- HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 1
53-1001342-01 ® 28 July 2009 Fabric Watch Administrator's Guide Supporting Fabric OS v6.3.0 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 2
any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make brocade.com/support/oscd. Brocade Communications Systems, Incorporated Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 3
2006 OS v5.2.0 features and the FC4-16IP and FC4-48 port blades. Removed references to Brocade 3014 and 3016, as embedded switches are not supported in Fabric OS v5.2.0. Updates to support Fabric OS v5.3.0, implementation of IPV6. June 2007 Fabric Watch Administrator's Guide iii 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 4
to support Fabric OS v6.2.0: Virtual Fabric, port movement, fan monitoring behavior, link reset, DCX-4S. November 2008 Updates to support Fabric OS v6.3.0: portThConfig, portFencing, and sysMonitor commands and Brocade 8000 support. July 2009 iv Fabric Watch Administrator's Guide 53-1001342 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 5
, and warnings xx Key terms xxi Additional information xxi Brocade resources xxi Other industry resources xxi Getting technical help xxii 4 Data values 4 Switch policies 5 Virtual Fabric support 5 Port persistence 5 Port fencing 6 Fabric Watch Administrator's Guide v 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 6
In this chapter 7 Fabric Watch default settings 7 Reasons to customize Fabric 15 Port class areas 15 Resource class area 16 Security class areas 17 SFP class areas 18 bases 21 Time base set to none 21 Time base set to other than none 21 vi Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 7
a threshold 44 Enabling and disabling all port thresholds 45 Changing the threshold boundary level 45 Event configuration 49 Event behavior types 49 Fabric Watch Administrator's Guide vii 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 8
72 Switch Health report 73 Generating a Switch Health report 73 Switch Status Policy report 74 Generating a Switch Status Policy report 74 Port Detail report 75 Generating a Port Detail report 75 Switch and FRU configuration In this chapter 77 viii Fabric Watch Administrator's Guide 53 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 9
FOP_Port class default settings 96 VE_Port class default settings 97 Resource class default settings 98 Security class default settings 98 SFP class default settings 101 portThConfig examples In this appendix 103 portThConfig command shortcuts 103 Fabric Watch Administrator's Guide ix 53 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 10
108 Area Type: LinkFailure 109 Area Type: RX 109 Area Type: TX 109 Area Type: Statechange 109 Area Type: Trunk Utilization 109 x Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 11
Appendix D Index Port fencing types Fabric Watch Administrator's Guide xi 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 12
xii Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 13
Figure 10 Figure 11 Threshold monitoring 27 A buffered data region 27 Time base set to none 28 Event trigger 29 Example without an event 30 Above trigger 32 Configuring Fabric Watch using SNMP 40 Example OID tree 43 Example swFwName screen 44 Fabric Watch Administrator's Guide xiii - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 14
xiv Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 15
Table 15 Table 16 Table 17 Table default settings 53 Advanced Configuration options 65 Numerical values of notification methods 72 Switch status policy monitor health factors 80 Fabric OS commands to view Fabric Watch reports 85 Port detail report columns 90 Fabric Watch Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 16
xvi Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 17
In this chapter •How this document is organized xvii •Supported hardware and software xviii •What's new in this document of accessing each. • Chapter 10, "Switch and FRU configuration" lists the switch status policy factors that affect the health of the switch and describes how to set and view - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 18
• Brocade 5000 • Brocade 5100 • Brocade 5300 • Brocade 5410 • Brocade 5424 • Brocade 5450 • Brocade 5480 • Brocade 7500 • Brocade 7500E • Brocade 7600 • Brocade 7800 • Brocade 8000 • Brocade Encryption Switch • Brocade DCX • Brocade DCX-4S • Brocade 48000 xviii Fabric Watch Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 19
. • Resource class, Flash area. • "F_Port" is now referred to as "FOP_Port." Removed information The following information was removed: • Environment class, fan area (no longer supported). • Performance Monitor, AL_PA area (this area still displays using the fwConfigure command, but it is no longer - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 20
in the narrative portions of this guide are presented in mixed lettercase: for The following notices and statements are used in this manual. They are listed below in order of increasing severity hazardous to you or cause damage to hardware, firmware, software, or data. DANGER A Danger statement - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 21
