IBM 21302RX Installation Guide

IBM 21302RX Manual

IBM 21302RX manual content summary:

  • IBM 21302RX | Installation Guide - Page 1
    UPS3000 LV and UPS3000 HV Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 2
  • IBM 21302RX | Installation Guide - Page 3
    UPS3000 LV and UPS3000 HV Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 4
    Before using this information and the product it supports, read the general information in Appendix B, "IBM Statement of Limited Warranty Z125-4753-08 04/2004," on page 45 and Appendix C, "Notices," on page 63. Third Edition (July 2008) © Copyright International Business Machines Corporation 2006,
  • IBM 21302RX | Installation Guide - Page 5
    , leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. © Copyright IBM Corp. 2006, 2008 iii
  • IBM 21302RX | Installation Guide - Page 6
    safety information that comes with the server or optional device before you install the device. iv UPS 3000 LV and UPS3000 HV: Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 7
    provided power cord for any other product. v Do not open or service any power supply assembly. v Do not connect or disconnect any cables or all cables from the devices. To connect: 1. Turn off everything (unless instructed otherwise). 2. Attach all cables to the devices. 3. Attach the signal cables
  • IBM 21302RX | Installation Guide - Page 8
    as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call. (C004) CAUTION: >32 kg (70.5 lb) or or 32-55 kg (70.5-121.2 lb) The weight
  • IBM 21302RX | Installation Guide - Page 9
    might have more than one power cord. Be sure to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing. v Connect all devices installed in a rack cabinet to power devices installed in the same rack cabinet. Do not plug a power cord from a device installed
  • IBM 21302RX | Installation Guide - Page 10
    unstable if you pull out more than one drawer at a time. v (For fixed drawers) This drawer is a fixed drawer and must not be moved for servicing unless specified by the manufacturer. Attempting to move the drawer partially or completely out of the rack might cause the rack to become unstable or
  • IBM 21302RX | Installation Guide - Page 11
    27 Before you begin 27 Connecting the card to a terminal or computer 28 Configuring the Web/SNMP card 28 Set the IP address, gateway address, and MIB system group 29 Set Web/SNMP card control group 30 Set write access managers 30 Set trap receivers 30 © Copyright IBM Corp. 2006, 2008 ix
  • IBM 21302RX | Installation Guide - Page 12
    the electronics module (for trained service technician only) . . . . . 36 Replacing the battery module (for trained service technicians only 37 Chapter 6. Troubleshooting 39 Audible alarms and uninterruptible power supply conditions 39 Troubleshooting guide 39 Appendix A. Getting help and
  • IBM 21302RX | Installation Guide - Page 13
    uninterruptible power supply comes with a limited warranty. See Appendix B, "IBM Statement of Limited Warranty Z125-4753-08 04/2004," on page 45. See the Rack Installation Instructions document for complete rack installation and removal instructions. Note: The illustrations in this document might
  • IBM 21302RX | Installation Guide - Page 14
    Adobe Acrobat Reader or xpdf. The Documentation Browser automatically detects the regional settings in use in your computer and displays the documents in the language for that region (if available). If a document is Browser. 2 UPS 3000 LV and UPS3000 HV: Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 15
    25 mm (0.98 in.) for circuit breakers 3 mm (0.12 in.) for outlets Weight 37.0 kg (82.0 lb) 37.0 kg (82.0 lb) Operating temperature at 320 C20, connection to source using country specific power cords Power outlets One L5-30R dBA Battery mode
  • IBM 21302RX | Installation Guide - Page 16
    multilingual Safety Information document, which is on the IBM Documentation CD. Each statement is numbered for reference to problem situations. v Attention: These notices indicate potential damage to programs, devices, or data. An attention notice is placed just before the instruction Guide
  • IBM 21302RX | Installation Guide - Page 17
    configuration v Connecting the internal battery v Connecting the UPS to (to remove the battery module [trained service technicians only]) v mounting pedestals v Documentation CD v Power-management software CD v Four 2 meter C13/C14 Instructions document that comes with the rail kit. © Copyright
  • IBM 21302RX | Installation Guide - Page 18
    instructions for setting up the uninterruptible power supply and optional extended battery modules in a tower configuration. CAUTION: >32 kg (70.5 lb) or or 32-55 kg (70.5-121.2 lb) The weight power supply (with no extended battery module)" on page 7). v For two chassis: Install two pedestals
  • IBM 21302RX | Installation Guide - Page 19
    module" on page 8 or "Setting up the uninterruptible power supply with two or more extended battery modules" on page 9. To set up the uninterruptible power supply in a tower configuration, complete the following steps: 1. Unscrew and remove the mounting brackets on each
  • IBM 21302RX | Installation Guide - Page 20
