Insignia NS-AC14PWH8 User Guide

Insignia NS-AC14PWH8 Manual

Insignia NS-AC14PWH8 manual content summary:

  • Insignia NS-AC14PWH8 | User Guide - Page 1
    USER GUIDE 14,000 BTU Portable Air Conditioner NS-AC14PWH8 Before using your new product, please read these instructions to prevent any damage.
  • Insignia NS-AC14PWH8 | User Guide - Page 2
    your air conditioner after storage 28 Specifications 28 ONE-YEAR LIMITED WARRANTY 29 Introduction Congratulations on your purchase of a high-quality Insignia product. Your NS-AC14PWH8 represents state of the art design in portable air conditioning, designed for reliable and trouble-free
  • Insignia NS-AC14PWH8 | User Guide - Page 3
    symbol indicates that there are important operating and maintenance instructions in the literature accompanying your portable air conditioner. WARNING 1 Read these instructions. 2 Keep these instructions. 3 Heed all warnings. 4 Follow all instructions. 5 Do not use this machine near water. 6 Clean
  • Insignia NS-AC14PWH8 | User Guide - Page 4
    NS-AC14PWH8 17 Turn off the machine before unplugging it. 18 Refer all servicing to qualified service personnel. Servicing is required when the machine has been damaged in any way, or hard objects into the outlet air guide bars. • Turn the machine off and unplug it if there is water inside
  • Insignia NS-AC14PWH8 | User Guide - Page 5
    air conditioning unit unless three minutes have passed since being turned off, or the compressor may get damaged. WARNING Electric Shock Hazard Failure to follow these instructions air conditioner. If the power cord becomes worn or damaged, the cord should only be replaced by a qualified service
  • Insignia NS-AC14PWH8 | User Guide - Page 6
    NS-AC14PWH8 Electrical Safety Integrated circuit breaker For additional safety, the power cord on this air conditioner features an the RESET button does not stay engaged, unplug the air conditioner immediately and contact an Insignia technician. Preferred grounding method Make sure that a proper
  • Insignia NS-AC14PWH8 | User Guide - Page 7
    proper ground exists before use. To prevent damage to the adapter's ground terminal, hold the adapter in place while plugging or unplugging the air conditioner. Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and
  • Insignia NS-AC14PWH8 | User Guide - Page 8
    NS-AC14PWH8 Package contents • 14,000 BTU portable air conditioner • Remote Control (2 batteries included) • Drain hose • Exhaust hose • Hose adapter • Window seal plate assembly (window seal plates [2], security bracket, and four screws [two type A, one type B, and one type C]) • Quick Setup Guide
  • Insignia NS-AC14PWH8 | User Guide - Page 9
    14,000 BTU Portable Air Conditioner # Item Description 1 Air outlet Allows cool air to exit the air conditioner. Do not block. 2 Swiveling casters Allow you to move the air conditioner easily on most surfaces. Pre-installed. 3 Control panel and display Displays air conditioner settings. Press
  • Insignia NS-AC14PWH8 | User Guide - Page 10
    Back NS-AC14PWH8 # Item 1 Side handles (2) 2 Power cord 3 Upper filter 4 Air outlet 5 Lower filter 6 Drain outlet/cover Description Provides a convenient grip when moving your air conditioner. Plug this into a 115V 60 Hz AC outlet. Covers the upper air intake filter. Remove to clean the filter.
  • Insignia NS-AC14PWH8 | User Guide - Page 11
    Press to raise or lower settings. 3 Display Shows the temperature, timer, mode, and other important information. 4 MODE button Press to cycle the air conditioner through the available modes. Options include COOL, FAN, DRY, and ENERGY SAVER. 5 FAN speed button Press to select low, medium, or
  • Insignia NS-AC14PWH8 | User Guide - Page 12
    Accessories NS-AC14PWH8 # Item Description 1 Remote control Use to remotely control the air conditioner. 2 Hose adapter Connects the exhaust hose to the window installation kit to vent exhaust air outside. 3 Exhaust hose Used to vent exhaust air outside. 4 Window seal plate assembly Lets
  • Insignia NS-AC14PWH8 | User Guide - Page 13
    Function indicator Lights to show the current function. 6 (up) and (down) Press to adjust settings. buttons 7 MODE button Press to cycle the air conditioner through the available modes. Options include COOL, FAN, DRY, and ENERGY SAVER. 8 FAN button Press to select low, medium, or high speed
  • Insignia NS-AC14PWH8 | User Guide - Page 14
    NS-AC14PWH8 # Item 10 Battery indicator 11 Fan speed indicator 12 POWER button 13 Auto Swing button 14 Auto Clean button 15 °C -- °F button Description Shows the current battery charge in the remote control Indicates the current fan speed. Press to turn the air conditioner on or off. Press to turn
  • Insignia NS-AC14PWH8 | User Guide - Page 15
    unit on a flat, dry area near a window, so you can use the hose and adapter to connect the air conditioner to the window installation kit in order to vent the exhaust air outside. To maintain good air circulation and optimum machine performance, leave a 20 in. (50 cm) space around it. 20 in. (50 cm
  • Insignia NS-AC14PWH8 | User Guide - Page 16
    NS-AC14PWH8 Installing your air conditioner 1 Screw the exhaust hose to the air outlet on the back of your air conditioner, then screw the hose adapter to the other end of the hose. 2 Measure the window size. OR 3 Install the window sealing plate in the window
