Intel SR1325TP1 User Guide

Intel SR1325TP1 - Entry Server Platform Manual

Intel SR1325TP1 manual content summary:

  • Intel SR1325TP1 | User Guide - Page 1
    Intel® Entry Server Platform SR1325TP1-E User Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Order Number: C61602-001
  • Intel SR1325TP1 | User Guide - Page 2
    be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or nonoperating limits. Intel, Intel Pentium, and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States
  • Intel SR1325TP1 | User Guide - Page 3
    list of accessories or other components you may need, troubleshooting information, and instructions on how to add and replace components on the Intel Entry Server Platform SR1325TP1-E. For the latest version of this manual, refer to http://www.support.intel.com/support/motherboards/server/SR1325TP1
  • Intel SR1325TP1 | User Guide - Page 4
    and installing a processor. See the Intel Server Platform SR1325TP1-E Quick Start User's Guide for initial installation instructions. Product Accessories You may need or want to purchase one or more of the following accessory items for your server: ƒ One Intel® Pentium® 4 processor with at least
  • Intel SR1325TP1 | User Guide - Page 5
    or information about the accessories that can be used with this server platform, go to http://www.support.intel.com/support/motherboards/server/SR1325TP1-E/index.htm ƒ In-depth technical information about the server board included with this server platform, including BIOS settings and chipset
  • Intel SR1325TP1 | User Guide - Page 6
    to chassis ground any unpainted metal surface on your server when handling parts. ESD and handling boards: Always handle boards carefully. the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with,
  • Intel SR1325TP1 | User Guide - Page 7
    safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://www.support.intel.com/support/motherboards/server. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warn- und
  • Intel SR1325TP1 | User Guide - Page 8
    Preface viii
  • Intel SR1325TP1 | User Guide - Page 9
    Chassis Components 19 Server Chassis Front Panel 20 Server Chassis Back Panel 21 Server Chassis Peripherals 21 Hard Disk Drives ...22 Floppy / CD-ROM / DVD-ROM Slimline Bay 22 Power Supply ...22 System Cooling ...23 Chassis Security ...23 Hardware Requirements ...23 2 Platform Installations and
  • Intel SR1325TP1 | User Guide - Page 10
    not Recognized under Device Manager (Windows* Operating System).. 71 Hard Drive(s) are not Recognized 71 Bootable CD-ROM Is Not Detected 71 LED Information ...72 BIOS Error Messages ...73 BIOS POST Beep Codes 74 x Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 11
    Contents BIOS Recovery Beep Codes Intel® Server Issue Report Form 83 Warranty...87 Limited Warranty for Intel® Chassis Subassembly Products 87 Extent of Limited Warranty...87 Warranty Limitations and Exclusions 88 Limitations of Liability 88 How to Obtain Warranty Service 89 Telephone Support
  • Intel SR1325TP1 | User Guide - Page 12
    the Cover 26 Figure 9. Installing Chassis Cover 27 Figure 10. Removing Processor Air Duct 28 Figure 11. Installing Processor Air Duct 29 Figure 12. Installing Memory DIMMs 30 Figure 13. Board 52 Figure 37. Replacing the Battery 54 xii Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 13
    5. Table 6. Table 7. Table 8. Table 9. Table 10. Server Board Features 15 Configuration Jumper [J1D1 17 NIC LEDs...18 Control Button Functions 20 LED Indicator Status 20 Keyboard Commands 57 BIOS Error Messages 73 Beep Codes...74 BIOS Recovery Beep Codes 75 Product Certification Markings 78
  • Intel SR1325TP1 | User Guide - Page 14
    Contents xiv Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 15
    main features of the Intel® Entry Server Platform SR1325TP1-E. Table 1 summarizes the major features of the Intel® Server Board SE7210TP1-E that is used in this platform. Table 1. Server Board Features Feature Processors Description Support for an Intel® Pentium® 4 processor in an mPGA478 package
  • Intel SR1325TP1 | User Guide - Page 16
    Swap Backplane Connector CC. SCSI LED Header DD. SATA 1 Connector EE. SATA 2 Connector FF. System Fan 6 Header GG. System Fan 5 Header HH. Jumper Block Figure 1. Intel Server Board SE7210TP1-E Diagram Intel® Entry Server Platform SR1325TP1-E User Guide 16
