HP ProLiant SL4540 HP ProLiant SL6000 Scalable System technology
HP ProLiant SL4540 Manual
View all HP ProLiant SL4540 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP ProLiant SL4540 manual content summary:
- HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 1
...3 Mechanical design for extreme scale-out computing 3 HP ProLiant z6000 G6 chassis ...4 Rack and cabling options...4 SL6000 server trays ...5 HP ProLiant SL160z G6 server ...7 HP ProLiant SL170z G6 server ...8 HP ProLiant SL2x170z G6 server 9 Intel Xeon 5500 Series processor technology 10 - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 2
Appendix: PPIC command line utility ...24 For more information...25 Call to action ...25 - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 3
4, 2009, HP ProLiant SL2x170z G6 server garnered the SPECpower_ssj2008 result of 2316 overall ssj_ops/watt∗. Based on industry-standard components, the ProLiant SL6000 Scalable System provides extreme density and high performance at low acquisition costs. SL6000 servers are uniquely serviceable in - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 4
serviceability. In the rear, all power cables are cleanly installed on the right side of the cabinet (Figure 2). For detailed information about rack and cabling options, refer to the HP ProLiant SL6000 Scalable System Cabling Guide at this website: http://bizsupport2.austin.hp.com/bc/docs/support - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 5
. For specific information on supported SAS controllers, SAS hard drive options, and server node storage configuration, refer to the HP technology document "Configuring SATA and SAS in HP ProLiant SL6000 servers" at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01893303/c01893303.pdf - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 6
servicing, video and serial ports, USB ports, NIC ports, and optional out-of-band management LAN ports are located on the front panel of each server view of a ProLiant z6000 G6 chassis fully populated with two HP ProLiant SL170z G6 server trays Figure 4. Front view of a ProLiant z6000 G6 chassis - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 7
or solid state (SSD) SATA storage drives housed in quick-release drive carriers. More detailed information about memory configuration and internal drive support is available in the QuickSpecs at this URL: www.hp.com/servers/SL160z. Figure 5. Internal view of the HP ProLiant SL160z G6 server tray 7 - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 8
HP ProLiant SL170z G6 server The HP ProLiant SL170z G6 server tray is optimized for maximum storage capability (Figure 6). It supports LFF, SFF, or SSD SATA storage drives housed in quick-release drive carriers. The system board accommodates up to two Intel Xeon 5500 Series processors - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 9
the two LFF, SFF, or SSD SATA storage drives housed in quick-release carriers. More detailed information about memory configuration and internal drive support is available in the QuickSpecs at this URL: www.hp.com/servers/SL2x170z. Figure 7. Internal view of the HP ProLiant SL2x170z G6 server tray 9 - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 10
of a ProLiant z6000 G6 chassis populated with 2 HP ProLiant SL2x170z G6 server trays Intel Xeon 5500 Series processor technology HP ProLiant SL6000 Scalable Systems . These small, energy-efficient, high-performance processors support distributed shared memory, Intel Hyper-Threading technology, and - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 11
a three-level cache hierarchy (Figure 9): • An on-core 64-kilobyte Level 1 cache, split into two 32-kilobyte caches: one for data and one for instructions • 256-kilobyte, Level 2 cache for each core to reduce latency • A Level 3 cache of up to 8 megabytes Figure 9. Block diagram of three-level cache - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 12
more instructions to be processed simultaneously. HyperThreading improves performance per watt, allowing Intel-based ProLiant G6 servers to guide for each server tray. Additional information is provided in the "HP ROM-Based Setup Utility User Guide" at http://h20000.www2.hp.com/bc/docs/support - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 13
Power Interface-aware (ACPI) operating systems require no changes to support it. However, it is application dependent and increases processor pins. Because pin damage could require replacing the motherboard, HP engineers developed a special installation tool to simplify processor installation - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 14
a chipset. These processors support only DDR3 dual inline 1333, 1066, and 800 MT/s. Controlled fan speed HP DDR3 DIMM modules have an integrated thermal sensor that signals ProLiant G6 servers can reduce fan speed when memory is idle, which reduces power consumption. The BIOS in ProLiant G6 servers - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 15
not meet stringent design requirements; therefore, HP does not recommend configuring third-party DIMMs for 1333 MT/s data rates with two DIMMs per channel. At this writing, operating the memory at 1333 MT/s is supported only on select ProLiant SL G6 server trays using the Xeon 5500 Series processors - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 16
available on the HP website: www.hp.com/go/ddr3memory-configurator. I/O technologies ProLiant SL G6 server trays incorporate PCIe storage devices such as SATA hard drives. PCI Express technology All ProLiant SL G6 server trays support the PCIe 2.0 specification. PCIe 2.0 has a per-lane signaling - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 17
power supply bay that are used in multiple ProLiant server platforms. Like many other ProLiant G6 servers, the SL6000 Scalable System supports these common power supplies. By reducing the number of power supply designs for ProLiant servers, HP effectively reduces the number of spares customers must - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 18
(Figure 14) provides an example of the high levels of power efficiency achieved by power supplies used in ProLiant G6 servers. Figure 14. Power/Efficiency curve for the 750 W HP power supply Oversized and lightly loaded power supplies do not run as efficiently as those that are heavily loaded - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 19
. If one power supply fails and the remaining power supply cannot support the full load of both server trays, the servers will throttle using HP power capping technology so that the remaining power supply can support both trays (Figure 15). Although performance is reduced, the chassis continues - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 20
