IBM 4800-C41 Configuration Guide

IBM 4800-C41 Manual

IBM 4800-C41 manual content summary:

  • IBM 4800-C41 | Configuration Guide - Page 1
    Point Of Sale Linux Operating Systems Configuration Guide G362-0570-00
  • IBM 4800-C41 | Configuration Guide - Page 2
  • IBM 4800-C41 | Configuration Guide - Page 3
    Point Of Sale Linux Operating Systems Configuration Guide G362-0570-00
  • IBM 4800-C41 | Configuration Guide - Page 4
    applies to SUSE Linux Enterprise 11 and to all subsequent releases and modifications until otherwise indicated in new editions. IBM support for SUSE Linux Enterprise Point of Sale 11 is provided under product number 5799-HRL. Current versions of Retail Store Solutions documentation are available on
  • IBM 4800-C41 | Configuration Guide - Page 5
    support IBM SurePOS 100 4613-1x8 11 IBM SurePOS 300 4810-32x/33x/34x 12 IBM SurePOS 500 4840 13 IBM SurePOS 500 4846-5xx 13 IBM SurePOS 500 4851/4951-514 13 IBM SurePOS 700 4800-7x1 13 IBM SurePOS 700 4800-7x2 14 IBM SurePOS 700 4800-7x3 14 Chapter 3. SUSE Linux Enterprise Point of Service
  • IBM 4800-C41 | Configuration Guide - Page 6
    iv Linux OS Configuration
  • IBM 4800-C41 | Configuration Guide - Page 7
    IBM SurePOS™ 100 4613-1x8 v IBM SurePOS 300 4810-32x/33x/34x v IBM SurePOS 500 4846-5xx, 4851/4951 v IBM SurePOS 700 4800-72x/74x/78x Publications accessibility The softcopy version of this guide Point of Service 11 (SLEPOS 11) operating system, for supported IBM Point of Sale hardware devices.
  • IBM 4800-C41 | Configuration Guide - Page 8
    www.ibm.com/support/docview.wss?uid=pos1R4000246 Notice statements Notices in this guide are defined as follows: Notes These notices provide important tips, guidance, or advice. Important These notices provide information or advice that might help you avoid inconvenient or problem situations
  • IBM 4800-C41 | Configuration Guide - Page 9
    (Express) v IBM SurePOS 700 4800-721/722/723/741/742/743/781/782/783/C41/C42/C43 SLED 11 and SLES 11 installation procedures The posIBM_setserial utility comes in an RPM Package Manager (RPM) package and follows the normal RPM installation procedure: 1. Download the package from the IBM support site
  • IBM 4800-C41 | Configuration Guide - Page 10
    configuration and start building the image. Refer to the SLEPOS 11 guide at http://www.novell.com/documentation/slepos11/ for information about "on". # Valid values are "on" and "off" mouse=on 3. Reboot the system with the RS-485 touch screen attached. You should see these lines in the /etc/X11
  • IBM 4800-C41 | Configuration Guide - Page 11
    5xx SurePoint Solution v IBM SurePOS 500 4846-5xx v IBM SurePOS 700 4800-72x/74x/78x with serial-attached IBM 4820-2xx/4xx/5xx SurePoint Solution To calibrate a serial touch screen, you must provide the serial touch screen's minimum and maximum X and Y coordinates to X Window System. The following
  • IBM 4800-C41 | Configuration Guide - Page 12
    -2xx/4xx/5xx SurePoint Solution serial touch screen coordinates," if applicable to your installation. IBM SurePOS 700 4800-7x3/7x3/ 7x3 0, 1, 4, or 5 microtouch or See "IBM 4820-2xx/4xx/5xx SurePoint Solution serial touch elographics screen coordinates," if applicable to your installation. Table
  • IBM 4800-C41 | Configuration Guide - Page 13
    screen coordinates in xorg.conf To provide the X Window System with the specific minimum and maximum X and Y coordinates You can download the IBM_elotone4sle-1.0.0-0.i586.rpm package from IBM support web site at http://www.ibm.com/support/docview.wss?uid=pos1R4000246. To install the package on
  • IBM 4800-C41 | Configuration Guide - Page 14
    installed in these IBM Point of Sale hardware devices: v IBM 4694-207/247/307/347 v IBM AnyPlace Kiosk 4838-5xx/7xx/9xx v IBM SurePOS 100 4613-1x8 v IBM SurePOS 500 4840 v IBM SurePOS 700 4800-781/741/722/7x3 By default, these terminals use the FBdev when setup, which only supports a single display
