Intel SC5299DPNA User Manual

Intel SC5299DPNA Manual

Intel SC5299DPNA manual content summary:

  • Intel SC5299DPNA | User Manual - Page 1
    Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Intel Order Number D37596-002
  • Intel SC5299DPNA | User Manual - Page 2
    or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be claimed as the property of others. Copyright © 2006, Intel Corporation. All Rights Reserved ii Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 3
    in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel® Server Deployment Toolkit CD and/or at http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie
  • Intel SC5299DPNA | User Manual - Page 4
    inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. iv Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 5
    of accessories or other components you may need, troubleshooting information, and instructions on how to add and replace components on the Intel® Entry Server Chassis SC5299-E. For the latest version of this manual, see http:/ /support.intel.com/support/motherboards/server/chassis/sc5299-e/. Manual
  • Intel SC5299DPNA | User Manual - Page 6
    drive, RAID controller, operating system. For information about which accessories, memory, processors, and third-party hardware have been tested and can be used with your server board, and for ordering information for Intel® products, see http://support.intel.com/support/motherboards/server/chassis
  • Intel SC5299DPNA | User Manual - Page 7
    To make sure your system falls within the allowed power budget For software to manage your Intel® server Power Budget Tool at http://support.intel.com/support/motherboards/server/chassis/ sc5299-e Intel® System Management Software Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide vii
  • Intel SC5299DPNA | User Manual - Page 8
    Preface viii Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 9
    Processor Air Duct 15 Installing or Removing a Server Board 16 Installing and Removing a Fixed Hard Drive 22 Installing a Fixed Hard Drive 22 Removing a Fixed Hard Drive 28 Installing or Removing a DVD-ROM or CD-ROM Drive 31 Installing a DVD-ROM or CD-ROM Drive 31 Intel® Entry Server Chassis
  • Intel SC5299DPNA | User Manual - Page 10
    Swap Power Supply Cage (BRP configuration only 49 Installing Feet for a Pedestal-configured Chassis 54 Hot Swap Drive Cage Upgrade Install Instructions (optional 55 Before You Begin ...55 Kits Required ...55 Tools and Supplies Needed 55 System References ...55 Installing a Hot Swap Hard Drive
  • Intel SC5299DPNA | User Manual - Page 11
    ...132 D. Intel® Server Issue Report Form 135 E. Warranty ...139 Limited Warranty for Intel® Chassis Subassembly Products 139 Extent of Limited Warranty 139 Warranty Limitations and Exclusions 140 Limitations of Liability 140 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide xi
  • Intel SC5299DPNA | User Manual - Page 12
    How to Obtain Warranty Service 140 Telephone Support ...141 Returning a Defective Product 141 F. Regulatory and Compliance Information 143 Product Regulatory Substances (RoHS) Compliance 149 End of Life / Product Recycling 149 xii Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 13
    Installing Processor Air Duct 16 Figure 15. Removing Drive Cage EMI Shield from Fixed Drive Cage 17 Figure 16. Removing Fixed Hard Drive Cage 18 Figure 17. Removing PCI Card Guide 18 Figure 18. Re-installing PCI Card Guide into Chassis 19 Figure 19. Inserting Fixed Hard Drive Cage into Chassis
  • Intel SC5299DPNA | User Manual - Page 14
    68. Securing Hot Swap Power Supply Cage to Inside of Chassis 52 Figure 69. Re-installing Hot Swap Power Supply Module(s 53 Figure 70. Installing Feet on Chassis 54 Figure 71. Removing Fixed Drive Cage EMI Shield from Chassis 56 Figure 72. Removing Fixed Hard Drive Cage from Chassis 57 Figure 73
  • Intel SC5299DPNA | User Manual - Page 15
    on Chassis 81 Figure 107. Detaching Inner Rack Rail from Rack Rail Assembly 82 Figure 108. Attaching Inner Rack Rails to Chassis 83 Figure 109. Attaching Outer Rack Rails to Rack Uprights 84 Figure 110. Installing Chassis into Rack 85 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 16
    xvi Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 17
    1. Breakdown of Intel® Entry Server Chassis SC5299-E Configurations 1 Table 2. Server Chassis Features 2 Table 3. Accessories and Order Codes 10 Table 4. 550-W Power Supply Output Capability 87 Table 5. 670-W Power Supply Output Capability 88 Table 6. 650-W Power Supply Output Capability 88
  • Intel SC5299DPNA | User Manual - Page 18
    xviii Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 19
    ://support.intel.com/support/motherboards/server/ chassis/sc5299-e/. 1. The Intel® Entry Server Chassis SC5299-E can be configured as a rack-mountable server chassis when outfitted with the optional Rack Mount Kit (order code APP3RACKIT). Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 20
    • Processor fans for active thermal solution • Fan with optional hot swap drive kit upgrade • Fixed hard drive fan with WS chassis configuration • Two front panel USB ports NOTES: 1. Power supply fan integrated into power supply module. 2 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 21
    Front View Components A Server Chassis Features B C D E TP02345 A. 5.25-in Device Drive Bays B. Front Panel C. Drive Bay Access Door D. Door Lock E. Front Panel USB Ports Figure 2. Front View Components (with Front Bezel Assembly) Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 3
  • Intel SC5299DPNA | User Manual - Page 22
    Chassis Features A B C D E TP00882 A. 5.25-in Device Drive Bays B. 3.5-in Device Drive Bay C. Hard Drive Cage D. Drive Bay EMI Shield (shown open) E. Front Panel USB Ports Figure 3. Front View Components (without Front Bezel Assembly) 4 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 23
