HP StorageWorks 4/64 Brocade Fabric OS Command Reference Manual - Supporting F
HP StorageWorks 4/64 - SAN Switch Manual
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 4/64 manual content summary:
- HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 1
53-1000436-01 15 Jun 2007 Fabric OS Command Reference Manual Supporting Fabric OS v5.3.0 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 2
service names are or may be trademarks or service marks of, and are used to identify, products or services for its use. The authors and Brocade Communications Systems, Inc., shall have no liability or responsibility to visit http:// www.brocade.com/support/oscd. Export of technical data contained - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 3
Fabric OS Command Reference 53-0000519-09 Manual September 1999 May 2000 December 2000 July 2001 December 2001 March 2002 September 2002 April 2003 April 2003 May 2003 July 2003 August 2003 October 2003 Excluding edits and commands updated to support the SilkWorm 3250, 3850, and 24000 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 4
Manual Summary of Changes Publication Date Add 8, modify 164, and delete 5 commands. Add switchAdmin and MUA information to chapter 1. Modify chapter 5 from "Commands Unique to Fabric OS v4.x" to "MUA-Based ," content to Structured FrameMaker format to support XML delivery of command content (due - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 5
Supported Hardware and Software xvi What's New in This Document xvii Document Conventions xxi Additional Information xxii Getting Technical Help xxvi Document Feedback xxvii Chapter 1 Using Fabric OS Commands Understanding Role-Based 46 Fabric OS Command Reference Manual i 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 6
chipRegShow 83 cmemRetentionTest 84 cmiTest 86 configDefault 88 configDownload 90 configShow 94 configUpload 97 configure 100 crossPortTest 107 dataTypeShow 110 ii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 7
141 dnsConfig 142 enclosureShow 143 errClear 145 errDelimiterSet 146 errDump 147 errFilterSet 148 errModuleShow 149 errShow 150 exit 151 fabPortShow 152 Fabric OS Command Reference Manual iii 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 8
fcpProbeShow 191 fcpRlsShow 192 fcrbcastconfig 193 fcrChipTest 194 fcrConfigure 196 fcrDisable 197 fcrEnable 198 fcrFabricShow 199 fcrLsanCount 200 fcrLsanMatrix 201 iv Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 9
253 fwAlarmsFilterShow 254 fwClassInit 255 fwConfigReload 256 fwConfigure 257 fwFruCfg 261 fwHelp 262 fwMailCfg 263 fwPortDetailShow 265 fwSamShow 268 fwSet 269 Fabric OS Command Reference Manual v 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 10
iscsiCfg 311 iscsiChipTest 319 iscsiHelp 320 iscsiPathTest 322 iscsiPortCfg 323 iscsiSessionCfg 326 iscsiswcfg 328 iscsiTargetName 330 islShow 331 isnscCfg 332 vi Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 11
372 myId 373 nbrStateShow 374 nbrStatsClear 375 nodeFind 377 nsAliasShow 379 nsAllShow 382 nscamShow 383 nsShow 385 nsZoneMember 388 passwd 391 Fabric OS Command Reference Manual vii 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 12
pkiRemove 439 pkiShow 440 policy 441 portAlpaShow 444 portBufferShow 445 portCamShow 447 portCfg 449 portCfgDefault 455 portCfgEPort 456 portCfgEXPort 457 viii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 13
499 portLogPdisc 500 portLogReset 501 portLogResize 502 portLogShow 503 portLogShowPort 508 portLogTypeDisable 509 portLogTypeEnable 510 portLoopbackTest 511 portMirror 514 portName 517 Fabric OS Command Reference Manual ix 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 14
563 secHelp 565 secModeDisable 566 secModeEnable 567 secModeShow 572 secNonFCSPasswd 573 secPolicyAbort 574 secPolicyActivate 575 secPolicyAdd 576 secPolicyCreate 579 secPolicyDelete 582 x Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 15
620 slotShow 621 slTest 623 snmpConfig 625 snmpMibCapSet 631 snmpMibCapShow 633 spinFab 635 spinJitter 638 spinSilk 641 sramRetentionTest 645 statsClear 647 Fabric OS Command Reference Manual xi 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 16
syslogdIpRemove 691 syslogdIpShow 692 sysShutdown 693 systemVerification 695 tempShow 697 timeout 698 topologyShow 699 traceDump 701 trackChangesHelp 702 trackChangesSet 703 xii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 17
Advanced Performance Monitoring Commands 746 Secure Fabric OS Commands 747 Exclusive Primary FCS Commands Commands Exclusive to the Primary FCS 749 Fabric OS Command Reference Manual xiii 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 18
Control Processor Commands Commands Supported on the Standby CP 753 Chapter 6 supportShow Reference supportShow Control Commands 755 supportShow Command Groups 756 Proc Entry Information Displayed 758 Appendix A RBAC Command Availability xiv Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 19
manual written to help system administrators and technicians operate, maintain, and troubleshoot SAN products. "About This Document" contains the following sections: • "How This Document Is Organized," next • "Supported RBAC Command Availability,"explains the Role-Based Access Control checks used to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 20
here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for Fabric OS v5.3.0, documenting all possible - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 21
What's New in This Document • New commands that were added since this document was last released: - ipfilter - iscsiswcfg - fastwritecfg - fcrLsanCount - fcrLsanMatrix Fabric OS Command Reference Manual xvii 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 22
- firmwareDownloadStatus - firmwareRestore - firmwareShow - fwPortDetailShow - ipAddrSet - ipAddrShow - isnscCfg - licensePort - lsanZoneShow - iscsiCfg - iscsiswcfg - myId - passwd - passwdCfg - perfAddIPMonitor - perfAddRWMonitor xviii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 23
- syslogdIpRemove - syslogdIpShow - traceDump - tsClockServer - userConfig NOTE: FOS v5.3.0. supports the TCP/IP netstat command. Use this command to show network status, print of all netstat options, refer to the Linux man pages. Fabric OS Command Reference Manual xix 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 24
• Information that was deleted or deprecated since this document was last released: - savecore - traceftp - iscsitargetname - fcrdisable - fcrenable - crossporttest xx Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 25
in the narrative portions of this guide are presented in mixed lettercase: for all lowercase. If there are exceptions, this manual specifically notes those cases in which a command is definitions of SAN-specific terms, visit the Storage Networking Industry Association online dictionary at http://www - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 26
Fabric OS Optional Features • Web Tools Administrator's Guide • Fabric Watch Administrator's Guide • Fabric Manager Administrator's Guide • Web Tools EZ Administrator's Guide Brocade 48000 • Brocade 48000 Hardware Reference Manual • Brocade 48000 QuickStart Guide Brocade 24000 • Brocade 24000 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 27
Brocade 7600 • Brocade 7600 Hardware Reference Manual • Brocade 7600 QuickStart Guide Brocade 7500 • Brocade 7500 Hardware Reference Manual • Brocade 7500 QuickStart Guide • Brocade 7500 Fan Assembly Replacement Procedure • Brocade Mid Sized Power Supply Replacement Procedure Brocade Access Gateway - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 28
Manual (for v4.x software) • Brocade 3250/3850 QuickStart Guide (for v4.x software) Brocade 200E • Brocade 200E Hardware Reference Manual Fabrics Supports the reliable based on thresholds set for a variety of SAN fabric elements and events-automatically alerting administrators to potential problems - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 29
FICON® CUP FCIP Tunneling Enables IBM host-based management programs to manage FICON fabric switches in-band by sending commands to the Fabric OS emulated control device. The optional Fibre Channel over Internet protocol (FCIP) Tunneling Service enables Fibre Channel frames to "tunnel" through IP - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 30
Information - Technical Support contract number, if applicable - Switch model - Switch operating system version - Error numbers and messages received - supportSave command output - Detailed description of the problem and specific questions - Description of any troubleshooting steps already performed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 31
and as much detail as possible about your issue, including the topic heading and page number and your suggestions for improvement. Fabric OS Command Reference Manual xxvii 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 32
xxviii Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 33
and management procedures. Understanding Role-Based Access Control Fabric OS v5.3.0 implements Role-Based Access Control (RBAC) to control access to all Fabric OS operations. Seven roles are supported, as defined in Table 1. Role definitions are guided by perceived common operational situations - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 34
manual. Access is controlled by a switch-level password for each access level. The commands available through the CLI are based tool for Brocade SANs, providing: • Access to the full range of Fabric OS features, based switch licenses The remainder of this guide describes each command, including a - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 35
configuration applies to all switch instances in a platform supporting multiple switch domains. Customers can use centralized RADIUS servers to manage AAA services for a switch, as defined in RFC 2865. switch-local database authentication. Fabric OS Command Reference Manual 3 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 36
switch-local database as the primary AAA service. --radiusonly Enables the current RADIUS configuration for AAA services. Use this to select the RADIUS configuration as the primary AAA service. To enable a RADIUS configuration, at least one server must exist in the configuration. --radiuslocal - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 37
aaaConfig 2 Primary AAA Service: Switch database Secondary AAA Service: None To change the configuration for server 192.168.233.48: switch:admin> aaaconfig --change 192.168.233.48 -p 3002 -s newsecret -t 1 See Also none Fabric OS Command Reference Manual 5 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 38
transaction buffer are sent to all other switches and saved to the Defined configuration (in persistent storage). For --apply, it performs a save operation, sends a request to apply the Admin Domain :admin> defzone --noaccess switch:admin> cfgsave 6 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 39
for example, D,[0-34]. The port index range is expanded and stored internally. Same D,PI members can be specified in more than one Admin Domain. Device WWN Uses traditional zone WWN member types. Benefits include: Supports node or port WWNs. Fabric OS Command Reference Manual 7 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 40
entry in the switch list with a semicolon (;). Specify the switch in one of the following formats: Switch WWN Domain ID Any switch member specified Domain ID format will be converted into a switch WWN based on the current fabric information. Operations with switch list will Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 41
a new shell. ad --select to the specified Admin Domain. Execute the commands. Exit out of the shell. --remove ad_id -d "dev_list"-s "switch_list" Removes one or more members from an Admin Domain. Removing the last member element in the Admin Domain deletes the Admin Domain. The remove operation - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 42
-Admin Domain aware switches and members that are not online are marked with a B or an asterisk B at the end, respectively. 10 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 43
Router imported devices in the AD device list will be marked as AD-aware members. ad--show and ad --validate may return incorrect information about switch port members for non-AD aware switches running pre-v3.2 Fabric OS. This is because pre-v3.2 Fabric OS does not support Exchange Service Support - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 44
. Any changes made will be enforced only on ad --apply. Do you want to save admin domains (yes, y, no, n): [no] y 12 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 45
AD255 Transaction buffer configuration no configuration To display the AD10 configuration information in persistent storage: switch:admin> ad --show 10 -m 1 Current AD: 255 : AD255 Defined 1,2; 1,3; 1,4; 1,5; 1,6; 1,7; 1,8; 1,9; 1,10; 1,11; Fabric OS Command Reference Manual 13 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 46
1,3; 1,4; 1,5; 2,0**; 2,1**; 2,2**; 2,3**; 2,4**; 2,5**; Switch port members: Member is AD Unaware ** - Member does not exist 5,0*; 5,1*; 5,2*; 5,3*; 5,4*; 5,5*; 1,6; 1,7; 1,8; 1,9; 1,10; To abort the Admin Domain management transaction buffer: Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 47
transaction token is 26816 It is abortable switch:admin> ad --transshow There is no outstanding zoning transaction cfgSave, cfgTransShow, defZone, logout Fabric OS Command Reference Manual 15 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 48
the switch to a fabric you must set the default zone to "All Access" and disable/enable the E_Port". --mapshow [N_Port] 16 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 49
to be routed through this N_Port to the attached fabric. An F_Port cannot be mapped to more than one N_Port at the same time. F_Ports will be enabled only if the N_Port is online. If any mapping among the online N_Ports during the failback. Fabric OS Command Reference Manual 17 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 50
that are mapped to a given N_Port: switch:admin> ag --mapshow N_Port Configured_F_Ports Current_F_Ports Failover Failback 0 15;16 None 1 1 17 1;2;21 1;9 1 1 18 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 51
port 17 switch:admin> ag --failoverdisable 17 Failover policy is disabled for port 17 switch:admin> ag --failovershow 17 Failover on N_Port 17 is not supported switch:admin> ag --failbackdisable 17 Failback policy is disabled for port 17 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 52
2 ag See Also admin> ag --failbackshow 17 Failback on N_Port 17 is not supported switch:admin> ag --failbackenable 17 Failback policy is enabled for port 17 portCfgNPort, portCfgNPIVPort 20 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 53
: PortID Port WWN 0x010208 10:00:00:00:c9:3f:7c:86 0x01020a 10:00:00:00:c9:3f:7c:b9 Fabric OS Command Reference Manual 21 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 54
.90.231 v1.0.0 local 10:00:00:00:c8:3f:7c:b9 17 10.202.90.232 v1.0.0 remote portCfgNPIVPort 22 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 55
effect immediately. These changes are persistent across power cycles and reboots. For dual-domain systems, agtCfgDefault operates on the SNMP agent associated contact information for the system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for detailed sysDescr, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 56
agent's configuration back to factory default ***** Current SNMP Agent Configuration Customizable MIB-II system variables: sysDescr = Fibre Channel Switch. sysLocation = End User Premise sysContact = sweng (ro) No trap recipient configured yet 24 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 57
SNMP Agent Configuration Customizable MIB-II system variables: sysDescr = Fibre Channel Switch. sysLocation = End User Premise sysContact = Field Support. authTraps = 0 (OFF) SNMPv1 host configured yet See Also agtCfgSet, agtCfgShow, snmpConfig Fabric OS Command Reference Manual 25 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 58
take effect immediately. These values are persistent across power cycles and reboots. For dual-domain systems, this command operates on the SNMP agent contact information for the system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for detailed sysDescr, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 59
:admin> agtcfgset Customizing MIB-II system variables ... At each prompt, do one of the followings: o - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 60
snmpConfig, SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap", RFC1157, "A Simple Network Management Protocol (SNMPv1)", RFC1213, "Management information Base for Network Management of TCP/IP-based Internets: MIB-II" 28 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 61
the SNMP agent in the switch. On a dual-switch chassis, there is one SNMP agent per logical switch. This command is specific to the logical switch contact information for the system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for detailed sysDescr, sysLocation - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 62
:admin> agtcfgshow sysDescr = Fibre Channel Switch. sysLocation = End User Premise. sysContact = Field Support. authTraps = 0 (OFF) SNMPv1 community and trap recipient configuration: Community 1: Secret C0de ( host subnet area 10.32.147.255 (rw) 30 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 63
snmpConfig, SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap", RFC1157, "A Simple Network Management Protocol (SNMPv1)", RFC1213, "Management information Base for Network Management of TCP/IP-based Internets: MIB-II" Fabric OS Command Reference Manual 31 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 64
in quotation marks, separated by semicolons. This operand is required. An alias member can be specified by one or more of the following methods: • A switch domain and port area number pair. For ports ]" See Also aliDelete, aliRemove, aliShow 32 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 65
quotation marks, separated by semicolons. This operand is required. An alias member can be specified by one or more of the following methods: • A switch domain and port area number pair. View See Also aliAdd, aliDelete, aliRemove, aliShow Fabric OS Command Reference Manual 33 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 66
operand is required. Examples To delete the zone alias array2: switch:admin> alidelete "array2" See Also aliAdd, aliCreate, aliRemove, aliShow 34 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 67
removed from the alias, in quotation marks, separated by semicolons. An alias member can be specified by one or more of the following methods: • A switch domain and port area number pair. For ports See Also aliAdd, aliCreate, aliDelete, aliShow Fabric OS Command Reference Manual 35 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 68
:37:0c:76:8c alias: array2 21:00:00:20:37:0c:66:23 See Also aliAdd, aliCreate, aliDelete, aliRemove 36 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 69
a detailed performance-tuning discussion is beyond the scope of this manual. The default parameters are optimal for most SAN applications; typical The following polices are supported: 1 Port-based routing policy With this policy, the path chosen for an ingress frame is based on: • Ingress - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 70
aptPolicy Current Policy: 3 3: Default Policy 1: Port Based Routing Policy 3: Exchange Based Routing Policy To change the current policy: See Also Current Policy: 1 3: Default Policy 1: Port Based Routing Policy 3: Exchange Based Routing Policy dlsReset, dlsSet, dlsShow, switchDisable 38 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 71
list, re-issue -class option. All filters can be disabled by the -disable option. Based on the configuration, certain classes are logged to syslog for auditing. Syslog configuration is required for . 2-SECURITY 3-CONFIGURATION See Also none Fabric OS Command Reference Manual 39 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 72
key size and associated parameters implicitly. Higher group value provides stronger cryptography and higher level of security in authentication protocol. When on all E-ports; if the connecting switch does not support the authentication, then the E-port bring up will continue Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 73
slotnumber Specify the slot number for slot-bases switches. portnumber For directors, use protocol: switch:admin> authutil --set -a dhchap Authentication is set to dhchap. To set both protocols See Also To restart authentication for a director based switch, use the slot and port format for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 74
system. is supported only size is 16. The default value is 512 bytes. -pat type Specifies the test-pattern type to use in the test frame payload. Twenty types of predefined patterns are provided with the test; the default is jCRPAT (type=17). Use dataTypeShow to display the pattern types supported - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 75
backplaneTest 2 DATA TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. See Also itemList Fabric OS Command Reference Manual 43 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 76
applies to single blade as well as multiblade systems. The following items are tested: Proper backend the path has sent or received at least one frame. Area routing between user ports is not -extonly is set to 1. This command is supported only on Brocade 3250, 3850, 3900,4100, Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 77
list. With -extonly mode set to 1, the command sends only one burst of frames to each port from each ASIC pair-to-ASIC to all other ports. Send only one burst of frames to each link. Examples To test for backend detects failure(s), the test can report one or more of the following error messages - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 78
a newline to finish input): Do not log into this switch if you are not an authorized administrator. . See Also bannerShow 46 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 79
a switch: switch:admin> bannershow Banner: Do not log into this switch if you are not an authorized administrator. See Also bannerSet Fabric OS Command Reference Manual 47 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 80
all F_Ports and FL_Ports are members of the broadcast distribution tree. The broadcast path selection protocol selects the E_Port members of this tree in a manner designed to prevent broadcast routing loops typically set. See Also portRouteShow 48 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 81
blade beaconing or to display the current beaconing mode for one blade. When beaconing is enabled, the port LEDs only the beaconing pattern is displayed. If a diagnostic frame-based test (such as portLoopbackTest or spinSilk) is executed, Fabric OS Command Reference Manual 49 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 82
the remaining switches reconfigure, and this switch will configure based on the other blade ports. The blade must be the switch is disabled or when the blade itself is faulted, powered off, or running diagnostics. The execution of this command is Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 83
enable all user ports on a blade. All ports within the blade that did not fail the power-on self-test (POST) are enabled (except for persistently disabled ports); they might come online VACANT 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENABLED Fabric OS Command Reference Manual 51 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 84
2 bladeEnable See Also 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 UNKNOWN VACANT 9 UNKNOWN VACANT 10 UNKNOWN VACANT bladeDisable, portDisable, portEnable, switchShow 52 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 85
from which to clear burn-in errors. Examples To clear burn-in errors from slot 2. switch:admin> burninerrclear 2 See Also burninErrShow Fabric OS Command Reference Manual 53 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 86
which to display burn-in errors. Examples To display burn-in errors from slot 2: switch:admin> burninerrshow 2 See Also burninErrClear 54 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 87
burn-in testing in place of the power-on self-test (POST) phase II each time a switch blade is powered on. The mode becomes active as service. For multibladed products, this is the independent blade, and for fixed-port-count products, this is the chassis-persistent storage Manual 55 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 88
slot] slotnumber] Description Use this command to display the burn-in status of each blade in the system. The output contains the slot, state, current run number, current command in the run, total 41 923 Script burnin See Also diagSetBurnin 56 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 89
first disable the switch using the switchDisable command. This command is supported only on the Brocade 3250, 3850, 3900, and 24000 platforms. 57). passed. Diagnostics When failures are detected, the subtest might report one or more of the following error messages: DIAG-CAMFLTR DIAG-CAMINIT DIAG- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 90
2 camTest Refer to the Fabric OS Message Reference for more information. See Also centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 58 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 91
an enabled switch. You must first disable the switch using the switchDisable command. This command is supported only on the Brocade 3250, 3850, 3900, and 24000 platforms. The execution of this command Port 14 reads the central memory in ASIC 0. Fabric OS Command Reference Manual 59 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 92
ASIC X, ensure: interrupt status bits set. the error type is buffer number error. the port number in error is the receiver port (which is the base port of ASIC Y). Check that all ASICs besides X are not interrupted or flagged with an error. Reading the error register clears the CMEM interrupt bit - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 93
in error is the receiver port (which is the base port of ASIC Y). Reading the error register clears . By default, the test runs one time. -datatype type Specify the type of data pattern to is used. For a complete list of supported data patterns, run the dataTypeShow command. Manual 61 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 94
Diagnostics See Also When this command detects failure(s), each subtest can report one or more of the following error messages: Subtest 2 LCMEM_ERR LCMRS_ERR LCMTO_ERR cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 62 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 95
zone configuration that is currently in effect. The devices that an initiator sees are based on this configuration. The effective configuration is built when a specified zone configuration is cfgClear, cfgDelete, cfgRemove, cfgSave, cfgShow Fabric OS Command Reference Manual 63 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 96
in quotation marks and separated by semicolons. This operand is required. Members can be specified in one or more of the following ways: • Zone names • QuickLoop names • FA (Fabric Assist) , cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow 64 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 97
it is re-enabled. Do you want to save Defined zoning configuration only? (yes, y, no, n): [no] n See Also cfgDisable, cfgEnable, cfgSave Fabric OS Command Reference Manual 65 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 98
configurations. Blank spaces are ignored. The zone configuration member list must have at least one member. Empty member lists are not allowed. This command changes the defined configuration. cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow 66 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 99
is required. Examples To delete a zone configuration: switch:admin> cfgdelete "USA_cfg" See Also cfgAdd, cfgClear, cfgCreate, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow Fabric OS Command Reference Manual 67 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 100
any previous zoning configuration enabled. Do you want to disable zoning configuration? (yes, y, no, n): [no] y See Also cfgClear, cfgEnable, cfgSave 68 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 101
to enable 'USA_cfg' configuration (yes, y, no, n): [no] y zone config "USA_cfg" is in effect Updating flash ... See Also cfgClear, cfgDisable, cfgSave, cfgShow Fabric OS Command Reference Manual 69 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 102
