HP StorageWorks 2/32 Brocade Fabric OS Message Reference Guide (53-1000242-01,
HP StorageWorks 2/32 - SAN Switch Manual
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/32 manual content summary:
- HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 1
Fabric OS Message Reference Supporting Fabric OS v5.2.0 Publication Number: 53-1000242-01 Publication Date: 09/29/06 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 2
license agreements. To find-out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd. Export of technical data contained in this - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 3
the Brocade Fabric Manual Fabric OS System Error Message Reference Manual Fabric OS System Error Message Reference Manual Fabric OS System Error Message Reference Manual Fabric OS System Error Message Reference Manual 2003 53-0000515-08 Update software and hardware support March 2004 53-0000515-09 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 4
- HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 5
About This Document How This Document Is Organized Supported Hardware and Software What's New in This Document Document Conventions Message Log 1-1 System Logging Daemon (syslogd 1-2 System Console 1-3 Port Logs 1-3 Viewing and Configuring System Message Logs 1-4 Viewing System Messages - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 6
Responding to a System Message 1-12 Looking Up a System Message 1-12 Gathering Information About the Problem 1-13 Support 1-13 Panic Dump and Core Dump Files 1-14 Trace Dumps 1-14 supportSave Command 1-14 System Module Descriptions 1-15 Section I RASLog Messages Chapter 2 AUTH System - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 7
Chapter 3 AUTH-1028 2-8 AUTH-1029 2-9 AUTH-1030 2-9 AUTH-1031 2-10 AUTH-1032 2-10 AUTH-1033 2-11 AUTH-1034 2-11 AUTH-1035 2-11 AUTH-1036 2-12 AUTH-1037 2-12 AUTH-1038 2-13 BL System Messages BL-1000 2-1 BL-1001 2-1 BL-1002 2-1 BL-1003 2-2 BL-1004 2-2 BL-1006 2-3 BL-1007 2-3 BL- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 8
Chapter 4 Chapter 5 BL-1020 2-8 BL-1021 2-9 BL-1022 2-9 BL-1023 2-9 BL-1024 2-10 BL-1025 2-10 BL-1026 2-10 BL-1027 2-11 BL-1028 2-11 BL-1029 2-11 BL-1030 2-12 BL-1031 2-12 BL-1032 2-12 BL-1033 2-13 BL-1034 2-13 BL-1035 2-14 BLL System Messages BLL-1000 2-1 BM System Messages BM- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 9
Chapter 6 Chapter 7 Chapter 8 Chapter 9 BM-1056 2-5 BM-1058 2-5 CDR System Messages CDR-1001 2-1 CDR-1002 2-1 CER System Messages CER-1001 2-1 CONF System Messages CONF-1000 2-1 CONF-1001 2-1 CONF-1020 2-2 CONF-1021 2-2 CONF-1022 2-2 EM System Messages EM-1001 2-1 EM-1002 2-1 EM-1003 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 10
-1047 2-13 EM-1048 2-13 EM-1049 2-14 EM-1050 2-14 EM-1051 2-14 EM-1055 2-15 EM-1056 2-15 EM-1057 2-15 EM-1058 2-16 EM-1059 2-16 EM-1060 2-16 EM-1061 2-17 x Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 11
EM-1062 2-17 EM-1063 2-17 EM-2003 2-18 Chapter 10 EVMD System Messages EVMD-1001 2-1 Chapter 11 FABR System Messages FABR-1001 2-1 FABR-1002 2-1 FABR-1003 2-2 FABR-1004 2-2 FABR-1005 2-3 FABR-1006 2-3 FABR-1007 2-3 FABR-1008 2-4 FABR-1009 2-4 FABR-1010 2-4 FABR-1011 2-5 FABR-1012 2-5 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 12
-1014 2-5 FABS-1015 2-5 Chapter 13 FBC System Messages FBC-1001 2-1 Chapter 14 FCIP System Messages FCIP-1000 2-1 Chapter 15 FCMC System Messages FCMC-1001 2-1 Chapter 16 FCPD System Messages FCPD-1001 2-1 FCPD-1002 2-1 xii Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 13
FCPD-1003 2-2 Chapter 17 FCPH System Messages FCPH-1001 2-1 Chapter 18 FCR System Messages FCR-1001 2-1 FCR-1002 2-1 FCR-1003 2-1 FCR-1004 2-2 FCR-1005 2-2 FCR-1006 2-2 FCR-1007 2-3 FCR-1008 2-3 FCR-1009 2-3 FCR-1010 2-4 FCR-1011 2-4 FCR-1012 2-4 FCR-1013 2-5 FCR-1015 2-5 FCR-1016 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 14
FCR-1040 2-13 FCR-1041 2-14 FCR-1042 2-14 FCR-1043 2-14 FCR-1048 2-15 FCR-1049 2-15 FCR-1053 2-15 FCR-1054 2-16 FCR-1055 2-16 FCR-1056 2-16 FCR-1057 2-17 FCR-1058 2-17 FCR-1059 2-17 FCR-1060 2-18 FCR-1061 2-18 FCR-1062 2-19 FCR-1063 2-19 FCR-1064 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 15
FCR-1067 2-20 FCR-1068 2-21 FCR-1069 2-21 FCR-1070 2-21 FCR-1071 2-22 FCR-1072 2-22 FCR-1073 2-22 Chapter 19 FICU System Messages FICU-1001 2-1 FICU-1002 2-1 FICU-1003 2-2 FICU-1004 2-2 FICU-1005 2-3 FICU-1006 2-3 FICU-1007 2-3 FICU-1008 2-4 FICU-1009 2-4 FICU-1010 2-4 Chapter 20 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 16
FSPF-1002 2-1 FSPF-1003 2-1 FSPF-1005 2-2 FSPF-1006 2-2 Chapter 23 FSS System Messages FSS-1001 2-1 FSS-1002 2-1 FSS-1003 2-2 FSS-1004 2-2 FSS-1005 2-2 FSS-1006 2-3 FSS-1007 2-3 Chapter 24 FSSM System Messages FSSM-1002 2-1 FSSM-1003 2-1 FSSM-1004 2-2 Chapter 25 FW System Messages FW- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 17
-1114 2-12 FW-1115 2-13 FW-1116 2-13 FW-1117 2-13 FW-1118 2-14 FW-1119 2-14 FW-1120 2-15 FW-1121 2-15 FW-1122 2-16 FW-1123 2-16 Fabric OS Message Reference xvii Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 18
FW-1124 2-16 FW-1125 2-17 FW-1126 2-17 FW-1127 2-18 FW-1128 2-18 FW-1129 2-19 FW-1130 2-19 FW-1131 2-19 FW-1132 2-20 FW- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 19
FW-1178 2-29 FW-1179 2-30 FW-1180 2-30 FW-1181 2-30 FW-1182 2-31 FW-1183 2-31 FW-1184 2-31 FW-1185 2-32 FW-1186 2-32 FW-1187 2-32 FW-1188 2-33 FW-1189 2-33 FW-1190 2-33 FW-1191 2-34 FW-1192 2-34 FW-1193 2-34 FW-1194 2-35 FW-1195 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 20
2-45 FW-1301 2-45 FW-1302 2-45 FW-1303 2-46 FW-1304 2-46 FW-1305 2-47 FW-1306 2-47 FW-1307 2-47 FW-1308 2-48 FW-1309 2-48 FW-1310 2-49 FW-1311 2-49 FW-1312 2-49 FW-1313 2-50 FW-1314 2-50 FW-1315 2-50 xx Fabric OS Message Reference Publication - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 21
FW-1316 2-51 FW-1317 2-51 FW-1318 2-51 FW-1319 2-52 FW-1320 2-52 FW-1321 2-53 FW-1322 2-53 FW-1323 2-53 FW-1324 2-54 FW-1325 2-54 FW-1326 2-54 FW-1327 2-55 FW-1328 2-55 FW-1329 2-56 FW-1330 2-56 FW-1331 2-56 FW-1332 2-57 FW-1333 2-57 FW-1334 2-57 FW-1335 2-58 FW-1336 2-58 FW- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 22
FW-1347 2-63 FW-1348 2-63 FW-1349 2-63 FW-1350 2-64 FW-1351 2-64 FW-1352 2-65 FW-1353 2-65 FW-1354 2-66 FW-1355 2-66 FW-1356 2-66 FW-1357 2-67 FW-1358 2-67 FW-1359 2-68 FW- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 23
FW-1378 2-75 FW-1379 2-75 FW-1400 2-75 FW-1401 2-76 FW-1402 2-76 FW-1403 2-76 FW-1424 2-77 FW-1425 2-77 FW-1426 2-77 FW-1427 2-78 FW-1428 2-78 FW-1429 2-78 FW-1430 2-79 FW-1431 2-79 FW-1432 2-79 FW-1433 2-80 FW-1434 2-80 FW-1435 2-81 FW-1436 2-81 FW-1437 2-81 FW-1438 2-82 FW- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 24
Chapter 26 HAM System Messages HAM-1001 2-1 HAM-1002 2-1 HAM-1004 2-2 Chapter 27 HAMK System Messages HAMK-1001 2-1 HAMK-1002 2-1 HAMK-1003 2-2 HAMK-1004 2-2 Chapter 28 HIL System Messages HIL-1101 2-1 HIL-1102 2-1 HIL-1103 2-2 HIL-1104 2-2 HIL-1105 2-2 HIL-1106 2-3 HIL-1107 2-3 HIL- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 25
HIL-1503 2-13 HIL-1504 2-13 HIL-1505 2-14 HIL-1506 2-14 HIL-1507 2-14 HIL-1508 2-15 HIL-1509 2-15 HIL-1510 2-16 HIL-1601 2-16 HIL-1602 2-16 Chapter 29 HLO System Messages HLO-1001 2-1 HLO-1002 2-1 HLO-1003 2-2 Chapter 30 HMON System Messages HMON-1001 2-1 Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 26
Chapter 31 HTTP System Messages HTTP-1001 2-1 HTTP-1002 2-1 HTTP-1003 2-1 Chapter 32 IBPD System Messages IBPD-1001 2-1 IBPD-1002 2-1 IBPD-1003 2-2 Chapter 33 ICPD System Messages ICPD-1001 2-1 ICPD-1002 2-1 ICPD-1003 2-1 ICPD-1004 2-2 ICPD-1005 2-2 ICPD- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 27
Chapter 36 ISNS System Messages ISNS-1001 2-1 ISNS-1002 2-1 ISNS-1003 2-2 ISNS-1004 2-2 ISNS-1005 2-2 ISNS-1006 2-3 ISNS-1008 2-3 ISNS-1009 2-3 ISNS-1010 2-4 ISNS-1011 2-4 ISNS-1013 2-4 Chapter 37 KSWD System Messages KSWD-1003 2-1 Chapter 38 KTRC System Messages KTRC-1001 2-1 KTRC-1002 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 28
LSDB-1004 2-2 Chapter 41 MFIC System Messages MFIC-1001 2-1 MFIC-1002 2-1 MFIC-1003 2-2 Chapter 42 MPTH System Messages MPTH-1001 2-1 MPTH-1002 2-1 MPTH-1003 2-1 Chapter 43 MQ System Messages MQ-1004 2-1 Chapter 44 MS System Messages MS-1001 2-1 MS-1002 2-1 MS-1003 2-2 MS-1004 2-2 MS- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 29
-1009 2-3 PDM-1010 2-4 PDM-1011 2-4 PDM-1012 2-4 PDM-1013 2-5 PDM-1014 2-5 PDM-1017 2-5 PDM-1019 2-6 PDM-1020 2-6 PDM-1021 2-6 Chapter 48 PDTR System Messages PDTR-1001 2-1 PDTR-1002 2-1 Chapter 49 PLAT System Messages PLAT-1000 2-1 Fabric OS Message Reference xxix Publication Number - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 30
PLAT-1001 2-1 Chapter 50 PORT System Messages PORT-1003 2-1 PORT-1004 2-1 PORT-1005 2-2 Chapter 51 PS System Messages PS-1000 2-1 PS-1001 2-1 PS-1002 2-1 PS-1003 2-2 PS-1004 2-2 PS-1005 2-2 Chapter 52 PSWP System Messages PSWP-1001 2-1 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 31
RCS-1005 2-2 RCS-1006 2-3 RCS-1007 2-3 RCS-1008 2-4 Chapter 55 RPCD System Messages RPCD-1001 2-1 RPCD-1002 2-1 RPCD-1003 2-1 RPCD-1004 2-2 RPCD-1005 2-2 RPCD-1006 2-2 RPCD-1007 2-3 Chapter 56 RTWR System Messages RTWR-1001 2-1 RTWR-1002 2-1 RTWR-1003 2-2 Chapter 57 SCN System Messages - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 32
SEC-1022 3-4 SEC-1024 3-4 SEC-1025 3-5 SEC-1026 3-5 SEC-1028 3-5 SEC-1029 3-6 SEC-1030 3-6 SEC-1031 3-6 SEC-1032 3-7 SEC-1033 3-7 SEC-1034 3-8 SEC-1035 3-8 SEC-1036 3-8 SEC-1037 3-9 SEC-1038 3-9 SEC-1040 3-9 SEC-1041 3-10 SEC-1042 3-10 SEC-1043 3-10 SEC-1044 3-11 SEC-1045 3-11 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 33
SEC-1059 3-15 SEC-1062 3-15 SEC-1063 3-15 SEC-1064 3-16 SEC-1065 3-16 SEC-1069 3-16 SEC-1071 3-17 SEC-1072 3-17 SEC-1073 3-17 SEC-1074 3-18 SEC-1075 3-18 SEC-1076 3-18 SEC-1077 3-19 SEC-1078 3-19 SEC- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 34
SEC-1111 3-29 SEC-1112 3-30 SEC-1115 3-30 SEC-1116 3-30 SEC-1117 3-31 SEC-1118 3-31 SEC-1119 3-31 SEC-1121 3-32 SEC-1122 3-32 SEC-1123 3-32 SEC-1124 3-33 SEC-1126 3-33 SEC-1130 3-33 SEC-1135 3-34 SEC-1136 3-34 SEC-1137 3-34 SEC-1138 3-35 SEC-1139 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 35
SEC-1142 3-35 SEC-1145 3-36 SEC-1146 3-36 SEC-1153 3-37 SEC-1154 3-37 SEC-1155 3-37 SEC-1156 3-38 SEC-1157 3-38 SEC-1158 3-38 SEC-1159 3-39 SEC-1160 3-39 SEC-1163 3-39 SEC-1164 3-40 SEC-1165 3-40 SEC-1166 3-40 SEC-1167 3-41 SEC-1168 3-41 SEC-1170 3-41 SEC-1171 3-42 SEC-1172 3-42 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 36
SEC-1187 3-46 SEC-1188 3-46 SEC-1189 3-47 SEC-1190 3-47 SEC-1191 3-47 SEC-1192 3-48 SEC-1193 3-48 SEC-1194 3-48 SEC-1195 3-49 SEC-1196 3-49 SEC-1197 3-49 SEC-1198 3-50 SEC-1199 3-50 SEC-1200 3-50 SEC-1201 3-51 SEC-1202 3-51 SEC- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 37
SEC-1311 3-57 SEC-1312 3-57 SEC-1313 3-57 SEC-1314 3-58 SEC-1315 3-58 SEC-1316 3-58 SEC-1317 3-59 SEC-1318 3-59 SEC-1319 3-59 SEC-1320 3-60 SEC-1321 3-60 SEC-1322 3-60 SEC-1323 3-61 SEC-1324 3-61 SEC-1325 3-61 SEC-1326 3-62 SEC-1327 3-62 Chapter 59 SNMP System Messages SNMP-1001 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 38
SWCH-1006 3-3 SWCH-1007 3-3 SWCH-1008 3-3 Chapter 63 SYSC System Messages SYSC-1001 3-1 SYSC-1002 3-1 SYSC-1003 3-2 SYSC-1004 3-2 SYSC-1005 3-2 Chapter 64 SYSM System Messages SYSM-1001 3-1 SYSM-1002 3-1 SYSM-1003 3-2 xxxviii Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 39
SYSM-1004 3-2 SYSM-1005 3-2 SYSM-1006 3-3 SYSM-1007 3-3 Chapter 65 TRCE System Messages TRCE-1001 3-1 TRCE-1002 3-1 TRCE-1003 3-2 TRCE-1004 3-2 TRCE-1005 3-2 TRCE-1006 3-3 TRCE-1007 3-3 TRCE-1008 3-3 TRCE-1009 3-4 TRCE-1010 3-4 TRCE-1011 3-4 TRCE-1012 3-5 Chapter 66 TRCK System - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 40
Chapter 68 UCST System Messages UCST-1003 3-1 UCST-1007 3-1 UCST-1020 3-2 Chapter 69 UPTH System Messages UPTH-1001 3-1 Chapter 70 USWD System Messages USWD-1006 3-1 Chapter 71 WEBD System Messages WEBD-1001 3-1 WEBD-1002 3-1 WEBD-1003 3-1 WEBD-1004 3-2 WEBD-1005 3-2 WEBD-1006 3-2 WEBD- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 41
ZONE-1010 3-4 ZONE-1012 3-4 ZONE-1013 3-4 ZONE-1014 3-5 ZONE-1015 3-5 ZONE-1017 3-5 ZONE-1018 3-6 ZONE-1019 3-6 ZONE-1022 3-7 ZONE-1023 3-7 ZONE-1024 3-7 ZONE-1026 3-8 ZONE-1027 3-8 ZONE-1028 3-8 ZONE-1029 3-9 ZONE-1030 3-9 ZONE-1031 3-10 ZONE-1032 3-10 ZONE-1033 3-10 ZONE-1034 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 42
ZONE-1046 3-15 Section II Audit Log Messages Chapter 74 AUDIT AUTH System Messages AUTH-3001 74-1 AUTH-3002 74-1 AUTH-3003 74-2 Chapter 75 AUDIT CONF System Messages CONF-1000 3-1 CONF-1020 3-1 CONF-1022 3-2 Chapter 76 AUDIT HTTP System Messages HTTP-1002 3-1 HTTP-1003 3-1 Chapter 77 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 43
SEC-3014 3-6 SEC-3015 3-6 SEC-3016 3-6 SEC-3017 3-7 SEC-3018 3-7 SEC-3019 3-8 SEC-3020 3-8 SEC-3021 3-8 SEC-3022 3-9 SEC-3023 3-9 SEC-3024 3-9 SEC-3025 3-10 SEC-3026 3-10 SEC-3027 3-10 SEC-3028 3-11 SEC-3029 3-11 SEC-3030 3-11 SEC-3031 3-12 SEC-3032 3-12 SEC-3033 3-12 SEC-3034 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 44
SULB-1017 3-9 SULB-1018 3-10 SULB-1020 3-10 SULB-1021 3-11 SULB-1023 3-11 SULB-1024 3-11 SULB-1026 3-12 SULB-1030 3-12 SULB-1034 3-12 Chapter 80 AUDIT ZONE System Messages ZONE-3001 3-1 ZONE-3002 3-1 ZONE-3003 3-2 ZONE-3004 3-2 ZONE-3005 3-2 ZONE-3006 3-3 ZONE-3007 3-3 ZONE-3008 3-3 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 45
ZONE-3022 3-8 ZONE-3023 3-9 ZONE-3024 3-9 ZONE-3025 3-9 Fabric OS Message Reference xlv Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 46
xlvi Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 47
document is a command reference manual written to help system administrators and technicians operate, maintain, and troubleshoot SAN products. "About This Document" contains the following sections: • "How This Document Is Organized," next • "Supported Hardware and Software" on page xlvii • "What - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 48
Brocade SilkWorm 24000 director • Brocade SilkWorm 48000 director In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software 32, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 49
in the narrative portions of this guide are presented in mixed lettercase: lettercase is often all lowercase. Otherwise, this manual specifically notes those cases in which a firmware, software, or data. Warning A warning alerts you to potential danger to personnel. Key Terms For definitions of SAN - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 50
48000 Hardware Reference Manual • SilkWorm 48000 QuickStart Guide • FR4-18i Hardware Reference Manual • FR4-16IP Hardware Reference Manual SilkWorm 24000 • SilkWorm 24000 Hardware Reference Manual • SilkWorm 24000 QuickStart Guide SilkWorm 24000/48000 • Port Blade and Filler Panel Replacement - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 51
• SilkWorm 3250/3850 Hardware Reference Manual • SilkWorm 3250/3850 QuickStart Guide SilkWorm 200E SilkWorm 200E Hardware Reference Manual For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through: http://www.amazon - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 52
firmware. Optional Brocade Features Optional Brocade features include: Advanced Performance Monitoring Enables more effective end-to-end SAN Fabric OS supports eight FCIP interswitch links between two SilkWorm switches (SilkWorm 7500 or SilkWorm 48000 with a FR4-18i blade) or routes. All 16 links - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 53
Contact your switch support supplier for hardware, firmware, and software support, including problem and specific questions • Description of any troubleshooting steps already performed and results • Serial console and telnet session logs • syslog message logs 2. Switch Serial Number The switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 54
find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to: [email protected] Provide the title and version number and as much detail as possible about your issue, including the topic heading and page number and your - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 55
1 This guide supports Fabric OS v5.2.0 and documents system messages that you can use to diagnose and fix problems with the switch or fabric Logging Daemon (syslogd)" on page 1-2 • "System Console" on page 1-3 • "Port Logs" on page 1-3 System Message Log The Fabric OS maintains an internal system - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 56
is persistent across power cycles and switch reboots. • By switch from which the event was initiated. • Configuration: You can audit configuration downloads of existing SNMP configuration parameters. Configuration uploads are not audited. • Firmware: You can audit firmware download start, firmware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 57
log of all port activity. Each switch or logical switch maintains a log file for each port. Port logs are circular buffers that can save up to 8000 entries per logical switch. When the log is full, the newest log entries overwrite the oldest log entries. Port logs capture switch-todevice, device-to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 58
errClear Clears all error log messages for all switch instances on this control processor (CP). port error summary. portLogClear Clears the port log. If the port log is disabled, this commands enables it. portLogDisable Disables the port log facility. portLogDump Displays the port - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 59
(active CP only) information for the local CP and then transfers the files to an FTP server. The operation can take several minutes. supportShow Executes a list of diagnostic and error display commands. This output is used by your switch service provider to diagnose and correct problems with - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 60
-17:04:59, [FSSM-1003], 2,, WARNING, switch, HA State out of sync 2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port media incompatible. Reason: Configured port speed. 2004/07/28-17:04:54, [FABR-1001], 4,, WARNING, switch, port 4, ELP rejected by the other switch 2004/07/28-17:05:06 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 61
, HA State out of sync Type to continue, Q to stop: 2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port media incompatible e. Reason: Configured port speed. Type to continue, Q to stop: Clearing the System Message Log This procedure is valid for the SilkWorm 200E - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 62
(UTC) when the message was generated on the switch. The RASLog subsystem will support an internationalized timestamp format base on the "LOCAL" setting. [EM-1031] sequence number is persistent across power cycles and switch reboots. 1-8 Fabric OS Message Reference Publication Number: 53-1000242 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 63