    Retention Mechanism F. PCI Add-in Card Guide G. Front Panel USB Ports H. Fixed Hard Drive Cage I. Large Processor Air Duct J. Rear Tool-less PCI Retention Mechanisms K. Fan Duct / System Fan Assembly L. Power Supply Figure 4. Internal Components Intel® Entry Server Chassis SC5299-E DP/WS/BRP User
  • Intel SC5299DPNA | User Manual - Page 24
    chassis configuration purchased B. A/C Power In NOTE: Fixed Power Supply shown. Your Power Supply may vary depending on chassis configuration purchased. C. Alternate external SCSI knockout D. System Fan E. I/O Shield NOTE: I/O connectors vary, depending on the server board installed. See your server
  • Intel SC5299DPNA | User Manual - Page 25
    indicates a power fault, fan fault, or a non-critical temperature or voltage fault. No light indicates a fatal error during POST. NOTES: 1. LED status may vary depending on server board integrated. Figure 6. Front Panel Components Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 7
  • Intel SC5299DPNA | User Manual - Page 26
    six hot-swappable SCSI, SATA or SAS hard drives) may be purchased to replace the fixed hard drive cage. See Table 3 for order code information. For instructions on installing hard drives, see "Installing and Removing a Fixed Hard Drive". 8 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 27
    Systems Your Intel® Entry Server Chassis SC5299-E can be optionally mounted into a rack. Instructions for installing your chassis into a rack are included with the rail kit. The order number for the rack mounting kit is APP3RACKIT. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 9
  • Intel SC5299DPNA | User Manual - Page 28
    http://support.intel.com/go/serverbuilder Table 3. Accessories and Order Codes Accessory SAS/SATA Hot Swap Drive Bay Upgrade Kit SCSI Hot Swap Drive Bay Upgrade Kit Hot Swap Conversion Kit Rack Mount Kit Order Code AXX6SASDB AXX6SCSIDB APP3HSDBKIT APP3RACKIT 10 Intel® Entry Server Chassis SC5299
  • Intel SC5299DPNA | User Manual - Page 29
    as it would be positioned for pedestal operation. Removing and Installing the Left Side Cover Warning: This chassis must be operated with the left side cover installed to ensure proper cooling. Removing the Left Side Cover The Intel® Entry Server Chassis SC5299-E must be operated with the left
  • Intel SC5299DPNA | User Manual - Page 30
    securely (see letter "A" in the following figure). 2. (Optional) Replace screws (see letter "B"). B A B TP00831 Figure 10. Installing Left Side Cover 3. Reconnect all peripheral devices and the AC power cord. Power up the server. 12 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 31
    and Upgrades Removing and Installing the Front Bezel Assembly All configurations of the Intel® Entry Server Chassis SC5299-E ship with a two-piece front bezel assembly. Removing the Front Bezel Assembly 1. Observe the safety and ESD precautions listed in Appendix A, "Safety Information". 2. Turn
  • Intel SC5299DPNA | User Manual - Page 32
    A D C TP02035 Figure 12. Installing the Front Bezel Assembly 2. Reinstall the left side cover. For instructions, see "Installing the Left Side Cover". 3. Reconnect all peripheral devices and the AC power cable. Power up the server. 14 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 33
    proper airflow within the chassis. Warning: The processor air duct must only be used with active thermal solutions. When adding or replacing a processor, first remove the processor air duct, and then refer to your server board User Guide for instructions on processor installation and removal. Return
  • Intel SC5299DPNA | User Manual - Page 34
    and unplug all peripheral devices and the AC power cable. 3. Remove the left side cover. For instructions, see "Removing the Left Side Cover". 4. Remove the front bezel assembly. For instructions, see "Removing the Front Bezel Assembly". 16 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 35
    EMI Shield from Fixed Drive Cage 6. Disconnect cables from any installed fixed hard drives. If necessary, remove hard drives from fixed hard drive cage. For instructions on removing fixed hard drives, see "Removing a Fixed Hard Drive". Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 17
  • Intel SC5299DPNA | User Manual - Page 36
    Drive Cage 8. Remove any PCI add-in boards that are present. 9. Remove the PCI card guide by pressing in on the blue tabs (see letter "A" in the following figure) and pulling the PCI card guide outward (see letter "B"). A B TP01732 Figure 17. Removing PCI Card Guide 18 Intel® Entry Server Chassis
  • Intel SC5299DPNA | User Manual - Page 37
    Intel® Server Board User's Guide and/or Quick Start User's Guide for additional removal instructions. 12. Reinstall the processor air duct. For instructions, see "Installing the Processor Air Duct". 13. Re-install the PCI card guide. Insert tabs on left side of PCI card guide into slots in chassis
  • Intel SC5299DPNA | User Manual - Page 38
    mechanism locks into place. TP02039 Figure 19. Inserting Fixed Hard Drive Cage into Chassis 15. If previously removed, install fixed hard drives and connect power and data cables. For instructions, see "Installing a Fixed Hard Drive". 20 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 39
    and Installing the Front Bezel Assembly" 18. Re-install the left side cover. For instructions, see "Installing the Left Side Cover" 19. Plug all peripheral devices and the AC power cable(s) back into the server. Power up the server. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 21
  • Intel SC5299DPNA | User Manual - Page 40
    be installed in the fixed hard drive cage that ships with the Intel® Entry Server Chassis SC5299-E. Power requirements for each individual hard drive may limit the maximum number of drives that can be integrated into the server chassis. Note: The Intel® Entry Server Chassis SC5299-E does not support
