HP StorageWorks 4/64 Brocade Fabric OS Message Reference guide v6.2.0 (53-1001
HP StorageWorks 4/64 - SAN Switch Manual
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 4/64 manual content summary:
- HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 1
53-1001157-01 24 November 2008 Fabric OS Message Reference Supporting Fabric OS v6.2.0 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 2
feature, or service offered or to be offered by Brocade. Brocade reserves the brocade.com/support/oscd. Brocade Communications Systems, Incorporated Corporate Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Reference v4.2.0 Publication number Summary of changes 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 3
messages. Reference Manual June 2006 Fabric OS Message Reference 53-1000242-01 -Updated for Fabric OS v5.2.0: -changed doc title and number -Added the chapters. -Update throughout: rebranding, supported hardware, CLI changes. June 2007 Fabric OS Message Reference iii 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 4
Title Fabric OS Message Reference Fabric OS Message Reference Fabric OS Message Reference Fabric OS Message Reference Publication Summary of changes Date number 53-1000600-01 Updated for Fabric OS v6.0.0: -Added new chapters: C2, ESS, FICON -Added new messages to: AG, BL, BM, C2, FCIP, ISW, NS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 5
Contents About This Document In this chapter xlvii How this document is organized xlvii Supported hardware and software xlvii What's new in this document xlviii Document conventions xlix Additional information l Getting technical help li Document feedback lii Chapter 1 Introduction To - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 6
Responding to a System Message 11 Looking Up a System Message 11 Gathering Information About the Problem 12 Support 12 Panic Dump and Core Dump Files 12 Trace Dumps 13 supportSave Command 13 System Module Descriptions 13 Section I RASLog Messages Chapter 2 AG System Messages - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 7
Chapter 3 AG-1026 31 AG-1027 32 AG-1028 32 AG-1029 32 AUTH System Messages AUTH-1001 33 AUTH-1002 33 AUTH-1003 33 AUTH-1004 34 AUTH-1005 34 AUTH-1006 34 AUTH-1007 34 AUTH- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 8
Chapter 4 Chapter 5 AUTH-1037 43 AUTH-1038 43 AUTH-1039 43 AUTH-1040 44 AUTH-1041 44 AUTH-1042 44 AUTH-1043 45 AUTH-1044 45 BKSW System Messages BKSW-1003 47 BL System Messages BL-1000 49 BL-1001 49 BL-1002 49 BL-1003 50 BL-1004 50 BL-1006 50 BL-1007 51 BL-1008 51 BL-1009 51 BL- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 9
Chapter 6 Chapter 7 Chapter 8 BL-1025 57 BL-1026 57 BL-1027 58 BL-1028 58 BL-1029 58 BL-1030 59 BL-1031 59 BL-1032 59 BL-1033 59 BL-1034 60 BL-1035 60 BL-1036 60 BL-1037 61 BLL System Messages BLL-1000 63 BM System Messages BM-1001 65 BM-1002 65 BM-1003 65 BM-1004 66 BM-1005 66 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 10
C2-1005 72 Chapter 9 CDR System Messages CDR-1001 73 CDR-1002 73 CDR-1003 73 CDR-1004 74 Chapter 10 CER System Messages CER-1001 75 Chapter 11 CHASSIS System Messages CHASSIS-1002 77 CHASSIS-1003 77 CHASSIS-1004 77 CHASSIS-1005 78 Chapter 12 CNM System Messages CNM-1001 79 CNM- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 11
CNM-1021 84 CNM-1022 84 CNM-1023 84 CNM-1024 84 CNM-1025 85 CNM-1026 85 CNM-1027 85 CNM-1028 85 CNM-1029 86 CNM-1030 86 CNM-1031 86 CNM-1032 86 CNM-1033 87 CNM-1034 87 CNM-1035 87 CNM-1036 87 CNM-1037 88 CNM-1038 88 CNM-1039 88 CNM-1040 88 CNM-1041 89 CNM-1042 89 CNM-1043 89 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 12
CVLC-1015 98 CVLC-1016 99 CVLC-1017 99 CVLC-1018 99 CVLC-1019 99 CVLC-1020 100 CVLC-1021 100 CVLC-1022 100 Chapter 16 CVLMSystem Messages CVLM-1001 101 CVLM-1002 101 CVLM-1003 101 CVLM-1004 101 CVLM-1005 102 CVLM-1006 102 CVLM-1007 102 CVLM-1008 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 13
Fabric OS Message Reference 53-1001157-01 EM-1002 105 EM-1003 105 EM-1004 106 EM-1005 106 EM-1006 107 EM-1007 107 EM-1008 107 EM-1009 108 EM-1010 108 EM-1011 108 EM-1012 108 EM-1013 109 EM-1014 109 EM-1015 109 EM-1016 110 EM-1017 110 EM-1018 110 EM-1019 110 EM-1028 111 EM-1029 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 14
EM-1055 117 EM-1056 117 EM-1057 117 EM-1058 118 EM-1059 118 EM-1060 118 EM-1061 119 EM-1062 119 EM-1063 119 EM-1064 119 EM-1065 120 EM-1066 120 EM-1067 120 EM-1068 121 EM-1069 121 EM-1070 121 EM-2003 121 Chapter 18 ESS System Messages ESS-1001 123 ESS-1002 123 ESS-1003 123 ESS- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 15
FABR-1010 130 FABR-1011 130 FABR-1012 130 FABR-1013 131 FABR-1014 131 FABR-1015 131 FABR-1016 132 FABR-1017 132 FABR-1018 132 FABR-1019 132 FABR-1020 133 FABR-1021 133 FABR-1022 133 FABR-1023 134 FABR-1024 134 FABR-1029 134 FABR-1030 135 FABR-1031 135 FABR-1032 135 FABR-1034 136 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 16
FABS-1006 142 FABS-1007 142 FABS-1008 143 FABS-1009 143 FABS-1010 143 FABS-1011 143 FABS-1012 144 FABS-1013 144 FABS-1014 144 FABS-1015 145 Chapter 22 FBC System Messages FBC-1001 147 Chapter 23 FCIP System Messages FCIP-1000 149 FCIP-1001 149 FCIP-1002 149 FCIP-1003 149 FCIP-1004 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 17
Fabric OS Message Reference 53-1001157-01 FCR-1005 158 FCR-1006 158 FCR-1007 158 FCR-1008 158 FCR-1009 159 FCR-1010 159 FCR-1011 159 FCR-1012 160 FCR-1013 160 FCR-1015 160 FCR-1016 160 FCR-1018 161 FCR-1019 161 FCR-1020 161 FCR-1021 162 FCR-1022 162 FCR-1023 162 FCR-1024 163 FCR- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 18
FCR-1048 168 FCR-1049 168 FCR-1053 169 FCR-1054 169 FCR-1055 169 FCR-1056 170 FCR-1057 170 FCR-1058 170 FCR-1059 171 FCR-1060 171 FCR-1061 171 FCR-1062 171 FCR-1063 172 FCR-1064 172 FCR-1065 172 FCR-1066 173 FCR-1067 173 FCR-1068 173 FCR-1069 173 FCR-1070 174 FCR-1071 174 FCR- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 19
FCR-1088 179 FCR-1089 179 Chapter 28 FICON System Messages FICN-1003 181 FICN-1004 181 FICN-1005 182 FICN-1006 182 FICN-1007 182 FICN-1008 183 FICN-1009 183 FICN-1010 183 FICN-1011 183 FICN-1012 184 FICN-1013 184 FICN-1014 184 FICN-1015 185 FICN-1016 185 FICN-1017 185 FICN-1018 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 20
FICN-1036 190 FICN-1037 190 FICN-1038 191 FICN-1039 191 FICN-1040 191 FICN-1041 192 FICN-1042 192 FICN-1043 192 FICN-1044 192 FICN-1045 193 FICN-1046 193 FICN-1047 193 FICN-1048 194 FICN-1049 194 FICN-1050 194 FICN-1051 194 FICN-1052 195 FICN-1053 195 FICN-1054 195 FICN-1055 195 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 21
FICN-1073 200 FICN-1074 201 FICN-1075 201 FICN-1076 201 FICN-1077 202 FICN-1078 202 FICN-1079 202 FICN-1080 203 FICN-1081 203 FICN-1082 203 FICN-1083 204 FICN-1084 204 FICN-1085 204 FICN-1086 204 Chapter 29 FICU System Messages FICU-1001 205 FICU-1002 205 FICU-1003 205 FICU-1004 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 22
Chapter 32 FSPF System Messages FSPF-1001 213 FSPF-1002 213 FSPF-1003 213 FSPF-1005 214 FSPF-1006 214 Chapter 33 FSS System Messages FSS-1001 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 23
Fabric OS Message Reference 53-1001157-01 FW-1033 224 FW-1034 224 FW-1035 225 FW-1036 225 FW-1037 225 FW-1038 226 FW-1039 226 FW-1040 226 FW-1041 227 FW-1042 227 FW-1043 227 FW-1044 228 FW-1045 228 FW-1046 228 FW-1047 228 FW-1048 229 FW-1049 229 FW-1050 229 FW-1051 230 FW-1052 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 24
FW-1130 236 FW-1131 236 FW-1132 237 FW-1133 237 FW-1134 237 FW-1135 238 FW-1136 238 FW-1137 238 FW-1138 238 FW-1139 239 FW-1140 239 FW-1160 239 FW-1161 240 FW-1162 240 FW-1163 240 FW-1164 241 FW-1165 241 FW-1166 241 FW-1167 242 FW-1168 242 FW-1169 242 FW-1170 243 FW-1171 243 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 25
-1240 253 FW-1241 254 FW-1242 254 FW-1243 254 FW-1244 255 FW-1245 255 FW-1246 255 FW-1247 256 FW-1248 256 FW-1249 256 FW-1250 256 FW-1251 257 FW-1272 257 FW-1273 257 FW-1274 258 FW-1275 258 FW-1296 258 FW-1297 259 FW - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 26
FW-1299 259 FW-1300 260 FW-1301 260 FW-1302 260 FW-1303 261 FW-1304 261 FW-1305 261 FW-1306 262 FW-1307 262 FW-1308 262 FW-1309 263 FW-1310 263 FW-1311 263 FW-1312 264 FW-1313 264 FW-1314 264 FW-1315 265 FW-1316 265 FW-1317 265 FW-1318 266 FW-1319 266 FW-1320 266 FW-1321 267 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 27
Fabric OS Message Reference 53-1001157-01 FW-1336 272 FW-1337 272 FW-1338 272 FW-1339 273 FW-1340 273 FW-1341 273 FW-1342 274 FW-1343 274 FW-1344 274 FW-1345 275 FW-1346 275 FW-1347 275 FW-1348 276 FW-1349 276 FW-1350 276 FW-1351 277 FW-1352 277 FW-1353 278 FW-1354 278 FW-1355 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 28
FW-1373 284 FW-1374 285 FW-1375 285 FW-1376 285 FW-1377 286 FW-1378 286 FW-1379 286 FW-1400 287 FW-1401 287 FW-1402 287 FW-1403 288 FW-1424 288 FW-1425 288 FW-1426 288 FW-1427 289 FW-1428 289 FW-1429 289 FW-1430 290 FW-1431 290 FW-1432 290 FW-1433 290 FW-1434 291 FW-1435 291 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 29
Chapter 36 HAM System Messages HAM-1001 297 HAM-1002 297 HAM-1004 297 HAM-1005 298 HAM-1006 298 HAM-1007 299 HAM-1008 299 HAM-1009 299 Chapter 37 HAMK System Messages HAMK-1001 301 HAMK-1002 301 HAMK-1003 301 HAMK-1004 302 Chapter 38 HIL System Messages HIL-1101 303 HIL-1102 303 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 30
HIL-1306 309 HIL-1307 309 HIL-1308 309 HIL-1309 310 HIL-1310 310 HIL-1311 310 HIL-1401 310 HIL-1402 311 HIL-1403 311 HIL-1404 311 HIL-1501 311 HIL-1502 312 HIL-1503 312 HIL-1504 312 HIL-1505 313 HIL-1506 313 HIL-1507 313 HIL-1508 314 HIL-1509 314 HIL-1510 314 HIL-1601 315 HIL- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 31
333 IPS-1002 333 IPS-1003 333 IPS-1004 333 IPS-1005 334 IPS-1006 334 Chapter 47 ISCS System Messages ISCS-1000 335 Chapter 48 ISNS System Messages ISNS-1001 337 ISNS-1002 337 ISNS-1003 337 ISNS-1004 338 Fabric OS Message Reference xxxi 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 32
ISNS-1005 338 ISNS-1006 338 ISNS-1008 338 ISNS-1009 339 ISNS-1010 339 ISNS-1011 339 ISNS-1013 339 ISNS-1014 340 Chapter 49 KAC System Messages KAC-1002 341 KAC-1004 341 KAC-1006 341 KAC-1007 341 KAC-1008 342 Chapter 50 KSWD System Messages KSWD-1001 343 KSWD-1002 343 KSWD-1003 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 33
LOG-1001 349 LOG-1002 349 LOG-1003 350 Chapter 54 LSDB System Messages LSDB-1001 351 LSDB-1002 351 LSDB-1003 351 LSDB-1004 352 Chapter 55 MFIC System Messages MFIC-1001 353 MFIC-1002 353 MFIC-1003 353 Chapter 56 MPTH System Messages MPTH-1001 355 MPTH-1002 355 MPTH-1003 355 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 34
Chapter 59 NBFS System Messages NBFS-1001 365 NBFS-1002 365 NBFS-1003 366 Chapter 60 NS System Messages NS-1001 367 NS-1002 367 NS-1003 367 NS-1004 368 NS-1005 368 NS-1006 368 Chapter 61 PDM System Messages PDM-1001 369 PDM-1002 369 PDM-1003 369 PDM-1004 370 PDM-1005 370 PDM-1006 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 35
PDTR-1002 377 Chapter 63 PLAT System Messages PLAT-1000 379 PLAT-1001 379 PLAT-1002 379 PLAT-1003 380 Chapter 64 PMGR System Messages PMGR-1001 381 PMGR-1002 381 PMGR-1003 381 PMGR-1004 381 PMGR-1005 382 PMGR-1006 382 PMGR-1007 382 PMGR- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 36
Chapter 68 RAS System Messages RAS-1001 391 RAS-1002 391 RAS-1004 391 RAS-1005 391 RAS-1006 392 RAS-2001 392 RAS-2002 392 RAS-2003 392 RAS-3001 393 RAS-3002 393 RAS-3003 393 RAS-3004 393 Chapter 69 RCS System Messages RCS-1001 395 RCS-1002 395 RCS-1003 395 RCS-1004 396 RCS-1005 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 37
Chapter 72 RTWR System Messages RTWR-1001 403 RTWR-1002 403 RTWR-1003 404 Chapter 73 SAS System Messages SAS-1001 405 Chapter 74 SCN System Messages SCN-1001 407 Chapter 75 SEC System Messages SEC-1001 409 SEC-1002 409 SEC-1003 410 SEC-1005 410 SEC-1006 410 SEC-1007 411 SEC-1008 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 38
xxxviii SEC-1042 417 SEC-1043 417 SEC-1044 417 SEC-1045 417 SEC-1046 418 SEC-1049 418 SEC-1050 418 SEC-1051 419 SEC-1052 419 SEC-1053 419 SEC-1054 420 SEC-1055 420 SEC-1056 420 SEC-1057 421 SEC-1059 421 SEC-1062 421 SEC-1063 421 SEC-1064 422 SEC-1065 422 SEC-1069 422 SEC-1071 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 39
Fabric OS Message Reference 53-1001157-01 SEC-1088 427 SEC-1089 427 SEC-1090 428 SEC-1091 428 SEC-1092 428 SEC-1093 428 SEC-1094 429 SEC-1095 429 SEC-1096 429 SEC-1097 430 SEC-1098 430 SEC-1099 430 SEC-1100 430 SEC-1101 431 SEC-1102 431 SEC-1104 431 SEC-1105 432 SEC-1106 432 SEC- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 40
SEC-1136 437 SEC-1137 438 SEC-1138 438 SEC-1139 438 SEC-1142 439 SEC-1145 439 SEC-1146 439 SEC-1153 440 SEC-1154 440 SEC-1155 440 SEC-1156 441 SEC-1157 441 SEC-1158 441 SEC-1159 442 SEC-1160 442 SEC-1163 442 SEC-1164 442 SEC-1165 443 SEC-1166 443 SEC-1167 443 SEC-1168 443 SEC- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 41
Fabric OS Message Reference 53-1001157-01 SEC-1189 448 SEC-1190 449 SEC-1191 449 SEC-1192 449 SEC-1193 449 SEC-1194 450 SEC-1195 450 SEC-1196 450 SEC-1197 451 SEC-1198 451 SEC-1199 451 SEC-1200 451 SEC-1201 452 SEC-1202 452 SEC-1203 452 SEC-1250 453 SEC-1251 453 SEC-1253 453 SEC- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 42
SEC-1319 459 SEC-1320 459 SEC-1321 459 SEC-1322 460 SEC-1323 460 SEC-1324 460 SEC-1325 460 SEC-1326 461 SEC-1327 461 SEC-1328 461 SEC-1329 462 SEC-1330 462 SEC-1331 462 SEC-1332 462 SEC-1333 463 SEC-3035 463 SEC-3036 463 SEC-3037 464 SEC-3038 464 SEC-3039 464 SEC-3050 464 SEC- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 43
SPC-2001 472 SPC-2002 472 SPC-2003 472 SPC-2004 472 SPC-2005 473 SPC-2006 473 SPC-2007 473 SPC-2008 473 SPC-2009 474 SPC-2010 474 SPC-2011 474 SPC-2012 474 SPC-3001 475 SPC-3002 475 SPC-3003 475 SPC-3004 475 SPC-3005 476 SPC-3006 476 SPC-3007 477 SPC-3008 477 SPC-3009 477 SPC- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 44
SPM-1009 483 SPM-1010 483 Chapter 79 SS System Messages SS-1000 485 SS-1001 485 SS-1002 485 SS-1003 486 Chapter 80 SULB System Messages SULB-1001 487 SULB-1002 487 SULB-1003 487 SULB-1004 488 SULB-1005 488 SULB-1006 488 SULB-1007 488 SULB-1008 489 SULB-1009 489 SULB-1010 495 SULB - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 45
SULB-1037 500 Chapter 81 SWCH System Messages SWCH-1001 501 SWCH-1002 501 SWCH-1003 501 SWCH-1004 502 SWCH-1005 502 SWCH-1006 502 SWCH-1007 502 SWCH-1008 503 SWCH-1009 503 SWCH-1010 503 SWCH-1011 504 Chapter 82 SYSC System Messages SYSC-1001 505 SYSC-1002 505 SYSC-1003 505 SYSC- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 46
TRCE-1004 512 TRCE-1005 512 TRCE-1006 512 TRCE-1007 513 TRCE-1008 513 TRCE-1009 513 TRCE-1010 513 TRCE-1011 514 TRCE-1012 514 Chapter 86 TRCK System Messages TRCK-1001 515 TRCK-1002 515 TRCK-1003 515 TRCK-1004 515 TRCK-1005 516 TRCK-1006 516 Chapter 87 TS System Messages TS-1001 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 47
WEBD-1002 525 WEBD-1004 525 WEBD-1005 525 WEBD-1006 526 WEBD-1007 526 WEBD-1008 526 Chapter 91 ZOLB System Messages ZOLB-1001 527 Chapter 92 ZONE System Messages ZONE-1002 529 ZONE-1003 529 ZONE-1004 529 ZONE-1005 530 ZONE-1006 530 ZONE-1007 531 ZONE-1008 531 ZONE-1010 531 ZONE- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 48
ZONE-1034 537 ZONE-1035 537 ZONE-1036 537 ZONE-1037 538 ZONE-1038 538 ZONE-1039 538 ZONE-1040 538 ZONE-1041 539 ZONE-1042 539 ZONE-1043 539 ZONE-1044 539 ZONE-1045 540 ZONE-1046 540 ZONE-1047 540 ZONE-1048 540 ZONE-1049 541 ZONE-1050 541 ZONE-1051 541 ZONE-1052 541 ZONE-1053 542 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 49
CONF-1020 551 CONF-1022 551 Chapter 92 AUDIT FCIP System Messages FCIP-1002 553 FCIP-1003 553 Chapter 93 AUDIT FICU System Messages FICU-1011 555 FICU-1012 555 Chapter 94 AUDIT FW System Messages FW-3001 557 Chapter 95 AUDIT HTTP System Messages HTTP-1002 559 HTTP-1003 559 Chapter - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 50
SEC-3012 568 SEC-3013 568 SEC-3014 569 SEC-3015 569 SEC-3016 569 SEC-3017 570 SEC-3018 570 SEC-3019 570 SEC-3020 570 SEC-3021 571 SEC-3022 571 SEC-3023 571 SEC-3024 572 SEC-3025 572 SEC-3026 572 SEC-3027 572 SEC-3028 573 SEC-3029 573 SEC-3030 573 SEC-3031 574 SEC-3032 574 SEC- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 51
SEC-3051 578 Chapter 99 AUDIT SNMP System Messages SNMP-1004 579 SNMP-1005 579 SNMP-1006 579 Chapter 100 AUDIT SULB System Messages SULB-1001 581 SULB-1002 581 SULB-1003 581 SULB-1004 582 SULB-1009 582 SULB-1010 588 SULB-1017 588 SULB-1018 588 SULB-1020 589 SULB-1021 589 SULB-1023 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 52
UCST-1024 596 UCST-1025 596 UCST-1026 596 UCST-1027 596 Chapter 103 AUDIT ZONE System Messages ZONE-3001 599 ZONE-3002 599 ZONE-3003 599 ZONE-3004 600 ZONE-3005 600 ZONE-3006 600 ZONE-3007 601 ZONE-3008 601 ZONE-3009 601 ZONE-3010 601 ZONE-3011 602 ZONE-3012 602 ZONE-3013 602 ZONE- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 53
which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 54
• Brocade 4018 switch • Brocade 4020 switch • Brocade 4024 switch • Brocade 4100 switch • Brocade 4900 switch • Brocade 5000 switch • Brocade 5100 switch • Brocade 5300 switch • Brocade 7500 Extension Switch • Brocade 7500E Extension Switch • Brocade 7600 switch • Brocade 48000 director • Brocade - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 55
For readability, command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In a command is case sensitive. Command syntax conventions Command syntax in this manual follows these conventions: command --option, option -argument, arg [ ] - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 56
in this manual. They damage to hardware, firmware, software, or data password. For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through: http://www.amazon.com For additional Brocade documentation, visit the Brocade - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 57
help Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information available: 1. General Information • Switch model • Switch operating system version • Error numbers and messages - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 58
. • If you cannot use the wwn command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX, access the numbers on the WWN cards by removing the Brocade logo plate at the top of the nonport side of the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 59
13 Overview of System Messages This guide supports Fabric OS v6.2.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric. The messages are organized first by event type, reliability, availability, and serviceability log (RASLog) or AUDIT, and then - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 60
for more information. Event Auditing Event auditing is designed to support post-event audits and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware downloads, and certain types of fabric events. Fabric OS versions - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 61
login/logout, passwords, ACLs): default firmware supports the standard syslogd functionality. Configuring for syslogd involves configuring the host, enabling syslogd on the Brocade model, and, optionally, setting the facility level. For the Brocade Guide. Fabric OS Message Reference 3 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 62
. When the log is full, the newest log entries overwrite the oldest log entries. Port logs capture switch-to-device, device-to-switch, switch-to-switch, some device A-to-device B, and control information. Port logs are not persistent and are lost over power cycles and reboots. Run the portLogShow - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 63
recipients to default values. agtCfgSet Power-On Self-Test) configuration. errClear Clears all error log messages for all switch the port log to the specified number of entries. portLogShow Displays the supportFtp Sets, clears, or displays support FTP parameters or a time interval to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 64
. This output is used by your switch service provider to diagnose and correct problems with the switch. The output from this command is is a reference to the blade within the switch platform, e.g.,Brocade 7500 and AP7600 contain FR4-18i and FA4-18 blades respectively. traceDump Displays, initiates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 65
speed. Type to continue, Q to stop: Clearing the System Message Log To clear the system message log for a particular switch instance: 1. Log in to the switch as admin. 2. Use the errClear command to clear all messages from memory. NOTE For products that have a single processor, all error - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 66
