Intel SR1475 Product Guide

Intel SR1475 Manual

Intel SR1475 manual content summary:

  • Intel SR1475 | Product Guide - Page 1
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Technical Product Specification Intel order number D54566-001 Revision 1.0 March 2006 Enterprise Platforms and Services Marketing
  • Intel SR1475 | Product Guide - Page 2
    Revision History Date March 2006 Revision Number 1.0 Initial Release Modifications Revision 1.0 ii
  • Intel SR1475 | Product Guide - Page 3
    a design. The Intel® Server Chassis SR1475 and Intel® Server System SR1475NH1-E may contain design defects part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means without the express written consent of Intel Corporation. Intel, Pentium
  • Intel SR1475 | Product Guide - Page 4
    18 - 1.9 Chassis Security 18 - 1.10 Rack and Cabinet Mounting Options 18 - 1.11 Front Bezels...- 18 - 2. Cooling Sub-System ...- 20 - 2.1 System Fans...- 21 - 2.2 Power Supply Fans 22 - 2.3 CPU/Memory Air Duct and Side Air Baffle 22 - 3. Peripheral and Hard Drive Support 24
  • Intel SR1475 | Product Guide - Page 5
    Control Panel Assembly Headers 47 - 5. PCI Riser Cards and Assembly 49 - 5.1 Riser Card Options 50 - 6. Power Sub-system ...- 51 - 6.1 6.5.1 P1 Main power connector 54 - 6.5.2 P2 Processor Power Connector 54 - 6.5.3 HD Power Connector (P3 55 - 6.5.4 Slim-line Power Connector (P4 55
  • Intel SR1475 | Product Guide - Page 6
    Factor Correction 60 - 6.19 Efficiency ...- 60 - 6.20 Grounding ...- 60 - 6.21 Remote Sense 60 - 6.22 Output Power / Currents 61 - 6.22.1 Standby Outputs 61 - 6.22.2 Fan Operation in Stand-By Mode 61 - 6.23 Voltage Regulation 61 - 6.23.1 Dynamic Loading 62 - 6.24 Capacitive
  • Intel SR1475 | Product Guide - Page 7
    Serviceability...- 73 - 7.7 Power Supply Returned for Repair 73 - 7.8 Modifications / Change Control 73 - 7.9 Power Supply Compliance Overview 73 - 7.10 Power Supplies Allowable Temperatures on Power Cords 76 - 8. Supported Intel® Server Boards 77 - 8.1 Intel® Server Board SE7230NH1-E
  • Intel SR1475 | Product Guide - Page 8
    82 - 9.2.5 Japan EMC Compatibility 83 - 9.2.6 BSMI (Taiwan 83 - 9.3 Replacing the Back up Battery 84 - 9.4 System Level Environmental Limits 85 - 9.5 Serviceability...- 85 - Appendix A: Intel® Server Chassis SR1475 Integration and Usage Tips 3 - Glossary...- 4 - Revision 1.0 viii
  • Intel SR1475 | Product Guide - Page 9
    30. Intel® Server Chassis SR1475 SATA HSBP I2C Bus Connection Diagram 40 Figure 31. Standard Control Panel Assembly Module 44 Figure 32. Standard Control Panel Buttons 44 Figure 34. PCI Riser Bracket and Optional PCI-X* and PCI Express* Risers 49 Figure 35. 1U Full Height PCI-X* Riser Card
  • Intel SR1475 | Product Guide - Page 10
    Figure 36. 1U Full Height PCI Express* Riser Card Mechanical Drawing 50 Figure 37. Power Supply Enclosure Drawing 51 Figure 38. Airflow Characteristics 52 Figure 39. Output Voltage Timing 64 Figure 40. Turn On/Off Timing (Power Supply Signals 66 Figure 41. PSON# Required Signal Characteristic
  • Intel SR1475 | Product Guide - Page 11
    Chassis Dimensions 14 Table 2. Major Chassis Components 15 Table 3. Individual Fan Assembly Pin-out (J5J1, J4J1, J4J3, J4J2 22 Table 4. 4-pin Floppy Power Main Power Connector 54 Table 26. P2 Processor Power Connector 54 Table 27. HD Power Connector 55 Table 28. Slim-line Power Connector
  • Intel SR1475 | Product Guide - Page 12
    Table 35. Voltage Regulation Limits 61 Table 36. Transient Load Requirements 62 Table 37. Capacitve Loading Conditions 62 Table 38. Ripple and Noise...- 63 Table 39. Output Voltage Timing 64 Table 40. Turn On/Off Timing 65 Table 41. Over Current Protection (OCP 67 Table 42. Over-Voltage
  • Intel SR1475 | Product Guide - Page 13
    Server Chassis SR1475/ Intel® Server System SR1475NH1-E 1. Intel® Server Chassis SR1475 Feature Summary The Intel® Server Chassis SR1475 is a 1U server chassis specifically designed to support the Intel® Server Board SE7230NH1-E. The Intel® Server Chassis SR1475 is available as a standalone chassis