  • Insignia NS-AC14PWH8 | User Guide - Page 17
    14,000 BTU Portable Air Conditioner 4 Insert the hose adapter into the vent panel, then slide it down or left until it clicks into place. Small gap First insert Second slide www.insigniaproducts.com 17
  • Insignia NS-AC14PWH8 | User Guide - Page 18
    NS-AC14PWH8 5 If desired, secure the hose adapter to the vent panel with a type B screw. Type B screw • For optimum performance, do not twist the venting hose. For better efficiency, shorten the hose, if possible. Caution The exhaust duct is designed especially for this air conditioner. Replacing or
  • Insignia NS-AC14PWH8 | User Guide - Page 19
    drain hose for DRY mode operation (optional) If you want to continuously drain the water from your air conditioner and never have to manually drain the collection tank, do the following: 1 Unplug your air conditioner and move it to a location where you can work on it. 2 Remove the water plug from
  • Insignia NS-AC14PWH8 | User Guide - Page 20
    NS-AC14PWH8 4 Place the open end of the hose in a suitable location to drain continuously this function if there is no water in the collection tank. 5 Plug in your air conditioner and restart it. 6 Set your air conditioner to DRY mode using either the remote control or the control panel. 20 www.
  • Insignia NS-AC14PWH8 | User Guide - Page 21
    not use rechargeable batteries. • When you replace the batteries, always replace them with new batteries. No not mix old and new batteries. • If your air conditioner will not be used for an extended period of time, remove the batteries from the remote control. Cautions • If the fluid from inside the
  • Insignia NS-AC14PWH8 | User Guide - Page 22
    NS-AC14PWH8 Using the air conditioner You can control your air conditioner by using the control panel on the front of the unit, or by using the remote control. If using the remote control, always point it at the air conditioner. Button POWER MODE FAN   \ TIMER Description Press to turn your air
  • Insignia NS-AC14PWH8 | User Guide - Page 23
    Troubleshooting Caution Do not try to repair your portable air conditioner yourself. Doing so invalidates the warranty. Problem Possible cause Possible solution Air conditioner does not The air conditioner use of the air conditioner and contact a qualified service technician. Water Full
  • Insignia NS-AC14PWH8 | User Guide - Page 24
    NS-AC14PWH8 Problem Possible cause Possible solution The air conditioner runs The area to be cooled is too Consult your Insignia technician for the air conditioner capacity too often or too long large for the air conditioner. required to cool the desired area. Doors or windows are open. Make
  • Insignia NS-AC14PWH8 | User Guide - Page 25
    Center can provide this inspection and cleaning for a nominal fee. Warning • Unplug the air conditioner before cleaning or performing any maintenance or service. • Be careful when cleaning coils or removing or reinstalling the filter. The cooling fins are very sharp. • Failure to follow the above
  • Insignia NS-AC14PWH8 | User Guide - Page 26
    filter grill out by the handle. Open here NS-AC14PWH8 Upper filter Upper filter grill 3 Clean the upper Let the filter dry completely, then reinstall it in the air conditioner. Note • When the filter is not replaced in the air conditioner correctly, there is a gap between the filter case and
  • Insignia NS-AC14PWH8 | User Guide - Page 27
    collection tank is full, "FL" or "Water Full" appears on the LED display and your air conditioner turns off until the tank is emptied. Notes • When operating or draining water from your air conditioner, always protect carpeting and floors from possible water spillage. • When you drain the water from
  • Insignia NS-AC14PWH8 | User Guide - Page 28
    NS-AC14PWH8 Storing your air conditioner If your air conditioner will not be used for an extended period of time, we suggest that you prepare it for storage by doing the following: 1 Unplug your air conditioner. 2 Remove the rubber plug and drain the water collection tank completely. 3 Reinstall
  • Insignia NS-AC14PWH8 | User Guide - Page 29
    Air Conditioner ONE-YEAR LIMITED WARRANTY Definitions: The Distributor* of Insignia branded products warrants to you, the original purchaser of this new Insignia packaging. To obtain warranty service, in the United States refrigerator or freezer • Customer instruction/education • Installation • Set
  • Insignia NS-AC14PWH8 | User Guide - Page 30
    NS-AC14PWH8 • Negligence • Commercial purposes/use, including but not limited to use in a • Connection to an incorrect voltage or power supply • Attempted repair by any person not authorized by Insignia to service the Product • Products sold "as is" or "with all faults" • Consumables, including but
  • Insignia NS-AC14PWH8 | User Guide - Page 31
    www.insigniaproducts.com 1-877-467-4289 (U.S. and Canada) or 01-800-926-3000 (Mexico) INSIGNIA is a trademark of Best Buy and its affiliated companies. Distributed by Best Buy Purchasing, LLC 7601 Penn Ave South, Richfield, MN 55423 U.S.A. ©2017 Best Buy.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

Before using your new product, please read these instructions to prevent any damage.
USER GUIDE
14,000 BTU Portable
Air Conditioner
NS-AC14PWH8