quotation marks and separated by semicolons. This operand is required. Members can be specified in one or more of the following ways: • Zone names • QuickLoop names • FA (Fabric , cfgEnable, cfgSave, cfgShow, cfgTransAbort, cfgTransShow 70 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 103
in the fabric. The saved configuration is automatically reloaded by the switch on power on and, if a configuration was in effect at the time it was , cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgShow, cfgTransAbort, cfgTransShow Fabric OS Command Reference Manual 71 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 104
the fabric. There can be multiple zone configurations defined, but only one can be enabled at a time. There might be inconsistencies in the devices that an initiator sees in the fabric are based on this configuration. The effective configuration is built OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 105
:admin> cfgshow "*" cfg: USA1 Blue_zone cfg: USA_cfg Red_zone; Blue_zone See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgTransAbort, cfgTransShow Fabric OS Command Reference Manual 73 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 106
size details include the Zone DB maximum size, the committed size, and the transaction size. All sizes size, Admin Domain header size, and the zone database sizes for each Admin Domain. Zone DB maximum size maximum size is specified, the size of the . This size is in Zone DB max size - 1045274 bytes - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 107
. Examples To abort the current transaction: switch:admin> cfgtransabort See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, cfgTransShow Fabric OS Command Reference Manual 75 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 108
is 271010736 It is abortable (yes, y, no, n): [no] y See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, cfgTransAbort 76 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 109
CPs currently in the system are immediately rebooted, returning in the mode the user has specified. This can result in some blades being faulted as incompatible, based on the new configuration option. This command rejects without causing a reboot, if an option is not supported by the platform. Of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 110
All Supported Options (With Blade ID 5 on slots 5-6 Option 1: One One 384-port switches (Blade ID's 17, 18, 24, 31, 36 in slots 1-4, 7-1, Blade ID 16 in slots 5-6) Please use slotshow to see the Blade IDs currently in the system IDs they recognize based on the configuration Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 111
chassisConfig 2 Are you sure you want to continue? (Y/N): y Current Option changed to 1 Restoring switch 0 configuration to factory defaults... done. (Telnet connection goes down at this point.) See Also configDownload, configUpload, slotShow Fabric OS Command Reference Manual 79 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 112
Use this command to display or change the name associated with the chassis. In dual-domain systems, there are up to two logical switches associated with a single chassis. Operands This command :admin> chassisname dilbert See Also switchName 80 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 113
first line displays the chassis backplane version number, in hexadecimal. 2 Object type: CHASSIS, FAN, POWER SUPPLY, SW BLADE (switch), CP BLADE (control processor), WWN (World Wide Name), or Chassis Backplane Revision: 1C SW BLADE Slot: 3 Fabric OS Command Reference Manual 81 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 114
Num: Serial Num: . . . FAN Unit: 1 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Year: 2001 61 days 16 days 555-374757 236-296-12350 2836542 A.00 1 1000 60-0001536-02 A013450700 Day: 14 Month: 6 Year: 2001 Day: 15 Month Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 115
specified chip on the specified blade slot. The output of this command is for support use only. The command is supported only on Brocade 200E,3250, 3850, 3900, 4100, 24000, and 48000 platforms > chipregshow 1/1 ffffffff See Also minisPropShow Fabric OS Command Reference Manual 83 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 116
the test will be run one time. -datatype type Specify the type of data pattern to use. By default, type 9, QUAD_RAMP, is used. For a complete list of supported data patterns, run the . Diagnostics The following are possible error messages: 84 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 117
cmemRetentionTest 2 LCMEM_ERR LCMRS_ERR LCMTO_ERR Refer to the Fabric OS Message Reference for more information. See Also camTest, centralMemoryTest, cmiTest, dataTypeShow, itemList, portLoopbackTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 85 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 118
messages between the ASIC transmitter and receiver. This command is supported only on Brocade 3250, 3850, 3900,and 24000 platforms. The the number of test passes to run. By default, the test runs one time. -txports itemlist Specifies a list of ports to transmit data. By default Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 119
cmiTest 2 See Also camTest, centralMemoryTest, cmemRetentionTest, itemList, portLoopbackTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 87 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 120
attempt to use the same information to create new tunnels or modify the existing ones. Refer to the configure command for more information on default values for configuration none Examples To restore the system configuration to default values: 88 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 121
switch:admin> configdefault Committing Configuration ...done. See Also agtCfgDefault, configure, switchDisable, switchEnable configDefault 2 Fabric OS Command Reference Manual 89 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 122
required to change configuration if one of the CPs is running a version of FOS that does not support IPv6. To be able to mention the FTP server by name, you need to setup two DNS servers with dnsConfig. The first form of this command uses FTP (File Transfer Protocol). The FTP server must - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 123
] section, at least one member of the FCS_POLICY must MAX_HOPS are interrelated. Assigning a specific value to one or more of these parameters might change the range or -p scp Specifies the use of the FTP or SCP protocol. If a protocol is not specified, FTP is the default. "host" Specifies - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 124
"jdoe". This user name is used to gain access to the host system. Specifies the file name, in quotation marks: for example, "config the "switchDisable" command. switch:admin> switchdisable switch:admin> configdownload Protocol (scp or ftp) [ftp]: ftp Server Name or IP Address Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 125
. Do you want to continue [y/n]: y configDownload completed successfully. All parameters are downloaded. switch:admin> switchenable switch:admin> configDefault, configShow, configUpload, configure Fabric OS Command Reference Manual 93 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 126
regular expression operators is not supported. Some configuration settings will not display selectively in this manner. This operand is optional. If omitted, all system configuration settings are displayed. :portpost1.sh (continued on next page) 94 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 127
passes:5000 diag.test.passes:0 diag.test.portLoopback.passes:1000 diag.test.silkScreen.passes:180 diag.test.spinSilk.passes:120 fabric.ididmode:0 fabric.ops.BBCredit:16 fabric.ops.E_D_TOV:2000 fabric.ops.R_A_TOV:10000 fabric.ops.dataFieldSize:2112 fabric.ops Manual 53-1000436-01 configShow 2 95 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 128
.DomRscnToDevForSwChg.enable:0 ns.EndDeviceRscnFormat:1 oemLogo:0 perf.cfgver:1 perf.eemonchks:0 (output truncated) See Also agtCfgShow, configure, diagDisablePost, diagEnablePost, ipAddrShow, licenseShow, syslogdIpShow 96 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 129
Transfer Protocol). The FTP Server must be running in the host before an upload can occur. The configUpload command supports DNS ASCII strings and are listed one key per line. It is important to note that keys should not be moved from one section to another. Section Manual 97 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 130
Router configuration OS Administrator's Guide for details must setup one or more DNS use of the FTP or SCP protocol. If a protocol is not specified, FTP is the used to gain access to the host system. "file" Specifies the file name, interactively: switch:admin> configupload Protocol (scp or ftp) [ - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 131
Password: ******** configUpload complete: All config parameters except AD Headers,SFOS, and Security parameters are uploaded from AD0 configDefault, configDownload, configShow, configure Fabric OS Command Reference Manual 99 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 132
"RSCN Transmission Mode" • "Arbitrated Loop Parameters" • "System Services Settings" • "Portlog Events Enable/Disable Settings" • " domain, are assigned automatically by the fabric and might differ from one switch to another in the fabric. Other parameters, such as the Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 133
Data Field Size Sequence Level boolean boolean boolean number boolean boolean number boolean Hex Default 2000 0 7 2112 0 0 0 1 0 0 16 0 0x0 Range 1000 to R_A_TOV / 2 0 to R_A_TOV / 4 7 on the switch model and other system parameter settings. R_A_TOV The resource Manual 101 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 134
one To reduce problems, the Size The data field size specifies the largest possible value, in bytes, for the size systems when static PID binded is used. Per-frame Route Priority In addition to the eight virtual channels used in frame routing priority, support is also available for per-frame-based - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 135
buffers available to attached devices for frame receipt. The range of allowed values varies depending on other system settings (see Unicast-only Operation). Insistent Domain ID Mode When this mode is set, the switch 126 1 to 126*ports 1 to 255 Fabric OS Command Reference Manual 103 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 136
this is set, a CLS is returned immediately to an OPN if no buffers are available. This is required for TachLite. 104 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 137
. The protocol provides for a wide-range of system statistics; however, only the Ethernet interface statistics (see ifShow ) and system up time(see upTime) are supported. The retrieval of this information is supported by a number of operating systems that support RPC. Most UNIX-based systems (HP-UX - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 138
protocols must not be enabled before setting SSL attributes correctly. Operands none Examples To modify configuration settings on a switch: switch:admin> configure configure System services , switchDisable, switchEnable, upTime 106 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 139
the internal transmit path in ASIC 0. Only one frame is transmitted and received at any one time. The port LEDs flicker green while the test is running. The command is supported only on Brocade 200E,3250, 3850, 3900, data palette of seven are: Fabric OS Command Reference Manual 107 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 140
all ports are assumed to be cable loopbacked to different ports in the same switch. If one or more ports are not connected, the test aborts. All ports must be connected using ) loopback 3 Silkscreen loopback 5 Internal (parallel) loopback 108 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 141
Specify the speed mode for the test. This parameter is used only for Bloom and Condor ASIC-based products, for which it controls the speed at which each port is operated. For 1 Gbit/sec portLoopbackTest, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 109 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 142
7f 7f 7f 7f 7f 7f 7f 7f 7f 7f 7f 7f 20 00000000 11111111 22222222 33333333 See Also none 110 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 143
change in date and time to one switch is forwarded to the principal more information on time zone support. If the switch is operating format, as used on many UNIX systems: mmddHHMMyy Where mm is the month, 2000 switch:admin> date "0227123003" Fabric OS Command Reference Manual 111 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 144
2 date See Also Thu Feb 27 12:30:00 UTC 2003 errShow, ficoncupset, ficoncupshow, portLogShow, tsClockServer, tsTimeZone, upTime 112 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 145
To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg Fabric OS Command Reference Manual 113 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 146
Access, initialize a zoning transaction (if one is not already in progress), and create initializes a zoning transaction (if one is not already in progress a remote switch that does not support default zoning, zoning rejects the initiates a zoning transaction (if one is not already in progress), and - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 147
--noaccess switch:admin> cfgsave switch:admin> defzone --show Default Zone Access Mode committed - No Access transaction - No Transaction See Also none Fabric OS Command Reference Manual 115 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 148
effect switch:admin> defzonecreate switch:admin> cfgactvshow Default Zone Access Mode committed - All Access transaction - No Transaction See Also defZoneDelete 116 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 149
a default zone configuration: switch:admin> cfgactvshow Effective configuration: no configuration in effect switch:admin> defzonedelete switch:admin> cfgactvshow See Also defZoneCreate Fabric OS Command Reference Manual 117 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 150
diag software flag: switch:admin> diagclearerror 8 ERROR: DIAG CLEARERR Diagnostics Errors Cleared, port: 8/31 Err# 0120041 081F See Also none 118 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 151
this command on the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. This availability is offered contents (output truncated) See Also diagHelp Fabric OS Command Reference Manual 119 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 152
command to disable POST. A reboot is not required for this command to take effect. Operands none Examples To disable the POST during future power ons: switch:admin> diagdisablepost Config update Succeeded Diagnostic POST is now disabled. See Also diagEnablePost 120 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 153
I mainly tests hardware and POST Phase II tests system functionality. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Examples To enable the POST during future power ons: switch:admin> diagenablepost Config update Succeeded Diagnostic - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 154
command on the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. This availability is offered USR_MEMDLY DIAG_USR_MEMDLY Value 1 10 122 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 155
See Also USR_SEED DIAG_USR_SEED USR_SPECIAL DIAG_USR_SPECIAL (output truncated) none diagEnv 2 0x0 0x0 Fabric OS Command Reference Manual 123 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 156
5: switch:admin> diagfaillimit -show Fail Limit is 1. switch:admin> diagfaillimit 5 Fail Limit is now 5. Config update Succeeded See Also none 124 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 157
Nondefault settings require detailed knowledge of the underlying hardware and are intended for support personnel only. Contact support if you want to use these operands. The execution of this command is . dump port buffer contents See Also none Fabric OS Command Reference Manual 125 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 158
issue this command on the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. This availability is offered to maintain ID is 125. See Also none 126 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 159
18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature (type=INDEX, sz=512): 100. = 1 = 0 = OFF = OFF See Also burninLevel, setEsdMode, setGbicMode, setSplbMode Fabric OS Command Reference Manual 127 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 160
the behavior of the diagnostics daemon program to inhibit testing of switch blades when the system is first powered on or a new blade is added. To enable or disable diagnostic POST, the enabled. See Also diagDisablePost, diagEnablePost 128 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 161
does not require a reboot to take effect. Retry mode modifies the behavior of the diagnostic test methods, power-on self-test (POST), and burn-in scripts. The exact behavior depends on the tests and scripts is currently enabled. See Also none Fabric OS Command Reference Manual 129 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 162
in parameters for the registered burn-in script. The burn-in will start at the next run of power-on self-test (POST) on the designated blade(s). The errors and activity logs are stored in update Succeeded See Also burninErrShow, diagSetCycle 130 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 163
be updated noninteractively using this style of option list. value is the keyword to update; the value should be specified manually in this case. Examples To update diagnostic command parameters: switch:admin> diagsetcycle switchburnin.sh -show CURRENT - KEYWORD : DEFAULT 1 - number_of_runs - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 164
operate on fixed-port-count products. By default, this command displays all user ports in the system. -uports itemlist Specify a list of user ports to display. -bports itemlist Specify a list ...... (output truncated) See Also itemList 132 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 165
this command on the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. This availability is offered Time mode is now 1 (Enabled). See Also none Fabric OS Command Reference Manual 133 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 166
is displayed. Examples To display the current skip test flags: switch:admin> diagskiptests -show Skip tests is 1. See Also none 134 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 167
blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other to display. If omitted, all blades in the system are assumed. Examples To display currently running diagnostic tests Fabric OS Command Reference Manual 135 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 168
:45:36 Switch: 0, Error DIAG-MANUAL1, 1, " 1 switchess: ABORT ... Err# 0140042 0100:101:000:002:26:41:1N See Also diagSetBurnin 136 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 169
the policy sets currently supported; namely SCC Switch Connection Policy Each supported database has specified to include all switches in the fabric that support the distribute feature. Switches prior to v5.3. ignore in the fabric that support the distribute feature: switch:admin> distribute -p - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 170
5 To distribute the Switch Connection FCS policy and Password database to all domains in the fabric that support the distribute feature: switch:admin> distribute -p "FCS;PWD" -d "*" To distribute the AUTH amd FCS , AUTH and IPF. See Also fddCfg 138 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 171
if devices connected to the fabric cannot handle occasional routing changes correctly. DLS is not supported in certain routing policies. Refer to aptPolicy for more information on routing policies. The set See Also aptPolicy, dlsSet, dlsShow Fabric OS Command Reference Manual 139 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 172
when a fabric change occurs. Routing is generally based on the incoming port and the destination domain. placed, existing routes are never moved from one output E_Port to another unless the original on by default. DLS is not supported in certain routing policies. Refer to Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 173
Description Use this command to display whether DLS is on or off. One of two messages displays: DLS is set The DLS option is turned to dlsSet for a description of load sharing. DLS is not supported in certain routing policies. Refer to aptPolicy for more information on Manual 141 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 174
remove the domain name service parameters. The domain name service parameters are the parameters for the system: switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration successfully Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 175
meaningful for the products that are embedded in a blade server or storage chassis. Most of the options are applicable to a specific platform. do not apply to a platform are identified with a "Not supported on this platform" message. The execution of this command is subject Manual 143 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 176
To display the identifier of the enclosure interface to which the switch is attached: switch:admin> enclosureShow slotid Bay 4 chassisShow 144 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 177
that may be in place. Operands none Examples To clear the error log messages: switch:admin> errclear See Also errDump, errShow Fabric OS Command Reference Manual 145 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 178
, SWITCH43, Name Server received an invalid request from device 10:02:32:A3:78:23:23:End errDump, errFilterSet, errShow 146 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 179
/07/14-22:25:29, [SEC-1192], 3,, INFO, switch2, Security violation: Login failure attempt via SERIAL. See Also errDelimiterSet, errFilterSet, errShow Fabric OS Command Reference Manual 147 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 180
Use this command to set a filter for an error log destination. A filter is set based on the severity level of the messages. If no parameters are specified, this command displays the admin> errfilterset -d "console" -v "WARNING" errDump, errShow 148 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 181
CHPS CONF CPT DIAG EM ERRL FABR FABS FCIU FCMC FCPD FCPH FICU FILB FKLB (output truncated) See Also errDump, errShow Fabric OS Command Reference Manual 149 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 182
this command to display external error log messages for all switch instances and the chassis, one at a time. The -r operand displays the messages in a reversed order. The continue, Q to stop: See Also errDelimiterSet, errDump, errFilterSet 150 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 183
beginning of a line. Operands none Examples To exit from a shell session: switch:admin> exit Connection to host lost. See Also logout Fabric OS Command Reference Manual 151 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 184
received from the port 0x00000100 Port truly connected to E_Port 0x00000200 Segmented by routing code 0x00000400 fspf has completed routing 152 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 185
place. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port to display, followed the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display fabric port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 186
2 fabPortShow See Also Flags: nbrWWN: nbrPort: lr_tid: red_ports: 10 11 62 63 0x280120 10:00:00:60:69:80:06:cf 5 0x1005dbd8, IDLE STATE Open commands pending No commands pending portShow 154 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 187
E_Port ELP EFP HA_EFP DIA RDI BF FWD EMT ETP RAID GAID ELP_TMR GRE ECP 16 0 0 00 0 0 0 0 0 0 0 0 0 0 17 0 0 0 0 0 0 0 0 0 0 0 0 0 0 See Also fabStatsShow Fabric OS Command Reference Manual 155 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 188
enabled. -e | --enable Enables fabric log. -r size | --resize size Changes the maximum number of log entries. The given size has to be at least 2 and a power of 2; otherwise, the command fails. Examples To logs. (continued on next page) 156 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 189
fabricLog 2 See Also Are your sure you want to do the resize [y/n]? y switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port Xid fabPortShow, fabStatsShow Fabric OS Command Reference Manual 157 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 190
switch selection mode for the switch. The implementation of the fabricPrincipal command is based solely on mechanisms specified in the Fibre Channel standards. These mechanisms provide a Mode enabled (Forcing fabric rebuild) fabricShow 158 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 191
not an FC Router of it the FC Router does not support it. FC Router Name The FC Router symbolic name. This field will be empty if the switch is not an FC Router of it the FC Router does not support it. The Enet IP Addr FC IP Addr Name Fabric OS Command Reference Manual 159 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 192
-m Switch ID Name ENET IP Addr FC Router FC Router IP Addr Name 1: fffc01 fcr_sprint_01 10.33.59.224 160: fffca0 fcr_fd_160 0.0.0.0 10.33.59.25 fcr_meteor2 190: fffcbe fcr_mojo_6 10.33.59.32 The Fabric has 3 switches switchShow 160 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 193
21 0x277 switch:admin> fabstateclear switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid See Also fabStateShow, fabricLog Fabric OS Command Reference Manual 161 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 194
the logged entries. This command is obsoleted by fabricLog -r size. The execution of this command is subject to Admin Domain New number of entries. It has to be at least 2 and a power of 2; otherwise, the command fails. Examples To change the number of entries Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 195
40 0x294 11958:497 EFP ACC Receive F2,P3 F2,P3 40 0x294 (output truncated) See Also fabPortShow, fabStateClear, fabStateResize, fabricLog Fabric OS Command Reference Manual 163 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 196
forcibly changed: 0 E_Port offline transitions: 0 Reconfigurations: 1 Segmentations due to: Loopback: 6 < Incompatibility: 0 Overlap: 0 Zoning: 0 E_Port Segment: 0 Licensing: 0 Disabled E_Port: 0 Platform DB: 0 164 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 197
Sec Incompatibility: 0 Sec Violation: 0 ECP Error: 0 Duplicate WWN: 0 Eport Isolated: 0 See Also fabRetryShow fabStatsShow 2 Fabric OS Command Reference Manual 165 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 198
recovery list: no domain RSCN's to recover reachable domains: 1 3 4 3 domains reachable Ports used for EFP/BF/DIA flood: (output truncated) 166 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 199
See Also supportShow fabSwitchShow 2 Fabric OS Command Reference Manual 167 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 200
nonfaulty fan unit by setting the RPM speed to 0. This command is not available on nonbladed systems except for the Brocade 4100 and 4900. The execution of this command is subject to Admin Domain 1 has been disabled See Also fanEnable, fanShow 168 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 201
disabled fan unit back to the default RPM speed. This command is not available on nonbladed systems except for the Brocade 4100 and 4900. The execution of this command is subject to Admin unit 1 has been enabled See Also fanDisable, fanShow Fabric OS Command Reference Manual 169 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 202
to display the current status and speed of each fan in the system. Fan status is displayed as: OK Fan is functioning correctly. absent may be in place. Operands none Examples To display information on the fans in the system: switch:admin> fanshow Fan #1 is OK, speed is 2721 RPM Fan #2 is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 203
bypassing Power-On Self-Tests (POST). Synopsis fastboot Description Use this command to immediately reboot the CP. This command is similar to reboot, but skips POST when the system comes See Also diagDisablePost, diagEnablePost, reboot Fabric OS Command Reference Manual 171 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 204
storage latency and improves the number of write transactions per second over long distances. Synopsis fastwritecfg Description Use this command to configure the blade in a given slot (slot = 0 for the Brocade 7500). This command is supported only for FR4-18i and Brocade 7500 systems based system. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 205