  • Intel SR1475 | Product Guide - Page 14
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 1.2 Chassis Dimensions Height Width Depth Max. Weight Table 1. Chassis Dimensions 43.25 mm 430 mm 672 mm 14.1 kg 1.703" 16.930" 26.457" 31 LBS 1.3 Intel® Server Chassis SR1475 System Components C B A D E J I H G F Figure 4.
  • Intel SR1475 | Product Guide - Page 15
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Table 2. Major Chassis Components A Power Supply B Chassis Intrusion Switch C PCI Riser Card Assembly Placement D CPU Air Duct Placement E System Fan Module F Control Panel G Hard Drive Bays H Slim-line Drive Bay I PS / Electronics
  • Intel SR1475 | Product Guide - Page 16
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Figure 6. Front Panel Feature Overview A Slim-line drive bay (CD-ROM or DVD/CDR or Floppy) B Control Panel C Hard Drive Fault/Activity LED D 1" Hard Drive Bays E Chassis Handle 1.6 Control Panel The server chassis control panel assembly
  • Intel SR1475 | Product Guide - Page 17
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Figure 7. Control Panel Module The control panel supports several push K J Figure 8. Standard Control Panel Overview A Power / Sleep Button B NIC #2 Activity LED C NIC #1 Activity LED D Power / Sleep LED E Not Used F Hard Drive
  • Intel SR1475 | Product Guide - Page 18
    system fans and dual non-redundant power supply fans to provide sufficient air flow for fixed and hot-swap drive configurations, processors, memory, and an add-in card, when external ambient temperatures remain within specified limits. 1.9 Chassis Security The server chassis provides support for
  • Intel SR1475 | Product Guide - Page 19
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Figure 9. Optional Front Bezel Light pipes in the front bezel supporting the standard control panel allow the system status LEDs to be monitored with the bezel installed Figure 10. Front Bezel Options Revision 1.0 - 19 -
  • Intel SR1475 | Product Guide - Page 20
    Intel® Server Chassis SR1475/ Intel® Server System SR1475NH1-E 2. Cooling Sub-System The cooling sub-system on the server chassis is compromised of four 40x40x56mm dual rotor fans, one 40x40x28mm single rotor fan, two 40x40x28mm power supply fans, a CPU/memory air duct, and a PS/electronics bay
  • Intel SR1475 | Product Guide - Page 21
    SR1475 / Intel® Server System SR1475NH1-E 2.1 System Fans The server chassis system fans consist of four 40x40x56mm dual rotor and one 40x40x28mm single rotor multi-speed fans, which provide the primary airflow for the system. The four dual rotor fans provide the primary cooling for the processor
  • Intel SR1475 | Product Guide - Page 22
    replaced. The system fans are not hot-swapable. 2.2 Power Supply Fans The power supply supports two non-redundant 40mm fans. They are responsible for the cooling of the power supply and drive bay 1 (the far left hard drive as viewed from the front of the chassis). 2.3 CPU/Memory Air Duct and Side
  • Intel SR1475 | Product Guide - Page 23
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E The CPU/memory air duct must be properly installed to direct airflow through the processor heatsink and the memory area of the system. Figure 15. CPU/Memory Air Duct Notes: 1. If the CPU/memory air duct is removed, the system will not
  • Intel SR1475 | Product Guide - Page 24
    Intel® Server Chassis SR1475/ Intel® Server System SR1475NH1-E 3. Peripheral and Hard Drive Support The server chassis provides three hard drive bays and one slim-line peripheral drive bay at the front of the chassis. The drive bays are designed to support both fixed and hot-swap SCSI and SATA drive
  • Intel SR1475 | Product Guide - Page 25
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.1.1 Floppy Drive Support With or Without Backplane Present The floppy drive is mated with an interposer card which provides the power and IO interconnects between the drive, power supply, and the server board. Note: The 100-pin
  • Intel SR1475 | Product Guide - Page 26
