- HP Surestore Tape Library Model 20/700 | Cartridge Access Port Installation Inst - Page 1
HP Surestore Tape Library 20/700 A5601A Cartridge Access Port Installation Instruction (for HP field service use only) CAUTION: The HP tape library Cartridge Access Port is not customer installable or replaceable. Any servicing, adjustment, maintenance or repair must be performed only by authorized - HP Surestore Tape Library Model 20/700 | Cartridge Access Port Installation Inst - Page 2
s CAP Install 1. Have the operator take the library and all tape drives offline and power off the tape library. 2. Obtain key and open front cartridge area door of the tape library. 3. Remove CAP A EMI SHIELD (refer to item 3 of the graphic) and window assembly from CAP B mounting location and set - HP Surestore Tape Library Model 20/700 | Cartridge Access Port Installation Inst - Page 3
No. 632 x 3/8 Torx Pan Head screws. Please note that some older models of 20/700 require only three screws. Check CAP A for rotation by manually rotating the cylindrical door. If the CAP cannot rotate freely, realign the CAP EMI SHIELD. 5. Remove CAP assembly from packaging. 6. Install CAP into CAP - HP Surestore Tape Library Model 20/700 | Cartridge Access Port Installation Inst - Page 4
Figure 2. CAP Installation CAP Installation (a5601a_02) 6. 6-32 x 3/8-in. Pan Head Screw for CAP B Shield (5x) 7. CAP A EMI Shield 8. Top CAP Mounting Bracket 9. 1/4-20 x 1/2-in. Long Screw (4x) 10. CAP B EMI Shield 11. Bottom CAP Mounting Bracket 12. Locating Pin 13. 6-32 x 3/8-in. Pan Head Screw - HP Surestore Tape Library Model 20/700 | Cartridge Access Port Installation Inst - Page 5
Head screws. Check CAP B for rotation by manually rotating the cylindrical door. Please note that some older models of 20/700 of Figure 3). 11. Install the magazines into the CAP with the handle facing up by guiding the notches on the magazine into the slots on the CAP (see Figure 4). 62104 5 - HP Surestore Tape Library Model 20/700 | Cartridge Access Port Installation Inst - Page 6
Figure 4. CAP Installation CAP Installation (a5601a_02) 20. Magazine 12. Close LSM doors and lock. 13. Verify that the tape library initializes and audits properly. 14. Test the operation of CAP A and CAP B by pressing CAP B button on OP panel. Open and Close. 15. Return unit to customer. 62104
62104
1
HP Surestore Tape Library 20/700 A5601A
Cartridge Access Port Installation
Instruction
(for HP field service use only)
CAUTION:
The HP tape library Cartridge Access Port is not customer installable or
replaceable.
Any servicing, adjustment, maintenance or repair must be performed only
by authorized HP service-trained personnel.
Note to Customer Engineer:
This installation may add new technology to the library
that older user’s guides do not address.
Please remind the customer that the latest user
documentation is available from the HP Customer Care website:
support
.
■
Materials Included
■
Installation Notes
•
Confirm with the customer System Administrator that the tape library can be powered
off.
•
Observe proper power down and power on procedures, as described in the
Installation
or
Service Manual
.
Table 1. Materials List
Part
Quantity
I/I CAP
1
CAP TLA
1
6-32 x 3/8-in. Torx Screws
10
1/4-20 x 1/2 Long Screws
4
CAP B EMI Shield
1
Five Cell Magazine Assembly
4