HP Surestore 80fx Adding 2 Drives to the C1150 Series Jukebox - C1154-90001
HP Surestore 80fx - Optical Jukebox Manual
View all HP Surestore 80fx manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Surestore 80fx manual content summary:
- HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 1
, obtain the following: * The downloadable code required for this upgrade. FTP this code from hpgrsg.gr.hp.com (15.38.89.10) using an "anonymous" login. Further download instructions are available at that address. * A PC with a SCSI interface and appropriate cables * A utility to download the - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 2
©Hewlett-Packard Company, 1996 - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 3
a performance upgrade, install 32 magazine slots (C1155F/G/H) Upgraded to equivalent of: (# of drives) C1160F/G/H (4 drives)a ESD Precautions The optical disk jukebox contains very sensitive electrical components. It is EXTREMELY IMPORTANT that you follow the proper procedures for preventing ESD - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 4
cables - # C1170-60x62 • 2 - drive power cables - # C1170-60x54 • 5 - threaded RLG screws - # 0515-2282 • 11 - M3x6 T10 screws - # 0515-2382 • 1 - these instructions Note The "x" in the part numbers listed in the following parts tables represents a number from "0" to "9" depending on the revision of - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 5
so they can be replaced to their ORIGINAL positions. Failure to follow this practice results in a serious loss of file system integrity. 1. Look in the jukebox front "window" and make sure that there are no disks in any drive. Use the control panel to eject any disk still in a drive 2. Bring - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 6
Installing the 2-Drive Upgrade Caution Put on a grounding strap to work inside the outer shell of this jukebox. 1. Remove the left, right and back panels. Refer to Figures 1 and 2. Figure 1: Right-side panel access a. Remove the T-20 screw that holds the bottom edge - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 7
Rear, overall arrows, screws Figure 2: Rear access panel d. Remove the 7 T-20 screws around the outer edge of the panel. e. Remove the single screw underneath the bottom of the panel. f. Rotate the back panel back and lift if off the frame. 7 - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 8
Installing the 2-Drive Upgrade Note There is 1 drive installed in each drive enclosure. To add 2 drives, you will install drive enclosures where the air baffle plate is currently installed. 1. Remove current drive cables from the interposer PCA. 2. Remove the air baffle plate. Refer to Figure 3 for - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 9
Figure 4: Ensuring drive DIP switches are all OFF 4. Install drives in drive enclosures (1 drive in each enclosure). a. Remove the top cable access plate of each drive enclosure by removing the 2 T-10 screws which hold the plate onto the enclosure. b. Insert the drive interface, SCSI and power - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 10
c. Insert the single drive into the enclosure and position it near the cables at the rear, and in the upper portion of the enclosure - do not mount the drive at this point - the drive interface cable and clip must be mounted in the next step. d. Connect the drive interface cable and clip. Put the - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 11
side of the enclosure slide over the tabs sticking out from each side of the stack. Two tabs near the front of the stack will support the rear portion of the enclosure. (See the next Figure.) After inserting the drive enclosure, try moving the drive up and down a little. If the - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 12
PCA cable layout 7. Download code to the controller PCA and drives. 8. Run the Wellness Test from the control panel to verify installation. 9. Label the jukebox. Place the product upgrade label that came with the capacity upgrade Use the C1160 label. Do not cover the serial number. Refer to Figure - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 13
Note: The label does NOT cover the original serial number. Hewlett-Packard Co. Upgraded to C1170F S/N 9999999999 Made in U.S.A. Example label Original label Figure 11: Correct label position 13 - HP Surestore 80fx | Adding 2 Drives to the C1150 Series Jukebox - C1154-90001 - Page 14
14
Adding 2 Drives to the
C1150 Series Jukebox
HP Part No.
C1154-90001
Printed in USA June, 1996
Edition 1
0696
Important! Read This First
BEFORE
starting this supgrade, obtain the following:
*
The downloadable code required for this upgrade. FTP this code
* A PC with a SCSI interface and appropriate cables
from
hpgrsg.gr.hp.com (15.38.89.10
)
using an "anonymous" login.
Further download instructions are available at that address.
* A utility to download the code - DOWNLD2 or
HP TOOLSET
(Version 1.95ce
This upgrade requires code to be
downloaded to the controller PCA and the drives.
or later) from CoComp