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.1.2 Optional Floppy Drive Configuration For system configurations that require a CD-ROM or DVD-CDR and floppy drive, where using a USB floppy or USB CD-ROM is not desired, an accessory kit which consists of a slim-line floppy drive
  • Intel SR1475 | Product Guide - Page 27
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E The second connector has 4 pins and is cabled to the 2x3 pin power lead from the power supply. The power cable for the drive is included in the Intel® Server Chassis SR1475 in the form of a Y power cable. Both ends of the Y cable are
  • Intel SR1475 | Product Guide - Page 28
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.2 Hard Disk Drive Bays The server chassis can be configured to support either fixed or hot-swap SCSI or SATA hard drive configurations. For hot-swap drive configurations, 3.5" x 1" hard disk drives are mounted to hot-swap drive
  • Intel SR1475 | Product Guide - Page 29
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E E A B C D OM11684 Figure 20. Hard Drive Tray Assembly A. Hard Drive to slide into the drive bay and lock into place. To remove the drive, the chassis top cover must be removed to disengage the drive tray latch from the bay. 3.2.3
  • Intel SR1475 | Product Guide - Page 30
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.3 Hot-Swap SCSI Backplane The Intel® Server Chassis SR1475 SCSI hot-swap backplane (HSBP) supports the following feature set: ƒ QLogic* GEM359 enclosure management controller o External non-volatile Flash ROM o I2C interface o Low
  • Intel SR1475 | Product Guide - Page 31
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.3.2 SCSI Backplane Functional Architecture This section in-band SAF-TE and SES management through the SCSI interface. Also supported is the I2C connection to the server board. The GEM359 comes in a 144-pin low profile Quad Flat
  • Intel SR1475 | Product Guide - Page 32
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.3.2.2 SCSI Interface The GEM359 supports LVD SCSI operation through 8-bit asynchronous SCSI data transfers. The following SCSI command set is supported: ƒ Inquiry ƒ Read Buffer ƒ Write Buffer ƒ Test Unit Ready ƒ Request Sense ƒ
  • Intel SR1475 | Product Guide - Page 33
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Figure 24. Intel® Server Chassis SR1475 SCSI HSBP I2C Bus Connection Diagram 3.3.2.4 External Memory Device The SCSI backplane contains a non-volatile 16K top boot block, 4Mbit Flash memory device that stores the configuration data
  • Intel SR1475 | Product Guide - Page 34
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.3.3 SCSI Backplane Connector Definitions As a multi-functional board, several connectors can be found on the SCSI backplane. This section defines the purpose and pin-out associated with each connector. 3.3.3.1 Power Connector (
  • Intel SR1475 | Product Guide - Page 35
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Table 10. UltraWide (SE) and Ultra2 (LVD) Ultra320 SCSI Connector Pin-out (J8) Name BP_SCSI_D12P BP_SCSI_D13P BP_SCSI_D14P BP_SCSI_D15P BP_SCSI_DP1P BP_SCSI_D0P BP_SCSI_D1P BP_SCSI_D2P BP_SCSI_D3P BP_SCSI_D4P BP_SCSI_D5P
  • Intel SR1475 | Product Guide - Page 36
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.3.3.3 SCA2 Hot-Swap SCSI Drive Connectors The SCSI backplane provides three hot-swap SCA2 connectors, which provide power and SCSI signals using a single connector. Each SCA drive attaches to the backplane using one of these
  • Intel SR1475 | Product Guide - Page 37
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1 3.4 Hot-Swap SATA Backplane The Intel® Server Chassis SR1475 SATA hot-swap backplane (HSBP) supports the following feature set: ƒ (IPMI) ƒ Support for up to three SATA drives ƒ Hot-Swap drive support ƒ One 2 x 3-pin power connector ƒ IDE
  • Intel SR1475 | Product Guide - Page 38
    connectors of the board. Floppy drive connector (not used in Intel® Server Chassis SR1475) Power connector IDE connector (not used in Intel® Server Chassis SR1475) 100-pin connector (not used in Intel® Server Chassis SR1475) SATA connectors SATA drive connectors Figure 27. SATA Backplane Layout