SANs with Brocade Fabric Switches through: http://www.amazon.com For additional Brocade documentation, visit the Brocade Web site: http://www.brocade.com Release notes are available on the Brocade Connect Web site and are also bundled with the Fabric OS firmware 's Guide xxi 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 22
and messages received • supportSave command output • Detailed description of the problem, including the switch or fabric behavior immediately following the problem, and specific questions • Description of any troubleshooting steps already performed and the results • Serial console and Telnet session - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 23
Document feedback Quality is our first concern at Brocade and we have made every effort to ensure topic needs further development, we want to hear from you. Forward your feedback to: [email protected] Provide the title and version number of the document and as much detail as possible about - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 24
xxiv Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 25
audit messages 4 •Data values 4 •Switch policies 5 •Port persistence 5 •Port of the network hardware. A switch or port failure can prevent data conditions for the device. For example, switches can fail when stored in rooms that are to provide notification before problems arise, such as - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 26
Fabric Watch overview Fabric Watch is an optional storage area network (SAN) health monitor that allows you to enable each switch to constantly monitor its SAN fabric for potential faults and automatically alerts you to problems long before they become costly failures. Fabric Watch tracks a variety - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 27
Fabric Watch forwards event information to a proxy switch, which then forwards the information to a server to notify you. NOTE RAPI Trap is not supported on the following new classes and areas: more detail about each type of event notification. Fabric Watch Administrator's Guide 3 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 28
generated by Fabric Watch, see the Fabric OS Message Reference. For information on configuring an Audit Log, see the Fabric OS Administrator's Guide. Data values A data value represents three aspects of a fabric: a counter value, a measured value, or a state value. Data values are updated by Fabric - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 29
interswitch link (LISL) is the logical portion of the physical connection that joins base switches. You can enable or disable port thresholds and create thresholds for state changes on LISLs, but Fabric Watch does not support other threshold areas such as link loss or signal loss for LISLs as it - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 30
. NOTE Port Fencing is not enabled by default. You must manually enable Port Fencing. Refer to Appendix D, problems, which can be disruptive for the entire switch or fabric. To protect the switch instructions on how to configure port fencing. 6 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 31
Time Base event triggering based on the SAN administrator. • Consolidating multiple messages generated from a single event. Refer to Chapter 6, "Fabric Watch basic configurations," to learn how to configure thresholds, notification, switch status policy, and FRUs. Fabric Watch Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 32
Count • Loss of Sync Count • Packet Loss • Primitive Sequence Protocol Error • Receive (RX) Performance • Step 3: Monitor FRU class areas: • Slot • Power supply • Fan • WWN Refer to Chapter 3, "Fabric Watch components," for a description of all configurable Fabric Watch classes and areas. 8 Fabric - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 33
room temperature is probably incorrectly configured. • If the event setting is continuous, consider switching to triggered. A continuous event setting will cause error messages to be sent repeatedly as messages generated in this situation. Fabric Watch Administrator's Guide 9 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 34
or event log entry in conjunction with Syslog forwarding configured on your switches. RAPI traps and lock port logs are rarely used and it is addition, e-mail notifications are much more resource-consuming on the switch. Post-processing of messages After you have configured thresholds and alerts - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 35
all physical ports on a switch. • Security, which includes temperature and supplied power. In some cases For example, ports connected to another switch can be monitored using both the switch can trigger events based on either of these configurations. Ports that are not connected to another switch - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 36
