Intel S3200SHV Product Specification

Intel S3200SHV - Entry Server Board Motherboard Manual

Intel S3200SHV manual content summary:

  • Intel S3200SHV | Product Specification - Page 1
    Intel® Server Boards S3200SH/S3210SH Technical Product Specification Intel Order Number: E14960-009 Revision 1.8 May, 2010 Enterprise Platforms and Services Division
  • Intel S3200SHV | Product Specification - Page 2
    ® Server Boards S3200SH/S3210SH TPS Revision History Date Sept. 2007 Oct. 2007 Jan. 2008 Apr. 2008 July 2008 Sept. 2008 Jan. 2009 Feb. 2009 May 2010 Revision Number 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 Initial release. Modifications Added new updates. Corrected some document errors. Added Intel
  • Intel S3200SHV | Product Specification - Page 3
    2.2 Server Board Layout 10 2.2.1 Server Board Mechanical Drawings 11 3. Functional Architecture ...13 3.1 Processor Sub-System 15 3.1.1 Processor Voltage Regulator Down (VRD 15 3.1.2 3.2 3.2.1 Reset Configuration Logic 15 Intel® 3200/3210 Chipset 16 Intel® 3200/3210 Chipset MCH: Memory
  • Intel S3200SHV | Product Specification - Page 4
    Intel® Server Boards S3200SH/S3210SH TPS 4.3 BIOS Setup Utility 44 4.3.1 Operation ...44 4.3.2 Server Platform Setup Screens 47 4.4 Loading BIOS Defaults 75 4.5 Multiple Boot Blocks 75 4.6 Recovery Mode...75 4.7 Intel® Matrix Storage Manager 76 4.8 Intel® Embedded Server RAID
  • Intel S3200SHV | Product Specification - Page 5
    Intel® Server Boards S3200SH/S3210SH TPS Table of Contents 6.7 Miscellaneous Headers and Connectors 92 6.7.1 Back Panel I/O Connectors 92 6.7.2 Chassis Intrusion Header 93 6.7.3 HDD Active LED Header Compliance Markings 105 8.4 Electromagnetic Compatibility Notices 106 8.4.1 FCC (USA
  • Intel S3200SHV | Product Specification - Page 6
    Table of Contents Intel® Server Boards S3200SH/S3210SH TPS Glossary ...113 Reference Documents...116 vi Revision 1.8 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 7
    Positions 11 Figure 6. Intel® Server Boards S3210SHLC/S3200SHL/S3200SHV - Hole and Component Positions...12 Figure 7. Intel® Server Boards S3200SH/S3210SH LC/L/V SKU-Block Diagram 13 Figure 8. Intel® Server Systems S3200SH/S3210SH LX SKU-Block Diagram 14 Figure 9. Memory Bank Label Definition 27
  • Intel S3200SHV | Product Specification - Page 8
    Intel® Server Boards S3200SH/S3210SH TPS Figure 33. Setup Utility - Exit Screen Display 73 Figure 34. Example of Diagnostic LEDs on Server Board 81 Figure 35. Intel® Server Board S3210SHLX / S3210SHLC / S3200SHL Back Panel I/O Connectors ...92 Figure 36. Intel® Server Board S3200SHV Back Panel
  • Intel S3200SHV | Product Specification - Page 9
    Intel® Server Boards S3200SH/S3210SH TPS List of Tables List of Tables Table 1. Intel® Server Board S3210SHLX Board SKU Layout Reference 7 Table 2. Intel® Server Board S3210SHLC Layout Reference 8 Table 3. Processor Support Matrix 16 Table 4. Segment F Connections 17 Table 5. Supported DDR2
  • Intel S3200SHV | Product Specification - Page 10
    . POST Error Beep Codes 85 Table 48. Power Connector Pin-out (J4G1 86 Table 49. Auxiliary CPU Power Connector Pin-out (J9B2 86 Table 50. SMBus Connector Pin-out (J1E1 87 Table 51. Front Panel 24-Pin Header Pin-out (J1K2 87 Table 52. VGA Connector Pin-out (J8B1 88 Table 53. NIC2-Intel® 82541PI
  • Intel S3200SHV | Product Specification - Page 11
    ® Server Boards S3200SH/S3210SH TPS List of Tables Table 69. Turn On/Off Timing 100 Table 70. Transient Load Requirements 101 Table 71. AC Line Sag Transient Performance 101 Table 72. AC Line Surge Transient Performance 102 Table 73. Product Certification Markings 105 Revision 1.8 xi Intel
  • Intel S3200SHV | Product Specification - Page 12
    List of Tables Intel® Server Boards S3200SH/S3210SH TPS < This page intentionally left blank. > xii Revision 1.8 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 13
    4 - System BIOS ƒ Chapter 5 - Error Reporting and Handling ƒ Chapter 6 - Connectors and Jumper Blocks ƒ Chapter 7 - Absolute Maximum Ratings ƒ Chapter 8 - Design and Environmental Specifications ƒ Chapter 9 - Hardware Monitoring ƒ Glossary ƒ Reference Documents 1.2 Server Board Use Disclaimer Intel
  • Intel S3200SHV | Product Specification - Page 14
    to support the entry server market. 2.1 ƒ ƒ ƒ Server Board Feature Set All board SKUs are based on the Intel® 3200/3210 Chipset Supports processors in LGA775 package 800/1066/1333 MHz Front Side Bus (FSB) speed Four DDR2 667/800MHz unbuffered DIMM memory sockets with or without ECC Supports the
  • Intel S3200SHV | Product Specification - Page 15
    , and fans) ƒ VRD11 for processor The server board supports the following feature set: ƒ Processor and FSB support o Supports Intel® Xeon® processor 3000 series, Intel® Xeon® processor 3100 series, Intel® Xeon® processor 3200 series, and Intel® Xeon® processor 3300 series. o Supports Intel® dual
  • Intel S3200SHV | Product Specification - Page 16
    Server Board Overview Intel® Server Boards S3200SH/S3210SH TPS ƒ Video ƒ ServerEngines* Integrated BMC (Baseboard management controller) ƒ External 32 MB (or greater) DDR2 533 MHz memory ƒ VGA Video to the server rear panel o Two USB 2.0 ports connected to headers on the server board o One
  • Intel S3200SHV | Product Specification - Page 17