was generated on the switch. The RASLog subsystem supports an internationalized timestamp format base on the "LOCAL" setting. The message module and number. These values uniquely identify each message in the Fabric OS and reference the cause and actions recommended in this manual. Note that not all - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 67
number can be reset to 1 using the errClear command. The sequence number is persistent across power cycles and switch switch name. The defined switch name or the chassis name of the switch. This value is truncated if it exceeds 16 for post event auditing and problem determination. Audit event message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 68
The system time (UTC) when the message was generated on the switch. The RASLog subsystem will support an internationalized timestamp format base on the "LOCAL" setting. Message Module and Message Number The message module and number. These values uniquely identify each message in the Fabric OS and - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 69
as general guidelines for troubleshooting. For all cases mode unless the failed power supply is replaced or About the Problem 12 •Support 12 •Panic Dump and Core Dump Files 12 •Trace Dumps 13 •supportSave Command 13 Looking Up a System Message Error messages in this manual - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 70
Run the errDump command on each logical switch. 6. Run supportFtp (as needed) to Brocade DCX, 12000, 24000, or 48000) 13. What and when were the last actions or changes made to the system? Support Fabric OS creates a number of files that can help support personnel troubleshoot and diagnose a problem - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 71
intended for support personnel use only. Trace Dumps The Fabric OS produces trace dumps when problems are switch platform, for example: Brocade DCC contains FC8-48, FC9-32, and FC8-16 blades. Table 5 provides a summary of the system modules for which messages are documented in this reference guide - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 72
specific integrated circuit (ASIC) driver error messages. This is the core edge routing module on the Brocade director platforms. Error messages reporting the problems in the management of the blades in the different slots of the chassis. CNM (Cluster Node Manager ) is a software daemon module of - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 73
port (CUP) for the switch/director. These messages can mean anything fabric. Fabric OS I/O kernel library module. FLOD is a part of the fabric shortest path first (FSPF) protocol that handles service. A component is a module in the Fabric OS, implementing a related set of functionality. A service - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 74
configurations not only switch wide, but also indicate problems Blade Manager (bmd) • Common Access Layer (cald) • Diagnostics daemon (diagd) • Environment Monitor (emd) • EVM daemon (evmd) • Exchange Service Support daemon (snmpd) • Time Service daemon (tsd) • TRACE daemon (traced) • Track Changes - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 75
to the secondary partition and from the active CP blade to the standby CP blade. These messages indicate panic dump trace files have been created. This message indicates hardware problems. A group of messages relating to logical switch creation, deletion and configuration. PORT error messages refer - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 76
If a switch is not responding, RTWR retries 100 times. Storage application services supporting director-class storage firmware upgrades to both CP blades with a single command, as well as nondisruptive code load to all 4.x switches. These messages might display if there are any problems - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 77
's Guide. Time Service provides fabric time-synchronization by synchronizing all clocks in the fabric to the clock time on the principal switch. UCST is a part of problems with the Web Tools module. Indicates problems with the zone library module. The zone module messages indicate any problems - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 78
1 System Module Descriptions 20 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 79
RASLog Messages Section I This section provides the RASLog messages, including: •AG System Messages 25 •AUTH System Messages 33 •BKSW System Messages 47 •BL System Messages 49 •BLL System Messages 63 •BM System Messages 65 •C2 System Messages 71 •CDR System Messages 73 •CER System Messages - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 80
•FSS System Messages 215 •FSSM System Messages 219 •FW System Messages 221 •HAM System Messages 297 •HAMK System Messages 301 •HIL System Messages 303 •HLO System Messages 317 •HMON System Messages 319 •HTTP System Messages 321 •IBD System Messages 323 •IBPD System Messages 325 •ICPD - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 81
•RTWR System Messages 403 •SAS System Messages 405 •SCN System Messages 407 •SEC System Messages 409 •SNMP System Messages 467 •SPC System Messages 471 •SPM System Messages 481 •SS System Messages 485 •SULB System Messages 487 •SWCH System Messages 501 •SYSC System Messages 505 •SYSM - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 82
- HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 83
. • Some blades and ports in a switch may not support NPIV. NPIV functionality can not be enabled on such ports and they will not respond to NPIV requests. Refer to the Access Gateway Administrator Guide, Appendix B, for specific AG-compatibility requirements. • On non-Brocade switches, refer to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 84
as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AG-1005 Message , [AG-1005], ,, WARNING, , FDISC response was dropped because F_Port is offline. Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 85
as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1009 Message , [AG-1009], ,, WARNING, , Sending FLOGI failed on N_Port . Probable Cause Indicates there was - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 86
as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1013 Message , [AG-1013], ,, INFO, , F_Ports mapped to N_Port failed over to other N_Ports. Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 87
needed) to set up automatic FTP transfers; then run the supportsave command and contact your switch service provider. Severity WARNING AG-1016 Message , [AG-1016], ,, INFO, , Failing over F_Ports mapped to N_Port to other N_Ports. Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 88
Cause Indicates that F_Port -to-N_Port mapping has been changed because the switch has come online or some new N_Port/F_Port has come online. Recommended sequence-number>,, WARNING, , Unable to do Preferred-Failover of F_Port . Failover across different fabric is not supported. - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 89
, [AG-1025], ,, ERROR, , Port group switch to display that the Trunk Area is Action assigned to all ports in the system and run porttrunkarea --enable to reconfigure the Trunk Area. Severity ERROR AG-1026 Message , [AG-1026], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 90
then run the supportSave command and contact your switch service provider. Severity WARNING AG-1027 Message , [AG-1027], ,, WARNING, , Unable to handle No action is required. Action Severity INFO 32 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 91
needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1003 Message , [AUTH-1003], ,, INFO, , type has been successfully set to . Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 92
command and contact your switch service provider. Severity WARNING AUTH-1007 Message Probable Cause , [AUTH-1007], ,, ERROR, , The proposed authentication protocols are not supported: port . Indicates that the proposed authentication - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 93
>,, ERROR, , Failed to initialize security policy: switch , error . Probable Cause Indicates an internal problem with the Secure Fabric OS. Recommended Action Reboot or power cycle the switch. If the message persists, run supportFtp (as needed) to set up - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 94
supportSave command and contact your switch service provider. Severity WARNING AUTH-1014 Message , [AUTH-1014], , FFDC, ERROR, , Invalid port value to : port . Probable Cause Indicates an internal problem with the Secure Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 95
the supportSave command and contact your switch service provider. Severity ERROR AUTH-1018 Message , [AUTH-1018], ,, ERROR, , Invalid value to check protocol type: port . Probable Cause Indicates an internal problem with the Secure Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 96
contact your switch service provider. Severity INFO AUTH-1022 Message , [AUTH-1022], ,, ERROR, number>. Probable Cause Indicates that the authentication process failed to extract a particular value from the receiving payload. Recommended Action Usually this problem - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 97
command and contact your switch service provider. Severity ERROR AUTH-1026 Message , [AUTH-1026], ,, WARNING, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 98
the supportSave command and contact your switch service provider. Severity ERROR AUTH-1029 Message , [AUTH-1029], ,, ERROR, , Failed failed to get memory. Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 99
replay attacks. Recommended Action Usually this problem is transient. The authentication might fail. switch service provider. Severity ERROR AUTH-1033 Message , [AUTH-1033], ,, ERROR, , Disable port due to unauthorized switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 100
command and contact your switch service provider. Severity ERROR AUTH-1035 Message , [AUTH-1035], ,, ERROR, . Probable Cause Indicates that the switch received an unexpected authentication message. Recommended Action Usually this problem - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 101
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1037 Message , [AUTH-1037], ,, ERROR, , Failed to response for : init_len - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 102
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1042 Message Probable Cause , [AUTH-1042], ,, ERROR, , Port has been disabled, because authentication failed with code ' - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 103
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1043 Message , [AUTH-1043], ,, ERROR, , Failed to enforce device authentication mode:(error: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 104
3 AUTH-1044 46 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 105
Messages Chapter 4 BKSW-1003 Message , [BKSW-1003], ,, WARNING, , kSWD: . Probable Cause Indicates any core file information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 47 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 106
4 BKSW-1003 48 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 107
correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Note that any reference seen to slot 0 is a reference to the blade within the switch platform, e.g.,Brocade 7500 and AP7600 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 108
Cause Indicates a faulty blade in the specified slot number. Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that blade does not have hardware problems. Run the diagPost - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 109
. Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 110
to verify that the blade or switch does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot or power cycle the switch. If the message persists - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 111
and slotPowerOn commands. On a nonbladed switch, reboot or power cycle the switch. If the message persists, replace the blade or the nonbladed switch. Severity ERROR BL-1013 Message , [BL-1013], ,, ERROR, , bport port is faulted. status=0x - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 112
the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors are encountered again: • On the Brocade DCX, 24000, and 48000, replace the blade field-replaceable unit (FRU). • On the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 113
hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade. Severity CRITICAL BL-1017 Message , [BL-1017], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 114
problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the switch. Severity CRITICAL BL-1021 Message , [BL-1021], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 115
Action Reboot or power cycle the blade. If the message persists, replace the blade. Severity CRITICAL BL-1024 Message , [BL-1024], ,, INFO, , All ports on the blade in slot will be reset as part of the firmware upgrade. Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 116
and run the diagPost command to ensure Action Power-On Self-Test (POST) is enabled. If problem persists, replace switch. Severity CRITICAL BL-1027 Message , [BL-1027], ,, CRITICAL, , Blade in slot faulted, boot failed; status 0x - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 117
, [BL-1030], ,, INFO, , All GigE/FCIP Virtualization/FC Fastwrite ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 118
power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power timestamp>, [BL-1036], ,, CRITICAL, , Faulting 8G blade in slot = due to incompatible stag mode - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 119
BL-1037 5 BL-1037 Message , [BL-1037], ,, CRITICAL, , Faulting chip in slot = , miniS = ,port = due to BE/BI port fault. Probable Cause Fault the chip and disable all the ports on that chip. Recommended No action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 120
5 BL-1037 62 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 121
number> port as faulty (reason: ) Probable Cause Indicates a blade regulation problem was reported on the specified slot number. The blade = FDET interrupt • 14 = Interrupt suspended • 15 = Filter LISTD error • 16 = Unknown filter LIST error • 17 = Wait for LPC open state • 18 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 122
6 BLL-1000 If the message persists, replace the blade. Severity CRITICAL 64 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 123
download is supported between the versions. As the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP blade. If needed, send the AP blade back to the factory for a firmware update. Severity ERROR BM-1002 Message , [BM-1002], ,, INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 124
slotPowerOn commands or reseat the affected blade. On the Brocade Action 7500 or 7600, switch off and on all primary power to power-cycle the unit. Severity WARNING BM-1006 Message , [BM-1006], ,, INFO, , Blade is not configured. Persistently disabling - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 125
and slotPowerOn commands or reseat the affected blade. On the Brocade Action 7500 or 7600, switch off and on all primary power in order to power-cycle the unit. Severity WARNING BM-1010 Message Probable Cause , [BM-1010], ,, INFO, , Resetting port - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 126
On the Brocade 7500 or 7600, switch off and on all primary power to power-cycle the unit. Action Severity WARNING BM-1054 Message , [BM-1054], ,, INFO, , AP firmware is not consistent with system firmware . Auto-leveling - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 127
Severity INFO BM-1058 Message , [BM-1058], ,, WARNING, , Download of AP firmware failed for the switch. Reissue firmwaredownload to recover. Probable Cause Indicates the automatic firmware upgrade on the application processor (AP) has failed, because the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 128
7 BM-1058 70 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 129
C2-1002 Message , [C2-1002], ,, ERROR, , Port chip faulted due to an internal error. Probable Cause Internal error. All the ports on the blade/switch will be disrupted. Recommended For a bladed system, perform slotpoweroff and slotpoweron on - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 130
>,, ERROR, , Rate limit configuration is not effective on S() user port because QoS license is not present. Probable Cause Indicates that the switch does not have the QoS license added. Rate Limit is a licensed feature and requires QoS license. Recommended - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 131
and slotPowerOn commands on the blade to recover Action the system. For a non-bladed system, perform fastBoot on the switch to recover the system. Severity ERROR CDR-1003 Message , [CDR-1003], , FFDC, CRITICAL, , , HW ASIC chip - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 132
[CDR-1004], , FFDC, ERROR, , , : invalid DMA ch pointer, chan:, good_addr:0x, at the next maintenance window. If the problem Action persists, replace the blade. Severity ERROR 74 Fabric OS Message Reference 53-1001157- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 133
], ,, ERROR, , HA Sync broken, since standby Advanced Performance Tuning module does not support FICON Management Server is broken, because there is downlevel firmware loaded on the standby CP. The standby CP does not support the Advanced Performance Tuning module when - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 134
10 CER-1001 76 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 135
command followed by the slotPowerOn Action command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch. Severity ERROR CHASSIS-1004 Message , [CHASSIS-1004], ,, ERROR, , Blade attach failed during recovery, disabling slot = - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 136
system-name>, Diag attach failed during recovery, disabling slot = . Probable Cause Indicates that the Diag blade attach has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command. On - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 137
command. Refer to the Action Fabric OS Command Reference Manual for more information on this command. Severity WARNING CNM-1004 Message , [CNM-1004], ,, INFO, , iSCSI service is on the switch. Fabric OS Message Reference 79 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 138
12 CNM-1005 Probable Cause Indicates that the Crypto service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO CNM-1005 Message , [CNM-1005], ,, INFO, , Posting event CNM_EVT_GRP_LEADER_ELECTED Name [ - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 139
offline, rejoin the node to the encryption group (EG). Action Severity INFO CNM-1012 Message Probable Cause , [CNM-1012], ,, INFO, ,Posting event CNM_EVT_EG_DELETED. Indicates that the encryption group (EG) is deleted. Fabric OS Message Reference 81 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 140
group (EG) is split. Recommended No action is required. Action Severity INFO CNM-1014 Message , [CNM-1014], ,, INFO, ,Posting event Node Admission Control passed, admitting node []. Probable Cause Indicates that the Node Admission Control was - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 141
Indicates that the node is already a member. Recommended No action is required. Action Severity INFO CNM-1019 Message , [CNM-1019], ,, INFO, , Join Rejected by GL node, fix certificate and later add member node from GL node, or reboot the member node - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 142
not allowed on a group leader (GL) node. Recommended No action is required. Action Severity INFO CNM-1023 Message , [CNM-1023], ,, INFO, , Group Leader node eject is not allowed. Probable Cause Indicates an eject operation is not allowed in group leader - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 143
. Action Severity INFO CNM-1026 Message , [CNM-1026], ,, INFO, , Received HBT Message with version mismatch, Received Hdr version Expected Hdr version Upgrade the firmware or delete the Node [] from the EG. Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 144
certificate file for the node already exists. Recommended No action is required. Action Severity INFO CNM-1029 Message , [CNM-1029], ,, INFO, , Certfile content does not match the cert sent by GL. Probable Cause Indicates that the contents of the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 145
the cluster is in a degraded state. Recommended No action is required. Action Severity INFO CNM-1034 Message , [CNM-1034], ,, INFO, , All the defined nodes in the Encryption Group are ONLINE. Cluster is in converged state. Probable Cause Indicates that - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 146
arbitration is lost. Recommended No action is required. Action Severity INFO CNM-1040 Message Probable Cause , [CNM-1040], ,, INFO, , Split-Brain Arbitration won, Majority WWN/GL Node, remote_wwn:local_wwn . Indicates that split arbitration is lost - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 147