is made up of the following classes: • E_Port class-Represents ports connected to another switch. Note: If you are using a Brocade 48000 or a Brocade DCX Backbone with an FR4-18i blade, or the Brocade 7500, the E_Port class monitors the following additional ports and creates monitors for each of - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 37
power supplies to be sure that power is always available to a switch. Refers to the ambient temperature inside the switch, in degrees Celsius. Temperature sensors monitor the switch to the switch might occur. NOTE Event Manager (EM) now manages fan monitoring; switch status is calculated based on - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 38
State of a fan has changed. State of a power supply has changed. State of a slot has changed. State of a WWN card has changed. Supported FRU areas depend on the type of Brocade switch. For the following switches, the slot and WWN areas are not supported: • Brocade 300, 4012, 4016, 4018, 4020, 4024 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 39
A loss of signal usually indicates a hardware problem. Note: Loss of signal count still displays using the fwConfigure command, but it is no longer supported. The number of times a synchronization error through a port exceeds the port bandwidth. Fabric Watch Administrator's Guide 15 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 40
software gliches. Persistent errors occur due to hardware problems. Receive (RX) Performance State Changes Note: State changes are supported on LISL ports. Transmit (TX) Performance Utilization it with the configured high threshold value. 16 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 41
reaches a secure switch from an unauthorized IP address. Time Server (TS) which occur when an out-of-synchronization error has been detected. WSNMP violations which occur when an SNMP set operation reaches a secure switch from an unauthorized IP address. Fabric Watch Administrator's Guide 17 53 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 42
9 Area SFP class areas Description Temperature Receive Power (RXP) Transmit Power (TXP) Current Measures the physical temperature of the monitored. For instance, on a 64-port switch, each area of the Port class includes 64 elements. Each element contains information pertaining Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 43
bases 21 •Threshold event settings 23 Threshold values Threshold values are of the following types: • High and low thresholds • Buffer values High and low thresholds High and low threshold values are the values at which potential problems . Fabric Watch Administrator's Guide 19 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 44
met until the data sensed falls below the low threshold value or above the high threshold value. FIGURE 2 A buffered data region 20 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 45
data value - data value one minute ago) against the preset threshold boundary. When you set a time base to a value other than none, there are two main points to remember when configuring events: • The following examples illustrate each point. Fabric Watch Administrator's Guide 21 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 46
data is irrelevant to the example). A high threshold of 2 is specified to trigger an event. A time base of minute is defined. An event occurs only if the rate of change in the specific interval (one minute is well above the high threshold. 22 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 47
to normal operation. The second event will not be triggered until the counter value falls below the high threshold and buffer values. Fabric Watch Administrator's Guide 23 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 48
Fabric Watch detects a change in the counter value between two sample periods (defined by the time base), it triggers an event regardless of high or low threshold settings. Figure 7 shows events generated appropriate for temperature monitoring. 24 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 49
: • IN_RANGE to OUT_OF_RANGE • OUT_OF_RANGE to IN_RANGE No alarm is generated for INFORMATIVE to IN_RANGE (or IN_RANGE to INFORMATIVE) See Chapter 3, "Fabric Watch default settings" for more details about the threshold states for Above, Below, and Changed triggers. Fabric Watch Administrator - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 50
4 Threshold event settings 26 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 51
instructions on how to activate Fabric Watch using Web Tools. • SNMP - Provides a receiver dedicated to monitoring the data center infracture; Brocade switches and directors enable monitoring of specific incidents and trigger an SNMP alert based on a - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 52
license key exactly as it appears. switch:admin> licenseadd "R9cQ9RcbddUAdRAX" 5. Enter the installed. 1. Open the Web browser and type the IP address of the device in the Address field: http username and password. 4. Select a switch from the Fabric Tree and log in if necessary. 5. Select - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 53
