HP StorageWorks 2/128 Brocade Fabric OS Message Reference Guide (53-1000242-01
HP StorageWorks 2/128 - SAN Director Switch Manual
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/128 manual content summary:
- HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 1
Fabric OS Message Reference Supporting Fabric OS v5.2.0 Publication Number: 53-1000242-01 Publication Date: 09/29/06 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 2
http://www.brocade.com/support/oscd. Export of technical data contained in this document may require an export license from the United States Government. Brocade Communications Systems, Incorporated Corporate Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Jose, CA - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 3
Brocade Manual Fabric OS System Error Message Reference Manual Fabric OS System Error Message Reference Manual Fabric OS System Error Message Reference Manual Fabric OS System Error Message Reference Manual and hardware support March 2004 53 PLAT-1001 Added BM, FCR, IPS, FCIP, SEC, and ZONE messages - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 4
- HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 5
Contents About This Document How This Document Is Organized Supported Hardware and Software What's New in This Document Document Conventions Additional Information Getting Technical Help Document Feedback xlvii xlvii xlviii xlix l liii liv Chapter 1 Introduction - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 6
Responding to a System Message 1-12 Looking Up a System Message 1-12 Gathering Information About the Problem 1-13 Support 1-13 Panic Dump and Core Dump Files 1-14 Trace Dumps 1-14 supportSave Command 1-14 System Module Descriptions 1-15 Section I RASLog Messages Chapter 2 AUTH System - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 7
Chapter 3 AUTH-1028 2-8 AUTH-1029 2-9 AUTH-1030 2-9 AUTH-1031 2-10 AUTH-1032 2-10 AUTH-1033 2-11 AUTH-1034 2-11 AUTH-1035 2-11 AUTH-1036 2-12 AUTH-1037 2-12 AUTH-1038 2-13 BL System Messages BL-1000 2-1 BL-1001 2-1 BL-1002 2-1 BL-1003 2-2 BL-1004 2-2 BL-1006 2-3 BL-1007 2-3 BL- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 8
Chapter 4 Chapter 5 BL-1020 2-8 BL-1021 2-9 BL-1022 2-9 BL-1023 2-9 BL-1024 2-10 BL-1025 2-10 BL-1026 2-10 BL-1027 2-11 BL-1028 2-11 BL-1029 2-11 BL-1030 2-12 BL-1031 2-12 BL-1032 2-12 BL-1033 2-13 BL-1034 2-13 BL-1035 2-14 BLL System Messages BLL-1000 2-1 BM System Messages BM- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 9
Chapter 6 Chapter 7 Chapter 8 Chapter 9 BM-1056 2-5 BM-1058 2-5 CDR System Messages CDR-1001 2-1 CDR-1002 2-1 CER System Messages CER-1001 2-1 CONF System Messages CONF-1000 2-1 CONF-1001 2-1 CONF-1020 2-2 CONF-1021 2-2 CONF-1022 2-2 EM System Messages EM-1001 2-1 EM-1002 2-1 EM-1003 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 10
-1047 2-13 EM-1048 2-13 EM-1049 2-14 EM-1050 2-14 EM-1051 2-14 EM-1055 2-15 EM-1056 2-15 EM-1057 2-15 EM-1058 2-16 EM-1059 2-16 EM-1060 2-16 EM-1061 2-17 x Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 11
EM-1062 2-17 EM-1063 2-17 EM-2003 2-18 Chapter 10 EVMD System Messages EVMD-1001 2-1 Chapter 11 FABR System Messages FABR-1001 2-1 FABR-1002 2-1 FABR-1003 2-2 FABR-1004 2-2 FABR-1005 2-3 FABR-1006 2-3 FABR-1007 2-3 FABR-1008 2-4 FABR-1009 2-4 FABR-1010 2-4 FABR-1011 2-5 FABR-1012 2-5 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 12
-1014 2-5 FABS-1015 2-5 Chapter 13 FBC System Messages FBC-1001 2-1 Chapter 14 FCIP System Messages FCIP-1000 2-1 Chapter 15 FCMC System Messages FCMC-1001 2-1 Chapter 16 FCPD System Messages FCPD-1001 2-1 FCPD-1002 2-1 xii Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 13
FCPD-1003 2-2 Chapter 17 FCPH System Messages FCPH-1001 2-1 Chapter 18 FCR System Messages FCR-1001 2-1 FCR-1002 2-1 FCR-1003 2-1 FCR-1004 2-2 FCR-1005 2-2 FCR-1006 2-2 FCR-1007 2-3 FCR-1008 2-3 FCR-1009 2-3 FCR-1010 2-4 FCR-1011 2-4 FCR-1012 2-4 FCR-1013 2-5 FCR-1015 2-5 FCR-1016 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 14
FCR-1040 2-13 FCR-1041 2-14 FCR-1042 2-14 FCR-1043 2-14 FCR-1048 2-15 FCR-1049 2-15 FCR-1053 2-15 FCR-1054 2-16 FCR-1055 2-16 FCR-1056 2-16 FCR-1057 2-17 FCR-1058 2-17 FCR-1059 2-17 FCR-1060 2-18 FCR-1061 2-18 FCR-1062 2-19 FCR-1063 2-19 FCR-1064 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 15
FCR-1067 2-20 FCR-1068 2-21 FCR-1069 2-21 FCR-1070 2-21 FCR-1071 2-22 FCR-1072 2-22 FCR-1073 2-22 Chapter 19 FICU System Messages FICU-1001 2-1 FICU-1002 2-1 FICU-1003 2-2 FICU-1004 2-2 FICU-1005 2-3 FICU-1006 2-3 FICU-1007 2-3 FICU-1008 2-4 FICU-1009 2-4 FICU-1010 2-4 Chapter 20 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 16
FSPF-1002 2-1 FSPF-1003 2-1 FSPF-1005 2-2 FSPF-1006 2-2 Chapter 23 FSS System Messages FSS-1001 2-1 FSS-1002 2-1 FSS-1003 2-2 FSS-1004 2-2 FSS-1005 2-2 FSS-1006 2-3 FSS-1007 2-3 Chapter 24 FSSM System Messages FSSM-1002 2-1 FSSM-1003 2-1 FSSM-1004 2-2 Chapter 25 FW System Messages FW- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 17
-1114 2-12 FW-1115 2-13 FW-1116 2-13 FW-1117 2-13 FW-1118 2-14 FW-1119 2-14 FW-1120 2-15 FW-1121 2-15 FW-1122 2-16 FW-1123 2-16 Fabric OS Message Reference xvii Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 18
FW-1124 2-16 FW-1125 2-17 FW-1126 2-17 FW-1127 2-18 FW-1128 2-18 FW-1129 2-19 FW-1130 2-19 FW-1131 2-19 FW-1132 2-20 FW- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 19
FW-1178 2-29 FW-1179 2-30 FW-1180 2-30 FW-1181 2-30 FW-1182 2-31 FW-1183 2-31 FW-1184 2-31 FW-1185 2-32 FW-1186 2-32 FW-1187 2-32 FW-1188 2-33 FW-1189 2-33 FW-1190 2-33 FW-1191 2-34 FW-1192 2-34 FW-1193 2-34 FW-1194 2-35 FW-1195 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 20
2-45 FW-1301 2-45 FW-1302 2-45 FW-1303 2-46 FW-1304 2-46 FW-1305 2-47 FW-1306 2-47 FW-1307 2-47 FW-1308 2-48 FW-1309 2-48 FW-1310 2-49 FW-1311 2-49 FW-1312 2-49 FW-1313 2-50 FW-1314 2-50 FW-1315 2-50 xx Fabric OS Message Reference Publication - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 21
FW-1316 2-51 FW-1317 2-51 FW-1318 2-51 FW-1319 2-52 FW-1320 2-52 FW-1321 2-53 FW-1322 2-53 FW-1323 2-53 FW-1324 2-54 FW-1325 2-54 FW-1326 2-54 FW-1327 2-55 FW-1328 2-55 FW-1329 2-56 FW-1330 2-56 FW-1331 2-56 FW-1332 2-57 FW-1333 2-57 FW-1334 2-57 FW-1335 2-58 FW-1336 2-58 FW- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 22
FW-1347 2-63 FW-1348 2-63 FW-1349 2-63 FW-1350 2-64 FW-1351 2-64 FW-1352 2-65 FW-1353 2-65 FW-1354 2-66 FW-1355 2-66 FW-1356 2-66 FW-1357 2-67 FW-1358 2-67 FW-1359 2-68 FW- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 23
FW-1378 2-75 FW-1379 2-75 FW-1400 2-75 FW-1401 2-76 FW-1402 2-76 FW-1403 2-76 FW-1424 2-77 FW-1425 2-77 FW-1426 2-77 FW-1427 2-78 FW-1428 2-78 FW-1429 2-78 FW-1430 2-79 FW-1431 2-79 FW-1432 2-79 FW-1433 2-80 FW-1434 2-80 FW-1435 2-81 FW-1436 2-81 FW-1437 2-81 FW-1438 2-82 FW- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 24
Chapter 26 HAM System Messages HAM-1001 2-1 HAM-1002 2-1 HAM-1004 2-2 Chapter 27 HAMK System Messages HAMK-1001 2-1 HAMK-1002 2-1 HAMK-1003 2-2 HAMK-1004 2-2 Chapter 28 HIL System Messages HIL-1101 2-1 HIL-1102 2-1 HIL-1103 2-2 HIL-1104 2-2 HIL-1105 2-2 HIL-1106 2-3 HIL-1107 2-3 HIL- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 25
HIL-1503 2-13 HIL-1504 2-13 HIL-1505 2-14 HIL-1506 2-14 HIL-1507 2-14 HIL-1508 2-15 HIL-1509 2-15 HIL-1510 2-16 HIL-1601 2-16 HIL-1602 2-16 Chapter 29 HLO System Messages HLO-1001 2-1 HLO-1002 2-1 HLO-1003 2-2 Chapter 30 HMON System Messages HMON-1001 2-1 Fabric OS Message Reference - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 26
32 IBPD System Messages IBPD-1001 2-1 IBPD-1002 2-1 IBPD-1003 2-2 Chapter 33 ICPD System Messages ICPD-1001 2-1 ICPD-1002 2-1 ICPD-1003 2-1 ICPD-1004 2-2 ICPD-1005 2-2 ICPD-1006 2-2 ICPD-1007 2-3 ICPD-1008 2-3 Chapter 34 IPS System Messages IPS-1001 2-1 IPS-1002 2-1 IPS-1003 2-1 IPS - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 27
Chapter 36 ISNS System Messages ISNS-1001 2-1 ISNS-1002 2-1 ISNS-1003 2-2 ISNS-1004 2-2 ISNS-1005 2-2 ISNS-1006 2-3 ISNS-1008 2-3 ISNS-1009 2-3 ISNS-1010 2-4 ISNS-1011 2-4 ISNS-1013 2-4 Chapter 37 KSWD System Messages KSWD-1003 2-1 Chapter 38 KTRC System Messages KTRC-1001 2-1 KTRC-1002 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 28
LSDB-1004 2-2 Chapter 41 MFIC System Messages MFIC-1001 2-1 MFIC-1002 2-1 MFIC-1003 2-2 Chapter 42 MPTH System Messages MPTH-1001 2-1 MPTH-1002 2-1 MPTH-1003 2-1 Chapter 43 MQ System Messages MQ-1004 2-1 Chapter 44 MS System Messages MS-1001 2-1 MS-1002 2-1 MS-1003 2-2 MS-1004 2-2 MS- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 29
-1009 2-3 PDM-1010 2-4 PDM-1011 2-4 PDM-1012 2-4 PDM-1013 2-5 PDM-1014 2-5 PDM-1017 2-5 PDM-1019 2-6 PDM-1020 2-6 PDM-1021 2-6 Chapter 48 PDTR System Messages PDTR-1001 2-1 PDTR-1002 2-1 Chapter 49 PLAT System Messages PLAT-1000 2-1 Fabric OS Message Reference xxix Publication Number - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 30
PLAT-1001 2-1 Chapter 50 PORT System Messages PORT-1003 2-1 PORT-1004 2-1 PORT-1005 2-2 Chapter 51 PS System Messages PS-1000 2-1 PS-1001 2-1 PS-1002 2-1 PS-1003 2-2 PS-1004 2-2 PS-1005 2-2 Chapter 52 PSWP System Messages PSWP-1001 2-1 PSWP-1002 2-1 PSWP-1003 2-2 Chapter 53 RAS System - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 31
RCS-1005 2-2 RCS-1006 2-3 RCS-1007 2-3 RCS-1008 2-4 Chapter 55 RPCD System Messages RPCD-1001 2-1 RPCD-1002 2-1 RPCD-1003 2-1 RPCD-1004 2-2 RPCD-1005 2-2 RPCD-1006 2-2 RPCD-1007 2-3 Chapter 56 RTWR System Messages RTWR-1001 2-1 RTWR-1002 2-1 RTWR-1003 2-2 Chapter 57 SCN System Messages - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 32
SEC-1022 3-4 SEC-1024 3-4 SEC-1025 3-5 SEC-1026 3-5 SEC-1028 3-5 SEC-1029 3-6 SEC-1030 3-6 SEC-1031 3-6 SEC-1032 3-7 SEC-1033 3-7 SEC-1034 3-8 SEC-1035 3-8 SEC-1036 3-8 SEC-1037 3-9 SEC-1038 3-9 SEC-1040 3-9 SEC-1041 3-10 SEC-1042 3-10 SEC-1043 3-10 SEC-1044 3-11 SEC-1045 3-11 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 33
SEC-1059 3-15 SEC-1062 3-15 SEC-1063 3-15 SEC-1064 3-16 SEC-1065 3-16 SEC-1069 3-16 SEC-1071 3-17 SEC-1072 3-17 SEC-1073 3-17 SEC-1074 3-18 SEC-1075 3-18 SEC-1076 3-18 SEC-1077 3-19 SEC-1078 3-19 SEC- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 34
SEC-1111 3-29 SEC-1112 3-30 SEC-1115 3-30 SEC-1116 3-30 SEC-1117 3-31 SEC-1118 3-31 SEC-1119 3-31 SEC-1121 3-32 SEC-1122 3-32 SEC-1123 3-32 SEC-1124 3-33 SEC-1126 3-33 SEC-1130 3-33 SEC-1135 3-34 SEC-1136 3-34 SEC-1137 3-34 SEC-1138 3-35 SEC-1139 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 35
SEC-1142 3-35 SEC-1145 3-36 SEC-1146 3-36 SEC-1153 3-37 SEC-1154 3-37 SEC-1155 3-37 SEC-1156 3-38 SEC-1157 3-38 SEC-1158 3-38 SEC-1159 3-39 SEC-1160 3-39 SEC-1163 3-39 SEC-1164 3-40 SEC-1165 3-40 SEC-1166 3-40 SEC-1167 3-41 SEC-1168 3-41 SEC-1170 3-41 SEC-1171 3-42 SEC-1172 3-42 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 36
SEC-1187 3-46 SEC-1188 3-46 SEC-1189 3-47 SEC-1190 3-47 SEC-1191 3-47 SEC-1192 3-48 SEC-1193 3-48 SEC-1194 3-48 SEC-1195 3-49 SEC-1196 3-49 SEC-1197 3-49 SEC-1198 3-50 SEC-1199 3-50 SEC-1200 3-50 SEC-1201 3-51 SEC-1202 3-51 SEC- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 37
SEC-1311 3-57 SEC-1312 3-57 SEC-1313 3-57 SEC-1314 3-58 SEC-1315 3-58 SEC-1316 3-58 SEC-1317 3-59 SEC-1318 3-59 SEC-1319 3-59 SEC-1320 3-60 SEC-1321 3-60 SEC-1322 3-60 SEC-1323 3-61 SEC-1324 3-61 SEC-1325 3-61 SEC-1326 3-62 SEC-1327 3-62 Chapter 59 SNMP System Messages SNMP-1001 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 38
SWCH-1006 3-3 SWCH-1007 3-3 SWCH-1008 3-3 Chapter 63 SYSC System Messages SYSC-1001 3-1 SYSC-1002 3-1 SYSC-1003 3-2 SYSC-1004 3-2 SYSC-1005 3-2 Chapter 64 SYSM System Messages SYSM-1001 3-1 SYSM-1002 3-1 SYSM-1003 3-2 xxxviii Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 39
SYSM-1004 3-2 SYSM-1005 3-2 SYSM-1006 3-3 SYSM-1007 3-3 Chapter 65 TRCE System Messages TRCE-1001 3-1 TRCE-1002 3-1 TRCE-1003 3-2 TRCE-1004 3-2 TRCE-1005 3-2 TRCE-1006 3-3 TRCE-1007 3-3 TRCE-1008 3-3 TRCE-1009 3-4 TRCE-1010 3-4 TRCE-1011 3-4 TRCE-1012 3-5 Chapter 66 TRCK System - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 40
Chapter 68 UCST System Messages UCST-1003 3-1 UCST-1007 3-1 UCST-1020 3-2 Chapter 69 UPTH System Messages UPTH-1001 3-1 Chapter 70 USWD System Messages USWD-1006 3-1 Chapter 71 WEBD System Messages WEBD-1001 3-1 WEBD-1002 3-1 WEBD-1003 3-1 WEBD-1004 3-2 WEBD-1005 3-2 WEBD-1006 3-2 WEBD- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 41
ZONE-1010 3-4 ZONE-1012 3-4 ZONE-1013 3-4 ZONE-1014 3-5 ZONE-1015 3-5 ZONE-1017 3-5 ZONE-1018 3-6 ZONE-1019 3-6 ZONE-1022 3-7 ZONE-1023 3-7 ZONE-1024 3-7 ZONE-1026 3-8 ZONE-1027 3-8 ZONE-1028 3-8 ZONE-1029 3-9 ZONE-1030 3-9 ZONE-1031 3-10 ZONE-1032 3-10 ZONE-1033 3-10 ZONE-1034 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 42
ZONE-1046 3-15 Section II Audit Log Messages Chapter 74 AUDIT AUTH System Messages AUTH-3001 74-1 AUTH-3002 74-1 AUTH-3003 74-2 Chapter 75 AUDIT CONF System Messages CONF-1000 3-1 CONF-1020 3-1 CONF-1022 3-2 Chapter 76 AUDIT HTTP System Messages HTTP-1002 3-1 HTTP-1003 3-1 Chapter 77 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 43
SEC-3014 3-6 SEC-3015 3-6 SEC-3016 3-6 SEC-3017 3-7 SEC-3018 3-7 SEC-3019 3-8 SEC-3020 3-8 SEC-3021 3-8 SEC-3022 3-9 SEC-3023 3-9 SEC-3024 3-9 SEC-3025 3-10 SEC-3026 3-10 SEC-3027 3-10 SEC-3028 3-11 SEC-3029 3-11 SEC-3030 3-11 SEC-3031 3-12 SEC-3032 3-12 SEC-3033 3-12 SEC-3034 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 44
SULB-1017 3-9 SULB-1018 3-10 SULB-1020 3-10 SULB-1021 3-11 SULB-1023 3-11 SULB-1024 3-11 SULB-1026 3-12 SULB-1030 3-12 SULB-1034 3-12 Chapter 80 AUDIT ZONE System Messages ZONE-3001 3-1 ZONE-3002 3-1 ZONE-3003 3-2 ZONE-3004 3-2 ZONE-3005 3-2 ZONE-3006 3-3 ZONE-3007 3-3 ZONE-3008 3-3 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 45
ZONE-3022 3-8 ZONE-3023 3-9 ZONE-3024 3-9 ZONE-3025 3-9 Fabric OS Message Reference xlv Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 46
xlvi Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 47
This document is a command reference manual written to help system administrators and technicians operate, maintain, and troubleshoot SAN products. "About This Document" contains the following sections: • "How This Document Is Organized," next • "Supported Hardware and Software" on page xlvii - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 48
switch • Brocade SilkWorm 24000 director • Brocade SilkWorm 48000 director In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported are new: - Chapter 32, "IBPD System Messages" - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 49
narrative portions of this guide are presented in mixed lettercase is often all lowercase. Otherwise, this manual specifically notes those cases in which you to potential damage to hardware, firmware, software, or data. Warning A warning Key Terms For definitions of SAN-specific terms, visit the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 50
48000 Hardware Reference Manual • SilkWorm 48000 QuickStart Guide • FR4-18i Hardware Reference Manual • FR4-16IP Hardware Reference Manual SilkWorm 24000 • SilkWorm 24000 Hardware Reference Manual • SilkWorm 24000 QuickStart Guide SilkWorm 24000/48000 • Port Blade and Filler Panel Replacement - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 51
• SilkWorm 3250/3850 Hardware Reference Manual • SilkWorm 3250/3850 QuickStart Guide SilkWorm 200E SilkWorm 200E Hardware Reference Manual For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through: http://www.amazon - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 52
frames, encapsulating the result in IP packets on entering the tunnel, and then reconstructing them as they leave the tunnel. Fabric OS supports eight FCIP interswitch links between two SilkWorm switches (SilkWorm 7500 or SilkWorm 48000 with a FR4-18i blade) or routes. All 16 links can be used as - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 53
Support contract number, if applicable • Switch model • Switch operating system version • Error numbers and messages received • supportSave command output • Detailed description of the problem and specific questions • Description of any troubleshooting switches and SilkWorm 24000, and 48000 directors - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 54
find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to: [email protected] Provide the title and version number and as much detail as possible about your issue, including the topic heading and page number and your - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 55
1 This guide supports Fabric OS v5.2.0 and documents system messages that you can use to diagnose and fix problems with the switch or fabric. following: • The system message log saves all messages to nonvolatile storage by default. • The system message log can save a maximum of 1024 messages in - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 56
command. The sequence number is persistent across power cycles and switch reboots. • By default, the errDump and errShow commands display all of using the auditCfg command (the classes include zone, security, configuration, firmware, and fabric). The defined set of Audit messages are sent to - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 57
. When the log is full, the newest log entries overwrite the oldest log entries. Port logs capture switch-todevice, device-to-switch, switch-to-switch, some device A-to-device B, and control information. Port logs are not persistent and are lost over power cycles and reboots. Run the portLogShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 58
Logs Command Description agtCfgDefault Resets the SNMP recipients to default values. agtCfgSet Modifies the SNMP agent configuration. filter configuration. errClear Clears all error log messages for all switch instances on this control processor (CP). errDelimterSet Sets the error - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 59
module within the Fabric OS. supportFtp Sets, clears, or displays support FTP parameters or a time interval to check the FTP server. your switch service provider to diagnose and correct problems with the switch. The output from this command is very long. syslogDIpAdd Adds an IP address as - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 60
27: Port media incompatible. Reason: Configured port speed. 2004/07/28-17:04:54, [FABR-1001], 4,, WARNING, switch, port 4, ELP rejected by the other switch 2004/07/28-17:05:06, [FW-1050], 5,, WARNING, switch, Sfp Supply Voltage 0, is below low boundary(High=3600, Low=3150). Current value is 0 mV - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 61