16 characters in length. Run either the chassisName command to name the chassis or the switchName command to rename the logical switch. Slot 7 ejector not Error Description closed This field displays a text string explaining the error encountered and providing parameters supplied by the software - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 64
the message was generated on the switch. The RASLog subsystem will support an internationalized timestamp format base on the "LOCAL" setting. the event class as one of the following: Zone Security Configuration Firmware Fabric JohnSmith User ID Identifies the user ID. root Role Identifies the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 65
logical switch name. This field displays the defined switch name or the chassis name of the switch. This value is truncated if it is over 16 providing parameters supplied by the software at runtime. An example audit message as it appears in syslog: Dec 13 11:51:14[10.32.248.73.2.2]raslogd: AUDIT - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 66
guidelines for troubleshooting. For all cases, you should look at each specific error message description thoroughly before taking action. System messages have the following severity levels. 1 = CRITICAL Critical-level messages indicate that the software has detected serious problems that will - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 67
switch. port (console) logs available? 12. Which CP was master? (only applicable to the SilkWorm 12000, 24000, or 48000) 13. What and when were the last actions or changes made to the system? Support There are a number of files created to help support personnel to troubleshoot and diagnose a problem - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 68
downloaded using the saveCore command. The software watchdog process (SWD) is responsible for monitoring daemons critical to the function of a healthy switch files are intended for support personnel use only. Trace Dumps The Fabric OS produces trace dumps when problems are encountered within Fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 69
the domain and alias lists to all switches in the fabric. FABS Fabric OS system driver module. FBC Firmware blade compatibility errors with CP. FCIP Fibre Channel over IP port configuration messages. FCMC Fibre Channel miscellaneous messages relate to problems with the physical layer used to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 70
FICON-CUP switch nondisruptively during failures and software upgrades. These facilities include version negotiation, state information transfer, and internal synchronization functions, enabling the transition from standby to active operation. FSS is defined both as a component and a service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 71
iSCSI configurations not only switch wide, but also license, tunneling, and port related messages. ISCS The kernel software watchdog (FCPD) • FDMI daemon (FDMID) • FICON-CUP daemon (FICUD) • FSPF daemon (FSPFD) • ) • PS daemon (PSD) • Reliable commit service daemon (RCSD) • FA-API RPC daemon (RPCD - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 72
process or interrupt service routine (ISR) active CP blade to the standby CP blade. PDTR These messages indicate panic dump trace files have been created. PLAT This message indicates hardware problems. PORT PORT error messages refer to the front-end user ports on the switch. Front-end user ports - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 73
. Brocade switches support six management entities that can be configured to receive these traps. SS The supportSave command generates these error messages if problems are encountered. SULB The software upgrade library provides firmwareDownload command capability, which enables firmware upgrades - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 74
, refer to the Fabric OS Command Reference or the Fabric OS Administrator's Guide. TS Time Service provides fabric time-synchronization by synchronizing all clocks in the fabric to the clock time on the principal switch. UCST UCAST is a part of the fabric shortest path first (FSPF) protocol - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 75
RASLog Messages This section provides the RASLog messages, including: • AUTH System Messages • BL System Messages • BLL System Messages • BM System Messages • CDR System Messages • CER System Messages • CONF System Messages • EM System Messages • EVMD System Messages • FABR System Messages • FABS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 76
Messages • MS System Messages • NBFS System Messages • NS System Messages • PDM System Messages • PDTR System Messages • PLAT System Messages • PORT System Messages • PS System Messages • PSWP System Messages • RAS System Messages • RCS System Messages • RPCD System Messages • RTWR System Messages - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 77
• WEBD System Messages • ZOLB System Messages • ZONE System Messages Fabric OS Message Reference I-3 Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 78
I-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 79
the secAuthSecret command. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1003 Message , [AUTH-1003], ,, INFO, , type has been successfully set - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 80
an authentication file corruption. Run the firmwareDownload command to reinstall the firmware. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1006 Message , [AUTH-1006], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 81
Cause Recommended Action Severity Indicates an internal problem with the Secure Fabric OS. Reinitialize switch service provider. WARNING AUTH-1007 Message , [AUTH-1007], ,, ERROR, , The proposed authentication protocol(s) are not supported: port - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 82
Action Severity Indicates an internal problem with the Secure Fabric OS. Reboot or power cycle the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR AUTH-1011 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 83
command and contact your switch service provider. WARNING AUTH-1014 Message , [AUTH-1014], , FFDC, ERROR, , Invalid port value to : port Probable Cause Recommended Action Severity Indicates an internal problem with the Secure - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 84
; then run the supportSave command and contact your switch service provider. ERROR AUTH-1018 Message , [AUTH-1018], ,, ERROR, , Invalid value to check protocol type: port Probable Indicates an internal problem with the Secure Fabric OS. Cause - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 85
port number>. Probable Cause Recommended Action Severity Indicates the authentication process failed to extract a particular value from the receiving payload. Usually this problem command and contact your switch service provider. ERROR AUTH to the switch. Check the connection port for possible - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 86
port number> Probable Cause Recommended Action Severity Indicates the authentication process failed to get the expected information during the specified authentication phase. Usually this problem the supportSave command and contact your switch service provider. ERROR AUTH-1028 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 87
; then run the supportSave command and contact your switch service provider. ERROR AUTH-1029 Message , [AUTH port Probable Cause Recommended Action Indicates the receiving payload does not have valid message code for a particular authentication phase. Usually this problem - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 88
then run the supportSave command and contact your switch service provider. ERROR AUTH-1031 Message , , error code , port Probable Cause Recommended Action Severity Indicates replay attacks. Usually this problem is transient. The authentication - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 89
supportSave command and contact your switch service provider. ERROR AUTH-1035 port number> Probable Cause Recommended Action Indicates that a particular data field in the authentication message has an invalid length field. This error usually relates to internal failure. Usually this problem - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 90
port Probable Indicates that the switch received an unexpected authentication message. Cause Recommended Action Usually this problem FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1037 Message , [AUTH-1037 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 91
system-name>, Failed to retrieve certificate during : port Probable Cause Recommended Action Severity Indicates that the PKI run the supportSave command and contact your switch service provider. ERROR Fabric OS Message Reference Publication Number: 53-1000242- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 92
2 AUTH-1038 2-14 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 93
Messages Chapter 3 BL-1000 Message , [BL-1000], ,, INFO, , Initializing Ports... Probable Indicates that the switch has started initializing the ports. Cause Recommended No action is required. Action Severity INFO BL-1001 Message , [BL-1001 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 94
one or more of the internal ports was not online. The blade is faulted. Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Refer to the Fabric OS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 95
Probable Cause Recommended Action Severity Indicates that the errors (mostly synchronization errors) on this blade are harmless. Probably, the standby CP blade connected to the active CP blade has experienced transitory problems. Verify that the standby CP is healthy. If the standby CP was removed - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 96
to initialize the ASIC chips. Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Refer to the Fabric OS Command Reference for more information - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 97
device attached to the specified port. Run the systemVerification command to verify that the blade or switch does not have hardware problems. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power cycle the switch. If the message persists, replace - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 98
for a faulty cable, SFP, or device attached to the specified port. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power cycle the switch. If the message persists, replace the blade. ERROR BL-1014 Message , [BL-1014], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 99
Indicates that the specified blade port has failed to get enabled. Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Refer to the Fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 100
Action Severity Indicates that the slot has completed initializing the ports. No action is required. INFO BL-1019 Message < switch has failed to initialize the ASIC chips. Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 101
initiation failed because one or more of the internal ports was not online. The switch is faulted. Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on this - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 102
Action Severity Reboot or power cycle the blade. If the message persists, replace the blade. CRITICAL BL-1024 Message , [BL-1024], ,, INFO, , All ports on the blade in slot will be reset as part of the firmware upgrade. Probable Cause - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 103
Reboot or power cycle the switch. If the message persists, replace the switch. CRITICAL BL-1029 Message , [BL-1029], ,, INFO, , All ports on the switch will be reset as part of the firmware upgrade. Probable Indicates that a recent firmware upgrade caused - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 104
], ,, INFO, , All GigE/FCIP ports on the switch will be reset as part of the firmware upgrade. Probable Cause Recommended Action Severity Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 105
out while waiting for disable messages from the user ports after disabling the ports. Reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. If the message persists, replace the blade. Refer to the Fabric OS Command Reference for - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 106
], ,, INFO, , Slot iSCSI port Initialization Completed Probable Cause Recommended Action Severity Indicates that the indicated slot has completed initializing specified iSCSI port. No action is required. INFO 3-14 Fabric OS Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 107
FFDC, CRITICAL, , ASIC driver detected Slot port as faulty (reason: ) Probable Cause Indicates that a blade regulation problem was reported on the specified slot number. The blade is faulted. All blade register fault codes are associated with BLOOM - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 108
• 22 = BISR or RAMINIT error Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Refer to the Fabric OS Command Reference for more information on - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 109
the AP blade The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmwareDownload is supported between the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 110
to the BP to communicate. Reseat the blade. If the problem persists, power-cycle the blade using the slotPowerOff and slotPowerOn commands. WARNING BM-1004 Message , [BM-1004], ,, INFO, , Blade firmware on slot < Slot > is not consistent - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 111
blade requires these port configurations to be cleared. The blade was detected for the first time after an FR4-18i was previously configured in the same slot. No action is required. INFO BM-1008 Message , [BM-1008], ,, WARNING, , Download of blade firmware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 112
blade will automatically download the updated firmware. Action Severity INFO BM-1055 Message , [BM-1055], ,, WARNING, , Firmwaredownload timed-out for AP. Faulting switch. Probable Cause Recommended Action FirmwareDownload of the AP failed. Power-cycle - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 113
was configured under a different mode Configure the switch and persistently enable the ports. INFO BM-1058 Message , [BM-1058], ,, WARNING, , Download of AP firmware failed for the switch. Reissue firmwaredownload to recover. Probable Cause Recommended - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 114
5 BM-1058 5-6 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 115
Recommended Action Severity Internal error. All the ports on the blade or switch will be disrupted. For a bladed system, issue the slotPowerOff and slotPowerOn commands on the blade to recover the system. For a non-bladed system, perform fastBoot on the switch to recover the system. ERROR Fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 116
6 CDR-1002 6-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 117
Probable Cause Recommended Action Severity Indicates that the HA synchronization between the active and standby CPs is broken because there is downlevel firmware loaded on the standby CP. The standby CP does not support the Advanced Performance Tuning module when FICON Management Server is enabled - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 118
7 CER-1001 7-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 119
operation was initiated and completed successfully. The message string that follows is a description of the class of configuration parameters that were downloaded. If AD is enabled, the AD number is specified in the description. No action is required. INFO CONF-1001 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 120
Action Severity Indicates that an attempt to download the configuration without disabling the switch was unsuccessful because there are one or more parameters that require the switch to be disabled. Disable the switch and try to download configuration again. INFO 8-2 Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 121
are dumped to the console. Verify that the location temperature is within the operational range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Run the fanShow command to verify that all fans are running at normal speeds. If any fans - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 122
FRU is faulted. On SilkWorm 24000 and 48000, try reseating the specified FRU. Reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on this command. On the SilkWorm - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 123
; the voltage is too low. If this problem occurs on a blade, it usually indicates a hardware problem on the blade; replace the blade. If this problem occurs on a switch, it usually indicates a hardware problem on the main board; replace the switch. CRITICAL EM-1007 Message , [EM-1007 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 124
, 3250, 3850, 4100, and 4900 replace the switch. CRITICAL EM-1008 Message , [EM-1008], Manual for more information about chassisConfig modes and supported blades. CRITICAL EM-1010 Message , [EM-1010], , FFDC, CRITICAL, , Received unexpected power - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 125
faulted Probable Cause Recommended Action Severity Indicates that a switch blade or nonbladed switch failed to transition from one state to another. It persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 126
Action Severity Indicates that a problem was discovered when performing consistency checks during a warm boot. A reboot or power cycle is required to clear Action Indicates that a problem was discovered when performing consistency checks during a cold boot. Monitor the switch. 9-6 Fabric OS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 127
command and contact your switch service provider. WARNING EM-1017 power cycle, or firmwareDownload operation. Change and commit the new WWN value. WARNING EM-1018 Message , [EM-1018], , FFDC, CRITICAL, , CP blade is not supported by the firmware on the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 128
firmware on the standby to the version running on the active . The problems were encountered when the software attempted to problem. The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or port. If the message persists, reboot or power cycle the switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 129
, or completely screw in the upper thumbscrew for the FC4-48 port blade) if the FRU is intended for use. Refer to the appropriate hardware manual for instructions on inserting the switch blades. ERROR EM-1033 Message , [EM-1033], ,, ERROR, , CP in - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 130
card, then default WWN and IP addresses are used for the switch. Reseat the FRU card. If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 131