    Intel® Server Boards S3200SH/S3210SH TPS Server Board Overview ƒ System Management o Processor on die temperature monitoring through PECI (Platform Environment Control Interface) o Board temperature measurement o Fan speed monitoring and control o Voltage monitoring o IPMI-based (Intelligent
  • Intel S3200SHV | Product Specification - Page 18
    Server Board Overview Intel® Server Boards S3200SH/S3210SH TPS o One 4-pin SATA RAID Key o One 2-pin intrusion detection ƒ BIOS o EFI BIOS ƒ Power Management o Support for Power Management of all capable components o ACPI-compliant motherboard and BIOS o Sleep Switch and dual mode LED indicator ƒ
  • Intel S3200SHV | Product Specification - Page 19
    Clear Jumper BB Front Panel Connector CC Chassis Intrusion Jumper DD Floppy Connector EE Internal USB FF External USB GG CMOS Clear Jumper HH BMC Force Update Jumper II BIOS Recovery Jumper JJ BMC Boot Block WP Jumper KK Serial Port Connector Revision 1.8 7 Intel Order Number: E14960
  • Intel S3200SHV | Product Specification - Page 20
    Table 2. Intel® Server Board S3210SHLC Layout Reference Ref Description A PCI (32-bit/33 MHz) Slot 1 B PCI (32-bit/33 MHz) Slot 2 C PCI Express* x8 (x8 lane) D PCI Express* x8 (x4 lane) E PCI Express* x16 F System Fan 1 Connector G Back Panel Connectors H Diagnostic LEDs I Processor Fan
  • Intel S3200SHV | Product Specification - Page 21
    Table3. Intel® Server Boards S3200SH-L/S3200SH-V Component Layout Reference Ref Description A PCI (32-bit/33 MHz) Slot 1 B PCI (32-bit/33 MHz) Slot 2 C PCI Express* x8 (x4 lane) D PCI Express* x16 (x8 lane) E System Fan 1 Connector F Back Panel Connectors G Diagnostic LEDs H Processor Fan
  • Intel S3200SHV | Product Specification - Page 22
    Server Board Overview 2.2 Server Board Layout Intel® Server Boards S3200SH/S3210SH TPS Figure 4. Intel® Server Board S3210SHLC 10 Revision 1.8 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 23
    Intel® Server Boards S3200SH/S3210SH TPS 2.2.1 Server Board Mechanical Drawings Server Board Overview Figure 5. Intel® Server Board S3210SHLX - Hole and Component Positions Revision 1.8 11 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 24
    Server Board Overview Intel® Server Boards S3200SH/S3210SH TPS Figure 6. Intel® Server Boards S3210SHLC/S3200SHL/S3200SHV - Hole and Component Positions 12 Revision 1.8 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 25
    blocks that make up the Intel® Server Boards S3200SH/S3210SH. PCIe* x16 (Slot 6) PCIe* x8 (Slot 5) DMI Controller Link PCI-E x8 (Slot 4) SMBus PWM/TACH PCI 32 (Slot 1) PCI 32 (Slot 2) SATA SATA SATA Figure 7. Intel® Server Boards S3200SH/S3210SH LC/L/V SKU-Block Diagram Revision 1.8 13
  • Intel S3200SHV | Product Specification - Page 26
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS PWM/TACH Figure 8. Intel® Server Systems S3200SH/S3210SH LX SKU-Block Diagram 14 Revision 1.8 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 27
    micro-architecture. They maintain compatibility with 32-bit software written for the IA-32 instruction set, while supporting 64-bit native mode operation when coupled with supported 64-bit operating systems and applications. 3.1.1 Processor Voltage Regulator Down (VRD) The server board has a VRD
  • Intel S3200SHV | Product Specification - Page 28
    Intel® Server Boards S3200SH/S3210SH TPS Process Name Intel® Xeon® processor 3000 series Intel® Xeon® processor 3100 series Intel® Xeon® processor 3200 series Intel® Xeon® processor 3300 series Table 3. Processor Support Matrix Socket Intel® LGA775 Intel® LGA775 Intel® LGA775 Intel® LGA775
  • Intel S3200SHV | Product Specification - Page 29
    Intel® Server Boards S3200SH/S3210SH TPS Intel® ICH9R Other features provided by the MCH include the following: ƒ Full support of ECC on the processor bus ƒ Twelve deep in-order queue, two deep defer queue ƒ Full support of unbuffered DDR2 ECC DIMMs ƒ Support for 512 MB, 1 GB, and 2 GB DDR2 memory
  • Intel S3200SHV | Product Specification - Page 30
    Functional Architecture Lane Lane 0~7 Intel® Server Boards S3200SH/S3210SH TPS Device Slot 6 (PCI Express* x16 with 8 Lanes layout) 3.2.1.2 MCH Memory Sub-System Overview The MCH supports a 72-bit wide memory sub-system that can support a maximum of 8 GB of DDR2 memory using 2 GB DIMMs. This
  • Intel S3200SHV | Product Specification - Page 31
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture ƒ Supports ECC or non-ECC DIMMs. ƒ Different memory technologies (size 64-bit PCI-X slots On Segment E, PCI-X is capable of speeds up to 133 MHz operation and supports full-length PCI and PCI-X adapters. 3.2.2.1.1 Device IDs (IDSEL)
  • Intel S3200SHV | Product Specification - Page 32
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS Baseboard Signals PCIX REQ_N1/GNT_N1 PCIX REQ_N0/GNT_N0 Device PCI-X Slot 1 (64-bit/66-133 MHz) (LX board SKU only) PCI-X Slot 2 (64-bit/66-133 MHz) ( LX board SKU only) 3.2.3 3.2.3.1 Intel® ICH9R: I/O Controller Hub 9R Direct
  • Intel S3200SHV | Product Specification - Page 33
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture 3.2.3.7 Compatibility Modules The Intel® ICH9 incorporates various compatibility providing support for twelve USB 2.0 ports. All twelve ports are high-speed, full-speed, and low-speed capable. The port routing logic of the Intel®