Q to stop: 2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port media incompatible e. Reason: Configured port speed. Type to continue . To clear the system message log for a particular switch instance: 1. Log in to the switch as admin. 2. Use the errClear command to clear - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 62
(UTC) when the message was generated on the switch. The RASLog subsystem will support an internationalized timestamp format base on the "LOCAL" setting. [EM-1031] sequence number is persistent across power cycles and switch reboots. 1-8 Fabric OS Message Reference Publication Number: 53-1000242 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 63
the logical switch name. This field displays the defined switch name or the chassis name of the switch. This value is truncated if it is over 16 characters >, , / ///. /, , < - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 64
generated on the switch. The RASLog subsystem will support an internationalized timestamp format base on the as one of the following: Zone Security Configuration Firmware Fabric JohnSmith User ID Identifies the user ID. root .168.132.10 IP Address Identifies the IP address. Telnet Interface - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 65
, HA messages typically show the chassis name and login failures show the logical switch name. This field displays the defined switch name or the chassis name of the switch. This value is truncated if it is over 16 characters in length. Run either the chassisName command to name the chassis or - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 66
to be used as general guidelines for troubleshooting. For all cases, you should look longer operating in redundant mode unless the failed power supply is replaced or fixed. 4 = INFO on page 1-12 • "Gathering Information About the Problem" on page 1-13 • "Support" on page 1-13 • "Panic Dump and Core - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 67
the fabric redundant? 5. Run the errDump command on each logical switch. 6. Run supportFtp (as needed) to set up automatic FTP changes made to the system? Support There are a number of files created to help support personnel to troubleshoot and diagnose a problem This section describes those files - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 68
and core files are intended for support personnel use only. Trace Dumps The Fabric OS produces trace dumps when problems are encountered within Fabric OS modules show commands to provide a global output of the status of the switch. Refer to the Fabric OS Command Reference for more information on - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 69
the domain and alias lists to all switches in the fabric. FABS Fabric OS system driver module. FBC Firmware blade compatibility errors with CP. FCIP Fibre Channel over IP port configuration messages. FCMC Fibre Channel miscellaneous messages relate to problems with the physical layer used to - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 70
standby CP to take control of the switch nondisruptively during failures and software upgrades. These facilities include version negotiation, state as a component and a service. A component is a module in Fabric OS implementing a related set of functionality. A service is a collection of components - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 71
switch wide, but also fabric wide. It keeps track iSCSI VT status and updates VT status to BP. IPS Fibre Channel over IP license Name Server daemon (NSD) • PDM daemon (PDMD) • PS daemon (PSD) • Reliable commit service daemon (RCSD) • FA-API RPC daemon (RPCD) • Security daemon (SECD) • SNMP daemon - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 72
queued. Any process or interrupt service routine (ISR) can write messages blade to the standby CP blade. PDTR These messages indicate panic dump trace files have been created. PLAT This message indicates hardware problems. PORT PORT error messages refer to the front-end user ports on the switch - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 73
. Brocade switches support six management entities that can be configured to receive these traps. SS The supportSave command generates these error messages if problems are encountered. SULB The software upgrade library provides firmwareDownload command capability, which enables firmware upgrades - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 74
's Guide. TS Time Service provides fabric time-synchronization by synchronizing all clocks in the fabric to the clock time on the principal switch. UCST has an unexpected termination. WEBD Indicates problems with the Web Tools module. ZOLB Indicates problems with the zone library module. ZONE - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 75
RASLog Messages This section provides the RASLog messages, including: • AUTH System Messages • BL System Messages • BLL System Messages • BM System Messages • CDR System Messages • CER System Messages • CONF System Messages • EM System Messages • EVMD System Messages • FABR System Messages • FABS - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 76
• IBPD System Messages • ICPD System Messages • IPS System Messages • ISCS System Messages • ISNS System Messages • KSWD System Messages • KTRC System Messages • LOG System Messages • LSDB System Messages • MFIC System Messages • MPTH System - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 77
• WEBD System Messages • ZOLB System Messages • ZONE System Messages Fabric OS Message Reference I-3 Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 78
I-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 79
the secAuthSecret command. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1003 Message , [AUTH-1003], ,, INFO, , type has been successfully set - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 80
an authentication file corruption. Run the firmwareDownload command to reinstall the firmware. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1006 Message , [AUTH-1006], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 81
Severity Indicates an internal problem with the Secure Fabric ; then run the supportSave command and contact your switch service provider. WARNING AUTH-1007 Message , [AUTH not supported by the local specified port. Run the authUtil command to make sure the local switch supports the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 82
Action Severity Indicates an internal problem with the Secure Fabric OS. Reboot or power cycle the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1011 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 83
automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING AUTH-1014 Message , [AUTH-1014], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 84
set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1018 Message , [AUTH-1018], ,, was not created. Cause Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 85
particular value from the receiving payload. Usually this problem is transient. The authentication might fail. Reinitialize set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1023 Message , [AUTH-1023], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 86
phase. Usually this problem is transient. The switch does not support the specified authentication value. Check the authentication configuration and reset the supported transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1028 Message , [AUTH- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 87
set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1029 Message , [AUTH-1029], ,, structure that failed to get memory. Usually this problem is transient. The authentication might fail. Reinitialize - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 88
up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1031 Message , [AUTH-1031], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 89
set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1035 Message , [AUTH-1035], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 90
that the switch received an unexpected authentication message. Cause Recommended Action Usually this problem is transient. up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1037 Message , [AUTH-1037], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 91
and switchEnable commands. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR Fabric OS Message Reference Publication Number: 53-1000242-01 2-13 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 92
2 AUTH-1038 2-14 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 93
, [BL-1001], ,, INFO, , Port Initialization Completed. Probable Cause Recommended Action Severity Indicates that the switch has completed initializing the ports. No action is required. INFO BL-1002 Message , [BL-1002], , FFDC - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 94
in the specified slot number. Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that blade does not have hardware problems. Refer to the Fabric OS Command Reference for more information on - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 95
following the recommended removal procedure. Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Refer to the Fabric OS Command Reference for more - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 96
to initialize the ASIC chips. Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Refer to the Fabric OS Command Reference for more information - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 97
command to verify that the blade or switch does not have hardware problems. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power cycle the switch. If the message persists, replace the blade or the nonbladed switch. CRITICAL BL-1012 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 98
cable, SFP, or device attached to the specified port. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power cycle the switch. If the message persists, replace the blade. ERROR BL-1014 Message , [BL-1014], ,, ERROR - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 99
bladed switch or if errors are encountered again: • On the SilkWorm 12000, 24000, and 48000, replace the blade FRU blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 100
the chips. Probable Cause Recommended Action Severity Indicates that the switch has failed to initialize the ASIC chips. Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 101
. The switch is faulted. Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer Blade in slot was reset before blade init completed. As a result the blade is faulted. Probable Indicates that the blade was - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 102
power cycle the blade. If the message persists, replace the blade. CRITICAL BL-1024 Message , [BL-1024], ,, INFO, , All ports on the blade in slot will be reset as part of the firmware upgrade of the switch.The switch will Cause reboot and - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 103
power cycle the switch. If the message persists, replace the switch. CRITICAL BL-1029 Message , [BL-1029], ,, INFO, , All ports on the switch will be reset as part of the firmware upgrade. Probable Indicates that a recent firmware upgrade caused the switch - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 104
firmware upgrade. Probable Cause Recommended Action Severity Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade ports. Cause Recommended Power cycle the blade or run the slotPowerOff - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 105
that BE/BI ports have not come ONLINE within time limit. Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. If the message persists, replace the blade. Refer to the Fabric OS Command Reference for more information on the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 106
3 BL-1035 BL-1035 Message , [BL-1035], ,, INFO, , Slot iSCSI port Initialization Completed Probable Cause Recommended Action Severity Indicates that the indicated slot has completed initializing specified iSCSI port. No - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 107
that a blade regulation problem was reported on the specified slot number. The blade is faulted. All blade register fault Interrupt overrun • 13 = FDET interrupt • 14 = Interrupt suspended • 15 = Filter LISTD error • 16 = Unknown filter LIST error • 17 = Wait for LPC open state • 18 = Wait for - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 108
• 22 = BISR or RAMINIT error Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Refer to the Fabric OS Command Reference for more information on - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 109
the AP blade The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmwareDownload is supported between the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 110
to the BP to communicate. Reseat the blade. If the problem persists, power-cycle the blade using the slotPowerOff and slotPowerOn commands. WARNING BM-1004 Message , [BM-1004], ,, INFO, , Blade firmware on slot < Slot > is not consistent - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 111
,, WARNING, , Download of blade firmware failed for blade in slot . Reissue firmwaredownload to recover. Probable Cause Recommended Action The automatic firmware upgrade on the blade has failed because the blade firmware version was detected to be different from - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 112
processor failed. Cause Recommended Power-cycle the switch. Action Severity WARNING BM-1054 Message , [BM-1054], ,, INFO, , AP firmware is not consistent with system firmware . Auto-leveling AP firmware to match system - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 113
of AP firmware failed for the switch. Reissue firmwaredownload to recover. Probable Cause Recommended Action Severity The automatic firmware upgrade on the AP has failed because AP firmware was detected to be different from system firmware due to a firmware upgrade. Issue the firmwareDownload - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 114
5 BM-1058 5-6 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 115
Action Severity Internal error. All the ports on the blade or switch will be disrupted. For a bladed system, issue the slotPowerOff and slotPowerOn commands on the blade to recover the system. For a non-bladed system, perform fastBoot on the switch to recover the system. ERROR Fabric OS Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 116
6 CDR-1002 6-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 117
and standby CPs is broken because there is downlevel firmware loaded on the standby CP. The standby CP does not support the Advanced Performance Tuning module when FICON Management Server is enabled. Run the firmwareDownload command to upgrade the firmware on the standby CP. You can also disable FMS - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 118
7 CER-1001 7-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 119
CONF System Messages Chapter 8 CONF-1000 Message , [CONF-1000], , AUDIT, INFO, , configDownload completed successfully . Probable Cause Recommended Action Severity Indicates that the configDownload operation was initiated - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 120
again. INFO CONF-1022 Message , [CONF-1021], ,, INFO, , Downloading configuration without disabling the switch was unsuccessful. Probable Cause Recommended Action Severity Indicates that an attempt to download the configuration without disabling the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 121
are dumped to the console. Verify that the location temperature is within the operational range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Run the fanShow command to verify that all fans are running at normal speeds. If any fans - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 122
FRU is faulted. On SilkWorm 24000 and 48000, try reseating the specified FRU. Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on this command. On the SilkWorm - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 123
; the voltage is too low. If this problem occurs on a blade, it usually indicates a hardware problem on the blade; replace the blade. If this problem occurs on a switch, it usually indicates a hardware problem on the main board; replace the switch. CRITICAL EM-1007 Message , [EM-1007 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 124
SilkWorm 200E, 3016, 3250, 3850, 4100, and 4900 replace the switch. CRITICAL EM-1008 Message , [EM-1008], , FFDC to the SilkWorm 48000 Hardware Reference Manual for more information about chassisConfig modes and supported blades. CRITICAL EM-1010 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 125
faulted Probable Cause Recommended Action Severity Indicates that a switch blade or nonbladed switch failed to transition from one state to another. It persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 126
Action Severity Indicates that a problem was discovered when performing consistency checks during a warm boot. A reboot or power cycle is required to clear Action Indicates that a problem was discovered when performing consistency checks during a cold boot. Monitor the switch. 9-6 Fabric OS - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 127
command and contact your switch service provider. WARNING EM-1017 power cycle, or firmwareDownload operation. Change and commit the new WWN value. WARNING EM-1018 Message , [EM-1018], , FFDC, CRITICAL, , CP blade is not supported by the firmware on the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 128
option to 1 with the chassisConfig command, or upgrade the firmware on the standby to the version running on the problem. The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or port. If the message persists, reboot or power cycle the switch - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 129
, or completely screw in the upper thumbscrew for the FC4-48 port blade) if the FRU is intended for use. Refer to the appropriate hardware manual for instructions on inserting the switch blades. ERROR EM-1033 Message , [EM-1033], ,, ERROR, , CP in - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 130
If the FRU is a WWN card, then default WWN and IP addresses are used for the switch. Reseat the FRU card. If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 131