  • Intel SR1325TP1 | User Guide - Page 17
    Server Platform Features Configuration Jumpers J1D1 15 14 13 11 10 9 765 3 21 11 for normal operation and for normal BIOS operational updates. BIOS Recovery 14-15 If these pins are jumpered, the system will attempt to recover the BIOS by loading the BIOS code into the flash device from
  • Intel SR1325TP1 | User Guide - Page 18
    Server Platform Features Server Board Back Panel Connectors AB C D EF TP00652 A. USB 1, 2, 3 B. Keyboard/Mouse C. Serial port A D. Video E. NIC1 (1Gbit) F. (if left LED is on or blinking) 100 Mbps connection 1000 Mbps connection Intel® Entry Server Platform SR1325TP1-E User Guide 18
  • Intel SR1325TP1 | User Guide - Page 19
    Server Platform Features Server Chassis Components I J A B C D E A. Hard Disk Drive 1 (drive purchased separately) B. Hard Disk Drive G F F. Front Fan Module G. Power Supply H. Power Supply Fans TP00578 I. Server Board SE7210TP1-E J. Chassis Intrusion Switch Figure 4. System Components 19
  • Intel SR1325TP1 | User Guide - Page 20
    , an Intelligent Platform Management Interface (IPMI)-based satellite management controller must send a Set Fault Indication command to the mini Baseboard Management Controller (mBMC). 3 Off when the system is powered off or in a sleep state. Intel® Entry Server Platform SR1325TP1-E User Guide 20
  • Intel SR1325TP1 | User Guide - Page 21
    Server Platform Features Server Chassis Back Panel C I A DE B A. AC Power Xonnector B. USB Ports 1, 2, 3 C. Keyboard Connector D. Mouse Connector E. Serial Port A F H G TP00577 F. Video Connector G. NIC1 Connecgtor (1 Gbit) H. NIC2 Connector (10/100 Mbit) I. PCI Card Bracket (full height
  • Intel SR1325TP1 | User Guide - Page 22
    ✏ NOTE The Intel Entry Server Platform SR1325TP1-E does not support all floppy, CD-ROM or DVD-ROM drives. You must order the appropriate accessory kit to install one of these drives. For accessory kit information, see http://support.intel.com/support/motherboards/server/SR1325TP1-E Power Supply The
  • Intel SR1325TP1 | User Guide - Page 23
    Server Platform Features System Cooling The chassis includes five front fans for cooling the processor, hard drives, and PCI cards. These fans are not hot-swappable. To replace the front fan module, you must first take the server out of service, turn off all peripheral devices connected to the
  • Intel SR1325TP1 | User Guide - Page 24
    specifications, the board should be populated with DIMMs that support the Serial Presence Detect (SPD) data structure. This allows the BIOS to read the SPD data and program the chipset DIMMs are used, ECC will be disabled and will not function. Intel® Entry Server Platform SR1325TP1-E User Guide 24
  • Intel SR1325TP1 | User Guide - Page 25
    Upgrades 2 Platform Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the safety instructions at the beginning of this manual. Tools as it would be positioned for normal operation. Intel® Entry Server Platform SR1325TP1-E User Guide 25
  • Intel SR1325TP1 | User Guide - Page 26
    Platform Installations and Upgrades Removing and Installing the Chassis Cover Removing the Chassis Cover ✏ NOTE A nonskid surface or a it stops. 3. Lift the cover straight up to remove it from the chassis. Figure 8. Removing the Cover TP00580 26 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 27
    Platform Installations and Upgrades Installing the Chassis Cover 1. Place the cover over the chassis so that the side edges of the cover sit just inside the
  • Intel SR1325TP1 | User Guide - Page 28
    air duct. See letter "A" in Figure 10. 2. Disconnect the main power cable. See letter "B" in the figure below. 3. Lift the air duct from the server chassis. See letter "C" in the figure. A C B Figure 10. Removing Processor Air Duct TP00613 28 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 29
    Platform Installations and Upgrades Installing the Processor Air Duct 1. Place the processor air duct over the processor socket and DIMMs, using caution to make sure you do not the cable as demonstrated by letter "C" in the figure below. B A C Figure 11. Installing Processor Air Duct TP00579 29
  • Intel SR1325TP1 | User Guide - Page 30
    server. Turn off the server. 3. Disconnect the AC power cord. 4. Remove the chassis cover and locate the DIMM sockets (see Figure 12). 5. Remove the processor air duct that covers the processor and partially obscures the DIMMs. For instructions 30 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 31
