- HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 1
HP Kayak XM600 PC Workstation Technical Reference Manual - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 2
part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Hewlett-Packard Company. Adaptec® is a registered trademark of Adaptec, Inc. Adobe and Acrobat are trademarks of Adobe Systems Hewlett-Packard France Business Desktop Division - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 3
Rear View 15 Internal Features 15 HP Kayak XM600 Desktop Front Panel 16 HP Kayak XM600 Minitower Front Panel 17 HP Kayak XM600 Desktop Specifications and Characteristics. . . . 18 Desktop Physical Characteristics 18 Desktop Electrical Specifications 18 Desktop Power Consumption and Cooling 19 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 4
Contents 2 System Board System Board Overview 34 Architectural View 35 Accessory Board Slots 36 AGP Pro Universal Slot (Minitower Models 36 AGP Pro Universal Slot (Desktop Models 37 PCI Slots 38 System Board Switches 40 Chipset 41 Memory Controller Hub (MCH) 82820 42 Accelerated Graphics - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 5
GVX1 77 ELSA Synergy II Graphics Card 79 Network Cards 81 HP 10/100 TX PCI LAN Interface 81 Supported LAN Cards 83 3COM NIC (Network Interconnect) LAN Card 83 PCI connector 89 PCI Bus 89 Terminators 89 Flash memory 89 4 Mass Storage Devices Flexible Disk Drives 91 Hard Disk Drives 91 CD - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 6
Configuration Utility 105 BIOS Addresses 106 System Memory Map 106 HP I/O Port Map (I/O Addresses Used by the System 107 DMA Channel System Boot Phase 114 Run-Time Errors 115 Main Menu (Minitower models only 116 Order in Which POST Tests Are Performed 118 Error Message Summary 126 Beep Codes - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 7
Preface This manual is a technical reference and BIOS document for engineers and technicians providing system level support. It is instructions, refer to the user guide delivered with the PC Workstation. Conventions The following conventions are used throughout this manual to identify specific - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 8
Online documentation can be obtained from the HP World Wide Web site: www.hp.com/go/kayaksupport. Ì HP Kayak XM600 PC Workstation User's Guide - Desktop - D8368-90001. Minitower - D8369-900011. Ì HP Kayak XM600 PC Workstation Troubleshooting Guide - Desktop and Minitower versions are available in - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 9
533 MHz and upwards with a 133 MHz FSB. The HP Kayak XM600 PC Workstations include integrated VRMs (Voltage Regulator Module) on the system board. A separate VRM is not required. Cache Memory (integrated • Level-One: 16 KB code, 16 KB data. in processor package) • Level-Two: i256 KB or 512 KB - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 10
RDRAM modules. • Two DIMM sockets supporting SDRAM 100 MHz memory modules. Models are supplied with non-ECC SDRAM modules. A Memory Expansion Card is supplied uniquely with SDRAM models and is installed in the pre-defined socket on the system board. Up-to-date memory upgrades are listed on the HP - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 11
1 System Overview HP Kayak XM600 PC Workstation Overview Feature Mass Storage SCSI Controller IDE Controller Video Controllers Accessory Card Slots Description Desktop Minitower Five mass storage shelves supporting: • One front-access, third-height, floppy disk drive • Two front-access, half- - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 12
Kayak XM600 PC Workstation Overview Feature LAN Card CD-ROM Drive Audio HP UltraFlow Cooling System System Board Connectors: Rear Connectors (color coded) Description Desktop Minitower All models are supplied with an HP 10/100BT PCI Ethernet Adapter LAN card installed in PCI slot 5, supporting - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 13
1 System Overview Package for the Desktop Models Package for the Desktop Models The following two diagrams show the front and rear views of the HP Kayak XM600 Desktop PC Workstation. Front and Side Views Power Supply Unit Processor Fan HP UltraFlow Airflow Guide Secondary Hard Disk Drive tray - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 14
of the HP Kayak XM600 Minitower PC Workstation. Front and Side Views HP UltraFlow Airflow Guide Rear Fan Spare mounting rails (not shown) for: - 3.5-inch (short green) devices (for example, zip drive), - 5.25-inch (long green) devices, - 3.5-inch (short blue) hard disk drives Power Supply Unit - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 15
of the HP Kayak XM600 PC Workstation is constructed around: Memory Controller Hub (MCH), Input/Output Controller Hub (ICH) and the Host bus. The HP Kayak XM600 PC Workstation can support up to two Pentium III processors. This processor is described on page 67. The components of the system board are - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 16
1 System Overview HP Kayak XM600 Desktop Front Panel HP Kayak XM600 Desktop Front Panel The front panel of the HP Kayak XM600 Desktop PC Workstation has the following features: Reset Button Hard Disk Activity Light Power On/Off Button • On/Off LED. There are five states: Blank. Indicates that - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 17
1 System Overview HP Kayak XM600 Minitower Front Panel HP Kayak XM600 Minitower Front Panel The front panel of HP Kayak XM600 Minitower PC Workstation has the following features: LCD Control Buttons Power On/Off Button Reset Button Hard Disk Activity Light • Liquid Crystal Display (LCD). LCD error - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 18
1 System Overview HP Kayak XM600 Desktop Specifications and Characteristics HP Kayak XM600 Desktop Specifications and Characteristics Desktop Physical Characteristics System Processing Unit Weight (excl. keyboard and display): Dimensions: Footprint: 12.5 kilograms (27.5 pounds). 45.7 cm max. (D) - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 19