  • Intel SC5299DPNA | User Manual - Page 41
    and remove the drive cage EMI shield (see letter "A" in the following figure). A B TP01869 Figure 22. Removing Drive Cage EMI Shield from Chassis 6. Remove any PCI add-in boards that use the PCI card guide. For instructions, see "Removing PCI Add-in Boards". Intel® Entry Server Chassis SC5299-E DP
  • Intel SC5299DPNA | User Manual - Page 42
    Figure 23. Removing PCI Card Guide 8. Route the required power cables (connectors P8-P13) from behind the PCI card guide through the cable routing area at the bottom of the fixed drive cage. AF000317 Figure 24. Routing Hard Drive Power Cables 24 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User
  • Intel SC5299DPNA | User Manual - Page 43
    25. Unlatching Drive Latch 10. Insert fixed hard drive into drive bay and push until it stops. Ensure that the power and data connector end of the hard drive is facing forward AF000319 Figure 26. Inserting Hard Drive into Drive Cage Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 25
  • Intel SC5299DPNA | User Manual - Page 44
    Latch 12. Install additional drives as necessary. Warning: Drive bay slots 1, 3, and 5 MUST be populated first. Failure to do so could result in thermal issues within the chassis. 1 2 3 4 5 6 AF000316 Figure 28. Drive Bay Slot Order 26 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 45
    opening at the bottom of the fixed drive cage. AB AF000429 Figure 29. Cabling a Fixed Hard Drive 14. Re-attach the drive cage EMI shield to the chassis and tighten the thumb screw. AF000315 Figure 30. Re-installing Drive Cage EMI Shield Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 27
  • Intel SC5299DPNA | User Manual - Page 46
    peripheral devices and the AC power cable. 3. Remove the left side cover. For instructions, see "Removing the Left Side Cover". 4. Remove the front bezel assembly. For instructions, see "Removing and Installing the Front Bezel Assembly". 28 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 47
    removed (see letter "A" in the following figure). Pull the drive latch forward (see letter "B") to unlatch the drive locking mechanism for the hard drive you want to remove. B A AF000430 Figure 32. Preparing Fixed Hard Drive for Removal Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 29
  • Intel SC5299DPNA | User Manual - Page 48
    Figure 34. Re-installing Drive Cage EMI Shield 9. Re-install the front bezel assembly. For instructions, see "Installing the Front Bezel Assembly" 10. Re-install the left side cover. For instructions, see "Installing the Left Side Cover" 30 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 49
    For instructions, see "Removing the Front Bezel Assembly". 5. Remove the EMI shield from the 5.25-in device drive bay (see letter "A" in the following figure). Move latch to the "unlock" position (see letter "B"). B A TP01063 Figure 35. Removing 5.25-in Drive EMI Shield Intel® Entry Server Chassis
  • Intel SC5299DPNA | User Manual - Page 50
    the power supply) and data cables to the rear of the CD-ROM or DVD-ROM drive (see letter "F"). D F E C TP01064 Figure 36. Installing CD-ROM or DVD-ROM Drive 7. If necessary, remove the filler panel from the front bezel assembly. TP01723 32 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 51
    -ROM drive (see letter "A" in the following figure). Move latch to the "unlock" position (see letter "B"). Slide CD-ROM or DVD-ROM drive out of the Device Drive Bay (see letter "C"). A B C TP02047 Figure 37. Removing CD-ROM or DVD-ROM Drive Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 52
    all peripheral devices and the AC power cable(s). Power up the server. Installing the Removing PCI Add-in Boards The following instructions describe how to install and remove a PCI add-in board in the Intel® Entry Server Chassis SC5299-E. These instructions are server board dependent. See your
  • Intel SC5299DPNA | User Manual - Page 53
    Installations and Upgrades 3. Remove the left side cover. For instructions, see "Removing the Left Side Cover". 4. Open the back panel PCI Add-in Card Retention Device by pressing open from the inside of the chassis 's instructions. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 35
  • Intel SC5299DPNA | User Manual - Page 54
    and ESD precautions listed in Appendix A, "Safety Information". 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the left side cover. For instructions, see "Removing the Left Side Cover". 36 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 55
    Hardware Installations and Upgrades 4. Open the back panel PCI Add-in Card Retention Device by pressing open from the inside of the chassis. TP02049 Figure 42. Opening PCI Add-in Card BB A TP01724 Figure 43. Removing PCI Add-in Board Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 37
  • Intel SC5299DPNA | User Manual - Page 56
    devices and the AC power cable. 3. Remove the left side cover. For instructions, see "Removing the Left Side Cover" 4. Remove the front bezel assembly if it is installed. For instructions, see "Removing the Front Bezel Assembly". 38 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 57
    the right side cover off the chassis. A A TP01736 Figure 45. Removing Right Side Cover from Chassis 6. Remove the three screws securing the front panel board to the chassis. TP01737 Figure 46. Unattaching Front Panel Board from Chassis Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 39
  • Intel SC5299DPNA | User Manual - Page 58
    letter "C") from the front panel board. A B C AF000432 Figure 47. Removing Front Panel Board from Chassis 8. Remove standoffs from old front panel and install on new front panel. TP02000 Figure 48. Removing Standoffs from Front Panel 40 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 59