  • Intel S3200SHV | Product Specification - Page 34
    the Platform Environmental Control Interface (PECI) that provides access to the CPU thermal data. The server board does not support ME or Intel® QST. The integrated BMC firmware controls the fan speed. 3.2.3.14 Serial Peripheral Interface (SPI) The Serial Peripheral Interface (SPI) is a 4-pin
  • Intel S3200SHV | Product Specification - Page 35
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture When SPI is selected by the Boot BIOS Destination Strap and a SPI Device is detected by the Intel® ICH9, LPC-based BIOS Flash is disabled. The boot destination strap is sampled by the ICH9 at pins GNT# and SPI_CS1# on the rising edge
  • Intel S3200SHV | Product Specification - Page 36
    instruction after reset ƒ ECC Error reporting from the host controller ƒ A Function Disable option to prevent disabled functions from generating interrupts and power management events ƒ An Intruder Detect input for system cases 3.2.3.16 Unused Intel® ICH9 Interfaces on the Server Board The server
  • Intel S3200SHV | Product Specification - Page 37
    SATA interface CD-ROM/DVD-ROMs are recommended for use with the server board. 3.2.3.19 SATA Controller The Intel® ICH9R contains six SATA ports that support data transfer rates up to 300 Mbyte/s per port. 3.2.3.20 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller) The
  • Intel S3200SHV | Product Specification - Page 38
    Intel® Server Boards S3200SH/S3210SH TPS 3.3 Memory Sub-System The server board supports up to four DIMM slots for a maximum memory capacity of 8 GB. The DIMM organization is x72, which includes eight ECC check bits. The memory interface runs at 533/667 MTs. The memory controller supports
  • Intel S3200SHV | Product Specification - Page 39
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture Table 10. Memory Bank Labels and DIMM Population Order Location J8J1 J8J2 J9J1 J9J2 DIMM Label (DIMM_1A) (DIMM_2A) (DIMM_1B) (DIMM_2B) Channel A A B B Population Order 1 3 2 4 Figure 9. Memory Bank Label Definition Revision 1.8
  • Intel S3200SHV | Product Specification - Page 40
    corrected. Multiple-bit errors (MBE) can only be detected. ƒ The maximum memory capacity is 8 GB via four 2 GB DIMM modules. ƒ The minimum memory capacity is 512 MB via a single 512 MB DIMM module. 3.4 I/O Sub-System 3.4.1 PCI Subsystem The primary I/O buses for the server board are five independent
  • Intel S3200SHV | Product Specification - Page 41
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture Table 12. PCI Bus Segment Characteristics PCI Bus Segment A B C D E F Voltage 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V Width 32 bits 1 lane 1 lane 4 lane 64 bits 8 lanes Speed 33 MHz 2.5 GHz 2.5 GHz 2.5 GHz 66/100/133 MHz 2.5 GHz Type PCI
  • Intel S3200SHV | Product Specification - Page 42
    (32-bit/33 MHz) 3.4.1.2 PCI Interface for Video subsystem The server board graphics subsystem is connected to the Intel® ICH9R with a PCI Express* x1 bus. 3.4.2 Interrupt Routing The board interrupt architecture accommodates both PC-compatible PIC mode and APIC mode interrupts through the use
  • Intel S3200SHV | Product Specification - Page 43
    interrupt. Floaty processor. Compatibility IDE interrupt from primary channel IDE devices 0 and 1 Secondary IDE Cable System Management Interrupt: General purpose indicator sourced by the Intel® ICH9R to the processor 3.4.2.4 Serialized IRQ Support The server board supports a serialized interrupt
  • Intel S3200SHV | Product Specification - Page 44
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS 3.4.3 PCI Error Handling The PCI bus defines two error pins, PERR# and SERR#, for reporting PCI parity errors and system errors, respectively. In the case of PERR#, the PCI bus master has the option to retry the offending transaction
  • Intel S3200SHV | Product Specification - Page 45
    Intel® Server Boards S3200SH/S3210SH TPS IRQ0 IRQ1 IRQ2 IRQ3 IRQ4 IRQ5 IRQ6 IRQ7 IRQ8 IRQ9 IRQ10 IRQ11 IRQ12 IRQ13 IRQ14 IRQ15 IRQ16 IRQ17 IRQ18 IRQ19 IRQ20 IRQ21 IRQ22 IRQ23 Intel® ICH9R Intel® ICH9R IOAPIC 0 Functional Architecture DMI INTERFACE Intel® ICH9R 8259PIC x8 Connector x8 PCI
  • Intel S3200SHV | Product Specification - Page 46
    Intel® Server Boards S3200SH/S3210SH TPS Intel® ICH9R Interrupt Routing PCI Interface Serialized IRQ Interface Timer Super I/O Keyboard Cascade Serial Port2/ISA Serial Port1/ISA ISA Floppy/ISA ISA RTC SCI/ISA ISA ISA Mouse/ISA Coprocessor Error P IDE/ISA Not Used N/A Intel
  • Intel S3200SHV | Product Specification - Page 47
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture PCI-X slot 6 INTD# PCI-X slot 6 INTA# PCI-X slot 6 INTC# PCI-X slot 6 INTB# PCI-X slot 5 INTD# PB IRQ14 PB IRQ15 PCI-X Interface PXH-V Figure 12. PXH-V Interrupt Routing Diagram Revision 1.8 35 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 48
    Intel® Server Boards S3200SH/S3210SH TPS 3.5 BMC Controller The Integrated Baseboard Management Controller (Integrated BMC) is a highly integrated single-chip solution, integrating several devices typically found on servers. The Integrated BMC is mainly targeted at next generation servers
  • Intel S3200SHV | Product Specification - Page 49