    an extended battery module in the extended battery module. edge of the chassis so that the weight of the unit is evenly distributed. Secure accessory kit. 4. Place the extended battery module chassis upside down so that edge of each chassis so that the weight of the unit is evenly distributed. Secure
  • IBM 21302RX | Installation Guide - Page 21
    with the adjacent corner screw holes in the uninterruptible power supply and extended battery module. Uninterruptible power supply Extended battery module bracket Extended battery module Top view Extended battery module bracket b. Secure the brackets with the screws that come with the extended
  • IBM 21302RX | Installation Guide - Page 22
    on the shipping carton label. If the expiration date has passed and the batteries were never recharged, do not use the uninterruptible power supply. Contact your service representative. v Connect the internal battery after you install the uninterruptible power supply in a rack cabinet or in a tower
  • IBM 21302RX | Installation Guide - Page 23
    a UPS3000 HV. See "Rear view" on page 18 for the rear view of the UPS3000 LV model. Note: You can connect up to four extended battery modules to the uninterruptible power supply. If there are two uninterruptible power supplies in a rack, you can connect up to two extended
  • IBM 21302RX | Installation Guide - Page 24
    modules are in the Off position. Web/SNMP card Input connector Power cord UPS battery Off 1 2 On connector Extended battery module connectors Extended battery module cable On Off Battery circuit breaker 2. Connect an extended battery module to the uninterruptible power supply, using an
  • IBM 21302RX | Installation Guide - Page 25
    battery module, connect one end of an extended battery module cable to the connector on the bottom of the second extended battery management software, connect a workstation or notebook computer to the uninterruptible power supply communication connector (the COM connector on the Web/SNMP card
  • IBM 21302RX | Installation Guide - Page 26
    that is initiated by any power-management software. Any devices that are operating on battery power are also shut down immediately. connected devices will not return to battery power until the uninterruptible power supply is restarted manually. If the off button is pressed and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 27
    2. If the remote emergency power-off connector is installed, disconnect it from the remote emergency power-off connector on the rear of the uninterruptible power supply. Remote emergency power-off connector Openings Remote emergency power-off port 3. Connect isolated, normally open, dry contacts (
  • IBM 21302RX | Installation Guide - Page 28
    16 UPS 3000 LV and UPS3000 HV: Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 29
    battery capacity is low. Battery service LED: When this LED is red and flashing, the battery is not connected correctly or the battery needs to be replaced. Site wiring fault LED: When this LED is red and flashing, there are problems power supply. © Copyright IBM Corp. 2006, 2008 17
  • IBM 21302RX | Installation Guide - Page 30
    card 5-15 receptacles Circuit breakers Off 1 2 On L5-30 receptacle Remote emergency power-off port Battery card 16A, IEC 320-C20 IEC 320-C13 input connector receptacles Off 1 2 On Circuit breakers Remote emergency power-off port Battery Alarm reset button Battery mode LED Load level LEDs The
  • IBM 21302RX | Installation Guide - Page 31
    level LEDs and the overload LED are lit, power requirements exceed uninterruptible power supply capacity. For more information, see "Troubleshooting guide" on page 39. Battery mode When the uninterruptible power supply is operating during a power outage, the alarm beeps once every 5 seconds, and
  • IBM 21302RX | Installation Guide - Page 32
    and the load level LEDs are off, indicating that power is not available to the connected devices. The battery recharges when necessary. Note: For 200 - 240 V models, the output receptacles might remain electrically live ( settings. 20 UPS 3000 LV and UPS3000 HV: Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 33
    the following LED legend for an explanation of the LEDs. LED legend Not lit Green Red Flashing For the factory default voltages for IBM uninterruptible power supply models, see Table 3 on page 22. Table 2. Configuration mode LEDs and options Configuration mode LEDs Option LED status 100/200
  • IBM 21302RX | Installation Guide - Page 34
    IBM 2130-1JX UPS Japan LV 100 V ac 40K9656 IBM 2130-1RX UPS 120 V ac 40K9793 IBM 2130-2JX UPS Japan HV 200 V ac 40K9657 IBM to the uninterruptible power supply. Starting the uninterruptible power supply on battery Note: Before you use this feature, the uninterruptible power supply must Guide
  • IBM 21302RX | Installation Guide - Page 35
    running while you turn off other devices. This feature enables you to save battery power. For more information, see your power-management software documentation. Note: If you are not using power-management software, you cannot control the individual load segments. Each uninterruptible power supply
  • IBM 21302RX | Installation Guide - Page 36
    24 UPS 3000 LV and UPS3000 HV: Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 37