NOTE 1 System Overview HP Kayak XM600 Desktop Specifications and Characteristics If the overload protection in the power supply unit is triggered, all power is immediately cut. To reset the power supply unit, remove the power cord and then determine what caused the overload and remedy it. - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 20
System Overview HP Kayak XM600 Desktop Specifications and Characteristics Desktop Environmental Specifications Environmental Specifications (System % (relative).1 8% to 85% (relative).1 Sound Power Sound Pressure LwA - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 21
1 System Overview HP Kayak XM600 Minitower Specifications and Characteristics HP Kayak XM600 Minitower Specifications and Characteristics Minitower Physical Characteristics System Processing Unit Weight (excl. keyboard and display): Dimensions: Footprint: 14.2 kilograms (31.24 pounds). 47.0 cm - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 22
NOTE 1 System Overview HP Kayak XM600 Minitower Specifications and Characteristics If the overload protection in the power supply unit is triggered, all power is immediately cut. To reset the power supply unit, remove the power cord and then determine what caused the overload and remedy it. - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 23
System Overview HP Kayak XM600 Minitower Specifications and Characteristics Minitower Environmental Specifications Environmental Specifications (System (relative).1 8% to 85% (relative).1 Sound Power Sound Pressure LwA - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 24
SE Supported Supported Supported (implemented as S3, Suspend to RAM) Supported Supported (implemented as S1, suspend) Supported Supported Not Supported Supported Windows NT 4 Supported Not Supported by Windows NT 4 Supported Windows 95 Supported Supported Supported APM only Operating System - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 25
delay Desktop Power Saving Modes and Resume Events for ACPI Systems Full On (S0) Processor Display Hard Disk Drive Active Power Planes Power Consumption Normal speed On Normal speed VCC VCCAux Supports up to 200 W Resume Events Resume Delay Suspend (S1) Halted Blanked Halted Suspend to RAM - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 26
Modes and Resume Events for ACPI Systems Full On (S0) Processor Display Hard Disk Drive Active Power Planes Power Consumption Normal speed On Normal speed VCC VCCAux Supports up to 300 W Resume Events Resume Delay Suspend (S1) Halted Blanked Halted Suspend to RAM (S3) Off Suspend to Disk (S4 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 27
bar). • The function has not been disabled by setting SW-6 to off on the system board switches. • The function has not been disabled in the "Power" menu of the Setup program. Soft Power Down When the user requests the operating system to shut down, the environment is cleared, and the computer is - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 28
HP Kayak XM600 Technical Notes PDF file No Desktop version No Minitower version 1. Refer to the Service Handbook Chapter for the availability of the localized monolingual and multilingual User's Guides. Access HP World Wide Additional online support documentation, BIOS upgrades and drivers - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 29
within the HP Kayak XM600 PC Workstation documentation set. User's Guide Product features Standard configuration. Troubleshooting Service Guide1 Handbook Introducing the PC Exploded view. Parts list. Technical Information Configuration. Technical Reference Manual Key features. Product - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 30
the PC User's Guide Full description. Troubleshooting Service Guide1 Handbook Upgrading the PC Technical Information Technical Reference Manual Supported accessories Installing accessories Configuring devices System board Full PN details Processor(s), memory, accessory boards, mass storage - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 31
1 System Overview Documentation User's Guide Troubleshooting Service Guide1 Handbook Peripheral Devices Audio Accessories Refer to Audio User's Guide for information on setting up and configuring audio accessories. Refer to online version of Audio User's Guide for information on setting up - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 32
1 System Overview Documentation 32 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 33
chapter describes the components of the system board, taking in turn the components of the Memory Controller Hub (MCH), the Input/Output Controller Hub (ICH), FirmWare Hub (FWH) and the Host Bus. The following diagram shows the HP Kayak XM600 PC Workstation system board in detail. 12-inches high 33 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 34
system board. CPU Processor 1 Connector Fan 1 AUX Power Main Power Package Intrusion Processor 2 Connector Line Out Line In MIC RIMM1 CPU Fan 2 Memory Controller Hub Main Fan (MCH) RIMM0 SDRAM Memory WOL) (MT only) Secondary IDE Floppy Connector Primary IDE HDD Thermal Sensor (MT only) - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 35
System Board Architectural View Architectural View SECC-2 cartridge Intel Pentium III Processor with L2 cache memory Intel Pentium III Processor (optional second processor) with L2 cache memory SECC-2 cartridge Address (36) Control Data (64) AGP PRO supporting RDRAM memory Fans LCD Status - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 36
33 MHz PCI slots: PCI Slot 1, PCI Slot 2, PCI Slot 3, PCI Slot 4, PCI Slot 5 System board edge (PCI Slot 1) (PCI Slot 2) (PCI Slot 3) (PCI Slot 4) (PCI Slot 5) AGP Pro Universal Slot (Minitower Models) Minitower models of the HP Kayak XM600 are equipped with a single AGP (Accelerated Graphics Port - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 37