Severity Indicates that the specified Power Supply has been marked as no longer being faulty. Probably because its AC power supply has been turned on. RPM If the message is isolated, monitor the error messages on the switch. If the message is associated with other messages, follow the recommended - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 132
>, Can't power on , its logical switch is shut blade. If new_state is On, a port blade is being powered on because more power is available (either a power supply was inserted or a port blade was removed or powered down). If new_state is Off, a port blade has been powered down because a power - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 133
blades installed, two power supplies are sufficient for redundancy; however, when one or more AP blades have been installed, four power supplies access recovered: state Probable Indicates that the I2C bus problems have been resolved and I2C access to the FRU has become Cause - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 134
9 EM-1049 Recommended Action Severity The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is displayed. INFO EM-1049 Message , [EM-1049], ,, INFO, , FRU insertion detected. Probable - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 135
the port media is extended long wavelength, move it to a port that can support the heat generated. WARNING EM-1056 Message , [EM-1056], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 136
is not supported by the release on the standby CP. Please remove all blades of this type or upgrade your standby CP. Once an appropriate action is taken, this CP must be rebooted or haSyncStart must be run successfully. Until this is done, the system will remain out of synchronization. WARNING 9-16 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 137
your standby CP, then reboot or run haSyncStart. Probable Cause Recommended Action Severity A blade in the system is not supported by the release on the standby CP. Please remove all blades of this type or upgrade your standby CP. Once an appropriate action is taken, this CP must be rebooted - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 138
slot will be 0 for non-bladed systems. On bladed systems, try reseating the specified FRU. On nonbladed switches, reboot or power cycle the switch. If the problem persists: • Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 139
], ,, WARNING, , Event could not be sent to remote proxy. = Probable The event could not be sent to the remote proxy because the remote proxy switch cannot be reached Cause through in-band. Recommended Please make sure that the specified remote - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 140
10 EVMD-1001 10-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 141
, Probable Cause Recommended Action Severity Indicates that the specified switch port is isolated because of a segmentation due to mismatched configuration parameters. Based on the segmentation reason displayed within the message, look for a possible mismatch of - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 142
Action Severity Indicates that an internal link service (ILS) information unit of invalid size has been received. The neighbor switch has sent an invalid sized payload. Investigate the neighbor switch for problems. Run the errShow command on the neighbor switch to view the error log for additional - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 143
FTP transfers; then run the supportSave command and contact your switch service provider. WARNING FABR-1006 Message , [FABR-1006], that has already been deallocated. This message is rare and usually indicates a problem with the Fabric OS. In case of severe memory corruption, the system - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 144
to a faulty EFP type. This message is rare and usually indicates a problem with the Fabric OS. The fabric daemon will discard the EFP. The system automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING FABR-1010 Message , [FABR-1010], < - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 145
or unstable. This message is rare and usually indicates a problem with the Fabric OS. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR FABR-1012 Message , [FABR-1012 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 146
is rare and usually indicates a problem with the Fabric OS. The system will recover by failing over to the standby CP. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. CRITICAL FABR-1014 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 147
, [FABR-1017], ,, WARNING, , ficonMode is disabled. Probable Indicates that FICON mode is disabled on the switch through a user interface command. Cause Recommended No action is required. Action Severity WARNING FABR-1018 Message , [FABR-1018 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 148
supported configuration () Probable Cause Recommended Action Severity Indicates that this switch is a value-line switch must be changed to within the licensed limit. Contact your switch provider to obtain a full fabric license. CRITICAL FABR-1020 Message , [FABR- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 149
changed to within the licensed limit. Contact your switch provider to obtain a full fabric license. CRITICAL FABR-1023 Message , [FABR-1023], ,, INFO, , Fabric size is within supported configuration (). Fabric limit timer () stopped - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 150
must be changed to within the licensed limit. Contact your switch provider to obtain a full fabric license. INFO FABR-1029 Message , [FABR- mode. In both of the previous modes, the buffer credits are fixed, based on the port configuration information. In this mode, the buffer credits are - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 151
FABR-1031 11 Probable Cause Recommended Action Severity Indicates that the domain ID has changed as specified. No action is required. INFO FABR-1031 Message , [FABR-1031], , FFDC, WARNING, , Maximum number of retries sending ILS from port - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 152
11 FABR-1031 11-12 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 153
has been detected by the software. This is usually an internal Fabric OS problem or file corruption. Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. WARNING FABS-1004 Message , [FABS-1004], ,, WARNING - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 154
This is usually an internal Fabric OS problem or file corruption. Reboot or power cycle the switch. WARNING FABS-1005 Message , [FABS : failed sending media state to blade driver If the message is isolated, monitor the error messages on the switch. If the error is repetitive - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 155
value in an object's status field. This is usually an internal Fabric OS problem or file corruption. Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. WARNING FABS-1008 Message , [FABS-1008], ,, WARNING - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 156
an unknown event type. This is usually an internal Fabric OS problem or file corruption. Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. WARNING FABS-1011 Message , [FABS-1011], ,, ERROR, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 157
FRU header, or the blade may not be supported by this platform or Fabric OS version. Verify that the blade is valid for use in this system and this version of Fabric OS. Try reseating the blade. If this is a valid blade and reseating does not fix the problem, then replace the blade. ERROR FABS-1014 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 158
could not be enabled. This is usually an internal Fabric OS problem. Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. ERROR 12-6 Fabric OS Message Reference Publication Number: 53-1000242 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 159
the CP. The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmwareDownload is supported between the versions - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 160
13 FBC-1001 13-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 161
FCIP System Messages Chapter 14 FCIP-1000 Message , [FCIP-1000], , FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= rsn= fn= oid= - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 162
14 FCIP-1000 14-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 163
is low on memory and failed to allocate new memory for an information unit (IU). A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically fail over and the standby CP will become the active CP. CRITICAL Fabric OS Message Reference Publication Number - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 164
15 FCMC-1001 15-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 165
16 FCPD-1001 Message , [FCPD-1001], ,, WARNING, , Probing failed on Probable Cause Recommended Action Severity Indicates that an FCP switch for a firmware upgrade containing a defect fix. The SilkWorm 4100 does not support private loop - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 166
Cause Recommended Action Severity Private devices will not respond to the switch PLOGI during probing. Refer to the switch vendor for a list of other port types that support private devices for inclusion into the fabric. INFO 16-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 167
. The failed function call is "kmalloc_wrapper failed". This function call is for kernel memory allocation. A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically fail over, and the standby CP will become the active CP. CRITICAL Fabric OS Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 168
17 FCPH-1001 17-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 169
FCR System Messages Chapter 18 FCR-1001 Message , [FCR-1001], ,, INFO, , FC router proxy device in edge created at port . Probable Indicates that a proxy device in the edge fabric has been imported at the specified port. Cause Recommended No - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 170
18 FCR-1004 Recommended Action Severity No action is required. INFO FCR-1004 Message , [FCR-1004], ,, INFO, , FC router physical device offline at port . Probable Cause Recommended Action Severity Indicates that a physical device connected - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 171
FCR-1007 18 Severity INFO FCR-1007 Message , [FCR-1007], ,, INFO, , FC router LSAN zone removed at port . Probable Cause Recommended Action Severity Indicates that an LSAN zone attached to the specified port was removed from the edge fabric - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 172
18 FCR-1010 FCR-1010 Message , [FCR-1010], ,, INFO, , FC router LSAN zone disabled at port . Probable Cause Recommended Action Severity Indicates that an LSAN zone is disabled in the edge fabric. No action is required. INFO FCR-1011 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 173
number> fabric ID . Probable Indicates that a fabric is no longer accessible through the backbone fabric. This can be caused by a link Cause or switch failure. Recommended No action is required. Action Severity INFO Fabric OS Message Reference Publication Number: 53-1000242-01 18-5 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 174
device port resources. Use the fcrProxyDevShow command to view how many proxy devices are created in the fabric with the port resource problem. LSAN zones are removed using standard zoning commands such as zoneShow, zoneRemove, zoneDelete, cfgDelete, and cfgDisable in the edge fabric. Proxy devices - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 175
FCR-1021 18 Recommended Action Severity Remove excess LSAN zones so that the number of LSAN zones created is within the range of the local database limitations. WARNING FCR-1021 Message , [FCR-1021], ,, WARNING, , Local LSAN device entries exhausted. - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 176
18 FCR-1024 Recommended Action Severity You might need to limit the number of port WWNs required by limiting the remote edge fabric connectivity (which limits the number of translate domains). You can also limit the number of proxy devices for a translate domain (which limits the number of - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 177
detected to not be in use are reused as needed. It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of LSAN devices and fabrics, or there are highly dynamic changes to EX_Port connectivity. WWN - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 178
detected to not be in use are reused as needed. It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of LSAN devices and fabrics, or there are highly dynamic changes to EX port connectivity - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 179
FCR-1032 18 FCR-1032 Message , [FCR-1032], ,, INFO, , Edge fabric enabled security on port in fabric . Probable Cause Recommended Action Severity Indicates that Secure mode was turned on in the edge fabric. No action is required. - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 180
18 FCR-1035 FCR-1035 Message , [FCR-1035], ,, INFO, , LSAN zone device added in the backbone fabric. Probable Cause Recommended Action Severity Indicates that a new device was added to an LSAN zone in the backbone fabric. No action is required. INFO FCR- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 181
>. Probable Cause Recommended Action Severity Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the local switch's zone database limitations. Remove excess cfg/zone/alias entries so that the number of LSAN zones created is within the range of the local - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 182
18 FCR-1041 FCR-1041 Message , [FCR-1041], ,, INFO, , LSAN zone device removed in the backbone fabric. Probable Cause Recommended Action Severity Indicates that an LSAN zone device within the backbone fabric was removed. No action is required. INFO FCR- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 183
Severity Indicates that an incoming ELP command was issued and it is not supported. Run the portEnable and portDisable commands to enable and disable the port. If the problem persists contact your switch service provider. ERROR FCR-1053 Message , [FCR-1053], ,, WARNING - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 184
information using the supportShow command, and contact your switch service provider. WARNING FCR-1055 Message , [FCR-1055], ,, INFO, , Switch with domain ID does not support backbone to edge imports. Probable Cause Recommended Action Severity - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 185
FCR-1057 18 Recommended Action Severity No action is required if backbone to edge routing is not needed. Otherwise replace the switch with one that supports backbone to edge routing. INFO FCR-1057 Message , [FCR-1057], ,, ERROR, , EX port() - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 186
>, EX port() has an incompatible configuration setting. Probable Cause Recommended Action Severity Indicates that VC Link Init is enabled on the local switch and the remote switch is negotiating in R_RDY mode. The fabric might not form properly. Check the configuration on the local - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 187
the maximum number of supported ports was exceeded. To enable this port, disable any other operational port then re-enable the port. No action is required. INFO FCR-1063 Message , [FCR-1063], ,, INFO, , Fabric for switch with domain ID: - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 188
Recommended Action Severity Indicates that another port on the switch is connected to the same edge fabric with If the fabric split, then merge the fabrics and manually re-enable the port. If there is another fabric connected fabric exceeds the maximum number supported by the Fibre Channel. The - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 189
configDownload with the fcrState set to 2 (disabled). Note that the FC Routing service is disabled by the factory. No action is required. INFO FCR-1069 FC Routing configuration is set to default. Probable Indicates that the FC Routing configuration is set to default by user. This removes all old - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 190
Probable Cause Recommended Action Severity Indicates that a switch in the backbone/edge that supports different limit of LSAN Zones was detected. Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest supported LSAN zone limits. Please make sure that total - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 191
for this RNID. The error variable is an internal error number. If this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference for more - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 192
is not installed on the switch. Run the licenseShow command to check the installed licenses on the switch. The switch cannot be managed using FICON fmsmode using the ficoCupSset command. Refer to the Fabric OS Administrator's Guide for information on core PID mode and the Fabric OS Command Reference - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 193
Download a new firmware version using the problem. If the message persists, check the memory usage on the switch , using the memShow command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 194
to enable FICON Management Server mode (fmsMode) were not available on some of the ports. Use the perfDelFilterMonitor command to delete the filter-based performance monitors used on all ports to free up the resources. WARNING FICU-1010 Message , [FICU-1010], ,, WARNING - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 195
FKLB System Messages Chapter 20 FKLB-1001 Message , [FKLB-1001], ,, WARNING, , exchange overlapped, pid= Probable Cause Recommended Action Severity Indicates that the FC kernel driver has timed out the exchange while the application is still - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 196
20 FKLB-1001 20-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 197
FLOD System Messages Chapter 21 FLOD-1001 Message , [FLOD-1001], , FFDC, WARNING, , Unknown LSR type: port , type Probable Cause Recommended Action Severity Indicates that the link state record (LSR) type is unknown. 1- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 198
Action Severity Indicates that the LSU size exceeds what the system can support. Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two switches. ERROR FLOD-1005 Message , [FLOD-1005], ,, WARNING, , Invalid - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 199