    hand to align the front panel board in position inside the chassis. With your other hand, tighten the three screws to secure the front panel board to the front of the chassis. TP01740 Figure 50. Positioning Front Panel Board in Chassis Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 41
  • Intel SC5299DPNA | User Manual - Page 60
    . Reinstall the left side cover. For instructions, see "Installing the Left Side Cover" 14. Reconnect all peripheral devices and the AC power cable. Power up the server. Replacing a System Fan Caution: The system fan for the Intel® Entry Server Chassis SC5299-E is NOT hot swappable. Before removing
  • Intel SC5299DPNA | User Manual - Page 61
    and Upgrades 4. Remove the fan duct /system fan assembly. Figure 52. Removing Fan Duct / System Fan Assembly 5. Re-install the fan duct / system fan assembly. AF000284 TP01853 Figure 53. Re-installing Fan Duct / System Fan Assembly Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 43
  • Intel SC5299DPNA | User Manual - Page 62
    User Guide that came with your server board for connection location. 7. Install the left side cover. For instructions, see "Installing the Left Side Cover". 8. Plug all peripheral devices and the AC power cable into the server. Power up the server. Replacing a Fixed Power Supply Warning: Hazardous
  • Intel SC5299DPNA | User Manual - Page 63
    still in the open position. Make sure that the new fixed power supply rests on the small metal shelf on the side wall of the chassis (see letter "A" in the following figure). A Figure 56. Inserting Fixed Power Supply in Chassis Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide TP01753 45
  • Intel SC5299DPNA | User Manual - Page 64
    to the hard drive cage and connect power cables to installed devices. 13. Install the left side cover. For instructions, see "Installing the Left Side Cover". 14. Reconnect all peripheral devices and the AC power cable to the server. Power up the server. 46 Intel® Entry Server Chassis SC5299-E DP
  • Intel SC5299DPNA | User Manual - Page 65
    remove filler panel from chassis. . UP UP TP00916 Figure 58. Removing Power Supply Filler Panel 3. Insert new hot swap power supply module until it clicks into place. TP00917 Figure 59. Inserting Additional Hot Swap Power Supply Module Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 47
  • Intel SC5299DPNA | User Manual - Page 66
    Figure 60. Removing Hot Swap Power Supply Module from Chassis 4. Insert new hot swap power supply module. TP00854 Figure 61. Inserting Hot Swap Power Supply Module in Chassis 5. Connect power cable to replaced hot swap power supply. 48 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 67
    A TP01765 Figure 62. Removing Hot Swap Power Supply Module 5. Remove second (redundant) hot swap power supply module (or filler panel), if one is present. 6. Disconnect all internal power cables from chassis components and server board. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 49
  • Intel SC5299DPNA | User Manual - Page 68
    of the chassis. Note: You may have to work the power cables through slot sopenings with your free hand as you remove the power supply cage from the chassis. TP01762 Figure 64. Detaching Hot Swap Power Supply Cage from Rear of Chassis 50 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 69
    Rear Support Bracket from Hot Swap Power Supply Cage 10. Attach the rear support bracket to the new power supply cage with the two screws removed from the previous step. TP01763 Figure 66. Attaching Rear Support Bracket to Power Supply Cage Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 70
    . TP01766 Figure 67. Securing Hot Swap Power Supply Cage to Rear of Chassis 12. Secure inside panel of hot swap power supply cage to chassis with two screws. TP01767 Figure 68. Securing Hot Swap Power Supply Cage to Inside of Chassis 52 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 71
    69. Re-installing Hot Swap Power Supply Module(s) 18. Install the left side cover. For instructions, see "Installing the Left Side Cover". 19. Reconnect all peripheral devices and the AC power cable(s) to the server. Power up the server. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 53
  • Intel SC5299DPNA | User Manual - Page 72
    a Pedestal-configured Chassis Note: Do not install feet on your Intel® Entry Server Chassis SC5299-E if it is to be installed in a rack. Only install feet on a pedestal-configured chassis. 1. Observe the safety and ESD precautions listed in Appendix A, "Safety Information". 2. Power down the server
  • Intel SC5299DPNA | User Manual - Page 73
    six hot swap hard drives can be installed in the optional hot swap drive cage. Power requirements for each individual hard drive may limit the maximum number of drives that can be integrated into the server chassis. Note: The Intel® Entry Server Chassis SC5299-E does not support all hard drives. See
  • Intel SC5299DPNA | User Manual - Page 74
    71. Removing Fixed Drive Cage EMI Shield from Chassis 6. Disconnect cables from any fixed hard drives and remove hard drives from fixed hard drive cage. For instructions on removing fixed hard drives, see "Removing a Fixed Hard Drive". 56 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 75
    Drive Cage from Chassis 8. Gather together the components for the hot swap drive cage installation. You should have a hot swap drive cage with either a SAS/SATA or SCSI backplane, a side filler panel, a latch plate, a fan bracket, and a fan. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 76
    top of the hot swap drive cage. TP01135 Figure 73. Removing Stud Screws from Hot Swap Drive Cage 10. Attach the latch plate to the left side of the hot swap drive cage. TP01060 Figure 74. Attaching Latch Plate to Hot Swap Drive Cage 58 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 77