    server. 4. Remove the chassis cover and locate the DIMM(s). See Figure 13. 5. Remove the processor air duct that covers the processor and partially obscures the DIMMs. For instructions on removing the air duct, see "Removing the Processor any parts you removed or disconnected to reach the DIMM
  • Intel SR1325TP1 | User Guide - Page 32
    the pins of the processor with the socket, insert the processor into the socket. See letter B in the figure below 5. Close the handle completely. See letter C. A B C TP00519 Figure 14. Installing the Processor in the Processor Socket 32 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 33
    Platform Installations and Upgrades ✏ NOTE The bottom of the heat sink may have thermal interface material to the top of the processor. 6. Place the fan heat sink on top of the processor. See Figure 15. TP00520 Figure 15. Attaching the Heat Sink to the Processor 7. Fully open the levers at the top
  • Intel SR1325TP1 | User Guide - Page 34
    the Processor Fan Cable to the Processor Fan Connector 11. Install the processor air duct. The air duct must be in place for proper system cooling. For instructions on installing the processor air duct, see "Installing the Processor Air Duct." 34 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 35
    the Intel Entry Server Platform SR1325TP1-E are not hot-swappable. CAUTION The Intel Entry Server Platform SR1325TP1-E does not support all hard drives. To see a list of validated manufacturers and hard drive types, go to: http://support.intel.com/support/motherboards/server/SR1325TP1-E Installing
  • Intel SR1325TP1 | User Guide - Page 36
    drive bracket and insert four screws from the fastener bag marked "A" to secure the drive to the bracket. The fastener bag was included with your server platform. B A TP00429 Figure 20. Attaching a Hard Disk Drive to a Bracket 36 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 37
    Platform Installations and Upgrades 7. Set the drive assembly on the bottom of Installing Third Hard Drive (optional accessory kit) As an option, you can install a third hard drive into your chassis. For instructions on installing this drive, refer to the instructions included with the third hard
  • Intel SR1325TP1 | User Guide - Page 38
    the installation instructions that are included server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. 38 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 39
    Platform Installations and Upgrades Removing Drive Cage from Chassis 1. Before removing the cover to work inside the system, observe the safety guidelines at the beginning of
  • Intel SR1325TP1 | User Guide - Page 40
    Platform Installations and Upgrades Removing Backplane Board and Cage Cover 1. Remove the three screws that attach the backplane board to the FFC from the floppy drive. See letter "A" in Figure 24. Leave the FFC attached to the backplane board. 40 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 41
    Platform Installations and Upgrades Reattaching Flat Flex Cable to Backplane Board The Flat Flex Cable (FFC) is used only when a floppy drive is installed into the
  • Intel SR1325TP1 | User Guide - Page 42
    Platform Installations and Upgrades Inserting Replacement Floppy Drive 1. Turn the cage so that the metal flange at the side of the drive extends the silkscreen label "IDE CONN" is at the top left and the FFC is at the right. See Figure 26, B. 42 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 43
    Platform Installations and Upgrades ✏ NOTE If the FFC is not attached to the backplane board, see "Reattaching Flat Flex Cable to Backplane Board" for instructions on reinstalling it. Install the FFC into the backplane board before attaching it to the floppy drive. 7. Pull down gently on the FFC
  • Intel SR1325TP1 | User Guide - Page 44
    Platform Installations and Upgrades Inserting Replacement CD-ROM / DVD-ROM Drive 1. Turn the cage so that the metal flange at the side of the cage (two screws on each side). TP00143D Figure 27. Installing Replacement CD-ROM or DVD-ROM Drive 44 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 45