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture ƒ Eight Fan Tach Inputs ƒ Four Pulse Width Modulators (PWM) ƒ Chassis Intrusion Logic with battery backed general purpose register ƒ LED support with programmable blink rate control ƒ Programmable IO Port snooping, which can be used
  • Intel S3200SHV | Product Specification - Page 50
    to manually select FSB/host clock frequency ƒ SMBus interface for spread spectrum support ƒ Option to retain register contents in PWRDWN# state 3.8 Super I/O There is a Winbond* PC8374L super I/O located on the Intel® ICH9 LPC bus. This device uses the following features on the server board: ƒ LPC
  • Intel S3200SHV | Product Specification - Page 51
    is not supported. 3.11 On-Board Components 3.11.1 Video Support The server board includes an integrated VGA graphics engine in Integrated BMC that supports standard VGA drivers with analog display capabilities. The graphics subsystem has 8 MB memory to support the onboard video controller. The
  • Intel S3200SHV | Product Specification - Page 52
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS controller is disabled by default in BIOS Setup when an off-board video adapter is detected in either the PCI Express* or PCI slots. 40 Revision 1.8 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 53
    Intel® Server Boards S3200SH/S3210SH TPS Functional Architecture 3.11.1.1 2D Mode 640x480 800x600 1024x768 1280x1024 1280x1024 1600x1200 1600x1200 3D Mode 640x480 800x600 1024x768 1280x1024 1600x1200 3D Mode 640x480 800x600 1024x768 1280x1024 1600x1200 Video Modes Refresh Rate (Hz) 60, 72, 75,
  • Intel S3200SHV | Product Specification - Page 54
    Functional Architecture Intel® Server Boards S3200SH/S3210SH TPS 3.12 Replacing the Back-Up Battery The lithium battery on the server board powers the RTC for up to ten years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in
  • Intel S3200SHV | Product Specification - Page 55
    clock MM = Two-digit minute For example, Intel® Server Board S3200SH BIOS Build 3, generated on Jan 21, 2006 at 11:59 AM displays the following BIOS ID string in the POST diagnostic screen: S3200.86B.01.00.0003.012120061159 The BIOS version in the Setup Utility displays as: S3200.86B.01.00.0003 The
  • Intel S3200SHV | Product Specification - Page 56
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS 4.2 Logo / Diagnostic Window The logo / diagnostic window may information ƒ BIOS ID ƒ Total memory detected (total size of all installed DIMMs) ƒ Processor information (Intel branded string, speed, and number of physical processors identified) ƒ
  • Intel S3200SHV | Product Specification - Page 57
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Functional Area Title Bar Setup Item List Item Specific Help Area Keyboard Command Bar Status Bar Table 18. BIOS Setup Page Layout Description The title bar is located at the top of the screen and displays the title of the form (page) the user
  • Intel S3200SHV | Product Specification - Page 58
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Key Option Execute Command Exit - Select Item Select Item Select Menu Select Field Change Value + Change Value Setup Defaults Table 19. BIOS the plus key has a different scan code than the plus key on the other
  • Intel S3200SHV | Product Specification - Page 59
    BIOS Intel® Server Boards S3200SH/S3210SH TPS 4.3.2 Server Platform Setup Screens The following sections describe the screens available for the configuration of a server platform. The tables in these sections describe the contents of each screen. These tables follow these guidelines: ƒ The BIOS
  • Intel S3200SHV | Product Specification - Page 60
    Boards S3200SH/S3210SH TPS System BIOS Main Advance d Security Server Management Boot Options Boot Manager Logged in as Platform ID BIOS Version Build Date Processor Intel® Xeon® CPU Core Frequency Memory Size Quiet Boot POST Error
  • Intel S3200SHV | Product Specification - Page 61
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Setup Item Logged in as Platform ID System BIOS Version Build Date Processor Core Frequency Count Memory Size Quiet Boot POST Error Pause Table 20. Setup Utility - Main Screen Fields Options Help Text Comments
  • Intel S3200SHV | Product Specification - Page 62
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Setup Item System Date System Time Options [Day of week MM Advanced Screen The Advanced screen provides an access point to configure several options such as processor, memory, SATA controller, and so forth. On this screen, the user selects the
  • Intel S3200SHV | Product Specification - Page 63
    BIOS Intel® Server Boards S3200SH/S3210SH TPS Table 21. Setup Utility - Advanced Screen Display Fields Setup Item Processor Configuration Memory Configuration SATA Controller Configuration Serial Port Configuration USB Configuration PCI Configuration Options Help Text View/Configure processor
  • Intel S3200SHV | Product Specification - Page 64
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Table 22. Setup Utility - Processor Configuration Screen Fields Setup Item Processor Family Core Frequency Maximum Frequency System Bus Frequency L2 Cache RAM Processor Stepping CPUID Register Options Enhanced Intel Enabled SpeedStep®
  • Intel S3200SHV | Product Specification - Page 65