requires power-cycling of the affected blade to take effect and may take up to 5 minutes to complete. Non-bladed switches will be rebooted. In all cases, data traffic on all the ports (FC and GbE) of the blade will be disrupted. Continue (Y,y,N,n): [ n] portcfg Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 206
be enclosed in quotation marks and members separated by semicolons. A member can be specified by one or more of the following methods: A fabric domain and area number pair (for example, " fazoneCreate, fazoneDelete, fazoneRemove, fazoneShow 174 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 207
are created with the aliCreate command. The alias must resolve to a list of one or more physical fabric port numbers, WWNs, or a Fabric Assist host. A Fabric Assist semicolons. A member can be specified by one or more of the following methods: Fabric OS Command Reference Manual 175 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 208
"10:49:00:00:00:20:3f:2e"). Fabric Assist zone alias names. Exactly one Fabric Assist host member (for example, "H{1,2}"). This operand is required. Examples To create H{1,2}; array2" See Also fazoneAdd, fazoneDelete, fazoneRemove, fazoneShow 176 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 209
marks. This operand is required. Examples To delete a Fabric Assist zone: switch:admin> fazonedelete "Blue_fazone" See Also fazoneAdd, fazoneCreate, fazoneRemove, fazoneShow Fabric OS Command Reference Manual 177 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 210
...]" Description Use this command to remove one or more members from an existing Fabric Assist separated by semicolons. A member can be specified by one or more of the following methods: A fabric domain and . Fabric Assist zone alias names. Exactly one Fabric Assist host member (for example, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 211
Fabric Assist zones beginning with the letters A through C: switch:admin> fazoneshow "[A-C]*" fazone: Blue_fazone 1,1; array1; 1,2; array2 See Also fazoneAdd, fazoneCreate, fazoneDelete, fazoneRemove Fabric OS Command Reference Manual 179 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 212
network processor, FCIP FPGA, compression processor, and GigPHY. This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command When a failure is detected, the test might report one or more of the following error messages: CHIP_TEST_ERR - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 213
See Also fcipPathTest fcipChipTest 2 Fabric OS Command Reference Manual 181 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 214
from and received by the network processor due to the designated loopback. This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has switch:admin> fcippathtest --slot 2 -path 2 -nframes 10 182 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 215
passed. Diagnostics See Also When a failure is detected, the test might report one or more of the following: PATH_TEST_ERR PATH_TEST_CHIP_INIT_ERR PATH_TEST_IMAGE_ERR PATH_TEST_TIMEOUT_ERR PATH_TEST_HEARTBEAT_ERR PATH_TEST_INVALID_RESULT PATH_TEST_GE_PORT_ENABLE_ERR PATH_TEST_GE_PORT_DISABLE_ERR - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 216
:00:00:60:69:e2:09:c8 Port WWN: 21:fd:00:60:69:e2:09:c8 fosConfig, iscsiCfg, iscsiPortCfg 184 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 217
Link Service (ELS if this is due to the device not supporting this ELS Echo request. Do not assume data, the Fibre Channel Echo request frame size is 12 total bytes. This is a . This is useful for diagnosing data-dependent problems in the fabric link. The pattern bytes are Manual 185 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 218
frames rejected, 0 frames timeout Round-trip min/avg/max = 0/0/0 usec See Also To display one device that accepts the request and another device that does not respond to the request: switch:admin min/avg/max = 0/0/0 usec gettimeofday, ping 186 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 219
be in place. Operands none Examples To clear the FCPD debug information log: switch:admin> fcplogclear See Also fcpLogDisable, fcpLogEnable, fcpLogShow Fabric OS Command Reference Manual 187 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 220
in place. Operands none Examples To disable the FCPD debug information log: switch:admin> fcplogdisable See Also fcpLogClear, fcpLogEnable, fcpLogShow 188 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 221
be in place. Operands none Examples To enable the FCPD debug information log: switch:admin> fcplogenable See Also fcpLogClear, fcpLogDisable, fcpLogShow Fabric OS Command Reference Manual 189 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 222
ElsRsp 26 1 1606 11ace :2000000 :0 :0 :980000 22:34:14.247 IUDel 26 1 1731 1002a690:1002a690:0 :0 :1 See Also fcpLogClear, fcpLogDisable, fcpLogEnable 190 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 223
fcpProbeShow Displays the Fibre Channel Protocol (FCP) probe information. Synopsis in place. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to display, followed by Fabric OS Command Reference Manual 191 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 224
Displays the Fibre Channel Protocol (FCP) Read Link Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is required. Examples 0 See Also portLoginShow, portLogShow 192 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 225
of the switch. switch:admin> frcbcastconfig --show Broadcast configuration is disabled for: fid 2 fid 128 fid 33 SEE ALSO bcastshow, portRouteShow Fabric OS Command Reference Manual 193 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 226
is supported only on Router FPGA Examples To run all tests on slot 7 and FC Router FPGA 1: switch:admin> fcrchiptest --slot 7 -unit 1 -testtype 0 Running fcrchiptest Test Complete: fcrchiptest Pass 1 of 1 Duration 0 hr, 0 min & 4 sec (0:0:4:351). passed. 194 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 227
2 Diagnostics When a failure is detected, the test might report one or more of the following: DMA_ALLOC_FAIL DMA_READ_ABORT DMA_READ_TIMEOUT CHIP_INIT_TIMEOUT BIST_TIMEOUT BIST_FAIL See Also fcrPathTest, miniCycle, portLoopbackTest Fabric OS Command Reference Manual 195 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 228
execute on a system with the FC Router feature enabled. First ID uniquely identifies a fabric in FC Router configurations. The backbone fabric is the fabric across all FC Router-connected fabrics. The current Backbone configure FC Router parameters: fcr:admin> fcrconfigure FC Router parameter set - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 229
FC Routing service on a switch. This command is not supported in v5 too soon, the following message is displayed: "FC Routing service is in the process of being disable, please try again service Operands none Examples To disable the FC Routing service: fcr:admin> fcrdisable FC Routing service - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 230
fcrEnable Enables the FC Routing service on the switch. This command is not supported in v5.3.0; instead use fosConfig. Synopsis fcrenable Description Use this command to enable the Fibre Channel (FC) Routing service on a switch. In Fabric OS v5.1 the FC Routing service is enabled by default. In - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 231
support. When IPv6 addresses are not configured, the output of fabricshow is the same as it is currently. The message "No active FC Routers found" is displayed if no active FC Routers are present on the backbone fabric. An active FC Router is an FC Router with at least one N/A FC Router WWN: 10 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 232
or display the maximum number of LSAN zones that can be configured on the router. By default, this limit is set to 3000, which is also the is also displayed with command fcrresourceshow. Only 3000 or 5000 are supported as valid count. Operands If no operands are specified, this Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 233
best practice is to enter the same information for all the FCR switches in the backbone that supports this command. Using the command options, the user can do the following: Update the cached , the edge fabric assumes the default behavior. Fabric OS Command Reference Manual 201 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 234
the backbone: For example, in the backbone where online fabrics are: 1, 2, 4, 5, 7, 8, 10 switch:admin > fcrlsanmatrix --fabricview LSAN MATRIX is activated 202 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 235
1 Fabric ID 2 52 78 52 82 78 82 Default LSAN Matrix: 57 91 See Also fcrFabricShow, lsanZoneShow, fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, switchShow Fabric OS Command Reference Manual 203 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 236
any one time. External cable is not required to run this test. The port LEDs flicker green rapidly while the test is running. The test method is as follows: Set all ports present for parallel loopback. Create a frame F of maximum data size (2,112 bytes). Transmit frame F by way of the FC Router FPGA - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 237
supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count products. -unit number Specifies the FC Router - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 238
Routers on the same backbone fabric as this FC Router. The default output displays only physical device information relevant to this FC Router to this FC Router's EX_Ports. The physical devices are listed by fabric. The -f and -w operands allow searching for physical devices based on fabric ID - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 239
fcrPhyDevShow 2 in Fabric 2 10:00:00:00:c9:2b:6a:68 c70000 3 50:05:07:65:05:84:09:0e 0100ef 3 50:05:07:65:05:84:0b:83 0100e8 Total devices displayed: 3 See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual 207 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 240
. If the configuration is altered, then care must be taken to ensure consistency across all FC Routers attached to the same edge fabric. The following information is displayed if no optional operand is given used for the specified edge fabric. 208 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 241
-r 5 00:11:22:33:44:55:66:77 WWN deleted from proxy device slot See Also fcrPhyDevShow, fcrProxyDevShow, fcrXlateConfig, lsanZoneShow, switchShow Fabric OS Command Reference Manual 209 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 242
are listed by fabric. Search parameters -f and -w allow searching for proxy devices based on fabric ID or port WWN. "No proxy device found" is displayed if there is no proxy device information available on this FC Router. Each line of output displays: Proxy Created in Fabric The fabric in which - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 243
with the specified port WWN. Examples To display the physical devices relevant to this FC Router: switch:admin> fcrphydevshow Device WWN Physical Exists PID in Fabric 2 10:00:00:00 , fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual 211 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 244
port WWNs are not returned to the pool until the system reboots, because the phantom switch might still be accessible through reboot, the allocation starts from the next usable WWN base from the pool and not from the beginning. Port Router: 212 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 245
Port WWN: WWN Pool Size Allocated 8192 3790 32768 6446 Port Limits: Max proxy devices: 2000 Max NR_Ports: 1000 Currently Used(column 1: displayed. See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual 213 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 246
] Description Use this command to set or display the cost of the router ports. The cost of the link is a dimensionless positive number (which can be 0 or 1000 or 10000). The router module chooses the router port path based on the minimum cost per fid connection. If multiple paths exist with the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 247
To set the cost of an EX_Port: switch:admin> fcrrouterportcost 7/10 10000 See Also switchShow, fcrRouteShow, portCfgEXPort fcrRouterPortCost 2 Fabric OS Command Reference Manual 215 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 248
meta-SAN. There are FC Router ports that reside on the AP7420, there is a one-to-one relationship between an NR_Port supported, an NR_Port provides a path to a single fabric with a single FC Router protocol Router protocol cost (for routing decisions) for this NR_Port. The FCRP cost is the same (1000 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 249
domain ID in the future. Information displayed is not related to the entire BB. The FC Router displays only connections to an edge fabric for which there are xlate domain IDs. Any changes you To display the translate domain configuration: Fabric OS Command Reference Manual 217 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 250
created in fabric 2 that represents remote fabric 3: switch:admin> fcrxlateconfig -r 2 3 xlate domain deleted See Also portCfgEXPort, portCfgVEXPort, portDisable, portEnable, portShow 218 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 251
fabric-wide policy to NULL (default) or no fabric-wide consistency, use the policy Set "". Supported policies are Switch Connection Control (SCC) and Device Connection Control (DCC). Examples To display the SCC policy set and PWD database: Fabric OS Command Reference Manual 219 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 252
-Wide Consistency Policy to "strict" for SCC and "tolerant" for DCC: switch:admin> fddcfg --fabwideset "SCC:S;DCC" See Also distribute 220 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 253
:96 Ports: 1 10:00:00:00:c9:25:9b:96 Total count of devices on the switch is 1 See Also fdmiShow Fabric OS Command Reference Manual 221 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 254
Supported Speed: 0x00000001 Port Speed: 0x00000001 Frame Size 2000 Max CT Payload Length: 0x00061300 Local Port database contains: 10:00:00:00:c9:25:9b:96 Remote HBA database contains no entry. Remote Port database contains no entry. See Also fdmiCacheShow 222 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 255
. To clear RNID database: switch:user> ficonclear RNID successfully clear not current entries from local RNID Database. See Also ficonHelp, ficonShow Fabric OS Command Reference Manual 223 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 256
fmsmode. modereg Set a bit in the FICON-CUP mode register. When the operand is modereg, one of the following bitname operands should be specified, followed by 0 or 1: POSC Programmed offline state control set to 1 See Also ficoncupshow 224 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 257
the switch. modereg Display the FICON-CUP mode register. When parameter is modereg, one of the following arguments can be specified as bitname: POSC Programmed offline state control > ficoncupshow modereg ASM ASM --1 See Also ficoncupset Fabric OS Command Reference Manual 225 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 258
commands. Synopsis ficonhelp Description Use this command to display a list of FICON support commands, with descriptions. Operands none Examples To display a list of FICON commands: the specified FICON management database See Also none 226 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 259
] where database is one of the following: as follows: 0x00 Indicates node ID of the storage port for RNID switch for SwitchRNID is valid. 0x40 Indicates the node ID of the storage port for RNID switch for RLIR is failure type as one of the following: WWN card [unit number] Power Supply [unit - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 260
Link Incident Type. Link Incident Type Indicates the link incident type as one of the following: Bit-error-rate threshold exceeded Loss of signal or and other FC-4s including FCP and updates. 0x80 FC-4 support not specified. 0xa0 Reserved. 0xc0 Reserved. 228 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 261
screen if it is an storage port; otherwise, a reserved field for a channel port. 0x08 Terminal - Line mode if it is an storage port; otherwise, an emulated control unit support only. 0x09 Reserved. 0x10 Switch : U is unknown. N is N_Port. Fabric OS Command Reference Manual 229 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 262
Protocol Displays whether the traffic is using FICON or FCP. Registered Node WWN Displays the device's node World Wide Name associated with the device HBA. Registered Port WWN Displays the device's channel or storage Plant of Manufacture: 02 230 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 263
50:05:07:64:00:c1:69:ca Type Number: 002064 Model Number: 101 Manufacturer: IBM Flag 0x50 Node Parameters 0x200105 Fabric OS Command Reference Manual 231 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 264
local ILIR database: switch:user> ficonshow ILIR { {FRU Failure [2]: Power Supply[2] failure occurred on Mon Jan 13 12:11:38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 FICON 80 10:00:00:60: has 2 entries. See Also ficonClear 232 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 265
the subgroup A-based filtering. FLTACT_LIST_B Action to handle the subgroup B-based filtering. FLTACT_FROZEN Frozen 11 Zone A|B match and AL_PA match Discard Operands This command is supported only on Brocade 3250, 3850, 3900,12000, and 24000 platforms. The Reference Manual 233 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 266
filtertest Test Complete: filtertest Pass 1 of 1 Duration 0 hr, 0 min & 2 sec (0:0:2:679). passed. Diagnostics When it detects failures, the subtest might report one or more of the following error messages: DIAG-ACTTEST DIAG-FLTINIT DIAG-FLTRCV DIAG-FLTXMIT DIAG-NUMTEST Refer to the Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 267
into two equal partitions, the primary partition is the where the system boots from; the secondary partition is where a copy of the firmware firmwareDownload, after the CP is rebooted, you must execute one of two commands: firmwareCommit copies the primary partition (with Manual 235 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 268
services. This operation depends on HA support. If HA is not available, you can still upgrade the CPs one at a time, using the -s option. All systems supported by this firmware have two partitions of nonvolatile storage example software error or power failure, the command will Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 269
non-bladed systems. On bladed systems, this firmware, the system must be rebooted to both partitions of the storage device. host Specify a valid scp|ftp> Specify the file transfer protocol used to download the firmware from firmwareCommit determines the protocol automatically by checking system - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 270
in the system during SAS Fabric OS Administrator's Guide "Firmware Download" chapter BP blades are installed in the system. Slot Name Versions Scope of or IP Address: 192.168.32.10 Network Protocol (1-auto-select, 2-FTP, 3-SCP) [1]: User system parameters before firmwaredownload. It can fail if one - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 271
format, or is corrupted The FTP or SSH service is not running on host Platform is not supported by the firmware indicated. For other return codes, refer to the Fabric OS Error Message Reference Manual. See Also firmwareCommit, firmwareDownloadStatus, firmwareRestore, firmwareShow, reboot, version - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 272
is issued. There is a timestamp associated with each event. When downloading SAS or SA in systems with two control processor (CP) cards, you can only run this command on the active CP commit has completed. (Firmwaredownload has completed.) 240 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 273
8 (FR4-18i): Firmware has been downloaded successfully. Blade is rebooting with the new firmware. [9]: Mon Dec 19 18:50:12 2005 Fabric OS Command Reference Manual 241 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 274
5 (CP0, active): Firmwaredownload command has completed successfully. Use firmwareshow to verify the firmware versions. See Also firmwareCommit, firmwareDownload, firmwareRestore, firmwareShow 242 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 275
again. This command reboots the system and makes the former firmware active This command only takes action if the system is booted after a firmwareDownload; otherwise, Restore both primary and secondary image after reboot. The system is going down for reboot NOW !! Broadcast message - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 276
director. It shows the firmware versions on both the primary and secondary partitions of the storage device. Operands none Examples To display the firmware versions in a Brocade director with FA4 Also firmwareDownload, firmwareDownloadStatus 244 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 277
one frame is transmitted and received at any one time. The port LEDs rapidly flicker green while the test is running. This command is supported with payload size, data pattern build in or payload size, data frame. The data pattern is generated based on data type. Some data Manual 245 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 278
4 CQRT_SQ 5 CRPAT 6 RANDOM All other values are modularized into one of these values. -width pattern_width Specify the width of the pattern 1 byte (default) 2 word 4 quad This operand is optional. -size pattern_size Specify the number of words in the test packet payload. If Manual 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 279
STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. itemList, loopPortTest, portTest, spinFab fportTest 2 Fabric OS Command Reference Manual 247 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 280
a switch. The following features are supported (see Notes for limitations): FC Routing service (see fcrConfigure) iSCSI service (see iscsiCfg) iSNS client service (see isnscCfg) Operands This command has offline and try the command again. 248 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 281
a feature that is not supported on your platform, an error message stating "Command not supported on this platform" is displayed. Examples To display the status of the features: switch:admin> fosconfig --show FC Routing service: iSCSI service: iSNS Client service: enabled enabled disabled To - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 282
this command to guide the user in being replaced. WWN is the only supported value, specifying the replacement of the is not complete due to a power cycle, or CP failover, please follow the the frureplace command and follow the instructions to complete the operation. Please Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 283
agingTID agingTo lsrDlyTID lsrDelayTo lsrDelayCount ddb_sem event_sch Version of FSPF protocol. Domain number of local switch. State of the local place. Operands none Examples To display FSPF protocol information: switch:admin> fspfshow Fabric OS Command Reference Manual 251 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 284
= 0x1003e630 agingTID = 0x1004ca28 agingTo = 10000 lsrDlyTID = 0x100507a8 lsrDelayTo = 5000 lsrDelayCount = 1 ddb_sem = 0x1003e6e8 fabP: event_sch = 0x0 See Also bcastShow, topologyShow, uRouteShow 252 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 285
Fabric Watch: switch:admin> fwalarmsfilterset FW: Alarms are already disabled switch:admin> fwalarmsfilterset 1 FW: Alarms are aleady enabled See Also fwAlarmsFilterShow Fabric OS Command Reference Manual 253 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 286
in Fabric Watch: switch:user> fwalarmsfiltershow FW: Alarms are enabled switch:user> fwalarmsfiltershow FW: Alarms are disabled See Also fwAlarmsFilterSet 254 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 287
Fabric Watch: switch:admin> fwclassinit fwClassInit: Fabric Watch is updating... fwClassInit: Fabric Watch has been updated. See Also fwConfigReload, fwConfigure, fwShow Fabric OS Command Reference Manual 255 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 288
the saved Fabric Watch configuration: switch:admin> fwconfigreload fwConfigReload: Fabric Watch configuration reloaded See Also configDownload, configUpload, fwClassInit, fwConfigure, fwShow 256 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 289
. This command requires a Fabric Watch license. Not all platforms support fans or power supplies. If you attempt to configure values for these items, Fan* Power Supply* Temperature RXP TXP Current Voltage Link failure Sync loss Signal loss Protocol error Invalid Manual 257 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 290
following classes are supported. F/FL Port (Copper) class is supported only on Embedded platforms. .. TABLE 12 Class Access Gateway Mode Area Environmental SFP Port Temperature Fan* Power Supply* Temperature RXP TXP Current Voltage Link failure Sync loss Signal loss Protocol error Invalid words - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 291
CRCS RX Performance TX Performance Customer Defined Flash Not all platforms support fans or power supplies. If you attempt to configure values for these items the a class => : (1..12) [1] 1 1 : Temperature 2 : Fan 3 : Power Supply 4 : return to previous page Select an area => : (1..4) [4] 1 Index - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 292
2000 0 C Informative 2 envTemp002 enabled 34 C started 10:28:59 on 02/01/2000 0 C Informative 3 envTemp003 enabled 36 C started 10:28:59 on 02/01/2000 1 1 : Temperature 2 : Fan 3 : Power Supply 4 : return to previous page Select an area Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 293
and actions. Based on these Power Supply Alarm Action: (0..17) [0] Fan Alarm State: (0..31) [0] Fan Alarm Action: (0..17) [0] WWN Alarm State: (0..31) [0] WWN Alarm Action: (0..17) [0] Fru configuration successfully changed See Also fwConfigure, fwMailCfg Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 294
parameters switchStatusPolicyShow Show switch status policy parameters switchStatusShow Show overall switch status tempShow Show switch temp readings See Also none 262 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 295
monitored by Fabric Watch are divided into classes, and email alerts are based on the classes. Each class can configure one email address as the alert message's receiver. For an email alert Email Alert 3 : Enable Email Alert 4 : Send Test Mail Fabric OS Command Reference Manual 263 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 296
an item => : (0..13) [11] 1 Mail To: [NONE] [email protected] Email Alert configuration succeeded! See Also dnsConfig, fwConfigure, ipAddrSet, ipAddrShow 264 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 297
is calculated based on the Number of protocol errors power is out of specification SCU SFP current is out of specification SVO SFP voltage is out of specification The overall status may be in one of the following: Healthy Every contributor is healthy Marginal One Manual 265 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 298
. Valid portState entries are: h Report based on all healthy ports m Report based on all marginal ports f Report based on all faulty ports o Report based on all offline ports If no option is :58 PM --------Port-Errors SFP-Errors---- 266 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 299
fwPortDetailShow 2 See Also Port# Type State Dur(H:M) LFA LSY LSI PER INW CRC PSC BLP STM SRX STX SCU SVO 001 F HEALTHY 409:09 014 F HEALTHY 409:09 015 E HEALTHY 409:09 switchStatusShow Fabric OS Command Reference Manual 267 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 300
1 U_PORT 0 0 0 100 2 U_PORT 0 0 0 100 3 E_PORT 21 0 0 78 4 E_PORT 20 0 0 80 5 U_PORT 0 0 0 100 6 U_PORT 0 0 0 100 7 U_PORT 0 0 0 100 See Also portShow, switchShow 268 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 301
recognized as such. Examples To set message levels and port persistence time: switch:user> fwset --port --persistence 18 See Also fwShow Fabric OS Command Reference Manual 269 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 302
place. Operands none Examples To set alarm levels to custom values: switch:admin> fwsettocustom Committing configuration...done. See Also fwSetToDefault 270 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 303
in place. Operands none Examples To return alarm levels to default values: switch:admin> fwsettodefault Committing configuration...done. See Also fwSetToCustom Fabric OS Command Reference Manual 271 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 304
Gateway mode, only the following class thresholds are supported. F/FL Port (Copper) class threshold is supported only on Embedded platforms. TABLE 13 Access Gateway (Optical) class 7 : Alpa Performance Monitor class (continued on next page) 272 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 305
