Intel SRCSASJV Hardware User Guide

Intel SRCSASJV - RAID Controller Manual

Intel SRCSASJV manual content summary:

  • Intel SRCSASJV | Hardware User Guide - Page 1
    Intel® RAID Controller SRCSASJV Hardware User's Guide Intel Order Number: E16747-001
  • Intel SRCSASJV | Hardware User Guide - Page 2
    its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2007 by Intel Corporation. Portions Copyright 2005-2007 by LSI Logic Corporation. All rights reserved. ii Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 3
    hardware guide for the Intel® RAID Controller SRCSASJV, which can be used for SAS and SATA disk drives. It contains installation instructions and specifications. For details on how to configure the storage adapters, and for an overview of the software drivers, see the Software User's Guide on
  • Intel SRCSASJV | Hardware User Guide - Page 4
    iv Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 5
    System Support 2 Usability ...2 Redundancy and Error Handling 3 SAS/SATA Features of the 1078 Controller 4 Beep Codes ...5 Chapter 2, Intel® RAID Controller SRCSASJV Hardware Installation 6 Requirements ...6 Install the RAID Controller ...6 Configure the RAID Controller 9 Replacing a Controller
  • Intel SRCSASJV | Hardware User Guide - Page 6
    that use cost-effective SATA or high performance SAS media. As a third generation PCI Express storage controller, the Intel® RAID Controller SRCSASJV addresses the architecture, while maintaining compatibility with existing ATA firmware. 1 Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 7
    list for your server board at http://support.intel.com/support/motherboards/server/. See also the tested hardware and operating system list for the RAID Controller SRCSASJV to make sure the RAID card supports your operating system. Usability • The card ships with both a standard and a low-profile
  • Intel SRCSASJV | Hardware User Guide - Page 8
    to recognize an error and recover if possible. • Failures are logged from controller and drive firmware, and SMART monitor. • Failures are logged in NVRAM, viewable from OS Event Log, Intel® RAID Web Console 2; CIM, LEDs, and via alarm. 3 Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 9
    configuration-specific performance support. - Optional battery backup for cache memory. Controller provides fast or trickle charges. SAS/SATA Features of the 1078 Controller • Provides eight independent phys, each supporting configuration). Intel® RAID Controller SRCSASJV Hardware User's Guide 4
  • Intel SRCSASJV | Hardware User Guide - Page 10
    , choose Disable Alarm. To enable alarm, choose Enable Alarm To disable alarm only until the next event or until next power cycle, choose Silence Alarm. 5 Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 11
    4. Install the RAID controller into an available server system x8 or x16 PCI-Express* slot. See your server system documentation to locate an appropriate slot and for instructions on installing an add-in card. See also the following figure. Intel® RAID Controller SRCSASJV Hardware User's Guide 6
  • Intel SRCSASJV | Hardware User Guide - Page 12
    , see the following figure. To prevent throughput problems, use the cables provided or use the shortest SAS or SATA backplane, or an expander device. Route the cables carefully. Check that controller and cables are all properly attached. 7 Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 13
    AF002211 Figure 3. Connecting Cables between the RAID Controller and Drives/Backplane 6. Install the server system cover and connect the power cords. See your server system documentation for instructions. Intel® RAID Controller SRCSASJV Hardware User's Guide 8
  • Intel SRCSASJV | Hardware User Guide - Page 14
    RAID Controller SRCSASJV number and firmware version. The numbering of the RAID controller follows the PCI slot scanning order used by the server board. 3. See the Intel® RAID Controller SRCSASJV Quick Start User's Guide and the Software User's Guide for instructions to configure the RAID controller
  • Intel SRCSASJV | Hardware User Guide - Page 15
    hot-swap backplane Default is for no jumper Provides signal to enclosure to indicate that the cache needs to write data Cable connector to the battery backup pack. This connector is on the back of the card Figure 4. Card Layout Intel® RAID Controller SRCSASJV Hardware User's Guide 10
  • Intel SRCSASJV | Hardware User Guide - Page 16
    Processor Operating voltage Card size Array interface to host SATA bus speed Serial port SAS controller SAS/SATA ports Physical and virtual drive support Cache Firmware Compatible devices Cabling Redundant configuration Enclosure management Enclosure support Array support Intel® RAID Controller
  • Intel SRCSASJV | Hardware User Guide - Page 17
