HP ProSignia 300 Compaq ProSignia 300 Servers Maintenance and Service Guide
HP ProSignia 300 Manual
View all HP ProSignia 300 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP ProSignia 300 manual content summary:
- HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 1
in accordance with the terms of the agreement. Product names mentioned herein may be trademarks and/or registered trademarks of their respective companies. MAINTENANCE AND SERVICE GUIDE COMPAQ PROSIGNIA 300 SERVERS First Edition (December 1994) Text Number 137786-001 - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 2
Preface This Maintenance and Service Guide is a troubleshooting guide that can be used for reference when servicing the Compaq ProSignia 300 Server. Compaq Computer Corporation reserves the right to make changes without notice. Symbols The following text and symbols mark special messages throughout - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 3
, plug the AC power cord into a properly grounded AC outlet only Locating Additional Information The following documentation is available to support these products: o User Documentation o Compaq Service Quick Reference Guide o Service Training Guides o Compaq Service Advisories and Bulletins - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 4
Chapter 1. Illustrated Parts Catalog Chapter 1.0 Introduction This chapter provides the illustrated parts breakdown and a spares parts list for the Compaq ProSignia 300 Server. Chapter 1.1 Exploded View and Spares Parts List - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 5
Table 1-1. Spares Parts List - Compaq ProSignia 300 Ref Description Part Number CHASSIS: -------- 1 Chassis 194491-001 2 J Hood 197836-001 3 Side CD and Diskette Drive rails) 197841-001 8 System Fan with Bracket and Guard 211442-001 9 Board Guide and Speaker Holder 197835-001 - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 6
-001 13 5 1/4 and 3 1/2 Drive Mounting Kit 194493-001 14 Option Slot Cover (Quantity = 5) 141081-001 15 Power Switch and LED Bracket 197832-001 SYSTEM COMPONENTS 16 Power Supply 200W 197416-001 BOARDS: ------17 System Board I/O 184359-001 18 Processor Board for 5/75 MHz Processor (not - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 7
27 2.1 GB Fast-Wide SCSI-2 Drive 28 4.3 GB Fast-Wide SCSI-2 Drive 29 Tray Load CD-ROM Drive (Internal) 30 Tray Load CD-ROM Drive (External) 31 1.44 MB, 3.5" Diskette Drive 32 1.2 MB, 5.25" Diskette Drive 33 2/8 GB DAT Drive with Compression 34 525 MB ACA Tape Drive 35 1.2 GB ACA Tape Drive 36 4/16 - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 8
Keyboard, Belgian 160648-118 * 46 Mouse 141189-201 * Ref Description Part Number MISCELLANEOUS: 47 Battery 160274-001 48 Maintenance and Service Guide 211462-001 * 49 System ROMpaq 143198-001 * 50 Option ROMpaq 142207-001 * 51 Shipping Boxes 211444-001 * 52 Shipping Box - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 9
support software guide for procedures on using the Compaq System Configuration utility when installing or removing expansion boards, mass storage devices, and Extended Industry Standard Architecture (EISA) or Peripheral Component Interconnect (PCI) options. To service the Compaq ProSignia 300 Server - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 10
the AC power cord from the AC outlet, then from the system unit. 3. Disconnect all external peripheral devices from the server. Chapter 2.3 Side Access Panel/Front Bezel WARNING High voltage present. Extreme care must be taken when running the Compaq ProSignia 300 Server without the system - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 11
To remove the Side Access Panel 1. Loosen thumb screws (3) on back bezel. 2. Slide side access panel back and then out. To remove the Front Bezel 1. Remove front bezel retaining screw (1). 2. Push friction tabs up (located underneath bottom edge of bezel) and pull forward. 3. Pull bezel forward at - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 12
the ProSignia 300 Server without the air baffle installed. NOTE: It is not necessary to remove the air baffle to remove any of the server's components except the system I/O board. 1. Press the retaining latch (A) and swing the air baffle out away from the chassis. 2. Place a flat bladed screw driver - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 13
The ProSignia 300 Server has two 3 1/2 drive bays and three 5 1/4 drive bays. - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 14