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS To access this screen from the Main screen, select Advanced | Memory. Advanced Memory Configuration Total Memory Effective Memory Current Configuration Current Memory Speed DIMM Information DIMM_A1 DIMM_A2 DIMM_B1 DIMM_B2 Memory Correction <
  • Intel S3200SHV | Product Specification - Page 66
    Intel® Server Boards S3200SH/S3210SH TPS Setup Item Current Configuration Options System BIOS Comments Information only. Displays one of the following: Dual Channel: System memory is configured for optimal performance and efficiency. Single Channel: System memory is functioning in a special,
  • Intel S3200SHV | Product Specification - Page 67
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Advanced SATA Controller Configuration Onboard SATA Controller Configure SATA as Enabled / Disabled IDE / AHCI/ RAID ► SATA Port 0 ► SATA Port 1 ► SATA Port 2 ► SATA Port 3 ► SATA Port 4 ► SATA Port 5 Not Installed/ Not
  • Intel S3200SHV | Product Specification - Page 68
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Setup Item Onboard SATA Controller Configure SATA as SATA Port 0 SATA Port 1 SATA Port 2 SATA Port 3 SATA Port 4 SATA Port 5 Table 24. Setup Utility - ATA Controller Configuration Screen Fields Options Enabled Disabled SATA RAID IDE < Not
  • Intel S3200SHV | Product Specification - Page 69
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Advanced Serial Port Configuration Serial A Enable Address IRQ Serial B Enable Address IRQ Enabled/Disabled 3F8h / 2F8h this screen from the Main screen, select Advanced | USB Configuration. Revision 1.8 57 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 70
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Advanced USB Configuration Detected USB Devices USB Controller Legacy USB Support Enabled / Disabled Enabled / Disabled / Auto USB Mass Storage Device Configuration Device Reset timeout 10 sec / 20 sec / 30 sec
  • Intel S3200SHV | Product Specification - Page 71
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Table 26. Setup Utility - USB Controller OS vendor regarding OS support of this feature. 4.3.2.2.6 PCI Screen The PCI Screen provides fields to configure PCI add-in cards, the onboard NIC controllers, and video options. To access
  • Intel S3200SHV | Product Specification - Page 72
    Intel® Server Boards S3200SH/S3210SH TPS Advanced PCI Configuration Dual Monitor Video Onboard NIC ROM NIC 1 MAC Address NIC 2 MAC Address Enabled / Disabled Enabled / Disabled System BIOS Figure 20. Setup Utility - PCI Configuration Screen Display Setup Item Dual Monitor Video
  • Intel S3200SHV | Product Specification - Page 73
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Main Advanced Security Server Management Boot Options Boot Manager Administrator Password Status User Password Status Set Administrator Password Set User Password Front Panel Lockout [
  • Intel S3200SHV | Product Specification - Page 74
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS 4.3.2.4 Server Management Screen The Server Management screen provides fields to configure several server management features such as enabling FRB-2, clearing the system event log, and so forth. It also provides an access point to the screens
  • Intel S3200SHV | Product Specification - Page 75
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Setup Item Clear System Event BIOS programs the watchdog timer with the timeout value selected. If the OS does not complete booting before the timer expires, the BMC will reset the system and an error will be logged. Requires OS support or Intel
  • Intel S3200SHV | Product Specification - Page 76
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Console Redirection Console Redirection Flow Control Baud Rate Terminal Type Legacy OS Redirection Server Management Disabled / Serial for hardware flow control. Serial port transmission speed. Setting must match the remote terminal application
  • Intel S3200SHV | Product Specification - Page 77
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS 4.3.2.5 Server Management System Information Screen The Server Management System Information screen provides a place to see part numbers, serial numbers, and firmware revisions. To access this screen from the Main screen, select Server
  • Intel S3200SHV | Product Specification - Page 78
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS 4.3.2.6 Boot Options Screen The Boot Options screen displays any bootable media encountered during POST and allows the user to configure the boot device. To access
  • Intel S3200SHV | Product Specification - Page 79
    BIOS Intel® Server Boards S3200SH/S3210SH TPS Table 32. Setup Utility - Boot Options Screen Fields Setup Item Boot Timeout Boot Option #x Boot Option Retry Hard Disk Order CDROM Order Floppy Order Network Device Order BEV Device Order Help Text The number of seconds BIOS Bootstrap Entry Vector
  • Intel S3200SHV | Product Specification - Page 80
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Table 33. Setup Utility - Hard Disk Order Fields Setup Item Hard Disk #1 Hard Disk #2 Options Available hard position. Set hard disk boot order by selecting the boot option for this position. 68 Revision 1.8 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 81
