HP SB40c StorageWorks SB40c Storage Blade User Guide

HP SB40c Manual

HP SB40c manual content summary:

  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 1
    HP StorageWorks SB40c Storage Blade User Guide September 2006 (First Edition) Part Number 433904-001
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 2
    of Linus Torvalds. September 2006 (First Edition) Part Number 433904-001 Audience assumptions This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 3
    a full-height partner server blade 11 Installing a storage blade ...12 Hardware options installation...15 Hard drive options ...15 SAS and SATA hard drive guidelines 15 SAS or SATA hard drive...15 HP Smart Array P400 Controller...16 Configuration and utilities ...17 Configuration tools ...17 Array
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 4
    28 Grounding methods to prevent electrostatic discharge 28 Specifications ...29 Environmental specifications ...29 Storage blade specifications ...29 Technical support...30 Before you contact HP...30 HP contact information ...30 Customer Self Repair ...30 Acronyms and abbreviations...38 Index...40
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 5
    In this section Front panel LEDs ...5 Front panel components ...6 SAS and SATA device numbers ...6 SAS and SATA hard drive LEDs ...7 SAS and SATA hard drive LED combinations 7 Front panel LEDs Item Description Status 1 UID LED Blue = Identified Off = Not identified 2 System health LED
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 6
    Front panel components Item Description 1 Serial pull tab 2 Storage blade handle SAS and SATA device numbers Component identification 6
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 7
    failure alert has been received for this drive. Replace the drive as soon as possible. The drive is online, but it is not active currently. Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is part of an array that is undergoing capacity
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 8
    has placed it offline. Replace the drive as soon as possible. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is offline, a spare, or not configured as part of an array. For more information, see "HP Smart Array P400 Controller (on page
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 9
    SB40c so the partner server blade can identify and configure them at power up. • Be sure that the SB40c is installed as shown in the installation guidelines (on page 11). • Be sure that the partner server blade is powered down. To power up the SB40c: 1. Install the SB40c ("Installing a storage blade
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 10
    When unpacking the HP StorageWorks SB40c storage blade, locate the following items: • HP StorageWorks SB40c storage blade • Coupler plate • Documentation kit Installing an HP BladeSystem c-Class enclosure Before performing any procedures specific to the SB40c, install an HP BladeSystem c-Class
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 11
    An SB40c supports one partner server blade, and a partner server blade supports one SB40c. • Install hard drives in the SB40c before installing the SB40c in the enclosure. • Be sure that the partner server blade is powered down before installing the SB40c. Onboard Administrator is used to configure
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 12
    server blade, a half-height server blade can be installed in the empty bay above the SB40c. This server blade cannot be partnered with the SB40c. Installing a storage blade CAUTION: To prevent improper cooling and thermal damage, do not operate the server blade or the enclosure unless all hard drive
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 13
    • To install the SB40c with a full-height server blade, install the coupler plate. 5. Prepare the storage blade for installation. 6. Install the storage blade: Setup 13
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 14
    • Partnered with a half-height server blade • Partnered with a full-height server blade 7. Install a server blade. See the documentation that ships with the server blade. 8. Configure the SB40c ("Configuration tools" on page 17). Setup 14
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 15
    to the SB40c, observe the following general guidelines: • Install hard drives in in the lowest-numbered available hard drive bay. • To provide the greatest storage space efficiency when drives are grouped together in the same drive array, drives must be the same capacity . NOTE: ACU does not support
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 16
    enclosure ("Installing a storage blade" on page 12). 5. Power up the partner server blade. See the server blade documentation. 6. Determine the status of the hard drive from the SAS and SATA hard drive LED combinations (on page 7). 7. Configure the SB40c ("Configuration tools" on page 17). HP Smart
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 17
    CD or the HP website (http://www.hp.com). Option ROM Configuration for Arrays Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign RAID levels, and establish online spare configurations. The utility also provides support for the following
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 18
    to enable fault, performance, and configuration management. The agents allow easy manageability of the server through HP SIM software, and thirdparty SNMP management platforms. Management Agents are installed with every SmartStart assisted installation or can be installed through the HP PSP. The
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 19