Slot (Desktop Models) Desktop models of the HP Kayak XM600 are equipped with a single AGP (Accelerated Graphics Port) Pro Universal graphics slot. The connector accepts only standard (≤ 25 W) AGP graphics cards. AGP Pro cards (> 25 W) cannot be used - a hardware detection prevents the PC Workstation - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 38
used. The maximum supported power consumption per slot is 25W, either from the 5V or the 3.3V supply and must respect the electrical specifications of the PCI 2.2 specification. Total power consumption for the PCI slots must not exceed 60 W. The power consumption of each PCI board is automatically - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 39
only operate in 33 MHz mode. The system board and BIOS support the PCI specification 2.2. This specification supports PCI-to-PCI bridges and multi-function ICH (Input/Output Controller Hub) chip, bridge between the MCH (Memory Controller Hub), USB ports and IDE buses. • Digital audio CS4280 controller. - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 40
. Enables normal modes. ON clears CMOS memory at next boot. Retains CMOS memory. ON clears the passwords at next boot. Enables User and System Administrator passwords. ON = minitower OFF = desktop. A limited number of early HP Kayak XM600 system boards have 20 configuration switches. Switches 11-20 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 41
2 System Board Chipset MMCCHH ICH FWFHWH Chipset The Intel® 820 chipset supports RDRAM memory technology and system bus speeds up to 133 MHz, while delivering significant graphics performance enhancements through its AGP 4x graphics interface. It is comprised of the following: • The 82820 Memory - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 42
an example of the system block diagram using the MCH. SECC-2 cartridge Address (36) Control Data (64) AGP Pro (MT) or AGP 4x (DT) Connector Intel Pentium III Processor with L2 cache memory Intel Pentium III Processor (optional second processor) with L2 cache memory SECC-2 cartridge Host (also - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 43
2 System Board Memory Controller Hub (MCH) 82820 The following table shows the features that are available in the MCH Host Bridge/Controller. Feature Feature • Processor/Host Bus: Ì Supports Pentium III processor configuration at both 100 MHz and133 MHz bus speeds Ì Supports Symmetric - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 44
Board Memory Controller Hub (MCH) 82820 Feature Feature • Power Management: Ì SMRAM space re-mapping to A0000h (128 KB) Ì Supports HSEG and TSEG cacheable extended SMRAM space - 128 KB HSEG at 0FEEA0000h remapped to A0000h - TSEG is 128 KB/256 KB/512 KB/1 MB at the top of memory - No maximum - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 45
2 System Board Memory Controller Hub (MCH) 82820 AGP 4x Bus The AGP bus is a dedicated , you come closer to the theoretical maximum bandwidth. Although the maximum transfer rate is never exceeded, the overall transfer rate is increased. AGP specific transactions always use pipelining. This control - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 46
2 System Board Memory Controller Hub (MCH) 82820 AGP PCI Bus Implementation AGP Connector AGP 4x Bus (133 MHz) GX-Device 1 AGP Port Interface Pentium III Processor 820 Memory Controller Hub (MCH) 82820 I/O Controller Hub (ICH) 82801AA Main Memory Controller The main memory controller is - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 47
RDRAM memory is being used, there must be no Memory Expansion Card in the SDRAM Memory Expansion Card Socket. A maximum of two RDRAM modules can be installed in the HP Kayak XM600 PC Workstation. If only one RDRAM module is being used, it must be inserted in RIMM0 (the socket nearest the processor - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 48
2 System Board Memory Controller Hub (MCH) 82820 RDRAM models of the HP Kayak XM600 PC Workstation are supplied with 128 MB of RDRAM unbuffered ECC main memory installed in the RIMM0 socket. Memory upgrades are available in 64 MB, 128 MB, 256 MB RDRAM modules. SDRAM Memory Expansion Card Slot SDRAM - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 49
2 System Board Memory Controller Hub (MCH) 82820 Read/Write Buffers System Clocking I/O APIC The MCH defines a data buffering scheme to support the required level of concurrent operations and provide adequate sustained bandwidth between the DRAM subsystem and all other system interfaces (CPU, AGP - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 50
encapsulated in a 241-pin Ball Grid Array (BGA) package and is located on the system board just underneath the Memory Expansion Card Connector. It provides the interface between the PCI bridge (PCI Rev. 2.2 compliant with support for 32-bit 33 MHz PCI operations), PCI-to-LPC (Low Pin Count) bridge - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 51
2 System Board The Input/Output Controller Hub (82801AA) The following table shows the available ICH features. Feature Feature • Multi-function PCI Bus Interface: Ì PCI at 32-bit 33 MHz. Ì PCI Rev 2.2 Specification. Ì 133 Mbyte/sec data transfer rate. Ì Master PCI Device Support for up to six - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 52
is a two-wire serial bus. It runs at a maximum of 100 kHz. The SMBus Host interface allows the processor to communicate with SMBus slaves. The bus connects to sensor devices that monitor some of the hardware functions of the system board, both during system boot and run-time. Refer to page 57 for - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 53