=> : (1..12) [11] 1 1 : Temperature 2 : Fan 3 : Power Supply 4 : return to previous page Select an area => : (1..4) [4] 2 1283 (21 mins) Last checked: 10:50:21 on 02/01/2000 Lower bound: Upper bound: Buffer Size: 0 C 75 C 10 Value history: 33 C Disabled? No Reference Manual 273 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 306
: current port persistence time = 18s switch:user> fwShow --disable --port Port Threshold Status 1 disabled See Also fwClassInit, fwConfigReload, fwConfigure, fwSet 274 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 307
facility. The h command displays the 20 most recent commands typed into the shell; the oldest commands are replaced as new ones are entered. Operands none Examples To display previous shell commands: switch:admin> h 1 version 2 switchshow 3 portdisable 2 4 portenable 2 5 switchshow See Also none - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 308
in place. Operands none Examples To disable the High Availability feature: switch:admin> hadisable HA is disabled See Also haEnable 276 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 309
running, but the background health diagnostic has discovered a problem with the blade. The logs should be checked to file error. HA synchronization status: "HA State synchronized" The system is currently fully synchronized. If a failover became necessary, it Reference Manual 277 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 310
:9c1/64 cp 1 static fec0:60:69bc:64:205:1eff:fe02:a197/64 FSSME registered: TRUE See Also haFailover, haShow 278 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 311
. Operands none Examples To enable the High Availability feature in the switch: switch:admin> haenable HA is enabled See Also haDisable Fabric OS Command Reference Manual 279 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 312
active and standby CPs are not synchronized or the system is not in redundant mode, the command aborts. current Admin Domain. This command is supported only on systems with dual -CP cards. The execution being run on a redundant control processor(CP) system, and this operation will cause the active CP - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 313
running, but the background health diagnostic has discovered a problem with the blade. The logs should be checked to and the failover is disruptive. This command might not be supported on non-bladed systems. The execution of this command is subject to Admin Reference Manual 281 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 314
. Examples To enable the HA state synchronization: switch:admin> hasyncstart HA State synchronization has started See Also haFailover, haShow, haSyncStop 282 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 315
be in place. Operands none Examples To disable the HA state synchronizing process: switch:admin> hasyncstop See Also haFailover, haShow, haSyncStart Fabric OS Command Reference Manual 283 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 316
To display help information for the help command: switch:admin> help help See Also diagHelp, fwHelp, licenseHelp, perfHelp, routeHelp, zoneHelp 284 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 317
removal events for blades, power supplies, fans, and sets: Object type FAN, POWER SUPPLY, and one CP switches. Object number and third lines of a record each contain one data set, preceded by its name: Factory or removal event: switch:admin> historylastshow POWER SUPPLY Unit 2 Inserted at Tue - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 318
change the history mode to first-in from rotating: switch:admin> historymode History Mode is: Rotating. See Also historyLastShow, historyShow 286 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 319
of each record contains the following: Object type FAN, POWER SUPPLY, and one CP switches. Object number Slot number for blades and unit or Unknown Brocade directors support 100 history log entries; all other platforms, which contain FRUs, support 28 entries. The Manual 287 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 320
Serial Number: 1013456800 CP BLADE Slot 6 Inserted at Tue Aug 14 13:59:50 2001 Factory Part Number: 60-0001604-02 Factory Serial Number: FP00X600128 POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 Factory Part Number: 60-0001536-02 Factory Serial Number: 1013456800 Records: 11 See - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 321
Synopsis httpcfgshow Description Use this command to display the version of the Java plug-in supported by Web Tools. This command also displays the URL from which the plug-in can be downloaded. http://java.sun.com/products/plugin See Also Fabric OS Command Reference Manual 289 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 322
if a process ID is supplied. One line is displayed per process. Fields TRACESYS 020 tracing system calls FORKNOEXEC 040 forked privileges DUMPCORE 200 dumped core SIGNALED 400 killed by a signal S Process state address of the process SZ The total size of the process in virtual memory, in - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 323
C PRI NI ADDR SZ WCHAN TTY TIME CMD 000 S 0 433 1 0 69 0 - 1283 5c64 ? 00:00:02 fabricd See Also diagHelp, routeHelp Fabric OS Command Reference Manual 291 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 324
supported least one common if one side supported by the network equipment to which it is attached might result in an inability to communicate with the system -CP systems, the supported supported by the network equipment to which it is attached may result in an inability to communicate with the system - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 325
10 Mbps / Full Duplex (yes, y, no, n): [no] n Force 10 Mbps / Half Duplex (yes, y, no, n): [no] y Committing configuration...done. See Also ifModeShow Fabric OS Command Reference Manual 293 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 326
> ifmodeshow eth0 Link mode: negotiated 100baseTx-HD, link ok MAC Address: 00:60:69:D0:24:40 See Also ifModeSet 294 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 327
to this interface. A value of 1000 indicates a 1-Gb/sec link. A value of 500 indicates a 2-Gb/sec link. delay Conventional delay incurred by a frame transmitted on this ISL. A fixed value required by the FSPF protocol Manual 295 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 328
commands received from the neighbor switch. Usually commands with an FSPF version number higher than the one running on the local switch. nHloIn Number of Hello frames received from the neighbor switch. nInvHlo that may be in place. 296 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 329
slash (/). portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, the interface = 80000 helloTo = 20000 (continued on next page) Fabric OS Command Reference Manual 297 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 330
2 interfaceShow rXmitTo nCmdAcc nInvCmd nHloIn nInvHlo nLsuIn nLsaIn attHloOut nHloOut attLsuOut nLsuOut attLsaOut nLsaOut = 5000 = 7 = 0 = 2 = 0 = 2 = 3 = 2 = 2 = 3 = 3 = 2 = 2 See Also nbrStateShow, portShow, switchShow 298 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 331
changed using configure. Only Port World Wide Name zoning is supported in interoperability mode. FC Routing services are not available in interop mode. Switches connected to edge . Please make sure the MS Platform service is disabled. Fabric OS Command Reference Manual 299 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 332
msPlMgmtDeactivate" command to disable the Platform service. The switch effective configuration will be OFF blade2 Beacon: OFF blade4 Beacon: OFF blade8 Beacon: OFF FC Router:ON FC Router BB Fabric ID:110 Index Slot Port Address Media Speed State Proto Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 333
) [output truncated] 223 8 31 04df00 -- -- Offline Disabled (Persistent) 8 ge0 id 1G Online FCIP 8 ge1 id 1G Online FCIP See Also configure Fabric OS Command Reference Manual 301 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 334
To turn off the IOD option: switch:admin> iodreset switch:admin> iodshow IOD is not set See Also iodSet, iodShow 302 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 335
none Examples To turn on the IOD option: switch:admin> iodset switch:admin> iodshow IOD is set See Also iodReset, iodShow Fabric OS Command Reference Manual 303 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 336
To display the current setting of the IOD option: switch:admin> iodshow IOD is not set See Also iodReset, iodSet 304 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 337
The command's usage varies depending on whether it is being used on a chassis-based system or nonchassis-based switch. On a chassis-based system, if no option is provided, the command prints the usage. To set the number Valid options include: Fabric OS Command Reference Manual 305 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 338
Selects the address on the blade to alter. Selects the slot to apply the command to on a chassis-based system. Examples To configure an IPv6 address on a switch or CP: switch:admin> ipaddrset -ipv6 -cp 0--add 74.1]: DHCP [Off]: on ipAddrShow 306 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 339
IP address. For chassis based systems with intelligent blades the one of the sub options. NOTE The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: -cp cp_number For dual-CP systems Manual 307 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 340
> -rule -sip -dp -proto -act < permit | deny > --delrule -rule maximum six policies in the defined configuration and one policy per IPv4 and IPv6 type in the active configuration. The active OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 341
> Activates the specified IP filter policy. IP filter policies are not enforced until they are activated. Only one IP filter policy per IPv4 and IPv6 type can be active. If there is a temporary buffer for , or a CIDR style IPv6 prefix. -dp Fabric OS Command Reference Manual 309 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 342
service name. -proto Specifies the protocol type, for example tcp or udp. -act Specifies the permit or deny action associated with this rule. -rule rule_number Adds a new rule at the given rule index number that is valid between 1 and the current maximum rule number plus one IP Protocol Dest - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 343
iscsicfg --clear initiator [-h ] iscsicfg --show initiator [-i initiator_name] [-h ] iscsicfg --abort transaction -x transaction_id [-h ] iscsicfg --show transaction [-h ] iscsicfg --clear all [-h ] iscsicfg --commit all [-f ] [-h ] Fabric OS Command Reference Manual 53-1000436-01 iscsiCfg 2 311 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 344
targets with all available FC targets in one step. If port_wwn is specified, all LUNs of that target are imported into one virtual target. If no port_wwn is CHAP and none. If CHAP is specified, then either one-way or mutual CHAP is enforced, based on the login frame from the host. --addusername tgt - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 345
iscsiCfg 2 lun dd ddset Fabric OS Command Reference Manual 53-1000436-01 --delete tgt -t target_name [-h ] Deletes a member_list has to be iSCSI entity names in a valid format. Currently, only IQN format is supported. Multiple entities may be specified as a comma-separated list. The IQN may be a - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 346
The operation completed successfully. To modify a CHAP entry associated with an existing user: switch:admin> iscsicfg --modify auth -u user1 -s newsecret 314 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 347
:00:20:37:df:8e:e3 iqn.2002 12.com.brocade:21:00:00:20:37:df:8e:e3 Operation Succeeded Fabric OS Command Reference Manual 315 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 348
. Members: iqn.2222-23.mytest1 iqn.2343-58.newtest1 iqn.2222-23.mytest3 mynewdd Defined 3 To create a DD set entry: 316 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 349
iSCSI database state for fabric: In Sync Displays switches that are capable of propagating iSCSI data base. To display the iSCSI initiators that attempted to login: switch:admin> iscsicfg --show initiator -i iqn.1991-05.com.brocade:initiator1 Fabric OS Command Reference Manual 317 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 350
.1991-05.com.brocade:initiator1 192.168.250.107 Physical Initiator. Accessible Targets 1 iqn.2000-12.brocade.com.246:tgt-1 To clear the iSCSI initiator database: switch:admin> iscsicfg successfully. fosConfig, iscsiPortCfg, iscsiSessionCfg 318 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 351
--slot 7 -unit 1 -testtype 0 Running iscsichiptest Test Complete: iscsichiptest Pass 1 of 1 Duration 0 hr, 3 min & 12 sec (0:3:12:511). passed. See Also iscsiPathTest Fabric OS Command Reference Manual 319 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 352
Use this command to display a list of iSCSI support commands, with descriptions. Operands This command has the following iscsi support commands and operands: -fclunquery [-w | -m -s isnsccfg --reregister isnsccfg --show 320 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 353
iSCSI support commands: switch:admin> iscsihelp fclunquery Display a list of LUNs of FC target(s). fosconfig Enable/disable FabOS services iscsicfg Manage/display all iscsi configuration including authentication/virtual targets/discovery domains. iscsiportcfg Manage/display iscsi protocol - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 354
2 -nframes 10 Running iscsipathtest Test Complete: iscsipathtest Pass 10 of 10 Duration 0 hr, 3 min & 1 sec (0:3:0:630). passed. See Also iscsiChipTest 322 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 355
session 1 Data digest support Disabled Header digest suppor Disabled Immediate data support No First burst length value for the list of default values. --show Displays port-level protocol parameters, statistics, and session information on the specified port. Options Manual 323 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 356
2 iscsiPortCfg NOTE This parameter only supports FC4-16IP blades in Brocade 48000 directors. geport -h Specifies the port number of a GbE port to be configured in 76356 114 29944 104 11 11 96 104 103 91 11 11 103 0 0 0 0 1 1 0 0 0 0 0 0 0 0 324 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 357
.1991-05.com.microsoft:win-iscsi.lab iqn.2002-12.com.tgt:21:00:00:04:cf:5d:cf:0e 0x400001370000 Fabric OS Command Reference Manual 325 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 358
the following operands: --clearstats Clears the counters associated with a session. --delete Deletes one or more iSCSI session(s). --show Displays the iSCSI session details. Options include: -v 512B 64KB Max outstanding R2T 1 16 326 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 359
: 0 Non FCP out PDU: 0 Non FCP out Octet: 0 See Also fosConfig, iscsiCfg, iscsiPortCfg 60s 0s 2 Off Peer 64KB On On On Fabric OS Command Reference Manual 327 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 360
.com.brocade To change a target name prefix: switch:admin> iscsiswcfg --modifygw -t iqn.2002-10.com.brocade The operation completed successfully. 328 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 361
See Also fosConfig, iscsiCfg, iscsiPortCfg iscsiswcfg 2 Fabric OS Command Reference Manual 329 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 362
name prefix: switch:admin> iscsitargetname --modify -u iqn.2002-10.com.brocade The operation completed successfully See Also fosConfig, iscsiCfg, iscsiPortCfg 330 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 363
: 2.000G bw: sp: 2.000G bw: sp: 2.000G bw: sp:-------- bw: sp:-------- bw: 4.000G 8.000G 2.000G 0.001G 0.125G See Also switchShow, trunkShow Fabric OS Command Reference Manual 331 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 364
a chassis and the port number of a GbE port in an iSCSI blade. NOTE: This parameter supports Brocade FC4-16IP blades in Brocade 48000 directors. --s server_ip Specifies the IP address in dotted-decimal : switch:admin> isnsccfg --reregister 332 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 365
isnscCfg 2 See Also Initiated re-register of iSNS objects with iSNS server To clear the IP address of iSNS server: switch:admin> isnsccfg --clear Cleared iSNS server configuration. none Fabric OS Command Reference Manual 333 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 366
All kernel diagnostics have at least one item list parameter to specify which ports 2/0, 3/0" specify the same ports on a 16-port/blade system. On that same system, "1/0, 16, 32" is not a valid list: even one on the command line overrides previous settings. 334 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 367
of the ports Fibre Channel address or with slot/port notation. For nonblade systems, the port number on the silkscreen is the area number, so the the parameter type is PT_LIST and the list type is one of those shown in the table. TABLE 15 Object OS Command Reference Manual 335 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 368
1:17m - 5:13pm 1 admin0 pts/1 3.00s 192.168.130.29 6:31pm Enter Session Number to terminate (q to quit) q See Also none 336 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 369
products. Without a license installed for such products, their services are not available. A license key is a string of enter a license, the licensed product is available immediately and the system does not need to be rebooted. An exception to this general handling Manual 337 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 370
none Examples To display license commands: switch:admin> licensehelp licenseAdd licenseIdShow licenseRemove licenseShow Add a license to this switch Show system license ID Remove a license from this switch Show current licenses See Also licenseAdd, licenseIdShow, licenseRemove, licenseShow 338 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 371
installed for such products, the services provided by these features are not available. For dual-domain systems, a single license enables both system, no inferences should be made about the relationships between them as they are subject to change independently of one Manual 339 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 372
there are more online ports than the purchased POD licenses can support. Operands This command has the following operands: --release portnumber for use in this switch: 10 port assignments are provisioned by the base switch license 5 port assignments are provisioned by the first POD license - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 373
licensePort 2 5 ports are assigned to the first POD license Ports assigned to the base switch license: 0, 1, 2, 3, 4, 5, 6, 7, 15, 16 Ports assigned to the first POD license: 8, 9, See Also licenseAdd, licenseRemove, licenseShow, licenseHelp Fabric OS Command Reference Manual 341 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 374
2 licenseRemove licenseRemove Removes the license key from the system. Synopsis licenseremove "license" Description Use this command to remove an existing key "bQebzbRdScRfc0iK" See Also licenseAdd, licenseHelp, licenseIdShow, licenseShow 342 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 375
license keys on a switch: switch:admin> licenseshow bQebzbRdScRfc0iK: Web license Zoning license SybbzQQ9edTzcc0X: Fabric license See Also licenseAdd, licenseHelp, licenseIdShow, licenseRemove Fabric OS Command Reference Manual 343 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 376
dimensionless positive number. The FSPF protocol compares the cost of various paths sec ISL, the default cost is 1000. For a 2-Gbit/sec ISL 2000 - (bandwidth of the ISL in Mbit/sec) 1-Gbit/sec ISL 1000 slotnumber For bladed systems only, specify to its slot for bladed systems. Use switchShow to list - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 377
Slot Interface Cost 2 0 500 (STATIC) 2 1 1000 2 2 500 (STATIC) 2 3 200 (STATIC) 2 4 1000 2 5 1000 2 6 1000 2 7 1000 2 8 1000 2 9 1000 2 10 1000 2 11 (E_PORT) 2000 (STATIC) 2 12 1000 2 13 1000 2 14 1000 2 15 1000 Type to continue, Q to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 378
Examples To log in as admin from the login user: switch:user> login login: admin Password:xxxxxx See Also logout 346 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 379
-D at the beginning of a line. Operands none Examples To log out from an rlogin session: switch:admin> logout See Also login Fabric OS Command Reference Manual 347 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 380
one time. The port LEDs flicker green rapidly while the test is running. The test method is as follows: Determine which ports are L_Ports. Enable ports for cabled loopback mode. Create a frame F of data size is generated based on each support only. This command is supported Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 381
" Pass 10 of 10 Duration 0 hr, 0 min & 1 sec (0:0:0:127). passed. See Also camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 349 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 382
members. Search parameters -f , -w, and -z allow searching for LSAN zones based on fabric ID, WWN of an LSAN zone member, or LSAN zone name if there is no LSAN zone information available at this FC Router. Each LSAN zone entry displays the following: Fabric ID The ID Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 383
:05:07:65:05:84:0b:83 50:05:07:65:05:84:09:0e switch# fcrFabricShow, fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, switchShow Fabric OS Command Reference Manual 351 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 384
Use this command to display an FSPF link state database record for switches in the fabric, or one domain within it. There are two types of database entries: The link state database entry, which this LSR. It is identical to the domain number. 352 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 385
= 0 uHopsFromRoot = 0 mOutIfsP[0] = 0x00010000 mOutIfsP[1] = 0x00000000 parent = 0xb5 mPathCost = 0 mHopsFromRoot = 0 Link State Record: Link State Record pointer = 0x10053d18 lsAge = 16 reserved = 0 type = 1 Fabric OS Command Reference Manual 353 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 386
= 1 The local switch has sixteen links in NB_ST_FULL state, all of them are connected to switch 2. See Also interfaceShow, nbrStateShow 354 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 387
used Mem: 123 107 Swap: 0 0 free 17178624 0 free 16 0 shared 0 buffers cached 139264 30396416 shared 0 buffers 0 cached 28 See Also saveCore Fabric OS Command Reference Manual 355 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 388
ASIC pair is exchanging frames with one port on the adjacent ASIC in only exchanging frames with one other port at a the ASIC pair. This test does not route frames from one ASIC-pair to another. Ports cabled to other ports one pattern each: 1000 bytes of CSPAT 480 bytes of RDRAM_PAT 2112 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 389
are nonzero: ENC_in, CRC_err, TruncFrm, FrmTooLong, BadEOF, Enc_out, BadOrdSet, DiscC3 Until one of the following is met: The number of frames requested is met on all selected bypass and SERDES loopback 9 Backend bypass and internal loopback Fabric OS Command Reference Manual 357 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 390
only used for Bloom and Condor ASIC-based products, for which this parameter controls admin> minicycle --slot 1 -lb_mode 2 Running minicycle One moment please ... Path 0 ... Spinning ... Path 1 Spinning ... Test Complete: minicycle Pass 1 of 1 358 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 391
port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One moment please ... Path 0 ... Spinning ... Path 1 ... skipped. Path 2 ... skipped. Path 3 ... skipped. RXQ_RAM_PERR Fabric OS Command Reference Manual 359 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 392
the Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 360 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 393
not intended for normal user operation and is available to provide supplemental information during system debug. Operands The operands are as follows: slotnumber/asicpair Specifies the index of the ,15) (fe,14) (fe,13) (fe,12) See Also none Fabric OS Command Reference Manual 361 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 394
Commit Service(RCS) Supported. Bit 9: Access Gateway Registration/Discovery Supported. Bit 10: Administrative Domains(AD) Supported. Others: Reserved. Done. See Also msConfigure, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable, msTdReadConfig 362 Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 395
default), MS is available to all systems connected to the fabric. By populating the MS ACL with one or more World Wide Names (WWNs based on its port/node WWN If the MS ACL is changed by adding or deleting WWNs, an additional prompt is given asking if the MS ACL should be saved to nonvolatile storage - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 396
2 msConfigure done ... See Also msCapabilityShow, msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable, msTdReadConfig, secPolicyShow 364 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 397
:60:69:20:15:79 10:00:00:60:69:20:15:75 See Also msCapabilityShow, msConfigure, msPlatShowDBCB, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate Fabric OS Command Reference Manual 365 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 398
that may be in place. Operands none Examples To display the MS platform service database control block: switch:admin> msplatshowdbcb Domain Worldwide Name Retry Count Exchange msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate 366 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 399
platform database: switch:admin> msplcleardb MS Platform Service is currently enabled. This will erase MS Platform Service Database in the entire fabric. Would you like operation in progress..... *Completed clearing MS Platform Service Database!! See Also msCapabilityShow, msConfigure, msPlatShow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 400
changes to nonvolatile storage of each switch. After successful activation, all switches in the fabric boot with the MS platform service enabled. By default, the MS platform service is disabled. Before issuing, run the msCapabilityShow command to verify all switches in the fabric support MS platform - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 401
service for each switch in the fabric and commits the change to nonvolatile storage. When security is enabled, this command can be issued only from the primary FCS switch. This command is supported deactivate MS Platform Service in progress...... *Completed deactivating MS Platform Service in the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 402
power cycles and reboots. If the "ALL" operand is used, this command attempts to disable the topology discovery service support RNID ELS. Operands The optional operand is as follows: "ALL" Disables the MS topology discovery service MS Topology Discovery Service in progress.... Discovery Service in - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 403
topology discovery service on all command is supported only in support RNID ELS. Operands This command has the following operand: "ALL" Enables the MS topology discovery service service on the local switch only: switch:admin> mstdenable Request to enable MS Topology Discovery Service Service - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 404
this command to check whether or not the management server topology discovery service is enabled. The execution of this command is subject to Admin Operands none Examples To display the status of the topology discovery service: switch:admin> mstdreadconfig *MS Topology Discovery is enabled. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 405
Use this command to display all local IPv4 or IPv6 addresses associated with the status of the system and the login session details. The login session gives details of the following: CP/switch (or .123.123) Active Redundant See Also version Fabric OS Command Reference Manual 373 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 406
neighbor is in NB_ST_FULL state. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to display, followed by a slash (/). 16 2 48 NB_ST_FULL See Also interfaceShow 374 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 407
Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted 17 switch:admin> nbrstatsclear 1/0 switch:admin> interfaceshow 1/0 idbP = 0x10050a38 Fabric OS Command Reference Manual 375 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 408
