IBM 10000XHV Operating Guide

IBM 10000XHV - UPS - Lead Acid Manual

IBM 10000XHV manual content summary:

  • IBM 10000XHV | Operating Guide - Page 1
    IBM UPS 7500XHV IBM UPS 10000XHV Uninterruptible Power Supply Operation and Setup Guide 25R5636
  • IBM 10000XHV | Operating Guide - Page 2
  • IBM 10000XHV | Operating Guide - Page 3
    Part Numbers...17 6: TROUBLESHOOTING...18 7: GETTING HELP AND TECHNICAL ASSISTANCE...20 Before you call ...20 Using the Documentation...20 Getting help and information from the World Wide Web ...20 Software service and support...20 Hardware service and support...20 Replacement part handling ...21
  • IBM 10000XHV | Operating Guide - Page 4
  • IBM 10000XHV | Operating Guide - Page 5
    de veiligheidsvoorschriften. Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information. Avant d'installer ce produit, lisez les consignes de sécurité. Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni
  • IBM 10000XHV | Operating Guide - Page 6
    Antes de instalar este produto, leia as Informações sobre Segurança. Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten. WARNING: Handling the cord on this product or cords associated with accessories sold with this
  • IBM 10000XHV | Operating Guide - Page 7
    instructed otherwise in the installation and Guide). Push the ON button to de-energize the capacitors. CAUTION! Battery Safety • This equipment contains potentially hazardous voltages. Refer to your product documentation to determine which parts are user-replaceable. • Do not dispose of batteries
  • IBM 10000XHV | Operating Guide - Page 8
    front bezels " Rail kit " Tower conversion kit " Accessory kit containing: " Quick Installation Guide " Documentation CD " PowerChute® Business Edition CD " Network Management Card CD " Warranty Flyer " Rack-mounting brackets " Temperature probe " Serial communication cable - 4.6 m (15 ft) " Serial
  • IBM 10000XHV | Operating Guide - Page 9
    without the battery modules. Select a location sturdy enough to handle the weight. Do not by a qualified electrician. 1. Install a utility circuit breaker according to and . Wire to L1A, N1, and . System UPS 7500XHV UPS 10000XHV Wiring Voltage Input Output Input 200/208 V 200/208 V 200/208
  • IBM 10000XHV | Operating Guide - Page 10
    . Referencing the chart below, install the cage nuts (or clip nuts). The solid squares indicate the cage nut or clip nut location. Mount the uninterruptible power supply at the bottom of the rack. Note: Leave 3 U of space below the uninterruptible power supply for each battery pack that you plan to
  • IBM 10000XHV | Operating Guide - Page 11
    # Secure the uninterruptible power supply in the rack. $ Attach the front bezel. Installing and Connecting the Batteries and Attaching the Front Battery Bezel ! Install all battery modules. " Connect the batteries. # Reinstall and secure the battery doors with the captive screws. Make sure the
  • IBM 10000XHV | Operating Guide - Page 12
    to a tower configuration, remove the battery modules (see Removing the Battery Modules). ! Remove the rail guides. " Bring the unit to tower position, and remove the display bezel by sliding to the left and out. Rotate the display bezel and reinstall. Install the first battery module at the bottom
  • IBM 10000XHV | Operating Guide - Page 13
    used with the uninterruptible power supply. Use only cables supplied or approved by IBM. Note: Use the supplied serial cable to connect to the serial port. . Optional battery packs provide extended runtime during power outages. See 3U Extend Run Battery Pack Operation and Setup Guide. Provides access
  • IBM 10000XHV | Operating Guide - Page 14
    Start=> Settings=> Control Panel=> Administrative Tools=> Services. b. Select PCBE Server and PCBE Agent; name and select an icon. Disregard the message, must install a modem, if it is dis- played. Click OK . Network Management Card defaults: • User Name: apc • Password: apc b. Press 1 and Enter to
  • IBM 10000XHV | Operating Guide - Page 15
    user-initiated command (performed manually through the manual bypass switch). Battery operation is not available while the uninterruptible power supply is in bypass mode. See Troubleshooting equipment on battery. If the uninterruptible power supply fails the self-test, the replace battery LED is
  • IBM 10000XHV | Operating Guide - Page 16
    the utility voltage bar graph display. After a few seconds, this five-LED Battery Charge show the utility input voltage. display on the right of the front panel supply continues to supply power to the connected equipment until the battery is fully discharged. If you are not using PowerChute, shut