  • Intel SR1475 | Product Guide - Page 39
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.4.2 SATA Backplane Functional Architecture This section provides a high-level description of the functionality distributed between the architectural blocks of the SATA backplane. The following figure
  • Intel SR1475 | Product Guide - Page 40
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.4.2.2 SATA Interface The GEM424 implements SAF-TE over the HBA I2C interface. The GEM424 supports the following SAF-TE command set: ƒ Read Enclosure Configuration ƒ Read Enclosure Status ƒ Read Device Slot Status ƒ Read Global
  • Intel SR1475 | Product Guide - Page 41
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.4.2.3 External Memory or, for drives that support the feature, by the Power Connector The SATA backplane provides power for up to three SATA drives, and one floppy drive or CDROM drive. A 6-pin power cable from the power supply
  • Intel SR1475 | Product Guide - Page 42
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.4.3.2 SATA Connectors (Backplane to Server Board) The SATA backplane has three 7-pin SATA connectors (Drive0, Drive1 and Drive2). These connectors correspond to the SATA connectors on the Intel® Server SATA and power signals into
  • Intel SR1475 | Product Guide - Page 43
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 3.4.3.5 Slim-line CD-ROM / DVD Interface Assembly When a CD-ROM or DVD drive is installed into the slim-line peripheral bay, the drive cable is routed from a connector on the drive interposer card, to the server board legacy IDE
  • Intel SR1475 | Product Guide - Page 44
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 4. Standard Control Panel The standard control panel supports several push buttons and status LEDs, along with USB and video ports to centralize system control, monitoring, and accessibility to within a common compact design. The
  • Intel SR1475 | Product Guide - Page 45
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Table 16. Standard Control Panel Button Functions Reference A B C D Feature Power / Sleep Button ID Button Reset Button NMI Button Function Toggles the system power on/off. This button also functions as a Sleep Button if enabled by
  • Intel SR1475 | Product Guide - Page 46
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E The following table identifies each LED and describes their functionality. Table 17. Standard Control Panel LED Functions LED Color State Description NIC1 / NIC2 Green On NIC Link Activity Green Blink NIC Activity Power /
  • Intel SR1475 | Product Guide - Page 47
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 4.2.3 System Identification LED The blue system identification LED is used to help identify a system for servicing. This is especially useful when the system is installed in a high density rack or cabinet that is populated with
  • Intel SR1475 | Product Guide - Page 48
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E The following tables provide the pin-outs for both types of connectors. Table 20. 50-pin Control Panel Connector (J3) Description PWR_LCD_5VSB HDD_LED_ACT_R_L RST_P6_PWRGOOD P5V_STBY
  • Intel SR1475 | Product Guide - Page 49
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 5. PCI Riser Cards and Assembly The Intel® Server Board SE7230NH1-E provides one PCI riser slot (Intel® Adaptive Slot), supporting full height/full length add-in card risers. The riser slot is capable of supporting risers that follow
  • Intel SR1475 | Product Guide - Page 50
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 5.1 Riser Card Options There are two different riser card options offered for use in the Intel® Server Chassis SR1475. • PCI-X* - capable of supporting a single full height/full length PCI-X* 66/100 MHz add-in card. • PCI Express* -
  • Intel SR1475 | Product Guide - Page 51
