Hunter 44550 Owner's Manual

Hunter 44550 Manual

Hunter 44550 manual content summary:

  • Hunter 44550 | Owner's Manual - Page 1
    SINCE ® 1 8 8 6 AUTO SAVER 550 5:22 3 72 OwnerÕs Manual Model 44550
  • Hunter 44550 | Owner's Manual - Page 2
    Ask Your Local Retailer for Other Quality Products from Hunter Fans Air Purifiers Humidifiers To locate your nearest Hunter Dealer, call 1-800-4HUNTER, or visit The Hunter Fan Company website: www.hunterfan.com
  • Hunter 44550 | Owner's Manual - Page 3
    service. By saving energy, your thermostat will pay for itself during its first season of use. Thank you for buying a Hunter product! Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, call Hunter Technical Support
  • Hunter 44550 | Owner's Manual - Page 4
    What You Need Remove Old Thermostat Wire Labeling Mount Wallplate and Thermostat Selector Switches Setting Time and Day Auto Programming Personal Program Schedule Manual Programming Weekday / Weekend Programming 7-Day Programming Reviewing Programs Reviewing the Current Temperature Setting System
  • Hunter 44550 | Owner's Manual - Page 5
    Filter Monitor 29 Auto Recovery 30 Keyboard Lock 31 Backlighting 31 SAFETY FEATURES Low Battery Warning 32 Error Mode 33 Auto Cut-Off 33 TROUBLESHOOTING Problems & Solutions 34 Technical Support 35 WIRING DIAGRAMS Heat / Cool Systems 36 Single-Stage Heat Pump Systems 37 Heat
  • Hunter 44550 | Owner's Manual - Page 6
    Manual Override. See page 25 for more information. Press Auto Program to load the built-in energy saving programs. OPERATION 4 Your Thermostat is designed to operate with most gas, oil, electric or 2-wire hot water heating and air conditioning systems. It will also operate single-stage heat pumps
  • Hunter 44550 | Owner's Manual - Page 7
    or fails, the battery power retains the programs and current time. AUTO RECOVERY 8 Your thermostat is set from the factory to gradually recover the room temperature from an energy saving program to your comfort program. Therefore, the thermostat may turn your system on several minutes prior
  • Hunter 44550 | Owner's Manual - Page 8
    M Usage Today Yesterday This Week Last WeekTotal COOL OFF HEAT AUTO FAN ON AUTO Temperature Keys: Keys for raising or lowering temperature settings. Battery Door: Frontaccess battery door allows easy battery changes. Soft-touch programming keypad, see details below. Fan Switch: Fan switch for
  • Hunter 44550 | Owner's Manual - Page 9
    to current program control from manual override or Home Today mode. Reviews filter usage in hours and minutes. Also resets filter counter to zero. Returns display to current time and temperature. As an ENERGY STAR® Partner, Hunter Fan Company has determined that this programmable thermostat meets
  • Hunter 44550 | Owner's Manual - Page 10
    before reading the instructions carefully. WIRES MUST BE LABELED PRIOR TO REMOVAL. s IMPORTANT! Turn off the power to the furnace at the main power panel or at the furnace. s Remove existing thermostat cover. See Figure 1. Some thermostats will have screws or other locking devices that must
  • Hunter 44550 | Owner's Manual - Page 11
    Y/Y1 not always comply with the standard. W RH s After labeling wires, disconnect them from the existing thermostat terminals. s Remove existing wallplate. To make sure RC W or H Heating Not for heat pumps W Y/Y1 Y/Y1 W W wires do not fall back into wall opening, you may want to tape
  • Hunter 44550 | Owner's Manual - Page 12
    tab on the bottom of the thermostat. (See Figure 2.) s Position wallplate on wall and pull existing wires through large opening. Then level for appearance. Mark holes for plastic anchors provided if your existing holes do not line up with those on the Hunter wallplate. s Drill holes with 3/16" bit
  • Hunter 44550 | Owner's Manual - Page 13
    operational problems with your system or thermostat. s Push excess wire back into hole to prevent interference with mounting of the thermostat cover. s Make sure the System Switch is set to OFF, and the FAN-AUTO Switch is in AUTO. s If your system has an O or B wire, you must move the Heat Pump
  • Hunter 44550 | Owner's Manual - Page 14