front bezel. 2. Disconnect power and signal cables from rear of drive. 3. Remove retaining screws (2). 4. Slide mass storage device out. 5. Reverse steps to install replacement. IMPORTANT: When replacing hard drives remove rails before returning the hard drive to Compaq. Replacement rails are not - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 15
- HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 16
Chapter 2.7 Boards This section describes how to remove and replace the processor board, memory modules, option boards, and the system board. Processor Board - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 17
1. Remove retaining screw and pull board straight out. 2. Reverse steps for processor board installation. Memory - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 18
Tilt SIMM module forward (B). 4. Lift SIMM module out (C). 5. To replace SIMM module reverse steps. 6. Run Compaq System Configuration Utility if installed memory size has changed. The Compaq ProSignia 300 Server comes standard with 16 MB of ECC system memory. Memory can be expanded to a maximum of - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 19
standard SIMMs. Non-JEDEC SIMMs may adversely affect data integrity. Table 2-1 shows a sample of typical memory configurations for the Compaq ProSignia 300 Server. Table 2-1. Example of SIMM Upgrade Combinations Processor Board Total Memory * Bank 1 Bank 2 Bank 3 24 MB 2x4 MB 32 - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 20
1. Remove any cables connected to board. 2. Remove retaining screw and pull board straight out. System Board - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 21
1. Remove all expansion boards. 2. Label and disconnect all cables from system board. 3. Remove retaining screws (5). 4. Gently press the I/O panel release tabs and slide the system board forward far enough to clear the retaining stops. WARNING Care should be taken when handling the thin metal - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 22
Add or Replace External Battery 1. Make sure that the power to the system is off. 2. Secure battery to chassis or expose to water or fire. Use only replacement battery/clock modules supplied by Compaq Computer Corporation. Disposal of the battery/clock module should be accomplished within - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 23
return methods Power Supply - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 24
's from bracket. 6. Remove screws at rear and top of power supply (4). 7. Lift power supply out pulling switch and cable through chassis. 8. Reverse order for replacement. NOTE: When replacing power supply, make sure that the power switch cable is properly threaded through the bracket strain relief - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 25
Removing the Microprocessor 1. Open front bezel and remove side access panel. 2. Release and swing the air baffle (not shown) out of the way. WARNING The microprocessor can be HOT. Allow sufficient time for the microprocessor and the processor board to cool before handling 3. Remove the - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 26
1. Align Pin 1 of the microprocessor with Pin 1 of the Zero Insertion Force (ZIF) Socket. 2. Press the microprocessor into the microprocessor socket. 3. Lock the release lever. IMPORTANT: Avoid excessive force when installing the new microprocessor into the ZIF socket. If the microprocessor does not - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 27
Compaq Server products. These include: o Power-On Self-Test (POST) o Diagnostics (DIAGS) o Drive Array Advanced Diagnostics (DAAD) o Automatic Server the Compaq utilities will automatically be available on the system partition. The system partition could also have been created during a manual system - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 28
-On Self-Test (POST) POST is a series of diagnostic tests that run automatically on Compaq computers when the system is turned on. POST checks the following assemblies to ensure that the computer system is functioning properly: o Keyboard o Power supply o System board o Memory o Memory expansion - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 29
follow the instructions in Table 3-1. The error messages and codes listed in Table 3-1 include all codes generated by Compaq products. Problem Action A Critical Error None A catastrophic system Run Diagnostics. occurred prior to error, which caused Replace failed this power-up the server - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 30
the System Configuration/ found. Configuration Slot Mismatch Utility and Device Not Found correct. Error Probable Source Code Beeps of Problem Action 175 - None EISA or PCI board Run the System Configuration/ added, configuration Configuration Slot Mismatch not updated - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 31