Severity Indicates that the specified Power Supply has been marked as no longer being faulty. Probably because its AC power supply has been turned on. RPM If the message is isolated, monitor the error messages on the switch. If the message is associated with other messages, follow the recommended - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 132
Can't power on , its logical switch is port blade. If new_state is On, a port blade is being powered on because more power is available (either a power supply was inserted or a port blade was removed or powered down). If new_state is Off, a port blade has been powered down because a power - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 133
port blades installed, two power supplies are sufficient for redundancy; however, when one or more AP blades have been installed, four power access recovered: state Probable Indicates that the I2C bus problems have been resolved and I2C access to the FRU has become Cause available - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 134
9 EM-1049 Recommended Action Severity The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is displayed. INFO EM-1049 Message , [EM-1049], ,, INFO, , FRU insertion detected. Probable - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 135
can be run at the configured port speed. If the port media is extended long wavelength, move it to a port that can support the heat generated. WARNING EM- switch does not reach the reset threshold for the switch/blade. If the reset Action threshold is reached on the switch/blade, the switch/blade - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 136
switch type. CRITICAL EM-1060 Message , [EM-1060], ,, WARNING, , Stopping synchronization of the system due to blade incompatibility with software version on standby CP. Probable Cause Recommended Action Severity A blade in the system is not supported - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 137
synchronization. WARNING EM-1062 Message , [EM-1062], ,, CRITICAL, , Blade in slot faulted as it exceeds the maximum support limit of blades with Blade ID in the chassis. Probable Cause Recommended Action Severity Too many - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 138
slot will be 0 for non-bladed systems. On bladed systems, try reseating the specified FRU. On nonbladed switches, reboot or power cycle the switch. If the problem persists: • Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 139
], ,, WARNING, , Event could not be sent to remote proxy. = Probable The event could not be sent to the remote proxy because the remote proxy switch cannot be reached Cause through in-band. Recommended Please make sure that the specified remote - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 140
10 EVMD-1001 10-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 141
>, Probable Cause Recommended Action Severity Indicates that the specified switch port is isolated because of a segmentation due to mismatched configuration parameters. Based on the segmentation reason displayed within the message, look for a possible mismatch of relevant - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 142
service (ILS) information unit of invalid size has been received. The neighbor switch has sent an invalid sized payload. Investigate the neighbor switch for problems. Run the errShow command on the neighbor switch ports. Run the fabStateShow command on both the receiving and transmitting switches. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 143
port is about to go down. No action is required; this message is often transitory. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service is rare and usually indicates a problem with the Fabric OS. In - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 144
to a faulty EFP type. This message is rare and usually indicates a problem with the Fabric OS. The fabric daemon will discard the EFP. The system automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING FABR-1010 Message , [FABR-1010], < - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 145
or unstable. This message is rare and usually indicates a problem with the Fabric OS. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR FABR-1012 Message , [FABR-1012 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 146
is not enough memory in the switch for the fabric module to allocate. This message is rare and usually indicates a problem with the Fabric OS. The your switch service provider. CRITICAL FABR-1014 Message , [FABR-1014], , FFDC, ERROR, , Port - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 147
, [FABR-1017], ,, WARNING, , ficonMode is disabled. Probable Indicates that FICON mode is disabled on the switch through a user interface command. Cause Recommended No action is required. Action Severity WARNING FABR-1018 Message , [FABR-1018 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 148
>, FFDC, CRITICAL, , Critical fabric size () exceeds supported configuration () Probable Cause Recommended Action Severity Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a specified limit to the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 149
changed to within the licensed limit. Contact your switch provider to obtain a full fabric license. CRITICAL FABR-1023 Message , [FABR-1023], ,, INFO, , Fabric size is within supported configuration (). Fabric limit timer () stopped - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 150
size of the fabric must be changed to within the licensed limit. Contact your switch provider to obtain a full fabric license. INFO FABR-1029 Message , [FABR-1029], ,, INFO, , Port - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 151
> exceeded. Probable Cause Recommended Action Severity Indicates that fabric exhausted the maximum number of retries sending ILSes to iswitchd on the logical E-port. Run the top command to see if iswitchd is extremely busy or if another process is using excessive CPU resources. WARNING Fabric OS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 152
11 FABR-1031 11-12 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 153
Severity Indicates that an internal problem has been detected by the software. This is usually an internal Fabric OS problem or file corruption. Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. WARNING FABS-1004 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 154
ID (PID), which could be any whole number. Reboot or power cycle the active CP (for modular systems) or the switch (for single-board systems). If the message persists, run the firmwareDownload command to update the firmware. WARNING FABS-1006 Message , [FABS-1006], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 155
value in an object's status field. This is usually an internal Fabric OS problem or file corruption. Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. WARNING FABS-1008 Message , [FABS-1008], ,, WARNING - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 156
an unknown event type. This is usually an internal Fabric OS problem or file corruption. Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. WARNING FABS-1011 Message , [FABS-1011], ,, ERROR, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 157
FRU header, or the blade may not be supported by this platform or Fabric OS version. Verify that the blade is valid for use in this system and this version of Fabric OS. Try reseating the blade. If this is a valid blade and reseating does not fix the problem, then replace the blade. ERROR FABS-1014 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 158
could not be enabled. This is usually an internal Fabric OS problem. Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. ERROR 12-6 Fabric OS Message Reference Publication Number: 53-1000242 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 159
the CP. The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmwareDownload is supported between the versions - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 160
13 FBC-1001 13-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 161
FCIP System Messages Chapter 14 FCIP-1000 Message , [FCIP-1000], , FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= rsn= fn= oid= - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 162
14 FCIP-1000 14-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 163
failed to allocate new memory for an information unit (IU). A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically fail over and the standby CP will become the active CP. CRITICAL Fabric OS Message Reference Publication Number: 53-1000242-01 15 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 164
15 FCMC-1001 15-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 165
alpa_number • F_Port port_number This can happen when the firmware on the device controller on the specified port has a defect. Check with the device vendor for a firmware upgrade containing a defect fix. The SilkWorm 4100 does not support private loop devices. WARNING FCPD-1002 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 166
Cause Recommended Action Severity Private devices will not respond to the switch PLOGI during probing. Refer to the switch vendor for a list of other port types that support private devices for inclusion into the fabric. INFO 16-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 167
" fc_create". This function creates a Fibre Channel driver instance. The failed function call is "kmalloc_wrapper failed". This function call is for kernel memory allocation. A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically fail over, and the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 168
17 FCPH-1001 17-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 169
. Action Severity INFO FCR-1002 Message , [FCR-1002], ,, INFO, , FC router proxy device in edge deleted at port . Probable Cause Recommended Action Severity Indicates that a proxy device in the edge fabric has been deleted at the specified - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 170
No action is required. INFO FCR-1006 Message , [FCR-1006], ,, INFO, , FC router LSAN zone device added at port . Probable Indicates that a device is added to an LSAN zone in the edge fabric. Cause Recommended No action is required. Action 18 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 171
number>: . Probable Indicates that an LSAN zone was enabled in the edge fabric attached to the specified port. The enabled Cause LSAN zone configuration is listed. Recommended No action is required. Action Severity INFO Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 172
18 FCR-1010 FCR-1010 Message , [FCR-1010], ,, INFO, , FC router LSAN zone disabled at port . Probable Cause Recommended Action Severity Indicates that an LSAN zone is disabled in the edge fabric. No action is required. INFO FCR-1011 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 173
id fabric ID . Probable Indicates that a fabric is no longer accessible through the backbone fabric. This can be caused by a link Cause or switch failure. Recommended No action is required. Action Severity INFO Fabric OS Message Reference Publication Number: 53-1000242 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 174
. Use the fcrProxyDevShow command to view how many proxy devices are created in the fabric with the port resource problem. LSAN zones are removed using standard zoning commands such as zoneShow, zoneRemove, zoneDelete, cfgDelete, and cfgDisable in the edge fabric. Proxy devices can be removed - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 175
FCR-1023 Message , [FCR-1023], ,, WARNING, , Local phantom port WWN entries exhausted. Probable Indicates that the number of port WWNs in use is greater than the local port WWN resources. Cause Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 176
translate domains). You can also limit the number of proxy devices for a translate domain (which limits the number of translate domain ports required) by limiting the devices specified in LSAN zones. WARNING FCR-1024 Message , [FCR-1024], ,, WARNING, , Local - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 177
conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of LSAN devices and fabrics, or there are highly dynamic changes to EX port connectivity. WWN conflicts might cause unpredictable behavior in management applications - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 178
conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of LSAN devices and fabrics, or there are highly dynamic changes to EX port connectivity. WWN conflicts might cause unpredictable behavior in management applications - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 179
. No action is required. INFO FCR-1033 Message , [FCR-1033], ,, INFO, , Edge fabric disabled security on port in fabric . Probable Cause Recommended Action Severity Indicates that Secure mode was turned off in the edge fabric. No - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 180
18 FCR-1035 FCR-1035 Message , [FCR-1035], ,, INFO, , LSAN zone device added in the backbone fabric. Probable Cause Recommended Action Severity Indicates that a new device was added to an LSAN zone in the backbone fabric. No action is required. INFO FCR- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 181
>. Probable Cause Recommended Action Severity Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the local switch's zone database limitations. Remove excess cfg/zone/alias entries so that the number of LSAN zones created is within the range of the local - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 182
18 FCR-1041 FCR-1041 Message , [FCR-1041], ,, INFO, , LSAN zone device removed in the backbone fabric. Probable Cause Recommended Action Severity Indicates that an LSAN zone device within the backbone fabric was removed. No action is required. INFO FCR- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 183
Severity Indicates that an incoming ELP command was issued and it is not supported. Run the portEnable and portDisable commands to enable and disable the port. If the problem persists contact your switch service provider. ERROR FCR-1053 Message , [FCR-1053], ,, WARNING - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 184
>,, WARNING, , Port received ILS of incorrect size (); valid ILS size is . Probable Cause Recommended Action Severity Indicates that an internal link service (ILS) IU of invalid size was received from the switch on the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 185
if backbone to edge routing is not needed. Otherwise replace the switch with one that supports backbone to edge routing. INFO FCR-1057 Message , [FCR-1057], ,, ERROR, , EX port() incompatible long distance parameters on link. Probable Cause - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 186
() has an incompatible configuration setting. Probable Cause Recommended Action Severity Indicates that VC Link Init is enabled on the local switch and the remote switch is negotiating in R_RDY mode. The fabric might not form properly. Check the configuration on the local switch using - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 187
the maximum number of supported ports was exceeded. To enable this port, disable any other operational port then re-enable the port. No action is required. INFO FCR-1063 Message , [FCR-1063], ,, INFO, , Fabric for switch with domain ID: - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 188
port was assigned two different fabric IDs. Probable Cause Recommended Action Severity Indicates that another port on the switch this port. If the fabric split, then merge the fabrics and manually re-enable the port. If supported by the Fibre Channel. The limit includes both active - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 189
is disabled. This is caused by fcrDisable, configDefault, or a configDownload with the fcrState set to 2 (disabled). Note that the FC Routing service is disabled by the factory. No action is required. INFO FCR-1069 Message , [FCR-1069], ,, INFO, , The - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 190
is no longer an EX or VEX port. No action is required. INFO FCR-1073 Message , [FCR-1073], ,, INFO, , Switch with domain ID in fabric has lower limit of LSAN Zones supported Probable Cause Recommended Action Severity Indicates that - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 191
for this RNID. The error variable is an internal error number. If this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference for more - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 192
switch. Run the licenseShow command to check the installed licenses on the switch. The switch cannot be managed using FICON-CUP commands until the FICON-CUP license is installed. Contact your switch supplier for a FICON-CUP Refer to the Fabric OS Administrator's Guide for information on core PID mode - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 193
-CUP daemon failed. Download a new firmware problem. If the message persists, check the memory usage on the switch , using the memShow command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 194
) was enabled. This is due to port address conflict or port address being reserved for CUP management port No action is required. WARNING FICU-1009 available on some of the ports. Use the perfDelFilterMonitor command to delete the filter-based performance monitors used on all ports to free up the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 195
overlapped, pid= Probable Cause Recommended Action Severity Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out exchange; it - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 196
20 FKLB-1001 20-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 197
FLOD System Messages Chapter 21 FLOD-1001 Message , [FLOD-1001], , FFDC, WARNING, , Unknown LSR type: port , type Probable Cause Recommended Action Severity Indicates that the link state record (LSR) type is unknown. 1- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 198
-1005 Probable Cause Recommended Action Severity Indicates that the LSU size exceeds what the system can support. Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two switches. ERROR FLOD-1005 Message , [FLOD-1005], ,, WARNING - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 199
1001 Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Indicates that the specified input port number is out of range; it does not exist on the switch. Cause Recommended No action is required. Action Severity ERROR FSPF-1002 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 200
fabric. SilkWorm switches support only section ID supported, input port = Probable Cause Recommended Action Severity Indicates that the FSPF version is not supported on the specified input port. Update the FSPF version by running the firmwareDownload command to update the firmware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 201
persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING FSS-1002 Message , [FSS-1002], ,, WARNING, , Component () sending too many concurrent - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 202
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR FSS-1005 Message , [FSS-1005], ,, WARNING, , FSS read failure Probable Indicates that the read - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 203
Cause Recommended Action Severity Indicates that the Ethernet connection is not healthy. Check the Ethernet connection and issue the haSyncStart command. If the problem persists, contact your switch service provider. CRITICAL Fabric OS Message Reference Publication Number: 53-1000242-01 23-3 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 204
23 FSS-1007 23-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 205
Action Severity Indicates that the HA state for the active CP is in synchronization with the HA state of the active CP is out of synchronization with the HA state of the standby CP. If the active CP Otherwise, issue the haSyncStart command on the active CP and try resynchronizing the HA state. If - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 206
Incompatible software version in HA synchronization. Probable Cause Recommended Action Severity Indicates that the active CP and the standby CP in a dual CP system are running firmware that are incompatible with each other. If the active CP fails, the failover will be disruptive. In a non-bladed - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 207
that the fans and airflow of a switch are functioning normally. Verify that the location temperature is within the operational range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. WARNING Fabric OS Message Reference Publication Number - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 208
Probable Cause Recommended Action Severity Indicates that the internal temperature of the switch has changed from a value outside of the acceptable range to a the speed of the fan has changed. Fan problems typically contribute to temperature problems. No action is required. Respond to this - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 209
>. Probable Cause Recommended Action Severity Indicates that the speed of the fan has fallen below the low boundary. Fan problems typically contribute to temperature problems. Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan FRU. WARNING FW-1007 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 210
that it is seated correctly in the chassis. Run the psShow command to view the status of the power supply. If the power supply continues to be a problem, replace the faulty power supply. INFO FW-1010 Message , [FW-1010], ,, WARNING, , , is below low - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 211
and low boundaries(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the power supply counter changed from a value outside of the acceptable range to a value within the acceptable range. No action is required. Respond to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 212
INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the receive power value of the SFP has changed. The receive performance area measures the amount of incoming laser to help you determine if the SFP is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 213
is below low boundary(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the receive power value of the SFP has fallen below the low boundary. The receive performance area measures the amount of incoming laser to help you - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 214
value has changed(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the transmit power value of the SFP has changed. The transmit performance area measures the amount of outgoing laser to help you determine if the SFP is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 215
above high boundary(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the transmit power value of the SFP has risen above the high boundary. The transmit performance area measures the amount of outgoing laser to help you - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 216
25 FW-1046 Severity INFO FW-1046 Message , [FW-1046], ,, WARNING, , , is below low boundary(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the value of the SFP - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 217
FW-1049 25 Severity INFO FW-1049 Message , [FW-1049], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Indicates that the value of the SFP voltage has changed. Frequent voltage - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 218
SFP. SFP failures also cause E_Ports to go down. E_Port downs might be caused by transient errors. A low number of E_Port failures means that the switch is functioning normally. 25-12 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 219
FW-1115 25 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1115 Message , [FW-1115], ,, INFO, , , is above high boundary(High=, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 220
. The following actions can cause a fabric reconfiguration: • two switches with the same domain ID have connected to one another. • inexplicable fabric reconfiguration might be a transient error and might not require troubleshooting. INFO FW-1118 Message , [FW-1118], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 221
fabric reconfiguration might be a transient error and might not require troubleshooting. INFO FW-1120 Message , [FW-1120], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 222
single fabric and the principal switch has to assign another domain ID to the switch. A low number of fabric and the principal switch has to assign another domain ID to the switch. No action is fabric and the principal switch has to assign another domain ID to the switch. No action is required - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 223
might occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. No action is required. Respond to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 224
might occur due to: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. No action is required. Respond to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 225
FW-1129 25 FW-1129 Message , [FW-1129], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of zone changes has changed. Zone - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 226
Current value is . Probable Cause Recommended Action Severity Indicates that the number of fabric logins has changed. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. No action is required. Respond to this message as - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 227
that the number of fabric logins has changed from a value outside of the acceptable range to a value within the acceptable range. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login or FLOGI. No action is required. Respond to this message as is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 228
below the low boundary. SFP state changes occur when the SFP is inserted or removed. A low number of SFP state changes means that the switch is functioning normally. No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 229
failures that the port experiences has fallen problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 230
port experiences has risen above the high boundary. Link loss errors occur when a link experiences a loss of signal and fails. Both physical and hardware problems continue to experience synchronization loss errors, troubleshoot your HBA and contact your switch service provider. INFO 25-24 Fabric OS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 231
are not faulty. If you continue to experience loss-of-synchronization errors, troubleshoot your HBA and contact your switch service provider. WARNING FW-1167 Message , [FW-1167], ,, INFO, , , , is between high and low boundaries(High= - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 232
number of signal losses that the port experiences has changed. Loss of signal generally indicates a physical problem. Check both ends of your cable means that the switch is functioning normally. INFO FW-1170 Message , [FW-1170], ,, WARNING, , , < - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 233
Recommended Action Severity Indicates that the number of protocol errors that the port experiences has changed. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. Check both ends of your cable connection. Verify that the cable and - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 234
the number of protocol errors that the port experiences has fallen below the low boundary. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. No action is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 235
Severity Indicates that the number of invalid words that the port experiences has fallen below the low boundary. Invalid words usually indicate a hardware problem with an SFP or cable. A low number of invalid words means that the switch is functioning normally. No action is required. Respond to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 236
acceptable range. Invalid words usually indicate a hardware problem with an SFP or cable. No action is required Indicates that the number of invalid CRCs that the port experiences has fallen below the low boundary. Cause means that the switch is functioning normally. Severity INFO 25-30 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 237
value>, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the percentage of incoming traffic that the port experiences has changed. No action is required. Respond to this message as is appropriate to the particular policy of the end-user - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 238
Probable Cause Recommended Action Severity Indicates that the percentage of incoming traffic that the port experiences has fallen below the low boundary. No action is required. Respond to this of the end-user installation. INFO 25-32 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 239
Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the percentage of outgoing traffic that the port experiences has fallen below the low boundary. No action is required. Respond to this message as is appropriate to the particular policy of - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 240
has gone offline, has come online, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. A low number of port state changes means that the switch is functioning normally. 25-34 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 241
has gone offline, has come online, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1216 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 242
should set your high boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem in this area. A low level of invalid CRC errors means that the switch is functioning normally. No action is required. Respond to this message as is appropriate to the particular policy - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 243
, temperature fluctuations, and aging equipment. You should set your high boundaries to fiveor six-digit figures, as only large numbers of messages indicate a problem in this area. No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 244
25 FW-1242 Probable Cause Recommended Action Severity Indicates that the number of EE CRC errors has fallen below the low boundary. Invalid CRC messages occur when the number of CRC errors in Fibre Channel frames for specific source ID (S_ID) and destination ID (D_ID) pairs change. These messages - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 245
Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of EE word frames that the switch receives has changed. Receive performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 246
>, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of EE word frames that the switch transmits has changed. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 247
=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of EE word frames that the switch transmits has risen above the high boundary. Transmit performance messages appear due to the number of word frames that travel from the configured - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 248
value is . Probable Cause Recommended Action Severity Indicates that the number of frame types or commands that the port receives has fallen below the low boundary. The port has received SCSI Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a frame. No action is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 249
Indicates that the number of frame types or commands that the port receives has changed from a value outside of the acceptable range to a list of TCP/IP addresses that are authorized to establish telnet connections to switches in the fabric. The IP addresses use standard "dot" notation (for - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 250
been received from an unauthorized IP address. The TELNET_POLICY contains a list of TCP/IP addresses that are authorized to establish telnet connections to switches in the fabric. The IP addresses use standard "dot" notation (for example, 255.255.255.255). Run the errShow command to determine the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 251
been received from an unauthorized IP address. The HTTP_POLICY contains a list of TCP/IP addresses that are authorized to establish browser connections to the switches in the fabric. The IP addresses use the standard "dot" notation (for example, 255.255.255.255). Run the errShow command to determine - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 252
been received from an unauthorized IP address. The HTTP_POLICY contains a list of TCP/IP addresses that are authorized to establish browser connections to the switches in the fabric. The IP addresses use the standard "dot" notation (for example, 255.255.255.255). No action is required. INFO FW-1304 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 253
has been received from an unauthorized IP address. The SNMP_POLICY contains a list of TCP/IP addresses that are authorized to establish API connections to switches in the fabric. The IP addresses use standard "dot" notation (for example, 255.255.255.255). Run the errShow command to determine the IP - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 254
The SNMP_POLICY contains a list of TCP/IP addresses that are authorized to establish API connections to switches in the fabric. The IP addresses use standard "dot" notation (for example, 255.255 address. No action is required. INFO 25-48 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 255
FW-1310 25 FW-1310 Message , [FW-1310], ,, WARNING, , , is above high boundary(High=, Low=). Current value is . Probable Cause Recommended Action Severity Indicates that the number of RSNMP violations has risen - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 256
25 FW-1313 Severity INFO FW-1313 Message , [FW-1313], ,, INFO, , , is below low boundary(High=, Low=). Current value is . Probable Indicates that the number of WSNMP violations has fallen below the low boundary. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 257
that the number of SES violations has changed. SES violations indicate that an SCSI Enclosure Services (SES) request has been received from an unauthorized WWN. The SES_POLICY contains a list of WWNs of device ports that are allowed to access the SES Server functionality. Run the errShow command to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 258
violations has risen above the high boundary. SES violations indicate that an SCSI Enclosure Services (SES) request has been received from an unauthorized WWN. The SES_POLICY contains a list of WWNs of device ports that are allowed to access the SES Server functionality. Run the errShow command to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 259
violations indicate that a Management Server (MS) access request has been received from an unauthorized WWN. The MS_POLICY contains a list of WWNs of device ports that are allowed to access the Management Server functionality. Run the errShow command to determine the WWN of the device that sent the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 260
Indicates that the number of serial violations has changed. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch WWNs for which serial port access is enabled. Run the errShow command to determine the WWN of the device that - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 261
of serial violations has risen above the high boundary. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch WWNs for which serial port access is enabled. Run the errShow command to determine the WWN of the device that - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 262
risen above the high boundary. Front panel violations indicate that an unauthorized front panel request has been received. The FRONTPANEL_POLICY contains a list of switch WWNs for which front panel access is enabled. Run the errShow command to determine the WWN of the device that sent the request - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 263
Indicates that the number of SCC violations has fallen below the low boundary. SCC violations indicate that an unauthorized switch tried to join the fabric. The SCC_POLICY contains a list of switches by WWN that are allowed to be members of a fabric. No action is required. INFO FW-1334 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 264
that an unauthorized device tried to join the fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs an FLOGI request, the WWN specified in the FLOGI is validated to be - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 265
that an unauthorized device tried to join the fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs an FLOGI request, the WWN specified in the FLOGI is validated to be - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 266
that an unauthorized device tried to join the fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs an FLOGI request that the WWN specified in the FLOGI is validated to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 267
has been received from the primary FCS. When the primary fabric configuration server (FCS) downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference is too great, it - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 268
has been received from the primary FCS. When the primary fabric configuration server (FCS) downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference is too great, it - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 269
violations indicate that a packet with an invalid signature has been received from the primary FCS. When the primary fabric configuration server (FCS) downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 270