No action is required. Action Severity INFO CNM-1041 Message , [CNM-1041], ,, INFO, , Updating persistent Cluster DB, please avoid powering off the switch. Probable Cause Indicates the system is updating the persistent database. Recommended No action is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 148
12 CNM-1044 Recommended No action is required. Action Severity INFO 90 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 149
, message strings, is the description of the classes of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in the description. Recommended No action is required. Action Severity INFO CONF-1001 Message , [CONF-1001], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 150
or more parameters that require the switch to be disabled. Recommended Disable the switch and try to download the configuration. Action Severity INFO CONF-1030 Message , [CONF-1030], ,, WARNING, , Configuration database full, data not committed (key: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 151
Chapter CTAP System Messages 14 CTAP-1001 Message , [CTAP-1001], ,, INFO, , Key acquisition for . Probable Cause Indicates that a change in the tape pool database has triggered the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 152
14 CTAP-1001 94 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 153
>,, INFO, , re-key , LUN SN: .\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates the First - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 154
re-key session was still active. Recommended No action is required. Action Severity INFO CVLC-1005 Message , [CVLC-1005], ,, INFO, , There is no LUN's found from the target.\nContainer: , Initiator: , LUN ID - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 155
mode but there is no valid license. Recommended Obtain license for non-Brocade mode. Action Severity ERROR CVLC-1011 Message , [CVLC-1011], ,, ERROR, , Third party license is required for encryption LUN in third party mode.\nContainer: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 156
Indicates that the encryption engine is unable to retrieve the key record base on the key ID found in the metadata. Recommended No action available. Action Severity ERROR CVLC-1015 Message , [CVLC-1015], ,, ERROR, , LUN is set to read only mode. Reason: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 157
is set back to read/write. Recommended No action is required. Action Severity INFO CVLC-1017 Message , [CVLC-1017], ,, INFO, , Event: .\nContainer: , Initiator: , LUN ID: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 158
is ignored because metadata exists on the LUN. Recommended No action is required. Action Severity INFO CVLC-1022 Message , [CVLC-1022], ,, INFO, , User provided key ID is ignored while data state is clear text.\nContainer: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 159
or power cycle the switch. Severity ERROR CVLM-1002 Message , [CVLM-1002], ,, ERROR, , Failed to initialize rc = . Probable Cause Indicates that an initialization of a module within the CVLMD failed. Recommended Download a new firmware - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 160
the Fabric OS Command Reference Manual for more information on this command. Severity WARNING CVLM-1005 Message , [CVLM-1005], ,, INFO, , Crypto service is on the switch. Probable Cause Indicates that the Crypto service is enabled or disabled on - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 161
16 CVLM-1009 Probable Cause Indicates that the member of HAC is not in the fabric. Recommended Check the ISL port connected to the fabric. Action Severity WARNING CVLM-1009 Message , [CVLM-1009], ,, INFO, , The member ( ) of HAC - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 162
16 CVLM-1012 Recommended No action is required. Action Severity INFO 104 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 163
, [EM-1001], , FFDC, CRITICAL, , the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Action On Brocade 24000 and 48000, try reseating the specified FRU. Reboot or power cycle the switch. Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 164
string and an optional number to identify the unit, slot, or port. The Brocade 3250 has one power supply and three fans, and the Brocade 3850 has two power supplies and four fans. Values for the individual fans and power supplies for these switches might display, but these parts cannot be replaced - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 165
the faulty slot or the switch for nonbladed switches. Recommended Action There is most likely a voltage hardware problem on the blade or motherboard of the switch. For the Brocade DCX, 24000 and 48000, replace the blade field-replaceable unit (FRU). For the Brocade 3900 replace the motherboard FRU - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 166
, replace the FRU. Refer to the Brocade 48000 Hardware Reference Manual for more information about chassisConfig modes and supported blades. Severity CRITICAL EM-1010 Message , [EM-1010], , FFDC, CRITICAL, , Received unexpected power down for But - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 167
problems on the switch. Recommended Action On Brocade DCX, 24000 and 48000, try reseating the indicated field-replaceable unit (FRU). If the message persists, reboot or power cycle the switch EM-1014 Message , [EM-1014], ,, ERROR, , Unable to read sensor - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 168
to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING EM-1017 Message , [EM-1017], ,, WARNING, , Uncommitted WWN change detected. Cold reboot required. Probable Cause Indicates that - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 169
option is not supported by the firmware on the standby power cycle the switch. If the message still persists, replace the WWN card, or the switch (for nonbladed switches). Severity CRITICAL EM-1029 Message , [EM-1029], ,, WARNING, , , a problem - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 170
upper thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate hardware manual for instructions on inserting the switch blades. Severity ERROR EM-1033 Message , [EM-1033], ,, ERROR, , CP in - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 171
wide name (WWN) card, then default WWN and IP addresses are used for the switch. Recommended Action Reseat the FRU card. If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 172
The specified FRU is not responding to commands and should be replaced. Action Severity WARNING EM-1044 Message , [EM-1044], ,, WARNING, , Can't power on , its logical switch is shut down 114 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 173
power supplies for redundancy. Severity WARNING EM-1046 Message , [EM-1046], ,, WARNING, , Sysctrl reports error status for blade ID for the blade in slot - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 174
is required. Action Severity INFO EM-1048 Message , [EM-1048], ,, INFO, , I2C access recovered: state Probable Cause Indicates that the I2C bus problems have been resolved and I2C access to the field-replaceable unit (FRU) has - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 175
This message is valid for only the Brocade 4100, 4900, 5000, 7500, and AP7600. Recommended Replace the defective small form-factor pluggable (SFP). Action Severity WARNING EM-1057 Message , [EM-1057], ,, WARNING, , Blade: is getting reset: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 176
or blade will be faulted and should be replaced. Severity WARNING EM-1058 Message , [EM-1058], ,, WARNING, , Switch gets reset: Probable Cause Indicates the switch is being automatically reset because of a known resetable transient problem - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 177
of particular types are in the system. Recommended Remove the faulted blade. Action Severity CRITICAL EM-1064 Message , [EM-1064], ,, CRITICAL, , Blade: is being powered off (based on user configuration) upon receiving a HW ASIC ERROR, reason - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 178
, and you have selected to power off the problem blade when such a condition occurred. Recommended Contact support. Action Severity CRITICAL EM-1065 Message , [EM-1065], ,, CRITICAL, , SSAS Virtualization Services are not available due to incompatibility - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 179
or hardware problems on the switch. Recommended Reboot or power cycle the switch. If the message persists, collect switch information using the Action supportsave command, and contact your switch service provider. Severity ERROR EM-1069 Message , [EM-1069], ,, INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 180
FRU. On nonbladed switches, reboot or power cycle the switch. If the problem persists: • Run the systemverification command to verify that the switch does not have hardware problems. Refer to theFabric OS Reference Manual for more information on this command. • On bladed systems, replace the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 181
Action Discontinue the firmware download, identify the downlevel switch or switches that do not support the Coordinated HotCode protocol, and upgrade the downlevel switches. Then, restart the firmware download on this switch. Note that upgrading a downlevel Brocade switch in a mixed interop - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 182
domain id>. Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected resume message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 183
Chapter EVMD System Messages 19 EVMD-1001 Message , [EVMD-1001], ,, WARNING, , Event could not be sent to remote proxy. = Probable Cause Indicates the event could not be sent to remote proxy. This could happen if the remote - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 184
19 EVMD-1001 126 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 185
Cause Indicates that an internal link service (ILS) information unit of invalid size has been received. The neighbor switch has sent a payload with an invalid size. Recommended Action Investigate the neighbor switch for problems. Run the errShow command on the neighbor switch to view the error log - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 186
switch service provider. Severity WARNING FABR-1004 Message , [FABR-1004], ,, WARNING, , port: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 187
and contact your switch service provider. Severity WARNING FABR-1007 Message , [FABR-1007], ,, WARNING, < message occurs with FABR-1005, the problem is usually transitory. Otherwise, this message is rare and usually indicates a problem with the Fabric OS. The error - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 188
a problem with the Fabric OS. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING FABR-1011 Message , [FABR-1011], , FFDC - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 189
up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL FABR-1014 Message , [FABR-1014], , FFDC, ERROR, , Port Disabled: Insistent Domain ID could not be obtained - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 190
switch using the fabricPrincipal command. The message notifies you that the switch failed to become the principal switch because of one of the following reasons: • The switch -number>, FFDC, CRITICAL, , Critical fabric size () exceeds supported configuration ( - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 191
licensed limit. Contact your switch provider to obtain a full fabric license. Severity CRITICAL FABR-1022 Message , [FABR-1022], , FFDC, CRITICAL, , Fabric size () exceeds supported configuration (). Fabric limit timer - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 192
changed to within the licensed limit. Contact your switch provider to obtain a full fabric license. Severity CRITICAL FABR-1023 Message , [FABR-1023], ,, INFO, , Fabric size is within supported configuration (). Fabric limit timer ( - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 193
the buffer credits are fixed, based on the port configuration information. In this mode, the buffer credits are negotiated as part of exchange link parameter (ELP Message , [FABR-1032], , WARNING, , Remote switch with domain ID and switchname - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 194
Master Trunk Area, or disable Trunk Area. You must manually enable the port or the port remains disabled forever. Refer to the Admin Guide for more information. Severity INFO FABR-1036 Message , [FABR-1036], , INFO, , F_port trunks are only allowed on - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 195
F_port trunking on the port. Action Severity INFO FABR-1039 Message , [FABR-1039], , WARNING, , Invalid domain id zero received from principal switch (domain id=). Probable Cause Indicates the invalid domain ID zero has been received - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 196
the switch Action firmware to a VF-capable firmware. Severity ERROR FABR-1045 Message Probable Cause , [FABR-1045], , ERROR, , Detected Base Switch conflict with remote (not neighbor) switch (domain ), BS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 197
that the remote switch has a Base Switch attribute conflict with the local switch. All the E_ports directly connected to the conflicting switch are disabled. Recommended Make sure that all the switches in the fabric have the same Base Switch attribute or upgrade the Action switch firmware to a VF - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 198
20 FABR-1046 140 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 199
Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1004 Message , [FABS-1004], ,, WARNING, , process - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 200
media state to blade driver Recommended Action If the message is isolated, monitor the error messages on the switch. If the error problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 201
internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1011 Message Probable Cause , [FABS-1011], ,, ERROR, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 202
usually an internal Fabric OS problem. Recommended Action Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR FABS-1013 Message , [FABS-1013], ,, ERROR, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 203
enabled. This is usually an internal Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR Fabric OS Message Reference 145 53-1001157 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 204
21 FABS-1015 146 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 205
Action The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade can be changed using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmwareDownload is supported between the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 206
22 FBC-1001 148 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 207
>, FIPS failed; algo= type= slot=. Probable Cause Indicates that a FIPS failure has occured and requires faulting the blade or switch. Recommended Retry the command again. Action Severity ERROR FCIP-1002 Message , [FCIP - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 208
-name>, Tape Read Pipelining is being disabled slot () port () tunnel (). Probable Cause Indicates that the FOS version on the remote end of the tunnel does not support Tape Read Pipelining. Recommended No action is required. Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 209
-number>, FFDC, CRITICAL, , System is low on memory and has failed to allocate new memory. Probable Cause Indicates that the switch is unit (IU). Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over and - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 210
24 FCMC-1001 152 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 211
,, INFO, , Probing failed on which is possibly a private device which is not supported in this port type Probable Cause Indicates that private devices will not respond to the switch port login (PLOGI) during probing. Recommended Action The Brocade DCX - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 212
25 FCPD-1003 154 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 213
switch will automatically reboot. For a bladed switch, the active CP blade will Number> has been disabled since switch requires authentication when device authentication policy is set to ON. Probable Cause Indicates a device which does not support authentication has tried to log in to the switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 214
26 FCPH-1002 156 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 215
port. Recommended No action is required. Action Severity INFO FCR-1002 Message , [FCR-1002], ,, INFO, , FC router proxy device in edge deleted at port . Probable Cause Indicates that a proxy device in the edge fabric has been deleted at the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 216
Recommended No action is required. Action Severity INFO FCR-1007 Message , [FCR-1007], ,, INFO, , FC router LSAN zone deleted at port . Probable Cause Indicates that a logical storage area network (LSAN) zone attached to the specified port - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 217
fabric attached to the specified port. Recommended No action is required. Action Severity INFO FCR-1011 Message , [FCR-1011], ,, INFO, , Remote LSAN zone updated in domain . Probable Cause Indicates that a logical storage area network (LSAN - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 218
FCR fabric no longer reachable at port id () fabric ID . Probable Cause Indicates that a fabric is no longer accessible through the backbone fabric. This may be caused by a link or switch failure. Recommended No action is required. Action Severity INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 219
excess logical storage area network (LSAN) zones or devices until the number of proxy devices exported is within the range allowed by the port many proxy devices are created in the fabric with the port resource problem. LSAN zones are removed using standard zoning commands such as zoneShow, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 220
(LSAN) zones within the MetaSAN exceeds the local LSAN zone database limitations. Recommended Remove excess device entries within LSAN zones so that the number of devices is within the range Action of the local zone database limitations. Severity WARNING FCR-1022 Message , [FCR-1022 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 221
. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical storage area network (LSAN) devices and fabrics, or there are highly dynamic changes to EX_Port connectivity - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 222
as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical storage area network (LSAN) devices and fabrics, or there are highly dynamic changes to EX_Port or - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 223
) came online in the specified fabric. Recommended No action is required. Action Severity INFO FCR-1031 Message , [FCR-1031], ,, INFO, , Physical device went offline in fabric . Probable Cause Indicates that the physical device - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 224
(LSAN) zone in the backbone fabric. Recommended No action is required. Action Severity INFO FCR-1036 Message , [FCR-1036], ,, INFO, , LSAN zone enabled in the backbone fabric. Probable Cause Indicates that the specified logical storage area - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 225
of cfg/zone/alias entries created in a local fabric is greater than the local switch's zone database limitations. Recommended Remove excess cfg/zone/alias entries so that the number of logical storage area network (LSAN) Action zones created is within the range of the local database limitations - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 226
the supportShow command, and contact your switch service provider. Severity ERROR FCR-1049 Message Probable Cause , [FCR-1049], ,, ERROR, , EX port () received an ELP command that is not supported. Indicates an incoming exchange link protocol - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 227
commands to enable and disable the port. If the problem persists contact your switch service provider. Severity ERROR FCR-1053 Message , [FCR-1053], ,, WARNING, , Port was disabled, . Probable Cause Indicates that the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 228
INFO FCR-1056 Message , [FCR-1056], ,, INFO, , Switch with front domain ID does not support backbone to edge imports. Probable Cause Indicates that a switch that does not support backbone-to-edge routing is running in the MetaSAN - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 229