management systems detect problems by receiving traps or change notices from network devices implementing SNMP. The ProLiant SL6000 Scalable System uses the same SNMP-based Insight Management Agents supported by other ProLiant servers. As a result, administrators can use HP Systems Insight Manager - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 21
in one of four possible modes as shown in Table 3. Table 3. HP ProLiant G6 chassis power control logic modes Mode Function 0 No Redundancy. Power if the chassis has only one operational power supply. In this mode, the servers are expected to survive an unexpected AC power loss to one of the - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 22
Remote management and control with ProLiant Onboard Administrator All ProLiant SL servers include ProLiant Onboard Administrator powered by LO100i. ProLiant Onboard Administrator provides the core embedded management functions in all ProLiant servers. LO100i works with HP SIM, RBSU, and Option ROM - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 23
serviceability in standard racks. 4 For additional information about the TPM, see the HP technology brief titled "Data security in HP ProLiant servers using the Trusted Platform Module and Microsoft® Windows® BitLocker™ Drive Encryption" at http://h20000.www2.hp.com/bc/docs/support/SupportManual - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 24
line. Running the PPIC utility from the command line without any command-line options will provide the options shown below. HP ProLiant Power Interface Control Utility v.1.09 Copyright (c) 2003, 2009 Hewlett-Packard Development Company, L.P. Usage: POW [Options] options: -d Display and Log - HP ProLiant SL4540 | HP ProLiant SL6000 Scalable System technology - Page 25
Resource description HP ProLiant SL160z G6 Server Software Configuration Guide HP ProLiant SL170z G6 Server Software Configuration Guide HP ProLiant SL2x170z G6 Server Software Configuration Guide HP ProLiant SL6000 Scalable System Cabling Guide HP Power Interface Controller User Guide HP ROM-Based
HP ProLiant SL6000 Scalable System technology
technology brief
Abstract
..............................................................................................................................................
3
Mechanical design for extreme scale-out computing
.................................................................................
3
HP ProLiant z6000 G6 chassis
..........................................................................................................
4
Rack and cabling options
..................................................................................................................
4
SL6000 server trays
.........................................................................................................................
5
HP ProLiant SL160z G6 server
.......................................................................................................
7
HP ProLiant SL170z G6 server
.......................................................................................................
8
HP ProLiant SL2x170z G6 server
...................................................................................................
9
Intel Xeon 5500 Series processor technology
........................................................................................
10
Multi-level caches
...........................................................................................................................
11
QuickPath Interconnect controller
.....................................................................................................
12
Hyper-Threading
............................................................................................................................
12
Turbo Boost technology
...................................................................................................................
13
Processor socket technology
................................................................................................................
13
Memory technologies
.........................................................................................................................
14
DDR3 memory enhancements
..........................................................................................................
14
Controlled fan speed
..................................................................................................................
14
Reduced operating voltage
..........................................................................................................
14
Unbuffered and registered DIMMs
...................................................................................................
15
I/O technologies
...............................................................................................................................
16
PCI Express technology
...................................................................................................................
16
Serial ATA technology
....................................................................................................................
16
Networking technologies
................................................................................................................
17
High Performance Computing technologies
.......................................................................................
17
Power and thermal technologies
..........................................................................................................
17
Power supply options
......................................................................................................................
18
Redundant power operation
............................................................................................................
18
Management and deployment
.............................................................................................................
20
Systems management and monitoring
...............................................................................................
20
Power and thermal management with the Power Management Controller
.............................................
20
Remote management and control with ProLiant Onboard Administrator
................................................
22
IPMI 2.0 and DCMI 1.0
..................................................................................................................
22
Server deployment
.........................................................................................................................
23
Data security technology with the Trusted Platform Module
.....................................................................
23
Summary
..........................................................................................................................................