    of the hot swap drive cage. TP01059 Figure 75. Attaching Filler Panel to Hot Swap Drive Cage 12. Remove the two thumb screws that secure the backplane to the hot swap drive cage. TP01716 Figure 76. Removing Thumb Screws from Backplane Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 59
  • Intel SC5299DPNA | User Manual - Page 78
    slipped once the thumb screws were removed. Ensure that the backplane is positioned correctly before re-tightening the thumb screws. B A B TP01061 Figure 77. Attaching Fan Bracket to Hot Swap Drive Cage (SAS/SATA drive cage illustrated) 60 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 79
    fan bracket. Press the fan into the fan bracket until is clicks into place. Caution: Ensure that the label and directional airflow arrow on fan are pointed out (away from the backplane). TP01062 Figure 78. Attaching Fan to Fan Bracket Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 61
  • Intel SC5299DPNA | User Manual - Page 80
    board. TP02051 Figure 79. Inserting Hot Swap Drive Cage into Chassis 16. Connect fan cable to the appropriate connector on the server board. See your server board documentation for information on the location of the fan cable connector. 62 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 81
    iv. Connect the fan power to the server board. For the Intel® Server Board S5000VSA, use FAN1. For other Intel® server boards, refer to the Quick Start User's Guide that came with the server board. B C A TP02056 Figure 80. Cabling the SCSI Hot Swap Drive Cage Intel® Entry Server Chassis SC5299-E DP
  • Intel SC5299DPNA | User Manual - Page 82
    1 HDD 0 AB CD HDD 1 HDD 3 HDD 2 HDD 5 HDD 0 HDD 4 AF00450 A. Power cable B. Data Cable C. IPMB D. SES (not available in AXX6DRV3GEXP) Figure 81. Layout of Cable Connectors on the SAS/SATA Backplane (Backplane without expander shown) 64 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 83
    6-Drive HS NBoanck-epxlapnaender A D C HHDDDD HHDDDD 1 0 3 2 HHDDDD 5 4 B AF00449 Figure 82. Making Six-drive SAS/SATA Hot-Swap Drive Cage Backplane without Expander Connections (fan bracket not shown in the illustration for clarity) Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 84
    bezel assembly. For instructions, see "Installing the Front Bezel Assembly". 20. Install the left side cover. For instructions, see "Installing the Left Side Cover". 21. Plug all peripheral devices and the AC power cable into the server. 66 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 85
    with an optional hot swap SCSI or SAS/SATA hard drive cage. If you are replacing a fixed hard drive, see "Removing a Fixed Hard Drive" for instructions. Note: The Intel® Entry Server Chassis SC5299-E does not support all hard drives. See "Additional Information and Software"for an Internet link
  • Intel SC5299DPNA | User Manual - Page 86
    surface. 5. Set any jumpers and/or switches on the drive according to the drive manufacturer's instructions. 6. With the drive circuit-side down, position the connector end of the drive so that it is facing the rear of the drive carrier. 68 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 87
    lever until the lever begins to close by itself. Once the black drive carrier lever begins to close by itself, push on it to lock the drive carrier into place. AF000313 Figure 88. Re-installing Drive Carrier in Hot Swap Drive Cage Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 69
  • Intel SC5299DPNA | User Manual - Page 88
    Install Instructions (optional) 9. Close the drive bay access door. AF000314 Figure 89. Closing Drive Bay Access Door Removing a Hot-swap Hard Drive 1. Open the drive bay access door. AF000311 Figure 90. Opening Drive Bay Access Door 70 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 89
    from Hot Swap Drive Cage 3. Remove the four screws that attach the hard drive to the drive carrier. Lift the drive from the carrier. Store the old drive in an anti-static bag. TP01714 Figure 92. Removing Hard Drive from Drive Carrier Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 71
  • Intel SC5299DPNA | User Manual - Page 90
    into the chassis. The green latch must be to the left. Do not push on the black lever until the lever begins to close by itself. When the black lever begins to close by itself, push on it to lock the drive carrier into place. 72 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 91
    must be replaced in the chassis, even if no hard drive is installed in it. AF000313 Figure 95. Re-installing Drive Carrier in Hot Swap Drive Cage 6. Close the drive bay access door. AF000314 Figure 96. Closing Drive Bay Access Door Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 73
  • Intel SC5299DPNA | User Manual - Page 92
    Hot Swap Drive Cage Upgrade Install Instructions (optional) 74 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 93
    Mount Kit Install Instructions (optional) The Intel® Entry Server Chassis SC5299-E can be configured as a rack-mount chassis when outfitted with the optional rack mount accessory kit. Before You Begin Before working with your server product, review the important safety information listed in Appendix
  • Intel SC5299DPNA | User Manual - Page 94
    feet. B A TP01710 Figure 97. Removing Chassis Feet 5. Remove the top side cover by pressing the latch and pushing back on the side cover to slide rearward and lift from chassis. TP00958 Figure 98. Removing Top Side Cover from Chassis 76 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 95
    Kit Install Instructions (optional) 6. Remove any PCI add-in boards. Remove the PCI card guide by pressing in on the blue tabs (see letter "A" in the following figure) and pulling the PCI card guide outward (see letter "B"). A B TP02001 Figure 99. Removing PCI Card Guide Intel® Entry Server Chassis