    -ready cell phone or personal digital assistant (PDA) v Using SNMP-compatible network-management software (user-supplied) The Web/SNMP card also supports remote monitoring and shutdown from computer systems that are protected by uninterruptible power supplies. NetWatch client software that is used
  • IBM 21302RX | Installation Guide - Page 38
    history log files (data and events) for recording power problems. v Uninterruptible power supply status information is available to shows how you can use the Web/SNMP card in a network application. Management station or terminal UPS RS-232 ConnectUPS-X Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 39
    connector. Before you begin To use the configuration utility for the card, you need the following items: v The DB9-to-RJ-45 with the uninterruptible power supply v A terminal with a serial communication port, or a computer with a terminal emulation program. Set the serial line to 9600 baud, no parity
  • IBM 21302RX | Installation Guide - Page 40
    card. 2. Connect the other end of the serial cable into the TTY connector on the terminal or the COM connector on a computer sure that the Web/SNMP card has power (one or more LEDs on the card are lit) and that card To configure the Web/SNMP card, complete the following steps: 1. In the Web/SNMP Card
  • IBM 21302RX | Installation Guide - Page 41
    minutes to establish communication with the uninterruptible power supply. Wait before you attempt communication with the card from a Web browser or network management system (NMS). 2. For Telnet operation: After the card is accessible on the network, you can use a Telnet utility to modify any of the
  • IBM 21302RX | Installation Guide - Page 42
    ) Set Web/SNMP card control group To use BOOTP/DHCP, Telnet, or secure HTTP to configure, control, update, or manage the Web/SNMP card, you must enable the card is connected to the network. Set IP addresses of primary and secondary date server Computer systems with the Web/SNMP card-compatible
  • IBM 21302RX | Installation Guide - Page 43
    including the date of the installation and the date of the last battery replacement, select option 7. You can also set timing values that are in service-related situations. Set external contact monitoring With the Web/SNMP card (firmware v3.00), two separate contact closures are supported. Examples
  • IBM 21302RX | Installation Guide - Page 44
    card and xxx.xx.xxx.xx is the IP address of the computer card, from a computer, host computer, or server that is connected to a network, open a Web browser and connect to the Web/SNMP card Card Configuration to set the Web/SNMP card ConnectUPS Web/SNMP Card IP Address. the Web/SNMP card. Repeat steps
  • IBM 21302RX | Installation Guide - Page 45
    , for example, to NetWatch software clients or SNMP management tools, also stop. When you are finished using the Web/SNMP card in Serial Pass-through mode, disconnect the DB9-to-RJ-45 cable from the card and the workstation or notebook computer. Return the DIP switches to the original settings
  • IBM 21302RX | Installation Guide - Page 46
    34 UPS 3000 LV and UPS3000 HV: Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 47
    replaceable unit: You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge, under the type of warranty service that cable (UPS3000 HV model only) 39M5389 Uninterruptible power supply and battery care For the best preventive maintenance, keep the area around
  • IBM 21302RX | Installation Guide - Page 48
    has passed and the batteries were never recharged, do not use the uninterruptible power supply. Contact your technical-support representative. Replacing the electronics module (for trained service technician only) The this step. 36 UPS 3000 LV and UPS3000 HV: Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 49
    , call 1-800-426-4333. Have the IBM part number for the battery unit available when you call. (C004) If the battery service LED is flashing and the audible alarm is beeping once every 5 seconds, you might have to replace the battery module. Contact your technical-support representative to order new
  • IBM 21302RX | Installation Guide - Page 50
    flat, stable surface. For information about recycling the battery, see "Battery return program" on page 66. 5. Slide the new battery module into the uninterruptible power supply. 6. Reinstall the battery retaining bracket and nuts that you removed in step 3. 7. Replace the bezel. 38 UPS 3000 LV and
  • IBM 21302RX | Installation Guide - Page 51
    Table 7. Troubleshooting guide Alarm or batteries must be charged or serviced. Connect the uninterruptible power supply into an electrical outlet for 24 hours to charge the battery. If the Battery service LED is lit, see "Replacing Batteries" on page 44 to replace the battery. © Copyright IBM
  • IBM 21302RX | Installation Guide - Page 52
    Check the battery connections. Call your service correctly. representative if the problem persists. The battery must be replaced (trained service technician only). Contact your technical-support representative to order a new battery. Have the battery replaced by a trained service technician only
  • IBM 21302RX | Installation Guide - Page 53
    Table 7. Troubleshooting guide (continued) Alarm or condition Possible cause Action Power requirements exceed uninterruptible power off and disconnect the uninterruptible power supply. Contact your technical-support representative. The alarm cannot be silenced. Chapter 6. Troubleshooting 41