the status of fabric elements through SNMP-based enterprise managers. NOTE The following instructions apply to the AdvantNet MIB browser. Web Tools and select Tasks > Manage > Switch Admin. 4. Click Show Advanced Mode. 5. On the SNMP tab, enter the IP address of the trap receiver and the severity - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 54
set the SNMP MIB capability. NOTE Currently, setting the SNMP MIB capability can only be done from the CLI. switch:admin> snmpConfig -set mibcapability The SNMP Mib/Trap Capability has been set to support FE-MIB SW-MIB FA-MIB SW-TRAP FA-TRAP FA-MIB (yes, y, no, n): [yes] FICON-MIB (yes - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 55
t, false, f): [true] . . . Committing configuration...done. sswitch:admin> 8. Enter the IP address for the switch in the Host field in the MIB browser. Enter the community string in the Community field. the temperature sensor will generate traps. Fabric Watch Administrator's Guide 31 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 56
element in which you are interested. For detailed descriptions of the SNMP fields in both Telnet and Web Tools, see the Fabric OS MIB Reference. 32 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 57
or custom settings for monitoring. Use the following commands to switch between default and custom values: • fwSetToCustom Sets the boundary and alarm level to custom. • fwSetToDefault Restores the boundary and alarm level to the default. Fabric Watch Administrator's Guide 33 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 58
meet your particular SAN needs. 1. Connect to the switch and log in as admin. 2. Enter the configUpload command to upload the configuration file to the host. 3. Open one of the profiles that appears on the Brocade Web site at the following location: http://www.brocade.com/support/mibs_rsh/index.jsp - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 59
default configuration settings (the default high and low threshold settings and buffer settings are listed in Appendix B, "Default identify the classes. 1. Connect to the switch and log in as admin. 2. Enter which is the default, exits the fwConfigure menu. NOTE For switches with embedded ports or - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 60
corresponding to the E_Port class displays. switch:admin> fwconfigure 1 : Environment class 7 : Alpa Performance Monitor class (not supported) 8 : EE Performance Monitor class 9 which is always the default, returns you to Sync loss 3 : Signal loss (not supported) 4 : Protocol error 5 : Invalid - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 61
the last event. The last detected state of the element. See Chapter 3, "Fabric Watch components" for more details about classes and areas. Fabric Watch Administrator's Guide 37 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 62
, accept the default configuration settings, which are listed in "Fabric Watch default settings." Configuring packet loss, and state change. 1. Connect to the switch and log in as admin. 2. Enter the portThConfig command to ] 38 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 63
-action_level --show -port_type -area Prints the command usage. Applies the custom or default threshold or alarm configuration. Applies the port type to the specified threshold or alarm LF - Link failure RX - Receive error TX - Transmit error Fabric Watch Administrator's Guide 39 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 64
status. -thresh_level Specifies the threshold level (either default or custom). -action_level Specifies the alarms level (either default or custom). --set Configures the thresholds for PE - Protocol error LR - Link reset ST - State change 40 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 65
switch default or custom). --set Configures the thresholds for monitoring a specified area for all ports of a specified port type. When configuring a threshold, you must specify a port type and an area. port e_port - Configures thresholds for all E_Ports. Fabric Watch Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 66
. Refer to Appendix B, "Default Settings" for the default settings for high and low Refer to Appendix B, "Default Settings" for the default settings for high and to Appendix B, "Default Settings" for the default settings for high and switch reboots, your changes will be lost. 42 Fabric Watch - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 67
option. 1. Type 2 at the Select choice => prompt. The system generates output, which varies based on the class and area you selected. 2. Type the index number of the element for which Fabric 21 14:21:07 2005 0 Percentage(%)/min Informative Fabric Watch Administrator's Guide 43 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 68
The system generates output similar to that in the system output below, but the output you see varies based on the class and area you selected. 2. Type the index number of the element for which Fabric :21:07 2005 0 Percentage(%)/min Informative 44 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 69