the primary fabric configuration server (FCS) downloads a new configuration to the other switches in the fabric, the packet is signed switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid signatures. No action is required. 25-64 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 271
from the primary FCS. Before a new primary FCS switch sends any configuration data to any switch in the fabric, it first sends its certificate to all the switches in the fabric. The receiving switch has to verify that the sender is the primary FCS switch and its certificate is signed by the Root CA - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 272
from the primary FCS. Before a new primary FCS switch sends any configuration data to any switch in the fabric, it first sends its certificate to all the switches in the fabric. The receiving switch has to verify that the sender is the primary FCS switch and its certificate is signed by the Root CA - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 273
the low boundary. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 274
the acceptable range. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 275
(High=, Low=). Current value is . Probable Cause Recommended Action Indicates that the number of time service (TS) out-of-sync violations has changed. Responses to security-class messages depend on user policies. Consult your security administrator for response - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 276
Label>, is below low boundary(High=, Low=). Current value is . Probable Indicates that the number of time service out-of-sync violations has fallen below the low boundary. Cause Recommended No action is required. Action Severity INFO FW-1366 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 277
has changed. This counter records how often the switch loses contact with the primary FCS switch. When the primary FCS switch in the fabric sends its certificate to a switch, the receiving switch saves the WWN of that primary FCS switch. If a secure switch finds that there are no FCSs in the fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 278
the high boundary. This counter records how often the switch loses contact with the primary FCS switch. When the primary FCS switch in the fabric sends its certificate to a switch, the receiving switch saves the WWN of that primary FCS switch. If a secure switch finds that there are no FCSs in the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 279
has fallen below the low boundary. This violation indicates the number of secure switches with different version stamps have been detected. When a switch is in secure mode, it connects only to another switch that is in secure mode and has a compatible security database. A compatible security - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 280
the low boundary. This counter tracks how many times commands allowed only on the primary FCS switch have been executed on a nonprimary FCS switch. There are many commands that can be executed only on the primary FCS switch as well as one security command that can be executed only on a backup FCS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 281
value is . Probable Indicates that the flash usage percentage has changed. Flash increases and decreases slightly with Cause normal operation of the switch. Excessive permanent increases can lead to future problems. Fabric OS Message Reference Publication Number: 53-1000242-01 25-75 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 282
flash usage percentage has risen above the high boundary. Flash increases and decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. You might have to remove some unwanted files to create some flash space. Run the saveCore command to remove - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 283
decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. No action is required. Respond to FW-1426], ,, WARNING, , Switch status change contributing factor Power supply: bad, absent - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 284
FW-1427 Message , [FW-1427], ,, WARNING, , Switch status change contributing factor Power supply: bad. Probable Cause Recommended Action Severity Indicates that the switch status is not in a healthy state. This occurred because the number of - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 285
FW-1430 25 Probable Cause Recommended Action Severity Indicates that the switch status is not in a healthy state. This occurred because the power supplies are not in the correct slots for redundancy. Rearrange the power supplies so that one is in an odd slot and other in an even slot to make them - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 286
same level of firmware to both CPs. Replace any faulty CPs. If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was up on a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to clear the problem. WARNING FW-1434 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 287
. WARNING FW-1436 Message , [FW-1436], ,, WARNING, , Switch status change contributing factor Marginal ports: marginal ports. (Port(s) ) Probable Cause Recommended Action Severity Indicates that the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 288
command to modify the SFP policy or to add SFPs to the empty ports. Action Severity WARNING FW-1439 Message , [FW-1439], ,, WARNING, , Switch status change contributing factor Switch offline. Probable Cause Recommended Action Severity Indicates that the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 289
Probable Cause Recommended Action Severity Indicates that specified FRU's state has changed to "inserted". This means that a FRU is inserted but not powered on. No action is required. Verify that the event was planned. INFO FW-1442 Message , [FW-1442], ,, INFO, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 290
may be required to provide adequate power. So (even if the AP blade is powered down or removed) the Switch Status policy values will now reflect the need for 4 power supplies to maintain full (2X) redundancy. No action required, unless there are fewer than 4 power supplies active in the chassis. If - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 291
FW-1500 25 Recommended Action Severity To maintain full (2X) redundancy and proper monitoring by Fabric Watch, 4 active power supplies should be supplied and the default values associated with the presence of an AP blade should be entered with switchstatuspolicyset. WARNING FW-1500 Message < - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 292
25 FW-1501 25-86 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 293
. The severity level can be "critical", "major", or "minor". The active CP will continue to function normally, but because the standby CP is not healthy is not possible. Reboot the standby CP blade by ejecting the card and reseating it. If the problem persists, replace the standby CP. CRITICAL HAM - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 294
that were initiated by the user or the switch errors. The switch reboots can be initiated by the firmwareDownload, fastBoot, haFailover, and reboot commands. Some examples of errors that might initiate this message are hardware errors, software errors, compact flash errors, or memory errors. The - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 295
switch service provider with the supportSave and haDump information. CRITICAL HAMK-1002 Message , [HAMK-1002], ,, INFO, , Heartbeat down Probable Cause Recommended Action Severity Indicates that the active CP blade determined that the standby CP blade - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 296
Heartbeat up Probable Cause Recommended Action Severity Indicates that the active CP blade detects the standby CP blade. This message indicates that the standby CP blade is available to take over in case a failure happens on the active CP blade. This message is typically seen when the standby CP - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 297
() is above threshold. Probable Cause Recommended Action Severity Indicates that the blade voltage is above the threshold. Replace the faulty blade or switch (for nonbladed switches). ERROR HIL-1102 Message , [HIL-1102], ,, ERROR, , Slot - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 298
FRU to verify that they are seated properly. If the problem persists, replace the fan FRU or the power supply FRU as necessary. ERROR HIL-1105 Message , [HIL-1105], ,, ERROR, , Switch error, () above threshold. Probable - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 299
For the SilkWorm 3900, replace the motherboard FRU. For the SilkWorm 4100, if the 12 volt level is faulty, replace one or both power supplies; if any other voltage is faulty, replace the entire switch. ERROR HIL-1107 Message , [HIL-1107], , FFDC, CRITICAL, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 300
is faulty, replace one or both power supplies; if any other voltage is faulty, replace the entire switch. CRITICAL HIL-1201 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 301
. Make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. If the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 302
the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Use - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 303
that a fan FRU has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Replace the affected fan FRU immediately. WARNING HIL-1302 Message , [HIL-1302], ,, WARNING, , - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 304
28 HIL-1303 HIL-1303 Message , [HIL-1303], ,, ERROR, , One fan failed. Replace failed fan FRU immediately. Probable Cause Recommended Action Severity Indicates that a fan FRU has failed. This message is often preceded by a low fan speed message. Replace - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 305
HIL-1306 28 HIL-1306 Message , [HIL-1306], ,, ERROR, , Three fans failed. Replace failed fan FRUs immediately. Probable Cause Recommended Action Severity Indicates that three fan FRUs have failed. This message is often preceded by a low fan speed message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 306
that one or more fans has failed. This message only occurs on the SilkWorm 200E. It follows a previous indication of faultiness. Replace the switch because the fan is not field replaceable. WARNING HIL-1311 Message , [HIL-1311], ,, INFO, , No fans are - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 307
HIL-1401 28 HIL-1401 Message , [HIL-1401], ,, WARNING, , One fan FRU missing. Install fan FRU immediately. Probable Cause Recommended Action Severity Indicates that one fan FRU has been removed. Install the missing fan FRU. WARNING HIL-1402 Message < - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 308
is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Severity . Probable Cause Recommended Action Indicates that the temperature of this blade has risen above the critical threshold. This usually follows a high - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 309
and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the blade. CRITICAL HIL-1503 Message , [HIL-1503], , FFDC, CRITICAL - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 310
sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. WARNING HIL-1506 Message , [HIL-1506], , FFDC, CRITICAL, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 311
fan is not field-replaceable. To help prevent future problems, make sure that the area is well ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. CRITICAL HIL-1509 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 312
To help prevent future problems, make sure that all manual for your switch for the operational temperature range. WARNING HIL-1601 Message , [HIL-1601], ,, ERROR, , Using backup temperature sensor. Service switch. Try rebooting or power cycling the switch. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 313
HIL-1602 28 Severity Run the tempShow command to verify temperature values. If any sensor is too high, monitor the switch. Try rebooting or power cycling the switch. CRITICAL Fabric OS Message Reference Publication Number: 53-1000242-01 28-17 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 314
28 HIL-1602 28-18 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 315
>, Incompatible Inactivity timeout from port , correct value Probable Cause Recommended Action Severity Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The Brocade switch will not accept FSPF frames from the remote - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 316
Indicates that the HLO message received was invalid and the frame was dropped. The Brocade switch will not accept FSPF frames from the remote switch. The switch has received an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 317
. Run the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. CRITICAL Fabric OS Message Reference Publication Number - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 318
30 HMON-1001 30-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 319
>, [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Recommended . For more information on PID, format refer to the Fabric OS Administrator's Guide. INFO HTTP-1002 Message , [HTTP-1002], , AUDIT, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 320
31 HTTP-1003 Probable Cause Recommended Action Severity Indicates an error in completing the zoning transaction. Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 321
IBPD System Messages Chapter 32 IBPD-1001 Message , [IBPD-1001], ,, WARNING, < character limit [] Probable Indicates that the target name length exceeds the supported limit. Cause Recommended Redo the discovery to get the latest target list, and - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 322
sessions exceed the maximum limit at slot port ge Probable Cause Recommended Action Severity Indicates that the iSCSI login sessions exceed the supported limit per port. Use another port to login. WARNING 32-2 Fabric OS Message Reference Publication Number: 53-1000242 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 323
power cycle the switch. ERROR ICPD-1002 Message , [ICPD-1002], ,, ERROR, , Failed to initialize rc = . Probable Cause Recommended Action Severity Indicates that an initialization of a module within the ICPD failed. Download a new firmware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 324
command. WARNING ICPD-1006 Message , [ICPD-1006], ,, INFO, , iSCSI service is on the switch. Probable Indicates that the iSCSI service is enabled or disabled on the switch. Cause 33-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 325
Message , [ICPD-1007], ,, INFO, , iSNSC service is on the switch. Probable Cause Recommended Action Severity Indicates that the iSNSC service is enabled or disabled on the switch. No action is required. INFO ICPD-1008 Message , [ICPD - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 326
33 ICPD-1008 33-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 327
switch. WARNING IPS-1002 Message , [IPS-1002], ,, ERROR, , Failed to initialize rc = Probable Cause Recommended Action Severity Indicates that an initialization of a module within the IPS daemon failed. Download a new firmware version - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 328
This might be a transient problem. If the message persists, check the memory usage on the switch, using the memShow command. If switch service provider. WARNING IPS-1004 Message , [IPS-1004], ,, WARNING, , Port Config Mode Mismatch slot () port(ge - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 329
IPS-1006 34 Probable Cause Recommended Action Severity Indicates that tunnel setup failed due to a configuration mismatch between the two ends. Reasons for such a mismatch could be the Compression, SACK, FastWrite, and TapePipelining setting. Change the tunnel configuration on one side of the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 330
34 IPS-1006 34-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 331
[ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Indicates that specified port has crashed. Cause Recommended No action is required; the port will restart automatically. Action Severity ERROR Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 332
35 ISCS-1000 35-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 333
, [ISNS-1002], ,, INFO, , Start peering with external iSNS server slot/port /. Probable Indicates that peering has started with the specified external iSNS server. Cause Recommended No action is required - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 334
[ISNS-1005], ,, INFO, , User request re-register with external iSNS server slot/port /. Probable Indicates that the user has requested a re-register with the specified external iSNS server. Cause Recommended No action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 335
[ISNS-1006], ,, INFO, , Start re-register with external iSNS server slot/port /. Probable Cause Recommended Action Severity Indicates that the re-register with the specified external iSNS server has started. No action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 336
is out of range. Retry with a valid slot/port. Refer to the appropriate hardware reference manual for valid slot and port ranges. WARNING ISNS-1011 Message , [ISNS-1011], ,, INFO, , iSNS Client Service is . Probable - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 337
created. If a core file is found, FTP all core files to a secure server location. Copy the warning message, any core file information, and contact your switch service provider. WARNING Fabric OS Message Reference Publication Number: 53-1000242-01 37-1 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 338
37 KSWD-1003 37-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 339
38 KTRC-1001 Message , [KTRC-1001], ,, WARNING, , Dump memory size exceeds dump file size Probable Indicates that the dump memory size has exceeded the dump file size. Cause Recommended No action is required. Action Severity WARNING KTRC-1002 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 340
38 KTRC-1004 Probable Cause Recommended Action Severity Indicates that the ATA dump driver is not initialized properly. No action is required. ERROR KTRC-1004 Message , [KTRC-1004], ,, ERROR, , Cannot write to ATA dump - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 341
on bladed switches. Run the saveCore command to FTP core files to a server location. It is normal behavior if there are no core files to transfer. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 342
on bladed switches. Run the saveCore command to FTP core files to a server location. It is normal behavior if there are no core files to transfer. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 343
valid link state ID is the same as the valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended No action is required. Action Severity ERROR LSDB-1002 Message , [LSDB-1002], ,, INFO, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 344