  • IBM 4800-C41 | Configuration Guide - Page 15
    MSR, Intermac scanner, and Omni scanner configuration To configure a magnetic stripe reader (MSR) (0x4b3/4543), or an Intermac (0x4b3/454b) or Omni (0x4b3/454c) scanner: 1. On the command line, enter the following: mount -t usbfs usbfs /proc/bus/usb 2. If the scanner is driven correctly by the
  • IBM 4800-C41 | Configuration Guide - Page 16
    manually or configured together in SLEPOS 11 image creation according to the documentation for the latest release at the IBM Support applicable to your hardware): http://forgeftp.novell.com/driver-process/staging/pub/update/ibm/sle11/common/i586/ ibm-aipsvcp-kmp-pae-1.0_2.6.27.19_5-1.i586.rpm v
  • IBM 4800-C41 | Configuration Guide - Page 17
    JavaPOS provided in the package documentation to the /opt/ibm/javapos/etc/ directory: #cp /opt/ibm/javapos/docs/jposSample.xml /opt/ibm/javapos/etc/jpos.xml RMA packages installation Refer to the IBM Support documentation at http://www-01.ibm.com/support/docview.wss?rs=219 &uid=pos1R4000158 for the
  • IBM 4800-C41 | Configuration Guide - Page 18
    10 Linux OS Configuration
  • IBM 4800-C41 | Configuration Guide - Page 19
    systems, for these IBM Point of Sale hardware devices: v IBM 4694-207/247/307/347 v IBM 4820-1xx/2xx/4xx/5xx Display v IBM AnyPlace Kiosk 4836 and 4838-x3x/3xx/5xx/7xx/9xx v IBM SurePOS 100 4613-1x8 v IBM SurePOS 300 4810-32x/33x/34x v IBM SurePOS 500 4846-5xx, 4851/4951 v IBM SurePOS 700 4800
  • IBM 4800-C41 | Configuration Guide - Page 20
    300 4810-32x/33x/34x To fully configure SLED 11 to run on an IBM SurePOS 300 4810-32x/33x/34x: 1. Install SLED 11 according to the documentation at http://www.novell.com/documentation/sled11/ index.html. 2. (4810-34x only) Uninstall
  • IBM 4800-C41 | Configuration Guide - Page 21
    it to the PS/2 port on the system. IBM SurePOS 500 4846-5xx To fully configure SLED 11 to run on an IBM SurePOS 500 4846-5xx: 1. Install SLED 11 according screen calibration" on page 3. IBM SurePOS 700 4800-7x1 To fully configure SLED 11 to run on an IBM SurePOS 700 4800-7x1: 1. Install SLED 11
  • IBM 4800-C41 | Configuration Guide - Page 22
    "FBdev driver configuration" on page 6. 3. Perform the procedures in "Serial touch screen calibration" on page 3. IBM SurePOS 700 4800-7x3 To fully configure SLED 11 to run on an IBM SurePOS 700 4800-7x3: 1. Install SLED 11 according to the documentation at http://www.novell.com/documentation/sled11
  • IBM 4800-C41 | Configuration Guide - Page 23
    SurePOS 500 4846-545 v IBM SurePOS 500 4846-565 v IBM SurePOS 700 4800-741 v IBM SurePOS 700 4800-742 v IBM SurePOS 700 4800-743 v IBM SurePOS 700 4800-781 v IBM SurePOS 700 4800-782 v IBM SurePOS 700 4800-783 v IBM SurePOS 700 4800-C41 v IBM SurePOS 700 4800-C42 v IBM SurePOS 700 4800-C43 A system
  • IBM 4800-C41 | Configuration Guide - Page 24
    SLEPOS, these systems can only be used as SLEPOS client terminals: v IBM 4694-207/247/307/347 v IBM AnyPlace Kiosk 4836-x3x, 4838-x3x/3xx/5xx/7xx/9xx v IBM SurePOS 100 4613-1x8 v IBM SurePOS 300 4810-x2x/x3x/x4x v IBM SurePOS 500 4840-xx1/xx2/xx3, 4846-xx5, 4851-514 v IBM SurePOS 700 4800-7x1/7x2
  • IBM 4800-C41 | Configuration Guide - Page 25
    separately and must be either installed manually on a POS system (see "VIA display driver installation and configuration" on page 6) or built into a SLEPOS image (see "POS client image creation" on page 16). For dual video support, 4846-5x5 and 4840-xx3 are not supported because of X.Org and Intel
  • IBM 4800-C41 | Configuration Guide - Page 26
    18 Linux OS Configuration
  • IBM 4800-C41 | Configuration Guide - Page 27
