HP T1000 IEC-320-C14 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3
HP T1000 IEC-320-C14 Manual
View all HP T1000 IEC-320-C14 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP T1000 IEC-320-C14 manual content summary:
- HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 1
HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide Part Number 505922-002 July 2009 (Second Edition) - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 2
for technical or editorial errors or omissions contained herein. Audience assumptions This guide is for the person who operates, configures, maintains, and troubleshoots UPSs. HP assumes you are qualified in the servicing of high-voltage equipment and trained in recognizing hazards in products with - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 3
. CAUTION: REFER TO OPERATOR'S MANUAL - Refer to your operator's manual for additional information, such as important operating and maintenance instructions. RJ-45 RECEPTACLE - For the output receptacles ( or to de‐energize the output receptacles ( indicator is off). indicator illuminates) - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 4
installed and used in accordance with the instructions, may cause harmful interference to radio communications , Mail Stop 530113 Houston, Texas 77269-2000 S 1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls indicated by the following conformity marking placed on the - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 5
, Germany This symbol on the product or on its packaging indicates that this product must not be disposed of with your other HP, an authorized HP Partner, or their agents. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 6
workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. S Use conductive field service tools. S Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 7
Support 29 Before You Contact HP 29 HP Contact Information 30 9 Warranty Infromation 31 Limited Warranty 31 $250,000 Computer Load Protection Guarantee 31 Pre-Failure Battery Warranty 31 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 8
of network devices makes it the perfect choice to protect your LANs, servers, workstations, and other electrical equipment. Figure 1 shows the HP T750 G2 UPS. Figure 1 HP T750 G2 UPS HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 1 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 9
, or other telecommunications equipment. S Advanced power management with the HP Power Manager software for graceful shutdowns and power monitoring. S Backed by worldwide agency approvals. 2 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 10
. S Replace batteries with the same number and type of batteries as originally installed in the UPS. S If the UPS requires any type of transportation, disconnect the internal UPS batteries before transporting (see page 17). HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 11
service representative. Connecting the UPS Internal Battery To ensure proper battery operation: 1 Verify that the UPS power is off and unplugged. 2 Pull the top left corner forward and remove the UPS front bezel (see Figure 2). Figure 2 Removing the UPS Front Bezel 4 HP T750 G2, HP T750J, HP - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 12
batteries. This is normal and does not damage the unit or present any safety concern. Figure 5 Connecting the Internal Battery Connector 6 Replace the metal battery cover. 7 Replace the UPS front bezel. HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 13
alarm indicator stays on, see Table 10 on page 28. NOTE: The batteries charge to 90% capacity in approximately 3 hours. However, to fully charge, HP recommends that the batteries charge for 6 to 24 hours after installation or long-term storage. 6 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 14
Cord with 5‐15 Plug Figure 7 HP T750 G2 120V Rear Panel Serial Port Site Wiring Fault Indicator DIP Switches USB Port Fan Network Figure 8 HP T750J 100V and HP T1000 G3 120V Rear Panel HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 15
Serial Port Fan USB Port Network Transient Protector Four 10A, IEC-320 Receptacles Two 10A, IEC-320 Receptacles 10A, IEC-320 Input Connector Figure 11 HP T1000 G3, 230V Rear Panel 8 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 16
INSTALLATION DIP Switches Serial Port Fan USB Port Network Transient Protector Six 10A, IEC-320 Receptacles 10A, IEC-320 Input Connector Figure 12 HP T1500 G3, 230V Rear Panel HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 9 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 17
for two seconds. The UPS starts up in Battery mode and supplies battery power to your equipment. When the UPS starts on battery, it does not conduct a self‐test to conserve battery power. 10 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 18
Power On Indicator (green) On Battery Indicator (yellow) Overload Indicator (red) Service Indicator (red) Figure 13 UPS Front Panel If the UPS beeps or a UPS alarm indicator stays on, see Table 10 on page 28 to identify and correct the problem. HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 19
to initiate the self‐test. During the five-second test, the bar graph indicators cycle through twice. If the UPS beeps or a UPS alarm indicator stays on, see "Troubleshooting" on page 27. 12 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 20