upgrade is complete, you can show and enable disabled port thresholds. 1. Use the following command to disable the port threshold. switch such as RX Performance, for which Port Fencing is not supported, you will not be able to set or apply the the output is based on the E_Port 's Guide 45 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 70
boundary level is setat : Default DefaultCustom Unit Percentage(%) Time base minuteminute Low 0 0 High 100 100 BufSize 0 0 Percentage(%) Threshold alarmlevel is set at: Default Errlog-1, SnmpTrap-2, PortLogLock-4 RapiTrap-8, EmailAlert-16, PortFencing-32 Valid alarm matrix is 63 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 71
: change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom is setat : Default DefaultCustom Unit Percentage(%) Time base minuteminute Low 0 : Default 2 : custom Enter boundary level type => : (1..2) [1] 2 Fabric Watch Administrator's Guide 47 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 72
: change custom timebase 15 : change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom high 17 : cancel threshold => : (1..18) [18]9. 5. Type 16 at the Select choice => prompt to apply the changes. 48 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 73
types, threshold values, time bases, and event settings. You cannot change data values; these represent switch behavior that is updated by during every sample period that a port is at full utilization. This information can help you plan network upgrades. Triggered event behavior If you do not want - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 74
sensor set at 80º C. Fabric Watch triggers raslog and SNMP trap alarms in each logical switch based on the configuration. For information on configuring the SNMP agent using the snmpconfig command, see the Fabric OS Command Reference. 50 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 75
switch based on the firmware version. The switch forwards the information to the management server and alerts the SAN manager to event activity. Third-party applications that use the Brocade be forwarded through a relay host. The relay host IP can be configured using the fwMailCfg command. Enabling - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 76
for which Port Fencing is not supported, you will not be able to particular switch to view the error messages that have been captured for that particular switch. following command. switch:admin> have notifications sent. switch:admin> fwAlarmsFilterSet 0 switch:admin> fwalarmsfiltershow FW: Alarms - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 77
PortFencing-32, SnmpTrap-2, and Errlog-1 (32+2+1=35). notification 16 Port fencing 32 To port log lock (8) and e-mail notification (16) methods, but does not allow the SNMP trap alarm 6 : change custom low 16 : apply threshold alarm changes 7 -8, EmailAlert-16 PortFencing - 32 Valid alarm - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 78
base minuteminute Low 0 0 High 100 80 BufSize 0 0 Percentage(%) Threshold alarmlevel is set at: Default Errlog-1, SnmpTrap-2, PortLogLock-4 RapiTrap-8, EmailAlert-16 Triggered 1 BehaviorInt Threshold boundary level is setat : Custom 54 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 79
base minuteminute Low 0 0 High 100 80 BufSize 0 0 Percentage(%) Threshold alarmlevel is set at: Custom . . . 3. Type 16 Set Recipient Mail Address for Email Alert 6 : Relay Host IP Configuration 7 : Quit Select an item => : (1..7) [7] Fabric Watch Administrator's Guide 55 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 80
should disable e-mail alerts. The following confirmation message displays: Email Alert is disabled! The system returns to the main fwMailCfg menu. 56 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 81
Environment class! The e-mail address specified in the mail configuration receives a test e-mail message. The system returns to the main fwMailCfg menu. Fabric Watch Administrator's Guide 57 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 82
for the specific class of alerts. Fabric Watch uses the default value, located between the brackets in the prompt, as the IP: 3. Enter the relay host IP address (example: 192.168.39.118). The following message displays: Setting 192.168.39.118 as Relay Host.. 4. Enter the Domain Name (example: Brocade - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 83
notification 6 Removing the relay host configuration 1. Type 6 in the fwMailCfg menu to display the relay host configuration menu. 1 Display Relay Host configuration 2 Set Relay Host IP 3 Remove Relay Host configuration 4 Quit 2. Type 3 to remove the configuration. Fabric Watch Administrator - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 84
6 Fabric Watch notification 60 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 85
areas, such as RX Performance, for which Port Fencing is not supported, you will not be able to set or apply the changes on alarms. 2. Navigate to a specific class and area with the fwConfigure command. switch:admin> fwconfigure 1 : Environment class 2 : SFP class 3 : Port Guide 61 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 86