    Appendix A. Safety information Danger: Before you begin to install this product, read the safety information in IBM Safety Information - Read This First, GA27-4004. This booklet describes safe procedures for cabling and plugging in electrical equipment. Gevaar: Voordat u begint met de installatie
  • IBM 4800-C41 | Configuration Guide - Page 28
    dient u eerst de veiligheidsrichtlijnen te lezen die zijn vermeld in de publikatie IBM Safety Information - Read This First, GA27-4004. In dit boekje wird, die Sicherheitshinweise in Sicherheitsinformationen-Bitte zuerst lesen, IBM Form GA27-4004. Diese Veröffentlichung beschreibt die
  • IBM 4800-C41 | Configuration Guide - Page 29
    Vigyázat Mielôtt megkezdi a berendezés üzembe helyezését, olvassa el a IBM Safety Information - Read This First, GA27-4004 könyvecskében leírt biztonsági információkat. Ez a könyv leírja, milyen biztonsági intézkedé
  • IBM 4800-C41 | Configuration Guide - Page 30
    Peligro Antes de empezar a instalar este producto, lea la información de seguridad en Información de Seguridad-Lea Esto Primero, GA27-4004. Este documento describe los procedimientos de sequridad para cablear y enchufar equipos eléctricos. Varning-livsfara Innan du börjar installera den här
  • IBM 4800-C41 | Configuration Guide - Page 31
    IBM IBM GA27-4004 GA27-4004 Appendix A. Safety information 23
  • IBM 4800-C41 | Configuration Guide - Page 32
    GA27-4004 IBM GA27-4004 GA27-4004 GA27-4004 GA27-4004 GA27-4004 24 Linux OS Configuration
  • IBM 4800-C41 | Configuration Guide - Page 33
    property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering the subject matter in this document. The furnishing of this document does not
  • IBM 4800-C41 | Configuration Guide - Page 34
    cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. This information is for planning purposes only. The information herein is subject to
  • IBM 4800-C41 | Configuration Guide - Page 35
    States or other countries, or both: v IBM v the IBM logo v AnyPlace v SurePOS v SurePoint Refer to http://www.ibm.com/legal/copytrade.shtml for more information. countries, or both. Other company, product, and service names may be trademarks or service marks of others. © Copyright IBM Corp. 2009 27
  • IBM 4800-C41 | Configuration Guide - Page 36
    28 Linux OS Configuration
  • IBM 4800-C41 | Configuration Guide - Page 37
    514 13 AnyPlace Kiosk 4836/4838 11 SurePOS 100 4613-1x8 11 SurePOS 300 4810-32x/33x/34x 12 SurePOS 500 4840 13 SurePOS 500 4846-5xx 13 SurePOS 500 4851/4951-514 13 SurePOS 700 4800-7x1 13 SurePOS 700 4800-7x2 14 SurePOS 700 4800-7x3 14 SUSE Linux Enterprise Point of Service 11 Admin Server 15 Branch
  • IBM 4800-C41 | Configuration Guide - Page 38
    System x server 15 T touch screen calibration, RS-232 3 touch screen calibration, RS-485 2 trademarks 27 V VIA display driver 6 video SUSE Linux Enterprise Point of Service 11 17 30 Linux OS Configuration
  • IBM 4800-C41 | Configuration Guide - Page 39
    We'd Like to Hear from You Point Of Sale Linux Operating Systems Configuration Guide Publication No. G362-0570-00 We appreciate your comments : Thank you for your support. Send your comments to the address on the reverse side of this form. If you would like a response from IBM, please fill in the
  • IBM 4800-C41 | Configuration Guide - Page 40
    IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST-CLASS MAIL PERMIT NO. 40 ARMONK, NEW YORK POSTAGE WILL BE PAID BY ADDRESSEE IBM Corporation Retail Store Solutions Information Development, Dept ZBDA P. O. Box 12195 RESEARCH TRIANGLE PARK NC 27709-9990 Fold and Tape Please do not staple
  • IBM 4800-C41 | Configuration Guide - Page 41
  • IBM 4800-C41 | Configuration Guide - Page 42
    G362-0570-00
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Point Of Sale
Linux Operating Systems Configuration
Guide
G362-0570-00
±²³