exe), which provides support for the Universal Serial Bus for Windows 95 Software Release (SR) 2.0, can be obtained from the Hewlett-Packard World Wide Web site at: http://www.hp.com/go/kayaksupport. This controller, even though available in the ICH, is not used. The HP Kayak PC Workstation uses the - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 54
key functions: keeping track of the time of day and storing system data. The RTC operates on a 32.768 kHz crystal and a separate 3V lithium battery that provides up to 5 years of protection. It also supports two lockable memory ranges. By setting bits in the configuration space, two 8-byte ranges - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 55
System Board The Input/Output Controller Hub (82801AA) Devices on the PCI 32-bit 33 MHz Bus The following devices are connected to the PCI 32-bit 33 MHz bus. Intel Pentium III Processor 820 Memory slots accepting 5 V PCI cards and Universal PCI cards (support for 3.3 V or 5 V). A LAN card is - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 56
2 System Board The Input/Output Controller Hub (82801AA) Dual Chip PCI Audio Solution The integrated PCI audio solution in the PC Workstation is NT 2000 Drivers. • Compliant with PC'99. • MPU-401 interface, FM synthesizer, and Game Port. • Full duplex operation. • Advanced Power Management (PPMI - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 57
I2C bus. It is a two-wired serial bus which runs at a maximum speed of 100 kHz. It is used to monitor some of the hardware functions of the system board (such as voltage levels, temperature, fan speed, memory presence and type), both at system boot and during normal run-time. It is controlled by the - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 58
2 System Board The Input/Output Controller Hub (82801AA) • PCI slot 5, thus supporting Alert-On LAN (AOL). • ICH SMBus Master Controller 16 kHz maximum. • MaxiLife for hardware management, bus master controller. • RIMM or DIMM serial EEPROM. • Hardware Monitoring ASIC. Intel Pentium III Processor - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 59
which holds the default values for the CMOS memory (in the event of battery failure).When installing a new system board, the Serial EEPROM will have a blank serial number field. This will be detected automatically by the BIOS, which will then prompt the user for the serial number which is printed on - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 60
is 14 KB. As it exceeds the 2 KB program RAM space, a paging mechanism will swap code as it is required, based on a 512 byte buffer. The first 2 KB pages of firmware code is critical because it controls the initial power on/reset to boot the system. This initial page is checked with a null-checksum - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 61
communications bus to control the integrated circuit boards. LCD Status Panel I2C bus Serial EEPROM Speed up/slow down HP MaxiLife System Fans NOTE Hardware Monitoring ASIC AGPset Memory Memory Temperature Sensors Voltage Sensors MaxiLife is powered by VSTBY. This means that it is - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 62
2 System Board The Input/Output Controller Hub (82801AA) Keyboard, Mouse and Floppy Parallel and Serial Ports Devices on the Low Pin Count Bus The following devices are connected to the LPC bus. Intel Pentium III Processor with L2 cache memory 820 Memory Controller Hub (MCH) 82820 Host (also - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 63
2 System Board The Input/Output Controller Hub (82801AA) The Super I/O Controller (NS 87364) , EPP, compatible). Ì High speed mode (MS/HP extended capabilities port, ECP, compatible). FDC The integrated floppy disk controller (FDC) supports any combination of two of the following: tape drives - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 64
, 64 Kbyte memory sections. Ì Automated byte program and block erase through an integrated WSM (Write State Machine). • A/A Mux Interface/Mode, supporting: Ì 11-pin multiplexed address and 8-pin data I/O interface. Ì Fast on-board or out-of-system programming. • Power Supply Specifications: Ì Vcc - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 65
prior to power-up or before return from reset (RST# or INIT# low to high transition). The FWH interface works with the ICH during system operation, while (Command User Interface) serves as the control center between the FWH and A/A Mux interfaces, and internal operation of the non-volatile memory. A - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 66
onboard RIMM sockets supporting RDRAM memory. I/O Controller Hub (ICH) 82801AA The supported operating frequencies of the AGTL+ bus are 100 MHz or 133 MHz. The width of the data bus is 64 bits, while the width of the address is 36 bits. Along with the operating frequencies, the processor voltage is - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 67
signal. The bus is routed with a "Y" topology. Intel Pentium III Processor HP Kayak XM600 PC Workstations are supplied with a Pentium III processor and an integrated VRM (Voltage Regulator Module) on the system board. Because these PC Workstations do not have any VRM sockets, a VRM does not need to - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 68
Two VRMs are integrated on the system board complying with VRM specification, rev. 8.2 and 8.4. High-current and low voltage processors are supported. Processors require a dedicated power voltage to supply the CPU core and L2 cache. Each processor codes through Voltage Identification (VID) pins with - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 69
2 System Board Host Bus Configuring for Multi-Processing HP Kayak XM600 PC Workstations support Symmetric Multi-Processing (SMP). When adding a second processor, it is automatically detected so there is no specific configuration required. The "mono-processing" mode has been implemented in order to - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 70