port number> out of range Probable Indicates that the specified input port number is out of range; it does not exist on the switch. Cause Recommended No action is required. Action Severity ERROR FSPF-1002 Message , [FSPF-1002], ,, INFO, , Wrong neighbor ID - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 200
ID. It should be set to 0 for a nonhierarchical fabric. SilkWorm switches support only section ID 0. Use a frame analyzer to verify that the reported the firmwareDownload command to update the firmware to the latest version. All current versions of the Fabric OS support FSPF version 2, which is the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 201
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING FSS-1002 Message , [FSS-1002], ,, WARNING, , Component () sending too many concurrent - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 202
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR FSS-1005 Message , [FSS-1005], ,, WARNING, , FSS read failure Probable Indicates that the read - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 203
Cause Recommended Action Severity Indicates that the Ethernet connection is not healthy. Check the Ethernet connection and issue the haSyncStart command. If the problem persists, contact your switch service provider. CRITICAL Fabric OS Message Reference Publication Number: 53-1000242-01 23-3 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 204
23 FSS-1007 23-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 205
on the active CP and try resynchronizing the HA state. If the HA state does not become synchronized, run the haDump command to diagnose the problem. WARNING Fabric OS Message Reference Publication Number: 53-1000242-01 24-1 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 206
CP fails, the failover will be disruptive. In a non-bladed system, this message is logged when the firmware upgrade/downgrade was invoked. The new firmware version is not compatible with current running version. This cause a disruptive firmware upgrade/ downgrade. For a dual CP system, run the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 207
that the fans and airflow of a switch are functioning normally. Verify that the location temperature is within the operational range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. WARNING Fabric OS Message Reference Publication Number - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 208
Probable Cause Recommended Action Severity Indicates that the internal temperature of the switch has changed from a value outside of the acceptable range to a the speed of the fan has changed. Fan problems typically contribute to temperature problems. No action is required. Respond to this - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 209
>. Probable Cause Recommended Action Severity Indicates that the speed of the fan has fallen below the low boundary. Fan problems typically contribute to temperature problems. Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan FRU. WARNING FW-1007 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 210
that it is seated correctly in the chassis. Run the psShow command to view the status of the power supply. If the power supply continues to be a problem, replace the faulty power supply. INFO FW-1010 Message , [FW-1010], ,, WARNING, , , is below low - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 211
and low boundaries(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the power supply counter changed from a value outside of the acceptable range to a value within the acceptable range. No action is required. Respond to - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 212
INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the receive power value of the SFP has changed. The receive performance area measures the amount of incoming laser to help you determine if the SFP is - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 213
is below low boundary(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the receive power value of the SFP has fallen below the low boundary. The receive performance area measures the amount of incoming laser to help you - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 214
value has changed(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the transmit power value of the SFP has changed. The transmit performance area measures the amount of outgoing laser to help you determine if the SFP is - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 215
above high boundary(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the transmit power value of the SFP has risen above the high boundary. The transmit performance area measures the amount of outgoing laser to help you - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 216
25 FW-1046 Severity INFO FW-1046 Message , [FW-1046], ,, WARNING, , , is below low boundary(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the value of the SFP - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 217
FW-1049 25 Severity INFO FW-1049 Message , [FW-1049], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Indicates that the value of the SFP voltage has changed. Frequent voltage - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 218
SFP. SFP failures also cause E_Ports to go down. E_Port downs might be caused by transient errors. A low number of E_Port failures means that the switch is functioning normally. 25-12 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 219
FW-1115 25 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1115 Message , [FW-1115], ,, INFO, , , is above high boundary(High=, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 220
. The following actions can cause a fabric reconfiguration: • two switches with the same domain ID have connected to one another. • inexplicable fabric reconfiguration might be a transient error and might not require troubleshooting. INFO FW-1118 Message , [FW-1118], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 221
fabric reconfiguration might be a transient error and might not require troubleshooting. INFO FW-1120 Message , [FW-1120], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 222
single fabric and the principal switch has to assign another domain ID to the switch. A low number of fabric and the principal switch has to assign another domain ID to the switch. No action is fabric and the principal switch has to assign another domain ID to the switch. No action is required - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 223
. Segmentation changes might occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. No action - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 224
. Segmentation changes might occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. No action - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 225
FW-1129 25 FW-1129 Message , [FW-1129], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of zone changes has changed. Zone - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 226
25 FW-1132 FW-1132 Message , [FW-1132], ,, INFO, , , is between high and low boundaries(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of zone changes has - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 227
FW-1135 25 FW-1135 Message , [FW-1135], ,, INFO, , , is above high boundary(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of fabric logins has risen above - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 228
below the low boundary. SFP state changes occur when the SFP is inserted or removed. A low number of SFP state changes means that the switch is functioning normally. No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 229
physical and hardware problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch is functioning normally - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 230
problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot synchronization loss errors, troubleshoot your HBA and contact your switch service provider. INFO 25- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 231
. Verify that the cable and SFPs are not faulty. If you continue to experience loss-of-synchronization errors, troubleshoot your HBA and contact your switch service provider. WARNING FW-1167 Message , [FW-1167], ,, INFO, , , , is between - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 232
below the low boundary. Loss of signal generally indicates a physical problem. No action is required. Respond to this message as is appropriate end-user installation. A low number of signal loss errors means that the switch is functioning normally. INFO FW-1170 Message , [FW-1170], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 233
. Respond to this message as is appropriate to the particular policy of the end-user installation. Frequent loss of signal generally indicates a physical problem. Check both ends of your cable connection. Verify that the cable and SFPs are not faulty. INFO FW-1172 Message , [FW-1172 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 234
the low boundary. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. No action is required. Respond to this message as is appropriate to the particular - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 235
words that the port experiences has fallen below the low boundary. Invalid words usually indicate a hardware problem with an SFP or cable. A low number of invalid words means that the switch is functioning normally. No action is required. Respond to this message as is appropriate to the particular - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 236
range to a value within the acceptable range. Invalid words usually indicate a hardware problem with an SFP or cable. No action is required. Respond to this message as low number of invalid CRCs means that the switch is functioning normally. Severity INFO 25-30 Fabric OS Message Reference Publication - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 237
FW-1182 25 FW-1182 Message , [FW-1182], ,, WARNING, , , , is above high boundary(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of invalid CRCs - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 238
the acceptable range. No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO 25-32 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 239
FW-1188 25 FW-1188 Message , [FW-1188], ,, INFO, , , , value has changed(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the percentage of outgoing traffic - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 240
faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. A low number of port state changes means that the switch is functioning normally. 25-34 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 241
FW-1194 25 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1194 Message , [FW-1194], ,, WARNING, , , , is above high boundary( - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 242
should set your high boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem in this area. A low level of invalid CRC errors means that the switch is functioning normally. No action is required. Respond to this message as is appropriate to the particular policy - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 243
, temperature fluctuations, and aging equipment. You should set your high boundaries to fiveor six-digit figures, as only large numbers of messages indicate a problem in this area. No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 244
25 FW-1242 Probable Cause Recommended Action Severity Indicates that the number of EE CRC errors has fallen below the low boundary. Invalid CRC messages occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID) and destination ID (D_ID) pairs change. These messages - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 245
Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of EE word frames that the switch receives has changed. Receive performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 246
>, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of EE word frames that the switch transmits has changed. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 247
=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of EE word frames that the switch transmits has risen above the high boundary. Transmit performance messages appear due to the number of word frames that travel from the configured - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 248
has received SCSI Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a frame. No action is required. Respond to this message as is has received SCSI Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a frame. No action is required. Respond to this message as is - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 249
indicate that a telnet connection request has been received from an unauthorized IP address. The TELNET_POLICY contains a list of TCP/IP addresses that are authorized to establish telnet connections to switches in the fabric. The IP addresses use standard "dot" notation (for example, 255.255.255.255 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 250
indicate that a telnet connection request has been received from an unauthorized IP address. The TELNET_POLICY contains a list of TCP/IP addresses that are authorized to establish telnet connections to switches in the fabric. The IP addresses use standard "dot" notation (for example, 255.255.255.255 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 251
indicate that a browser connection request has been received from an unauthorized IP address. The HTTP_POLICY contains a list of TCP/IP addresses that are authorized to establish browser connections to the switches in the fabric. The IP addresses use the standard "dot" notation (for example, 255.255 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 252
indicate that an API connection request has been received from an unauthorized IP address. The SNMP_POLICY contains a list of TCP/IP addresses that are authorized to establish API connections to switches in the fabric. The IP addresses use standard "dot" notation (for example, 255.255.255.255). Run - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 253
indicate that an API connection request has been received from an unauthorized IP address. The SNMP_POLICY contains a list of TCP/IP addresses that are authorized to establish API connections to switches in the fabric. The IP addresses use standard "dot" notation (for example, 255.255.255.255). Run - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 254
unauthorized IP address. The SNMP_POLICY contains a list of TCP/IP addresses that are authorized to establish API connections to switches in the fabric. The IP addresses use been received from an unauthorized IP address. No action is required. INFO 25-48 Fabric OS Message Reference Publication Number: 53 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 255
range to a value within the acceptable range. RSNMP violations indicate that an SNMP "get" operation request has been received from an unauthorized IP address. No action is required. INFO FW-1312 Message , [FW-1312], ,, INFO, , , value has changed - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 256
below the low boundary. WSNMP violations Cause indicate that an SNMP "get/set" operation request has been received from an unauthorized IP address. Recommended No action is required. Action Severity INFO FW-1314 Message , [FW-1314], ,, WARNING, , - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 257
SES violations has changed. SES violations indicate that an SCSI Enclosure Services (SES) request has been received from an unauthorized WWN. The the SES Server functionality. Run the errShow command to determine the IP address that sent the request. Responses to security class messages depend - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 258
Recommended Action Severity Indicates that the number of SES violations has risen above the high boundary. SES violations indicate that an SCSI Enclosure Services (SES) request has been received from an unauthorized WWN. The SES_POLICY contains a list of WWNs of device ports that are allowed to - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 259
FW-1321 25 FW-1321 Message , [FW-1321], ,, INFO, , , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of MS violations has fallen below the low boundary. MS - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 260
number of serial violations has changed. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch WWNs for which serial port access is enabled. Run the errShow command to determine the WWN of the device that sent the request - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 261
serial port request has been received. The SERIAL_POLICY contains a list of switch WWNs for which serial port access is enabled. Run the errShow command panel request has been received. The FRONTPANEL_POLICY contains a list of switch WWNs for which front panel access is enabled. Run the errShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 262
risen above the high boundary. Front panel violations indicate that an unauthorized front panel request has been received. The FRONTPANEL_POLICY contains a list of switch WWNs for which front panel access is enabled. Run the errShow command to determine the WWN of the device that sent the request - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 263
Indicates that the number of SCC violations has fallen below the low boundary. SCC violations indicate that an unauthorized switch tried to join the fabric. The SCC_POLICY contains a list of switches by WWN that are allowed to be members of a fabric. No action is required. INFO FW-1334 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 264
device tried to join the fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs an FLOGI request, the WWN specified in the FLOGI is validated to be connected to - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 265
of rules for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs an FLOGI request of rules for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs an FLOGI request - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 266
specification of rules for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs an FLOGI request has been detected. Run the errShow command to determine the IP location of the login attempt. Responses to securityclass messages depend - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 267
has been detected. Run the errShow command to determine the IP location of the login attempt. Responses to securityclass messages depend downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 268