Controller Error failure. Error Probable Source Code Beeps of Problem Action 207 - Invalid None Memory module installed Verify Invalid optional cache Replace cache with Error size. 256K cache. (ProSignia VS only) 213 - System 1 Short System processor Install Processor - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 32
, Check with your Controller or mouse controller Authorized Error failure. Compaq Reseller. 304 - Keyboard or None Keyboard, keyboard 1. Make sure , Video display Replace the Adapter Failure 2 Short controller. video board. Error Probable Source Code Beeps of Problem Action - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 33
or spinning. 1612 - Primary 2 Short Primary power supply Replace power power supply has failed supply as soon as failure. possible. 1730 - Fixed Disk None Fixed disk drive error. Run the System 0 does not Configuration support DMA Mode Utility and correct. 1731 - Fixed - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 34
command Utility and correct. Error Probable Source Code Beeps of Problem Action 1751 - Fixed Disk None Fixed disk drive error. None Fixed disk drive error. Run the System 0 does not Configuration support Block Utility and Mode correct. 1761 - Fixed Disk None Fixed disk - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 35
ProSignia VS alert or open side failure or side Drive Subsystem panel. panel open. Error Error Probable Source Code Beeps of Problem as indicated or contact your service provider. Error Probable Source Code Beeps of Problem Action 1782 - Disk Controller Failure - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 36
1785 - Drive None Configuration error. Run the System Array not Configuration Configured Utility and correct. Error Probable Source Code Beeps of Problem Action 1786 - Drive None Interim Data Recovery Press F1 key to Array Recovery mode. Data has not been allow Automatic - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 37
and press F2. -Or- If this message was not due to a bad power cable connection, and no drive replacement took place, this could indicate noise on the Check cable for proper routing. Error Probable Source Code Beeps of Problem Action 1789 - Drive not None Cable or hard drive 1. Check - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 38
Beeps of Problem Action 1793 - Drive None This indicates that Power was not Array - Array while the system was restored within Accelerator in use, power was eight Run the System disabled. Configuration Utility to re-configure the Compaq IDA-2 without the Array Accelerator. - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 39
and to re-enable logical drives. 2 long + 2 short 2 Long Power is cycled. Check fans. beeps 2 Short Temperature too hot. Processor fan occur if the system recognizes a problem while running the Diagnostics program. These error codes help identify possible defective subassemblies. Tables - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 40
an error condition, complete the following steps before starting problem isolation procedures: 1. Ensure that there is proper you must disable the power-on password by using the Password Disable switch on the system board. 6. Install an loopback plug when instructed to by Diagnostics (Part - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 41
109 - xx CMOS clock load data test 1. Replace the battery/clock failed module and re-test. 2. Replace the system board and re-test. 110 - xx Programmable timer load data Replace the system board and test failed re-test for error codes 110 - xx through 113 - xx. 111 - xx Refresh detect - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 42
data register failed 1. Connect the printer. 403 - xx Printer pattern test failed 2. Check the power to the printer. 498 - xx Printer failed or not 3. Install the loopback connected connector and re Replace the system board and re-test. Table 3-6. Video Display Unit Test Error Codes - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 43
502 - xx Video memory test failed 516 - xx: 503 - xx Video attribute test failed 504 - xx Video character set test failed 505 - xx Video 80 x 25 and/or replace the 603 - xx Diskette write/read/compute diskette power and signal test failed cables and re-test. 3. Replace the diskette drive - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 44
apply to 699 - xx error codes: 1. Replace the media. 2. Run the Configuration utility Table 3-8. Monochrome Video Board Test Error Codes Error Description Recommended Action Code 802 - xx Video memory test failed The following steps apply to error codes 802 - xx and 824 - xx - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 45