Probable Cause Recommended Action Severity Indicates that there is no local link state record entry in the link state database. The switch should always generate its own local entry when starting up. An "incarnation" is a progressive number that identifies the most recent version of - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 345
). If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR MFIC-1002 Message , [MFIC-1002], ,, INFO, , Chassis FRU header not programmed for - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 346
state> Probable Cause Recommended Action Severity Indicates that one or more switches joined the fabric with a different insistent domain ID (IDID) mode or "Off". IDID mode is a fabric-wide mode; make sure that any switches added to the fabric are configured with the same IDID mode as the fabric. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 347
MPTH System Messages Chapter 42 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = Probable Indicates that a null parent was reported. MPATH uses a tree structure in which the parent is used to Cause connect to the root of the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 348
42 MPTH-1003 Recommended Action Severity No action is required. WARNING 42-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 349
• 7 - MSG_LINIT_IU • 8 - MSG_RSCN • 9 - MSG_IOCTL • 10 - MSG_ACCEPT • 11 - MSG_IU_FREE • 12 - MSG_US • 13 - MSG_EXT_RSCN • 14 - MSG_RDTS_START • 15 - MSG_RDTS_SENDEFP • 16 - MSG_RDTS_RESET Recommended No action is required. Action Severity ERROR Fabric OS Message Reference Publication Number: 53 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 350
43 MQ-1004 43-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 351
. Recommended Action: Set the flag for the MS Platform Service. • The GCAP (MS Get Capabilities) is not supported by another switch. Recommended Action: Upgrade the firmware level on the switch to a level that supports RCS. • The request to the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 352
. • Set the flag for the MS Platform Service. • Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater. • - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 353
IU size might be inconsistent with each other or with the command that is currently being processed. Wait a few minutes and try the operation again. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 354
FTP transfers; then run the supportSave command and contact your switch service provider. ERROR MS-1022 Message , [MS-1022], ,, INFO, , Management Server Platform Service Probable Cause Recommended Action Severity Indicates that - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 355
Probable Cause Recommended Action Severity Indicates that Management Server Topology Discovery Service is being enabled or disabled. No action is required. INFO MS-1024 Message , [MS-1024], ,, INFO, , Management Server Access Control - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 356
44 MS-1024 44-6 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 357
• 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full Recommended No action is required. Action Severity INFO NBFS-1002 Message , [NBFS to neighbor FSM, state , port Probable Cause Indicates that the wrong input was sent to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 358
If this error occurs repeatedly, it means the protocol implementation between two connected switches has problems. Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is FULL, then this message can safely be ignored. Otherwise, run the portDisable and - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 359
that the response payload exceeds the maximum frame size that the remote switch can handle. Run the firmwareDownload command to upgrade the remote switch with firmware v4.3 or higher, or v3.2 or higher, as appropriate for the switch type, so that it can support GMI to handle frame fragmentation and - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 360
Recommended Action Severity Indicates that the name server on the standby CP has lower supported capability than the active CP due to different firmware versions running on the active and standby CPs. This means that the active and standby CPs are out of sync. Any execution of the haFailover or - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 361
during the installation. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1002 Message , [PDM-1002 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 362
the PDM process. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1004 Message , [PDM-1004], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 363
many entries. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1007 Message , [PDM-1007], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 364
setCfg failed. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1010 Message , [PDM-1010], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 365
conf is empty. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1014 Message , [PDM-1014], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 366
firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service -number>,, WARNING, , Failed to download area port map 47-6 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 367
call failed. Run the firmwareDownload command to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING Fabric OS Message Reference Publication Number: 53 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 368
47 PDM-1021 47-8 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 369
PDTR System Messages Chapter 48 PDTR-1001 Message , [PDTR-1001], ,, INFO, , < informational message > Probable Cause Recommended Action view the panic dump and core dump files. INFO Fabric OS Message Reference Publication Number: 53-1000242-01 48-1 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 370
48 PDTR-1002 48-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 371
FTP transfers; then run the supportSave command and contact your switch service provider. CRITICAL PLAT-1001 Message , [PLAT-1001], is typically generated by a CP that is in the process of becoming the active CP. Note that in certain circumstances a CP may experience a double reset and - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 372
49 PLAT-1001 49-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 373
Link Failures Probable Cause Recommended Action Severity Indicates that the specified port is now disabled because the link on this port had multiple failures that exceed an internally set threshold on the port. This problem is typically related to hardware. Check and replace (if necessary) the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 374
configuration. Probable Cause Recommended Action Severity Indicates that the specified port is configured to be an L_port, but that port does not support L_port. If an L_port is connected, then the port will be disabled because it does not support L_port. If an E_port or F_port is connected then - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 375
software error has occurred in Advanced Performance Monitoring. The Performance Monitor has failed to initialize. The CP should reboot (or fail over) automatically. If it does not, reboot or power cycle the switch to reinitiate the firmware Fabric OS Administrator's Guide for more information about - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 376
Indicates that an unexpected software error has occurred in Monitoring, but other functions should function normally. To retry activating tracing, reboot (or fail over) the CP. INFO at least one ISL port. No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 377
PS-1005 51 Recommended Action Severity To resume counting, delete some end-to-end monitors sharing the same hardware resource pool. WARNING Fabric OS Message Reference Publication Number: 53-1000242-01 51-3 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 378
51 PS-1005 51-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 379
is required. INFO PSWP-1002 Message , [PSWP-1002], ,, INFO, , Port Swap feature enabled Probable Indicates that the portSwap feature has been enabled in the switch. Cause Recommended No action is required. Action Severity INFO Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 380
-1003 Message , [PSWP-1003], ,, INFO, , Port Swap feature disabled Probable Cause Recommended Action Severity Indicates that the portSwap feature has been disabled in the switch. No action is required. INFO 52-2 Fabric OS Message Reference Publication - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 381
> MB) was reached. Probable Cause Recommended Action Severity Indicates that the maximum storage size for FFDC data capture is reached. Run the supportSave command and contact your switch service provider. WARNING RAS-1003 Message , [RAS-1003], ,, WARNING, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 382
, [RAS-1005], , FFDC, WARNING, , Software 'assert' error detected. Probable Indicates a internal software error. Cause Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING 53-2 Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 383
in Fabric OS v2.6, v3.1 and greater, v4.1 and greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. INFO RCS-1002 Message , [RCS-1002], ,, INFO, , RCS has been enabled. Probable Cause Recommended - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 384
command. Check memory usage on the switch using the memShow command. Reboot or power cycle the switch. ERROR RCS-1004 Message , greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message , - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 385
remote domain rejected an RCS phase initiated by an application on the local switch. If the reject phase is ACA, the remote domain might be busy and size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 386
ERROR, , Domain Lowest Max Zone DB size Probable Cause Recommended Action Severity Indicates that the specified domain has the lowest maximum Zone database size. Reduce the zone database size. ERROR 54-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 387
Action Severity Indicates that an SSL certificate is missing. To enable RPCD in Secure mode, install a valid SSL certificate on the switch. WARNING RPCD-1003 Message , [RPCD-1003], ,, WARNING, , Permission denied accessing certificate file. Secure RPCd is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 388
, , Permission denied accessing private key file. Secure RPCd is disabled. Probable Indicates that the private key file configured on the switch could not be accessed because root did not Cause have read-level access. 55-2 Fabric OS Message Reference Publication Number: 53-1000242 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 389
RPCD-1007 55 Recommended Action Severity Change the file system access level for the private key file and make sure that root has read-level access. WARNING RPCD-1007 Message , [RPCD-1007], ,, WARNING, , Invalid private file. Secure RPCd is disabled. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 390
55 RPCD-1007 55-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 391
the maximum number of retries sending data to the specified domain. Possible detail values include: • RTWRTransmit: Max retries exhausted • detail1: Port • detail2: Domain • detail3: Retry Count • detail4: Status • detail5: Process ID Run the fabricShow command to see if the specified domain - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 392
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING RTWR-1003 Message , [RTWR-1003], ,, INFO, , : RTWR retry - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 393
has failed because the SCN queue for the specified daemon name is full. This might be caused by the daemon hanging or if the a hung daemon, the software watchdog will cause the daemon to dump the core and reboot the switch. In this case, run switch service provider. CRITICAL Fabric OS Message Reference Publication - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 394
57 SCN-1001 57-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 395
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR SEC-1002 Message , [SEC-1002], ,, ERROR, , Security data fails: Probable Cause - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 396
database download. Reset the version stamp on the switch to 0 using the secVersionReset command and then rejoin the switch to the fabric. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 397
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING SEC-1007 Message , [SEC-1007], ,, INFO, , Security violation: Unauthorized host with IP - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 398
all PKI objects exist on the switch. If the private key does not exist, follow objects, outlined in the Secure Fabric OS Administrator's Guide. If a certificate does not exist or is Indicates that the size of the security database is too large for the flash memory. The size of the security - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 399
occurred during the distribution of the security database. This can occur only when the primary FCS distributes the security database to the other switches in the fabric, then local validation finds the error in the security database. This is a rare occurrence. Run the secFabricShow command to - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 400
the error state, the database might not be correctly updated for that specific switch. ERROR SEC-1031 Message , [SEC-1031], ,, WARNING, , Current security policy DB cannot be supported by standby. CPs will go out of sync. 58-6 Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 401
Indicates that the security database size is not supported by the standby CP. Reduce the security database size by reducing the number of entries as the asterisk symbol). Only valid switch identifiers, that is WWN, domain ID or switch name are supported for the member parameter. The asterisk - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 402
58 SEC-1034 SEC-1034 Message , [SEC-1034], ,, ERROR, , Invalid member . Probable Cause Recommended Action Severity Indicates that the input list has an invalid member. Verify the member names, and input the correct information. ERROR SEC- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 403
list had an invalid format. Run the command again using the standard WWN format, 16 hexadecimal digits grouped as eight colon separated pairs. For example: 50:06:04:81: that the port list contains the wildcard asterisk (*) character. You cannot use the asterisk in a port list. Enter the port list - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 404
58 SEC-1041 SEC-1041 Message , [SEC-1041], ,, ERROR, , Invalid port member in portlist (). . Probable Cause Indicates that the port member is invalid for one of the following reasons: • The value is not a number. • The - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 405
SEC-1045], ,, ERROR, , Too many port members. Probable Cause Recommended Action Severity Indicates that there has been a when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 406
the error state, the database might not be correctly updated for that specific switch. ERROR SEC-1051 Message , [SEC-1051], ,, ERROR, , Missing brace for port list . Probable Cause Recommended Action Indicates that there has been a corruption - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 407
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 408
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 409
occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in either that no domains or domains more than the maximum number supported are specified. Cause Recommended Enter the correct number of domains. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 410
sign message. Probable Cause Recommended Action Severity Indicates that the PKI objects on the switch are not in a valid state and the signature operation failed. Run the pkiShow database is corrupted for unknown reasons. Cause 58-16 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 411
First change some policy definitions, then run the secPolicyActivate command to activate the policies. ERROR SEC-1072 Message , [SEC-1072 automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR SEC-1073 Message , [SEC-1073], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 412
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 413
Cause Recommended Action Severity Indicates that the policy could not be activated. Possible reasons that the policy could not be activate include not enough memory or a busy switch. Run the secFabricShow command to verify that all switches in the fabric are in the ready state. Retry the command - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 414
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 415
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 416
the security database has more data than can be distributed to some of the switches in the fabric. Reduce the number of entries in the security policies to decrease the security database size. ERROR SEC-1088 Message , [SEC-1088], ,, ERROR, , Cannot execute - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 417
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 418
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 419
[SEC-1097], ,, ERROR, , Cannot find policy set. Probable Cause Recommended Action Severity Indicates that the the supportSave command and contact your switch service provider. ERROR Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 420
system-name>, No FCS list. Probable Cause Recommended Action Severity Indicates that the specified policy could not be found. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR SEC-1099 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 421
>, [SEC-1102], ,, ERROR, , Fail to download . Probable Cause Recommended Action Severity Indicates that the switch failed to download certificate, security database, or policies. This can happen when switch does not get enough resources to complete the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 422
for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide. Severity ERROR SEC-1107 Message , [SEC-1107], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 423
the secFabricShow command to verify that all switches in the fabric are in the ready state. When all switches are in the ready state, retry with current active FCS list. Fail to download defined database. Probable Cause Recommended Action Severity Indicates that the defined and active FCS policy - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 424
>, FCS list must be the first entry in the Active Security policies, and the same as the current active FCS list in the switch. Probable Cause Recommended Action Severity Indicates that either a security policy download is attempted with an active policy that does not have the FCS policy as the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 425