configuration on the local switch using the portCfgShow command to verify that the VC Link Init is disabled, if the remote switch is configured in R_RDY timestamp>, [FCR-1062], ,, INFO, , Port disabled, system only supports EX/VEX_ports. - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 230
FCR-1063 Probable Cause Indicates that the maximum number of supported EX_ports or VEX_ports was exceeded. To enable the INFO FCR-1063 Message , [FCR-1063], ,, INFO, , Fabric for switch with domain ID: mismatch with local fabric ID - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 231
, then merge the fabrics and manually re-enable the port. If number of zone configurations created in the connected fabric exceeds the maximum number supported by the Fibre Channel. The limit includes both active and configured information that is part that the FC Routing service is disabled by the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 232
enabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action Severity INFO FCR-1070 Message , [FCR-1070], ,, INFO, , The FC Routing configuration is set to default. Probable Cause Indicates that the FC - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 233
a switch in the backbone/edge that supports different limit of logical storage area network (LSAN) zones was detected. Recommended Action Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest supported LSAN zone limits. Please make sure that total number - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 234
supported front domains. Action Severity ERROR FCR-1077 Message , [FCR-1077], ,, WARNING, , Port rejected fabric binding request/check from the M-Model switch; - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 235
the domain . Probable Cause During the Coordinated HotCode protocol, a switch in the fabric did not accept the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this issue. Recommended Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 236
Message Probable Cause , [FCR-1086], ,, ERROR, , HA sync lost as remote CP does not support Condor2 based EX_ports. Indicates that the remote control processor (CP) has older firmware, which does not support Condor-based EX_ port. This is causing the loss of - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 237
27 FCR-1087 Recommended Disable Condor2-based EX_ports or upgrade the remote CP. Action Severity ERROR FCR-1087 Message , [FCR-1087], ,, ERROR, , ExPort connects to fabric with capability to use XISL domain . Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 238
27 FCR-1089 180 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 239
where: VE - VE Port Number: This number represents the FCIP Tunnel number through its VE Port number. HD - Host switch Domain number: This is a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to. HP - Host Port number: This is a 1 byte - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 240
manually. Recommended No action is required. Action Severity INFO FICN-1006 Message , [FICN-1006], ,, WARNING, , FICON GEPort < 0 or 1 - GE port number> TID - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 241
from the channel as a part of path recovery. Recommended If there was a job failure associated with this event, please contact your vendor's customer support Action for assistance. Severity ERROR FICN-1009 Message , [FICN-1009], ,, INFO, , DevIng - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 242
there was a job or IO failure associated with this event, please contact your vendor's customer Action support for assistance. Severity ERROR FICN-1013 Message , [FICN-1013], ,, INFO, , DevDiskIng:Status=0x - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 243
corruption between the emulation processing components. Recommended Please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1016 Message , [FICN-1016], ,, INFO, , DevIng:Received Logical Path Removed response:Path= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 244
was an unexpected job failure associated with this event, contact your vendor's customer Action support for assistance. Severity ERROR FICN-1021 Message , [FICN-1021], ,, ERROR, , DevTapeEgr:FICON Tape Cancel:Path= Elapsed Time= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 245
unexpected job failure or IO Error associated with this event, contact your vendor's Action customer support for assistance. Severity ERROR FICN-1025 Message , [FICN-1025], ,, ERROR, , DevTapeIng:Auto Sense Data received on Path= Bytes0-0xB=0x - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 246
unexpected job failure or IO Error associated with this event, contact your vendor's Action customer support for assistance. Severity INFO FICN-1027 Message , [FICN-1027], ,, ERROR, , DevTapeIng:Device level exception found for Path=: Oxid=0x - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 247
vendor's Action customer support for assistance. Severity ERROR FICN-1030 Message , [FICN-1030], ,, ERROR, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 248
vendor's customer support for assistance. Action Severity ERROR FICN-1035 Message , [FICN-1035], ,, WARNING, < . This is a part of the FICON path deactivation. Action Severity INFO FICN-1037 Message , [FICN-1037], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 249
This is a part of the FICON path activation. Action Severity INFO FICN-1038 Message , [FICN-1038], ,, ERROR, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 250
to the LPAR. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1042 Message , [FICN-1042], ,, WARNING, , HostTapeIng:FICON Cancel received Path= state=0x - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 251
the path recovery. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity WARNING FICN-1046 Message , [FICN-1046], ,, WARNING, , HostTapeIng:LRJ received on Path= lastCmds=0x - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 252
or write job. Recommended This is an unexpected event; contact your vendor's customer support for assistance. Action Severity WARNING FICN-1049 Message , [FICN-1049], ,, WARNING, , ProcessIngTirData:Lost Logical Path for Path= Index= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 253
This is a part of the XRC session establishment. Action Severity INFO FICN-1052 Message , [FICN-1052], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 254
sent to a device. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1058 Message , [FICN-1058], ,, ERROR, , Error return from frame generation processing for a FICON control unit - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 255
fast path hash table entry. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1062 Message , [FICN-1062], ,, ERROR, , Ingress Abort:Oxid=0x:Path - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 256
there were associated IO errors at the same time as this event, contact your vendor's customer Action support for assistance. Severity INFO FICN-1065 Message , [FICN-1065], ,, INFO, , Egress Abort:Oxid=0x:Unknown Path on - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 257
devices are already in use Action or there is an internal memory leak, contact your vendor's customer support for assistance. Severity WARNING FICN-1067 Message , [FICN-1067], ,, ERROR, , Ingress Abort:Oxid=0x:Abort for CH - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 258
are associated Action IO error messages with this event, please contact your vendor's customer support for assistance. Severity INFO FICN-1071 Message , [FICN-1071], ,, INFO, , HostTapeIngr:Tape Loaded on Path=. Probable Cause Indicates the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 259
tape. Recommended No action is required. Action Severity INFO FICN-1075 Message , [FICN-1075], ,, INFO, , HostTapeIngr:ReadBlkReport:Path=:Emuls=0x:Cmds=0x - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 260
device. Recommended No action is required. Action Severity INFO FICN-1078 Message , [FICN-1078], ,, INFO, , DevTapeEgr:ReadBlkReport:Path=:Emuls=0x:Cmds=0x - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 261
Severity INFO FICN-1081 Message , [FICN-1081], ,, WARNING, , DevTapeIng:LRJ received on Path= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 262
FICON emulated path has logged out from the switch. Recommended This may be an unexpected event, contact your vendor's customer support for assistance. Action Severity WARNING FICN-1084 Message , [FICN-1084], ,, ERROR, , fcFicInit: No DRAM2 memory - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 263
this RNID. The error variable is an internal error number. Recommended Action If this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 264
command. Refer to the Fabric OS Administrator's Guide for information on core PID mode and the Fabric OS Command Reference Manual for information on these commands. Severity WARNING FICU-1005 Message , [FICU-1005], ,, ERROR, , Failed to initialize - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 265
problem. Recommended Action If the message persists, check the memory usage on the switch switch service provider. Severity WARNING FICU-1008 Message , [FICU-1008], ,, WARNING, , FMS mode has been enabled. Ports: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 266
>,, WARNING, , FMS Mode enable failed due to address conflict with port . Probable Cause Indicates that the Fibre Connectivity (FICON) Management Server mode (fmsMode) was not enabled because the specified port which has an address conflict with - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 267
Chapter FKLB System Messages 30 FKLB-1001 Message , [FKLB-1001], ,, WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 268
30 FKLB-1001 210 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 269
length = Probable Cause Indicates that the LSU size exceeds what the system can support. Recommended Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two Action switches. Severity ERROR FLOD-1005 Message , [FLOD-1005], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 270
Severity WARNING FLOD-1006 Message , [FLOD-1006], ,, WARNING, , Transmitting invalid domain ID: Probable Cause Indicates that the transmit LSR contained an invalid domain number. Recommended No action is required; the LSR is discarded - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 271
Chapter FSPF System Messages 32 FSPF-1001 Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range; it does not exist on the switch. Recommended No action is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 272
nonhierarchical fabric. Brocade switches support only section supported, input port = Probable Cause Indicates that the FSPF version is not supported on the specified input port. Recommended Action Update the FSPF version by running the firmwareDownload command to update the firmware - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 273
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FSS-1002 Message , [FSS-1002], ,, WARNING, , Component () sending too many concurrent HA data update - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 274
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR FSS-1005 Message , [FSS-1005], ,, WARNING, , FSS read failure Probable Cause Indicates that the read system call to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 275
to restore the synchronization by issuing the haSyncStart command. If the problem persists, contact your switch service provider. Severity CRITICAL FSS-1008 Message , [FSS-1008], ,, CRITICAL, , FSS Error: . Probable Cause Indicates that - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 276
33 FSS-1011 FSS-1011 Message , [FSS-1011], ,, INFO, , FSS Info: . Probable Cause Indicates that an error has occurred. Recommended No action is required. Action Severity INFO 218 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 277
command to diagnose the problem. If the problem persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FSSM-1004 Message , [FSSM-1004], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 278
fails, the failover will be disruptive. In a switch system, this message is logged when a firmware upgrade/downgrade was invoked. The new firmware version is not compatiable with the current running version. This causes a disruptive firmware upgrade/downgrade. Recommended For a dual CP system, run - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 279
location temperature is within the operational range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Severity WARNING FW-1003 Message , [FW-1003], ,, WARNING, , , is above high boundary - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 280
number>,, INFO, , , is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the internal temperature of the switch . Fan problems typically contribute to temperature problems. Recommended Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 281
. Run the psShow command to view the status of the power supply. If the power supply continues to be a problem, replace the faulty power supply. Severity INFO FW-1010 Message Probable Cause , [FW-1010], ,, WARNING, , , is below low boundary(High - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 282
supply correctly and that it is correctly seated in the Action chassis. If the problem persists, replace the faulty power supply. Severity WARNING FW-1011 Message , [FW-1011], ,, INFO, , , is above high boundary(High=, Low= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 283
. Severity WARNING FW-1035 Message , [FW-1035], ,, WARNING, , , is above high boundary(High=< Current value is . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The receive - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 284
number>,, WARNING, , , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the receive power . Probable Cause Indicates that the receive power value of the small form-factor pluggable (SFP) has - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 285
FW-1041 FW-1041 Message , [FW-1041], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP) has changed - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 286
-1044 FW-1044 Message , [FW-1044], ,, INFO, , , is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the transmit power value of the small form-factor pluggable (SFP - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 287
is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1049 Message , [FW-1049], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 288
>,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the number of times E_Ports have gone down has changed. E_Ports go down each time you remove a cable or small form-factor pluggable (SFP). SFP - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 289
pluggable (SFP). SFP failures also cause E_Ports to go down. E_Port downs might be caused by transient errors. A low number of E_Port failures means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 290
error and might not require troubleshooting. Severity INFO FW-1118 Message , [FW-1118], ,, INFO, , the number of fabric reconfigurations has fallen below the low boundary. The following occurrences can cause a fabric reconfiguration: • Two switches with - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 291
low boundary. Domain ID changes occur when there is a conflict of domain IDs in a single fabric and the principal switch has to assign another domain ID to the switch. A low number of domain ID changes means that the fabric is functioning normally. Recommended No action is required. Respond to this - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 292
to assign another domain ID to the switch. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1125 Message , [FW-1125], ,, INFO, , , value has - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 293
conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports >, Low=). Current value is . Indicates that the number of segmentations has changed from a value outside of the acceptable range to a - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 294
. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports =). Current value is . Probable Cause Indicates that the number of zone changes has fallen below the low boundary. Zone changes occur when there - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 295
, is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the number of zone changes has changed from a value outside of the acceptable range to a value within the acceptable range. Zone changes occur when there - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 296
system-name>, , is above high boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of fabric logins has risen above the high boundary. Fabric logins occur when a port or device initializes with the fabric. The event is called - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 297
or removed. A low number of SFP state changes means that the switch is functioning normally. Recommended No problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 298
physical and hardware problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch is functioning normally - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 299
are not faulty. If you continue to experience synchronization loss errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity INFO FW-1165 Message , [FW-1165], ,, INFO, , , , is below low boundary - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 300
troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity WARNING FW-1167 Message , [FW-1167], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 301
number of signal loss errors means that the switch is functioning normally. Severity INFO FW-1170 Message , [FW-1170], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 302
the low boundary. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 303
the port experiences has fallen below the low boundary. Invalid words usually indicate a hardware problem with an small form-factor pluggable (SFP) or cable. A low number of invalid words means that the switch is functioning normally. Recommended No action is required. Respond to this message as is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 304
number of invalid words that the port experiences has changed from a value outside of the acceptable range to a value within the acceptable range. Invalid words usually indicate a hardware problem user installation. A low number of invalid CRCs means that the switch is functioning normally. Severity - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 305
>, is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the number of invalid cyclic redundancy checks (CRCs) that the port experiences has changed from a value outside of the acceptable range to a value within the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 306
as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1187 Message , [FW-1187], ,, INFO, , , , is between high and low boundaries(High=, Low=). Current value is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 307
, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the number of state changes that the port experiences has changed. The state of the port has changed for one of the following reasons: the port - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 308
, is testing, is faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. A low number of port state changes means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 309
appropriate to the particular policy of the end-user installation. A low Action number of link resets means that the switch is functioning normally. Severity INFO FW-1198 Message , [FW-1198], ,, WARNING, , , , is above high boundary(High - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 310
. You should set your high boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem in this area. A low level of invalid CRC errors means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 311
, temperature fluctuations, and aging equipment. You should set your high boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem in this area. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 312
equipment. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. A low number of CRC errors means that the fabric is functioning normally. The CRC error area of the End-to-End Performance Monitor class helps you - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 313
Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch receives has changed. Receive performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 314
number of end-to-end (EE) word frames that the switch 1248], ,, INFO, < number of end-to-end (EE) word frames that the switch transmits has changed. Transmit performance messages appear due to the number -1249], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 315