from the primary FCS. When the primary fabric configuration server (FCS) downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference is too great, it rejects the packet - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 269
in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 270
has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid signatures. No action is required. 25-64 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 271
from the primary FCS. Before a new primary FCS switch sends any configuration data to any switch in the fabric, it first sends its certificate to all the switches in the fabric. The receiving switch has to verify that the sender is the primary FCS switch and its certificate is signed by the Root CA - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 272
from the primary FCS. Before a new primary FCS switch sends any configuration data to any switch in the fabric, it first sends its certificate to all the switches in the fabric. The receiving switch has to verify that the sender is the primary FCS switch and its certificate is signed by the Root CA - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 273
Severity Indicates that the number of authentication failures has changed. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly, or send unexpected packets. The port where authentication - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 274
outside of the acceptable range to a value within the acceptable range. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 275
(High=, Low=). Current value is . Probable Cause Recommended Action Indicates that the number of time service (TS) out-of-sync violations has changed. Responses to security-class messages depend on user policies. Consult your security administrator for response - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 276
Label>, is below low boundary(High=, Low=). Current value is . Probable Indicates that the number of time service out-of-sync violations has fallen below the low boundary. Cause Recommended No action is required. Action Severity INFO FW-1366 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 277
has changed. This counter records how often the switch loses contact with the primary FCS switch. When the primary FCS switch in the fabric sends its certificate to a switch, the receiving switch saves the WWN of that primary FCS switch. If a secure switch finds that there are no FCSs in the fabric - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 278
the high boundary. This counter records how often the switch loses contact with the primary FCS switch. When the primary FCS switch in the fabric sends its certificate to a switch, the receiving switch saves the WWN of that primary FCS switch. If a secure switch finds that there are no FCSs in the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 279
has fallen below the low boundary. This violation indicates the number of secure switches with different version stamps have been detected. When a switch is in secure mode, it connects only to another switch that is in secure mode and has a compatible security database. A compatible security - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 280
the low boundary. This counter tracks how many times commands allowed only on the primary FCS switch have been executed on a nonprimary FCS switch. There are many commands that can be executed only on the primary FCS switch as well as one security command that can be executed only on a backup FCS - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 281
value is . Probable Indicates that the flash usage percentage has changed. Flash increases and decreases slightly with Cause normal operation of the switch. Excessive permanent increases can lead to future problems. Fabric OS Message Reference Publication Number: 53-1000242-01 25-75 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 282
flash usage percentage has risen above the high boundary. Flash increases and decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. You might have to remove some unwanted files to create some flash space. Run the saveCore command to remove - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 283
decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. No action is required. Respond to FW-1426], ,, WARNING, , Switch status change contributing factor Power supply: bad, absent - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 284
FW-1427 Message , [FW-1427], ,, WARNING, , Switch status change contributing factor Power supply: bad. Probable Cause Recommended Action Severity Indicates that the switch status is not in a healthy state. This occurred because the number of - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 285
FW-1430 25 Probable Cause Recommended Action Severity Indicates that the switch status is not in a healthy state. This occurred because the power supplies are not in the correct slots for redundancy. Rearrange the power supplies so that one is in an odd slot and other in an even slot to make them - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 286
levels. Run the firmwareDownload command to install the same level of firmware to both CPs. Replace any faulty CPs. If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was up on a power cycle, and the CPs came up non-redundant, then you should reboot - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 287
Marginal ports: marginal ports. (Port(s) ) Probable Cause Recommended Action Severity Indicates that the switch status is not in a healthy state. This occurred because the number of marginal ports is greater than or equal to the policy set - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 288
change contributing factor Missing SFPs: missing SFPs. Probable Indicates that the switch status is not in a healthy state. This occurred because the number of missing Cause SFPs is greater than or equal to the policy set by - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 289
Probable Cause Recommended Action Severity Indicates that specified FRU's state has changed to "inserted". This means that a FRU is inserted but not powered on. No action is required. Verify that the event was planned. INFO FW-1442 Message , [FW-1442], ,, INFO, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 290
switch now requires 4 power supplies for full (2X) redundancy, but the user has previously overridden the Switch Status Policy values pertaining to number of power supplies. So those values will not be automatically changed. The default values with no AP blades are: 3 out of service indicates switch - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 291
FW-1500 25 Recommended Action Severity To maintain full (2X) redundancy and proper monitoring by Fabric Watch, 4 active power supplies should be supplied and the default values associated with the presence of an AP blade should be entered with switchstatuspolicyset. WARNING FW-1500 Message < - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 292
25 FW-1501 25-86 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 293
normally, but because the standby CP is not healthy, nondisruptive failover is not possible. Reboot the standby CP blade by ejecting the card and reseating it. If the problem persists, replace the standby CP. CRITICAL HAM-1002 Message , [HAM-1002], ,, INFO, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 294
>, Processor rebooted - Probable Cause Recommended Action Severity This message records switch processor reboot reasons that were initiated by the user or the switch errors. The switch reboots can be initiated by the firmwareDownload, fastBoot, haFailover, and reboot commands. Some - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 295
switch service provider with the supportSave and haDump information. CRITICAL HAMK-1002 Message , [HAMK-1002], ,, INFO, , Heartbeat down Probable Cause Recommended Action Severity Indicates that the active CP blade determined that the standby CP blade - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 296
>, [HAMK-1003], ,, INFO, , Heartbeat up Probable Cause Recommended Action Severity Indicates that the active CP blade detects the standby CP blade. This message indicates that the standby CP blade is available to take over in case a failure happens on the active CP - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 297
() is above threshold. Probable Cause Recommended Action Severity Indicates that the blade voltage is above the threshold. Replace the faulty blade or switch (for nonbladed switches). ERROR HIL-1102 Message , [HIL-1102], ,, ERROR, , Slot - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 298
FRU to verify that they are seated properly. If the problem persists, replace the fan FRU or the power supply FRU as necessary. ERROR HIL-1105 Message , [HIL-1105], ,, ERROR, , Switch error, () above threshold. Probable - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 299
For the SilkWorm 3900, replace the motherboard FRU. For the SilkWorm 4100, if the 12 volt level is faulty, replace one or both power supplies; if any other voltage is faulty, replace the entire switch. ERROR HIL-1107 Message , [HIL-1107], , FFDC, CRITICAL, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 300
. Make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. If the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 301
. Make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. If the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 302
the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Use - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 303
that a fan FRU has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Replace the affected fan FRU immediately. WARNING HIL-1302 Message , [HIL-1302], ,, WARNING, , - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 304
28 HIL-1303 HIL-1303 Message , [HIL-1303], ,, ERROR, , One fan failed. Replace failed fan FRU immediately. Probable Cause Recommended Action Severity Indicates that a fan FRU has failed. This message is often preceded by a low fan speed message. Replace - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 305
HIL-1306 28 HIL-1306 Message , [HIL-1306], ,, ERROR, , Three fans failed. Replace failed fan FRUs immediately. Probable Cause Recommended Action Severity Indicates that three fan FRUs have failed. This message is often preceded by a low fan speed message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 306
that one or more fans has failed. This message only occurs on the SilkWorm 200E. It follows a previous indication of faultiness. Replace the switch because the fan is not field replaceable. WARNING HIL-1311 Message , [HIL-1311], ,, INFO, , No fans are - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 307
HIL-1401 28 HIL-1401 Message , [HIL-1401], ,, WARNING, , One fan FRU missing. Install fan FRU immediately. Probable Cause Recommended Action Severity Indicates that one fan FRU has been removed. Install the missing fan FRU. WARNING HIL-1402 Message < - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 308
is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Severity . Probable Cause Recommended Action Indicates that the temperature of this blade has risen above the critical threshold. This usually follows a high - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 309
and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the blade. CRITICAL HIL-1503 Message , [HIL-1503], , FFDC, CRITICAL - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 310
sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. WARNING HIL-1506 Message , [HIL-1506], , FFDC, CRITICAL, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 311
fan is not field-replaceable. To help prevent future problems, make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. CRITICAL HIL-1509 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 312
system can continue operation. To help prevent future problems, make sure that all the fans are working manual for your switch for the operational temperature range. WARNING HIL-1601 Message , [HIL-1601], ,, ERROR, , Using backup temperature sensor. Service - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 313
HIL-1602 28 Severity Run the tempShow command to verify temperature values. If any sensor is too high, monitor the switch. Try rebooting or power cycling the switch. CRITICAL Fabric OS Message Reference Publication Number: 53-1000242-01 28-17 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 314
28 HIL-1602 28-18 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 315
Cause Recommended Action Severity Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The Brocade switch will not accept FSPF frames from the remote switch. In the Fabric OS, the HLO dead timeout value is not configurable, so this error can only occur when - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 316
Cause Recommended Action Severity Indicates that the HLO message received was invalid and the frame was dropped. The Brocade switch will not accept FSPF frames from the remote switch. The switch has received an invalid HLO because either the domain or port number in the HLO message has an invalid - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 317
. Run the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. CRITICAL Fabric OS Message Reference Publication Number - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 318
30 HMON-1001 30-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 319
>, [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Recommended . For more information on PID, format refer to the Fabric OS Administrator's Guide. INFO HTTP-1002 Message , [HTTP-1002], , AUDIT, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 320
31 HTTP-1003 Probable Cause Recommended Action Severity Indicates an error in completing the zoning transaction. Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 321
IBPD System Messages Chapter 32 IBPD-1001 Message , [IBPD-1001], ,, WARNING, < character limit [] Probable Indicates that the target name length exceeds the supported limit. Cause Recommended Redo the discovery to get the latest target list, and - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 322
exceed the maximum limit at slot port ge Probable Cause Recommended Action Severity Indicates that the iSCSI login sessions exceed the supported limit per port. Use another port to login. WARNING 32-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 323
power cycle the switch. ERROR ICPD-1002 Message , [ICPD-1002], ,, ERROR, , Failed to initialize rc = . Probable Cause Recommended Action Severity Indicates that an initialization of a module within the ICPD failed. Download a new firmware - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 324
command. WARNING ICPD-1006 Message , [ICPD-1006], ,, INFO, , iSCSI service is on the switch. Probable Indicates that the iSCSI service is enabled or disabled on the switch. Cause 33-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 325
Message , [ICPD-1007], ,, INFO, , iSNSC service is on the switch. Probable Cause Recommended Action Severity Indicates that the iSNSC service is enabled or disabled on the switch. No action is required. INFO ICPD-1008 Message , [ICPD - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 326
33 ICPD-1008 33-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 327
switch. WARNING IPS-1002 Message , [IPS-1002], ,, ERROR, , Failed to initialize rc = Probable Cause Recommended Action Severity Indicates that an initialization of a module within the IPS daemon failed. Download a new firmware version - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 328
a transient problem. If the message persists, check the memory usage on the switch, using the memShow command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING IPS-1004 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 329
IPS-1006 34 Probable Cause Recommended Action Severity Indicates that tunnel setup failed due to a configuration mismatch between the two ends. Reasons for such a mismatch could - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 330
34 IPS-1006 34-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 331
ISCS System Messages Chapter 35 ISCS-1000 Message , [ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Indicates that specified port has crashed. Cause Recommended No action is required; the port will restart - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 332
35 ISCS-1000 35-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 333
INFO ISNS-1002 Message , [ISNS-1002], ,, INFO, , Start peering with external iSNS server slot/port /. Probable Indicates that peering has started with the specified external iSNS server. Cause Recommended - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 334
iSNS server is disabled. Probable Cause Recommended Action Severity Indicates that the IP address of iSNS server is set to zero, so peering is disabled. User request re-register with external iSNS server slot/port /. Probable Indicates that - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 335
, Peering with external iSNS server not started because configuration unchanged. Probable Indicates that peering INFO, , Peering with external iSNS server not started because no virtual targets found. Probable Indicates - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 336
a valid slot/port. Refer to the appropriate hardware reference manual for valid slot and port ranges. WARNING ISNS-1011 Message to display, enable, or disable the iSNS Client service. INFO ISNS-1013 Message , [ISNS-1013 IP address. WARNING 36-4 Fabric OS Message Reference Publication Number - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 337
created. If a core file is found, FTP all core files to a secure server location. Copy the warning message, any core file information, and contact your switch service provider. WARNING Fabric OS Message Reference Publication Number: 53-1000242-01 37-1 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 338
37 KSWD-1003 37-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 339
KTRC System Messages Chapter 38 KTRC-1001 Message , [KTRC-1001], ,, WARNING, , Dump memory size exceeds dump file size Probable Indicates that the dump memory size has exceeded the dump file size. Cause Recommended No action is required. Action Severity - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 340
