HP Server rp7420 Read Me First: HP AB322A 4 GB DIMM Installation Guide
HP Server rp7420 Manual
View all HP Server rp7420 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Server rp7420 manual content summary:
- HP Server rp7420 | Read Me First: HP AB322A 4 GB DIMM Installation Guide - Page 1
2003 currently do not support 4 GB DIMMs. Minimum Operating System Versions rp7420/rp8420: HP-UX 11.11 HWE 0406 rx7620/rx8620: HP-UX 11.23 HWE 0403 Linux Rhel 3 update 2 Firmware Requirements Before installing 4 GB DIMMs on hp 9000 rp7420 and hp 9000 rp8420 servers, the server must be updated to - HP Server rp7420 | Read Me First: HP AB322A 4 GB DIMM Installation Guide - Page 2
download bundle and includes the upgrade instructions. To download the Firmware Update Release Notice and firmware patch, go to one of the applicable web sites listed. For rp7420/rp8420: Internal web site ftp://hpatlse.atl.hp.com/firmware_patches/hp/cpu Download PF_CRAIMED0200.tar.gz External web - HP Server rp7420 | Read Me First: HP AB322A 4 GB DIMM Installation Guide - Page 3
HP AB322A 4 GB DIMM Installation Guide NOTE Failure to upgrade firmware might result in error messages the PE command in the MP menu. 16. Replace the right side cover. 17. Power on the server and check that all memory is present. For example: For PA-RISC servers boot to the BCH prompt and issue
HP AB322A 4 GB DIMM Installation Guide
Part No.: AB322-96001
1
HP AB322A 4 GB DIMM Installation Guide
IMPORTANT
Configuration restrictions apply.
4 GB DIMMs cannot be mixed with any other sized DIMMs on the same cell board.
However, 4 GB DIMMs can be mixed with other sized DIMMs within the same
nPartition as long as they are not mixed on the same cell board.
NOTE
hp Integrity rx7620/rx8620 servers running Microsoft Window Server 2003 currently
do not support 4 GB DIMMs.
Minimum Operating System Versions
rp7420/rp8420:
HP-UX 11.11 HWE 0406
rx7620/rx8620:
HP-UX 11.23 HWE 0403
Linux Rhel 3 update 2
Firmware Requirements
Before installing 4 GB DIMMs on hp 9000 rp7420 and hp 9000 rp8420 servers, the server must be updated to
rp7420/rp8420 firmware version 2.0 or higher. To verify that version 2.0 is installed, run the MP
sysrev
command and verify firmware and programmable hardware versions using Table 1.
For hp Integrity rx7620 and hp Integrity rx8620 servers, the server must be updated to rx7620/rx8620
firmware version 2.0 or higher. To verify that version 2.0 is installed, run the MP
sysrev
command and
verify the firmware and programmable hardware versions using Table 1.
READ ME FIRST