  • Intel SC5299DPNA | User Manual - Page 96
    plastic filler panel from chassis by pushing on interior tab (see letter "A" in the following figure) and sliding filler panel towards rear of chassis (see letter "B"). B A AF000285 Figure 100. Removing Plastic Filler Panel from Chassis 78 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 97
    Install Instructions (optional) 8. Remove the three plastic plugs from left side of chassis. AF000286 Figure 101. Removing Plastic Plugs 9. Remove two screws from left and right sides of chassis. AF000287 Figure 102. Removing Rear Screws Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 98
    Instructions (optional) 10. Remove four plastic plugs from top side cover. TP02004 Figure 103. Removing Plastic Plugs from Top Side Cover 11. Install rack handle on left side cover using four 6-32 screws. TP01053 Figure 104. Installing Rack Handle on Left Side Cover 80 Intel® Entry Server Chassis
  • Intel SC5299DPNA | User Manual - Page 99
    105. Affixing Label to Front Panel 13. Install top side cover on chassis. Warning: This chassis must be operated with the left side cover installed to ensure proper cooling. TP01057 Figure 106. Installing Top Side Cover on Chassis Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 81
  • Intel SC5299DPNA | User Manual - Page 100
    Kit Install Instructions (optional) 14. Detach inner rack rail from rack rail assembly. Press tab on inside of rack rail to release rack rail from rack rail assembly. TP02006 Figure 107. Detaching Inner Rack Rail from Rack Rail Assembly 82 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 101
    to Chassis 16. Attach outer rack rails to rack uprights. Ensure that the screws (two per outer rack rail; see letter "A" in the following figure) pass through the rack upright (see letter "B"), and the outer rack rail (see letter "C"). Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 83
  • Intel SC5299DPNA | User Manual - Page 102
    Rack Mount Kit Install Instructions (optional) C A B TP01056 Figure 109. Attaching Outer Rack Rails to Rack Uprights 84 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 103
    this system requires TWO people. WARNING: Safe handling of this system requires TWO people. TP01058 Figure 110. Installing Chassis into Rack 18. Reconnect all peripheral devices and the AC power cable to the server. Power up the server. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 85
  • Intel SC5299DPNA | User Manual - Page 104
    Rack Mount Kit Install Instructions (optional) 86 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 105
    are pinched and that the airflow from the fans is not blocked. Power Supply Specifications The power supply specifications for your Intel® Entry Server Chassis SC5299-E will depend upon the configuration of chassis you purchased. Four power supply configurations are available: • 550-W PFC fixed
  • Intel SC5299DPNA | User Manual - Page 106
    that your loads do not exceed the combined total wattage of 650 Watts. Table 6. 650-W Power Supply Output Capability Voltage Maximum Current +3.3 V +5.0 V +5 V Standby -12.0 V 12 V1 12 V2 12 V3 24 A 30 A 3.0 A 0.3 A 16 A 16 A 16 A 88 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 107
    Technical Reference Table 6. 650-W Power Supply Output Capability Voltage Maximum Current 12 V4 12 V5 16 A 18 A System LWA typical operation Electrostatic Tested to 15 kilovolts (kV); no component damage. discharge (ESD) Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 89
  • Intel SC5299DPNA | User Manual - Page 108
    Technical Reference 90 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 109
    or death if safety instructions are not followed. Indicates hot components or surfaces. Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 91
  • Intel SC5299DPNA | User Manual - Page 110
    power, 5V standby power is active whenever the system is plugged in. To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are 92 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 111
    AC cord is required for each system power supply. Some power supplies in Intel® servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing. The power supply in this product contains no user-serviceable parts. Do not open the
  • Intel SC5299DPNA | User Manual - Page 112
    the fan guard in place. Rack Mount Warnings The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from it. The equipment rack must be installed according to the rack manufacturer's instructions. Install equipment
  • Intel SC5299DPNA | User Manual - Page 113
    problems. For proper cooling and airflow, operate the system only with the chassis covers installed installed. • Attach the covers to the chassis according to the product instructions. serviceable • Return to manufacturer for servicing Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 95
  • Intel SC5299DPNA | User Manual - Page 114
    Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripherieger der Netzspannung zu trennen. Bereiten Sie bitte Batterie auf 96 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 115
    Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 97
  • Intel SC5299DPNA | User Manual - Page 116
    vom Stromnetz. Die Steckdose muß in der Nähe der Anlage angebracht und gut erreichbar sein. • Netzkabel müssen an eine ordnungsgemäß geerdete Steckdose angeschlossen sein. 98 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 117
    . Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. • Schalten Sie den Server aus, und ziehen Sie alle Netzkabel ab, bevor Sie Komponenten ein- oder ausbauen, die nicht es nicht ohne diese Abdeckung betrieben werden. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 99
  • Intel SC5299DPNA | User Manual - Page 118