boundaries(High=, Low=). Current value is . Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch transmits has changed from a value outside of the acceptable range to a value within the acceptable range. Transmit performance - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 316
value>). Current value is . Probable Cause Indicates that the number of frame types or commands that the port receives has changed from a value IP) addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Run the errShow command to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 317
protocol (IP) addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended No action is required. Action Severity INFO FW-1298 Message , [FW-1298], ,, WARNING, , , is above high boundary(High= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 318
(IP) addresses that are authorized to establish browser connections to the switches in the fabric. Recommended No action is required. Action Severity INFO FW-1302 Message , [FW-1302], ,, WARNING, , , is above high boundary(High= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 319
protocol (IP) addresses that are authorized to establish browser connections to the switches in the fabric. Recommended No action is required. Action Severity INFO FW-1304 Message , [FW-1304], ,, INFO, , , value has changed(High=, Low - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 320
internet protocol (IP) addresses that are authorized to establish API connections to switches in the fabric. Recommended No action is required. Action Severity INFO FW-1308 Message , [FW-1308], ,, INFO, , , value has changed(High=, Low - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 321
is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the number of simple network management protocol read (RSNMP) violations has changed from a value outside of the acceptable range to a value within the acceptable - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 322
-name>, , is above high boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of simple network management protocol write (WSNMP) violations has risen above the high boundary. WSNMP violations indicate that an SNMP "get/set - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 323
>, Low=). Current value is . Probable Cause Indicates that the number of SES violations has changed. SES violations indicate that a small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world wide name (WWN). The - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 324
value>). Current value is . Probable Cause Indicates that the number of SES violations has risen above the high boundary. SES violations indicate that a small computer system interface (SCSI) Enclosure Services (SES) request has been received from an unauthorized world wide name (WWN - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 325
>, is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the number of simple network management server (MS) violations has changed from a value outside of the acceptable range to a value within the acceptable range - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 326
Current value is . Probable Cause Indicates that the number of serial violations has risen above the high boundary. Serial violations indicate port request has been received. The SERIAL_POLICY contains a list of switch world wide names (WWNs) for which serial port access is enabled - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 327
value>). Current value is . Probable Cause Indicates that the number of serial violations has changed from a value outside of the acceptable range port request has been received. The SERIAL_POLICY contains a list of switch world wide names (WWNs) for which serial port access is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 328
value is . Probable Cause Indicates that the number of switch connection control policy (SCC) violations has changed. SCC violations indicate that an unauthorized switch tried to join the fabric. The SCC_POLICY contains a list of switches by world wide name (WWN) that are allowed to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 329
between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the number of switch connection control policy (SCC) violations has changed from a value outside of the acceptable range to a value within the acceptable range. SCC - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 330
WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity INFO FW-1337 Message , [FW-1337], ,, INFO, , , is below low boundary(High= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 331
, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING FW-1339 Message , [FW-1339], ,, INFO, , , is between high and low boundaries - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 332
Current value is . Probable Cause Indicates that the number of login violations has risen above the high boundary. Login violations indicate a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 333
switch compares this timestamp to its current time. If the difference is too great, it rejects the packet. This counter keeps track of packets rejected due to invalid timestamps. Recommended No action is required. Action Severity INFO FW-1346 Message , [FW-1346], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 334
has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid signatures. Recommended No action is required. Action Severity INFO FW-1350 Message , [FW - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 335
has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid signatures. Recommended No action is required. Action Severity INFO FW-1352 Message , [FW - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 336
and its certificate is signed by the Root CA recognized by the receiving switch. This counter keeps track of the number of packets received with invalid certificates. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 337
value>). Current value is . Probable Cause Indicates that the number of authentication failures has changed. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly, or send - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 338
>. Probable Cause Indicates that the number of authentication failures has changed from a value outside of the acceptable range to a value within the acceptable range. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 339
value is . Probable Cause Indicates that the number of switch link authentication protocol (SLAP) faulty packets has changed from a value is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed. Recommended Responses to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 340
value>). Current value is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed from a value outside of the fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 341
is . Probable Cause Indicates that the number of no-FCS violations has fallen below the low boundary. This counter records how often the switch loses contact with the primary fabric configuration server (FCS) switch. When the primary FCS switch in the fabric sends its certificate to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 342
violations has fallen below the low boundary. This violation indicates the number of secure switches with different version stamps have been detected. When a switch is in secure mode, it connects only to another switch that is in secure mode and has a compatible security database. A compatible - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 343
violations has risen above the high boundary. This violation indicates the number of secure switches with different version stamps have been detected. When a switch is in secure mode, it connects only to another switch that is in secure mode and has a compatible security database. A compatible - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 344
counter increments every time someone issues one of these commands on a switch where it is not allowed. Recommended No action is required. Action Severity INFO FW-1378 Message , [FW-1378], ,, WARNING, , , is above high boundary(High= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 345
. Action Severity INFO FW-1400 Message , [FW-1400], ,, INFO, , , value has changed(High=, slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action is required. - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 346
slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action is required. number>,, WARNING, , Switch status change contributing factor Power supply: bad, absent. Indicates that the switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 347
. Action Severity WARNING FW-1428 Message , [FW-1428], ,, WARNING, , Switch status change contributing factor Power supply: absent. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 348
the switchStatusPolicySet command. Recommended Replace the faulty WWN card. Action Severity WARNING FW-1433 Message , [FW-1433], ,, WARNING, , Switch status change contributing factor CP: CP non-redundant. 290 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 349
was up on a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to clear the problem. Severity WARNING FW-1434 Message , [FW-1434], ,, WARNING, , Switch status change contributing factor Blade: blade failures - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 350
faulty or deteriorating small form-factor pluggables (SFPs). Action Severity WARNING FW-1438 Message , [FW-1438], ,, WARNING, , Switch status change contributing factor Missing SFPs: missing SFPs. Probable Cause Indicates that the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 351
has changed to "inserted". This means that an FRU is inserted but not powered on. Recommended No action is required. Verify that the event was planned. Action Severity INFO FW-1442 Message , [FW-1442], ,, INFO, , state has changed to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 352
switch now requires 4 power supplies for full (2X) redundancy, but the user has previously overridden the Switch Status Policy values pertaining to number of power supplies. So those values will not be automatically changed. The default values with no AP blades are: 3 out of service indicates switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 353
Severity WARNING FW-1501 Message , [FW-1501], ,, INFO, , Mail overflow cleared - occur due to software glitches. Persistent errors occur due to hardware problems. Recommended Check for concurrent loss of synchronization errors. Check the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 354
35 FW-1510 296 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 355
blade by ejecting the card and reseating it. If the problem persists, replace the standby CP. Severity CRITICAL HAM-1002 Message , [HAM-1002], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 356
it if it is down. Recommended No action is required. Action Severity INFO HAM-1006 Message Probable Cause , [HAM-1006], ,, CRITICAL, ,EMAC controller for Active CP is BAD. Indicates that the local EMAC controller on the active control processor (CP) is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 357
is enabled. Recommended No action is required. Action Severity CRITICAL HAM-1009 Message , [HAM-1009], ,, CRITICAL, ,Need to MANUALLY REBOOT the system for recovery - auto-reboot is disabled. Probable Cause Recovery by reboot is disabled, the system - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 358
36 HAM-1009 300 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 359
and contact your switch service provider. Severity CRITICAL HAMK-1002 Message , [HAMK-1002], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 360
37 HAMK-1004 HAMK-1004 Message ,[HAMK-1004], ,, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 361
is below the threshold. Recommended Replace the faulty blade or switch (for nonbladed switches). Action Severity ERROR HIL-1103 Message , [HIL-1103], ,, ERROR, , Blower faulted, () is above threshold - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 362
FRU to verify that they are seated properly. If the problem persists, replace the fan FRU or the power supply FRU as necessary. Severity ERROR HIL-1105 Message , [HIL-1105], ,, ERROR, , Switch error, () above threshold - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 363
motherboard FRU. For the Brocade 4100, 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other voltage is faulty, replace the entire switch. Severity ERROR HIL-1108 Message , [HIL-1108], , FFDC, CRITICAL, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 364
-name>, Fan faulted, speed ( RPM) below threshold. Probable Cause Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. This message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000. Recommended - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 365
number> , speed ( RPM) below threshold. Probable Cause Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 366
message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Replace the affected fan FRU immediately. Action Severity ERROR HIL-1304 Message , [HIL-1304], ,, ERROR, , Two fans failed. Replace failed - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 367
low fan speed message. Recommended Replace the faulty fan FRUs immediately. Action Severity ERROR HIL-1307 Message , [HIL-1307], ,, ERROR, , Four or five fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 368
fan speed message. Recommended Since the fans are not field replaceable, replace the switch if the temperature is high. Action Severity WARNING HIL-1311 Message , [HIL-1311], ,, INFO, , No fans are faulty. Probable Cause Indicates recovery from earlier - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 369
WARNING HIL-1501 Message Probable Cause , [HIL-1501], ,, WARNING, , Slot , high temperature (). Indicates that the temperature of this blade has risen above the warning threshold. Fabric OS Message Reference 311 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 370
is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the blade. Severity CRITICAL HIL-1503 Message , [HIL-1503], , FFDC, CRITICAL, , Slot - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 371
switch. Refer to the hardware reference manual for your switch for the operational temperature range. Severity CRITICAL HIL-1507 Message , [HIL-1507], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 372
switch. Refer to the hardware reference manual for your switch for the operational temperature range. Severity CRITICAL HIL-1509 Message , [HIL-1509], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 373
not supplying power, fan speeds not available. Please ensure that the unit has power and the switch is on. Indicates that the power supply is not connected to a power source or it is not switched on or the unit is faulty. Applicable only to Brocade 5100. Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 374
is connected to the unit with a valid power source and then switch on the Action unit. If the problem persists, try reseating the unit. If the problem still persists replace the FRU. Severity WARNING HIL-1650 Message , [HIL-1650], , ERROR, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 375
Hello timeout from port , correct value . Probable Cause Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The Brocade switch will not accept FSPF frames from the remote switch. In the Fabric OS, the HLO timeout - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 376
an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended The HLO message of the remote switch must be compatible with the value specified in the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 377
sequence-number>, FFDC, CRITICAL, , Probable Cause Indicates there was a problem reading firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 378
40 HMON-1001 320 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 379
1001 Message , [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . refer to the Fabric OS Administrator's Action Guide. Severity INFO HTTP-1002 Message , [HTTP-1002], , AUDIT, INFO, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 380
41 HTTP-1003 322 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 381
ERROR, , Slot , Port GE: Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Power off and power on the blade using the slotPowerOff and - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 382
42 IBD-1001 324 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 383
WARNING, , iSCSI login sessions exceed the maximum limit at slot port ge Probable Cause Indicates that the iSCSI login sessions exceed the supported limit per port. Recommended Use another port to log in. Action Severity WARNING Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 384
43 IBPD-1003 326 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 385
or power cycle the switch. Severity ERROR ICPD-1002 Message , [ICPD-1002], ,, ERROR, , Failed to initialize rc = . Probable Cause Indicates that an initialization of a module within the ICPD failed. Recommended Download a new firmware - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 386
. Severity WARNING ICPD-1006 Message , [ICPD-1006], ,, INFO, , iSCSI service is on the switch. Probable Cause Indicates the iSCSI service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO ICPD-1007 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 387
Recommended No action is required. Action Severity INFO 44 ICPD-1008 Fabric OS Message Reference 329 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 388
44 ICPD-1008 330 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 389
of managed entity> . Probable Cause Indicates that a change in the gateway IP address has occurred. If the source of the address change is manual, this means that the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 390
45 IPAD-1001 332 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 391
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING IPS-1004 Message , [IPS-1004], ,, WARNING, , Port Config Mode Mismatch slot () port(ge): current mode is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 392
>,, WARNING, , Tunnel Authorization Failure for slot () port(ge) tunnel ID() reason () Probable Cause Indicates that tunnel setup failed because of an authorization failure from the remote side. A reason for such a failure could be a WWN - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 393
Chapter ISCS System Messages 47 ISCS-1000 Message , [ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates the specified port has crashed. Recommended No action is required; the port will restart - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 394
47 ISCS-1000 336 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 395
Start peering with external iSNS server slot/port /ge. Probable Cause Indicates that peering has started with the specified external internet storage name service (iSNS) server. Recommended No action is required. Action Severity INFO ISNS-1003 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 396
re-register with external iSNS server slot/port /ge. Probable Cause Indicates that the re-register with the specified external internet storage name service (iSNS) server has started. Recommended No action is required. Action Severity INFO ISNS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 397
with a valid slot/port. Refer to the appropriate hardware reference manual for valid slot and Action port ranges. Severity WARNING ISNS-1011 Message , [ISNS-1011], ,, INFO, , iSNS Client Service is . Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 398
48 ISNS-1014 Probable Cause Indicates that the internet storage name service (iSNS) client failed to establish a connection with IP address. Severity WARNING ISNS-1014 Message , [ISNS-1014], ,, INFO, , Start peering with external iSNS server - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 399
the configured key value is operational, and if it is not, change the switch key Action vault settings. Severity ERROR KAC-1006 Message , [KAC-1006], ,, ERROR, , Switch to key vault trustee link was not established. Probable Cause Indicates that the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 400
Determine whether the configured key value is operational, and if it is not, change the switch key Action vault settings. Severity ERROR KAC-1008 Message , [KAC-1008], ,, ERROR, , Putting TEP failed check if there is already an unapproved TEP then - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 401
Copy the warning message along with any core file information, and contact your switch service Action provider. Severity WARNING KSWD-1002 Message , [KSWD-1002], , FFDC, WARNING, , Detected termination of process : - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 402