    Platform Installations and Upgrades Attach Backplane to Cage 1. If a floppy drive is installed, hold the backplane board so the silkscreen label "IDE CONN" is at the
  • Intel SR1325TP1 | User Guide - Page 46
    5. Pull the PCI card out of the riser card slot. 6. Install the new PCI add-in card on the riser. 7. Insert the riser card connector in the server board slot while aligning the tabs on the rear retention bracket with the holes in the chassis. 46 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 47
    Tipping it in the slot while installing it or pressing on the PCI card may damage the riser card, board slot, or the PCI card. 8. Firmly press the riser card straight down until it is seated in the server board slot. 9. Replace the screw that attaches the riser assembly to the chassis. B A B Figure
  • Intel SR1325TP1 | User Guide - Page 48
    Platform Installations and Upgrades Replacing the Power Supply CAUTION Your server does not have a redundant power supply. Before replacing the power supply, you must take the server out of service Figure 32. Removing the Power Supply TP00587 48 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 49
    Platform Installations and Upgrades 8. Set the replacement power supply onto the chassis at the front of the power supply. See letter "A" in Figure 33. 12. Connect the power cables to the server board and the drives. 13. Replace the chassis cover. 14. Plug the power cord back into the power supply
  • Intel SR1325TP1 | User Guide - Page 50
    cable. 5. Disconnect the front fan cables from the server board. 6. Remove the three screws that attach the front fan module to the chassis. 7. Lift the fan module from the chassis. See Figure 34. Figure 34. Removing the Front Fan Module 50 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 51
    Platform Installations and Upgrades 8. Install the replacement fan module into the chassis using the three screws that held the original fan module in place. 9. Reattach the chassis intrusion cable. 10. Reconnect the cable from each fan at the appropriate location on the server board. Fans are
  • Intel SR1325TP1 | User Guide - Page 52
    front panel board to the chassis with the two screws removed from the old front panel board. 6. Plug the cable from the server board back into the front panel board. 7. Replace the chassis cover. Figure 36. Replacing the Front Panel Board 52 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 53
    absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer service representative or dealer for a list of approved devices. WARNING Danger of explosion if battery
  • Intel SR1325TP1 | User Guide - Page 54
    the configuration settings to the RTC. Installing or Replacing the Power Cord ✏ NOTE If you will be placing your server in a rack, wait to install the power cord until after the server is in the rack. Plug the power cord into the power supply. 54 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 55
    Guide ✏ NOTES Although these documents do not refer specifically to the Intel® Entry Server Platform SR1325TP1-E, the instructions in these documents are correct for this platform. The rail kit does not provide enough screws to mount the server chassis into a rack. Your Intel Entry Server Platform
  • Intel SR1325TP1 | User Guide - Page 56
    problems in your server. In a 3GHz system, the temperature cannot rise above 30°C (86 °F) Ventilation: The equipment rack must provide sufficient airflow to the front of the server into a large error calculating air conditioning capacity. 56 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 57
    Server Utilities 3 Server Utilities Table 6. Press F5/F6/+ Keyboard Commands Description Help - Pressing F1 the user is returned to where they were before F10 was pressed without affecting any existing values. Intel® Entry Server Platform SR1325TP1-E User Guide 57
  • Intel SR1325TP1 | User Guide - Page 58
    . Review also any release notes in the release notes file that accompanies the new version of the BIOS. The release notes may contain critical information regarding jumper settings, specific fixes, or other information to complete the upgrade. 58 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 59
    Server Utilities Creating a Bootable Diskette Use a DOS system to create the diskette as follows: says "Completed Successfully." The system will then reboot. 4. If you selected option 2, to manually update the BIOS or to update the flash memory, you can either select "Update Flash Memory From a File