    Hunter thermostat to control your system, the system type must be specified by selector switches on the printed circuit board inside the thermostat heat pump system has a "B" wire, slide the switch to "B" for your reversing valve that activates in HEAT mode. If your heat pump system has an "O" wire,
  • Hunter 44550 | Owner's Manual - Page 15
    to the ALT position. This may be necessary if your heating system cycles too rapidly. s Auto Recovery selector - Switch 8 Your thermostat is set from the factory with the Auto Recovery Feature enabled, which complies with the EPA ENERGY STAR® Program. If you prefer to use normal recovery, slide the
  • Hunter 44550 | Owner's Manual - Page 16
    update after a few seconds. 72 AUTO COOL HEAT TEMP °HC EXAMPLE: Set the thermostat to the current time of 9:43 a.m. on Saturday. Refer to Figure at right. s During time and day setting mode, the temperature and program displays will go blank. HOUR s Press and hold to rapid advance to the
  • Hunter 44550 | Owner's Manual - Page 17
    to modify these programs than to program the thermostat manually. A U : T O AUTO s Press once. During Auto Programming, the display will change as shown. PROGRAM M T W Th F Sa Su SET TEMP AM °C PM H 88 AUTO COOL HEAT TEMP °HC s The thermostat will be programmed for all 7 days of the week
  • Hunter 44550 | Owner's Manual - Page 18
    and temperature settings change your temperature settings. will best satisfy both your comfort and energy saving requirements. Heating Cooling Day Program 1 Program 2 Program 3 Program 4 Program 1 Program 2 Program 3 Program 4 Mon. Time Temp Tues. Time Temp Wed. Time Temp Thurs. Time Temp Fri
  • Hunter 44550 | Owner's Manual - Page 19
    first installed, the thermostat has all 4 programs set for 68°F (20°C) in Heat mode and 78°F (26°C) in Cool mode. NOTE: There are no energy saving time or temperature settings until the thermostat is Auto Programmed or Manually Programmed. s Familiarize yourself with Manual Programming, so that you
  • Hunter 44550 | Owner's Manual - Page 20
    to change to weekend programs. PROG DAY s Repeat Steps 3 and 4 to complete the weekend programs. RETURN s If you desire only weekend and weekday programs, press to return to normal mode. s After 15 seconds, the thermostat will return to normal mode automatically. COOL OFF HEAT AUTO s Change the
  • Hunter 44550 | Owner's Manual - Page 21
    Continue repeating Steps 3, 4 and 5 to program all 7 days of the week. s When finished press to return to normal mode. RETURN s After 15 seconds, the thermostat will return to normal mode automatically. Step 3 8 7 : 3 0 M T W Th F Sa Su SET TEMP AM °C PM H 70 AUTO COOL HEAT TEMP °HC Step
  • Hunter 44550 | Owner's Manual - Page 22
    PROGRAMMING 7-Day Programming (cont.) Step 7 COOL OFF HEAT AUTO s Change the System Selector Switch to the other system, and repeat Steps 2 through 6 above. 22-23 Reviewing Programs You may want to review the programs to confirm that the settings are compatible with your lifestyle. Weekday
  • Hunter 44550 | Owner's Manual - Page 23
    AM °C PM H 79 AUTO COOL HEAT TEMP °HC NOTE: Programs take affect as soon as the thermostat returns to normal mode. If you are armchair programming the thermostat, slide the system selector to the OFF position before mounting the thermostat to the wallplate. Reviewing the Current Temperature
  • Hunter 44550 | Owner's Manual - Page 24
    air conditioning, and heat pump operation, the Fan will turn on with the system. To run the Fan continuously, slide the Fan switch to the ON position. Temporary Manual Override ON AUTO To temporarily change the current set temperature without affecting your program: Press and hold Press and or
  • Hunter 44550 | Owner's Manual - Page 25
    F Sa Su SET TEMP AM °C PM H 73 AUTO COOL HEAT TEMP °HC To end the Permanent Manual Override: s Press again. The thermostat will return to the current program, and the HOLD CLEAR flashing HOLD display will be canceled. NOTE: The Auto Season Changeover feature will not operate while the
  • Hunter 44550 | Owner's Manual - Page 26
    the air conditioner. Likewise, the thermostat will automatically change to heat mode and turn on heat when the room temperature falls below 68°F. This Hunter patent pending feature allows you to quickly and temporarily override your energy saving program setting on days when you are normally away