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS 4.3.2.6.2 CDROM Order Screen The CDROM Order screen provides a way to control CD- Figure 28. Setup Utility - Floppy Order Screen Display Revision 1.8 69 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 82
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS Setup Item Floppy Disk #1 Floppy Disk #2 Table 35. Setup Utility - Floppy Order Fields Options Available onboard network devices with a PXE option ROM are two examples of network boot devices. 70 Revision 1.8 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 83
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS 4.3.2.6.5 BEV Device Order Screen The BEV Device Order screen provides a way to control the BEV (Bootstrap Entry Vector) bootable devices. To access this screen from the Main screen, select Boot Options | BEV Device Order. BEV Device #1 BEV
  • Intel S3200SHV | Product Specification - Page 84
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS 4.3.2.7 Boot Manager Error Manager Screen The Error Manager screen displays any errors encountered during POST. Error Manager ERROR CODE Exit SEVERITY INSTANCE Figure 32. Setup Utility - Error Manager Screen Display 72 Revision 1.8 Intel
  • Intel S3200SHV | Product Specification - Page 85
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS Setup Item Displays System Errors Table 39. Setup Utility - Error Manager Screen Fields Options Help Text Comments Information only. Displays errors that occurred during this POST. 4.3.2.9 Exit Screen The Exit screen allows the user to
  • Intel S3200SHV | Product Specification - Page 86
    FW and FRUSDR provide HW monitoring, fan speed control, and system management features. Intel released FRUSDRs will contain the fan speed control support for Intel® server chassis by default. The supported chassis are: ƒ Intel® Server Chassis SR1530 ƒ Intel® Entry Server Chassis SC5299-UP For any
  • Intel S3200SHV | Product Specification - Page 87
    System BIOS Intel® Server Boards S3200SH/S3210SH TPS 4.4 Loading BIOS Defaults Different mechanisms exist for resetting the system configuration to the default values. When a request to reset the system configuration is detected, the BIOS loads the default system configuration values during the
  • Intel S3200SHV | Product Specification - Page 88
    Intel® Server Boards S3200SH/S3210SH TPS System BIOS The following steps illustrate the recovery process: 1. Power off the system and insert recovery media. 2. Switch the recovery jumper. 3. Power on the system. 4. The BIOS POST screen appears and displays the progress, and the system
  • Intel S3200SHV | Product Specification - Page 89
    Intel® Server Boards S3200SH/S3210SH TPS Error Reporting and Handling 5. Error Reporting and Handling This chapter defines the following error handling features: ƒ Error Handling and Logging ƒ Error Messages and Beep Codes 5.1 Error Handling and Logging This section defines how errors are handled
  • Intel S3200SHV | Product Specification - Page 90
    Reporting and Handling Intel® Server Boards S3200SH/S3210SH TPS 5.1.2 Error Logging via SMI Handler The SMI (System Management Interrupt) handler manages and logs system level events. The SMI handler pre-processes all system errors, even those that are normally considered to generate an NMI
  • Intel S3200SHV | Product Specification - Page 91
    Intel® Server Boards S3200SH/S3210SH TPS Error in an event-log entry as defined in the memory error Y Multi-bit ECC memory error Y Parity memory error N Bus time-out N I/O Channel Check N Software NMI N POST Memory Resize N POST Error Y PCI Parity Error Y PCI System Error Y CPU
  • Intel S3200SHV | Product Specification - Page 92
    Error Reporting and Handling Intel® Server Boards S3200SH/S3210SH TPS Value 16h 17h 18h-7Fh 80h-FEh FFh Description Log Area Reset/Cleared Y System boot. If implemented, this log entry is N guaranteed to be the first one written on any system boot. Unused, available for assignment by N
  • Intel S3200SHV | Product Specification - Page 93
    Intel® Server Boards S3200SH/S3210SH TPS Error Reporting and Handling ƒ Green bits = 1100b = Ch Since the red bits correspond to the upper nibble and the green bits correspond to the lower nibble, the two are concatenated to be ACh. LEDs ACh Result Table 44. POST Progress Code LED Example Red 1
  • Intel S3200SHV | Product Specification - Page 94
    Error Reporting and Handling Intel® Server Boards S3200SH/S3210SH TPS Checkpoint Diagnostic LED Decoder G=Green, R=Red, A=Amber MSB LSB 0x26h OFF G A OFF 0x27h OFF G A G 0x28h G OFF R OFF PCI Bus 0x50h OFF R OFF R 0x51h
  • Intel S3200SHV | Product Specification - Page 95
    Intel® Server Boards S3200SH/S3210SH TPS Error Reporting driver execution phase (DXE) Reserved for DXE core use Started connecting drivers Started dispatching a driver Completed dispatching a driver Waiting for user input Checking password Entering BIOS setup Flash Update Calling Int 19; one beep
  • Intel S3200SHV | Product Specification - Page 96
    Error Reporting and Handling Intel® Server Boards S3200SH/S3210SH TPS Checkpoint 0xF5h 0xF8h Diagnostic LED Decoder G=Green, R=Red, A=Amber MSB LSB R A R A A R R R 0xF9h A R R A 0xFAh A R A R Pre-EFI Initialization Module (PEIM) / Recovery 0x30h OFF OFF R R 0x31h OFF
  • Intel S3200SHV | Product Specification - Page 97