found, run supportFtp to send all core files to a secure server location. Copy the warning message along with any core file information, and contact your switch service provider. Severity WARNING 344 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 403
is not initialized properly. Recommended No action is required. Action Severity ERROR KTRC-1004 Message Probable Cause , [KTRC-1004], ,, ERROR, , Cannot write to ATA dump device Indicates the write boundry in the ATA dump device has exceeded. Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 404
51 KTRC-1005 Recommended No action is required. Action Severity ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that a trace was unable to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 405
,, INFO, , The Logical Fabric Manager configuration is set to default. Probable Cause Indicates that the Logical Fabric Manager configuration is set to default. This will remove all prior Logical Fabric Manager configurations. This operation is not supported, currently - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 406
ffdc log to the support. Action Severity CRITICAL LFM-1005 Message , [LFM-1005], ,, WARNING, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 407
switches or the haFailover command on bladed switches. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING LOG-1002 Message , [LOG-1002], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 408
53 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates the persistent error log has been cleared. Recommended No action is required. Action Severity INFO 350 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 409
valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended No action is required. Action Severity ERROR LSDB-1002 Message , [LSDB-1002], ,, INFO, , Local Link State Record reached max - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 410
-1004 Message , [LSDB-1004], ,, WARNING, , No Link State Record for domain Probable Cause Indicates there is no link state record for the specified local domain. Recommended No action is required. The other switch will pass the LSD once the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 411
; then run the supportSave command and contact your switch service provider. Severity ERROR MFIC-1002 Message , [MFIC-1002], ,, INFO, , Chassis FRU header not programmed for switch NID, using defaults (applies only to FICON environments). Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 412
. IDID mode can be set using the configure command in the CLI or checking the Advanced Web Tools Switch Admin > Configure Tab > Fabric Subtab > Insistent Domain ID Mode check box. The switch must be disabled to change the IDID mode. Severity WARNING 354 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 413
Indicates a link state record is null. Recommended No action is required. Action Severity ERROR MPTH-1003 Message , [MPTH-1003], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates the FSPF module has determined that there is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 414
56 MPTH-1003 356 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 415
57 MQ-1004 Message , [MQ-1004], ,, ERROR, , mqRead, queue = - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 416
57 MQ-1004 358 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 417
Cause Indicates the management server (MS) has segmented from another switch domain at the specified port number because of errors or inconsistencies defined in the MS platform service. Recommended Reboot or power cycle the switch. Action Severity WARNING MS-1002 Message , [MS-1002 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 418
) by> Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, and and contact your switch service provider. Severity INFO MS-1004 Message , [MS-1004], ,, INFO, < - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 419
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MS-1008 Message , [MS-1008], ,, ERROR, , MS Failure while initializing Probable Cause Indicates the management server - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 420
Action Persistent RLIR incidents are likely the result of SAN hardware problems such as bad cables or small form-factor pluggables switch service provider. Severity ERROR MS-1022 Message , [MS-1022], ,, INFO, , Management Server Platform Service - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 421
58 MS-1023 MS-1023 Message , [MS-1023], ,, INFO, , Management Server Topology Discovery Service . Probable Cause Indicates Management Server Topology Discovery Service is being enabled or disabled. Recommended No action is required. - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 422
58 MS-1024 364 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 423
() Probable Cause Indicates a duplicate E_Port State Change Number was reported. The neighbor finite state • 5 - Full If this error occurs repeatedly, then there is a problem in the protocol implementation between two switches. Recommended Action Run - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 424
NBFS-1003 Message , [NBFS-1003], ,, WARNING, , DB_XMIT_SET flag not set Wait • 4 - Database Wait • 5 - Full Recommended No action is required. The Fabric OS automatically recovers from this problem. Action Severity WARNING 366 Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 425
-number>,, WARNING, , Remote switch 0x has firmware revision lower than 2.2: which is not supported! Probable Cause Indicates the local switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 426
of the lowest version of firmware. Severity INFO NS-1005 Message , [NS-1005], ,, WARNING, , Zone size of has over the supporting limit of for the remote switch domain ID . Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 427
to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1002 Message , [PDM-1002], ,, WARNING, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 428
to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1006 Message , [PDM-1006], ,, WARNING, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 429
to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1008 Message , [PDM-1008], ,, WARNING, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 430
to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1012 Message , [PDM-1012], ,, WARNING, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 431
to reinstall the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1017 Message , [PDM-1017], , FFDC, CRITICAL, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 432
switch service provider. Severity WARNING PDM-1022 Message , [PDM-1022], ,, WARNING, , The switch is configured only with IPv6. Probable Cause Indicates the parity data manager (PDM) cannot synchronize with its peer because the firmware does not support - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 433
61 PDM-1024 Fabric OS Message Reference 375 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 434
61 PDM-1024 376 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 435
Run the pdShow command to view the panic dump and core dump files. Action Severity INFO PDTR-1002 Message , [PDTR-1002], ,, INFO, , . Probable Cause Indicates information has been written to the panic dump and core dump files and - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 436
62 PDTR-1002 378 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 437
the supportSave command and contact your switch service provider. Severity CRITICAL PLAT-1001 Message , [PLAT-1001], ,, INFO, , CP does not solve the problem. If Action the problem still persists, then replace the CP. Fabric OS Message Reference 379 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 438
63 PLAT-1003 Severity CRITICAL PLAT-1003 Message , [PLAT-1003], , FFDC, CRITICAL, , Slot C/BE: ADBUS: misc_intr . Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 439
Chapter PMGR System Messages 64 PMGR-1001 Message , [PMGR-1001], , INFO, , Switch was successfully created. Probable Cause Indicates the switch with the specified FID was successfully created. Recommended No action is required. Action Severity - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 440
64 PMGR-1005 Recommended No action is required. Action Severity WARNING PMGR-1005 Message , [PMGR-1005], , INFO, , Ports on slot to switch were moved successfully. Probable Cause Indicates the successful attempt to move the ports to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 441
64 PMGR-1009 Recommended No action is required. Action Severity WARNING PMGR-1009 Message , [PMGR-1009], , INFO, , The base switch was successfully changed to switch . Probable Cause Indicates the successful change of the base switch. Recommended - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 442
64 PMGR-1010 384 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 443
This problem is typically related to hardware. Recommended Action Check and replace (if necessary) the hardware attached to both ends of the specified port number, -1005], ,, WARNING, , Slot port does not support configured L_port. Issue - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 444
65 PORT-1005 Recommended Invoke the portCfgLport to clear the L_port configuration. Action Severity WARNING 386 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 445
or power cycle the switch to Action reinitiate the firmware. Severity CRITICAL PS-1001 Message , [PS-1001], ,, INFO 's Guide for more information about the Action PID format. Severity INFO PS-1002 Message , [PS-1002], ,, INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 446
, [PS-1004], ,, WARNING, , Failed to End-to-end monitoring is not supported on ISL ports when ISL monitoring is switch. Probable Cause Indicates that end-to-end monitors are configured on the switch. Recommended Delete end-to-end monitors on that switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 447
enabled. Probable Cause Indicates the portSwap feature has been enabled in the switch. Recommended No action is required. Action Severity INFO PSWP-1003 Message , [PSWP-1003], ,, INFO, , Port Swap feature disabled. Probable Cause Indicates the portSwap - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 448
67 PSWP-1003 390 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 449
) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity INFO RAS-1002 Message , [RAS-1002], ,, WARNING, , First failure data capture (FFDC) maximum storage size ( MB - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 450
internal software error. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1006 Message , [RAS-1006], , INFO, , Support data file () automatically transferred to remote address - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 451
that the USB storage device is enabled. Recommended No action is required. Action Severity INFO RAS-3003 Message , [RAS-3003], , WARNING, , USB storage device was unplugged before it was disabled. Probable Cause Indicates that the USB storage device was - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 452
68 RAS-3004 Recommended No action is required. Action Severity INFO 394 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 453
to upgrade the firmware for any switches that do not support RCS. Severity INFO RCS-1002 Message , [RCS-1002], ,, INFO, command. Check memory usage on the switch using the memShow command. Reboot or power cycle the switch. Severity ERROR Fabric OS Message Reference - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 454
greater, and v4.1 and greater. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message , [RCS-1005], ,, INFO, , Phase , Application returned - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 455
69 RCS-1007 Severity INFO RCS-1007 Message , [RCS-1007], ,, ERROR, , Zone DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 456
69 RCS-1008 398 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 457
type (First time encryption/Rekey/Write Metadata)> operation.\n.\n No response from cluster member WWN: Slot: . Probable Cause Indicates that a First time encryption/re-key/Write Metadata was not started. Recommended Correct the Cluster Ethernet link error - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 458
70 RKD-1003 400 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 459
and password from the Fabric Access API host. Action Severity WARNING RPCD-1002 Message , [RPCD-1002], ,, WARNING valid SSL certificate on the switch. Action Severity WARNING RPCD-1003 Message , [RPCD-1003], ,, WARNING, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 460
has been corrupted. Recommended To enable RPCD in Secure mode, install a valid SSL certificate the switch. Action Severity WARNING RPCD-1005 Message , [RPCD-1005], ,, WARNING, , Missing private key file. Secure RPCd is disabled. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 461
timestamp>, [RTWR-1001], ,, ERROR, , timestamp>, [RTWR-1002], ,, WARNING, , the RTWR has exhausted the maximum number of retries sending data to the specified domain ID is online. Enable the switch with the specified domain ID. If the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 462
RTWR-1003 Message , [RTWR-1003], ,, INFO, , : RTWR retry to domain , iu_data the supportSave command and contact your switch service provider. Severity INFO 404 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 463
Chapter SAS System Messages 73 SAS-1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st= rsn= - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 464
73 SAS-1001 406 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 465
-number specified daemon name is full. This might be caused complete listing, see the Introduction to this manual. • fabricd • asd • evmd • switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 466
74 SCN-1001 408 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 467
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1002 Message , [SEC-1002], ,, ERROR, , Security data fails: . Probable Cause Indicates that the receiving - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 468
, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING SEC-1005 Message , [SEC-1005], ,, INFO, , Primary FCS receives data request from domain - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 469
host is displayed in the message. Recommended Check for unauthorized access to the switch through the HTTP connection. Action Severity INFO SEC-1009 Message , [SEC-1009], ,, INFO, , Security violation: Unauthorized host with IP address - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 470
access to the switch through the SSH connection. Action Severity INFO SEC-1022 Message , [SEC-1022], ,, WARNING, < for re-creating PKI objects, outlined in the Secure Fabric OS Administrator's Guide. If a certificate does not exist or is invalid, install the certificate - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 471
is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1028 Message , [SEC-1028], ,, ERROR, , No name is specified. Probable Cause Indicates a corruption occurred during the distribution of the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 472
error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1031 Message , [SEC-1031], ,, WARNING, , Current security policy DB cannot be supported by standby. CPs will go out of sync. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 473
supports use of the asterisk for adding switches to policies. Recommended Action Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to add specific switches to the switch , [SEC-1036], ,, ERROR, , Device name - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 474
format. Recommended Run the command again using the standard WWN format, 16 hexadecimal digits grouped as eight Action colon separated pairs. For example Severity ERROR SEC-1038 Message , [SEC-1038], ,, ERROR, , Invalid domain . Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 475
Severity ERROR SEC-1044 Message , [SEC-1044], ,, ERROR, , Duplicate member in ( - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 476
error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1049 Message , [SEC-1049], ,, ERROR, , Invalid switch name . Probable Cause Indicates there has been a corruption during the distribution - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 477
is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1052 Message , [SEC-1052], ,, ERROR, , Invalid input. Probable Cause Indicates there has been a corruption during the distribution of the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 478
in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1055 Message , [SEC-1055], ,, ERROR, , Invalid FCS list Probable Cause Indicates there has been a corruption during the distribution - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 479
the switch and remove them from the flash. Action Severity ERROR SEC-1062 Message , [SEC-1062], ,, ERROR, , Invalid number of Domains in Domain List. Probable Cause Indicates that either no domains or domains more than the maximum number supported are - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 480
needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1071 Message , [SEC-1071], ,, ERROR, , No new security policy data to apply. Probable Cause Indicates that no - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 481
) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1073 Message , [SEC-1073], ,, ERROR, , No FCS policy in list! Probable Cause Indicates the specific policy type - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 482
for the change to take effect. Action Severity ERROR SEC-1077 Message , [SEC-1077], ,, ERROR, , Failed to activate new policy set on all switches. Probable Cause Indicates the policy could not be activated. Possible reasons that the policy could not be - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 483
is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1081 Message , [SEC-1081], ,, ERROR, , Entered a name for a DCC policy ID that was not unique. Probable Cause Indicates the device connection - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 484
is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1084 Message , [SEC-1084], ,, ERROR, , Name exists for different type . Probable Cause Indicates the specified policy already - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 485
limit> bytes. Probable Cause Indicates the security database has more data than can be distributed to some of the switches in the fabric. Recommended Reduce the number of entries in the security policies to decrease the security database size. Action Severity ERROR SEC-1088 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 486
is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1091 Message , [SEC-1091], ,, ERROR, , No policy to remove. Probable Cause Indicates the specified policy member does not exist or the policy - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 487
is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1095 Message , [SEC-1095], ,, ERROR, , Deleting FCS policy is not allowed. Probable Cause Indicates there has been a corruption during the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 488
to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR SEC-1098 Message , [SEC-1098], ,, ERROR, , No FCS list. Probable Cause Indicates the specified policy - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 489
security database to the other switches in the fabric and local all switches in the fabric are in the ready state. When all switches are number>,, ERROR, , Fail to download . Probable Cause Indicates the switch Action Verify the primary switch has a valid certificate - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 490
the Action command when all switches are READY. Severity ERROR SEC-1106 Message , [SEC-1106], ,, ERROR, , the Secure Fabric OS Administrator's Guide. Severity ERROR SEC-1107 Message , [SEC-1107], ,, INFO, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 491
in the fabric are in the ready state. When all switches are in the ready state, retry the operation. Severity ERROR SEC-1110 Message , [SEC-1110], ,, ERROR, , FCS list must be the first entry in the [Defined Security policies] section. Fail to download - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 492
Make sure that the new FCS policy is the same as the current FCS policy on the switch. Action Severity ERROR SEC-1113 Message , [SEC-1113], ,, WARNING, , [ license ] going to expire in days. Probable Cause Indicates the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 493
, [SEC-1117], ,, INFO, , Fail to set . Probable Cause Indicates the switch failed to save the data received by the primary fabric configuration server (FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 494