configuration S USB port and serial port S Network transient protector S HP Power Manager software The DIP switches on the rear panel of each unit (see Figure ON Figure 14 DIP Switches HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 13 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 21
end of the USB cable to the USB port on your computer. USB Port Figure 15 The USB Port 2 Install the HP Power Manager software according to the instructions provided with the software. 14 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 22
HP Power Manager software can exchange data with the UPS. The software Assignment Pin Number Signal Name Function 1 Low Batt Low battery relay contact; 20 mA, 30 Vdc contact rating HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 15 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 23
latest version of HP Power Manager software, see the HP website (http://www.hp.com/go/rackandpower). NOTE: To install and configure the software, see the software user guide. The software user guide is available for download from the HP website (http://www.hp.com/go/rackandpower). HP Power Manager - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 24
and turned off. 2 Pull the top left corner forward and remove the UPS front bezel (see Figure 18). Figure 18 Removing the UPS Front Bezel HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 17 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 25
storage. Check the battery recharge date on the shipping carton label. If the date has passed and the battery was never recharged, do not use the UPS. Contact your service representative. 18 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 26
UPS unit NA T1500 UPS unit INTL T1500J UPS unit JPN Spare part number 502538-001 502539-001 502540-001 502532-001 502533-001 538256-001 502534-001 502535-001 538257-001 502536-001 502537-001 538258-001 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 27
you pull it out of the UPS. To replace the UPS internal battery: 1 Pull the top left corner forward and remove the UPS front bezel (see Figure 21). Figure 21 Removing the UPS Front Bezel 20 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 28
remove the battery lead from the cable retainer. 5 Carefully disconnect the black battery cable to the UPS. 5 3 4 Figure 23 Removing the Battery (HP T750 G2, HP T750J and HP T1000 G3 Models) HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 29
On Battery) indicator illuminates and the (Service) indicator flashes. Check the battery connections and be sure the battery is fully charged. Call your service representative if the problem persists. 22 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 30
battery or UPS. W A R N I N G S Do not dispose of the battery or batteries in a fire. Batteries may explode. Proper disposal of batteries local recycling/reuse or hazardous waste center. HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 23 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 31
Environmental and safety S Battery 100V Models HP T750J (HSTNR-U017-N) HP T1000J (HSTNR-U018-N) HP T1500J (HSTNR-U018-J) 120V Models HP T750 G2 (HSTNR-U016-N) HP T1000 G3 (HSTNR-U017-N) HP T1500 G3 (HSTNR-U018-N) 230V Models HP T750 G2 (HSTNR-U016-I) HP T1000 G3 (HSTNR-U017-I) HP T1500 G3 (HSTNR - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 32
nominal inputs) Power Factor Regulation (Normal mode) Regulation (Battery mode), Nominal Voltage ±5% Voltage Waveform Overcurrent Protection Output EN 62040-2, FCC Part 15, ICES-003, VCCI HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 25 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 33
8 900 603 6 1000 670 5 1200 804 1400 938 NOTE Battery times are approximate and may vary depending on the load configuration and battery charge. 1400 58 41 28 19 14 10 8 6 5 26 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 34
condition is resolved. Have a qualified electrician correct the wiring fault. The UPS operates when the indicator is illuminated, but does not provide rated noise and surge suppression. HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 27 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 35
battery connections and be sure the battery is fully charged. If the (Service) indicator still flashes, see "Replacing Batteries" on page 20. Call your service representative if the problem persists. 28 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 36
model name and number S Product identification number S Applicable error messages S Add-on boards or hardware S Third-party hardware or software S Operating system type and revision level HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 29 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 37
Care Packs, refer to the HP website (http://www.hp.com/hps). S In other locations, see the Contact HP worldwide (in English) webpage (http://welcome.hp.com/country/us/en/wwcontact.html). 30 HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3, and HP T1500J UPS Models User Guide S 505922-002 - HP T1000 IEC-320-C14 | HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500 G3 - Page 38
its battery, is replaced. A Pre-Failure Battery warning is given 30 days before a battery failure. The warning is indicated in one or both of the following ways: S An LED showing the battery is low S Notification from power management software HP T750 G2, HP T750J, HP T1000 G3, HP T1000J, HP T1500
HP T750 G2, HP T750J, HP T1000 G3,
HP T1000J, HP T1500 G3, and
HP T1500J UPS Models
User Guide
Part Number 505922-002
July 2009 (Second Edition)