  • IBM 21302RX | Installation Guide - Page 54
    42 UPS 3000 LV and UPS3000 HV: Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 55
    v Use the troubleshooting information in your system documentation, and use the diagnostic tools that come with your system. Information about diagnostic tools is in the Problem Determination and Service Guide on the IBM Documentation CD that comes with your system. v Go to the IBM support Web site
  • IBM 21302RX | Installation Guide - Page 56
    In the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-7378). Hardware service and support You can receive hardware service through your IBM reseller or IBM Services. To locate a reseller authorized by IBM to provide warranty service, go to http://www.ibm.com/partnerworld/ and click Find a Business
  • IBM 21302RX | Installation Guide - Page 57
    , conversions, or upgrades involve the removal of parts and their return to IBM. A part that replaces a removed part will assume the warranty service status of the removed part. Unless IBM specifies otherwise, these warranties apply only in the country or region in which you purchased the Machine
  • IBM 21302RX | Installation Guide - Page 58
    money will be refunded. IBM or your reseller will also manage and install selected engineering changes that apply to the Machine. Exchange of a Machine or Part When the warranty service involves the exchange of a Machine or part, the item IBM or your reseller replaces becomes its property and the
  • IBM 21302RX | Installation Guide - Page 59
    your reseller considers necessary to fulfill its obligations under this Statement of Limited Warranty (which may include shipping the Machine for such processing to other IBM service locations around the world), and (c) ensure that such processing complies with any laws applicable to such Personal
  • IBM 21302RX | Installation Guide - Page 60
    IBM's rights, duties, and obligations arising from, or relating in any manner to, the subject matter of this Statement of Limited Warranty, without regard to conflict of law principles. THESE WARRANTIES GIVE YOU SPECIFIC Warranty Limited Warranty will of Limited Warranty will be Warranty will
  • IBM 21302RX | Installation Guide - Page 61
    Metropolitan Area Of the City of Caracas. NORTH AMERICA How to Obtain Warranty Service: The following is added to this Section: To obtain warranty service from IBM in Canada or the United States, call 1-800-IBM-SERV (426-7378). Appendix B. IBM Statement of Limited Warranty Z125-4753-08 04/2004 49
  • IBM 21302RX | Installation Guide - Page 62
    added to this section: Where IBM is in breach of a condition or warranty implied by the Trade Practices Act 1974 or other similar legislation, IBM's liability is limited to the repair or replacement of the goods or the Vacancies in the 50 UPS 3000 LV and UPS3000 HV: Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 63
    Warranty prevails over any other language version. HONG KONG S.A.R. OF CHINA AND MACAU S.A.R. OF CHINA Governing Law: The following replaces any situation involving nonperformance by IBM pursuant to, or in any way related to the subject of this Statement of Limited Warranty, the charge paid by you
  • IBM 21302RX | Installation Guide - Page 64
    : laws of the State of New York, United States of America (except when local law requires otherwise). PHILIPPINES Limitation of Liability: Item 3 in the fifth paragraph is replaced by the following: SPECIAL (INCLUDING NOMINAL AND EXEMPLARY DAMAGES), MORAL, INCIDENTAL, OR INDIRECT DAMAGES FOR ANY
  • IBM 21302RX | Installation Guide - Page 65
    any of those countries from either (1) an IBM reseller approved to perform warranty service or (2) from IBM, provided the Machine has been announced and made available by IBM in the country in which you wish to obtain service. If you purchased a Personal Computer Machine in Albania, Armenia, Belarus
  • IBM 21302RX | Installation Guide - Page 66
    Machine" is replaced by: 1) of Limited Warranty and relating Limited Warranty or of Limited Warranty or related Limited Warranty or related of Limited Warranty shall be Statement of Limited Warranty to the jurisdiction of Limited Warranty shall be Statement of Limited Warranty will be brought before
  • IBM 21302RX | Installation Guide - Page 67
    in such countries. How to Obtain Warranty Service: The following is added to this section: To obtain warranty service from IBM in EU countries, see the telephone listing in Part 3 - Warranty Information. You may contact IBM at the following address: IBM Warranty & Service Quality Dept. PO Box 30
  • IBM 21302RX | Installation Guide - Page 68
    replaces the terms of this section in its entirety: Except as otherwise provided by mandatory law: 1. IBM's liability for any damages and losses that may arise as a consequence of the fulfillment of its obligations under or in connection with this Statement of Limited Warranty and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 69
    replace any applicable statutory warranties. What this Warranty Covers: The following replaces the first sentence of the first paragraph of this section: The warranty for an IBM Machine covers the functionality of the Machine for its normal use and the Machine's conformity to its Specifications