2 System Board Assigned Device Interrupts Assigned Device Interrupts Input/Output Controller Hub Interrupts Device REQ/ GNT ID IDSEL AD[xx] Chip-set Interrupt Connection INTA INTB INTC - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 71
of 8 MB of installed video memory, which can be upgraded to a maximum of 16 MB. The Matrox Millennium G250 on-board MGA G-250 processor communicates directly with the Pentium II processor along the AGP 2X bus. The controller can be characterized as follows: • Supports full AGP 2X mode • Graphics - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 72
end scalers • Fully Direct Draw, Direct 3D, Mini Client Drivers (MCD), and OpenGL® compliant • 143 MHz SGRAM (LVTTL) memory configurations (up to 16 MB maximum) • Support for memory upgrade via 144-pin SO_DIMM memory modules (SGRAM) • Serial EEPROM video BIOS interface (32 KB) • ITU-656 and VMI-like - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 73
80Hz 80Hz 60Hz 1920x1200 76 Hz 70 Hz - 1800x1440 70 Hz2 65 Hz - 1. Your display may not support the maximum refresh rates shown here. Refer to the User's Guide supplied with your display for details of the refresh rates supported by your display. 2. Limitation due to 250 MHz RAMDAC. 73 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 74
-upgradeable), and can be characterized as follows: • Powered by the Matrox MGA-G400 chip • Full AGP 2X/AGP 4X support (up to 1GB/s bandwidth) • Integrated 300MHz RAMDAC with Ultra Sharp technology for highly saturated and separated colors • Matrox DualHead Display technology with PowerDesk desktop - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 75
/refresh-rate combination is limited by a combination of the display driver, the graphics device, and the video memory. If the resolution/refresh-rate combination is set higher than the display can support, you risk damaging the display. The tables below summarize the 2D and 3D video resolutions - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 76
3 Interface Cards Graphics Cards Maximum Refresh Rates Resolution (4:3 aspect ratio) Main Display (8-/16-/24-/32-bit) Second Display (16-/32-bit) 640x480 800x600 1024x768 1152x864 1280x1024 1600x1200 1600x1280 1800x1440 1920x1440 2048x1536 200 Hz 200Hz 160 Hz 140 Hz 120 Hz 100 Hz 90 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 77
hardware, freeing the processor for other applications • OpenGL specific extensions that doubles the performance under AutoCad • Innovative virtual textures technology, using on-board graphics memory to cache large textures • Multi-screen support (with additional PCI cards) • Supports 16: 10 wide - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 78
GVX1 graphics card. Video Memory The video memory, also known as SGRAM, is a local block of RAM for holding major data display driver, the graphics device, and the video memory. If the resolution/refresh-rate combination is set higher than the display can support, you risk damaging the display - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 79
for AutoCAD 2000 that doubles performance • PowerThreads™ SSE OpenGL drivers fully tested with all leading professional graphics applications Specifications • Full AGP 2X/AGP 4X support • RIVA TNT2 (NVIDIA) graphics processors • VESA 3 (flash ROM) • Integrated 300 MHz RAMDAC • 3D standards: Hardware - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 80
, and the video memory. If the resolution/refresh-rate combination is set higher than the display can support, you risk damaging the display. The table below summarizes the 3D video resolutions and refresh rates that are supported. Display resolution Color depth 640 x 480 800 x 600 8-bit, 16-bit - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 81
3 Interface Cards Network Cards Network Cards Most HP Kayak XM600 PC Workstation models are supplied with an HP 10/100 TX LAN card. A description of this card and the features of other supported LAN cards is provided in this section. HP 10/100 TX PCI LAN Interface The 10/100 TX LAN Interface is a 32 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 82
Management 1.2, • PCI Power Management 1.1, • WfM 2.0 compliant, ACPI. Manageability • Desktop Management Interface (DMI) 2.0 Dynamic driver, • DMI 2.0 SNMP mapper, • PXE 2.0 Flashable BootROM (optional on socket). Diagnostic • Mac address DOS report tool, • User Diag for DOS. HP 10/100 TX PCI - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 83
are supported on the HP Kayak XM600 PC Workstation. 3COM NIC (Network Interconnect) LAN Card 3COM NIC LAN Card Features Feature Description Interface 32-bit 10/100 BT full duplex RJ LAN Port. LED Labels Three LEDs: • activity, • 10 MB/s speed, • 100 MB/s speed. PCI 2.2 Specification, PC - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 84
3 Interface Cards Network Cards 3COM LAN Card LED Descriptions LED Description Flashing 10 LNK GREEN: Link integrity Reversed polarity 100 LNK GREEN: Link integrity Reversed polarity Yellow: Network traffic ACT Port traffic for present either speed Steady - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 85
LED ACT/LNK On Adapter and hub are receiving power. Cable connection is good. Flashing Receiving or sending packets 100 TX Operating at 100 Mbps N/A Off Adapter and hub are not receiving power. Cable connection could be faulty or there is a driver configuration problem. Operating at 10 Mbps 85 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 86
Some HP Kayak XM600 PC Workstation models are supplied with an Ultra2 SCSI PCI Adapter card. Up to a total of 15 devices (internal and external) can be supported by of the Ultra2 SCSI PCI Adapter card comes from the on-board LSI Logic SYM53C895 PCI-Ultra2 single chip controller. The ability to - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 87