failed 1. Run the Configuration Utility and verify the drive type. 1702 - xx Fixed disk read test failed 2. Replace the fixed disk drive signal and power cables and 1703 - xx Fixed disk write/read/ re-test. compare test failed 3. Replace the fixed disk drive controller and re-test. 1704 - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 46
- xx Fixed disk ECC * test failed 1719 - xx Fixed disk drive power mode test failed 1736 - xx Drive Monitoring failed 1799 - xx Invalid fixed The following steps apply to error codes 1800 - xx through 1803 - xx CD-ROM Power failed 1823 - xx: 1805 - xx CD-ROM Read failed 1. Replace the CD-ROM - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 47
failed The following steps apply to error codes 2402 - xx through 2403 - xx Video attribute test failed 2456 - xx: 2404 - xx Video character set test failed 2405 - xx Video 80 x 25 mode 9 x 14 character cell test failed 2406 - xx Video 80 x 25 mode 8 x 8 character cell test failed 2407 - xx - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 48
2416 - xx Video noise pattern test failed 2417 - xx Lightpen text mode test failed, no test failed re-test. 3. Replace the Advanced VGA 2431 - xx 640 x 480 graphics test board or other video board failure and re-test. 4. Replace the system board 2432 - xx 320 x 200 graphics and re-test. - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 49
Open failed 6. Replace the controller. * MAU = MultiStation Access Unit ** UTP/STP = Unshielded Twisted Pair/Shielded Twisted Pair. Table 3-16. Server Manager/R Board Test Error Codes Error Description Recommended Action Code 7000 - 11 Processor (80186 Timer) Replace the - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 50
35 HBM Video 7000 - 41 ser_int 7000 - 42 ser_int 7000 - 43 ser_ext 7000 - 44 ser_ext 7000 - 45 ser_ext_int 7000 - 46 ser_ext_int 7000 - 51 mdm_int Replace the Server Manager/R board a DOS-based tool designed to run on all Compaq products that contain a Smart SCSI Array Controller using - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 51
Guide for complete details and procedures about this diagnostic tool. DAAD works by issuing multiple commands to the array controllers to determine if a problem exists. This data can then be saved to a file and, for severe situations, this file can be sent to Compaq not cycle the power because the - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 52
troubleshooting routine. To view the problems detected by DAAD, select the Diagnosis button. If DAAD found no problems, a message, "No Problems installed onto the IDA-2 board. You may need to run the Compaq System Configuration Utility and disable the array accelerator board to get this message - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 53
Possible data loss was detected during power-up due to all of the DAAD does not recognize. Call your Authorized Compaq Reseller for the latest copy of DAAD Accelerator to be taken Accelerator status: Warranty alert A catastrophic problem has occurred with the array accelerator board. Refer to the - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 54
. When DAAD was verifying this interface, a serious problem was detected. A hardware problem has occurred and you should replace the IDA controller firmware is below the latest recommended version. Call your Authorized Compaq Reseller to obtain the latest upgraded firmware Controller firmware needs - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 55
change drive locations, there may be a problem with the placement of the drives. DAAD controller returned an error from its internal Power-On Self Tests. Replace the controller of an operating system device driver. Restart the system. Run command problem such as drive time-out, or was unable - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 56
supports monitor and performance, if desired Drive Monitoring is NOT enabled for drive bay X The monitor and performance features have not been enabled. Run the Compaq in drive position Y. Rearrange the drives according to the DAAD instructions Drive (bay) X RIS copy mismatch The copies of the RIS - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 57
multiple errors, this drive may need to be replaced FYI: Drive (bay) X is non-Compaq supplied The installed drive was not supplied by Compaq. If problems exist with this drive, replace it with a Compaq drive Identify controller data did not match with CMOS The identify controller data from the - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 58