= 500 (output truncated) nCmdAcc = 0 nInvCmd = 0 nHloIn = 0 nInvHlo = 0 nLsuIn = 0 nLsaIn = 0 attHloOut = 0 nHloOut = 0 attLsuOut = 0 nLsuOut = 0 attLsaOut = 0 nLsaOut = 0 See Also interfaceShow, portShow, switchShow 376 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 409
can be used to match the real device's data. WWN must have eight colon-separated fields, each consisting of one or two hexadecimal digits between 0 and ff, with no spaces. PID must begin with 0x or 0X; otherwise, 7e;20:00:00:04:cf:9f:26:7e; 0 Fabric OS Command Reference Manual 377 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 410
device information matching the given no match: switch:user> nodefind abcd No device found. See Also aliShow, nsAllShow, nscamShow, nsShow 378 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 411
is not detected Initiator An SCSI initiator Target An SCSI target Initiator+Target Both an SCSI initiator and an SCSI target Fabric OS Command Reference Manual 379 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 412
:00:60:69:01:44:22 Permanent Port Name: 21:00:00:fa:ce:00:21:e1 Aliases: MyAlias1 MyAlias2 380 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 413
:ad:bc:04:6f:70 Device type: Physical Target Aliases: The Local Name Server has 6 entries } See Also nsAllShow, nsShow, switchShow Fabric OS Command Reference Manual 381 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 414
type device 4 , 5 = FC-IP type device Other FC-PH types are displayed in the format "x ports supporting FC4 code," where x is the number of ports of a type and code is the FC-PH type code. 2 FC-IP Ports } See Also nsShow, switchShow 382 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 415
for N_Port, NL for NL_Port Pid The 24-bit Fibre Channel address COS A list of classes of service supported by the device PortName The device's port World Wide Name (WWN) NodeName The device's node WWN the fabric: switch:admin> nscamshow Fabric OS Command Reference Manual 383 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 416
entry for 4 state rev owner known v320 0xfffc01 Device list: count 0 No entry is found! See Also nsAllShow, nsShow, switchShow 384 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 417
N for N_Port, NL for NL_Port. PID 24-bit Fibre Channel address. COS List of classes of service supported by device. PortName Device port World Wide Name (WWN). NodeName Device node WWN. TTL Time-to-live events detected by the fabric. Fabric OS Command Reference Manual 385 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 418
Server has 2 entries } To display local name server information with "-r" option. switch:admin> nsshow -r { Type Pid COS PortName NodeName SCR 386 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 419
Index: 14 Share Area: No Device Shared in Other AD: No Redirect: No The Local Name Server has 2 entries } nsAllShow, switchShow Fabric OS Command Reference Manual 387 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 420
for N_Port, NL for NL_Port Pid The 24-bit Fibre Channel address COS A list of classes of service supported by the device PortName The device's port World Wide Name (WWN) NodeName The device's node WWN Permanent :00:00:00:c9:26:0e:ae; 3 388 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 421
: ix360_131_196p5 Pid: 0xe07d00 Aliases: hds9200_6p4 hds9200_6p4 Port: 14 Pid: 0xb00e00 Aliases: dl360_130251a dl360_130251a Zoned Members: 2 devices Pid: 0xb00e00 Aliases: dl360_130251a dl360_130251a Fabric OS Command Reference Manual 389 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 422
; Aliases: trimm32a_7 Pid: 0xb01fb2; Aliases: trimm32a_8 Pid: 0xdc2800; Aliases: Totally 9 unzoned devices in the fabric. See Also cfgShow, nscamShow, nsShow 390 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 423
you are changing another user's password, the target account's AD member list must be a subset of your account's AD member list. Fabric OS Command Reference Manual 391 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 424
stable storage. Password saved to stable storage successfully. Diagnostics When failures are detected, the subtext might report one or not specified a user name that is a valid recognized user name on the system. Permission denied You do not have permission to change the login name or password - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 425
the minimum required number of punctuation characters. Password matches one of the previous passwords You have entered a password that matches one of the previous passwords. You cannot reuse the old for more information. login, logout, passwdCfg Fabric OS Command Reference Manual 393 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 426
policies. When secure mode is enabled, passwdCfg is not supported. Use --set to configure the following password policies: . When a password fails more than one of the strength attributes, an error is reported for only one of the attributes at a time. The Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 427
characters. The default value is 8. The total of -lowercase, -uppercase, -digits, -punctuation must be less than or equal to -minlength value. Fabric OS Command Reference Manual 395 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 428
login equals the "passwdcfg.lockoutthreshold", the account gets locked for the "passwdcfg.lockoutduration" duration. The particular account is unlocked manually using userconfig --change -u by root/factory/security admin/admin users or it will automatically get unlocked after - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 429
each contiguous character differs by one. The ASCII value for one or more of the following error messages displays: Permission failure The user is not permitted to execute the command. Command not supported passwdCfg is not supported when secure mode is enabled. Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 430
must be between 1 and 40 sequence value out of range The -sequence value must be between 1 and 40 passwd, userConfig 398 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 431
support this feature. If the advanced performance tuning (APT) policy in effect on the intermediate switches is not a port-based hop 0, this is src_portnumber. For bladed systems, this is specified as the port index; protocol. Only applicable if the output link is currently recognized by FSPF - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 432
pathInfo frame has to traverse to reach the destination. Therefore, the path might be different from the one used by actual traffic. The source route is expressed as a sequence of switches, a sequence of or the domain ID of the next hop. 400 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 433
default is embedded port (-1), or if a destination port is specified that is not active. For bladed systems, the destination is specified as the area; otherwise, it is the port. "-r" Display reverse path in domain rather than output port. Fabric OS Command Reference Manual 401 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 434
BW Cost 0 E 9 (web226) 2 1G 1000 1 3 10 (web229) 8 1G 1000 2 8 8 (web228) 9 1G 1000 3 6 91 (web225) E - - 2294316 2119951 2121767 Frames 20025929 54999 162338 56710 Errors - 4 - 0 (continued on next page) 402 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 435
pathInfo 2 Hop In Port Domain ID (Name) Out Port BW Cost 2 14 8 (web228) E - - (output truncated) See Also portStatsShow, switchShow Fabric OS Command Reference Manual 403 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 436
The panic dump file contains information that might be useful to determine the cause of the system panic. When executed without any arguments, this command displays output from the latest panic dump file ) See Also portLogDump, saveCore 404 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 437
Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M which the monitor is to be added, relative to its slot for bladed systems. Use switchShow for a list of valid ports. SourceID Specify the 3-byte Manual 405 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 438
1/2 "0x050200" "0x1182ef" End-to-End monitor number 0 added. See Also perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor, perfClearEEMonitor, perfDelEEMonitor, perfShowEEMonitor 406 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 439
execution of this command, a monitor number is displayed. The monitor number is provided for manipulation of these filter-based performance monitors. The optional user-defined alias is also displayed, if one is specified. All valid monitor numbers and user-defined aliases can be displayed with the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 440
based performance monitors. The optional user-defined alias is also displayed, if one Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), to be added, relative to its slot for bladed systems. Use switchShow for a list of valid ports. Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 441
based performance monitors. The optional user-defined alias is also displayed, if one Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), to be added, relative to its slot for bladed systems. Use switchShow for a list of valid ports. Manual 409 53- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 442
based performance monitors. The optional user-defined alias is also displayed, if one Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), to be added, relative to its slot for bladed systems. Use switchShow for a list of valid ports. Manual 53-1000436- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 443
based performance monitors. The optional user-defined alias is also displayed, if one supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Bloom-based following operands: slotnumber For bladed systems only, this operand specifies the slot Manual 411 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 444
to include spaces. This operand is optional. By default, the alias is an empty string. . Examples To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a port: switch:admin> perfaddusermonitor 1/4 "4, 0xff, 0x22; 12, 0xff, 0x01" User monitor #0 added - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 445
execution of this command, a monitor number is displayed. The monitor number is provided for manipulation of these filter-based performance monitors. The optional user-defined alias also is displayed, if one was specified. All valid monitor numbers and user-defined aliases can be retrieved with the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 446
This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and configuration cleared from FLASH. See Also perfCfgRestore, perfCfgSave 414 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 447
command. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE restored from FLASH. See Also perfCfgClear, perfCfgSave Fabric OS Command Reference Manual 415 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 448
be saved across power cycles. The When there are more than 512 monitors in the system, monitors are saved to the flash in the Tools will not be saved in persistent memory. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 449
a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror monitor is to be added, relative to its slot for bladed systems. Use switchShow for a list of valid ports. ALPA Specify the Manual 417 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 450
a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror is to be cleared, relative to its slot for bladed systems. Use switchShow for a list of valid ports. monitorId Specify OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 451
all filter-based monitors clearing. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual the monitor is to be cleared, relative to its slot for bladed systems. Use switchShow for a list of valid ports. monitorId Specify the monitor - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 452
one Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M ( command has the following operands: slotnumber For bladed systems only, this operand specifies the slot number of the OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 453
based performance monitor from a port, or all such monitors associated with a port. This command requires a Brocade Advanced Performance Monitoring license. This command is not supported is to be deleted, relative to its slot for bladed systems. Use switchShow for a list of valid ports. monitorid - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 454
/filter-based/ISL monitors Show end-to-end/filter-based/ISL monitors Set overall mask for E-to-E monitors Get ALPA CRC count by port and ALPA Show user-defined end-to-end monitors Show filter-based monitors Show the current end-to-end mask See Also none 422 Fabric OS Command Reference Manual 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 455
a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror one of EE (end-to-end), FLT (filter-based), or ISL (interswitch link). These values are case sensitive. This operand is required. slotnumber For bladed systems - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 456
will clear ISL monitor on port 1, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor, perfMonitorShow 424 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 457
Destination Port ID Owner_app Telnet or Web Tools Owner_ip_addr The IP address of the originator the traffic at the specified interval. For filter-based monitors, this command can display (if no one for a standalone ISL, more for trunks) Fabric OS Command Reference Manual 425 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 458
Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M one of EE (end-to-end), FLT (filter-based), or ISL (interswitch link). These values are case-sensitive. slotnumber For bladed systems Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 459
0x0000000000002208 192.168.169.40 6 SCSI_WR WEB_TOOLS 0x000000000000033a 192.168.169.40 To display filter-based monitor on a port at an interval of every 6 seconds: switch:admin> perfmonitorshow --class end monitor(s) defined on port 53. Fabric OS Command Reference Manual 427 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 460
0x0000000000000000 0x0000000000000000 N/A perfShowEEMonitor, perfShowFilterMonitor, perfMonitorClear, perfAddEEMonitor, perfAddIPMonitor, perfAddRWMonitor, perfAddReadMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor 428 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 461
field must be masked together, to support the FC4-48 blade. On this blade, one bit of the AL_PA ID address a port. The default EE mask value upon power-on is already set. When ISL monitoring is systems. Use switchShow for a list of valid ports. Fabric OS Command Reference Manual 429 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 462
, n): [no] y The EE mask on port 6 is set and EE Monitors on this port are deleted See Also perfAddEEMonitor, perfShowEEMonitor 430 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 463
of one or supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems Manual 431 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 464
Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M the monitor is to be displayed, relative to its slot for bladed systems. Use switchShow for a list of valid ports. interval Specify an interval, Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 465
0x0000000000000000 N/A 0x0000000000000000 N/A 0x0000000000000000 N/A 0x0000000000000000 192.168.169.40 0x0000000000000000 192.168.169.40 Some platforms do not support counting CRC errors, and therefore the CRC error counts is not displayed for those platforms. See Also perfAddEEMonitor - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 466
to display all the filter-based monitors defined on the use perfMonitorShow instead. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port is to be displayed, relative to its slot for bladed systems. Use switchShow for a list of valid ports. interval Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 467
port: switch:admin> perfshowfiltermonitor 2/5 There are 7 filter-based monitors defined on port 21. KEY ALIAS OWNER_APP FRAME_COUNT perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor Fabric OS Command Reference Manual 435 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 468
command is deprecated; use perfMonitorShow instead. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M ( which the monitor is to be displayed, relative to its slot for bladed systems. Use switchShow for a list of valid ports. Examples To display the Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 469
perfShowPortEEMask 2 RxSID ALPA: on RxDID Domain: on RxDID Area: on RxDID ALPA: on See Also perfAddEEMonitor, perfDelEEMonitor, perfSetPortEEMask, perfShowEEMonitor Fabric OS Command Reference Manual 437 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 470
displayed: switch:admin> pkicreate Warning !! Switch is in secure mode. Cannot create new Pki Objects. Exiting... See Also pkiRemove, pkiShow 438 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 471
displayed: switch:admin> pkiremove This Switch is in secure mode. Removing Pki objects is not allowed. Exiting... See Also pkiCreate, pkiShow Fabric OS Command Reference Manual 439 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 472
objects: switch:admin> pkishow Passphrase : Exist Private Key : Exist CSR : Exist Certificate : Empty Root Certificate: Exist See Also pkiCreate, pkiRemove 440 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 473
policies. You can configure a maximum of 32 Internet key exchange (IKE) and 32 Internet protocol security (IPSec) policies. Each FCIP tunnel is configured separately and might have the same or as it uses 2048 bit values, but most secure. Fabric OS Command Reference Manual 441 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 474
:admin> policy --show ipsec all IPSec Policy 2 Authentication Algorithm: SHA-1 Encryption: AES-128 SA Life (seconds): 28800 IPSec Policy 29 442 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 475
): 28800 To delete a policy: switch:admin> policy ike --delete 10 The policy has been successfully deleted. See Also portCfg, portCfgShow, portShow Fabric OS Command Reference Manual 443 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 476
. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to display, followed Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display the AL_PAs of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 477
to the port based on the estimated mode, certain systems might reserve in long distance mode), the fixed distance displays based on the port speed, for instance: 1G echoed back to the switch. The supported distance measurement is up to 500 Km the connecting port does not support LD mode, is shows - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 478
that may be in place. Operands The operands are as follows: slotnumber For bladed systems only, specifies the slot number of the port group to display, followed by a 18 - - 0 - - 19 - - 0 - - 54 See Also portCfgLongDistance 446 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 479
portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, information for all ports is displayed. Ports that support shared areas are divided into two ports: primary and secondary ports. Primary - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 480
DID used SID entries DID entries 34 3 1 350400 2b2200 2b1200 220400 SID Free, DID Free: (61, 511) See Also switchSho 448 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 481
A range of ports in the same slot Actions This command supports the following actions: arp -- Address resolution protocol (ARP) entry. Usage: portcfg arp [slot/][ge]port 10. If tape pipelining is enabled, minimum value supported is 80. Fabric OS Command Reference Manual 449 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 482
is 8. If tape pipelining is enabled, default value is calculated based on the minimum retransmit time to ensure that the TCP connection same port. Jumbo frames will not be supported on secure tunnels. Only a single route is supported on an interface with a secure tunnel. modify Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 483
enabled, default value is calculated based on the mininum retransmit time to device that is zoned with this one. By default, RSCN suppression is for rscnsupr are: slot For bladed systems only, specifies the slot number of the to its slot for bladed systems. For GbE ports, the ports are numbered - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 484
protocol from 1500 to 8256. For v5.3.0, valid MTU size for Brocade 7500 or an FR4-18i blade are configured, relative to its slot for bladed systems. Use switchShow for a list of valid disables FC Fastwrite between two Brocade 7500 routers or two Brocade 48000 directors with Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 485
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON EX Port Mirror Port .. .. .. .. ON Fabric OS Command Reference Manual 453 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 486
ON ON ON ON ON EX Port Mirror Port where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 portCmd, configure, portShow, switchShow 454 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 487
may be in place. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to display, followed by a slash , portCfgPersistentEnable, portCfgShow, portCfgSpeed, portCfgTrunkPort Fabric OS Command Reference Manual 455 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 488
made by this command are persistent across switch reboots or power cycles. NOTE The execution of this command is subject of the port to be configured, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. mode Specify 1 OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 489
. The fabric ID must be the same for every router port connected to the same edge fabric, and different fabrics have been assigned the same fabric ID, one of them is disabled due to a fabric ID R_A_TOV used for port negotiation. Valid values are 2000 120000. This operand is only applicable if the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 490
used for port negotiation. Valid values are 1000 60000. This operand is only applicable 00:60:69:c0:05:8a Fabric Parameters: Auto Negotiate R_A_TOV: 9000(N) E_D_TOV: 2000(N) Edge fabric's primary wwn: N/A Edge fabric's version stamp: N/A To set the OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 491
portCfgEXPort 2 See Also switch:admin> portcfgexport 2/0 -t 2 portCfgVEXPort, portDisable, portEnable, portShow, portCfgDefault, fcrbcastconfig Fabric OS Command Reference Manual 459 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 492
made by this command are persistent across switch reboots or power cycles. The execution of this command is subject to number of the port to be configured, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. mode Specify a value Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 493
NOTE The long distance modes L0, L1, and L2 are no longer supported in v5.3.0. • Trunk port • Long distance • VC link init , zoning will drop frames. This feature is persistent across reboots and power cycles. Use the portCfgShow command to view whether ISL R_RDY mode is Manual 461 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 494
by a slash (/). portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. mode Specify 1 to enable ISL R_RDY mode. Specify 0 Also configure, portCfgLongDistance, portCfgShow 462 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 495
reboots or power cycles. This command requires a Brocade Extended Fabrics license. The value of distance_level can be one of the full-size frame buffers are reserved for data traffic, depending on the desired distance value provided with the portCfgLongDistance command. For Bloom1-based systems, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 496
. This feature is not backward compatible with firmware versions that do not support it. If a port is configured as a long distance port, the the following operands: slotnumber Specifies the slot number, for bladed systems only. The slot number must be followed by a slash Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 497
switch port 63 to support a 100 Km link and be initialized using long-distance link initialization protocol: switch:admin> portcfglongdistance Fbsy: 0 See Also configure, portCfgISLMode, portCfgTrunkPort, portCfgShow, portShow, switchShow Fabric OS Command Reference Manual 465 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 498
place. Operands The operands are as follows: slotnumber For bladed systems only, specify the slot number of the port to be optional; if omitted; the default value of 0 is used. Private devices are supported only on Brocade 3250, 3850, and 3900 and directors with FC2-16 and Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 499
4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Locked L_Port ON Private L_Port Locked Loop HD Loop Fairness See Also configure, portShow, switchShow Fabric OS Command Reference Manual 467 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 500
N_Port will automatically come online if it is connected to the enterprise fabric switch that supports NPIV. The N_Port must have NPIV capability enabled. NOTE NPIV capability should be enabled Persistent Disable : See Also portCfgShow 468 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 501
based ports. It can be selectively enabled or disabled on switch ports using this command. NPIV HAFor a redundant control processor (CP) system made by this command are persistent across switch reboots and power cycles. Use the portCfgShow command to display whether NPIV is Manual 469 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 502
AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 See Also To disable NPIV functionality on a port: switch:admin> portcfgnpivport 1/3 0 configure, portCfgDefault, portCfgShow 470 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 503
port. The switch still runs power-on diagnostics and initializes a persistently to configure, relative to its slot for bladed systems. Use switchShow to display a list of valid , portEnable, portCfgPersistentEnable, portShow, switchShow Fabric OS Command Reference Manual 471 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 504
ports remain enabled across power cycles, switch reboots, may reconfigure. If this port is connected to one or more devices, the devices can now communicate This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 505
command to display specific FCIP parameters configured for a gigabit Ethernet port, such as address resolution protocol (ARP) entries, IP routes, IP interfaces, FCIP tunnels, and mode. Information varies with is set by the portCfgEPort command. Fabric OS Command Reference Manual 473 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 506
based ports. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: arp Displays address resolution protocol systems. 1000 Kbps (0.001000 Gbps) SACK on 474 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 507
:37:00:20 Compression off Fastwrite off Tape Pipelining off Uncommitted bandwidth, minimum of 1000 Kbps (0.001000 Gbps) SACK on Min Retransmit Time 100 Keepalive Timeout 10 Max Retransmissions , portCfgNPIVPort, portCfgSpeed, portCfgTrunkPort Fabric OS Command Reference Manual 475 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 508
and is persistent across switch reboots or power cycles. This configuration cannot be set the following operands: slotnumber For bladed systems only, specify the slot number of port. This operand is required. Valid values are one of the following: 0 Autosensing mode. The port Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 509
slash (/). portnumber Specify a port number to be configured, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. mode Specify 1 to enable this port Also portCfgShow, portShow, switchCfgTrunk, switchShow Fabric OS Command Reference Manual 477 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 510
The fabric ID must be the same for every router port that is connected to the same edge different fabric IDs, one of them will be disabled due to Fabric ID port negotiation (E_D_TOV*2000 - 12000). -e edtov Specify the E_D_TOV used for port negotiation (1000 - R_A_TOV/2). -d Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 511
: 10:00:00:60:69:c0:05:8a Fabric Parameters: Auto Negotiate R_A_TOV: 9000(N) E_D_TOV: 2000(N) Edge fabric's primary wwn: N/A Edge fabric's version stamp: N/A To set the fabric ID of Also portCfgEXPort, portDisable, portEnable, portShow Fabric OS Command Reference Manual 479 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 512