  • IBM 10000XHV | Operating Guide - Page 17
    UPS 7500XHV Model: UPS 10000XHV Model: Load (W) 50 100 200 300 400 500 600 700 800 900 1000 4.16 3.16 2.55 2.11 1.80 1.56 1.38 1.23 1.16 55 47 41 36 32 24 19 17 13 10 7 5 4 3 Number of Battery Packs +1 13.83 10.93 7.65 5.83 4.68 3.91 3.33 2.90 2.56 2.30 2.08 1.73 1.50 1.28 1.13 1.00 48 39 34 28
  • IBM 10000XHV | Operating Guide - Page 18
    MODE. REFER TO THE SOFTWARE HELP GUIDES FOR DETAILS. FUNCTION FACTORY DEFAULT USER SELECTABLE CHOICES DESCRIPTION Automatic Self-Test purposes. Date of Last Battery Manufacture Date mm/dd/yy Replacement Reset this date when you replace the battery modules. Minimum Capacity Before Return
  • IBM 10000XHV | Operating Guide - Page 19
    Battery 1 Packs Number of Connected Battery Packs (four battery modules per pack) The user can define the number of connected battery packs use in raceways • For installation in Canada: Use only CSA certified, type ELC (extra-low voltage control cable) • For installation in other countries: Use a
  • IBM 10000XHV | Operating Guide - Page 20
    on for the replacement procedure. Contact your IBM marketing representative or authorized reseller for information about replacement battery modules. Refer to Removing the Battery Modules for removal instructions. For battery replacement, see Installing and Connecting the Batteries and Attaching the
  • IBM 10000XHV | Operating Guide - Page 21
    ) availability for the UPS 7500XHV and UPS 10000XHV models. Customer Replaceable Unit Part Numbers IBM CRU part numbers are subject to change without notice. This section contains a listing of the CRU part numbers available at the time this document was published. INDEX 1 2 3 4 5 6 7 8 9 10 11 CRU
  • IBM 10000XHV | Operating Guide - Page 22
    6: TROUBLESHOOTING Use the chart below to solve minor uninterruptible power supply installation and operation problems. Refer to IBM for assistance with complex uninterruptible power supply problems. PROBLEM AND POSSIBLE CAUSE SOLUTION UNINTERRUPTIBLE POWER SUPPLY WILL NOT TURN ON The
  • IBM 10000XHV | Operating Guide - Page 23
    has been turned on manually. If bypass is the serviced immediately. REPLACE BATTERY LED IS LIT The replace battery LED problem persists after recharging, replace the battery. A battery self-test has failed. The uninterruptible power supply emits short beeps for one minute and the replace battery
  • IBM 10000XHV | Operating Guide - Page 24
    documentation, and use diagnostic tools that come with your system. • Go to the IBM Support Web site at http://www.ibm.com/pc/support/ to check for technical informa- tion, hints, tips, and new device drivers. You can solve many problems without outside assistance by following the troubleshooting
  • IBM 10000XHV | Operating Guide - Page 25
    to ship back to IBM. Pack the uninterruptible power supply properly to avoid damage in transit. Never use Styrofoam beads for packaging. Damage sustained in transit is not covered under warranty. Attention: Always disconnect the battery before shipping. The battery can remain in the uninterruptible
  • IBM 10000XHV | Operating Guide - Page 26
    instead. However, it is the user's responsibility to evaluate and verify the operation of any non- IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license
  • IBM 10000XHV | Operating Guide - Page 27
    http://www.ibm.com/ibm/environment/products/prp.shtml. Battery return program This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride, lithium, or lithium ion battery. Consult your user manual or service manual for specific battery information. The battery must be recycled
  • IBM 10000XHV | Operating Guide - Page 28
    not installed and used in accordance with the instruction manual, may Canada. Australia and New Zealand Class A statement Attention: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user the fitting of non-IBM option cards. This product
  • IBM 10000XHV | Operating Guide - Page 29
    Taiwan electronic emission statement Note: For the purpose of BSMI certification clarity, IBM UPS 7500XHV, 2130-6RX, and 25R5583 are identical, and IBM UPS 10000XHV, 2130-8RX and 25R5584 are identical. Chinese Class A warning statement Statement of Conformity to the Voluntary Control Council for
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

IBM UPS 7500XHV
IBM UPS 10000XHV
Uninterruptible Power Supply
Operation and Setup Guide
25R5636