    Intel® Server Boards S3200SH/S3210SH TPS Error Reporting and Handling 5.2.4 POST Error Beep Codes The following table lists POST error beep codes. Prior to system video initialization, the BIOS uses these beep codes to inform users of error conditions. The beep code is followed by a uservisible
  • Intel S3200SHV | Product Specification - Page 98
    Intel® Server Boards S3200SH/S3210SH TPS Connectors and Jumper Blocks 6. Connectors and Jumper COM 18 AWG Color Orange Blue Black Green Black Black Black N.C. Red Red Red Black Table 49. Auxiliary CPU Power Connector Pin-out (J9B2) Pin Signal 1 COM 2 COM 3 COM 4 COM 18 AWG color Pin
  • Intel S3200SHV | Product Specification - Page 99
    the Intel® Server Board S3200SH-L into the Intel® Server Chassis SR1530. 6.3 SMBus Connector Table 50. SMBus Connector Pin-out (J1E1) Pin Signal Name 1 SMB_DAT_5V_BP 2 GND 3 SMB_CLK_5V_BP 4 TP_BP_I2C_HRD_4 Description Data Line GROUND Clock Line Test Point 6.4 Front Panel Connector
  • Intel S3200SHV | Product Specification - Page 100
    Intel® Server Boards S3200SH/S3210SH TPS Connectors and Jumper Blocks 6.5 I/O Connectors 6.5.1 VGA B15 B8 6.5.2 NIC Connectors The server board supports two NIC RJ-45 connectors. The following tables detail the pin-out of the connectors. Table 53. NIC2-Intel® 82541PI (10/100/1000) Connector
  • Intel S3200SHV | Product Specification - Page 101
    Connectors and Jumper Blocks Intel® Server Boards S3200SH/S3210SH TPS Table 54. NIC1- Intel® 82566E (10/100/1000) Connector Pin-out (J6B1) Signal Name P2V5_NIC1 NIC1_MDI0_DP NIC1_MDI0_DN NIC1_MDI1_DP NIC1_MDI1_DN NIC1_MDI2_DP NIC1_MDI2_DN NIC1_MDI3_DP NIC1_MDI3_DN GND NIC1_LINK_1_N Pin Signal
  • Intel S3200SHV | Product Specification - Page 102
    Intel® Server Boards S3200SH/S3210SH TPS Connectors and Jumper Blocks Signal Name GND GND Unused GND GND GND GND Unused GND GND GND Pin 13 15 17 19 21
  • Intel S3200SHV | Product Specification - Page 103
    Connectors and Jumper Blocks Intel® Server Boards S3200SH/S3210SH TPS 6.5.6 Keyboard and Mouse Connector Two PS/2 ports are provided for a P5V_USB_BP_MJ USB_BACK5_R_DN USB_BACK5_R_DP GND P5V_USB_BP_MJ USB_BACK4_R_DN USB_BACK4_R_DP GND Signal Name Revision 1.8 91 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 104
    Heceta* to monitor the FAN speed. Pulse Width Modulation - Fan Speed Control signal 6.7 Miscellaneous Headers and Connectors 6.7.1 Back Panel I/O Connectors Figure 35. Intel® Server Board S3210SHLX / S3210SHLC / S3200SHL Back Panel I/O Connectors 92 Revision 1.8 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 105
    and Jumper Blocks Keyboard Intel® Server Boards S3200SH/S3210SH TPS Serial A LAN Mouse VGA POST Code LED USB Figure 36. Intel® Server Board S3200SHV Back Panel I/O Connectors 6.7.2 Chassis Intrusion Header A 1x2 pin header (J1B2) is used in chassis that support a chassis intrusion switch
  • Intel S3200SHV | Product Specification - Page 106
    to the Intel® Entry Server Chassis SC5299-E SATA hot-swap backplane. 6.8 Jumper Blocks This section describes the configuration jumper options on the server board. Name CMOS Clear Password Clear Recovery Mode BMC Force Update Mode BMC Boot Block Write Protection Location on LC/L/V J1E3 Location
  • Intel S3200SHV | Product Specification - Page 107
    Intel® Server Boards S3200SH/S3210SH TPS 6.8.2 BMC Force Update Procedure When performing a standard BMC firmware update procedure, the update utility places the BMC into an update mode, allowing the firmware to load safely onto the flash device. In the unlikely event the BMC firmware update
  • Intel S3200SHV | Product Specification - Page 108
    must provide proper airflow to avoid exceeding the processor maximum case temperature. 2. VDD is the supply voltage for server boards as configured from the factory. Product Code Intel® Server Board S3200SH-L Intel® Server Board S3200SH-V Intel® Server Board S3210SH-LX Intel® Server Board S3210SH-LC
  • Intel S3200SHV | Product Specification - Page 109
    and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS 8. Design and Environmental Specifications 8.1 Power Budget The following table shows the power consumed on each supply line for the server board that is configured with one processor (128W max). This configuration includes
  • Intel S3200SHV | Product Specification - Page 110
    Intel® Server Boards S3200SH/S3210SH TPS Design and Environmental Specifications 8.2 Power Supply Specifications This section provides power supply design guidelines for the server board, including voltage and current specifications, and power supply on/off sequencing characteristics. Parameter +
  • Intel S3200SHV | Product Specification - Page 111
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS The 5VSB output voltage rise time will be from 1.0ms to 25.0ms. Vout 10% Vout V1 V2 V3 V4 Tvout_rise Tvout_on Tvout_off Figure 37. Output Voltage Timing Revision 1.8 99 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 112
    Intel® Server Boards S3200SH/S3210SH TPS Design and Environmental Specifications Table 69. Turn On/Off Timing Item output voltage stays within regulation after loss of AC. Min 21 20 5 100 1 100 50 70 Max 1500 2500 400 50 1000 200 1000 Units msec msec msec msec msec msec msec msec msec msec msec
  • Intel S3200SHV | Product Specification - Page 113