    to the power supply. The power supply provides two nonredundant 40mm fans for self cooling. The power supply fans also provide additional airflow for parts of the system. 6.1 Mechanical Specifications The 1U 350 W power supply is designed specifically for use in the Intel® Server Chassis SR1475. The
  • Intel SR1475 | Product Guide - Page 52
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.2 Airflow Requirements The power supply shall incorporate two 40mm fans for self-cooling and system cooling. The fans will provide no less than 8 CFM airflow through the power supply when installed in the system. The cooling air will
  • Intel SR1475 | Product Guide - Page 53
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Table 22. Acoustic Requirements Operating Conditions Maximum Operating Idle Standby (main outputs off) Inlet Temperature Condition 45ºC 28°C 28°C 28°C % of Maximum Loading Condition 100%
  • Intel SR1475 | Product Guide - Page 54
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.5.1 P1 Main power connector Connector housing: 20-Pin Molex* Mini-Fit Jr. 39-01-2200 or equivalent. Contact: Molex Mini-Fit, HCS, female, crimp 44476 or Molex 5556 as the alternative, or equivalent approved by Intel Processor Power
  • Intel SR1475 | Product Guide - Page 55
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.5.3 HD Power Connector (P3) Connector housing: 6-pin Molex* 39-01-2065 or equivalent. Contacts: Molex Mini-Fit, (HCS or standard), female, crimp or equivalent. Table 27. HD Power Connector Pin Signal 1 COM 2 COM 3 +5VDC
  • Intel SR1475 | Product Guide - Page 56
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.8 AC Input Voltage The power supply must operate within all specified limits over the following input voltage range, shown in table below. Harmonic distortion of up to 10% of the rated line voltage must not cause the power supply to
  • Intel SR1475 | Product Guide - Page 57
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Duration Continuous 0 to ½ AC cycle Table : 1992. The pass criteria includes: no unsafe operation exists under any condition; all power supply output voltage levels remain within proper spec levels; no change in operating state or loss
  • Intel SR1475 | Product Guide - Page 58
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-45:1995 test standard and performance criteria B defined in Annex B of CISPR 24. 6.11 AC Line Fast Transient (EFT) Specification The power supply
  • Intel SR1475 | Product Guide - Page 59
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.13.1 Voltage Brown Out The power supply shall comply with the limits defined in EN55024: 1998 using the IEC 61000-411:1995 test standard and performance criteria C defined in Annex B of CISPR 24. In addition the power supply shall
  • Intel SR1475 | Product Guide - Page 60
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.17 AC Line Fuse The power supply Power Factor Correction The power supply shall incorporate a Power Factor Correction circuit. The power supply shall be tested as described in EN 61000-3-2: Electromagnetic Compatibility (EMC) Part
  • Intel SR1475 | Product Guide - Page 61
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.22 Output Power / Currents The following tables define two power and current ratings for this 350 W power supply. The combined output power of all outputs shall not exceed the rated output power. The power supply must meet both
  • Intel SR1475 | Product Guide - Page 62
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.23.1 Dynamic Loading The output voltages happen simultaneously and it shall be tested that way. 6.24 Capacitive Loading The power supply shall be stable and meet all requirements with the following capacitive loading ranges. Table
  • Intel SR1475 | Product Guide - Page 63
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.26 Common Mode Noise The common source current without fault. 6.30 Timing Requirements These are the timing requirements for the power supply operation. The output voltages must rise from 10% to within regulation limits (Tvout_rise)