38 KTRC-1004 Probable Cause Recommended Action Severity Indicates that the ATA dump driver is not initialized properly. No action is required. ERROR KTRC-1004 Message , [KTRC-1004], ,, ERROR, , Cannot write to ATA dump device Probable Cause Recommended - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 341
on bladed switches. Run the saveCore command to FTP core files to a server location. It is normal behavior if there are no core files to transfer. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 342
on bladed switches. Run the saveCore command to FTP core files to a server location. It is normal behavior if there are no core files to transfer. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 343
valid link state ID is the same as the valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended No action is required. Action Severity ERROR LSDB-1002 Message , [LSDB-1002], ,, INFO, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 344
Probable Cause Recommended Action Severity Indicates that there is no local link state record entry in the link state database. The switch should always generate its own local entry when starting up. An "incarnation" is a progressive number that identifies the most recent version of - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 345
up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR MFIC-1002 Message , [MFIC-1002], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 346
state> Probable Cause Recommended Action Severity Indicates that one or more switches joined the fabric with a different insistent domain ID (IDID) mode or "Off". IDID mode is a fabric-wide mode; make sure that any switches added to the fabric are configured with the same IDID mode as the fabric. - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 347
MPTH System Messages Chapter 42 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = Probable Indicates that a null parent was reported. MPATH uses a tree structure in which the parent is used to Cause connect to the root of the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 348
42 MPTH-1003 Recommended Action Severity No action is required. WARNING 42-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 349
• 7 - MSG_LINIT_IU • 8 - MSG_RSCN • 9 - MSG_IOCTL • 10 - MSG_ACCEPT • 11 - MSG_IU_FREE • 12 - MSG_US • 13 - MSG_EXT_RSCN • 14 - MSG_RDTS_START • 15 - MSG_RDTS_SENDEFP • 16 - MSG_RDTS_RESET Recommended No action is required. Action Severity ERROR Fabric OS Message Reference Publication Number: 53 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 350
43 MQ-1004 43-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 351
. Recommended Action: Set the flag for the MS Platform Service. • The GCAP (MS Get Capabilities) is not supported by another switch. Recommended Action: Upgrade the firmware level on the switch to a level that supports RCS. • The request to the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 352
. • Set the flag for the MS Platform Service. • Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater. • - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 353
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. INFO MS-1005 Message , [MS-1005], ,, ERROR, , MS Invalid CT Response from d= Probable - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 354
phase of a reboot. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR MS-1022 Message , [MS-1022], ,, INFO, , Management Server Platform - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 355
Probable Cause Recommended Action Severity Indicates that Management Server Topology Discovery Service is being enabled or disabled. No action is required. INFO MS-1024 Message , [MS-1024], ,, INFO, , Management Server Access Control - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 356
44 MS-1024 44-6 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 357
finite state machine (NBFSM) states are as follows: • 0 - Down • 1 - Init • 2 - Database Exchange • 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full Recommended No action is required. Action Severity INFO NBFS-1002 Message , [NBFS-1002], , FFDC, ERROR - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 358
If this error occurs repeatedly, it means the protocol implementation between two connected switches has problems. Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is FULL, then this message can safely be ignored. Otherwise, run the portDisable and - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 359
payload exceeds the maximum frame size that the remote switch can handle. Run the firmwareDownload command to upgrade the remote switch with firmware v4.3 or higher, or v3.2 or higher, as appropriate for the switch type, so that it can support GMI to handle frame fragmentation and reassembly. You - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 360
>, can't send update. Probable Cause Recommended Action Severity Indicates that the name server on the standby CP has lower supported capability than the active CP due to different firmware versions running on the active and standby CPs. This means that the active and standby CPs are out of sync - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 361
during the installation. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1002 Message , [PDM-1002 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 362
the PDM process. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1004 Message , [PDM-1004], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 363
many entries. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1007 Message , [PDM-1007], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 364
setCfg failed. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1010 Message , [PDM-1010], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 365
conf is empty. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1014 Message , [PDM-1014], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 366
call failed. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. CRITICAL PDM-1019 Message , [PDM-1019], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 367
call failed. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING Fabric OS Message Reference Publication Number: 53 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 368
47 PDM-1021 47-8 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 369
Chapter 48 PDTR-1001 Message , [PDTR-1001], ,, INFO, , < informational message > Probable Cause Recommended Action Severity Indicates that information has been written to the panic dump files. The watchdog register codes are as follows: • 0x10000000 bit - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 370
48 PDTR-1002 48-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 371
a command-line prompt. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. CRITICAL PLAT-1001 Message , [PLAT-1001], ,, INFO, , Resetting standby CP (double reset may occur - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 372
49 PLAT-1001 49-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 373
specified port is now disabled because the link on this port had multiple failures that exceed an internally set threshold on the port. This problem is typically related to hardware. Check and replace (if necessary) the hardware attached to both ends of the specified port number, including: • the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 374
PORT-1005 Message , [PORT-1005], ,, WARNING, , Slot port does not support configured L_port. Issue portCfgLport to clear configuration. Probable Cause Recommended Action Severity Indicates that the specified port is configured - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 375
over) automatically. If it does not, reboot or power cycle the switch to reinitiate the firmware. CRITICAL PS-1001 Message , [PS-1001 changed. No action is required. Refer to the Fabric OS Administrator's Guide for more information about the PID format. INFO PS-1002 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 376
configuration has attempted to add end-to-end monitors on at least one ISL port. No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is enabled. ISL monitoring can only be disabled through the Fabric Access API. WARNING PS-1005 Message , [PS - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 377
PS-1005 51 Recommended Action Severity To resume counting, delete some end-to-end monitors sharing the same hardware resource pool. WARNING Fabric OS Message Reference Publication Number: 53-1000242-01 51-3 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 378
51 PS-1005 51-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 379
timestamp>, [PSWP-1002], ,, INFO, , Port Swap feature enabled Probable Indicates that the portSwap feature has been enabled in the switch. Cause Recommended No action is required. Action Severity INFO Fabric OS Message Reference Publication Number: 53-1000242-01 52-1 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 380
-1003], ,, INFO, , Port Swap feature disabled Probable Cause Recommended Action Severity Indicates that the portSwap feature has been disabled in the switch. No action is required. INFO 52-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 381
was captured. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. INFO RAS-1002 Message , [RAS-1002], ,, WARNING, , First failure data capture (FFDC) maximum storage size - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 382
error detected. Probable Cause Recommended Action Severity Indicates a internal software error. Run the supportSave command and contact your switch service provider. WARNING RAS-1005 Message , [RAS-1005], , FFDC, WARNING, , Software 'assert' error detected - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 383
in Fabric OS v2.6, v3.1 and greater, v4.1 and greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. INFO RCS-1002 Message , [RCS-1002], ,, INFO, , RCS has been enabled. Probable Cause Recommended - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 384
command. Check memory usage on the switch using the memShow command. Reboot or power cycle the switch. ERROR RCS-1004 Message , and greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 385
remote domain rejected an RCS phase initiated by an application on the local switch. If the reject phase is ACA, the remote domain might be busy and might not be compatible or the domain does not have the license to support that application. If the reject is in ACA phase, wait several minutes and - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 386
54 RCS-1008 RCS-1008 Message , [RCS-1008], ,, ERROR, , Domain Lowest Max Zone DB size Probable Cause Recommended Action Severity Indicates that the specified domain has the lowest maximum Zone database size. Reduce the zone database size. - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 387
Severity Indicates that an authentication error was reported. The specified client IP address has faulty credentials. Enter the correct user name and enable RPCD in Secure mode, install a valid SSL certificate on the switch. WARNING RPCD-1003 Message , [RPCD-1003], ,, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 388
, , Permission denied accessing private key file. Secure RPCd is disabled. Probable Indicates that the private key file configured on the switch could not be accessed because root did not Cause have read-level access. 55-2 Fabric OS Message Reference Publication Number: 53-1000242 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 389
RPCD-1007 55 Recommended Action Severity Change the file system access level for the private key file and make sure that root has read-level access. WARNING RPCD-1007 Message , [RPCD-1007], ,, WARNING, , Invalid private file. Secure RPCd is disabled. - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 390
55 RPCD-1007 55-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 391
• detail2: Domain • detail3: Retry Count • detail4: Status • detail5: Process ID Run the fabricShow command to see if the specified domain ID is online. Enable the switch with the specified domain ID. Fabric OS Message Reference Publication Number: 53-1000242-01 56-1 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 392
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING RTWR-1003 Message , [RTWR-1003], ,, INFO, , : RTWR retry - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 393
to a specific queue has failed because the SCN queue for the specified daemon name is full. This might be caused by the daemon hanging or if the system is busy. The supportSave command and contact your switch service provider. CRITICAL Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 394
57 SCN-1001 57-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 395
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR SEC-1002 Message , [SEC-1002], ,, ERROR, , Security data fails: Probable Cause - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 396
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING SEC-1005 Message , [SEC-1005], ,, INFO, , Primary FCS receives data request from domain - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 397
FTP transfers; then run the supportSave command and contact your switch service provider. WARNING SEC-1007 Message , [SEC-1007], IP address tries to establish TELNET connection. Probable Indicates that a security violation was reported. The IP - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 398
reported. The IP address of the unauthorized host is displayed in the message. Check for unauthorized access to the switch through the Fabric OS Administrator's Guide. If a certificate does not exist or is invalid, install the certificate by following the field upgrade process. WARNING SEC-1024 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 399
address () detected. Probable Cause Recommended Action Severity Indicates that a corruption occurred during the distribution of the security database. This can occur only when the primary FCS distributes the security database to the other switches in the fabric, then local validation - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 400
the error state, the database might not be correctly updated for that specific switch. ERROR SEC-1031 Message , [SEC-1031], ,, WARNING, , Current security policy DB cannot be supported by standby. CPs will go out of sync. 58-6 Fabric OS Message Reference - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 401
Cause Recommended Action Severity Indicates that the member parameter in the secPolicyAdd command is invalid (such as the asterisk symbol). Only valid switch identifiers, that is WWN, domain ID or switch name are supported for the member parameter. The asterisk symbol can be used to add all - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 402
58 SEC-1034 SEC-1034 Message , [SEC-1034], ,, ERROR, , Invalid member . Probable Cause Recommended Action Severity Indicates that the input list has an invalid member. Verify the member names, and input the correct information. ERROR SEC- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 403
Action Severity Indicates that the WWN entered in the policy member list had an invalid format. Run the command again using the standard WWN format, 16 hexadecimal digits grouped as eight colon separated pairs. For example: 50:06:04:81:D6:F3:45:42. ERROR SEC-1038 Message , [SEC-1038 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 404
58 SEC-1041 SEC-1041 Message , [SEC-1041], ,, ERROR, , Invalid port member in portlist (). . Probable Cause Indicates that the port member is invalid for one of the following reasons: • The value is not a number. • The - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 405
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 406
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 407
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 408
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 409
occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in either that no domains or domains more than the maximum number supported are specified. Cause Recommended Enter the correct number of domains. - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 410
Recommended Action Severity Indicates that the PKI objects on the switch are not in a valid state and the signature operation objects and install the certificate by following the field upgrade process. ERROR SEC-1065 Message , [SEC- -16 Fabric OS Message Reference Publication Number: 53 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 411
for unknown reasons. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR SEC-1073 Message , [SEC-1073], ,, ERROR, , No FCS policy in list! Probable Indicates that - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 412
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 413
SEC-1077 58 SEC-1077 Message , [SEC-1077], ,, ERROR, , Failed to activate new policy set on all switches. Probable Cause Recommended Action Severity Indicates that the policy could not be activated. Possible reasons that the policy could not be activate - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 414
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 415
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 416
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 417
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 418
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 419
only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in run the supportSave command and contact your switch service provider. ERROR Fabric OS Message Reference Publication Number: 53-1000242-01 58 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 420
automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR SEC-1099 Message , [SEC-1099], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 421
public key. Verify that the primary switch has a valid certificate installed and retry the operation. If a valid certificate is not installed, install a certificate by following the procedure specified in the Secure Fabric OS Administrator's Guide. ERROR Fabric OS Message Reference Publication - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 422
for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide. Severity ERROR SEC-1107 Message , [SEC-1107], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 423
security event was planned. If the security event was planned, run the secFabricShow command to verify that all switches in the fabric are in the ready state. When all switches are in the ready state, retry the operation. ERROR SEC-1110 Message , [SEC-1110], ,, ERROR - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 424