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS 8.2.2 Dynamic Loading is only a test specification. The step load may occur anywhere within the MIN load to the MAX load conditions. Table 70. Transient Load Requirements Output +3.3V +5V 12V +5VSB Step Load Size
  • Intel S3200SHV | Product Specification - Page 114
    Intel® Server Boards S3200SH/S3210SH TPS Design and Environmental Specifications Duration Continuous 0 Class B chassis does not result in a Class B device. 8.3.1 Product Safety Compliance The server board complies with the following safety requirements: ƒ UL60950 - CSA 60950(USA / Canada) ƒ
  • Intel S3200SHV | Product Specification - Page 115
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS 8.3.2 Product EMC Compliance - Class A Compliance Note: Legally, the product of Conformity (New Zealand) BSMI Declaration (Taiwan) RRL Certification (Korea) Revision 1.8 103 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 116
    Intel® Server Boards S3200SH/S3210SH TPS Design and Environmental Specifications ƒ RoHS (Restriction of Hazardous Substances Directive) Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002/95/EC. Compliance is based on declaration
  • Intel S3200SHV | Product Specification - Page 117
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS 8.3.4 Product Regulatory Compliance Markings This Australia / New Zealand Korea Exporting Requirements Environmental Requirements CPU-S3200SH (A) MADE IN xxxxx Revision 1.8 105 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 118
    Intel® Server Boards S3200SH/S3210SH TPS Design and Environmental Specifications 8.4 Electromagnetic Compatibility Notices 8.4.1 FCC (USA) This device and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is
  • Intel S3200SHV | Product Specification - Page 119
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS 8.4.2 ICES-003 (Canada) Cet it may cause radio interference. Install and use the equipment according to the instruction manual. 8.4.5 Taiwan Declaration of Conformity (BSMI) The BSMI Certification Marking and EMC
  • Intel S3200SHV | Product Specification - Page 120
    Intel® Server Boards S3200SH/S3210SH TPS 8.4.6 Korean Compliance (RRL) Design and Environmental Specifications English translation of the notice above: Type of Equipment (Model Name): On License and Product Certification No.: On RRL certificate. Obtain certificate from local Intel representative
  • Intel S3200SHV | Product Specification - Page 121
    Specifications Intel® Server Boards S3200SH/S3210SH TPS 8.5 Mechanical Specifications The following figure shows the Intel® Server Board S3200SH mechanical drawing. An updated version of this drawing will appear in a future revision of this document. Figure 39. Intel® Server Board S3200SH
  • Intel S3200SHV | Product Specification - Page 122
    use in pedestal mount applications, such as the Intel® Entry Server Chassis SC5299-E, for the three board SKUs. The Intel® Server Board S3200SH-L and the Intel® Server Board S3200SH-LX/LC share the same I/O shield, and Intel® Server Board S3200SH-V employs a separate I/O shield. Figure 40. Pedestal
  • Intel S3200SHV | Product Specification - Page 123
    Design and Environmental Specifications Intel® Server Boards S3200SH/S3210SH TPS Figure 41. Pedestal Mount I/O Shield Mechanical Drawing for Intel® Server Boards S3200SHL/S3210SH-LX Revision 1.8 111 Intel Order Number: E14960-009
  • Intel S3200SHV | Product Specification - Page 124
    Intel® Server Boards S3200SH/S3210SH TPS Hardware Monitoring 9. Hardware Monitoring 9.1 Chassis Intrusion The server board supports a chassis security feature that detects removal of the chassis cover. For the chassis intrusion circuit to function, the chassis' power supply must be connected to
  • Intel S3200SHV | Product Specification - Page 125
    of battery-backed 128 bytes of memory, which normally resides on the server board. Data Carrier Detect Dual In-Line Memory Module Direct Memory Access Distributed Management Task Force Error Correcting Code Electromagnetic Compatibility External Product Specification Extended System Configuration
  • Intel S3200SHV | Product Specification - Page 126
    Intel® Server Boards S3200SH/ RAID I/O Steering Random Access Memory Ring Indicate Reduced instruction set computing Remote Management Control Protocol Read Only Memory Real Time Clock Single-Bit Error System Configuration Interrupt Sensor Data Record Synchronous Dynamic RAM Definition 114 Intel
  • Intel S3200SHV | Product Specification - Page 127
    Intel® Server Boards S3200SH/S3210SH TPS Term SEL SERIRQ SERR SM SMI SMM SMS SNMP SPD SSI SSI EEB TPS UART USB VGA VID VRM Word ZCR System event log Definition Serialized Interrupt Requests System Error Server Management Server management interrupt. SMI is the highest priority non-maskable
  • Intel S3200SHV | Product Specification - Page 128
    Intel® Server Boards S3200SH/S3210SH TPS Reference Documents Reference Documents Refer to the following documents for additional information: ƒ Intel® S3200 Server Board Family Datasheet ƒ Intel® 3200 Series Chipset Memory Controller Hub Datasheet. ƒ Intel® ICH9 I/O Controller Hub Datasheet. 116
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

Intel
®
Server Boards S3200SH/S3210SH
Technical Product Specification
Intel Order Number: E14960-009
Revision 1.8
May, 2010