  • Intel SR1475 | Product Guide - Page 64
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E turn off. The table below shows the timing requirements for the power supply being turned on and off via the AC input, with PSON held low and with the AC input applied. Table 39. Output Voltage Timing Item
  • Intel SR1475 | Product Guide - Page 65
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Table 40. Turn On/Off Timing Item Description MIN Tsb_on_delay Delay from AC being applied to 5VSB being within regulation. T ac_on_delay Delay from AC being
  • Intel SR1475 | Product Guide - Page 66
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E AC Input Vout TAC_on_delay . 6.32 Protection Circuits Protection circuits inside the power supply shall cause only the power supply's main outputs to shutdown. If the power supply latches off due to a protection circuit tripping,
  • Intel SR1475 | Product Guide - Page 67
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.33 Over-Current Limit (OCP) The power supply shall have current limits to prevent the +3.3V, +5V, and +12V outputs from exceeding the values shown in the table below. If the current limits are exceeded, the power supply shall
  • Intel SR1475 | Product Guide - Page 68
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.35 Over-Temperature Protection (OTP) The power supply will be protected against over-temperature conditions caused by loss of fan cooling or excessive ambient temperature. In an OTP condition the power supply will shutdown. When the
  • Intel SR1475 | Product Guide - Page 69
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Disabled 0.3V ≤ Hysteresis ≤ 1.0V in 1.0-2.0V input voltage range is required ≤ 1.0 V PS is enabled ≥ 2.0 V PS is disabled Enabled 0V 1.0V 2.0V 5.25V Figure 41. PSON# Required Signal Characteristic. 6.38 PWOK (Power power supply
  • Intel SR1475 | Product Guide - Page 70
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 6.39 Environmental Requirements 6.39.1 Temperature Operating Ambient, normal mode ( LXY, and LXZ. 6.39.8 Catastrophic Failure The power supply shall be designed to fail without startling noise or excessive smoke. Revision 1.0 -
  • Intel SR1475 | Product Guide - Page 71
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 7. Electromagnetic Compatibility 7.1 EMI The power supply shall comply with FCC Part 15, CISPR 22 and EN55022; Class A for both conducted and radiated emissions with a 10dB margin. Tests shall be conducted using a shielded DC output
  • Intel SR1475 | Product Guide - Page 72
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 7.3 Magnetic Leakage Fields The PFC choke magnetic leakage field shall not cause any interference with a high resolution computer monitor placed next to or on top of the end use chassis. Final acceptable leakage field strength will be
  • Intel SR1475 | Product Guide - Page 73
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 7.6.2 Serviceability No troubleshooting by maintenance personnel is to be performed. Only unit replacement will be done in the field. 7.7 Power Supply Returned for Repair Power supplies returned to the vendor for repair, are
  • Intel SR1475 | Product Guide - Page 74
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 7.10 Power Supplies Compliance Information Australia / New Zealand Canada / USA China (CNCA) Europe (CE) / Germany International Nordics AS/NZS 3562 (CB deviation) UL60 950 - CSA60 950 GB4943 EN60
  • Intel SR1475 | Product Guide - Page 75
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 7.12 Immunity Compliance Information Europe (CE) - 89/336/EEC China (CNCA) International EN55024 N/A - Not Required CISPR 24 Notes: For immunity, the power supply shall comply with the following particular standards. 1. EN 61000-4-2
  • Intel SR1475 | Product Guide - Page 76
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Examples of Blue Angel, TCO, and Green PC eco-labels require that plastic parts > 25g chance to touch the hot surface of the power supply. 7.15.6 Date Coded Serial Numbers The power supply shall be marked with a date-coded number for