-name>, FCS list must be the first entry in the Active Security policies, and the same as the current active FCS list in the switch. Probable Cause Recommended Action Severity Indicates that either a security policy download is attempted with an active policy that does not have the FCS policy - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 425
. When all switches are in the ready state, retry the operation. INFO SEC-1118 Message , [SEC-1118], ,, INFO, , Fail to set SNMP string. Probable Cause Recommended Action Severity Indicates that the SNMP string could not be set. Usually this problem is - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 426
name>, Error code: , . Probable Indicates that one of the switches in the fabric could not communicate with the primary FCS. Cause Recommended Run the secFabricShow is required. Action Severity INFO 58-32 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 427
INFO SEC-1130 Message , [SEC-1130], ,, INFO, , The Primary FCS has failed over to a new switch. Probable Cause Recommended Action Severity Indicates that an FCS failover operation was completed successfully. Verify that the security event was planned. If - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 428
the security database sending from the primary FCS switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service, or the signature verification failed. Signature verification failure - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 429
the security database sending from the primary FCS switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service, or the signature verification failed. Signature verification failure - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 430
Probable Cause Recommended Action Severity Indicates that the PID format of the switch was changed either to extended-edge PID or from extendededge PID. If DCC polices existed, all index/area ID values either increased or decreased by 16. The values wrap around after 128. If a DCC policy contains an - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 431
support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 432
the failed command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. INFO SEC-1158 Message , [SEC-1158], ,, INFO, , Invalid name - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 433
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 434
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 435
. Verify that the security event was planned. If the security event was planned, retry FCS failover after current failover has completed, if this switch should become primary FCS. If the security event was not planned, take appropriate action as defined by your enterprise security policy. ERROR SEC - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 436
all PKI objects exist. If they do not exit, run the pkiCreate command to create them for the switch. Run the licenseAdd command to install the required license key. Refer to your switch supplier to obtain a license if you do not have one. ERROR SEC-1172 Message , [SEC-1172], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 437
name>, Failed to install zone data. Probable Cause Recommended Action Severity Indicates that the zone database could not be installed on the switch. Verify that all switches in the fabric are in time synchronization with the primary and that no external entity is trying to access the fabric. When - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 438
58 SEC-1180 SEC-1180 Message , [SEC-1180], ,, INFO, , Added account with authorization. Probable Cause Recommended Action Severity Indicates that the specified new account has been created. No action is required. INFO SEC-1181 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 439
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR SEC-1184 Message , [SEC-1184], ,, INFO, , Radius configuration change, action , server - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 440
-number>,, INFO, , Security violation: Unauthorized device tries to FLOGI to index/area of switch . Probable Cause Recommended Action Indicates that a DCC security violation was reported. The specified device attempted to login using FLOGI - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 441
1189 58 Severity INFO SEC-1189 Message , [SEC-1189], ,, INFO, , Security violation: Unauthorized host with IP address tries to do SNMP write operation. Probable Cause Recommended Action Severity Indicates that an SNMP security violation was - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 442
IP address IP Addr: - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 443
account names. Probable Cause Recommended Action Severity Indicates that the default switch accounts admin and user do not exist on the switch when enabling security. Reset the default admin and user account names on the switch that reported the warning and retry enabling security. WARNING SEC - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 444
to establish an API connection. Check to see if the host IP address specified in the message can be used to manage the fabric through an was reported. An attempt was made to access the serial console on the specified switch instance when it is disabled. Check to see if an authorized access attempt - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 445
Cause Recommended Action Severity Indicates that an MS operation security violation was reported. An MS device operation occurred on a non-primary FCS switch. Check the management server policy and verify that the connection is allowed. If the connection is allowed but not specified, enable the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 446
successful via TELNET/SSH/RSH. IP Addr: Probable Cause Recommended Action Severity Indicates the IP address of the remote station logging FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING SEC-1251 Message , [SEC- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 447
then run the supportSave command and contact your switch service provider. ERROR SEC-1300 Message , [SEC-1300], ,, INFO, , This switch is in VcEncode mode. Security is not supported. Probable Indicates that the switch is set up with VC-encoded mode. Cause - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 448
Secure Fabric OS feature. Run the firmwareDownload command to update the firmware to the latest version for your specific switch. Verify that the firmware you are installing supports the Brocade Secure Fabric OS feature. INFO SEC-1304 Message , [SEC-1304], ,, INFO - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 449
PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide. If PKI objects are valid, verify that an unauthorized switch is not trying to access the fabric. INFO SEC-1307 Message , [SEC-1307], ,, INFO, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 450
, Unable to determine data distribution limit of fabric. Please retry later. Probable Unable to obtain the data distribution limit from all switches in the fabric. This may happen if the fabric Cause is reconfiguring or a new domain joined the fabric. Recommended Retry the command when - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 451
Cause Recommended Action Severity Indicates that the security enable failed on the fabric because one or more switches in the fabric have password policies that are not set to the default value. Verify that the security event was planned. If the security event was planned, run the passwdCfg - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 452
Recommended Action Severity Indicates that the call to the EM module to retrieve the IP address failed. Please reboot the system to fix this error. If the problem persists contact your switch service provider. ERROR SEC-1315 Message , [SEC-1315], ,, ERROR, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 453
SEC-1317 58 SEC-1317 Message , [SEC-1317], ,, INFO, , Inconsistent fabric, rejecting transaction Probable Cause Recommended Action Severity Indicates that either this domain is performing an FDD merge or matched domains are not the same as what the CM - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 454
Severity Indicates that the security enable failed on the fabric because switch has conflicting configuration such as fabric wide consistency configuration or fabric is not able to support a DCC policy with more than 256 ports. Reconfigure any policy that has more than 256 ports in member list, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 455
by your enterprise security policy. INFO SEC-1325 Message , [SEC-1325], ,, ERROR, , Security enforcement: Switch connecting to port is not authorized to stay in fabric. Probable Cause Recommended Action Severity Indicates that - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 456
58 SEC-1326 SEC-1326 Message , [SEC-1326], ,, INFO, , Event: fddcfg --fabwideset, Status: success, Info: Fabric wide configuration set to . Probable Cause Recommended Action Severity Indicates that the specified - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 457
SNMP service could not be started because of the specified Reason. You will not be able to query the switch through SNMP. Verify that the IP address for of the SNMP service failed and you will not be able to query the switch through SNMP. Reboot or power cycle the switch. This will automatically - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 458
Action Severity Retry changing the SNMP community strings from the primary switch. ERROR SNMP-1004 Message , [SNMP-1004], < configuration is incorrect and the SNMP service will not work correctly. Change the SNMP configuration back to the default. ERROR SNMP-1005 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 459
Severity INFO SNMP-1006 59 Fabric OS Message Reference Publication Number: 53-1000242-01 59-3 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 460
59 SNMP-1006 59-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 461
has ftp'ed support information to the host with IP address . Probable Indicates that the supportSave command was used to transfer support information to a command to set the FTP parameters. After the FTP problem is corrected, rerun the supportSave command. WARNING Fabric OS Message Reference - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 462
60 SS-1001 60-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 463
, Forced failover succeeded. New Active CP is running new firmware. Probable Cause Recommended Action Severity Indicates that the previous standby has now become the active CP and is running the new firmware version. No action is required. The firmwareDownload command is - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 464
. Refer to the Fabric OS Administrator's Guide for troubleshooting information. INFO SULB-1022 Message , [SULB-1022], ,, WARNING, , The blade in slot has rebooted successfully with new firmware. 61-2 Fabric OS Message Reference Publication - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 465
downloaded to the specified AP blade and the AP blade will reboot to active it. Wait for the AP blade to reboot. WARNING SULB-1031 Message , [SULB-1031], ,, WARNING, , The switch is relocating an internal firmware image. Probable Cause Recommended Action - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 466
error can be caused by inconsistent AP blade firmware. It can also be caused by persistent storage hardware failure, or other hardware failures. Try reseating the AP blade. Run firmwareDownload again. If the problem persists, contact your switch service provider. ERROR SULB-1036 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 467
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR SWCH-1002 Message , [SWCH-1002], ,, INFO, , Security violation: Unauthorized device - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 468
slotPowerOn commands. On a SilkWorm 200E, 3250, 3850, 3900, or 4100 switch, reboot or power cycle the switch. ERROR SWCH-1004 Message , [SWCH-1004], ,, ERROR, , Blade attach failed during recovery, disabling slot = Probable Cause Recommended - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 469
support NPIV functionality and the switch has some NPIV devices logged into the fabric. Load a firmware version on standby that supports to the Fabric OS Administrator's Guide for more information about buffers. support port swap. Slot will be faulted. Probable Indicates that the blade - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 470
62 SWCH-1008 Recommended Action Severity Replace the blade with ports that support port swap. Then port swap the ports back to ports default area. Refer to the Fabric OS Administrator's Guide for more information on port swapping. WARNING 62-4 Fabric OS Message Reference Publication Number: 53- - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 471
for one or more programs to register with system services or to fail over to active status. The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before rebooting the chassis, record the firmware version on the switch (or CP) and run the haDump command. If this - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 472
chassis option storage device> is not supported by CP Blade with ID - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 473
SYSC-1005 63 Recommended Action Severity Use the supportSave command to gather troubleshooting data. Issue a hardboot or hafailover to recover the system and limit the traffic disruption. WARNING Fabric OS Message Reference Publication Number: 53-1000242-01 63-3 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 474
63 SYSC-1005 63-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 475
memory. Run the memShow command to view the switch memory usage. Reboot or power cycle the switch. Run supportFtp and traceFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. CRITICAL SYSM-1002 Message , [SYSM - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 476
64 SYSM-1003 SYSM-1003 Message , [SYSM-1003], ,, INFO, , , Switch: Probable Cause Recommended Action Severity Indicates that the user executed the switchStart or switchReboot command. This indicates that all services CP blade in - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 477
SYSM-1006 64 SYSM-1006 Message , [SYSM-1006], , FFDC, CRITICAL, , CP blade in slot is incompatible with the chassis type. Probable Cause Recommended Action Severity Indicates that this chassis type is not compatible with the CP blade. Use - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 478
64 SYSM-1007 64-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 479
• WATCHDOG EXPIRED generated by hardware watchdog expiration • MANUAL generated by the tracedump -n command Run supportFtp and traceFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING TRCE-1002 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 480
down, or the network being down. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Note: You can also run the traceFtp -e command to enable auto-FTP. ERROR 65-2 Fabric OS Message Reference Publication Number: 53 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 481
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR TRCE-1008 Message , [TRCE-1008], , FFDC, CRITICAL, , Unable to load trace parameters. Probable - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 482
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR TRCE-1011 Message , [TRCE-1011], ,, INFO, , Trace dump manually transferred to target ' - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 483
the indicated slot is unavailable. Cause Recommended Check that the AP blade is enabled and retry the command. If the AP blade is already enabled, run the Action supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference Publication Number: 53-1000242 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 484
65 TRCE-1012 65-6 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 485
by an authorized user. If this message occurs repeatedly, it might indicate an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the IP address of a failed login is reported to the error log. INFO TRCK-1003 Message , [TRCK-1003], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 486
change from task: Probable Cause Recommended Action Severity Indicates that the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configDownload. This message is not - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 487
TRCK-1006 66 Recommended Action Severity No action is required. Run the trackChangesSet 1 command to enable the track changes feature. INFO Fabric OS Message Reference Publication Number: 53-1000242-01 66-3 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 488
66 TRCK-1006 66-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 489
FCS switch is used for fabric synchronization. This might be logged during temporary operational issues such as IP network IP network connection issues to the external clock server or if the fabric is configured for external time synchronization but the principal or primary FCS does not support - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 490
switch has the clock server IP configured correctly. Verify that this clock server is accessible to the switch and functional. If the principal or primary FCS does not support the feature, either choose a different switch : • Init failed. Time Service exiting Probable Cause: Initialization error - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 491
-name>, Inconsistent route detected: Port = , should be Probable Cause Recommended Action Severity Indicates that the switch detected an inconsistency in the routing database between the routing protocol and the hardware configuration. The first port number displayed is - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 492
68 UCST-1020 UCST-1020 Message , [UCST-1020], ,, WARNING, , Static route (input-area: , domain: output-area: ) has been ignored due to platform limitation. Probable Cause Recommended Action Severity Indicates that the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 493
-1001 Message , [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list Probable Indicates that the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists Cause in the candidate list (domain ID list). Recommended No action - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 494