size] Description Use this command to invoke the end-to-end IP path performance (ipperf) characterization feature or to ping, or trace route to a destination IP host from an intelligent GbE port. Currently we do not support for bladed systems only, ge the IP router path. -S Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 513
path performance based on the support for aging. During black hole PMTU detection the BW, WBW, Loss and PMTU values printed may not be accurate. --ping [slot/]ge port -s src_ip -d dst_ip [-n num_requests] [-q service_type] [-t ttl] [-w wait_time] [-z size] Pings a destination IP address from one - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 514
first_ttl] [-q type_of_service] [-w timeout] [-z size] Traces the IP router hops used to reach the host dst_ip from one of the source IP interfaces on the hops. This operand is optional. -q service_type Specifies the type of service in the traceroute request. The default is 0 and service_type must be - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 515
-- --ipperf; otherwise, if you use ipperf without the double-dash (--), a message displays indicating that ipperf is deprecated. See Also portCfg, portShow, Fabric OS Command Reference Manual 483 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 516
values are 1 to 5. Examples To set debug level and verbose level of port modules: switch:admin> portdebug 3 4 See Also dbgShow 484 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 517
be in place. Operands This command has the following operand: slotnumber For bladed systems only, specify the slot number of the port to be configured, followed by a port number to be disabled, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 518
disabled, the port's blade is not fully enabled (faulted, powered off, or disabled), or if the port itself is persistently has the following operand: slotnumber For bladed systems only, specify the slot number of the port relative to its slot for bladed systems. Use switchShow to display a list - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 519
contains one output line per port and shows error counters in ones, thousands 0 2 0 0 13: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 14: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 15: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 16: 0 0 - 0 0 0 0 - 0 - - - - 17: 0 0 - 0 0 0 0 - 0 - - - - - Fabric OS Command Reference Manual 487 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 520
25: 0 0 - 0 0 0 0 - 0 - - - - 26: 0 0 - 0 0 0 0 - 0 - - - - 27: 0 0 - 0 0 0 0 - 0 - - - - 28: 0 0 - 0 0 0 0 - 0 - - - - 29: 0 0 - 0 0 0 0 - 0 - - - - 30: 0 0 - 0 0 0 0 - 0 - - - - 31: 0 0 - 0 0 0 0 - 0 - - - - - See Also portShow, portStatsShow 488 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 521
PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT 4 15 Online In_Sync PRESENT ACTIVE E_PORT G_PORT LOGIN LED ACCEPT See Also portShow, switchShow Fabric OS Command Reference Manual 489 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 522
, refer to the itemList command. Examples To test port LEDs: switch:admin> portledtest -ports 1/1-1/5 passed. See Also itemList, switchDisable, switchEnable 490 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 523
none Examples To clear the port log: switch:admin> portlogclear switch:admin> portlogshow port log is empty See Also portLogDump, portLogShow Fabric OS Command Reference Manual 491 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 524
. Operands none Examples To display the current port log configuration: switch:admin> portlogconfigshow max portlog entries = 8192 See Also portLogResize 492 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 525
restrictions that may be in place. Operands None. Examples To display the port log facility: switch:admin> portlogdisable See Also portLogEnable Fabric OS Command Reference Manual 493 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 526
full explanation of the information displayed by this command, refer to the Fabric OS Administrator's Guide. The execution of this command is subject to Admin Domain restrictions that may be in place 5 See Also portLogClear, portLogShow, upTime 494 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 527
to 8,192 entries. Refer to portLogConfigShow to display the current port log size. Once the log is full, the newest log entries delete the oldest port log is disabled Refer to the Fabric OS Administrator's Guide for more information. The execution of this command is subject Manual 495 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 528
that may be in place. Operands None. Examples To enable the port log facility. switch:admin> portlogenable See Also portLogDisable 496 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 529
err 0 32 frame 0 33 msRemQ 0 34 msRemR 0 35 nsRemQ 0 36 nsRemR 0 37 rscn 0 38 state 0 39 xalloc 0 (continued on next page) Fabric OS Command Reference Manual 497 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 530
0 46 payload 0 47 zone 0 48 cmd 0 49 event 0 50 msg 0 51 switch 0 52 ficonq 0 53 routing 0 See Also portLogTypeDisable, portLogTypeEnable 498 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 531
size for this login. cos Class of Services supported. This can be a combination of the following bits: 4 Class 2 is supported. 8 Class 3 is supported to its slot for bladed systems. Use switchShow to display a list in this case, revealing one FLOGI (type fe) and Manual 499 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 532
clear or 1 to set the debug_pdisc_flag. Examples To set the pdisc_flag: switch:admin> portlogpdisc 1 PDISC log setting = 1 See Also none 500 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 533
Domain restrictions that may be in place. Operands none Examples To enable the port log: switch:admin> portlogreset See Also none Fabric OS Command Reference Manual 501 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 534
log to specified number of entries. If num_entries is less than the already configured port log size, no change is effected. The execution of this command is subject to Admin Domain restrictions portlogresize 12288 See Also portLogConfigShow 502 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 535
display the current port log size. Once the log is based response is transmitted errlog A message is added to the error log loopscn A loop state change notification is posted create A task is created debug A debug message nbrfsm Neighbor state transition Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 536
by the event. Displays a value defined by the event as follows: I/O control command code Frame payload size New state (see state codes below) New physical state (see pstate codes below) The CT-subtype: = disable ports State (refer to state codes next) Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 537
valid (0001 means argument 1 is valid, 0003 means arguments 1 and 2 are valid). [B] the CT-based service command code. Argument 1 is the first word of the CT payload, if applicable (as specified in [A]). various fields are as follows: state Fabric OS Command Reference Manual 505 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 538
-initialization Speed Negotiation States INIT Start negotiation NM Negotiate master WS Wait for signal NF Negotiation follow NC Negotiation complete 506 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 539
explanation of the information displayed by this command, refer to the Fabric OS Administrator's Guide. The execution of this command is subject to Admin Domain restrictions that may be ,0e090908 See Also portLogClear, portLogDump, upTime Fabric OS Command Reference Manual 507 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 540
:28.483 tFabric ioctl 14 a1 0,0 08:35:28.483 tFabric scn 14 5 (output truncated) See Also portLogClear, portLogShow, upTime 508 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 541
by running portLogEventShow. Examples To disable event 2 from reporting to the port log: switch:admin> portlogtypedisable 2 See Also portLogDisable, portLogEventShow, portLogTypeEnable Fabric OS Command Reference Manual 509 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 542
by running portLogEventShow. Examples To enable event 2 to report to the port log: switch:admin> portlogtypeenable 2 See Also portLogEventShow, portLogTypeDisable 510 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 543
this test does not include the media or the fiber cable. Only one frame is transmitted and received at a time. No external cable is Set all ports for parallel loopback. Create a frame F of maximum data size (2,112 bytes). Transmit frame F through port N. Pick up the frame Manual 511 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 544
Specify the speed mode for the test. This parameter is used only with Bloom and Condor ASIC-based products, where it controls the speed at which each port is operated. For 1 Gbit/sec-only 1 -lb_mode 1 Running Port Loopback Test .... passed. 512 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 545
STATS TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual 513 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 546
terminating from this FL_Port. Port mirroring does not support ALPA granularity port mirroring. A mirror connection can that is "Defined" has not been hardware configured due to at least one port not being online. A connection that is "Enabled" has been Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 547
The port mirroring feature is only supported on the following platforms: Brocade port on which the mirror port is located, relative to its slot for bladed systems. Use switchShow for a list of valid ports. This port number will be the 0x240400 Fabric OS Command Reference Manual 515 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 548
mirror connection(s) configured: 2 Mirror_Port SID DID State 10/12 0x791800 0x791900 Defined 10/15 0x791a00 0x799300 Enabled See Also portCfgShow 516 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 549
configurable port attributes, port name persists across reboots and power cycles. It is not affected by configDefault command, port number to be configured, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. name Specify Reference Manual 517 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 550
ports on the switch. Data displays in 8 or 16 columns, one column per port plus one column that displays the total for these ports. Results display every second slot 2: 0 178m 0 0 812k 0 0 0 43m 0 87m 0 272k 0 330 0 310m See Also portStatsShow 518 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 551
all ASIC SRAMs and registers are tested. The command is supported only on Brocade 200E, 3250, 3850, 3900, 4100 By default, all subtests are performed. Valid mask values include one or more of the following: 0x2 Skip retry register test. passed. Fabric OS Command Reference Manual 519 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 552
portRegTest Diagnostics When this command detects failure(s), the test might report one or more of the following error messages: BUS_TIMEOUT REGERR REGERR_UNRST See Also , cmiTest, itemList, portLoopbackTest, spinSilk, sramRetentionTest 520 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 553
The arrangements of ports on an ASIC pair is specific to the system type. For any active port, this table contains at least one entry, which routes unicast frames destined to the embedded port (value table: 60: 0x8000 (vc=2) 63: 0x1000 (vc=5) Fabric OS Command Reference Manual 521 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 554
2 portRouteShow broadcast routing table: 0x10000 See Also bcastShow, fabricShow, switchShow, topologyShow, uRouteShow 522 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 555
display the following general information, followed by three columns of counters. NOTE In an AD context, if one of the L-ports or NPIV ports is a part of the current AD, the complete device information portPhys Physical port states include: Fabric OS Command Reference Manual 523 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 556
phantom domain and the WWN of the xlate phantom domain . The xlate phantom domain connected at this port is in the same fabric as the router and represents the edge fabric connected to the EX_Port. 524 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 557
are configured both on the router and the edge switch, the security type is displayed as "DH_CHAP". DH-CHAP is the only supported authentication type. DH Group If column also displays the number of loop initialization protocols (LIPs) received, number of LIPs transmitted, and the last - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 558
Displays GbE port WWN and iSCSI Sessions. mode Displays the mode of the GbE port. slot For bladed systems only, specify the slot number of the port to be configured, followed by a slash (/). [ge] : Distance: normal portSpeed: N2Gbps 526 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 559
5 WWN: 10:00:00:05:1e:34:02:04 Fabric params: R_A_TOV: 10000 E_D_TOV: 2000 PID fmt: core Authentication Type: None Hash Algorithm: N/A DH Group: N/A Edge fabric's primary : 2 Loss_of_sig: 4 Protocol_err: 0 Invalid_word: 0 Frjt: 0 Fbsy: 0 Fabric OS Command Reference Manual 527 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 560
:00:05:1e:37:00:20 Compression off Fastwrite off Tape Pipelining off Uncommitted bandwidth, minimum of 1000 Kbps (0.001000 Gbps) SACK on Min Retransmit Time 100 Keepalive Timeout 10 Max Retransmissions 8 DSCP Marking .255.107 255.255.255.0 1500 528 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 561
05:1e:37:00:20 Compression off Fastwrite off Tape Pipelining off Uncommitted bandwidth, minimum of 1000 Kbps (0.001000 Gbps) SACK on Min Retransmit Time 100 Keepalive Timeout 10 Max Retransmissions 8 , portLoginShow, portName, switchShow Fabric OS Command Reference Manual 529 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 562
/sec). stat64_rateTxByte Tx Byte rate (bytes/sec). stat64_rateRxByte Rx Byte rate (Bytes/sec). stat64_rateTxPeakByte Tx peak Byte rate (Bytes/sec). 530 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 563
restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to be displayed, followed by a slash bad end-of-frame (continued on next page) Fabric OS Command Reference Manual 531 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 564
: 4-byte words transmitted 0 bottom_int : 4-byte words transmitted stat64_rxClass1Frames 0 top_int : 4-byte words transmitted 0 bottom_int : 4-byte words transmitted See Also portStatsClear, portStatsShow 532 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 565
ALPA-based CRC monitor, End-to-End monitor, and Filter-based For platforms with a Bloom-based ASIC, the command clears the the following operands: slotnumber For bladed systems only, specify the slot number of cleared, relative to its slot for bladed systems. Use switchShow to display a list of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 566
times zero tenancy occurred. The execution of this command is subject to Admin Domain restrictions that may be in place. 534 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 567
[ge]portnumber Specifies a port number to be configured, relative to its slot for bladed systems. Specify the optional ge option to display the GbE port hardware statistics. Use switchShow to display ge_stat_tx_frms 0 GE transmitted frames Fabric OS Command Reference Manual 535 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 568
packets ip_in_mcast_pkts 0 IP received multicast packets ip_err_crc ip_err_hdr_cksum ip_err_tcp_data_chksum 0 IP CRC Errors 0 IP Checksum Errors 0 IP TCP Data Checksum Errors 536 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 569
See Also portErrShow, portShow portStatsShow 2 Fabric OS Command Reference Manual 537 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 570
is persistent across reboots and power cycles. To undo a previous following operands: slotnumber1 For bladed systems only, specify the slot bladed systems. Use switchShow to display a list of valid ports. slotnumber2 For bladed systems its slot for bladed systems. Examples To swap area - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 571
disabled. The enabled state of the portswap feature is persistent across reboots and power cycles. Enabling or disabling the portswap feature does not effect previously performed portswap , portShow, portSwapEnable, portSwapShow, switchShow Fabric OS Command Reference Manual 539 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 572
command. The enabled state of the portswap feature is persistent across reboots and power cycles. Enabling or disabling the portswap feature does not effect previously performed portswap portShow, portSwapDisable, portSwapShow, switchShow 540 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 573
PortSwap is enabled Slot Slotport Swport Area 2 2 18 19 2 3 19 18 See Also portSwap, portDisable, portEnable, portShow, portSwap, portSwapDisable, portSwapEnable, switchShow Fabric OS Command Reference Manual 541 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 574
size][-seed seed][-listtype porttype] Description Use this command to isolate problems to a single replaceable element and isolate problems connected to a copper port. Only one frame is transmitted and received at a port as long as it can be supported and it is asked to do so. Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 575
command to view the types of pattern that are supported with portTest. dataTypeShow displays the pattern name, the pattern number is specified, is RANDOM (type=11) Specify the size of the pattern. Default size of the pattern is 1024 bytes. Valid range of values Reference Manual 543 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 576
StopTime: NONE Timeout: 0 PortState: NO TEST PortTypeToTest: NO_TEST UserDelay: 0 CurrentIteration: 0 ConsecutiveFail: 0 ErrorCode: 0 See Also fportTest, loopPortTest, portLoopbackTest, portTest, spinFab, stopPortTest 544 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 577
) Offline PORT: 180 (180) Offline [OUTPUT TRUNCATED] Enforcement: HARD WWN Enforcement: HARD WWN defaultHard: 0 IFID: defaultHard: 0 IFID: See Also cfgShow, switchShow Fabric OS Command Reference Manual 545 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 578
you to indicate the new order. Whenever a power supply goes out of service or a field-replaceable unit (FRU) is inserted, the system available power is compared to the system required power to determine if there is enough power to operate. If there is less power available than the demand, the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 579
POL Power Off Order 10 1 1st 9 2 2nd 8 3 3rd 7 4 4th 4 10 5th 3 9 6th 2 8 7th 1 7 8th Proceed to change the POL order? (yes, y, no, n): [no] y See Also chassisShow, powerOffListShow, psShow, slotPowerOff, slotPowerOn, slotShow Fabric OS Command Reference Manual 547 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 580
chassis, so that suddenly only one power supply is available to power a fully loaded system. However, if the system is running on two power supplies (this is not recommended) and one goes into predicted fail state (in which the power supply is still supplying power), the power off list processes as - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 581
-1001AB-1E 23000000601 S1 Power Supply #2 is faulty DELTA DPS-1001AB-1E 23000000601 S1 Power Supply #3 is OK DELTA DPS-1001AB-1E 23000000601 S1 Power Supply #4 is absent IXD0111000088 IXD0111000162 IXD0111000120 See Also chassisShow, fanShow Fabric OS Command Reference Manual 549 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 582
it off 1: to turn it on switch:admin> quietmode 0 Committing configuration...done Quiet Mode is now OFF See Also None 550 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 583
... To reboot the CP to failover to the Standby CP: switch:admin> reboot -f Warning: This command is being run on a control processor (CP) based system and will cause the active CP to reboot. Are you sure you want to reboot the active CP [y/n]? See Also fastboot, switchReboot, hafailover Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 584
Database entry Print neighbor's summary information Print paths to domain(s) Print port's unicast routing info See Also bcastShow, interfaceShow, uRouteShow 552 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 585
Kb. This command is intended strictly for debugging purposes by technical support staff. The information displayed might not be supported between releases and is subject to change arbitrarily. Operands none Examples To display the size of the active security database: switch:admin> secactivesize - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 586
secret is being set up. 2. Peer secret: The secret of the peer that authenticates to peer. (continued on next page) 554 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 587
fabric. Do want to remove secret key database? (yes, y, no, n): [no] y Deleting secret key database... Done. switch:admin> See Also none Fabric OS Command Reference Manual 555 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 588
secCertUtil Manages third-party PKI-based certificates in the switch. Synopsis specific certificate. • Configure SSL certificate file name. • Enable secure protocols. The following is the usage statement for the utility: seccertutil delcsr Delete OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 589
: 1. Delete all existing CSRs. 2. Delete all existing certificates. 3. Reset the certificate filename to none. 4. Disable secure protocols. Continue (yes, y, no, n): [no] y Select key size [1024 or 2048]: Generating new rsa public/private key pair Done. To generate a CSR: switch:admin> seccertutil - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 590
with configure and enable option: switch:admin> seccertutil import -config swcert -enable https Select protocol [ftp or scp]: ftp Enter IP address: ip address Enter remote directory: dir name where show certificate file name See Also none 558 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 591
Description Use this command to display the size of the defined security database. The maximum size is 256 KB. This command is intended strictly for debugging purposes by technical support staff. The information displayed might not be supported between releases and is subject to change - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 592
from a sectelnet or SSH session. When this command is issued on multiple switches in the fabric, one or more of these switches can display a status of busy. Operands none Examples To display security- and the IPv4 address information. 560 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 593
Primary 10:00:00:05:1e:34:14:db 1 Ready 10.202.90.106 "mps_daz_2" 1080::8:800:200C:417A secPolicyDump, secPolicyShow Fabric OS Command Reference Manual 561 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 594
FCS switch will be aborted. ARE YOU SURE (yes, y, no, n): [no] y WARNING!!! The FCS policy of Active and Defined Policy sets have been changed. Review them before you issue secPolicyActivate again. See Also secFabricShow, secModeDisable, secModeEnable, secModeShow 562 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 595
sizes of the security database This command is intended strictly for debugging purposes by technical support staff only. The information displayed might not be supported ---flag 1, saveflag 1 transId 0 Queue Size 0 final Rca 0 reliablemsg 0 reliablePhase size when calling zone: not used - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 596
DataSize 59 bytes Active Sum 8223 Security Defined DataSize 59 bytes Define Sum 8223 Zone Size (include enabled configuration) 4 bytes Zone sum fffb sec_db: free primaryDLPhase 0 ----wwnDL CACHE --------- See Also secActiveSize, secDefineSize 564 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 597
Displays existence of pki objects Displays size of the active (security) key details Creates/Manages/Displays third party PKI Displays size of the defined (security) database Displays security set and sends to all switches Shows members of one or more policies Displays all members of existing - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 598
current admin account password: Warning!!! About to disable security. ARE YOU SURE (yes, y, no, n): [no] y See Also secFabricShow, secModeEnable, secModeShow 566 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 599
admin password is used for non-FCS admin as well. If the fabric is not in secure mode and one or more specified FCS switches is present in the fabric, the command must be issued on the first active , WWN, or switch name format, as follows: Fabric OS Command Reference Manual 567 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 600
the primary FCS switch. This option should not be used when the fabrix is connect to a FC Router. If no operand is specified, the session becomes interactive and the user is prompted to enter FCS switch name: primaryfcs:admin> secmodeenable 568 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 601
based security features of the software installed on this equipment is subject to the End User License Agreement provided with the equipment and the Certification Practices Statement, which you may review accounts may be required for proper support of the switch. Ensure the Manual 569 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 602
the equipment and the Certification Practices Statement, which you may review at http://www.switchkeyactivation.com/cps. By using these security secmodeenable --currentpwd --fcs "*" Your use of the certificate-based security features of the software installed on this equipment is Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 603
more WWNs use the secPolicyAdd command. Ensure that all users (using Fabric OS CLI or Web Tools) are logged off the fabric before enabling secure mode. All users whose account passwords are changed , secModeDisable, secModeShow, secPolicyShow Fabric OS Command Reference Manual 571 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 604
:00:00:5a 21 switch47. 2 No 12:00:00:60:60:03:23:5b 5 switch12. See Also secFabricShow, secModeDisable, secModeEnable 572 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 605
changed will be terminated. Password for non-FCS admin account has been changed successfully. See Also passwd, secModeDisable, secModeEnable, secModeShow, secTempPasswdSet Fabric OS Command Reference Manual 573 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 606
been aborted. primaryfcs:admin> secpolicyabort No new data to abort. See Also secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow 574 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 607
YOU SURE (yes, y, no, n): [no] y secpolicyactivate command was completed successfully. See Also fddCfg, secPolicyAbort, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual 575 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 608
domains to the FCS policy if the secure edge fabric is connected to an FC Router. Operands This command has the following operands: "name" Specify the name of an IPF_POLICY • FCS_POLICY The specified policy name must be capitalized. 576 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 609
only SCC, DCC, and FCS policies. Fabric-wide consistence is not supported for AUTH_POLICY, IPF_POLICY and FCS_POLICY. NOTE Back-up FCS switches typically (for example, 124.23.56.122). If 0 is specified in one of the octets, any number can be matched. WWN Member Policy Manual 577 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 610
:44:55:66:77:bb;3(1,3)" Member(s) have been added to DCC_POLICY_abc. distribute, fddCfg, secPolicyAbort, secPolicyActivate, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave 578 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 611
for this operand are: • DCC_POLICY_nnn • TELNET_POLICY • HTTP_POLICY • API_POLICY • RSNMP_POLICY • WSNMP_POLICY • SES_POLICY • MS_POLICY • SERIAL_POLICY • FRONTPANEL_POLICY • SCC_POLICY • OPTIONS_POLICY • AUTH_POLICY • IPF_POLICY • FCS_POLICY Fabric OS Command Reference Manual 579 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 612
member IDs in dot notation (for example, 124.23.56.122). If 0 is specified in one of the octets, any number can be matched. WWN Member Policy Types The following policy types require include the devices currently attached to those ports. 580 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 613
:admin> secpolicycreate "TELNET_POLICY", "192.168.5.0" TELNET_POLICY has been created. See Also fddCfg, distribute, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow Fabric OS Command Reference Manual 581 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 614