14 7. Set the alarm for Port Fencing (32) by typing 32 at the Enter above alarm matrix prompt. Errlog-1, SnmpTrap-2, PortLogLock-4 RapiTrap-8, EmailAlert-16, PortFencing-32 Valid alarm matrix is 63 Enter above alarm matrix => : (0..63) [0] 32 62 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 87
Above Custom as 32, and then base 15 : change inBetween alarm 6 : change custom low 16 Default 2 : custom Enter alarm level type => : (1..2) [1] 2 9. Select custom by typing 2 at the Enter alarm level type prompt. 10. Select apply threshold alarm changes by typing 16 Guide 63 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 88
unit 14 : change above alarm 5 : change custom time base 15 : change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom high (1..18) [18] 9 14. Type Enter until you reach the switch command prompt. 64 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 89
Enter the portFencing command to display the list of operands. The portFencing menu displays. switch:admin > portFencing portFencing --show portFencing --enable -area portFencing ) Link reset Protocol error State changes Fabric Watch Administrator's Guide 65 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 90
7 Configuring port fencing using the portFencing command 66 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 91
the default, exits the fwConfigure menu. NOTE For switches with Optical) class 7 : Alpa Performance Monitor class (not supported) 8 : EE Performance Monitor class 9 : Filter Performance default, returns you to the previous selection screen. Fabric Watch Administrator's Guide 67 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 92
an area => : (1..10) [10] 4 6. Type the number 4, advanced configuration, for a list of advanced configuration options, which are detailed in Table 12. 68 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 93
base . Every time the switch is rebooted, this option memory. Every time the switch is rebooted, this option default The required threshold column and custom threshold information. Obsolete Obsolete Changes the time base for the area, The required time base default and custom event settings - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 94
to the threshold and event setting areas of the screen are confirmed before leaving advanced configuration, or the changes are lost. 70 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 95
only marginal ports To view only faulty ports To view only offline ports You can generate the following types of reports using Fabric Watch: • Switch Availability report • Switch Health report • Switch Status Policy report • Port Detail report Fabric Watch Administrator's Guide 71 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 96
marginal or faulty ports that can affect throughput or switch performance. You can generate reports from the command LB 100 0 0 0 2/6 U 0 0 0 100 2/7 U 0 0 0 100 2/8 U 0 0 0 100 2/9 U 0 0 0 100 2/10 T 100 0 0 0 72 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 97
based on the currently-configured policy settings. • High-level state of the switch, the power switch health report. NOTE Switch health Switch Health report. Example : Switch Health Report cp0 login: admin Password: Sat 240 :admin> switchstatusshow Switch Health Report Switch Name: Sat 240 IP - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 98
platforms such as the Brocade 48000 director or the DCX Backbone. For modular switches, the switch status policy report also contains information on the WWN, Blade, and CP. For standalone switches such as the Brocade 4100 and 5000, the WWN, Blade, CP, and core blade information is not displayed - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 99
: Port detail report Port Detail Report Report time: 04/24/2007 03:40:10 AM Switch Name:geo_hi IP address:1080::8:800:200C:417A Port Exception report [by All] --------Port-Errors SFP-Errors---Port# 214 G HEALTHY 000:00 215 G HEALTHY 000:00 Fabric Watch Administrator's Guide 75 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 100
218 VE HEALTHY 061:19 219 VE HEALTHY 003:37 220 VE HEALTHY 002:48 221 VE HEALTHY 061:19 222 VE HEALTHY 061:19 223 VE HEALTHY mode based on the switch status policy. STM SFP temperature is out of specifications. SRX SFP receive power is out of specifications. STX SFP transmit power is - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 101
use the listed monitors. TABLE 15 Monitor Switch status policy factors Health factors Power Supplies Power supply thresholds detect absent or failed power supplies, and power supplies that are not in the correct slot for redundancy. When intelligent blades like the FR4-18i are in the 48000 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 102
Marginal or Down based on your system requirements for each policy or parameter. The following example shows a switch status policy for Switch Status Policy Report. See Chapter 9, "Fabric Watch Reports" for more details about the Switch Status Policy Report. 78 Fabric Watch Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 103