  • Intel SR1325TP1 | User Guide - Page 60
    : automatically with the crisis recovery diskette, and manually by moving a jumper on the system board. These methods are described below. ✏ NOTE BIOS recovery is the mode of last resort, used only when the main system BIOS will not come up. 60 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 61
    Server Utilities Recovering the BIOS with the Crisis Recovery Diskette Manually Recovering the BIOS A BIOS recovery can be manually initiated. This option would be used only when the BIOS is corrupt, but the ROM checksum error does not occur during POST. To manually initiate a BIOS recovery, use the
  • Intel SR1325TP1 | User Guide - Page 62
    system begins beeping, power it down and disconnect the AC power. 6. Return the CMOS Clear jumper to the original location, covering pins 1 and 2. 7. Close the server chassis, reconnect the AC power and power up the system. 62 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 63
    in the proper location and not touching any components, causing a potential short? ‰ Are all add-in PCI boards fully seated in their slots on the server board? ‰ Are all jumper settings on the server board correct? Intel® Entry Server Platform SR1325TP1-E User Guide 63
  • Intel SR1325TP1 | User Guide - Page 64
    Troubleshooting or configured? ‰ Are all device drivers properly installed? ‰ Are the configuration settings chassis lists, as well as the supported hardware and operating system list. See to identifying a hardware problem and locating its source. Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 65
    Troubleshooting and steps to take to correct the problem. Confirming Loading of the Operating System Problems and Corrective Actions This section provides possible solutions for these specific problems activity light does not light. ƒ There are problems with application software. ƒ The bootable CD-ROM
  • Intel SR1325TP1 | User Guide - Page 66
    . ‰ Remove the memory DIMMs and re-seat them. ‰ Make sure the processor(s) comply with the system requirements. ‰ Make sure the processor(s) have been populated according to the system requirements. ‰ Remove the processor(s) and re-seat them. 66 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 67
    Troubleshooting If you are using an add-in video controller board, do the following: 1. Verify that the video works using the onboard video controller. 2. Verify that the video controller board is fully seated in the server may have failed. Contact your service representative or authorized dealer for
  • Intel SR1325TP1 | User Guide - Page 68
    the BIOS setup drivers. See "Additional Information and Software" for a link to the current drivers. ‰ Make sure the driver servers (without a hub), you will need a crossover cable. ‰ Check the network controller LEDs next to the NIC connectors. 68 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 69
    Troubleshooting Problems with Network The server hangs when the drivers are loaded. ‰ Certain drivers may require interrupts that are not shared with other PCI drivers. For these drivers, it may be necessary to alter settings so that interrupts are not shared. See the documentation that came with
  • Intel SR1325TP1 | User Guide - Page 70
    correct device drivers installed. If the problems persist, contact the software vendor's customer service representative. Problems with Application Software that Ran Correctly Earlier Problems that occur power outlet and the system power cord. 70 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 71
    Troubleshooting Devices are not Recognized under Device Manager (Windows* Operating System) The Windows* operating systems do not include all of the drivers for the Intel® chipsets, onboard NICs, and other components. See "Additional Information and Software" for a link to the current drivers and
  • Intel SR1325TP1 | User Guide - Page 72
    Intel® Server Board SE7210TP1-E includes LEDs that can aid in troubleshooting your system. A table of these LEDs with a description of their use is listed below. LED Name ID System fault Function Aid in server 1" behind processor socket Front left Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 73