Supported SCSI Rates Number of SCSI Devices SCSI Connectors BIOS Serial EEProm Operating Systems Description • Complies with PCI 2.1 Specification connector on the system board. • On-board, upgradeable BIOS in Flash ROM. • On-board serial EEProm for supported inside the XM600 Minitower models). 87 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 88
of SCSI SCRIPTS® instructions to save PCI bus overhead. • Supports SCSI SCRIPTS Load and Store instructions for more efficient moving of data between memory and chip register space. • Includes 4 KB of internal RAM for SCRIPTS instruction storage to reduce or eliminate instruction fetches over the - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 89
of differential SCSI without cost of external differential transceivers power supplies lines. The 3,3 V is supplied by an on-board regulator. PCI Bus • Complies with PCI Specification 2.1. • Supports 32-bit, 33 MHz PCI Bus. • Supports mode. Flash memory The flash memory stores the SCSI BIOS. Refer to - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 90
3 Interface Cards SCSI Adapter Card 90 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 91
are subject to change) that may be supplied with the HP Kayak XM600 Desktop and Minitower PC Workstations (type and quantity depends on model) on internal shelves, connected to the SCSI or IDE controller. Quantum Atlas IV SCSI (7.2 krpm) Capacity 9.1 GB Interface Ultra2 Wide SCSI External peak - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 92
Single Word DMA Mode 2 - 8.3 Mbytes/s maximum Multi Word DMA Mode 2 - 16.6 Mbytes/s maximum 128 Kbytes Average Stroke (1 / 3) 110 ms Full Stroke 180 ms 2,048 bytes (Mode-1) 2,336 bytes (Mode-2) ATAPI 5V, 1.2A 12V, 0.8A 1. Refer to the HP Kayak PC Workstations Service Handbook to find out which - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 93
Single Word DMA Mode 2 - 8.3 Mbytes/s maximum Multi Word DMA Mode 2 - 16.6 Mbytes/s maximum 128 Kbytes Average Stroke (1 / 3) 110 ms Full Stroke 180 ms 2,048 bytes (Mode-1) 2,336 bytes (Mode-2) ATAPI 5V, 1.2A 12V, 0.8A 1. Refer to the HP Kayak PC Workstations Service Handbook to find out which - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 94
have a CD-RW (ReWritable) drive supplied in a 5.25-inch front-access shelf ATAPI, supporting ATAPI commands and with audio playback capability. Power Control to dynamically adjust laser writer power Red, Yellow, Orange, Green books 150,000 hours ATAPI 1. Refer to the HP Kayak PC Workstations Service - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 95
Setup program and BIOS of the HP Kayak XM600 PC Workstation. The POST routines are described in the next chapter. The BIOS is based on the core Phoenix BIOS, which includes 4 M/bits of flash memory, support for PCI 2.2 Specification, suspend to RAM, and RIMM or DIMM memory modules. The BIOS includes - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 96
5 HP BIOS Using the HP Setup Program To run the Setup program, press while the initial "Kayak" logo is displayed, immediately after restarting the PC Workstation. Alternatively, press to view the summary configuration screen. By default, this remains on the screen for 15 seconds, but pressing any - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 97
same structure as the Main Screen and Power Screen. Instead of presenting a list of fields, it offers a list of sub-menus. The Advanced screen is to be used by advanced users who wish to carry out special system configurations. Main Advanced >> Processors, Memory and Cache >> Floppy Disk Drives - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 98
5 HP BIOS IDE Devices Advanced IDE Devices >> IDE Primary Master Device >> IDE Primary Slave Device >> IDE Port [Auto] Parallel Port Mode [ECP] Serial Port A [Auto] Serial Port B [Auto] 98 Item-Specific Help Item-Specific Help Item-Specific Help Item-Specific Help Item-Specific Help - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 99
HP BIOS AGP Configuration (Video) Advanced AGP Configuration (Video) Graphic Aperture [64 MB Item-Specific Help PCI Device, Slot #1 Advanced PCI Device, Slot 11 Item-Specific characteristics and values of the System Administrator Password, User Password, Power-on Password, boot device security - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 100
Drives > Removable Devices Power Screen This screen allows you to set the standby delay and suspend delay. Standby mode slows down the processor, while the suspend mode saves a maximum of energy. Both these options are only available with Windows 95 RTM. For other operating systems, Windows 95 SR - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 101
5 HP BIOS Updating the System BIOS Updating the System BIOS The latest system BIOS (standard flash operation) can be downloaded from HP's Support Web site at: www.hp.com/go/kayaksupport. Then select HP Kayak XM600 PC Workstation. Instructions on updating the BIOS are supplied with the downloaded - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 102
cables, then remove the cover. 2 Set the system board switch 8 to the ON position to clear the CMOS memory. 3 Replace the cover, and only reconnect the power cord. 4 Reboot the PC Workstation. A message similar to the following will be displayed: "Configuration has been cleared, set switch Clear to - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 103
on the PC Workstation. 10 The PC Workstation boots from the floppy disk, then flashes the BIOS. However, it should be noted, that during the flash process, the screen remains blank. 11 The recovery process is finished when there is one very long beep. 12 Power off the PC Workstation. Remove the - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 104
HP BIOS , pressing during the POST (after the memory test) lets you recover and configure settings SCAM Support Off LSI Logic BIOS version 4.x and above supports SCSI Scan Order Low to High (0-Max) Informs the host adapter BIOS and device drivers to scan the SCSI bus from low (0 to max) - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 105