  • Intel SR1475 | Product Guide - Page 77
    SR1475NH1-E 8. Supported Intel® Server Boards The Intel® Server Chassis SR1475 is mechanically and functionally designed to support the Intel® Server Board SE7230NH1-E. 8.1 • • • Intel® Server Board SE7230NH1-E Feature Set Processor and Front Side Bus (FSB) support ƒ Supports Intel® Pentium
  • Intel SR1475 | Product Guide - Page 78
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E • Fan Support ƒ Two general purpose 3-pin fans ƒ Two general purpose 4-pin fans ƒ One 4-pin processor fan (active heatsink required) ƒ Four 8-pin dual rotor fans for Intel high density applications (Intel® Server Chassis SR1475 and
  • Intel SR1475 | Product Guide - Page 79
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Table 46: Baseboard Layout Reference Ref Description A Chassis Intrusion Header B PCI (32bit/33MHz) Slot 1 C PCI (32bit/33MHz) Slot 2 D ATI ES1000 Video Controller E PCI Express* x4 (x1 Lane) Slot 3 F PCI Express* x8 (x4 Lane)
  • Intel SR1475 | Product Guide - Page 80
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 9. Regulatory, Environmentals, and Specifications 9.1 Product Regulatory Compliance 9.1.1 Product Safety Compliance The Intel® Server Chassis SR1475 European Union) • EN61000-3-2 & -3 (Power Harmonics & Fluctuation and Flicker) • CE
  • Intel SR1475 | Product Guide - Page 81
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 9.1.3 Product Regulatory Compliance Markings This product is provided with the following Product Certification Markings. • UL / cUL Listing Mark • CE Mark • German GS Mark • FCC, Class A
  • Intel SR1475 | Product Guide - Page 82
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1 FCC Verification Statement Product Type: SR1475; SE7230NH1-E This device complies with Part 15 of the FCC Rules. to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497
  • Intel SR1475 | Product Guide - Page 83
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 9.2.5 Japan EMC Compatibility Electromagnetic Compatibility Notices cause radio interference. Install and use the equipment according to the instruction manual. 9.2.6 BSMI (Taiwan) The BSMI Certification number and the following
  • Intel SR1475 | Product Guide - Page 84
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E 9.3 Replacing the Back up Battery The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored
  • Intel SR1475 | Product Guide - Page 85
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E serviced by qualified technical personnel only. Power must be removed from the system prior to opening the chassis for service. The desired Mean Time To Repair (MTTR) of the system is 30 minutes including diagnosis of the system problem
  • Intel SR1475 | Product Guide - Page 86
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Table 48. Mean Time To Repair Estimate Activity Remove cover Remove and replace hard disk drive Remove and replace power supply module Remove and replace system fan Remove and replace backplane board Remove and replace front panel
  • Intel SR1475 | Product Guide - Page 87
  • Intel SR1475 | Product Guide - Page 88
    system prior to opening the chassis for service. • Only low-profile (1.2 in or 30.48 mm) DIMMs can be used in the server chassis. • Processor fans are not supported and are not needed in the server chassis. The fan pack, power supply fans and passive processor heatsink provide the necessary cooling
  • Intel SR1475 | Product Guide - Page 89
    Intel® Server Chassis SR1475 / Intel® Server System SR1475NH1-E Glossary Word / Acronym ACA ANSI BMC CMOS D2D EMP FP Over Temperature Protection Over Voltage Protection Power Factor Correction Platform Management Controller Power Supply Unit Processor Wind Tunnel Ring Indicate Single
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89

Intel
®
Server Chassis SR1475 / Intel
®
Server System SR1475NH1-E
Technical Product Specification
Intel order number D54566-001
Revision 1.0
March 2006