    Troubleshooting BIOS Error Messages When a recoverable error occurs during the POST, the BIOS displays an error message describing the problem (see Table 7). Table 7. BIOS Error Messages Error Message GA20 Error Explanation An error occurred with Gate A20 when switching to protected mode during
  • Intel SR1325TP1 | User Guide - Page 74
    problem supported by BIOS beep codes. Table 8. Beep Codes Number of Beeps Description 1 Refresh failure 2 Parity cannot be reset 3 First 64 Kb memory failure 4 Timer not operational 5 Processor BIOS (such as, POST module not found) 74 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 75
    and two short beeps: Insert the BIOS recovery diskette. An error or warning condition at boot can result in a series of beeps being issued known as "beep codes." These beeps have a code that identifies system or PCI card events. For example, some Intel® RAID controller cards have beep codes. Before
  • Intel SR1325TP1 | User Guide - Page 76
    Troubleshooting 76 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 77
    ® host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative. ƒ FCC (Class A Verification) - Radiated & Conducted Emissions (USA) ƒ ICES-003 (Class A) - Radiated & Conducted Emissions (Canada) ƒ CISPR 22, 3rd Edition
  • Intel SR1325TP1 | User Guide - Page 78
    RRL MIC Mark Electromagnetic Compatibility Notices FCC (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124 1-800-628-8686 78 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 79
    comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
  • Intel SR1325TP1 | User Guide - Page 80
    : Intel 4. Date of Manufacturer: Marked on Product 5. Manufacturer / Nation : Intel Australia / New Zealand This product has been tested and complies with AS/NZS 3548. The product has been marked with the C-Tick mark to illustrate compliance. 80 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 81
    Help Getting Help World Wide Web http://support.intel.com/support/motherboards/server/SR1325TP1-E Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing
  • Intel SR1325TP1 | User Guide - Page 82
    Getting Help 82 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 83
    Stepping/Spec: System BIOS Version: HSC Firmware Version: Chassis Model ˆ Intel SR1325-E DIMM Configuration DIMM1A MB: DIMM1A Vendor/part number: DIMM1B MB: DIMM1B Vendor/part number: DIMM2A MB: DIMM2A Vendor/part number: DIMM2B MB: DIMM2B Vendor/part number: Intel® Entry Server Platform SR1325TP1
  • Intel SR1325TP1 | User Guide - Page 84
    Mb) Driver Revision IRQ # I/O Base Address FW Rev# Hard Drive Information: ˆ IDE # of drives installed: Make/Model/Firmware Revision ˆ SCSI # of drives installed: Make/Model/Firmware Revision ˆ SATA # of drives installed: Make/Model/Firmware Revision 84 Intel® Entry Server Platform SR1325TP1
  • Intel SR1325TP1 | User Guide - Page 85
    Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done. Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 86
    Server Issue Report Form 86 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 87
    an Intel authorized distributor. Software of any kind delivered with or as part of problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration, repair, improper installation, or improper testing. Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 88
    an implied warranty lasts, so this limitation may not apply to you. Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, , the English language version shall control. 88 Intel® Entry Server Platform SR1325TP1-E User Guide
  • Intel SR1325TP1 | User Guide - Page 89
    2 27189915 1800-801390 0800-444365 803-65-7249 800-6310003 IDD call +63(2)6368416 (0006517) 830-3634 Manual toll free. From India, you need an IDD-equipped phone. IDD call +63(2)6368415 Oct-April: 6:00-16:00 April-Oct: 5:00-16:00 Pakistan Intel® Entry Server Platform SR1325TP1-E User Guide 89
  • Intel SR1325TP1 | User Guide - Page 90
    Warranty Returning a Defective Product Before returning any product, call your authorized dealer/distribution authority. 90 Intel® Entry Server Platform SR1325TP1-E User Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

Intel
®
Entry Server Platform SR1325TP1-E
User Guide
A Guide for Technically Qualified Assemblers of Intel
®
Identified
Subassemblies/Products
Order Number:
C61602-001