5 HP BIOS LSI MB/sec, 40 MB/sec, or 80 MB/sec. Data Width 16 Sets the maximum SCSI data width at which a 16-bit host adapter negotiates. The host adapter and Configuration Utility... is displayed during the PC Workstation's start-up routine. A further message is then displayed: Please wait, - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 106
the main features of the HP system BIOS. This is software that provides an interface between the computer hardware and the operating system.The procedure for updating the System ROM firmware is described on page 101. System Memory Map Reserved memory used by accessory boards must be located in the - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 107
system I/O space, which is not located in system memory space. The 64 KB of addressable I/O space comprises 8-bit and 16-bit registers (called I/O ports) located in the various system components. When installing an accessory board controller DMA controller 2 Co-processor error Free (IDE secondary - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 108
configuration space Power Management I/O space and ACPI Registers MBus I/O space DMA Channel Controllers Only "I/O-to-memory" and "memory-to-I/O" transfers are allowed. "I/O-to-I/O" and "memory-to-memory" transfers are disallowed by the hardware configuration. The system controller supports seven - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 109
5 HP BIOS BIOS Addresses Interrupt Controllers The system has an Interrupt controller which is equivalent in PCI devices Available for PCI devices Available for PCI devices Super I/O - Mouse Co-processor ICH - Integrated IDE Controller (primary) ICH - Integrated IDE Controller (secondary). 109 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 110
5 HP BIOS BIOS Addresses There are three major interrupt modes available: PIC mode: This "Legacy" mode uses only the interrupt controllers. Therefore, only one processor can be supported in this mode. This mode can be selected upon installation of Windows NT. Virtual wire mode: This mode is - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 111
, on the HP Kayak XM600 Minitower PC Workstation, error messages are displayed on the MaxiLife LCD status panel. All LCD status panel messages shown in this refer to the Minitower platform only. When the PC Workstation is turned on (pressing the ON/OFF button), the system initiates the normal - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 112
supply, CPU Board PLL and memory. Simply by having a power cord connected to the PC Workstation activates the Basic Pre-boot Diagnostics. The pre-boot diagnostic tests are run in order of priority with respect to their importance to computer functions. On the HP Kayak XM 600 Minitower PC Workstation - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 113
for any error messages that the BIOS may issue. If such an error occurs, then an error code is displayed on the monitor screen. On the HP Kayak XM 600 Minitower PC Workstation, a screen similar to the following example is displayed. The error code that appears on the LCD status panel is the same as - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 114
end of the POST. Operating System Boot Phase If no error message has been displayed at this stage of the system startup by the BIOS, the operating system is launched. On the HP Kayak XM 600 Minitower PC Workstation, the LCD status panel will display the system platform and a "smiling icon." 114 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 115
board. POWER ERRORS Power supply unit, system board. BOARD PLL Processor(s), system board POWER 12V ERROR VCC CPU 1 ERROR VCC CPU 2 ERROR Power supply unit has failed. Try the following: 1 Replace the power supply unit with a known working one 2 If the problem persists, replace the system board - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 116
of processors and speed, size of memory for each socket. The following diagram shows how the System Info obtains its information. System Info strings in EEPROM MaxiLife HP KAYAK XM600 Write BIOS LCD Status Panel DMI Table Shows the Power-On-Self-Test (POST) codes during the system startup - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 117
, the "smiling icon" is shown on the LCD status panel. Processor HP KAYAK XM600 If the Processor has only been partly inserted in the processor slot, then the displayed message will indicate a CPU socket error. Processor ERROR CPU SOCKET The Processor has not been inserted correctly in the - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 118
for a brief summary). Devices such as memory and newly installed hard disks, are configured automatically. The user is not requested to confirm the change. During the POST, the BIOS and other ROM data are copied into high-speed shadow RAM. The shadow RAM is addressed at the same physical location - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 119
Tests and Error Messages Order in Which POST Tests Are Performed Checkpoint Code Beeps POST Routine Description 02h Verify Real Mode 03h Disable Non-Maskable Interrupt (NMI) 04h Get CPU type 06h Initialize system hardware 08h Initialize chipset with initial POST values 09h Set IN POST - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 120
Checkpoint Code Beeps POST Routine Description 28h 1-3-3-1 Autosize DRAM 29h Initialize POST Memory Manager 2Ah Clear 512 KB base RAM 2Ch 1-3-4-1 RAM failure on address line 1 2Eh 1-3-4-3 RAM failure on data bits xxxx1 of low byte of memory bus 2Fh Enable cache before system BIOS - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 121