  • Hunter 44550 | Owner's Manual - Page 27
    is already active, you may similarly extend it to the first program of the next day by pressing the key again after the start time of the third program. s If the system is changed between Heat and Cool modes (either manually or by Auto Season Changeover) during the "Home Today" override period, the
  • Hunter 44550 | Owner's Manual - Page 28
    amount of time the heating and air conditioning system saving and you can test program adjustment to save even more. Use table on page 18. ENERGY s To review 26 Usage Today TEMP °MC ENERGY s Press and hold for 3 seconds to reset the Energy Monitor's counters. The display will blink,
  • Hunter 44550 | Owner's Manual - Page 29
    AM °C PM H s Press to review total filter usage. The display will blink "FILT," then show the Filter Monitor counter. After 15 seconds, the To reset the Filter Monitor counter, depress FILTER for 3 seconds. The display will blink, and the counter will be reset to zero. 70 AUTO COOL HEAT TEMP
  • Hunter 44550 | Owner's Manual - Page 30
    temperature at 6am would be about 68°F instead of 60°F. s When the thermostat is in Auto Recovery mode, the display will alternate "RECV" with time, and the program indicator will flash. R E : C V M T W Th F Sa Su SET TEMP AM °C PM H 74 AUTO COOL HEAT TEMP °HC . 70 30-31 Details of
  • Hunter 44550 | Owner's Manual - Page 31
    for the LIGHT bar. Any time a key is pressed, LOCK will appear on the display for 1 second. L O : C K M T W Th F Sa Su SET TEMP AM °C PM H 74 AUTO COOL HEAT TEMP °HC Backlighting (INDIGLO® night-light) Your thermostat has an electroluminescent lamp that backlights the display for easy
  • Hunter 44550 | Owner's Manual - Page 32
    Th F Sa Su SET TEMP AM °C PM H 74 AUTO COOL HEAT TEMP °HC NOTE: The backlight will not operate in low thermostat will turn your system Off. Your system will remain shut-off until the batteries are replaced. B A:T T NOTE: The thermostat will still keep the current time and your programs
  • Hunter 44550 | Owner's Manual - Page 33
    press the RESET button next to the keypad. You will need to reprogram your thermostat and confirm normal operation. If Error Mode returns, please call Hunter Technical support at (901) 745-9222 for further information. E R R-- Auto Cut-Off Your thermostat will automatically cut-off in Heat mode if
  • Hunter 44550 | Owner's Manual - Page 34
    for the correct day setting. 1. Move HG/HE selector to opposite position 1. Check that the system selector switch is in the correct position ("HEAT," "COOL" or "AUTO"). 2. The thermostat may be in the AUTO mode. Look for "AUTO" on the LCD display. If the Heat and Cool program temperatures are close
  • Hunter 44550 | Owner's Manual - Page 35
    a small pin and hold for two seconds. The thermostat will need to be reprogrammed. IF UNIT CONTINUES TO OPERATE IN THE OFF POSITION 1. Replace unit. THERMOSTAT PERMANENTLY READS "HI," "LO," OR "ERR-" AFTER PRESSING RESET BUTTON 1. Replace unit. If you experience any other problems, call 901-745
  • Hunter 44550 | Owner's Manual - Page 36
    WIRING DIAGRAMS 4-wire Heat/Cool System Jumper RC RH Heat/Cool 24V Supply THERMOSTAT G Fan Relay W Y O/B X Heat Relay or Valve Cool Contactor 5-wire Heat/Cool System THERMOSTAT RC RH G Cool Heat Fan 24V Supply 24V Supply Relay W Y O/B X Heat Relay Cool or Valve Contactor X
  • Hunter 44550 | Owner's Manual - Page 37
    Single-stage Heat Pump 2-wire Heat Only Jumper RC RH Heat Pump 24V Supply THERMOSTAT G W X Fan Relay Y O/B Compressor Reversing Contactor Valve THERMOSTAT RC RH G W Y O/B X X X X Heat 24V Supply Heat Relay or Valve X - No Connection
  • Hunter 44550 | Owner's Manual - Page 38
    WIRING DIAGRAMS 38 3-wire Heat Only Jumper THERMOSTAT RC RH G W Y O/B X X X Heat Fan 24V Supply Relay Heat Relay or Valve 3-wire Cool Only THERMOSTAT RC RH G X Cool Fan 24V Supply Relay W Y O/B X X Cool Contactor X - No Connection
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

Owner°s Manual
Model 44550
SINCE
1 8 8 6
®
AUTO SAVER 550
5:
7
2
2
2
3