maintain secure mode. When secure mode is enabled or when FCS policy is enabled on the switch in base FOS, this command can be issued only from the Primary FCS switch. Operands This command has the following " About to delete policy MS_POLICY. 582 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 615
secPolicyDelete 2 See Also Are you sure (yes, y, no, n):[no] y MS_POLICY has been deleted. secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual 583 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 616
> secpolicydump DEFINED POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes 10:00:00:60:69:30:15:5c 1 primaryfcs 584 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 617
.13 192.155.52.11 ACTIVE POLICY SET TELNET_POLICY IpAddr 192.155.52.0 secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual 585 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 618
this command to move an FCS member from one position to another position in the FCS list. Only one FCS can be moved at a time. The issued in secure mode from the Primary FCS switch.It is supported in non-secure mode for FCS policy management. Operands This Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 619
, domain, or switch name. IP Address Member Policy Types The following policy types require members be specified by IP address: TELNET_POLICY Fabric OS Command Reference Manual 587 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 620
IDs in dot notation (for example, 124.23.56.122). If 0 is specified in one of the octets, it means any number can be matched. WWN Member Policy Types The secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, 588 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 621
secPolicySave, secStatsShow secPolicyRemove 2 Fabric OS Command Reference Manual 589 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 622
memory: switch:admin> secpolicysave secpolicysave command was completed successfully. See Also fddCfg, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secStatsShow 590 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 623
existing policy in the Active or Defined security policy set. This command displays the policy database one page at a time. Use secPolicyDump to display the policy database without page breaks. In secure displays only SCC and DSS policies. Fabric OS Command Reference Manual 591 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 624
.155.53.1 192.155.54.2 192.155.55.3 192.155.56.4 fddCfg, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave 592 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 625
security statistics to 0. Synopsis secstatsreset ["name"][,"list"] Description Use this command to reset one or all security statistics to 0. This command can be issued to any switch. for all DCC_POLICY violations are grouped together. Fabric OS Command Reference Manual 593 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 626
. See Also To reset DCC_POLICY statistics on domains 1 and 69: switch:admin> secstatsreset "DCC_POLICY", "1;69" Reset DCC_POLICY statistic. secFabricShow, secStatsShow 594 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 627
all security statistics. Synopsis secstatsshow ["name"[, "list"]] Description Use this command to display one or all security statistics. This command can be issued to any switch. If issued The specified policy name must be all capitalized. Fabric OS Command Reference Manual 595 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 628
> secstatsshow "TELNET_POLICY", "*" Fabric Statistics: Domain 1: Name Value TELNET_POLICY 0 Domain 69: Name Value TELNET_POLICY 0 Domain 70: Name Value TELNET_POLICY 0 secFabricShow, secStatsReset 596 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 629
-wide values. Root and factory accounts on each Non FCS switch have been disabled. See Also secModeDisable, secModeEnable, secModeShow, secNonFCSPasswd, secTempPasswdSet Fabric OS Command Reference Manual 597 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 630
password changed will be terminated. Password successfully set on domain 2 for root See Also passwd, secModeDisable, secModeEnable, secModeShow, secNonFCSPasswd, secTempPasswdReset 598 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 631
the current transaction. This command is used to recover from management application problems. This command aborts all current changes that have not been committed or , secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow Fabric OS Command Reference Manual 599 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 632
sure (yes, y, no, n):[no] y done. Security Policy Version Stamp has been set to 0. See Also secFabricShow, secModeDisable, secModeEnable, secModeShow, secTransAbort 600 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 633
) is Ok, speed is 2537 RPM sensor 9: (Fan ) is Ok, speed is 2556 RPM sensor 10: (Power Supply ) is Ok sensor 11: (Power Supply ) is Absent sensor 12: (Power Supply ) is Ok sensor 13: (Power Supply ) is Absent See Also fanShow, tempShow Fabric OS Command Reference Manual 601 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 634
debug level values can generate a large volume of messages, degrading the system response time. The set of supported modules and their current debug levels are displayed by the command dbgShow. level = 3, verbose level = 0 lSee Also dbgShow 602 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 635
this command on the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. This availability is offered to Esd Mode is 0 (Disabled). See Also spinSilk Fabric OS Command Reference Manual 603 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 636
enable the media mode: switch:admin> setgbicmode 1 GBIC mode is now 1 (Enabled). See Also itemList, miniCycle, setMediaMode, setSfpMode, spinJitter, spinSilk 604 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 637
display the media mode: switch:admin> setmediamode -show Media mode is now 0 (disabled). See Also itemList, miniCycle, setGbicMode, setSfpMode, spinJitter, spinSilk Fabric OS Command Reference Manual 605 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 638
Use this command to enable or disable modem dial-in to a CP on those systems that support modem dial-in. When modem dial-in is enabled, you can log in to to the wall outlet. During an incoming call, both modems ring and the one connected to the active CP answers the call first. If for any reason - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 639
Telco Line DB-25M to DB-9F Modem Cable (one per CP Card) Note: Modem power connections not shown ! 1 2 3 4 5 6 7 8 9 10 ! Modem Port on CP Card (one per CP Card; RS-232 port interface) POWER SUPPLY 4 ! 15 d 14 c 13 b 12 a 11 Fabric OS Command Reference Manual 607 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 640
display the media mode: switch:admin> setsfpmode 0 SFP mode is now 0 (disabled). See Also itemList, miniCycle, setGbicMode, setMediaMode, spinJitter, spinSilk 608 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 641
This might be useful to isolate internal switch problems from SFP problems since the internal paths are used much less -18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. Reference Manual 609 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 642
to value 3: switch:admin> setverbose NS 3 switch:admin> dbgshow NS Module NS, debug level = 0, verbose level = 3 See Also dbgShow, setDbg 610 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 643
display: module temperature, voltage, received optical power, transmitted optical power (longwave only), and laser diode drive Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if Manual 611 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 644
Code: 020429 Temperature: 50 Centigrade Current: 10634 mAmps Voltage: 3164.8 mVolts RX Power: 199.6 uWatts TX Power: 235.2 uWatts To display detailed information for GbE port 0 on a Brocade : 0 Serial No: A00107001 Date Code: 020313 612 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 645
sfpShow 2 To display detailed information for GbE port 0 on an FR4-18i router blade: CS48000:admin> sfpshow 10/ge0 Identifier: 3 SFP Connector: 7 LC Transceiver : 050c402000000000 100,200_MB/s M5,M6 sw Inter_dist Encoding: 1 8B10B Fabric OS Command Reference Manual 613 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 646
: 0 (units nm) Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 5 BR Min: 5 Serial No: 21P70530005BW Date Code: 01062301 (output truncated) switchShow 614 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 647
This setting saves in the configuration database; therefore, persistent across reboots and power cycles. On dual control processor (CP) systems, a reboot on the standby CP is required for this command to disabled See Also shellFlowControlEnable Fabric OS Command Reference Manual 615 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 648
This setting saves in the configuration database; therefore, persistent across reboots and power cycles. On dual control processor (CP) systems, a reboot on the standby CP is required for this command to See Also shellFlowControlDisable 616 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 649
. Description This command is not supported on this platform as of FOS 5.1 - use slotPowerOff. The execution of this command is subject to Admin Domain restrictions that may be in place. See Also slotShow, slotPowerOff, bladeDisable Fabric OS Command Reference Manual 617 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 650
slotPowerOn. Description This command is not supported on this platform as of FOS 5.1 - use slotPowerOn. The execution of this command is subject to Admin Domain restrictions that may be in place. See Also slotShow, slotPowerOn, bladeEnable 618 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 651
Specify the slot number of the blade to be powered down. This operand is required. Examples To power off blade unit 3: switch:admin> slotpoweroff 3 Slot 3 is being powered off See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow Fabric OS Command Reference Manual 619 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 652
the blade unit must be currently powered off. The slotShow command reports such slots as being in the state of INSERTED, NOT POWERED ON. The execution of this command blade to be powered on. This operand is required. Examples To power on blade unit 3: switch:admin> slotpoweron 3 Powering on slot 3. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 653
and display the current status of each slot in the system. The fields and their possible values are as follows powered on, and running the POST (power-on self-test). DIAG RUNNING POST2 The blade is present, powered on, and running the preboot power on self tests). Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 654
disabled using bladeDisable. DISABLED The blade is powered on but disabled. FAULTY The blade is To display the status of all slots in the system: switch:user> slotshow Slot Blade Type ID Status SW BLADE 17 INSERTED, NOT POWERED ON 10 UNKNOWN VACANT See Also bladeDisable, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 655
The test method is as follows: Set all ports present for one of the following modes: parallel, SERDES pads, or external cable count requested is reached. All ports are marked bad. This command is supported only on Brocade 200E, 4100, and 48000 platforms. The execution of Manual 623 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 656
sltest -ports 0/5-0/31 -speed 4 -lb_mode 1 passcnt 1 Running Port sltest .... passed. Diagnostic When it detects failures, the test might report one or more of the following error messages: DATA ERRSTAT INIT STATS TIMEOUT See Also cmemRetentionTest, itemList, portRegTest, spinSilk 624 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 657
group. It supports set, reset to default, and display operations. Issue this command with incomplete parameters and it displays the command usage. All values successfully changes by this command take effect immediately and are persistent across power cycles and reboots. For dual-domain systems, this - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 658
supported supported. protocol MD5/SHA or no authentication for each entry. Select the following combination of protocols and noPriv protocol. The factory protocol. You are prompted for password and re-confirmation of password, if any protocol is selected other than NoAuth/NoPriv. The length of protocol - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 659
to pass the ACL check as described in accessControl section. The trap recipient value should be associated with one of the six users of SNMPv3 and trap severity level. Note that the factory default value for SW traps. The default value is 'no'. Fabric OS Command Reference Manual 627 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 660
value is set as Field Support. Refer to the definition of sysDescr, sysLocation and sysContact in system group of MIB-II. When enabled, the authentication trap (authenticationFailure) is transmitted to a configured trap recipient in the event that the agent received a protocol message that is not - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 661
configuration parameters related to the system group. systemGroup parameters include : [0.0.0.0] 1080::8:800:200C:1234 Community (rw): [OrigEquipMfr] string size must be between 2 and 16 - please re-enter Community ( in dot notation: [0.0.0.0] Fabric OS Command Reference Manual 629 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 662
Network Management Protocol (SNMPv1)" RFC1213, "Management information Base for Network Management of TCP/IP-based internets: MIB-II" RFC2574, "User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)" 630 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 663
turn on the desired traps individually. See the Fabric OS MIB Reference Manual for more information. The execution of this command is subject to Admin Domain : switch:admin> snmpmibcapset The SNMP Mib/Trap Capability has been set to support FE-MIB SW-MIB FA-MIB FICON-MIB HA-MIB SW-TRAP swFCPortScn - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 664
] HA-TRAP (yes, y, no, n): [yes] fruStatusChanged (yes, y, no, n): [yes] cpStatusChanged (yes, y, no, n): [yes] fruHistoryTrap (yes, y, no, n): [no] agtCfgDefault, agtCfgSet, agtCfgShow 632 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 665
. The FE and SW MIBs always are accessible. snmpMibCapSet does not prompt the user to turn on or off these MIBs. Fabric OS Command Reference Manual 633 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 666
-TRAP: NO SW-EXTTRAP: NO HA-TRAP: YES fruStatusChanged: YES cpStatusChanged: YES fruHistoryTrap: NO See Also agtCfgDefault, agtCfgSet, agtCfgShow, snmpConfig 634 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 667
generated if a port stops or a low-level error occurs. Every one million frames, the circulating frames are captured to verify that they are . If multiple ISL links are present between two switches that support trunking, then it is likely that trunk groups are present and Manual 635 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 668
2 spinFab -setfail mode Instruct spinFab how to mark failed ports. If set to passed. Diagnostics When it detects failure(s), the test might report one or more of the following error messages: DATA ERR_STAT ERR_STATS information. 636 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 669
See Also camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, spinSilk, sramRetentionTest spinFab 2 Fabric OS Command Reference Manual 637 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 670
the procedures used in this test, refer to spinSilk. The command is supported only on Brocade 200E, 3250, 3850, 3900,4100, 24000, and 48000 the test. This parameter is used for Bloom and Condor ASIC-based products only, for which it controls the speed at which Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 671
(output truncated) Diagnostics When it detects failure(s), the test might report one or more of the following error messages: DATA EPI1_STATUS_ERR ERR_STAT ERR_STATS ERR_STATS_2LONG ERR_STAT_2LONG ERR_STAT_BADEOF ERR_STAT_BADOS Fabric OS Command Reference Manual 639 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 672
the Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 640 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 673
of port M. Each port M sends one frame to its partner port N. The If self-loopback plugs are used, the system assigns a set of partner ports to optimize fails. The command is supported only on Brocade 200E one frame through port M. The frame used is one of the following: 2112 bytes of BYTE_LFSR 1000 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 674
is nonzero-ENC_in, CRC_err, TruncFrm, FrmTooLong, BadEOF, Enc_out, BadOrdSet, DiscC3-until one of the following is met: The number of million frames requested per port is met ) loopback 3 Silkscreen loopback 5 Internal (parallel) loopback 642 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 675
speed mode for the test. This parameter is used only for Bloom and Condor ASIC-based products, where it controls the speed at which each port is operated. For 1 Gbit -ports 1/0 - 1/2 Running Spin Silk One moment please ...Ports Segmented (0) switchName: Reference Manual 643 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 676
the Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinJitter, sramRetentionTest 644 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 677
the switch using the switchDisable command. The command is supported only on Brocade 200E, 3250, 3850, 3900,4100, omit in the test. Using this option, you can intentionally omit one or more patterns if needed. This command uses the following data patterns Reference Manual 645 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 678
Refer to the Fabric OS Message Reference for more information. See Also camTest, centralMemoryTest, cmemRetentionTest, cmiTest, dataTypeShow, itemList, portLoopbackTest, spinSilk 646 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 679
this command on the FR4-18i blade in a Brocade chassis; however, the command is not supported by the Brocade platform and does not effect any other feature operations. This availability is offered to 1/10-1/62 -use_bports 1 See Also itemList Fabric OS Command Reference Manual 647 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 680
statistics counter logic. It can run on every base port of the quadrant and send the frame gathering statistics that match the link. This command is supported only on Brocade 3250, 3850, 3900,and 24000 platforms When it detects failures, the subtest reports one or more of the following error messages - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 681
See Also camTest, itemList statsTest 2 Fabric OS Command Reference Manual 649 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 682
for further details. Examples To stop the portTest command: switch:admin> stopporttest See Also fportTest, loopPortTest, portLoopbackTest, portTest, portTestShow, spinFab 650 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 683
) is disabled. To enable the FFDC events: switch:admin> supportffdc --enable First Failure Data Capture (FFDC) is enabled. See Also none Fabric OS Command Reference Manual 651 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 684
supportftp -R supportftp -e Description Use this command to set, clear, or display support FTP parameters, or a time interval to check the FTP server. This : 1080::8:800:200C:417A User name: njoe Remote Dir: support FTP Auto check: Off 652 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 685
auto file transfer: switch:admin> supportftp -e support auto file transfer enabled. See Also To disable auto file transfer: switch:admin> supportftp -d support auto file transfer disabled. supportSave, supportShow, traceDump supportFtp 2 Fabric OS Command Reference Manual 653 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 686
other support information support information to a remote FTP location. On a dual CP system switch, it will also retrieve support file (as a .tar.gz on a dual-CP system, run supportFtp on |scp Specifies the FTP or SCP protocol. If you plan to use secure scp mode services. Because the supportSave - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 687
service support and other support information and and transfers the latest one. There will be : tmp Saving support information for switch support information for switch:routing1, module:TRACE_NEW... ..._files/routing1-S6-200508280151-new-tracedump.dmp: 12.00 MB 1.91 MB/s Saving support support - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 688
system: switch:admin> supportsave This command will collect RASLOG, TRACE, supportShow, core file, FFDC data and other support generate and transfer latest one. There will be two support information for switch:routing1, module:RASLOG... 656 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 689
support information for switch:routing1, module:TRACE_NEW... ..._files/routing1-S6-200508280151-new-tracedump.dmp: 12.00 MB 1.91 MB/s Saving support S6-200508280208-NS_evlog.ss: 2.72 kB 928.95 B/s Saving support information for switch:routing1, module:FSPF_Log... ...e_files/routing1-S6- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 690
is a diagnostic command and should only be run for diagnostic support. Refer to "supportShow Reference", for more information. The commands have in groups identified as follows: OS (ENABLED by default) mii-tool du ps rpm dmesg fstab mtab cat/proc/meminfo various proc Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 691
fabPortShow fspfShow nbrStateShow fcpLogShow zone stateshow portZoneShow cfgShow cfgSize rcssmshow rcsInfoShow rcsregistryshow zone mergeshow zone stateshow services (ENABLED by default) fdmiCacheShow fdmiShow nsShow nsAllShow nscamShow nscamShow -t ns portshow security (ENABLED by default) authUtil - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 692
bootenv sin df ifconfig route hostname portlog (ENABLED by default) portLogDump system (ENABLED by default) myId version firmwareShow upTime switchStatusShow switchShow haDump emhsmtraceshow systraceshow -d fwAlarmsFilterShow chassisShow timeout 660 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 693
-A FC-FC Routing (DISABLED by default) fcrProxyDevShow fcrProxyConfig fcrXlateConfig fcrPhyDevShow fcrRouteShow fcrFabricShow fcrResourceShow FCIP (DISABLED by default) portShow fciptunnel ge$k all Fabric OS Command Reference Manual 53-1000436-01 supportShow 2 661 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 694
be provided when specifying a range of ports on multi-bladed products. lines Specifies the number of lines of debugging: switch:admin> supportshow 1/1-3 supportshow groups enabled: system version: Kernel: 2.4.19 Fabric OS: v4.1.0 Made 662 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 695
service group commands security Disables the security group commands network Disables the network group commands portlog Disables the portlog group commands system Disables the system supportShow, supportShowCfgEnable, supportShowCfgShow Fabric OS Command Reference Manual 663 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 696
command. Synopsis supportshowcfgenable [os | exception | port | fabric | services | security | network | portlog | system | extend | filter | perfmon | ficon] Description Use this Also supportShow, supportShowCfgDisable, supportShowCfgShow 664 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 697
thesupportShow command: switch:admin> supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter disabled perfmon disabled ficon disabled See Also supportShow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 698
example) is suppressed and only the beaconing pattern is shown. However, if diagnostic frame-based tests (like portLoopbackTest and spinSilk) are executed, two patterns are interleaved. The diagnostic off: switch:admin> switchbeacon 0 switchShow 666 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 699
that may be in place. Operands none Examples To disable a switch persistently: switch:admin> switchcfgpersistentdisable See Also switchDisable, switchEnable, switchCfgPersistentEnable, switchShow Fabric OS Command Reference Manual 667 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 700
persistently enable the switch. All Fibre Channel ports which did not fail power-on self-test (POST) are enabled, and can come online if switch fabric: Domain 1 See Also switchDisable, switchEnable, switchCfgPersistentDisable, switchShow 668 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 701
configuration is saved in flash memory and persists across switch reboots or power cycles. If any port on the switch is not capable of speed of a port. This operand is required. Valid values are one of the following: 0 Auto sensing mode. The port automatically configures Manual 669 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 702
is required. Examples To enable trunking on a switch: switch:admin> switchcfgtrunk 0 Committing configuration...done. See Also portCfgShow, portCfgTrunkPort, portShow, switchShow 670 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 703
invoked while the switch is enabled. The switch does not need to be disabled before rebooting or powering off. As each port is disabled, the front panel LED changes to a slow flashing yellow , switchCfgPersistentEnable, switchEnable, switchShow Fabric OS Command Reference Manual 671 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 704
that may be in place. Operands none Examples To enable a switch: switch:admin> switchenable See Also switchCfgPersistentDisable, switchCfgPersistentEnable, switchDisable, switchShow 672 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 705
refer to FC-FLA for a description of RSCNs). The switch name also can be changed using Web Tools. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands dilbert See Also chassisShow, switchShow Fabric OS Command Reference Manual 673 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 706
running switchShutdown. This command is not supported on single-domain systems. The execution of this command is Powering off slot 1...Done. Powering off slot 4...Done. Checking all slots are powered Starting all switch daemons...Done. Powering on slot 1...Done. Powering on slot 4...Done. Checking - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 707
2-based platforms, private device targets are displayed in switchShow. For Condor or Goldeneye-based platforms Router The FC Router's state (on or off) FC Router BB Fabric ID The backbone fabric ID for FC routing. The switch summary is followed by one-line description for non-EX_Ports and one - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 708
Lock_Ref Testing Offline Online The 24-bit Address Identifier. Address column is only displayed for slot-based platforms. Media types include: -- no module present sw shortwave laser w longwave laser cu ports only). Port is up and running. 676 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 709
Protocol support by GbE port. ISCSI Ports support ISCSI. FCIP Ports support of the attached switch is the same as the router. F_Port Point-to-point port; displays WWN of ID ( EX_Ports only). Fabric ID oversubscribed One fabric has been assigned two different fabric Manual 677 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 710
0 zoning: ON (bot_cfg) switchBeacon: OFF blade4 Beacon: OFF blade8 Beacon: OFF FC Router: OFF FC Router BB Fabric ID: 1 Index Slot Port Address Media Speed State Proto [output truncated] (Persistent) Disabled (Persistent) F-Port 678 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 711
N2 Online F-Port 10:00:00:00:00:03:00:00 0x060705 with agmode enabled: See Also portCfgLongDistance, switchDisable, switchEnable, switchName Fabric OS Command Reference Manual 679 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 712
switchShutdown Not supported on this platform. Synopsis Description switchshutdown This command is not supported on this platform as of FOS 5.1. The execution of this command is subject to Admin Domain restrictions that may be in place. 680 Fabric OS Command Reference Manual 53-1000436 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 713
switchStart Not supported on this platform as of Fabric OS 5.1. switchStart 2 Fabric OS Command Reference Manual 681 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 714
For example, assuming that the switch contributor values are set to the default values, if there is one faulty port in a switch, then this contributor would set the overall switch status to MARGINAL. 2 1 Fans 2 1 WWN 0 1 CP 0 1 682 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 715