    ein Server oder andere Geräte herausgezogen werden. Bei der Installation des Racks müssen die Anweisungen des Rack-Herstellers beachtet werden. Gehen Sie bei der Installation von Geräten im Rack immer die Platine nicht über eine Fläche. 100 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 119
    oder Laser- Komponenten. • Laser-Peripheriegeräte oder -Komponenten besitzen keine für den Benutzer wartungsbedürftigen Teile. • Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 101
  • Intel SC5299DPNA | User Manual - Page 120
    aux cartes serveur Intel®, au châssis de serveur Intel® (sur pieds et sur rack) et aux périphériques installés. Pour réduire Vous devez suivre les informations de ce guide et les instructions d'assemblage des manuels de serveur pour vé 102 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 121
    Ce produit a été testé comme équipement informatique (ITE) et peut être installé dans des bureaux, des écoles, des salles informatiques et des endroits commerciaux de faciliter la manipulation, retirez tout composant amovible. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 103
  • Intel SC5299DPNA | User Manual - Page 122
    cordons d'alimentation doivent répondre aux critères suivants : • Le cordon d'alimentation doit supporter une intensité supérieure à celle indiquée sur le produit. • Le cordon d'alimentation électriques correctement reliées à la terre. 104 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 123
    du serveur. Attention: Si le serveur a été utilisé, les processeurs et dissipateurs de chaleur installés peuvent être chauds. À moins que vous n'ajoutiez ou ne retiriez un composant connectable à me en route sans la protection en place. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 105
  • Intel SC5299DPNA | User Manual - Page 124
    . Utilisez si possible un tapi de mousse conducteru, mais pas l'emballage de la carte. Veillez à ce que la carte ne glisse sur aucune surface. 106 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 125
    les cartes d'extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. Périphériques laser Attention: Pour é • Retournez-les au fabricant en cas de problème. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 107
  • Intel SC5299DPNA | User Manual - Page 126
    tarjetas de servidor de Intel®, las carcasas de servidor de Intel® (montaje en bastidor y en pedestal) y los dispositivos perif guía y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cumplimiento con las Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 127
    sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 109
  • Intel SC5299DPNA | User Manual - Page 128
    ón en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use de forma inmediata con el fin de desconectarlos. 110 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 129
    se le ha suministrado con una protección para el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 111
  • Intel SC5299DPNA | User Manual - Page 130
    mismo. El bastidor del equipo debe instalarse siguiendo las instrucciones del fabricante del bastidor. Instale el equipo en el bastidor comenzando desde la parte de abajo, con el equipo más deslice la tarjeta sobre ninguna superficie. 112 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 131
    caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 113
  • Intel SC5299DPNA | User Manual - Page 132
    Safety Information 简体中文 Intel Intel Intel Web UL 注意 警告 114 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 133
    Safety Information ITE ITE 场地选择 注意事项 5V Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 115
  • Intel SC5299DPNA | User Manual - Page 134
    Safety Information 116 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 135
    Safety Information ESD) ESD ESD ESD ESD Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 117
  • Intel SC5299DPNA | User Manual - Page 136
    Safety Information 其他危险 替换电池 118 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 137
    B Installation/Assembly Safety Instructions English The power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel. Do not attempt to modify or use the supplied AC power cord if it is not the exact type required. A product with more than one power
  • Intel SC5299DPNA | User Manual - Page 138
    lines to your modem during an electrical storm. • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. 120 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 139
    Deutsch Installation/Assembly Safety Instructions Benutzer können am Netzgerät dieses Produkts keine Reparaturen vornehmen. Das Produkt enthält zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 121
  • Intel SC5299DPNA | User Manual - Page 140
    Installation/Assembly Safety Instructions SICHERHEISMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. 122 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 141
    Installation/Assembly Safety Instructions Das System wurde für den Betrieb in einer normalen Büroumgebung entwickelt. Der Standort sollte: • " ährleisten, da der Stromanschluß des Produkts hauptsächlich über die Kabel unterbrochen wird Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 123
  • Intel SC5299DPNA | User Manual - Page 142
    Installation/Assembly Safety Instructions Français Le bloc d' installé sur à l'arrière du système, déverrouillez-le et retirez-le. 2. Retirez toutes les vis des panneaux et mettez-les dans un endroit sûr. 3. Retirez les panneaux. 124 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 143
    à la terre. • "Suffisamment spacieux pour vous permettre d'accéder aux câbles d'alimentation (ceux-ci étant le seul moyen de mettre le système hors tension). Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 125
  • Intel SC5299DPNA | User Manual - Page 144