    the internal performance of all motors, heads, and drive electronics. Intel® RAID Smart Battery cache backup. Up to 72 hours of data retention. If use 72b configuration (3) 64Mx16 in NVRAM, event log, CIM, Smart, Intel® RAID Web Console 2 Intel® RAID Controller SRCSASJV Hardware User's Guide 12
  • Intel SRCSASJV | Hardware User Guide - Page 18
    LFPM relative humidity non-condensing: 5%-90%. With battery 20-80% 10-90% condensing Safety Characteristics The Intel® RAID Controller SRCSASJV meets or exceeds the requirements of UL flammability are lower than the SELV 42.4 V limit. 13 Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 19
    Intel® RAID Controller SRCSASJV Hardware User's Guide 14
  • Intel SRCSASJV | Hardware User Guide - Page 20
    inserted properly. 6. Follow the instructions that came with your server system to remove the server cover. 7. Plug in and power on the system. The controller detects the RAID configuration from the configuration data on the drives (COD). 15 Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 21
    9. Follow the instructions that came with your server system to remove the server cover. 10. Plug in and power on the system. When you start the system, the controller detects the RAID configuration from the configuration data on the drives. Intel® RAID Controller SRCSASJV Hardware User's Guide 16
  • Intel SRCSASJV | Hardware User Guide - Page 22
    on a rug. When working inside your computer: • Do not attempt to service the computer system yourself, except as explained in this guide and elsewhere in Intel documentation. Always follow installation and service instructions closely. • Turn off your computer and any peripherals. • Disconnect your
  • Intel SRCSASJV | Hardware User Guide - Page 23
    You can do so by touching an unpainted metal surface, such as the metal around the card-slot openings at the back of the computer. • As you continue to work inside the area. If possible, use antistatic floor pads and workbench pads. Intel® RAID Controller SRCSASJV Hardware User's Guide 18
  • Intel SRCSASJV | Hardware User Guide - Page 24
    performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http:\\support.intel.com\support\motherboards Check that cables, add-in cards, and other components are properly Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 25
    auch die Sicherheitshinweise zu Intel-Serverplatinen und -ServergehŠusen auf der Ressourcen-CD oder unter http:\\support.intel.com\support\motherboards\server\sb\cs-010770.htm das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. Intel® RAID Controller SRCSASJV Hardware User's Guide 20
  • Intel SRCSASJV | Hardware User Guide - Page 26
    Platinen und Gehäuseteile scharfe Spitzen und Kanten aufweisen. Arbeiten an Platinen und Gehäuse sollten vorsichtig ausgeführt werden. Sie sollten Schutzhandschuhe tragen. 21 Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 27
    ème. Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. CONSIGNES DE SÉCURITÉ -Lorsque vous ouvrez le boîtier pour accéder à l'inté cordons d'alimentation c. a. et câbles externes au système. Intel® RAID Controller SRCSASJV Hardware User's Guide 22
  • Intel SRCSASJV | Hardware User Guide - Page 28
    toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site http:\\support.intel.com\support\motherboards\server\ si se han extraído las tapas del chasis. 23 Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 29
    nel pannello anteriore non interrompe l'alimentazione in c.a. del sistema. Per interromperla, è necessario scollegare tutti i cavi di alimentazione in c.a. dalle prese a muro o dall'alimentazione di corrente. Intel® RAID Controller SRCSASJV Hardware User's Guide 24
  • Intel SRCSASJV | Hardware User Guide - Page 30
    di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. 25 Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 31
    (EMC) & 1997-42 (EMI) (Korea) Product Regulatory Compliance Markings The RAID Controller Card is marked with the following compliance markings. Some marking information may be provided CE Mark (Europe) • VCCI Mark (Japan) • MIC Mark (Korea) Intel® RAID Controller SRCSASJV Hardware User's Guide 26
  • Intel SRCSASJV | Hardware User Guide - Page 32
    VCCI Marking (Class A) Japan CANADA ICES-003 CLASS A CANADA NMB-003 CLASSE A CANADA ICES-003 CLASS B CANADA NMB-003 CLASSE B VCCI Marking (Class B) Japan 27 Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 33
    . Intel Corporation 5200 instructions, user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. Intel® RAID Controller SRCSASJV Hardware User's Guide
  • Intel SRCSASJV | Hardware User Guide - Page 34
    local Intel representative - Name of Certification Recipient: LSI Logic Corporation - Date of Manufacturer: Refer to date code on product - Manuation: LSI Logic Corporation Manufacturer/Nation / Refer to country of origin marked on product 29 Intel® RAID Controller SRCSASJV Hardware User's Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

Intel
®
RAID Controller SRCSASJV
Hardware User’s Guide
Intel Order Number: E16747-001