a Telnet connection with a switch. 2. Log in using administrative and alarm action. To accept the default value for each FRU, press Return. 16 Configurable Alarm Actions are: Errlog-1, E-mail-16 Slot Alarm State: (0..31) [31] Slot Alarm Action: (0..17) [1] Power Supply Alarm State: (0..31) [0] Power - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 104
using the Absent, Off, and Faulty states, add the assigned values and enter that value at the prompt. In this case, the values are 1, 8, and 16, respectively, and the total is 25. 80 Fabric Watch Administrator - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 105
in a virtual fabric (VF) environment. System monitoring is disabled by default. You must run both the --config -mem and the --config - sysMonitor command to display the list of operands. The sysMonitor menu displays. switch:admin > sysMonitor sysMonitor --config [-poll ] - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 106
default value is 10. • retry - Specifies the number of retries before Fabric Watch takes action. The default and raslog. The default value is none. default value is 10. • retry - Specifies the number of retries before Fabric Watch takes action. The default snmp and raslog. The default value is none. - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 107
--config cpu -poll 20 -retry 4 -limit 70 -action snmp Displaying the current CPU usage threshold switch:admin > sysMonitor --show cpu CPU Usage: CPU Usage : 1% CPU Usage Limit :75% Number of Retries :3 Polling Interval :10 seconds Actions :none Fabric Watch Administrator's Guide 83 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 108
11 System monitoring using the sysMonitor command 84 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 109
to custom Set boundary and alarm level to default Configures the Fabric Watch port fencing feature. switch status policy parameters Show switch status policy parameters Show overall switch status Changes the syslog facility. Show switch temperature readings Fabric Watch Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 110
A In this appendix 86 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 111
switch hardware. Using the the default default Fabric Watch configuration settings when running Fabric OS v6.3.0 on the supported Brocade platforms listed under "Supported hardware and software" on page xviii. Values for earlier versions of Fabric OS might differ. Fabric Watch Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 112
reference manual for differences in actual environmental requirements. NOTE Fabric Watch no longer supports fan monitoring. Event Manager (EM) now manages fan monitoring and the switch status is calculated based on the fan status reported by EM. TABLE 16 Area Environment class default settings - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 113
settings (Continued) Description Default threshold settings Default alarm settings Threshold state Power Supply Monitors power supply condition Brocade 48000 Low: 0 High: 60 Buffer: 10 Brocade DCX Low: 0 High: 70 Buffer: 10 Brocade DCX-4S Low: 0 High: 75 Buffer: 10 Time Base: None Low: 1 High - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 114
TABLE 17 Fabric class default settings Area Description Default threshold Default alarm settings settings Threshold state Domain ID Changes Monitors forcible DOMAIN ID changes Unit: D_ID Changes Time Base: none Low: 0 Informative 90 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 115
Base: none filtered out by the port Low: 0 High: 0 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Informative Informative Table 19 provides default Performance Monitor class default settings Area Description Default threshold Default alarm settings Threshold - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 116
default settings Area Description Default threshold Default alarm settings settings Threshold state Class 3 Discards Class 3 discards frames due to timeout or destination unreachable. Unit: Errors Time Base Time Base: : Errors of link resets sent by Time Base: minute a given port (LR-Out) Base - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 117
default settings (Continued) Description Default threshold settings Default alarm settings Threshold state Receive (Rx) Performance Monitors receive rate, Unit: Percentage (%) by percentage Time Base Unit: Changes Time Base: minute Low:0 Unit: Percentage (%) Time Base: minute Low: 0 High - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 118
Default threshold settings Default alarm settings Threshold state Class 3 Discards Class 3 discards frames due to timeout or destination unreachable. Unit: Errors Time Base: minute Low: 0 High: 5 Buffer: 0 Invalid CRC Count Monitors the number Unit: Errors of CRC errors Time Base - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 119
default settings (Continued) Description Default threshold settings Default alarm settings Threshold state Primitive Sequence Protocol Error Monitors the number Unit: Errors of primitive sequence Time Base Base Changes Time Base: minute Low Base Base for the port Time Base: minute at the time Base - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 120