, retry the operation. Severity ERROR SEC-1122 Message , [SEC-1122], ,, INFO, , Error code: , . Probable Cause Indicates that one of the switches in the fabric could not communicate with the primary fabric configuration server - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 495
by your enterprise security policy. Severity INFO SEC-1130 Message , [SEC-1130], ,, INFO, , The Primary FCS has failed over to a new switch. Probable Cause Indicates an FCS failover operation was completed successfully. Recommended Action Verify the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 496
secure fabric. Severity ERROR SEC-1137 Message , [SEC-1137], ,, ERROR, , No signature in . Probable Cause Indicates the receiving switch fails to validate the security database sent from the primary fabric configurations - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 497
switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service [SEC-1145], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 498
support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 499
automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO SEC-1158 Message , [SEC-1158], ,, INFO, , Invalid name . Probable Cause Indicates the specified name is invalid. The - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 500
is in the error state, the database might not be correctly updated for that specific switch. Severity INFO SEC-1160 Message , [SEC-1160], ,, INFO, , Duplicate port in port list (). Probable Cause Indicates a duplicate port member - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 501
is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1167 Message , [SEC-1167], ,, ERROR, , Another FCS failover is in process. Command terminated. Probable Cause Indicates that because another - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 502
a license if you do not have one. Severity ERROR SEC-1172 Message Probable Cause , [SEC-1172], ,, ERROR, , Failed to identify role. Indicates the switch is unable to determine its role (primary FCS or backup FCS) in the secure fabric. 444 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 503
Severity ERROR SEC-1174 Message , [SEC-1174], ,, ERROR, , Failed to set password. Probable Cause Indicates the FCS or non-FCS password could not be set. Recommended Verify all switches in the fabric are in time synchronization with the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 504
switches in the fabric are in time synchronization with the primary and that no external Action entity is trying to access the fabric. When verification is complete, retry the operation. Severity ERROR SEC-1180 Message , [SEC-1180], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 505
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1184 Message , [SEC-1184], ,, INFO, , configuration change, action , server ID . Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 506
>,, INFO, , Security violation: Unauthorized device tries to FLOGI to index/area of switch . Probable Cause Indicates a device connection control (DCC) security violation was reported. The specified device attempted to login using fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 507
to log in through a serial or modem connection; the login failed. Recommended Use the correct password. Action Severity INFO SEC-1193 Message , [SEC-1193], ,, INFO, , Security violation: Login failure attempt via . IP Addr: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 508
might not be correctly updated for that specific switch. Severity WARNING SEC-1196 Message , [SEC-1196], ,, WARNING, , Switch does not have all default account names. Probable Cause Indicates the default switch accounts admin and user do not exist on - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 509
security policy. Severity INFO SEC-1199 Message , [SEC-1199], ,, INFO, , Security violation: Unauthorized access to serial port of switch . Probable Cause Indicates a serial connection policy security violation was reported. An - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 510
command was forwarded from a non-primary fabric configuration server (FCS) switch. Recommended Action Check the MS policy and verify that the connection is 1201], ,, INFO, , Security violation: MS device operates on non-primary FCS switch. Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 511
FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1300 Message , [SEC-1300], ,, INFO, , This switch is in VcEncode mode. Security is not supported. Fabric OS Message Reference 453 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 512
SEC-1302 Message , [SEC-1302], ,, INFO, , This switch does not have all the required PKI objects correctly update the firmware to the latest version for your specific Action switch. Verify the firmware you are installing supports the Brocade Secure Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 513
for that specific switch. Severity INFO SEC-1305 Message , [SEC-1305], ,, INFO, , This switch has no outlined in the Secure Fabric OS Administrator's Guide. If PKI objects are valid, verify that an unauthorized switch is not trying to access the fabric - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 514
Message , [SEC-1308], ,, INFO, , All %s servers have failed to respond. Probable Cause Indicates that all servers in the remote authentication dial-in user service (RADIUS) configuration have failed to respond to a switch request within the specified time - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 515
the fabric to set the password policies to the default value. Then verify with passwdCfg --show that password policies are set to the default values on all switches and retry the secModeEnable command. Severity ERROR SEC-1312 Message , [SEC-1312], ,, INFO, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 516
address failed. Recommended Reboot the system to fix this error. If the problem persists contact your switch service provider. Action Severity ERROR SEC-1315 Message , [SEC-1315], ,, ERROR, , command failed - - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 517
number>,, WARNING, , Non-acl domain tries to join a fabric with strict fabric wide policy Probable Cause Indicates that a domain not supporting the security enable failed on the fabric because the switch has a conflicting configuration such as fabric wide consistency - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 518
Message , [SEC-1322], ,, WARNING, , Some DCC policy is too large, distribution cancelled Probable Cause Indicates this fabric is not able to support a device connection control (DCC) policy with more than 256 ports. Recommended Reconfigure any policy that - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 519
wide name (WWN) to the SCC policy, then attempt to join the switch with the fabric. Severity ERROR SEC-1326 Message , [SEC-1326], ,, INFO, , Event: fddcfg --fabwideset, Status: success, Info: Fabric wide configuration set to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 520
to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1330 Message , [SEC-1330], ,, ERROR, , command failed - db - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 521
mode for FCS as Strict. Severity ERROR SEC-1333 Message , [SEC-1333], ,, ERROR, , command failed. There are VF enabled switches in fabric. db(s) distribution is blocked. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 522
is displayed in the message. Recommended Check for unauthorized access to the switch through the specified protocol connection. Action Severity INFO SEC-3050 Message Probable Cause , [SEC-3050], , AUDIT, INFO, , Event: , Status: success, Info - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 523
event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3051 Message , [SEC-3051], , AUDIT, INFO, , The license key is . Probable Cause Indicates that a license key is added or removed - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 524
75 SEC-3051 466 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 525
management protocol (SNMP) service failed and you will not be able to query the switch through SNMP. Recommended Reboot or power cycle the switch. This will automatically initialize SNMP. Action Severity ERROR SNMP-1003 Message , [SNMP-1003], ,, ERROR, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 526
protocol (SNMP) configuration is incorrect and the SNMP service will not work correctly. Recommended Change the SNMP configuration back to the default. Action Severity ERROR SNMP-1005 Message , [SNMP-1005], , AUDIT, INFO, , SNMP configuration attribute - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 527
76 SNMP-1008 Severity INFO SNMP-1008 Message , [SNMP-1008], ,, INFO, , The last device change happened at: . Probable Cause Indicates the last device change time. Recommended Execute the nsshow to view the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 528
76 SNMP-1008 470 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 529
, [SPC-1002], ,, ERROR, , , Security Processor faulted. bladed system, perform slotpoweroff and slotpoweron commands on the blade to recover the system. For a non-bladed system, perform a fastboot command on the switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 530
action is required. Action Severity INFO SPC-2004 Message , [SPC-2004], ,, ERROR, , , : FPGA firmware download failed: 0x%x. Probable Cause Indicates the FPGA download failed. Recommended No action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 531
77 SPC-2005 SPC-2005 Message , [SPC-2005], ,, INFO, , , : FPGA firmware download success: 0x%x. Probable Cause Indicates the FPGA download was successful. Recommended No action is required. Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 532
. User needs to run initEE and regEE. Action Severity CRITICAL SPC-2010 Message , [SPC-2010], ,, CRITICAL, , , : Crypto subsystem cover is open. Probable Cause Indicates the Crypto subsystem cover is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 533
the missing Master Key to current or alternate Action position. Severity ERROR SPC-3003 Message , [SPC-3003], ,, ERROR, , , : No output KEK for DEK rewrap, DEK: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 534
input DEK format • 32 - DEK could not be unwrapped • 33 - FGPA error upon inject • 73 - Invalid KEK format Recommended Contact technical support. Action Severity ERROR SPC-3006 Message , [SPC-3006], ,, ERROR, , - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 535
For status code 14, complete primary KEK generation; otherwise, contact technical support. Action Severity ERROR SPC-3008 Message , [SPC-3008], ,, INFO, , , : SP crypto got READY notification - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 536
been initialized. Recommended Run initEE and regEE. Action Severity ERROR SPC-3011 Message , [SPC-3011], ,, ERROR, , , : Persistent data storage error: , KEK: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 537
Cause Indicates the Crypto Module internal random number generator failed. Recommended Contact technical support. Action Severity ERROR SPC-3015 Message , [SPC-3015], ,, ERROR, , , : RSA pairwise - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 538
77 SPC-3015 480 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 539
>. Probable Cause Indicates SPM failed to initialize. Recommended Check system resources and reboot switch. Action Severity ERROR SPM-1002 Message , [SPM-1002], ,, WARNING, , Generic SPM Warning: . Probable Cause Depends on reason. Recommended - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 540
Probable Cause User configured. Recommended No action is required. Action Severity INFO SPM-1008 Message Probable Cause , [SPM-1008], ,, INFO, , Deregistered SP Certificate in slot . User configured. 482 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 541
78 SPM-1009 Recommended No action is required. Action Severity INFO SPM-1009 Message , [SPM-1009], ,, ERROR, , Certificate is missing. Probable Cause User configured. Recommended Run cryptocfg --initnode. Action Severity ERROR SPM-1010 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 542
78 SPM-1010 484 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 543
set the FTP or SCP parameters. Action After the problem is corrected, rerun the supportSave command. Severity WARNING SS-1002 Message , [SS-1002], ,, INFO, , supportSave has stored support information to the USB storage device. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 544
SS-1003 SS-1003 Message , [SS-1003], ,, WARNING, , supportSave's operation to USB storage device command to check the USB storage device settings. After the USB problem is Action corrected, rerun the supportSave command. Severity WARNING 486 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 545
Do not fail over or power down the system during firmware upgrade. Allow the firmwareDownload command to continue number>, AUDIT, INFO, , Firmwaredownload command has completed successfully. Probable Cause Indicates the firmwareDownload command has completed successfully and switch firmware - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 546
command for more information. Severity INFO SULB-1006 Message , [SULB-1006], ,, INFO, , Forced failover succeeded. New Active CP is running new firmware. Probable Cause Indicates the previous standby CP has now become the active CP and is running - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 547
80 SULB-1008 SULB-1008 Message , [SULB-1008], ,, INFO, , Standby CP booted successfully with new firmware. Probable Cause Indicates the standby CP has rebooted successfully. Recommended Action No action is required. The firmwareDownload command is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 548
secondary partition. Please use firmwareDownloadStatus and firmwareShow to see firmware status." "firmwareDownload has started on Standby CP. up." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareDownload has completed successfully on Standby CP." - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 549
be started to recover the 0xa2 blade." "Blade rebooted during firmwareCommit. The operation will be restarted." 0xa3 "Firmware has been downloaded successfully. Blade is rebooting with the new firmware." 0xa4 "Blade has rebooted successfully." 0xa5 "New firmware failed to boot up. Please retry - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 550
Switch reboots during relocating the AP image. The operation will be restarted." 0xab "Blade Check whether the switch is supported by the requested firmware. Also check service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to create firmware - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 551
Device Based Routing policy is not supported by 5.1. Use aptPolicy to change the routing policy before proceeding." 0x2d "Invalid RPM package. Please reload firmware packages on the file server." 0x2e "Cannot downgrade due to presence of blade type 17. Remove or power off these blades before - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 552
blade type in the chassis. Remove or power off the unsupported blades firmware packages on the file server, then retry firmwareDownload. If the problem director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 553
retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB-1010 Message , [SULB-1010], , AUDIT, INFO, , Firmwarecommit failed (status=0x - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 554
another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message , [SULB-1021],, AUDIT, WARNING, , Firmware is being downloaded to the blade in slot . Probable Cause Indicates the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 555
to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message , [SULB-1024], AUDIT, WARNING, , Firmware commit has completed on the blade in slot . Probable Cause Indicates the firmwareCommit - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 556
progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message Probable Cause , [SULB-1031], , AUDIT, WARNING, , The switch is relocating an internal firmware image. Indicates the switch has rebooted with the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 557
SULB-1033], , AUDIT, WARNING, , Switch has completed relocating the internal firmware image. Probable Cause If the problem persists, contact your switch service provider. Severity ERROR SULB-1035 Message , [SULB-1035], , AUDIT, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 558
be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1036 Message , [SULB-1036], ,, INFO, , . Probable Cause Indicates the firmware version running in the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 559
number>(). Probable Cause Indicates the slot state has been detected as inconsistent during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command. On a Brocade 7500 or AP7600 switch, reboot or power - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 560
ERROR, , Diag attach failed during recovery, disabling slot = . Probable Cause Indicates the Diag blade attach has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command. On - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 561
Action Based on the blade with ports that support port swap. Then port swap the ports back to ports default area. Refer to the Fabric OS Administrator's Guide with switch not in PID format 1. TA enabled ports will be persistently disabled. Probable Cause Indicates the blade is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 562
Probable Cause Indicates the standby control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version on standby that supports Trunk Area functionality, using the Action firmwareDownload command. Severity - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 563
more programs to register with system services or to fail over to active status. Recommended Action The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before rebooting the chassis, record the firmware version on the switch or control processor (CP) and run - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 564
by the system automatically. Recommended Use the supportSave command to gather troubleshooting data. No further action is required. Action Severity INFO SYSC-1005 Message , [SYSC-1005], ,, WARNING, , Daemon is not restarted - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 565
power cycle the switch. Run supportFtp as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL SYSM-1002 Message , [SYSM-1002], ,, INFO, , , Switch: - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 566
and is properly seated in its slot. Action Severity CRITICAL SYSM-1006 Message , [SYSM-1006], , FFDC, CRITICAL, , CP blade in slot is incompatible with the chassis type. Probable Cause Indicates this chassis type is not compatible with the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 567
Chapter TAPE System Messages 84 TAPE-1001 Message , [TAPE-1001], , FFDC, INFO, , Key acquisition for . Probable Cause Indicates that the key acquisition for the pool or the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 568
84 TAPE-1001 510 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 569
• MANUAL generated by the tracedump -n command Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity WARNING TRCE-1002 Message , [TRCE-1002], ,, INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 570
) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR TRCE-1006 Message , [TRCE-1006], ,, INFO, , FTP Connectivity Test succeeded to FTP site ' - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 571
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR TRCE-1010 Message , [TRCE-1010], ,, ERROR, , Traced fails to start Fabric OS Message Reference 513 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 572
your switch service provider. Severity ERROR TRCE-1011 Message , [TRCE-1011], ,, INFO, , Trace dump manually blade is enabled and retry the command. If the AP blade is already enabled, run Action the supportSave command and contact your switch service - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 573
This occurs if the user name or password is entered incorrectly. Recommended Action Normally an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the 1003 Message , [TRCK-1003], ,, INFO, , Logout by user - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 574
the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration Action Severity INFO TRCK-1005 Message , [TRCK-1005], ,, INFO, , Track-changes on. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 575
another. Severity WARNING TS-1002 Message , [TS-1002], ,, INFO, , < Type of clock server used > Clock Server accessible to the switch and functional. If the principal or primary FCS does not support the feature, either choose a different switch for the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 576