recovery mode and is vulnerable. Replace the failed drive as soon as possible Logical Drive X status = LOOSE CABLE DETECTED A physical drive has a cabling problem. Turn the system off and attempt to reattach the cable onto the drive. If this does not work, replace the cable Logical Drive X status - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 59
loose cable The array controller could not communicate with this drive at power-up. This drive has not previously failed. Check all cable connections , loose, or disconnected. Turn on the system and attempt to reconnect data/power cable to the drive. If this does not work, replace the cable. If - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 60
the array accelerator board Soft Firmware Upgrade required DAAD has determined that your controller is running firmware that has been soft upgraded by the Compaq Upgrade Utility. However, the firmware running is not present on all drives. This could be caused by the addition of new drives in the - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 61
of the problem Wrong Accelerator Services The Compaq ProSignia 300 provides rapid recovery services for diagnosing and recovering from errors. These tools are available for local and remote diagnosis and recovery. The following topics are discussed here: o Automatic Server Recovery (ASR) o Server - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 62
want the Server to recover from critical system faults, and specify when to monitor. This selection process is accomplished through the SmartStart installation process and can be modified through the Compaq System Configuration Utility. The ASR depends on an operating system driver that routinely - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 63
can be done from the Server console. The requirements to use this level of the ASR feature are: o Operating System with ASR support o System Configuration Utility and Diagnostics Utility installed on the system partition of the hard drive o ASR configured to load the Compaq Utilities after reboot - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 64
The standard Compaq ProSignia 300 security password features function differently during Automatic Server Recovery-2 than during a typical system startup. During ASR the system will not prompt for the Power-On Password. This allows the ASR to restart the Operating System or Compaq Utilities without - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 65
resulting in the loading of Compaq Utilities. Error Detected On Boot Up The Server detected an error during the Power-On Self-Test. NMI Compaq ProSignia 300 configuration. The Server has an Automatic Revision Tracking (ART) feature that helps you review recent changes to the Server's - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 66
the previous configuration. This feature allows correlation of hardware changes with Server failure. The following information is stored in the Revision History Table use of flash ROM in the Compaq ProSignia 300 and in certain options controllers allows the firmware (BIOS) to be upgraded with system - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 67
CAUTION Do not turn the power off during a firmware upgrade. A loss of power during upgrade may corrupt the upgrade. - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 68
Chapter 4. Switch and Jumper Information Chapter 4.0 Introduction This chapter provides switch and jumper information for the Compaq ProSignia 300 Server. Chapter 4.1 System Board Compaq ProSignia 300 switch locations on the system board are shown in the figure below. Switch SW1 is a six-position - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 69
ON DISABLED video is disabled if ROM detects an optional video board installed. switch is on (enabled). S5 POWER-ON PASSWORD DEFEAT OFF * DISABLED Password the physical locations of jumpers ID2, ID1, and ID0 on supported SCSI options. Table 4-2. Jumper Settings For SCSI ID Pin 3 - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 70
- HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 71
for the following: o System Unit o Power Supply o SIMMs o Diskette Drives o Fast SCSI-2 Hard Drives o Fast-Wide SCSI-2 Hard Drives o SMART SCSI Array Controller o Integrated 32-Bit Fast-SCSI-2/P Controller o Fast-Wide SCSI-2 Controller o Compaq NetFlex-Controllers Chapter 5.1 System Unit - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 72
Humidity (non condensing): Operating 20% to 80% 20% to 80% Non operating 5% to 90% 5% to 90% Chapter 5.2 Power Supply Specifications Table 5-2. Power Supply Specifications English Metric Input Specifications: Nominal Line Voltage 100 to 120 VAC 220 to 240 VAC Range Input - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 73