Description Default threshold settings Default alarm settings Threshold state Class 3 Discards Class 3 discards frames due to timeout or destination unreachable. Unit: Errors Time Base: minute Low: 0 High: Informative Out_of_range In_range 96 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 121
default settings (Continued) Description Default threshold settings Default alarm settings Threshold state Link Failure Count Monitors the number of link failures Loss of Signal Count Monitors the number of signal loss errors Unit: Errors Time Base Administrator's Guide 97 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 122
Security class. TABLE 25 Security class default settings Area Description Default threshold settings Default alarm settings API Violations Monitors API violations Unit: Violations Time Base: minute Low: 1 High: 2 Out_of_range In_range 98 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 123
25 Area Security class default settings (Continued) Description Default threshold settings Default alarm settings Invalid Certificates Monitors invalid certificates Unit: Violations Time Base: minute Low: 1 Out_of_range In_range Fabric Watch Administrator's Guide 99 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 124
TABLE 25 Area Security class default settings (Continued) Description Default threshold settings Default alarm settings SLAP Bad Packets Monitors SLAP bad packets Unit: Violations Time Base: minute Low: 1 High Out_of_range In_range 100 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 125
Power Monitors transmit power in µWatts Unit: Degrees C Time Base: none Low: -10 High: 85 Buffer: 3 Unit: µWatts Time Base: none Low: 0 High: 5000 Buffer: 25 Default Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Normal Fabric Watch Administrator's Guide 101 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 126
B Class default settings 102 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 127
command shortcuts Table 27 lists the command shortcuts that are used in the examples in this appendix. TABLE 27 Fabric Watch portThConfig command shortcuts Full operand name Shortcut -value -va -area -ar -highthreshold -h -lowthreshold -l -action -ac Fabric Watch Administrator - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 128
pe -h -tr below -ac raslog,snmp,email,portlog portthconfig --set port -ar pe -l -va 3 -tr below -ac raslog,snmp,email,portlog 104 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 129
-ar tu -h -tr below -ac raslog,snmp,email,portlog portthconfig --set port -ar tu -l -va 1 -tr below -ac raslog,snmp,email,portlog Fabric Watch Administrator's Guide 105 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 130
pe -h -tr below -ac raslog,snmp,email,portlog portthconfig --set e-port -ar pe -l -va 3 -tr below -ac raslog,snmp,email,portlog 106 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 131
-util -h -tr below -ac raslog,snmp,email,portlog portthconfig --set e-port -ar trunk-util -l -va 1 -tr below -ac raslog,snmp,email,portlog Fabric Watch Administrator's Guide 107 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 132
-h -tr below -ac raslog,snmp,email,portlog portthconfig --set fop-port -ar los -l -va 1 -tr below -ac raslog,snmp,email,portlog 108 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 133
-h -tr below -ac raslog,snmp,email,portlog portthconfig --set fop-port -ar trunk-util -l -va 1 -tr below -ac raslog,snmp,email,portlog Fabric Watch Administrator's Guide 109 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 134
C Port Type: FOP_Port 110 Fabric Watch Administrator's Guide 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 135
Switch Binding Security Authentication Security N_Port connection Not Allowed Link Level (hot I/O) Link Transition Threshold Exceeded Protocol ISL Fencing Description Firmware Class / Area FOS Support detected by the Authentication Services subsystem (the Radius Guide 111 53-1001342-01 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 136
Subtype ISL Segmentation ISL Security Error ISL Protocol Error Fabric Binding Violation FLOGI Description Firmware Class / Area FOS Support An E_Port has segmented, exceeding the threshold limit. The attached switch previously placed in the Invalid Attachment state has persisted in consuming - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 137
14 performance monitor class, 15 port class, 15 resource class, 16 security class, 17 SFP class, 18 areas, 13 B 11 subclasses, 11 Fabric Watch Administrator's Guide 53-1001342-01 commands configdownload, 34 event behavior, 49 D data values, 4 default settings environment class, 88 Fabric class, 90 - HP StorageWorks 8/80 | Brocade Fabric Watch Administrator's Guide v6.3.0 (53-100 - Page 138
27 N notification configuration alarms, 52 API, 51 relaying host IP configuration, 58 values, 53 notification methods, 2, 50 API, resource class area, 16 S security class areas, 17 setting time base, 21 SFP bases, 21 time bases, 21 set to other than none, 21 time base set to none, 21