    VSXGVDUHVHFXUHO\ screwed into the gas supply tubes. ( ,QVWDOOWKHROGRUL¿FHVSXGVLQWRWKHPHWDOER[RUEUDFNHW along with these instructions, and replace onto the back of the UDQJHIRUSRVVLEOHIXWXUHFRQYHUVLRQ 95 Denotes 0.95mm Orifice size opening Denotes LP (Propane) III  7XUQ
  • Hotpoint RGBS300DMBB | LP Conversion Kit - Page 2
    the air shutter screws.  E5HSODFHWKHRYHQERWWRP SPECIAL NOTE: To convert the oven back to natural gas, reverse the instructions given in making propane (LP) adjustments. PROPANE (LP) CONVERSION INSTRUCTIONS 31-11148-2 01-20 GEA JGBS10, JGBS30, JGBS61, RGBS300, RGBS400, JGBS60 and XGBS400
  • 1
  • 2

BURNER OUTPUT RATINGS: BTU/HR
Propane (LP) Gas 10” W.C.P.
BURNER
BTU
RATE
ORIFICE
SIZE (mm)
COLOR
MARKING
RF
12,000
0.039” (0.99)
Blue/Magenta
99L
LF
9,500
0.035” (0.89)
Blue/Brown
89L
RR
5,000
0.026” (0.66)
Red/Yellow
66L
LR
9,500
0.035” (0.89)
Blue/Brown
89L
OVEN
16,000
0.048” (1.21)
Pink
0.048
To adjust your range for use with propane (LP) gas, follow
these instructions:
1. Disconnect all electrical power, at the main circuit breaker or
fuse box.
CONVERTING THE PRESSURE REGULATOR
CONVERTING THE COOKTOP BURNERS
opening in the base.
To aid in identifying the proper location for the propane (LP)
The pressure regulator is located on the rear of the range.
1.
Use an adjustable wrench to unscrew the hex-nut cap from
the pressure regulator.
threaded metal cap.
4.
Screw the hex-nut cap back into the regulator.
(Do not over tighten)
TOOLS REQUIRED:
• Adjustable wrench
• 1/2” Open-end wrench
(blade approximately
3/32” across)
or 7mm
Pressure Regulator
PROPANE (LP) CONVERSION INSTRUCTIONS
PROPANE
NAT
Rotate cap counter-
clockwise to loosen
Cap assembly
WARNING
Explosion Hazard
Death or serious injury can result from failure to follow
these instructions.
• Replace all parts and panels before operating.
NOTICE:
adjustments described in the following steps must be
made before you make any burner adjustments.
NOTICE:
WARNING
burners of this range when using propane (LP) (bottled) gas
for propane (LP) gas use. Failure to do so could cause high
natural gas. To use propane (LP) gas, the regulator and burner
screwed into the gas supply tubes.
along with these instructions, and replace onto the back of the
95
III
Denotes 0.95mm Orifice size opening
Denotes LP (Propane)
Burner
cap
Burner construction
Burner
head
Base
Orifice
located
through this
opening
LR
RR
LF
RF
Blue/Magenta
Propane
Blue/Brown
Propane
Blue/Brown
Propane
Red/Yellow
Propane
PROPANE (LP) CONVERSION INSTRUCTIONS
31-11148-2
01-20
GEA
JGBS10, JGBS30, JGBS61, RGBS300, RGBS400, JGBS60 and XGBS400
the back of the range in the location shown.