pair of SIMMs Maximum Capacity 208 MB * The Compaq ProSignia 300 supports a maximum of 208 MB of system RAM. JEDEC standard SIMMs must be installed in matched pairs and must be 60 or 70 ns. Do not install 80 ns SIMMs in server - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 74
Average (high/low) 169/94 ms 148.3 ms/95ms Settling Time 15 ms 15 ms Latency Average 100 ms 84 ms Cylinders (high/low) 80/80 80/40 Read/Write Heads Two Two Chapter 5.5 535 MB Fast-SCSI-2 Drive Specifications Table 5-5. 535 MB Fast-SCSI-2 Drive Specifications Capacity - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 75
rpm Average Access 9.0 ms 9.0 ms Chapter 5.9 Integrated 32-Bit Fast-SCSI-2/P Controller Table 5-9. Integrated 32-Bit Fast-SCSI-2/P Controller Devices Supported Seven * Data Transfer Method 32-bit bus master SCSI Bus Transfer Rate (maximum) 10 MB/sec Maximum Transfer Rate on PCI - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 76
SCSI Termination Active termination SCSI Connectors 1 external 2 internal (Fast-SCSI-2 and Fast-Wide SCSI-2) Table 5-11. Compaq 32-Bit Fast-Wide SCSI-2 Controller/P Drives Supported Up to seven total (internal and external) Data Transfer Method 32-bit bus master SCSI Channel - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 77
Accelerator 4 MB Mirrored Batteries Yes Battery without Power Yes Charge Trickle Chapter 5.12 NetFlex Controllers Table NetFlex-L ENET Specifications Network Topology Ethernet IEEE 802.3 Compliant Supported Connectors RJ-45 (10Base-T) BNC (10Base2) Processor AMD - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 78
master Max. Transfer Rate on EISA bus 33 MB/s Table 5-16. NetFlex-2 TR Specifications Network Topology Ethernet IEEE 802.5 Compliant Supported Connectors RJ-45 DB-9 Processor TI TMS380C26 Coprocessor TI Packet Blaster (TMS380FPA) Data Transfer Method 32-bit Local Bus master - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 79
2 Coprocessors TI Packet Blaster (TMS380FPA) Data Transfer Method 32-bit EISA bus master Max. Transfer Rate on EISA bus 33 MB/s Chapter 5.13 NetFlex Connector Specifications Table 5-18. DB-9 Pinout Assignments Pin Token Ring Signal Wire Color 1 Receive Data (-) (Red) 2 GND 3 - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 80
8 Not Used 9 CI(-) 10 DO(-) 11 GND 12 DI(-) 13 Fused +12 volts 14 GND 15 Not Used Table 5-21. DB-26 Breakout Connector Pinout Assignments Pin Ethernet Signal Port 1 Port 2 1 CI(-1) 2 GND(1) 3 DO(+1) 4 Not Used 5 CI(-2) 6 Not Used 7 DO(+2) 8 Shield (2) 9 Fused - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 81
20 Shield (1) 21 DI (-1) 22 Not Used 23 CI(+2) 24 Not Used 25 DI(-2) 26 GND (2) NOTE: A(1) after signal name refers to Token Ring STP Port 1 and a (2) after name refers to Token Ring STP Port 2 Table 5-22. RJ-45 Pinout Assignments Pin Ethernet Signal Token Ring Signal - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 82
Distance Up to 50 meters between network controller and the Medium Attachment Unit (MAU) Token cable specifications - Shielded Twisted Pair (STP) Connector type DB-9 Cable type All cable types that meet IEEE 802.5 requirements Token cable specifications - Unshielded Twisted Pair (UTP - HP ProSignia 300 | Compaq ProSignia 300 Servers Maintenance and Service Guide - Page 83
Connector type BNC Cable type RG 58 A/U or RG 58 C/U Distance 185 meters Max length
Notice
The information in this guide is subject to change without notice.
Compaq Computer Corporation shall not be liable for technical or editorial
errors or omissions contained herein; nor for incidental or consequential
damages resulting from the furnishing, performance, or use of this
material.
This guide contains information protected by copyright. No part of this
guide may be photocopied or reproduced in any form without prior written
consent from Compaq Computer Corporation.
Copyright 1994 Compaq Computer Corporation.
All rights reserved. Printed in the U.S.A.
Compaq, Systempro, Deskpro, Compaq Insight Manager,
Registered U.S. Patent and Trademark Office.
ProSignia, Systempro/XL, ProLiant, NetFlex, ROMPaq, and QVision are
trademarks of Compaq Computer Corporation.
The software described in this guide is furnished under a license agreement
or nondisclosure agreement. The software may be used or copied only in
accordance with the terms of the agreement.
Product names mentioned herein may be trademarks and/or registered
trademarks of their respective companies.
MAINTENANCE AND SERVICE GUIDE
COMPAQ PROSIGNIA 300 SERVERS
First Edition (December 1994)
Text Number 137786-001