POST display service Display prompt "Press F2 to enter SETUP" Disable CPU cache Test RAM between 512 and 640 KB Test extended memory Test extended memory address lines Jump to UserPatch1 Configure advanced cache registers Initialize Multi Processor APIC Enable external and CPU caches Setup System - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 122
boards Install CD ROM for boot Clear huge ES segment register Fix up Multi Processor table 1-2 Search for option ROMs. One long, two short beeps on checksum failure. Check for SMART drive Shadow option ROMs Set up Power Management Initialize security engine (optional) Enable hardware interrupts - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 123
6 Tests and Error Messages Order in Which POST Tests Are Performed Checkpoint Code 9Fh A0h A2h A4h A8h AAh ACh AEh B0h B2h B5H B6h B7h B8h B9h BAh BBh BCh BDh BEh BFh C0h C1h C2h C3h Beeps POST Routine Description Determine number of ATA and SCSI drives Set time of day - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 124
in Flash ROM Initialize the chipset Initialize the bridge Initialize the CPU Initialize system timer Initialize system I/O Check force recovery boot Checksum BIOS ROM Go to BIOS Set Huge Segment Initialize Multi Processor Initialize OEM special code Initialize PIC and DMA Initialize Memory type - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 125
System Management Mode F4h 1 Output one beep before boot F5h Boot to Mini DOS F6h Clear Huge Segment F7h Boot to Full DOS 1. If the BIOS detects error 2C, 2E, or 30 (base 512K RAM error), it displays BIOS also sends the bitmap to the port-80 LED display. It first displays the checkpoint code - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 126
error generated in POST (Power-On-Self-Test) during the boot process, there are two beeps, then the Error Setup Manager gives access to one or more detected errors. Each EMU error is displayed as a 4digit code with an associated text message on the monitor screen and the MaxiLife LCD panel. If the - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 127
Messages Error Message Summary Code # Cause / Symptom CPU Termination Card missing from Processor 2 socket in a mono-processor system Keyboard stuck key Keyboard self Number Invalid Internal product type Fan Not Connected Remote Power On Error CPU Terminator Card Error Keyboard Error Keyboard - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 128
Tests and Error Messages Error Message Summary Code # Cause / Symptom 0400h 0401h 0500h 0501h Error Video Memory Error System Memory Error System Memory Error System Memory Error System Memory Error System Memory Error System Memory Error System Memory Error System Cache Error System Cache Error - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 129
protection. CMOS contents have changed between 2 power-on sessions. Run Setup for configuration. Check that the main memory modules are correctly set in their sockets. An error message may be displayed and the computer may "hang" for 20 seconds and then beep. The POST is probably checking for a mass - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 130
is unable to display the error message. Beep Pattern Beep Numeric Code Code Description Recommended Action 1-2-2-3 16h BIOS ROM check-sum failure Inform HP support/HP reseller that system board is defective. - - - - - - 1-3-1-1 20h DRAM refresh test failure1 Check the memory is correctly - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 131
7 Connectors and Sockets IDE Drive Connectors Battery Pinouts IDE Connectors Pin Signal Pin Signal 1 Reset# 3 HD7 5 HD6 7 HD5 9 HD4 11 HD3 13 HD2 15 HD1 17 HD0 19 Ground 7 21 DMARQ 23 DIOW# 25 DIOR# 27 IORDY 29 DMACK# 31 INTRQ 33 DA1 35 DA0 37 CS1FX# 39 DASP# 2 Ground 4 HD8 6 HD9 8 HD10 10 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 132
Additional SCSI LED Connector (4-pin) Pin Signal 1 Not used 2 LED Out 3 LED Out 4 Not used Power Supply Connector (20-pin) and Aux Power Connector Power Supply Connector for System Board (20-pin) Pin Signal Pin Signal 11 3V3_MAINSENSE 1 3V3_2 12 12V_NEG 2 3V3_3 13 GROUND_1 3 GROUND2 14 - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 133
7 Connectors and Sockets PCI Fan Connector (MT only) Internal Audio Connectors Status Panel and Intrusion 321 Vertical plastic latch for keying and attachment Fan Connector Pin Signal 1 Sense 2 +12 V Power (or less, depending on desired fan speed) 3 Ground CD AUDIO Connector Pin Signal I/O - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 134
BLUE Monitor ID2 DDC return Analog RED Analog GREEN Analog BLUE VCC supply (optional) Digital ground Monitor ID 0 Data:SDA HSYNC VSYNC Clock:SCL LCD Panel Pin Signal 1 SCL_5V 3 SDA_5V 5 not connected 7 RX_BB 9 Ground LCD Panel Pin Signal 2 VSTDBY 5V 4 BT_LCD 1 6 BT_LCD 2 8 TX_BB 10 Ground - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 135
7 Connectors and Sockets Rear Panel Socket Pin Layouts Rear Panel Socket Pin Layouts Keyboard Connector USB Connectors (two) 9-pin Serial Port Connectors Serial Port A Serial Port B Audio jacks Line Out Line In MIC Mouse Connector 25-pin Parallel Port Connector MIDI/Joystick Connector - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 136
table below are for one connector, the (top - MT, Left - DT) information is valid for both the Serial Port A and Serial Port B Connectors. and Serial Port B (bottom - MT, Right - DT) Connectors 1 6 2 7 3 8 4 9 5 9-pin Serial Port Connector Pin Signal - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 137
Signal Pin Signal 9 +5 V 10 B-1 11 B-X 12 MIDI-OUT 13 B-Y 14 B-2 15 MIDI-IN 8 +5 V 7 A-2 6 A-Y 5 Ground 4 Ground 3 A-X 2 A-1 1 +5 V External Audio Jacks On the PC Workstation there is a Line In jack, Line Out jack and Mic In jack located on the rear panel. These external jacks are standard - HP XM600 | hp kayak xm600 series 1, technical reference manual for desktop and m - Page 138
7 Connectors and Sockets Rear Panel Socket Pin Layouts 138
HP Kayak XM600 PC Workstation
Technical Reference Manual