    Installation/Assembly Safety Instructions Español El usuario debe abstenerse de manipular los componentes de la fuente de alimentación de se ha instalado uno. 2. Extraiga y guarde todos los tornillos de las tapas.Extraiga las tapas. 126 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 145
    Installation/Assembly Safety Instructions Para obtener un enfriamiento y un flujo de aire adecuados, reinstale siempre las tapas del acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 127
  • Intel SC5299DPNA | User Manual - Page 146
    Installation/Assembly Safety Instructions Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell'alimentazione di e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. 128 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 147
    Installation/Assembly Safety Instructions Per il giusto flusso dell'aria e raffreddamento del sistema, rimettere sempre le ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 129
  • Intel SC5299DPNA | User Manual - Page 148
    Installation/Assembly Safety Instructions 130 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 149
    C Getting Help World Wide Web http://support.intel.com/support/motherboards/server/chassis/sc5299-e/. Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for
  • Intel SC5299DPNA | User Manual - Page 150
    621 33104691 (not toll-free) Hong Kong 852 2 844 4456 India........... 0006517 2 68303634 (manual toll-free. You need an IDD-equipped telephone) Indonesia ... 803 65 7249 Korea ......... 822 767 288. Once connected, dial 800 843 4481 132 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 151
    0114 Peru 001 916 377 0114 Uruguay..... 001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 133
  • Intel SC5299DPNA | User Manual - Page 152
    Getting Help 134 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 153
    at http:// support.intel.com/support/motherboards/server/chassis/sc5299-e/. For the fastest service, please submit your form via the Internet. Date Submitted Company Name Contact Name Email Address Intel Server Product Priority (Critical, Hot, High, Low Brief Problem Description. Provide
  • Intel SC5299DPNA | User Manual - Page 154
    and Vendor / part number Operating System Information Operating System Version Service Pack Add-in Card, Peripheral, Video, NIC Check each NIC On-Board NIC1 Description Driver Revision IRQ I/O Base FW Address Revision 136 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 155
    X Peripheral On-board NIC2 Description Hard Drive Information X Drive Type (SCSI, SATA, etc) Make/Model Intel® Server Issue Report Form Driver Revision IRQ I/O Base FW Address Revision Hot-swap or Fixed IRQ FW Revision Management Information On-board Platform Instrumentation only
  • Intel SC5299DPNA | User Manual - Page 156
    Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done 138 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 157
    does not cover damages due to external causes, including accident, problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration, repair, improper installation, or improper testing. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 139
  • Intel SC5299DPNA | User Manual - Page 158
    repair for the product, please go to the following Web site to obtain instructions: http://support.intel.com/support/ motherboards/draform.htm • In Europe and in Asia Contact your original authorized distributor for warranty service. 140 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 159
    .intel.com/), call your local distributor or an Intel Customer Support representative. See "Getting Help" for telephone numbers. Returning a Defective Product Before returning any product, call your authorized dealer/distribution authority. Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 160
    Warranty 142 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 161
    compliance, you must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing before computer integration, make sure that the chassis, power supply, and other modules have passed EMC testing using a server board with a microprocessor from the same family
  • Intel SC5299DPNA | User Manual - Page 162
    server chassis has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® Conformity (CENELEC Europe) • FCC/ICES-003 Class A Attestation (USA/Canada) 144 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 163
    • Ecology Declaration (International) Product Regulatory Compliance Markings This Intel® server chassis product bears the following regulatory marks. Table 8. Product A) USA EMC Marking (Class A) Canada VCCI Marking (Class A) Japan Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 145
  • Intel SC5299DPNA | User Manual - Page 164
    installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 146 Intel® Entry Server Chassis
  • Intel SC5299DPNA | User Manual - Page 165
    Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance. VCCI (Japan) Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide 147
  • Intel SC5299DPNA | User Manual - Page 166
    , it may cause radio interference. Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder 148 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • Intel SC5299DPNA | User Manual - Page 167
    Compliance Information If you do not have access to Intel's Web address, please contact your local Intel representative. • Server Chassis: (base chassis is provided with power supply and fans) - UL listed. • Server board: you must use an Intel server board - UL recognized. • Add-in boards: must have
  • Intel SC5299DPNA | User Manual - Page 168
    Regulatory and Compliance Information 150 Intel® Entry Server Chassis SC5299-E DP/WS/BRP User Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

Intel® Entry Server Chassis SC5299-E
DP/WS/BRP User Guide
A Guide for Technically Qualified Assemblers of Intel
®
Identified Subassemblies/Products
Intel Order Number D37596-002