69 UPTH-1001 69-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 495
USWD System Messages Chapter 70 USWD-1006 Message , [USWD-1006], ,, WARNING, , uSWD: Probable Indicates a warning state in the system. This is an internal use only message. Cause Recommended No action is required. Action Severity WARNING - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 496
70 USWD-1006 70-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 497
WEBD System Messages Chapter 71 WEBD-1001 Message , [WEBD-1001], ,, WARNING, , Missing or Invalid Certificate file -- HTTPS is configured to be enabled but could not be started. Probable Cause Recommended Action Severity Indicates that the SSL - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 498
71 WEBD-1004 Probable Cause Recommended Action Severity Indicates that the HTTP/HTTPS interface is disabled. This is logged when HTTP/HTTPS is disabled through the configure command. Run the configure command to enable HTTP/HTTPS. For more information on the configure command, refer to the Fabric - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 499
restarted due to change of IP Address Probable Cause Recommended Action Severity Indicates that the IP address of the switch changed and the HTTP server where the builtin recovery process has failed to restore http services. The problem often results from invalid configuration of ssl certs., but - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 500
71 WEBD-1008 71-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 501
the saveCore command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR Fabric OS Message Reference Publication Number: 53-1000242-01 72-1 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 502
72 ZOLB-1001 72-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 503
trap processing. This messages usually indicates problems when adding CAM entries before the filter setup. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING ZONE-1003 Message - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 504
zones are more secure than "sessionbased hard zones". Both types of zones will trap a PLOGI, but hard zones will filter out the I/O frames which"session-based" hard zones do not. If hard zone enforcement is preferred, edit the zoning database to have the port zoned with devices defined as either WWN - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 505
CAM entries before the filter setup. There are two ways to avoid this problem. • Avoid having too many hosts zoned with a set of target devices Avoid having too many zones directed at a single port group on the switch. INFO ZONE-1008 Message , [ZONE-1008], ,, WARNING - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 506
Probable Cause Recommended Action Severity Indicates that the QuickLoop feature is not supported in the current code release. If the QuickLoop zoning configuration is enabled on the switch, it will not be supported. Edit the zone database to remove the QuickLoop zoning definition in the effective - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 507
Action Severity Indicates that the required zoning license is missing. Install the zoning license using the licenseAdd command. Refer to your switch supplier to obtain a Zoning license if you do not have one. ERROR ZONE-1015 Message , [ZONE-1015], ,, WARNING - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 508
based hard zoning (value = 3) • FA zone (value = 5) QuickLoop zones are not supported in Fabric OS v4.x. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service indicates a transitory problem. Wait a few - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 509
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. INFO ZONE-1024 Message , [ZONE-1024], ,, INFO, , Probable Cause Recommended Action - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 510
User Command: A user aborted the current zoning transaction. • Switch Shutting Down: The switch is currently shutting down. Many of the causes of this error -1028], ,, WARNING, , Commit zone DB larger than supported - greater than 73-8 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 511
specific switches in your fabric. Refer to the Fabric OS Administrator's Guide for information on the zone database sizes supported for each switch. FTP transfers; then run the supportSave command and contact your switch service provider. WARNING ZONE-1030 Message , [ZONE-1030], - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 512
ZONE-1031 ZONE-1031 Message , [ZONE-1031], ,, ERROR, , Switch is in interop mode. (switch, port) members not supported. Probable Cause Recommended Action Severity The switch is set to interop mode using the interopMode command. Interop mode does not allow - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 513
zone database is not found. Use the firmwareDownload command to reinstall the firmware. WARNING ZONE-1035 Message , [ZONE-1035], ,, the zone configuration is too large for the memory available on the switch. Reduce the size of the zone database and retry the operation. - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 514
the Fabric OS cannot read the zone configuration file. Typically the zone configuration is Cause too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR 73-12 Fabric OS Message Reference Publication Number - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 515
Fabric OS cannot read the merged zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Reduce the size of the zone database and retry the operation. INFO ZONE-1041 Message , [ZONE-1041], ,, WARNING, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 516
Zone access mode is set to No Access Probable Cause Recommended Action Severity Indicates that the Default Zone access mode is set to No Access. Verify that this Default Zone access mode change was done intentionally. INFO ZONE-1044 Message , [ZONE-1044], ,, INFO - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 517
1046 73 ZONE-1046 Message , [ZONE-1046], ,, INFO, , The Default Zone access mode is already set to All Access Probable Cause Recommended Action Severity Indicates that the Default Zone access mode is already set to All Access. No action is required. INFO - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 518
73 ZONE-1046 73-16 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 519
Audit Log Messages This section provides the Audit messages, including: • AUDIT AUTH System Messages • AUDIT CONF System Messages • AUDIT HTTP System Messages • AUDIT SEC System Messages • AUDIT SNMP System Messages • AUDIT SULB System Messages • AUDIT ZONE System Messages Section II Fabric OS - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 520
II-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 521
AUDIT AUTH System Messages Chapter 74 AUTH-3001 Message AUDIT, , [AUTH-3001], INFO, SECURITY, , , , Event: , Status: success, Info: type has been changed from [] to []. Probable Cause Recommended - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 522
74 AUTH-3003 AUTH-3003 Message AUDIT, , [AUTH-3003], INFO, SECURITY, , , , Event: , Status: success, Info: the PKI objects. Probable Cause Recommended Action Severity Indicates that the pki Objects were created using - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 523
AUDIT CONF System Messages Chapter 75 CONF-1000 Message AUDIT, , [CONF-1000], INFO, CFG, , , , configDownload completed successfully . Probable Cause Recommended Action Severity The configDownload process was - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 524
-1022 Message AUDIT, , [CONF-1022], WARNING, CFG, , , , Downloading configuration without disabling the switch was unsuccessful. Probable Cause Recommended Action Severity The system attempted to download a configuration without disabling the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 525
AUDIT HTTP System Messages Chapter 76 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Recommended Action Severity Indicates - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 526
76 HTTP-1003 76-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 527
AUDIT SEC System Messages Chapter 77 SEC-3001 Message AUDIT, , [SEC-3001], INFO, SECURITY, , , , Event: , Status: success, Info: Security mode on the fabric. Probable Cause Recommended Action - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 528
77 SEC-3003 SEC-3003 Message AUDIT, , [SEC-3003], INFO, SECURITY, , , , Event: , Status: success, Info: Created policy, with member(s) . Probable Cause Recommended Action Severity Indicates that a new - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 529
SEC-3006 77 Recommended Action Severity Verify that the addition of members to the policy was planned. If the addition of members was planned, no action is required. If the addition of members was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3006 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 530
77 SEC-3008 SEC-3008 Message AUDIT, , [SEC-3008], INFO, SECURITY, , , , Event: , Status: success, Info: FCS member moved from position to . Probable Cause Recommended Action Severity Indicates - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 531
SEC-3011 77 Severity INFO SEC-3011 Message AUDIT, , [SEC-3011], INFO, SECURITY, , , , Event: , Status: success, Info: Reset [] statistics on domain(s) []. Probable Cause Recommended Action Severity Indicates - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 532
, , , , Event: , Status: success, Info: RADIUS server for AAA services. Probable Cause Recommended Action Severity Indicates that a user has changed the RADIUS configuration. Verify that the RADIUS configuration was - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 533
SEC-3017 77 Probable Cause Recommended Action Severity Indicates that a user has changed the specified attribute of the RADIUS server. Verify that the RADIUS attribute was intentionally changed. If the RADIUS attribute was intentionally changed, no action is required. If the RADIUS attribute was - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 534
parameters set to default values. Probable Cause Recommended Action Severity Indicates that the passwdCfg parameters are set to default values. Verify that failed, Info: Failed login attempt via . Probable Cause Recommended Action Severity Indicates that a failed - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 535
, the account has been locked. The Account may automatically unlock after the lockout duration has expired or an administrator may manually unlock the account. INFO SEC-3024 Message AUDIT, , [SEC-3024], INFO, SECURITY, , , , Event: - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 536
77 SEC-3025 SEC-3025 Message AUDIT, , [SEC-3025], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] added. Role: [], Password [], Home AD [], AD list [ - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 537
SEC-3028 77 Severity INFO SEC-3028 Message AUDIT, , [SEC-3028], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] deleted. Probable Cause Recommended Action Severity Indicates that the specified user - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 538
3032 Message AUDIT, , [SEC-3032], INFO, SECURITY, , , , Event: , Status: success, Info: Switch is configured to database. Probable Cause Recommended Action Severity Indicates that the specified event - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 539
SEC-3034 77 Recommended Action Severity Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3034 Message AUDIT, , [SEC-3034], INFO, SECURITY, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 540
77 SEC-3034 77-14 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 541
SNMP-1006 Message AUDIT, , [SNMP-1006], INFO, CONFIGURATION, , , , configuration was reset to default Probable Cause Recommended Action Severity Indicates that the SNMP configuration group was reset to the factory - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 542
78 SNMP-1006 78-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 543
to continue without disruption. Do not fail over or power down the system during firmware upgrade. Run the firmwareDownloadStatus command for more information. WARNING SULB that the firmwareDownload command has completed successfully and switch firmware has been updated. No action is required. - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 544
No action is required. Run the firmwareDownloadStatus command for more information. INFO SULB-1009 Message AUDIT, , [SULB-1009], INFO, FIRMWARE, , , , Firmwaredownload command failed. status: 0x, error: 0x. Probable Cause - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 545
due to Standby CP timeout." 0x57 "Standby CP failed to reboot and was not responding." 0x58 "Unable to check the firmware version on Standby CP due to IPC error." 0x59 "Sanity check failed because firmwareDownload is already in progress." 0x60 "Sanity check failed because firmwareDownload - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 546
on Standby CP." "Standby CP reboots." "Standby CP failed to reboot." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "There was an unexpected reboot during firmwareDownload. The command is aborted." "Standby CP was not responding. The command is aborted - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 547
0xa5 "New firmware failed to boot up. Please retry firmwareDownload." 0xa6 "firmwareCommit has started on the blade. This may take up to 10 minutes." 0xa7 "firmwareRestore is entered. System will reboot and a firmwareCommit 0xa8 operation will start upon boot up." "Switch is relocating the - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 548
. No need to download the same version of firmware." "Upgrade is inconsistent. Run bootenv command to change it switch is supported by the requested firmware. Also check firmwaredownload help page for other possible failure reasons." "The RPM package database is inconsistent. Contact your service - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 549
Device Based Routing policy is not supported by 5.1. 0x2d Use aptPolicy to change the routing policy before proceeding." "Invalid RPM package. Please reload firmware packages on the file server." 0x2e "Cannot downgrade due to presence of blade type 17. Remove or power off these 0x2f blades before - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 550
the chassis. Remove or power off the unsupported blades before proceeding. This can also be caused by an invalid chassisConfig option setting. In that case, reset the chassisConfig option before retrying firmwareDownload. 0x2e - Invalid RPM package. Please reload firmware packages on the file server - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 551
upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting blade. The error can be caused by inconsistent AP blade firmware stored - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 552
to remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. ERROR SULB-1020 Message AUDIT, , [SULB-1020], ERROR, FIRMWARE, , , , New firmware failed to boot in slot - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 553
example, powering off and on of the indicated BP blade in the problem persists, contact the service provider for further actions. WARNING SULB-1024 Message AUDIT, , [SULB-1024], WARNING, FIRMWARE, , , , Firmware commit has completed on the blade - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 554
after the switch is rebooted. So continue to run the firmwareDownloadStatus command to monitor the progress. However, if this problem persists, contact the service provider for further actions. WARNING SULB-1034 Message AUDIT, , [SULB-1034], ERROR, FIRMWARE, - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 555
command, for example, power the switch on an off in the middle of a firmwareDownload. This error can also be caused by the persistent storage failure, or other hardware failures. Recommended Retry the firmwareDownload operation. If the problem persists, contact your switch service provider. Action - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 556
79 SULB-1034 79-14 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 557
AUDIT ZONE System Messages Chapter 80 ZONE-3001 Message AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \" - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 558
80 ZONE-3003 ZONE-3003 Message AUDIT, , [ZONE-3003], INFO, ZONE, , , , Event: , Status: success, Info: \"\" deleted. Probable Cause Recommended Action Severity Indicates that the specified zone - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 559
ZONE-3006 80 Recommended Action Severity Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO ZONE-3006 Message AUDIT, , [ZONE-3006], INFO, ZONE, < - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 560
80 ZONE-3009 Recommended Action Severity Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO ZONE-3009 Message AUDIT, , [ZONE-3009], INFO, ZONE, < - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 561
ZONE-3012 80 Recommended Action Severity Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO ZONE-3012 Message AUDIT, , [ZONE-3012], INFO, ZONE, < - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 562
80 ZONE-3015 Probable Cause Recommended Action Severity Indicates that the specified new AD object member or members have been added to the specified AD object set. An AD object set type is "AD member". The string "..." appears at the end of the AD object member list if the list was truncated in - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 563
ZONE-3017 80 ZONE-3017 Message AUDIT, , [ZONE-3017], INFO, FABRIC, , , , Event: , Status: success, Info: \"\" created with \"\". Probable Cause Recommended Action - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 564
80 ZONE-3020 Severity INFO ZONE-3020 Message AUDIT, , [ZONE-3020], INFO, FABRIC, , , , Event: , Status: success, Info: \"\" removed from \"\". Probable Cause Recommended - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 565
ZONE-3023 80 Severity INFO ZONE-3023 Message AUDIT, , [ZONE-3023], INFO, FABRIC, , , , Event: , Status: Failure, Info: AD Apply operation failed due to transaction conflict. Probable Cause Recommended Action Severity Indicates that - HP StorageWorks 2/128 | Brocade Fabric OS Message Reference Guide (53-1000242-01 - Page 566
80 ZONE-3025 80-10 Fabric OS Message Reference Publication Number: 53-1000242-01
Publication Number: 53-1000242-01
Publication Date:
09/29/06
Fabric OS
Message Reference
Supporting Fabric OS v5.2.0