. When all switches are in the ready state, retry the operation. INFO SEC-1118 Message , [SEC-1118], ,, INFO, , Fail to set SNMP string. Probable Cause Recommended Action Severity Indicates that the SNMP string could not be set. Usually this problem is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 426
on the switch is not synchronized of the switches in the switches in fabric are in the ready state. When all Action switches are in the ready state, retry the operation. Severity INFO SEC-1123 Message , [SEC-1123], ,, INFO, , Security database downloaded - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 427
INFO SEC-1130 Message , [SEC-1130], ,, INFO, , The Primary FCS has failed over to a new switch. Probable Cause Recommended Action Severity Indicates that an FCS failover operation was completed successfully. Verify that the security event was planned. If - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 428
the security database sending from the primary FCS switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service, or the signature verification failed. Signature verification failure - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 429
Indicates that a non-primary FCS switch received a security database download. Verify that the security event was switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 430
Probable Cause Recommended Action Severity Indicates that the PID format of the switch was changed either to extended-edge PID or from extendededge PID. If DCC polices existed, all index/area ID values either increased or decreased by 16. The values wrap around after 128. If a DCC policy contains an - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 431
support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 432
size of the specified policy database. INFO SEC-1156 Message , [SEC-1156], ,, INFO, , Change failed: - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 433
the error state, the database might not be correctly updated for that specific switch. INFO SEC-1160 Message , [SEC-1160], ,, INFO, , Duplicate port in port list (). Probable Cause Recommended Action Severity Indicates that duplicate - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 434
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 435
. Verify that the security event was planned. If the security event was planned, retry FCS failover after current failover has completed, if this switch should become primary FCS. If the security event was not planned, take appropriate action as defined by your enterprise security policy. ERROR SEC - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 436
all PKI objects exist. If they do not exit, run the pkiCreate command to create them for the switch. Run the licenseAdd command to install the required license key. Refer to your switch supplier to obtain a license if you do not have one. ERROR SEC-1172 Message , [SEC-1172], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 437
name>, Failed to install zone data. Probable Cause Recommended Action Severity Indicates that the zone database could not be installed on the switch. Verify that all switches in the fabric are in time synchronization with the primary and that no external entity is trying to access the fabric. When - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 438
58 SEC-1180 SEC-1180 Message , [SEC-1180], ,, INFO, , Added account with authorization. Probable Cause Recommended Action Severity Indicates that the specified new account has been created. No action is required. INFO SEC-1181 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 439
>,, ERROR, , Policy to binary conversion error: Port is out range. Probable Cause Recommended Action Severity Indicates automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR SEC-1184 Message , [SEC-1184], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 440
], ,, INFO, , Security violation: Unauthorized device tries to FLOGI to index/area of switch . Probable Cause Recommended Action Indicates that a DCC security violation was reported. The specified device attempted to login - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 441
SEC-1189 58 Severity INFO SEC-1189 Message , [SEC-1189], ,, INFO, , Security violation: Unauthorized host with IP address tries to do SNMP write operation. Probable Cause Recommended Action Severity Indicates that an SNMP security violation - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 442
IP address is being used by a valid switch admin. Use the correct password. INFO SEC-1194 ,, WARNING, , This switch does not have all the required PKI distributing the security database to the other switches in the fabric and local validation finds that there is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 443
corruption during the distribution of the security database. This can only occur when the primary FCS is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Run the secFabricShow - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 444
SEC-1199 Message , [SEC-1199], ,, INFO, , Security violation: Unauthorized access to serial port of switch . Probable Cause Recommended Action Severity Indicates that a serial connection policy security violation was reported. An attempt - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 445
was reported. An MS device operation occurred on a non-primary FCS switch. Check the management server policy and verify that the connection is allowed. from MS device node name , device port name . Probable Cause Recommended Action Severity Indicates that a MS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 446
message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING SEC-1251 Message , [SEC-1251], ,, ERROR, , Policy to binary conversion error: - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 447
then run the supportSave command and contact your switch service provider. ERROR SEC-1300 Message , [SEC-1300], ,, INFO, , This switch is in VcEncode mode. Security is not supported. Probable Indicates that the switch is set up with VC-encoded mode. Cause - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 448
that the currently installed software version does not support the Brocade Secure Fabric OS feature. Run the firmwareDownload command to update the firmware to the latest version for your specific switch. Verify that the firmware you are installing supports the Brocade Secure Fabric OS feature - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 449
PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS Administrator's Guide. If PKI objects are valid, verify that an unauthorized switch is not trying to access the fabric. INFO SEC-1307 Message , [SEC-1307], ,, INFO, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 450
, Unable to determine data distribution limit of fabric. Please retry later. Probable Unable to obtain the data distribution limit from all switches in the fabric. This may happen if the fabric Cause is reconfiguring or a new domain joined the fabric. Recommended Retry the command when - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 451
to the default value. Verify that the security event was planned. If the security event was planned, run the passwdCfg --setDefault command on each switch in the fabric to set the password policies to the default value. Then verify with passwdCfg --show that passwd policies are set to the defaults - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 452
call to the EM module to retrieve the IP address failed. Please reboot the system to fix this error. If the problem persists contact your switch service provider. ERROR SEC-1315 Message , [SEC-1315], ,, ERROR, , command failed - - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 453
SEC-1317 58 SEC-1317 Message , [SEC-1317], ,, INFO, , Inconsistent fabric, rejecting transaction Probable Cause Recommended Action Severity Indicates that either this domain is performing an FDD merge or matched domains are not the same as what the CM - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 454
Severity Indicates that the security enable failed on the fabric because switch has conflicting configuration such as fabric wide consistency configuration or is not able to support a DCC policy with more than 256 ports. Reconfigure any policy that has more than 256 ports in member list, then - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 455
enterprise security policy. INFO SEC-1325 Message , [SEC-1325], ,, ERROR, , Security enforcement: Switch connecting to port is not authorized to stay in fabric. Probable Cause Recommended Action Severity Indicates that due to an - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 456
Name> policy is conflicting with domain Probable Strict policy is conflicting. Cause Recommended None, the domain is denied by disallowing all its E-ports connected to the fabric. If the domain should Action be allowed to merge with the fabric, then resolve the issue by making the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 457
failed. Probable Cause Recommended Action Severity Indicates that the initialization of the SNMP service failed and you will not be able to query the switch through SNMP. Reboot or power cycle the switch. This will automatically initialize SNMP. ERROR SNMP-1003 Message , [SNMP-1003 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 458
Action Severity Retry changing the SNMP community strings from the primary switch. ERROR SNMP-1004 Message , [SNMP-1004], < Action Severity Indicates that the SNMP configuration is incorrect and the SNMP service will not work correctly. Change the SNMP configuration back to the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 459
Severity INFO SNMP-1006 59 Fabric OS Message Reference Publication Number: 53-1000242-01 59-3 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 460
59 SNMP-1006 59-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 461
host ip>. Probable Indicates that the supportSave command was used to transfer support information to a remote FTP Cause location. Recommended No action is required command to set the FTP parameters. After the FTP problem is corrected, rerun the supportSave command. WARNING Fabric OS Message Reference - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 462
60 SS-1001 60-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 463
. Probable Cause Recommended Action Severity Indicates that the previous standby has now become the active CP and is running the new firmware version. No action is required. The firmwareDownload command is progressing as expected. Run the firmwareDownloadStatus command for more information. INFO - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 464
. Refer to the Fabric OS Administrator's Guide for troubleshooting information. INFO SULB-1022 Message , [SULB-1022], ,, WARNING, , The blade in slot has rebooted successfully with new firmware. 61-2 Fabric OS Message Reference Publication - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 465
the new firmware has been downloaded to the specified AP blade and the AP blade will reboot to active it. Wait for the AP blade to reboot. WARNING SULB-1031 Message , [SULB-1031], ,, WARNING, , The switch is relocating an internal firmware image. Probable - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 466
error can be caused by inconsistent AP blade firmware. It can also be caused by persistent storage hardware failure, or other hardware failures. Try reseating the AP blade. Run firmwareDownload again. If the problem persists, contact your switch service provider. ERROR SULB-1036 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 467
run the supportSave command and contact your switch service provider. ERROR SWCH-1002 Message < port Probable Cause Recommended Action Severity Indicates that the device is not present in the authorized profile list. Verify that the device is authorized to log in to the switch - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 468
slotPowerOn commands. On a SilkWorm 200E, 3250, 3850, 3900, or 4100 switch, reboot or power cycle the switch. ERROR SWCH-1004 Message , [SWCH-1004], ,, ERROR, , Blade attach failed during recovery, disabling slot = Probable Cause Recommended - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 469
NPIV devices logged into the fabric. Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload command. WARNING SWCH-1007 Message , [SWCH-1007], ,, WARNING, , Switch port disabled due to \" - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 470
62 SWCH-1008 Recommended Action Severity Replace the blade with ports that support port swap. Then port swap the ports back to ports default area. Refer to the Fabric OS Administrator's Guide for more information on port swapping. WARNING 62-4 Fabric OS Message Reference Publication Number: 53- - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 471
for one or more programs to register with system services or to fail over to active status. The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before rebooting the chassis, record the firmware version on the switch (or CP) and run the haDump command. If this - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 472
> is not supported by CP Blade with ID . Change that option is not supported on this platform running this version of the firmware. It could also indicate Recommended Use the supportSave command to gather troubleshoot data. No further action is required - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 473
SYSC-1005 63 Recommended Action Severity Use the supportSave command to gather troubleshooting data. Issue a hardboot or hafailover to recover the system and limit the traffic disruption. WARNING Fabric OS Message Reference Publication Number: 53-1000242-01 63-3 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 474
63 SYSC-1005 63-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 475
memory. Run the memShow command to view the switch memory usage. Reboot or power cycle the switch. Run supportFtp and traceFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. CRITICAL SYSM-1002 Message , [SYSM - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 476
64 SYSM-1003 SYSM-1003 Message , [SYSM-1003], ,, INFO, , , Switch: Probable Cause Recommended Action Severity Indicates that the user executed the switchStart or switchReboot command. This indicates that all services CP blade in - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 477
SYSM-1006 64 SYSM-1006 Message , [SYSM-1006], , FFDC, CRITICAL, , CP blade in slot is incompatible with the chassis type. Probable Cause Recommended Action Severity Indicates that this chassis type is not compatible with the CP blade. Use - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 478
64 SYSM-1007 64-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 479
• WATCHDOG EXPIRED generated by hardware watchdog expiration • MANUAL generated by the tracedump -n command Run supportFtp and traceFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING TRCE-1002 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 480
down, or the network being down. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Note: You can also run the traceFtp -e command to enable auto-FTP. ERROR 65-2 Fabric OS Message Reference Publication Number: 53 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 481
synch with other CP. Probable Cause Recommended Action Severity Indicates that the active CP is unable to alert the standby CP of a change in automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR TRCE-1008 Message , [TRCE-1008], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 482
to verify that the current CP is standby and the active CP is active. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR TRCE-1010 Message , [TRCE-1010], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 483
the indicated slot is unavailable. Cause Recommended Check that the AP blade is enabled and retry the command. If the AP blade is already enabled, run the Action supportSave command and contact your switch service provider. Severity WARNING Fabric OS Message Reference Publication Number: 53-1000242 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 484
65 TRCE-1012 65-6 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 485
this message indicates a typing error by an authorized user. If this message occurs repeatedly, it might indicate an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the IP address of a failed login is reported to the error log. INFO TRCK-1003 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 486
change from task: Probable Cause Recommended Action Severity Indicates that the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configDownload. This message is not - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 487
TRCK-1006 66 Recommended Action Severity No action is required. Run the trackChangesSet 1 command to enable the track changes feature. INFO Fabric OS Message Reference Publication Number: 53-1000242-01 66-3 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 488
66 TRCK-1006 66-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 489
be either: • LOCL Local clock on the principal or primary FCS switch • External External NTP server address configured This might be logged during temporary for external time synchronization but the principal or primary FCS does not support the feature. If the message does not recur, it should be - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 490
FCS does not support the feature, either choose a different switch for the role or reset the clock server to LOCL. WARNING TS-1006 Message , [TS-1006], ,, INFO, , Probable Cause Recommended Action Severity Indicates that a time service event is - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 491
>, [UCST-1007], , FFDC, CRITICAL, , Inconsistent route detected: Port = , should be Probable Cause Recommended Action Severity Indicates that the switch detected an inconsistency in the routing database between the routing protocol and the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 492
68 UCST-1020 UCST-1020 Message , [UCST-1020], ,, WARNING, , Static route (input-area: , domain: output-area: ) has been ignored due to platform limitation. Probable Cause Recommended Action Severity Indicates that the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 493
-1001 Message , [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list Probable Indicates that the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists Cause in the candidate list (domain ID list). Recommended No action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 494
69 UPTH-1001 69-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 495