    Pack Services offer upgraded service levels to extend and expand standard product warranty with easy-to-buy, easy-to-use support packages that help you make the most of your server investments. Refer to the Care Pack website (http://www.hp.com/hps/carepack/servers/cp_proliant.html). Configuration
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 20
    22 Automatic data recovery (rebuild) ...23 Drive failure in a NetWare environment...24 When the storage blade does not power up If the SB40c does not start: 1. Be sure that the SB40c is installed adjacent to the partner server blade. 2. Use the Onboard Administrator to be sure that sufficient
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 21
    the Management CD.) • ADU lists all failed drives. • CPQONLIN identifies failed drives in a NetWare environment. For additional information about diagnosing hard drive problems, see the HP ProLiant Servers Troubleshooting Guide. CAUTION: Sometimes, a drive that has previously failed may seem to be
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 22
    rebuilt. If the array has no online spare, any logical drives in this array that are configured with RAID 5 fault tolerance will fail. Compromised fault tolerance can also be caused by non-drive problems, such as a faulty cable or temporary power loss to a storage system. In such cases, you do not
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 23
    spare drive • Failure of a drive that is not mirrored to any other failed drives (in a RAID 1+0 configuration) • Failure of a second drive in a RAID 6 configuration a conservative estimate, and newer drive models usually require less time to rebuild. System performance is affected during the rebuild,
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 24
    the drive each flash once in an alternating pattern to indicate a successful connection. The online LED flashes, indicating that the SB40c recognized the drive replacement and began the recovery process. 4. If applicable, power up the partner server blade ("Power up" on page 9). Troubleshooting 24
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 25
    the data is still valid and accessible during the rebuilding process. However, the driver knows that a physical drive has failed. A message is printed on the console notifying the user that a physical drive is in a degraded state. CPQONLIN also shows that the drive has failed. Troubleshooting 25
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 26
    notices In this section Regulatory compliance identification numbers 26 European Union regulatory notice ...26 Disposal of waste equipment by users in private households in the European Union 27 Regulatory compliance identification numbers For the purpose of regulatory compliance certifications
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 27
    Disposal of waste equipment by users in private households in the European Union This symbol on the product or on waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Regulatory compliance notices 27
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 28
    floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 29
    corresponds to a pressure minimum of 70 KPa. ‡ Maximum allowable altitude change rate is 457 m/min (1500 ft/min) Storage blade specifications Specification Height Depth Width Weight (maximum) Weight (no drives installed) Value 5.56 cm (2.19 in) 50.95 cm (20.06 in) 18.16 cm (7.15 in) 5.0 kg (11
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 30
    time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 31
    HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 32
    ricambio da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No" bzw. „Nein" gekennzeichnet. Technical support
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 33
    gbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendrá
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 34
    HP (of een HP Service Partner Service Partner voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.nl/services HP (ou fornecedores/parceiros de serviço da HP desejar que a HP substitua essas pe que a HP as substitua
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 35
    técnico da HP para que um técnico o ajude por telefone. A HP especifica nos materiais HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP HP poderá cobrar a reposição. Para as peças de reparo feito pelo cliente, a HP feito pelo cliente da HP, entre em contato com o fornecedor
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 36
    Technical support 36
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 37
    Technical support 37
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 38
    Utility CSR Customer Self Repair FC Fibre Channel ISEE Instant Support Enterprise Edition ORCA Option ROM Configuration for Arrays OSEM Open Services Event Manager PSP ProLiant Support Pack RAID redundant array of inexpensive (or independent) disks SAS serial attached SCSI SATA serial ATA
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 39
    SIM Systems Insight Manager UID unit identification Acronyms and abbreviations 39
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 40
    of 21 hard drives 15 hard drives, installing 15 hardware options 15 hardware options installation 15 health LEDs 5 HP ProLiant Essentials Foundation Pack 18 HP Systems Insight Manager, overview 18 HP Technical Support 30 I identification number 26 installation instructions 12 L LED, internal
  • HP SB40c | StorageWorks SB40c Storage Blade User Guide - Page 41
    specifications 29 static electricity 28 support 18, 30 T technical support 30 telephone numbers 30 troubleshooting 20 U UID LEDs 5 Index 41
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

HP StorageWorks SB40c Storage Blade
User Guide
September 2006 (First Edition)
Part Number 433904-001