: Warning (2) Event Title: Server Power On Via Manual - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 118
(1) Event Title: Server Blade Inserted Log Message: The server blade has been inserted from the enclosure. SNMP Trap: cpqRackServerBladeInserted - 22029 in CPQRACK.MIB Symptom: Server blade inserted. The server blade has been inserted into the enclosure. User Action: None. Supporting SNMP Trap Data - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 119
Symptom: Power subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName Server agents - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 120
.MIB Symptom: Unknown power consumption. There is an unknown power consumer drawing power. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid Server agents 120 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 121
number of power enclosures has been exceeded. User Action: Remove the extra power enclosure. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqRackName • cpqRackUid • cpqRackCommonEnclosureName • cpqRackCommonEnclosureSerialNum • cpqRackCommonEnclosureTrapSequenceNum Server agents 121 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 122
Power subsystem improperly configured. The power subsystem has been improperly configured. User Action: Check the cabling of the power enclosure. Supporting a firmware update or some other event. User action: None Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Server agents 122 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 123
re-flash the management processor firmware. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags Supporting SNMP Trap Description: The to the server. User Action: None required. Supporting SNMP Trap Data: • sysName, • cpqHoTrapFlags • cpqSeUSBDeviceType • cpqSeUSBDeviceName Supporting SNMP Trap - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 124
can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqsvmsg.dll - 1543 (Hex)0xc4350607 (Service Event) Log Severity: Error (3) Log Message: Unable to load a required driver. This error can be caused by a corrupt or missing - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 125
information. SNMP sets have been disabled. Event identifier: cpqsvmsg.dll - 1803 (Hex)0xc435070b (Service Event) Log Severity: Error (3) registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqsvmsg.dll - 3330 (Hex)0x84350d02 (Service Event) Log Severity - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 126
memory condition. Rebooting the server may correct this error. Event identifier: cpqsvmsg.dll - 3333 (Hex)0x84350d05 (Service Event driver (CPQSM2.SYS) to be installed. Install the driver from the latest Software Support for Windows. If you do not have a Remote Insight Board in this system, disable - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 127
respond to a request. The data contains the error code. Event identifier: cpqsvmsg.dll - 5644 (Hex)0x8435160c (Service Event) Log Severity: Warning (2) Log Message: The Rack And Enclosure MIB Agent received an unknown action code from the service. The data contains the action code. Server agents 127 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 128
)0x84351632 (Service Event) Log Severity: Warning (2) Log Message: The Rack And Enclosure MIB Agent )0x84351633 (Service Event) Log Severity: Warning (2) Log Message: The Rack And Enclosure MIB Agent Hex)0x84351634 (Service Event) Log Severity: Warning (2) Log Message: The Rack And Enclosure MIB Agent - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 129
to read from the registry. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error. Event identifier: cpqnimsg.dll - 262 (Hex)0x84350106 (Service Event) Log Severity: Warning (2) Log Message: Could not create the registry key: "%1". This - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 130
to create thread. This error can be caused by a low memory condition. Rebooting the server may correct this error. Event identifier: cpqnimsg.dll - 271 (Hex)0x8435010f (Service Event) Log Severity: Warning (2) Log Message: Could not open the driver for device "%1". This error can be caused by an - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 131
associated with the team and re-install the drivers and team. Event identifier: cpqnimsg.dll - 274 (Hex)0x84350112 (Service Event) Log Severity: Warning (2) Log Message: The NIC Management Agent cannot generate Traps due to a communication problem with the NIC SNMP extension agent. Event identifier - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 132
Event) Log Severity: Error (3) Log Message: A driver for a NIC failed to open. This error can be caused by an improperly installed adapter. Removing and reinstalling all adapters may correct the problem. The NIC Agent service will not respond to any management requests. Event identifier: cpqnimsg - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 133
is probably not running. Starting WMI service or NIC agent might solve this problem. Event identifier: cpqnimsg.dll - 299 (Hex)0x8435012b (Service Event) Log Severity: Warning (2) Log Message: An attempt to query WMI for Virus Throttle event failed. The event data gives the error number. Event - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 134
by an invalid or missing configuration or by a corrupt registry. Reinstalling the Insight Agents may correct this problem. Event identifier: cpqnimsg.dll - 1033 (Hex)0x44350409 (Service Event) Log Severity: Information (1) Log Message: The SNMP Insight Agent will allow SNMP sets. Event identifier - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 135
Network control panel to verify the Remote Access configuration. If this error persists, reinstalling the Insight Agents or the Remote Access Service may or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP Trap Data: • sysName NIC agents 135 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 136
cable that was unplugged. User Action: None required. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP Trap Data: • sysName NIC agents 136 - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 137
a faulty cable or connecting a cable that was disconnected. User Action: None required. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqNicIfPhysAdapterSlot • cpqNicIfPhysAdapterPort • cpqSiServerSystemId • cpqNicIfPhysAdapterStatus • cpqSePciSlotBoardName • cpqNicIfPhysAdapterPartNumber - HP ProLiant ML330e | Microsoft Windows Event ID and SNMP Traps Reference Guide f - Page 138
to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqNicIfPhysAdapterSlot • cpqNicIfPhysAdapterPort • cpqSiServerSystemId • cpqNicIfPhysAdapterStatus • cpqSePciSlotBoardName
Microsoft Windows Event ID and SNMP Traps
Reference Guide
For use with SmartStart version 8.25
Part number: 347870-009
Ninth edition: June 2009