USWD System Messages Chapter 70 USWD-1006 Message , [USWD-1006], ,, WARNING, , uSWD: Probable Indicates a warning state in the system. This is an internal use only message. Cause Recommended No action is required. Action Severity WARNING - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 496
70 USWD-1006 70-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 497
WEBD System Messages Chapter 71 WEBD-1001 Message , [WEBD-1001], ,, WARNING, , Missing or Invalid Certificate file -- HTTPS is configured to be enabled but could not be started. Probable Cause Recommended Action Severity Indicates that the SSL - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 498
, [WEBD-1005], ,, WARNING, , HTTP server will be restarted for logfile truncation Probable Indicates that the size of HTTP logfile exceeded the maximum limit. Cause Recommended No action is required. Action Severity WARNING WEBD-1006 Message - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 499
Probable Cause Recommended Action Severity Indicates that the IP address of the switch changed and the HTTP server is restarted. No action is required. where the builtin recovery process has failed to restore http services. The problem often results from invalid configuration of ssl certs., but - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 500
71 WEBD-1008 71-4 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 501
the saveCore command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. ERROR Fabric OS Message Reference Publication Number: 53-1000242-01 72-1 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 502
72 ZOLB-1001 72-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 503
FTP transfers; then run the supportSave command and contact your switch service provider. WARNING ZONE-1003 Message , [ZONE-1003], ,, WARNING, , zone() contains (, ) which does not exist. Probable Cause Indicates that - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 504
using both WWN in one zone and in another, this will cause that port to go session based hard zoning. In session-based zoning, the zone enforcement is checked by the software. In hardware-enforced zoning, zone or alias members are defined using exclusively or - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 505
the filter setup. There are two ways to avoid this problem. • Avoid having too many hosts zoned with a set of target devices at a single port. • Avoid having too many zones directed at a single port group on the switch. INFO ZONE-1008 Message , [ZONE-1008], ,, WARNING - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 506
-number>,, WARNING, , WARNING - All ports are offline. Probable Indicates that all the ports in a zone are offline. Cause Recommended Check is not supported in the current code release. If the QuickLoop zoning configuration is enabled on the switch, it will not be supported. Edit - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 507
Action Severity Indicates that the required zoning license is missing. Install the zoning license using the licenseAdd command. Refer to your switch supplier to obtain a Zoning license if you do not have one. ERROR ZONE-1015 Message , [ZONE-1015], ,, WARNING - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 508
port. This is a software error. A QuickLoop zone type (value = 4) or an uninitialized type (value = 0) are invalid. The valid zone type values are: • hard port zone (value = 1) • hard wwn zone (value = 2) • session based hard zoning (value = 3) • FA zone (value = 5) QuickLoop zones are not supported - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 509
the merge operation. This usually occurs if the switch on the other side of the port is busy. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. INFO ZONE-1024 Message , [ZONE - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 510
zoning database to have zoned PIDs for that port. INFO ZONE-1027 Message , [ZONE- aborted the current zoning transaction. • Switch Shutting Down: The switch is currently shutting down. Many of the DB larger than supported - greater than 73-8 Fabric - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 511
specific switches in your fabric. Refer to the Fabric OS Administrator's Guide for information on the zone database sizes supported for each switch. FTP transfers; then run the supportSave command and contact your switch service provider. WARNING ZONE-1030 Message , [ZONE-1030], - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 512
switch, port) members not supported. Probable Cause Recommended Action Severity The switch is set to interop mode using the interopMode command. Interop mode does not allow members in the active the zone database being committed. Reduce the size of the zone database and retry the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 513
zone database is not found. Use the firmwareDownload command to reinstall the firmware. WARNING ZONE-1035 Message , [ZONE-1035], ,, is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 514
OS cannot read the zone configuration file. Typically the zone configuration is Cause too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR 73-12 Fabric OS Message Reference Publication Number: 53-1000242 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 515
the zone configuration is too large for the memory available on the switch. Reduce the size of the zone database and retry the operation. INFO ZONE-1041 unstable link or faulty cable. Check the SFP and cable at the specified port and verify that they are not faulty. Replace the SFP and cable as - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 516
73 ZONE-1043 ZONE-1043 Message , [ZONE-1043], ,, INFO, , The Default Zone access mode is set to No Access Probable Cause Recommended Action Severity Indicates that the Default Zone access mode is set to No Access. Verify that this Default Zone access mode - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 517
ZONE-1046 73 ZONE-1046 Message , [ZONE-1046], ,, INFO, , The Default Zone access mode is already set to All Access Probable Cause Recommended Action Severity Indicates that the Default Zone access mode is already set to All Access. No action is required. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 518
73 ZONE-1046 73-16 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 519
Audit Log Messages This section provides the Audit messages, including: • AUDIT AUTH System Messages • AUDIT CONF System Messages • AUDIT HTTP System Messages • AUDIT SEC System Messages • AUDIT SNMP System Messages • AUDIT SULB System Messages • AUDIT ZONE System Messages Section II Fabric OS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 520
II-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 521
AUDIT AUTH System Messages Chapter 74 AUTH-3001 Message AUDIT, , [AUTH-3001], INFO, SECURITY, , , , Event: , Status: success, Info: type has been changed from [] to []. Probable Cause Recommended - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 522
74 AUTH-3003 AUTH-3003 Message AUDIT, , [AUTH-3003], INFO, SECURITY, , , , Event: , Status: success, Info: the PKI objects. Probable Cause Recommended Action Severity Indicates that the pki Objects were created using - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 523
Action Severity The configDownload process was initiated and completed successfully. The message string describes the class of configuration parameters that were downloaded. If AD is enabled, the AD number is specified in the description. No action is required. INFO CONF-1020 Message AUDIT - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 524
Action Severity The system attempted to download a configuration without disabling the switch was unsuccessful because there are one or more parameters that require the switch to be disabled. Disable the switch using the switchDisable command and download the configuration. WARNING 75-2 Fabric OS - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 525
AUDIT HTTP System Messages Chapter 76 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Recommended Action Severity Indicates - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 526
76 HTTP-1003 76-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 527
security event has occurred. The Event Name can be one of the following: • There has been an FCS failover. • A security policy has been activated. • A security policy has been saved. • A security policy has been aborted. • A non-FCS password has changed. Verify that the security event was planned - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 528
77 SEC-3003 SEC-3003 Message AUDIT, , [SEC-3003], INFO, SECURITY, , , , Event: , Status: success, Info: Created policy, with member(s) . Probable Cause Recommended Action Severity Indicates that a new - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 529
SEC-3006 77 Recommended Action Severity Verify that the addition of members to the policy was planned. If the addition of members was planned, no action is required. If the addition of members was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3006 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 530
77 SEC-3008 SEC-3008 Message AUDIT, , [SEC-3008], INFO, SECURITY, , , , Event: , Status: success, Info: FCS member moved from position to . Probable Cause Recommended Action Severity Indicates - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 531
SEC-3011 77 Severity INFO SEC-3011 Message AUDIT, , [SEC-3011], INFO, SECURITY, , , , Event: , Status: success, Info: Reset [] statistics on domain(s) []. Probable Cause Recommended Action Severity Indicates - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 532
, , , , Event: , Status: success, Info: RADIUS server for AAA services. Probable Cause Recommended Action Severity Indicates that a user has changed the RADIUS configuration. Verify that the RADIUS configuration was - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 533
SEC-3017 77 Probable Cause Recommended Action Severity Indicates that a user has changed the specified attribute of the RADIUS server. Verify that the RADIUS attribute was intentionally changed. If the RADIUS attribute was intentionally changed, no action is required. If the RADIUS attribute was - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 534
77 SEC-3019 SEC-3019 Message AUDIT, , [SEC-3019], INFO, SECURITY, , , , Event: , Status: success, Info: Passwdcfg parameters set to default values. Probable Cause Recommended Action Severity Indicates that the passwdCfg parameters - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 535
, the account has been locked. The Account may automatically unlock after the lockout duration has expired or an administrator may manually unlock the account. INFO SEC-3024 Message AUDIT, , [SEC-3024], INFO, SECURITY, , , , Event: - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 536
77 SEC-3025 SEC-3025 Message AUDIT, , [SEC-3025], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] added. Role: [], Password [], Home AD [], AD list [ - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 537
SEC-3028 77 Severity INFO SEC-3028 Message AUDIT, , [SEC-3028], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] deleted. Probable Cause Recommended Action Severity Indicates that the specified user - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 538
3032 Message AUDIT, , [SEC-3032], INFO, SECURITY, , , , Event: , Status: success, Info: Switch is configured to database. Probable Cause Recommended Action Severity Indicates that the specified event - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 539
SEC-3034 77 Recommended Action Severity Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3034 Message AUDIT, , [SEC-3034], INFO, SECURITY, - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 540
77 SEC-3034 77-14 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 541
AUDIT SNMP System Messages Chapter 78 SNMP-1005 Message AUDIT, , [SNMP-1005], INFO, CONFIGURATION, , , , SNMP configuration attribute, , has changed from to Probable Cause Recommended Action Severity - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 542
78 SNMP-1006 78-2 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 543
command to continue without disruption. Do not fail over or power down the system during firmware upgrade. Run the firmwareDownloadStatus command for more information. WARNING that the firmwareDownload command has completed successfully and switch firmware has been updated. No action is required. - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 544
INFO SULB-1009 Message AUDIT, , [SULB-1009], INFO, FIRMWARE, , , , Firmwaredownload command failed. status because FABRIC OS is disabled on Active CP." "Sanity check failed because HAMD is disabled on Active CP." "Sanity check failed because - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 545
failed to reboot and was not responding." 0x58 "Unable to check the firmware version on Standby CP due to IPC error." 0x59 "Sanity check failed System Error." 0x63 "Active CP forced failover succeeded. Now this CP becomes Active." 0x64 "Standby CP booted up." 0x65 "Active and Standby CP - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 546
CP." "firmwareCommit has completed successfully on Standby CP." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareCommit has started on both Active and Standby CPs." "firmwareCommit has completed successfully on both CPs." "firmwareCommit failed on - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 547
be started 0xa2 to recover the blade." "Blade rebooted during firmwareCommit. The operation will be restarted." 0xa3 "Firmware has been downloaded successfully. Blade is rebooting with the new 0xa4 firmware." "Blade has rebooted successfully." 0xa5 "New firmware failed to boot up. Please retry - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 548
list file. Check whether the switch is supported by the requested firmware. Also check firmwaredownload help page for other possible failure reasons." "The RPM package database is inconsistent. Contact your service provider for recovery." "Out of memory." "Failed to download RPM package." 0x12 0x13 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 549
"Cannot download 5.1 because Device Based Routing policy is not supported by 5.1. 0x2d Use aptPolicy to change the routing policy before proceeding." "Invalid RPM package. Please reload firmware packages on the file server." 0x2e "Cannot downgrade due to presence of blade type 17. Remove or power - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 550
issues. If the problem persists, contact your power off the unsupported blades before proceeding. This can also be caused by an invalid chassisConfig option setting. In that case, reset the chassisConfig option before retrying firmwareDownload. 0x2e - Invalid RPM package. Please reload firmware - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 551
firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting blade. The error can be caused by inconsistent AP blade firmware stored on the active - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 552
to remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. ERROR SULB-1020 Message AUDIT, , [SULB-1020], ERROR, FIRMWARE, , , , New firmware failed to boot in slot - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 553
version is still inconsistent with the active CP firmware, firmwaredownload will be started automatically to the blade again. Continue to run the firmwareDownloadStatus command to monitor the progress. However, if this problem persists, contact the service provider for further actions. WARNING SULB - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 554
persistent storage hardware failure, or a software error. firmwareDownload process will continue after the switch is rebooted. So continue to run the firmwareDownloadStatus command to monitor the progress. However, if this problem persists, contact the service provider for further actions. WARNING - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 555
command, for example, power the switch on an off in the middle of a firmwareDownload. This error can also be caused by the persistent storage failure, or other hardware failures. Recommended Retry the firmwareDownload operation. If the problem persists, contact your switch service provider. Action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 556
79 SULB-1034 79-14 Fabric OS Message Reference Publication Number: 53-1000242-01 - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 557
AUDIT ZONE System Messages Chapter 80 ZONE-3001 Message AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \" - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 558
80 ZONE-3003 ZONE-3003 Message AUDIT, , [ZONE-3003], INFO, ZONE, , , , Event: , Status: success, Info: \"\" deleted. Probable Cause Recommended Action Severity Indicates that the specified zone - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 559
ZONE-3006 80 Recommended Action Severity Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO ZONE-3006 Message AUDIT, , [ZONE-3006], INFO, ZONE, < - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 560
80 ZONE-3009 Recommended Action Severity Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO ZONE-3009 Message AUDIT, , [ZONE-3009], INFO, ZONE, < - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 561
, , Event: , Status: success, Info: has been activated. Probable Cause Recommended Action Severity Indicates that the specified Admin doman has been activated. Verify that the event was planned. If the event was planned, no action is required. If the - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 562
80 ZONE-3015 Probable Cause Recommended Action Severity Indicates that the specified new AD object member or members have been added to the specified AD object set. An AD object set type is "AD member". The string "..." appears at the end of the AD object member list if the list was truncated in - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 563
ZONE-3017 80 ZONE-3017 Message AUDIT, , [ZONE-3017], INFO, FABRIC, , , , Event: , Status: success, Info: \"\" created with \"\". Probable Cause Recommended Action - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 564
80 ZONE-3020 Severity INFO ZONE-3020 Message AUDIT, , [ZONE-3020], INFO, FABRIC, , , , Event: , Status: success, Info: \"\" removed from \"\". Probable Cause Recommended - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 565
ZONE-3023 80 Severity INFO ZONE-3023 Message AUDIT, , [ZONE-3023], INFO, FABRIC, , , , Event: , Status: Failure, Info: AD Apply operation failed due to transaction conflict. Probable Cause Recommended Action Severity Indicates that - HP StorageWorks 2/32 | Brocade Fabric OS Message Reference Guide (53-1000242-01, - Page 566
80 ZONE-3025 80-10 Fabric OS Message Reference Publication Number: 53-1000242-01
Publication Number: 53-1000242-01
Publication Date:
09/29/06
Fabric OS
Message Reference
Supporting Fabric OS v5.2.0