Flash contributing to MARGINAL status: (0..1) [1] MarginalPorts contributing to DOWN status: (0..64) [2] MarginalPorts contributing to MARGINAL status: (0..64) [1] (output truncated) switchStatusPolicyShow, switchStatusShow Fabric OS Command Reference Manual 683 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 716
:admin> switchstatuspolicyshow The current overall switch status policy parameters: Down Marginal PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 684 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 717
MissingSFPs 0 0 See Also switchStatusPolicySet, switchStatusShow switchStatusPolicyShow 2 Fabric OS Command Reference Manual 685 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 718
the overall switch status, and the status of the following contributors: Power supplies Temperatures Fans WWN servers (dual CP systems only) Standby CP (dual CP systems only with HA enabled) Blades (bladed systems only) Flash Marginal ports Faulty ports Missing SFPs Status values are HEALTHY - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 719
MARGINAL Duration: 80:12 Report time: 09/11/2006 05:39:28 PM Power supplies monitor Temperatures monitor Fans monitor Flash monitor Marginal ports monitor Faulty ports monitor Missing healthy switchStatusPolicySet, switchStatusPolicyShow Fabric OS Command Reference Manual 687 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 720
Examples To view the uptime for the switch: switch:user> switchuptime 9:50pm up for 20 mins See Also switchReboot, switchShutdown 688 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 721
a process available on most UNIX systems that reads and forwards system messages to the appropriate log files or users, depending on the system configuration. The specified facility is See Also syslogdIpAdd, syslogdIpRemove, syslogdIpShow Fabric OS Command Reference Manual 689 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 722
system configuration. When one or more IP addresses are configured, the switch forwards all error log entries to the syslogd on the specified server(s). Up to six servers are supported 800:200C:417A to the list of machines to which system messages are sent: switch:admin> syslogdipadd 1080::8:800:200C - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 723
syslogd. This operand is required. Examples To remove the address 1080::8:800:200C:417A from the list of machines to which system messages are sent: switch:admin> syslogdipremove 1080::8:800:200C:417A See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpShow Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 724
syslog daemon IP addresses: switch:admin> syslogdipshow syslog.IP.address.1 1080::8:800:200C:417A See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpRemove 692 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 725
the active CP, standby CP, and any AP blades. After doing this, you need to manually power off the system. If you want to reboot the system, manually turn the power switch on. This command is not supported on the standby CP. The execution of this command is subject to Admin Domain restrictions that - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 726
busy umount: /tmp: device is busy The system is halted flushing ide devices: hda Power down. ppc440gx System Halted For the FR4-18i AP blade, to perform a system shutdown from the standby CP: switch:admin> sysshutdown Shut down the whole system is not support from the standby CP For shut down the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 727
on a single FRU in the system. The valid options for type are BLADE, PS, FAN, and WWN; however, only BLADE is supported at this time. Since only one FRU type is supported, this parameter is optional, but Message Reference for more information. Fabric OS Command Reference Manual 695 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 728
2 systemVerification Examples To initiate a system verification test on all switches in the fabric: switch:admin> systemverification -short systemverification: Setting parameters for short , burninStatus, diagSetBurnin, diagSetCycle 696 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 729
applicable), the sensor state, and the temperature. The temperature readings are given in both Centigrade and Fahrenheit. Refer to the hardware reference manual for your switch to determine the normal temperature range. The execution of this command is subject to Admin Domain restrictions that may - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 730
IDLE Timeout Changed to 10 minutes The modified IDLE Timeout will be in effect after NEXT login See Also none 698 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 731
A bandwidth that is less than 0.512 Gbit/sec is adjusted to the nearest power of 2 value, while a bandwidth that is ranged from 0.512 Gbit/sec (included path is discovered automatically by the FSPF path selection protocol. The execution of this command is subject to Admin Manual 699 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 732
Gbps 0 % D Hops: Out Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: 1 58 None 2.000 Gbps 0 % D See Also fcrXlateConfig, portRouteShow, uRouteShow 700 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 733
the trace dump time. If non-blade system has an embedded BP, two trace dumps will be generated, one with .dmp for the main switch and one with .tar.gz for the embedded BP dump removed supportFtp, supportSave, supportShow, traceFtp, traceTrig Fabric OS Command Reference Manual 701 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 734
:admin> trackchangeshelp trackChangesSet Configure alert for login/logout/config update trackChangesShow Displays status of track changes See Also trackChangesSet, trackChangesShow 702 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 735
configuration...done. switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP-TRAP: YES See Also agtCfgSet, agtCfgShow, trackChangesHelp, trackChangesShow Fabric OS Command Reference Manual 703 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 736
track-changes feature: switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP-TRAP: YES See Also trackChangesHelp, trackChangesSet 704 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 737
one of the following messages, based on the trunking properties of the two specified ports: Switch does not support trunking Trunking license required Trunking not supported sure difference is less than 400 m The execution of this command 44 Switch does not support trunking switch:admin> trunkdebug - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 738
:69:51:42:dd deskew 15 MASTER To display trunking information for a switch that is part of an FC Router backbone fabric interlinking several edge fabrics (see the EX_Port with WWN "10:00:00:05:1e:35:b3:03" 00:00:05:1e:35:b3:03 4 deskew 16 MASTER 706 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 739
Slot 7 Port E-Port (Trunk port, master is Slot 7 Port E-Port 10:00:00:05:1e:37:12:13 "SW4900_43" portCfgTrunkPort, switchCfgTrunk Fabric OS Command Reference Manual 707 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 740
lists of NTP server addresses instead of just one address. The NTP server addresses can be connect to the NTP server and broadcast time service updates. All switches in the fabric maintain the it is necessary that an NTP server that supports a full NTP client be used. The ipaddr Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 741
See Also Updating Clock Server configuration...done. switch:admin> tsclockserver 123.123.123.123 date tsClockServer 2 Fabric OS Command Reference Manual 709 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 742
zone: that is, GMT. If all switches in a fabric are in one time zone, it is possible to leave the time zone setup at the time zone setup does not affect the switch operation in any way. System services started during the switch boot reflect time-zone change only at the Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 743
0 Time Zone Minute Offset: 0 switch:admin> tstimezone -3, -30 Updating Time Zone configuration...done. System Time Zone change will take effect at next reboot. switch:admin> tstimezone Time Zone Hour Offset: quit ?45 (continued on next page) Fabric OS Command Reference Manual 711 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 744
2 tsTimeZone Please select one of the following time zone regions. 1) Eastern Time 2) Eastern Time - Michigan . Is the above information OK? 1) Yes 2) No Enter number or control-D to quit ?1 System Time Zone change will take effect at next reboot To revert back to the old format: switch admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 745
perform the SRAM write and read operations at a much faster rate. It is also able to test one SRAM in each quadrant of every chip, in parallel. The test flow for each SRAM is as , cmemRetentionTest, cmiTest, portRegTest, sramRetentionTest Fabric OS Command Reference Manual 713 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 746
it is compared with the transmitted data. Only one frame is transmitted and received at any one time. External cable is not required to run requested, the first seven frames use unique data type. This command is supported only on Brocade 200E,3250, 3850, 3900,4100, 24000, and Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 747
-spd_mode mode Specify the speed for the test. This parameter is used only for Bloom and Condor ASIC-based products, where For 1 Gbit/sec-only products, this option is ignored. The exact operation of modes ports. To run the txdPath test: Fabric OS Command Reference Manual 715 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 748
47 sec (0:0:47:645). Diagnostics See Also When it detects failure(s), the test can report one or more of the following error messages: DATA ERRSTAT INIT PORTDIED STATS TIMEOUT XMIT Refer to the , portRegTest, spinSilk, sramRetentionTest 716 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 749
one line display of the following information. The current time, how long the system has been running, how many users are currently logged on, and the system load averages for the past 1, 5, and 15 minutes. For up and powered display the length of time the system has been operational: switch:admin> - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 750
non-minimum-cost paths are not enforced. Static route configuration is not supported on Brocade directors set to chassis configuration option 5 by chassisConfig. The 500 1 S 2,5 See Also configShow, interfaceShow, uRouteRemove, uRouteShow 718 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 751
for all traffic coming in from port 1 and addressed to domain 2: switch:admin> urouteremove 1 2 done. See Also configShow, dlsShow, uRouteConfig, uRouteShow Fabric OS Command Reference Manual 719 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 752
to Fabric OS Administrator's Guide for more information regarding the Fabric OS Administrator's Guide for more information by the FSPF path selection protocol. A static route is assigned : slotnumber For bladed systems only, specify the to its slot for bladed systems. Use switchShow to display a - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 753
Port Metric Hops Flags Next (Dom, Port) 0 1 11 1000 1 D 1,0 11 2 0 1500 2 D 4,0 4 0 500 1 D 4,0 16 1 27 1000 1 D 1,1 27 2 16 1500 2 D 4,16 4 Also portRouteShow, topologyShow, uRouteConfig, uRouteRemove Fabric OS Command Reference Manual 721 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 754
An account can access multiple Admin Domains, but only one Admin Domain at a time. New accounts created take use, such as monitoring system activity Operator A subset of entire Fabric. As a result, all switches supporting customer-defined accounts will have the same account Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 755
to username's Admin Domain list. If home Admin Domain is specified with the -h option, it must be one of the ADs in AD_ID_list. If a home Admin Domain is not specified and username did not previously have runs the userConfig --delete command. Fabric OS Command Reference Manual 723 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 756
(s) from username's Admin Domain list. If a home Admin Domain is specified, it must be one of the ADs in the Admin Domain permissions remaining after the ADs specified by the --deletead option -d "Joe Smith" Setting initial password for joe 724 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 757
128 from bob's AD member list. New home AD is set to 0: switch:admin> userConfig --deletead bob -a 128 -h 0 See Also none Fabric OS Command Reference Manual 725 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 758
security; otherwise, the switch is not allowed in the secure fabric. This command is not supported on all platforms. The execution of this command is subject to Admin Domain restrictions that may userrename USERID admin See Also secModeEnable 726 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 759
: Kernel Displays the version of switch kernel operating system Fabric OS Displays the version of switch Fabric OS dates are the same, because the switch starts running flash firmware at power-on. However, in the time period between firmwareDownload and the next reboot Manual 727 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 760
each consisting of one or two hexadecimal digits between to reboot the system (or switch on dual-domain systems), because the any firmwareDownload or (for bladed systems) CP failover occurs; otherwise, Rebooting switch 0 ... [system reboots] switch:root> wwn 10:00:ff:ff: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 761
same name). If the destination zone object is not already present in the Admin Domain, one is created (with type as source_zone_object). --expunge "zone_object" Removes all references to the specified zones in the zone database are validated. Fabric OS Command Reference Manual 729 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 762
buffer. 1 Uses the zone database stored in the persistent storage. 2 Uses the currently enforced zone database. This is the zone The reason for not being in the current enforcement table could be one of the following: The device is not online. The device is online but Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 763
the zone database in the current transaction buffer: switch:admin> zone --validate -m 0 To validate all zones in the zone database in the persistent storage: switch:admin> zone --validate -m 1 To validate the zone object zone_test in the zone database in the current transaction buffer: switch:admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 764
be added, in quotation marks, separated by semicolons. Quotation marks are required. Valid values can be one or more of the following: A switch domain and port area number pair; for example, "2, zoneCreate, zoneDelete, zoneRemove, zoneShow 732 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 765
name. A zone alias is created with the aliCreate command. The alias must resolve to a list of one or more of the following: • A switch domain and port area number pair. View the area numbers for is usually meant for servers and not for storage Fabric OS Command Reference Manual 733 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 766
in zone, in quotation marks, separated by semicolons. Quotation marks are required. Can be one or more of the following: A switch domain and port area number pair: for example, 1,2; array2" See Also zoneAdd, zoneDelete, zoneRemove, zoneShow 734 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 767
marks. This operand is required. Examples To delete the zone "Blue_zone": switch:admin> zonedelete "Blue_zone" See Also zoneAdd, zoneCreate, zoneRemove, zoneShow Fabric OS Command Reference Manual 735 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 768
Print Fabric Assist Zone information cfgClear cfgDisable cfgEnable cfgSize cfgTransAbort Clear all zone configurations Disable a zone configuration Enable a zone configuration Print size details of zone database Abort zone configuration transaction See Also none 736 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 769
"*" cfg: UK_cfg Red_zone; White_zone; Blue_zone cfg: USA_cfg Red_zone; White_zone; Blue_zone See Also cfgAdd, cfgClear, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, zoneObjectRename Fabric OS Command Reference Manual 737 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 770
; 21:00:00:20:37:0c:71:df See Also cfgAdd, cfgClear, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, zoneObjectCopy, zoneObjectRename 738 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 771
"USA_cfg", "UK_cfg" switch:admin> cfgshow "*" cfg: UK_cfg Red_zone; White_zone; Blue_zone See Also cfgAdd, cfgClear, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, zoneObjectCopy Fabric OS Command Reference Manual 739 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 772
zone, separated by semicolons. Quotation marks are required. This operand is required. A member can be one or more of the following: A switch domain and port area number pair: for example, enter Also zoneAdd, zoneCreate, zoneDelete, zoneShow 740 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 773
display all zones beginning with the letters "A" through "C": switch:admin> zoneshow "[A-C]*" zone: Blue_zone 1,1; array1; 1,2; array2 See Also zoneAdd, zoneCreate, zoneDelete, zoneRemove Fabric OS Command Reference Manual 741 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 774
2 zoneShow 742 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 775
Watch, Trunking, or Performance Monitoring, refer to the Fabric OS Administrator's Guide. Advanced Zoning Commands The following commands are available with the purchase of member from a zone. Displays zone information. Copies a zone object. Fabric OS Command Reference Manual 743 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 776
Displays zone configuration information. Displays zone and Admin Domain database size details. Aborts the current zoning transaction. Displays information about on Fabric OS v2.6.x and v3.x systems in the fabric; it is not supported on Fabric OS v4.x or v5.x. 744 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 777
. TABLE 3 Extended Fabrics Commands Command Description portCfgLongDistance Configures a port to support long-distance links. Fabric Watch Commands The following commands are available with switch status. Displays temperature readings. Fabric OS Command Reference Manual 745 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 778
information about trunking refer to the Fabric OS Administrator's Guide. TABLE 5 Brocade Trunking Commands Command Description portCfgTrunkPort switchCfgTrunk port. Clears statistics counters of a filter-based monitor. Deletes an end-to-end monitor on port. 746 Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 779
to the Secure Fabric OS Administrator's Guide. TABLE 7 Brocade Secure Fabric shared secret key information. Manages third-party PKI-based certificates in the switch. Displays the size of the defined security database. Displays security related Fabric OS Command Reference Manual 747 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 780
. Resets a password on a remote switch. Sets a temporary password on a remote switch. Aborts current security transaction. Resets the version stamp to 0. 748 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 781
from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Fabric OS Command Reference Manual 749 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 782
a single non-FCS switch which is segmented from a fabric. Community strings can be changed on the primary FCS switch only 750 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 783
from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Fabric OS Command Reference Manual 751 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 784
4 Commands Exclusive to the Primary FCS 752 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 785
Supported on the Standby CP The following commands are supported when logged into the standby CP. TABLE 1 Commands Supported on the Standby CP Command Description date Displays or sets the system Displays memory usage in the system. Fabric OS Command Reference Manual 753 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 786
on the Standby CP TABLE 1 Commands Supported on the Standby CP (Continued) Command Description myId Displays Enables or disables modem dial-in to a control processor (CP). supportSave Saves support information for RASLOG, TRACE, and supportShow. switchName Displays this switch's name. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 787
" on page 758 supportShow Control Commands The supportShow command is used to display support information by executing groups of preselected Fabric OS and Linux commands. The information group of commands from displaying under supportShow. Fabric OS Command Reference Manual 755 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 788
bloomsemshow semashow 1 fabricShow islShow trunkShow topologyShow fashow qlshow cfgShow fabStatsShow fablogdump Fabric OS v4.x/v5.x mii-tool -vv /usr/bin/du -xh / | /bin/sort: /bin/ps -elfh /bin cfgShow rcssmshow rcsinfoshow rcsregistryshow 756 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 789
Command Groups (Continued) Command Group Fabric OS v3.2.0 services nsShow nsAllShow nscamShow security network portlog secModeShow secPolicyDump secStatsShow secFabricShow /bin/df /sbin/ifconfig /sbin/route /bin/hostname portLogDump Fabric OS Command Reference Manual 757 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 790
Groups (Continued) Command Group Fabric OS v3.2.0 system version upTime switchShow tempShow psShow licenseShow diagShow portFlagsShow -n port# NOTE Many of the commands executed by supportShow are intended for support use only. These commands are not intended for end-users. Proc Entry - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 791
fc 248 fc-switch 249 fabsys 250 fss_kt 251 fss_data 252 fss_mgmt 253 portlog 254 platform Block devices: 1 ramdisk 3 ide0 7 loop Fabric OS Command Reference Manual 759 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 792
Active: 23464 kB Inactive: 49472 kB HighTotal: 0 kB HighFree: 0 kB LowTotal: 126700 kB LowFree: 31896 kB SwapTotal: 0 kB SwapFree: 0 kB 760 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 793
xfs rw,noatime 0 0 /diag /diag dfs rw 0 0 /proc/mtd dev: size erasesize name mtd0: 00010000 00010000 "boot environment" mtd1: 00070000 00010000 "boot prom" mtd2 0, device 6, function 0: Non-VGA unclassified device: Brocade Communications Systems, Inc. Bloom switch (rev 0). IRQ 26. -- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 794
/console 5 1 system:console /dev/tty /dev/tty 5 0 system:/dev/tty /proc/uptime /proc/uptime 158791.21 155710.77 /proc/version /proc/version Linux version 2.4.19 (swrel@sierra) (gcc version 2.95.3 20010112 (prerelease)) #1 Wed Mar 26 00:04:35 PST 2003 762 Fabric OS Command Reference Manual 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 795
Active/Standby availability: on chassis-based systems, check that the command is : checks such as whether the command is supported on the platform for which it is targeted OM OM N O N O OM O OM O OM O O O O O O O O O O Fabric OS Command Reference Manual 763 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 796
O O OM OM O O OM O O OM OM O O OM O O OM OM O O OM OM OM N OM O O OM OM OM N OM O N OM OM/N N N OM OM N N O N N N N N N N N N O O O O O O O O O O O O O N N 764 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 797
O N O OM OM OM N OM O N O OM OM OM N OM O N O OM OM OM N OM O N N OM N N N OM N OM O OM O O N OM O N O OM O O N OM O N O OM O O N OM O N Fabric OS Command Reference Manual 765 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 798
O O N OM O OM O OM O OM O OM O OM O OM O OM O OM O OM O OM OM N O N OM N O N O N O N OM N O N O N O N O N O N O N O N O O OM O O O O O O O O O O O O N O OM O N O N O N 766 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 799
N OM O N firmwareCommit O OM OM OM O OM O O firmwareDownload O OM OM OM O OM O O firmwareDownloadStatus O OM OM OM O OM O O firmwareRestore O OM OM OM O OM O O Fabric OS Command Reference Manual 767 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 800
OM N OM N OM N OM OM OM O O O OM O N O N N N O N O N O N O N O N O N O N O OM O N O N O N O N O N O N O N OM OM O O O O O O O O O O O O O O O O OM OM O N O N O N OM OM 768 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 801
OM OM O OM N O N OM O N O N O N O OM O N O N O N O OM O OM O OM O N O N O OM O N O N O N O N O N O N OM OM O O O OM O O OM N O O O O O N OM OM OM OM O N O O O N O N O N Fabric OS Command Reference Manual 769 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 802
N OM N OM N OM N OM N OM N OM O N O N O N O N O N O N O N O N O N O N O N OM OM O N O N O N O N O N O N O N O N O O N OM OM OM N OM O N O N O N O N O N O N O N O N O N 770 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 803
OM N OM OM N portCfgNPIVPort O OM OM OM N OM OM N portCfgPersistentDisable O OM OM OM N OM OM N portCfgShow O OM OM OM N OM OM N Fabric OS Command Reference Manual 771 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 804
OM OM N OM O N O OM OM OM O OM O N O OM OM OM O OM OM N O OM OM OM N OM O N O OM OM OM N OM O N 772 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 805
N O N O N O N OM OM O O O OM O N O N O N O OM N OM O OM O OM O OM O OM O OM OM OM O OM O OM O OM O OM O OM O OM O OM O OM O OM Fabric OS Command Reference Manual 773 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 806
O N spinSilk O OM OM OM N OM O N sramRetentionTest O OM OM OM N OM O N statsClear O OM OM OM N OM O N statsTest O OM OM OM N OM O N 774 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 807
O O N OM O N traceDump O OM OM OM O OM O OM traceFtp O OM OM OM O OM O OM trackChangesHelp N N N N N N N OM trackChangesSet O OM OM OM O OM O OM Fabric OS Command Reference Manual 775 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 808
OM OM OM OM OM OM OM OM OM O OM OM N OM N O OM O OM O N O N O N O N O N O N N OM OM OM N OM O O O OM O O O O O O O O O OM O O O O O O O O O O 776 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 809
A AAA services, 3 supportShow, 662 and switchBeacon, 666 BIST test, 194, 645 bladeDisable, 50 Bloom, 533 Bloom-based platform, 109, 358, 411, 469, 512, 609, 638, 643, 675, 715 Brocade burn-in and system verification, 695 burninErrClear, 53 burninErrShow, 54 burninLevel, 55 burninStatus, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 810
interface, 1 commands supported on the active CP, 753 commands supported on the standby CP, 753 committed traffic rate, 452 Condor-based platform, 109, dynamic load sharing DMA test, 194 domain name service, 142 dual CP system active CP and supportFTP, 654 dual-domain systems, 23, 26, 80, 339, 625, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 811
TRAP, 627, 630, 631, 632, 633, 634 faZoneCreate zoning, 175 FC Router, 194, 196, 199, 204, 205, 206, 208, 210, 211, 221, 222 Fibre Channel Association, xxv Fibre Channel Extended Link Service, 185, 245, 506, 542 Fibre Channel Protocol, 191, 192 FICON, 111, 223, 224, 225, Manual 53-1000436-01 Index 3 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 812
interfaceShow, 295 Inter-Switch Link, 425 interswitch link, 37, 48, 102, 155, 251, 252, 295, 331, 344, 375, 399, 400, 405, 422, 423, 424, 425, 426, 428, 429, 461, 462, 463, 464, 466, 470, 474, 477, 635, , 420, 421, 423, 426, 429, 431, 432, Index 4 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 813
704 minisPropShow ASIC properties, 361 modem, 373, 606, 607 MTU, 451, 452 Multiprotocol Router Model AP7420, 216 N Name Server, 102, 142, 146, 206, 210, 128, 129, 130, 134, 171, 603, 621, 668, 672 disabling, 120 power-on self-test, see POST primary FCS, 24, 27, 30, 32, 33 Manual 53-1000436-01 Index 5 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 814
, 108, 205, 357, 358, 512, 623, 638, 642, 715 serial port, 151, 336, 347, 373, 606, 615, 616 setMediaMode, 605 Index 6 Fabric OS Command Reference Manual 53-1000436-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 815
shutdown from the active CP, 694 SID used, 447, 448 single-domain systems, 78, 674 SNMP, 23, 24, 25, 26, 27, 28, active CP, 693 system services, 105, 710 system time zone, 710 systemGroupConfiguration 101, 102 Web Tools, 289, 425, 673 Z zone, 729 zone alias, 33 adding, 32 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual - Supporting F - Page 816
fcPing, 185 enabling zone configuration, 69 ISL R_RDY, 461 licensed commands, 743 zoning operation parameters, 104 zoning transaction aborting, 75 Index 8 Fabric OS Command Reference Manual 53-1000436-01
53-1000436-01
15 Jun 2007
Fabric OS
Command Reference Manual
Supporting Fabric OS v5.3.0