number>,, INFO, , . Probable Cause Indicates a time service event is occurring or has failed. The message might be one of the following: • Init failed. Time Service TS-1007], ,, WARNING, , . Probable Cause Indicates a switch is trying to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 577
87 TS-1008 Fabric OS Message Reference 519 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 578
87 TS-1008 520 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 579
Severity INFO UCST-1007 Message , [UCST-1007], , FFDC, CRITICAL, , Inconsistent route detected: Port = , should be Probable Cause Indicates the switch detected an inconsistency in the routing database between the routing - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 580
88 UCST-1025 UCST-1025 Message , [UCST-1025], ,, INFO, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 581
Chapter UPTH System Messages 89 UPTH-1001 Message , [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists in the candidate list ( - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 582
89 UPTH-1001 524 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 583
file is either invalid or absent. Recommended Install a valid key file. Action Severity WARNING WEBD-1002 Message , [WEBD-1002], ,, WARNING, , Missing or Invalid Key file -- HTTPS is configured but could not be started. Probable Cause Indicates the SSL - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 584
Probable Cause Indicates the IP address of the switch changed and the HTTP server is restarted. number>, FFDC, WARNING, , HTTP server cannot be started. Probable Cause Indicates a rare error condition, where the built-in recovery process has failed to restore HTTP services. The problem - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 585
System Messages 91 ZOLB-1001 Message , [ZOLB-1001], ,, ERROR, , ZONELIB Probable Cause Indicates there to save these core files and contact your switch service provider. Severity ERROR Fabric OS Message Reference 527 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 586
91 ZOLB-1001 528 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 587
run the Action supportSave command and contact your switch service provider. Severity WARNING ZONE-1003 Message , [ZONE-1003], ,, WARNING, , zone() contains (, ) which does not exist. Probable Cause Indicates the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 588
overflows (over the S_ID limit), the hardware zone enforcement changes to session-based zoning. Recommended No action is required. Action Severity INFO ZONE-1005 Message , [ZONE-1005], ,, INFO, , HARD & SOFT zones(, ) definitions - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 589
are two ways to avoid this problem. • Avoid having too many hosts zoned with a set of target devices at a single port. • Avoid having too many zones directed at a single port group on the switch. Severity INFO ZONE-1008 Message , [ZONE-1008], ,, WARNING, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 590
>, [ZONE-1013], ,, WARNING, , Quick Loop not supported. Probable Cause Indicates the QuickLoop feature is not supported in the current code release. If the QuickLoop zoning configuration is enabled on the switch, it will not be supported. Recommended Edit the zone - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 591
supported in Fabric OS v4.x and above. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR ZONE-1019 Message , [ZONE-1019], - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 592
up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity INFO ZONE-1024 Message , [ZONE-1024], ,, INFO, , . Probable Cause Indicates the cfgSave command ran successfully - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 593
your fabric. Refer to the Fabric OS Administrator's Guide for information on the zone database sizes supported for each switch. Severity WARNING ZONE-1029 Message Probable Cause Recommended Action , [ZONE-1029], ,, WARNING, , Restoring zone cfg from flash - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 594
command and contact your switch service provider. Severity WARNING ZONE-1030 Message , [ZONE-1030], ,, WARNING, ,, ERROR, , Switch is in interop mode. (switch, port) members not supported. Probable Cause Indicates the switch is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 595
Probable Cause Indicates that a new zone database file was successfully created for the switch. Recommended No action is required. Action Severity WARNING ZONE-1035 Message , [ZONE-1035], ,, ERROR, , Unable to rename to - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 596
the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the Action Severity ERROR ZONE-1038 Message , [ZONE-1038], ,, ERROR, , Unable to allocate memory for - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 597
Action is needed, no action is necessary. Severity INFO ZONE-1043 Message , [ZONE-1043], ,, INFO, , The Default Zone access mode is set to No Access. Probable Cause Indicates the Default Zone access mode is set to No Access. Recommended Verify that this - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 598
,, INFO, , The Default Zone access mode is already set to All Access. Probable Cause Indicates the Default Zone access sequence-number>,, INFO, , Switch domain () does not support defined database. Probable Cause Indicates a remote Brocade switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 599
Cause Indicates that there is an AD-DefZone conflict. Recommended Check and resolve the default zone mismatch issue. Action Severity ERROR ZONE-1050 Message , [ZONE-1050], ,, INFO, , The Interop Safe Zoning mode is set to Enabled. Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 600
ZONE-1053 Message , [ZONE-1053], ,, INFO, , The Default Zone state is set to Disabled. Probable Cause Indicates the Interop Default Zone attribute state is disabled. Recommended Verify if the Interop Default Zone attribute state change was done on purpose - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 601
Audit Log Messages Section II This section provides the Audit messages, including: •AUDIT AG System Messages 545 •AUDIT AUTH System Messages 547 •AUDIT CONF System Messages 551 •AUDIT FCIP System Messages 553 •AUDIT FICU System Messages 555 •AUDIT FW System Messages 557 •AUDIT HTTP System - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 602
- HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 603
Chapter AUDIT AG System Messages 89 AG-1029 Message AUDIT, , [AG-1029], INFO, CFG, , , , F_Port to N_Port mapping has been updated for N_Port . Probable Cause Indicates that the F_Ports mapped to an N_Port have changed and the config - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 604
89 AG-1029 546 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 605
Chapter AUDIT AUTH System Messages 90 AUTH-3001 Message AUDIT, , [AUTH-3001], INFO, SECURITY, , , , Event: , Status: success, Info: type has been changed from [] to []. Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 606
Number> because switch policy is turned off. Probable Cause Indicates that the local switch has rejected the authentication request, because the switch policy is turned off. If the neighboring switch has a strict (ON) switch contact your switch service provider. Severity INFO 548 Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 607
Event: , Status: failed, Info: Port disabled due to receiving an authentication reject with code ' - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 608
90 AUTH-3008 550 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 609
that were downloaded. If admin domain (AD) is enabled, the AD number is specified in the description. Recommended No action is required. Action Severity switch was unsuccessful because there are one or more parameters that require the switch to be disabled. Recommended Disable the switch - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 610
91 CONF-1022 552 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 611
Chapter AUDIT FCIP System Messages 92 FCIP-1002 Message AUDIT, , [FCIP-1002], INFO, CFG, , , , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec/IKE policy was added and the config file was updated. Recommended No action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 612
92 FCIP-1003 554 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 613
Chapter AUDIT FICU System Messages 93 FICU-1011 Message AUDIT, , [FICU-1011], INFO, CFG, , , , FMS mode has been enabled. Probable Cause Indicates the FICON Management server mode has been enabled. Recommended No action is required. Action - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 614
93 FICU-1012 556 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 615
Chapter AUDIT FW System Messages 94 FW-3001 Message AUDIT, , [FW-3001], INFO, , , , Event: , Status: success, Info: Probable Cause Indicates that Port Fencing was enabled/disabled successfully. Recommended No - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 616
94 FW-3001 558 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 617
Chapter AUDIT HTTP System Messages 95 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates that the zoning database has - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 618
95 HTTP-1003 560 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 619
[IPAD-1002], INFO, CFG, , , , Switchname has been successfully changed to . Probable Cause Indicates that a change with the switch name has occured. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 561 53 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 620
96 IPAD-1002 562 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 621
Severity INFO PORT-1008 Message AUDIT, , [PORT-1008], INFO, CFG, , , , GigE Port (ID: ) has been enabled. Probable Cause Indicates a GigE port has been enabled. Recommended No action is required. Action Severity INFO PORT-1009 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 622
97 PORT-1009 Probable Cause Indicates a GigE port has been disabled. Recommended No action is required. Action Severity INFO 564 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 623
server (FCS) failover. • A security policy has been activated. • A security policy has been saved. • A security policy has been aborted. • A non-FCS password has changed. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 624
98 SEC-3004 Recommended Action Verify the new policy creation was planned. If the new policy creation was planned, no action is required. If the new policy creation was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3004 Message AUDIT, < - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 625
98 SEC-3007 Recommended Action Verify the removal of members to the policy was planned. If the removal of members was planned, no action is required. If the removal of members was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3007 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 626
INFO SEC-3012 Message AUDIT, , [SEC-3012], INFO, SECURITY, , , , Event: , Status: success, Info: Temp Passwd on domain [] for account []. Probable Cause Indicates a user has reset the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 627
name> to position . Probable Cause Indicates a user has changed the position of the remote authentication dial-in user service (RADIUS) server. Recommended Action Verify the RADIUS server position was intentionally changed. If the RADIUS server position was intentionally changed - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 628
user has changed the remote authentication dial-in user service (RADIUS) configuration. Recommended Action Verify the RADIUS configuration Info: Passwdcfg parameters set to default values. Probable Cause Indicates the passwdCfg parameters are set to default values. Recommended Action Verify the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 629
. Probable Cause Indicates the maximum number of failed password entries has been exceeded. The account has been locked as a result. Recommended The account may automatically unlock after the lockout duration has expired or an administrator Action may manually unlock the account. Severity INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 630
, , , , Event: , Status: success, Info: User account [] added. Role: [], Password [], Home AD [], AD list []. Probable Cause Indicates a new user account was created - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 631
98 SEC-3028 Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity INFO SEC-3028 Message AUDIT, , [SEC- - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 632
>, Status: success, Info: Distributed db(s) to domains, dom-id(s). Probable Cause Indicates , , Event: , Status: success, Info: Switch is configured to database. Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 633
98 SEC-3035 Severity INFO SEC-3035 Message AUDIT, , [SEC-3035], INFO, SECURITY, , , , Event: ipfilter, Status: success, Info: IP filter policy(ies) saved. Probable Cause Indicates the specified IP filter policies have been - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 634
was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the specified protocol connection. Take Action appropriate action as defined by your enterprise security policy. Severity INFO SEC-3040 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 635
98 SEC-3044 SEC-3044 Message AUDIT, , [SEC-3044], INFO, SECURITY, , , FIPS mode has been changed to . Probable Cause Indicates there was a change in the FIPS mode. Recommended Action Verify the security event was planned. If the - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 636
98 SEC-3048 SEC-3048 Message AUDIT, , [SEC-3048], INFO, SECURITY, , , FIPS mode has been enabled in the system using force option. Probable Cause Indicates the system has been forced to FIPS mode. Recommended Action Verify the security event - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 637
Probable Cause Indicates that the simple network management protocol (SNMP) configuration s incorrect and the SNMP service will not work correctly. Recommended Reset the SNMP configuration to default. Action Severity ERROR SNMP-1005 Message Probable Cause AUDIT, , [SNMP-1005], INFO - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 638
99 SNMP-1006 580 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 639
continue without disruption. Do not fail over or power down the system during firmware upgrade. Run the firmwareDownloadStatus command for more information. Cause Indicates the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 640
failed on Standby CP." "firmwareCommit failed on Standby CP." "firmwareDownload failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to IPC error." "firmwareDownload failed due to IPC error." "Standby - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 641
secondary partition. Please use firmwareDownloadStatus and firmwareShow to see firmware status." "firmwareDownload has started on Standby CP. up." "Standby CP booted up with new firmware." "Standby CP failed to boot up with new firmware." "firmwareDownload has completed successfully on Standby CP." - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 642
be started to recover the 0xa2 blade." "Blade rebooted during firmwareCommit. The operation will be restarted." 0xa3 "Firmware has been downloaded successfully. Blade is rebooting with the new firmware." 0xa4 "Blade has rebooted successfully." 0xa5 "New firmware failed to boot up. Please retry - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 643
Switch reboots during relocating the AP image. The operation will be restarted." 0xab "Blade Check whether the switch is supported by the requested firmware. Also check service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to create firmware - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 644
Device Based Routing policy is not supported by 5.1. Use aptPolicy to change the routing policy before proceeding." 0x2d "Invalid RPM package. Please reload firmware packages on the file server." 0x2e "Cannot downgrade due to presence of blade type 17. Remove or power off these blades before - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 645
blade type in the chassis. Remove or power off the unsupported blades firmware packages on the file server, then retry firmwareDownload. If the problem director-class switch, when firmwareDownload fails, the command will synchronize the firmware on the two partitions of each CP by starting a firmware - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 646
to the blade. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1018 Message Probable Cause AUDIT, , [SULB-1018], ERROR, FIRMWARE, - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 647
If the problem persists, contact your switch service provider. Severity ERROR SULB-1020 Message AUDIT, , [SULB-1020], ERROR, FIRMWARE, , , , New firmware failed to boot in slot . Probable Cause Indicates the BP blade should reboot - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 648
. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message AUDIT, , [SULB-1024], WARNING, FIRMWARE, , , , Firmware commit has completed on the blade in slot . Probable Cause Indicates - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 649
command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message AUDIT, , [SULB-1032], WARNING, FIRMWARE, , , , Relocating an internal firmware image on the CP. Probable Cause - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 650
to be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, , , , HCL failed. Reboot the switch manually using the reboot command. However - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 651
AUDIT SWCH System Messages Chapter 101 SWCH-1012 Message AUDIT, , [SWCH-1012], INFO, CFG, , , , Trunk Area () has been enabled for one or more ports. Probable Cause Indicates a Trunk Area has been enabled for one or more ports and - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 652
101 SWCH-1014 594 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 653
details>, , , In-order delivery option has been enabled. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is required. Action Severity INFO UCST-1022 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 654
>, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is required. Action Severity INFO UCST-1026 Message - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 655
Severity INFO 102 UCST-1027 Fabric OS Message Reference 597 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 656
102 UCST-1027 598 Fabric OS Message Reference 53-1001157-01 - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 657
AUDIT ZONE System Messages Chapter 103 ZONE-3001 Message AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \" - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 658
103 ZONE-3004 The zone object type can be "alias", "zone member", "zone" or "zone configuration". The string "..." appears at the end of the zone object member list if the list was truncated in the message. Recommended Verify the event was planned. If the event was planned, no action is required. - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 659
103 ZONE-3007 ZONE-3007 Message AUDIT, , [ZONE-3007], INFO, ZONE, , , , Event: , Status: success, Info: Zone configuration \"\" enabled. . Probable Cause Indicates the specified zone configuration has been - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 660
103 ZONE-3011 Severity INFO ZONE-3011 Message AUDIT, , [ZONE-3011], INFO, ZONE, , , , Event: , Status: success, Info: Zone object \"\" expunged. Probable Cause Indicates the specified zone object has been expunged - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 661
103 ZONE-3015 An AD object set type is "AD member". The string "..." appears at the end of the AD object member list if the list was truncated in the message. Recommended Verify the event was planned. If the event was planned, no action is required. If the event was not Action planned, take - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 662
103 ZONE-3018 ZONE-3018 Message AUDIT, , [ZONE-3018], INFO, FABRIC, , , , Event: , Status: success, Info: has been deactivated. Probable Cause Indicates the specified admin domain (AD) object has been deactivated. - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 663
103 ZONE-3022 Severity INFO ZONE-3022 Message AUDIT, , [ZONE-3022], INFO, FABRIC, , , , Event: , Status: success, Info: Current AD configuration saved to flash. Probable Cause Indicates the current admin domain (AD) configuration - HP StorageWorks 4/64 | Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 664
103 ZONE-3025 Severity INFO 606 Fabric OS Message Reference 53-1001157-01
53-1001157-01
24 November 2008
Fabric OS
Message Reference
Supporting Fabric OS v6.2.0