  • IBM 21302RX | Installation Guide - Page 70
    for its normal use and the Machine's conformity to its Specifications. The following paragraphs are added to this section: The minimum warranty period for Machines is twelve months. In case IBM or your reseller is unable to repair an IBM Machine, you can alternatively ask for a partial refund as far
  • IBM 21302RX | Installation Guide - Page 71
    in respect of the subject matter of this Statement of Warranty will be limited to the charge paid by you for the individual Machine that is the subject of your claim from IBM. UNITED KINGDOM Limitation of Liability: The following replaces the terms of this section in its entirety: For the purposes
  • IBM 21302RX | Installation Guide - Page 72
    of the warranty period. IBM will charge you for any labor provided in performance of the repair or replacement(s) in the second and third year of the warranty period. Machine Types 2130-1RX, 2130-2RX Country or Region of Purchase Warranty Period Type of Warranty Service* Worldwide 3 years
  • IBM 21302RX | Installation Guide - Page 73
    or your reseller for country and location specific information. 1. Customer Replaceable Unit ("CRU") Service IBM provides replacement CRUs to you for you to install. CRU information and replacement instructions are shipped with your Machine and are available from IBM at any time on your request
  • IBM 21302RX | Installation Guide - Page 74
    warranty service is listed, IBM will determine which type of warranty service is appropriate for the repair. * This type of service is called ThinkPad EasyServ or EasyServ in some countries. The IBM Machine Warranty World Wide Web site at http://www.ibm.com/servers/ support and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 75
    and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent allow disclaimer of express or implied warranties in certain transactions, therefore, this IBM IBM (logo) Active Memory Active PCI i5/OS IBM Systems Director Active Energy Manager
  • IBM 21302RX | Installation Guide - Page 76
    Inc., in the United States and other countries. Other company, product, or service names may be trademarks or service marks of others. Important notes Processor speed indicates the internal clock speed of on operating environments. 64 UPS 3000 LV and UPS3000 HV: Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 77
    drive bays with the largest currently supported drives that are available from IBM. Maximum memory might require replacement of the standard memory with an optional memory module. IBM makes no representation or warranties regarding non-IBM products and services that are ServerProven®, including but
  • IBM 21302RX | Installation Guide - Page 78
    treatment, contact your local IBM representative. Battery return program This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride, lithium, or lithium ion battery. Consult your user manual or service manual for specific battery information. The battery must be recycled or
  • IBM 21302RX | Installation Guide - Page 79
    collection and treatment, contact your local IBM representative. This notice is provided in accordance with Royal Decree 106/2008 of Spain: The retail price of batteries, accumulators, and power cells includes the cost of the environmental management of their waste. For California: Perchlorate
  • IBM 21302RX | Installation Guide - Page 80
    Management Practices for Perchlorate Materials. This product/part may include a lithium manganese dioxide battery in accordance with the instruction manual, may cause harmful interference to meet FCC emission limits. IBM is not responsible for any radio IBM cannot accept responsibility for any
  • IBM 21302RX | Installation Guide - Page 81
    modification of the product, including the fitting of non-IBM option cards. This product has been tested and found to comply the user may be required to take adequate measures. European Community contact: IBM Technical Regulations Pascalstr. 100, Stuttgart, Germany 70569 Telephone: 0049 (0)711
  • IBM 21302RX | Installation Guide - Page 82
    Korean Class A warning statement 70 UPS 3000 LV and UPS3000 HV: Installation and Maintenance Guide
  • IBM 21302RX | Installation Guide - Page 83
    17 getting help 43 H hardware service and support 44 help, getting 43 I IBM Support Line 44 important notices 4 internal battery, connecting 10 inventory checklist 5 L LEDs Battery service 17 General alarm 17 Load level 18 On battery 17 Power-on 17 Site wiring 17 Web/SNMP card 27 Load level LEDs 18
  • IBM 21302RX | Installation Guide - Page 84
    controls and power 18 replaceable components 35 replacing battery module (trained service technician only) 37 replacing electronics module (trained service technician only) 36 specifications 3 starting on battery 22 storing battery 36 tower configuration 6 troubleshooting guide 39 turning off 22
  • IBM 21302RX | Installation Guide - Page 85
  • IBM 21302RX | Installation Guide - Page 86
    Part Number: 43W7864 Printed in USA (1P) P/N: 43W7864
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

UPS3000
LV
and
UPS3000
HV
Installation
and
Maintenance
Guide
±²³