    Invacare® Reliant™ 450 RPL450-2 Invacare® Reliant 600 RPL600-2 Electric Portable Patient Lift User Manual EN This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.
  • Invacare RPL450-2 | Owners Manual - Page 2
    or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by ™ and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. Electric Portable Patient Lift 2 Part No. 1145810
  • Invacare RPL450-2 | Owners Manual - Page 3
    Patient Lift 13 Full Body, Divided Leg and Toileting Slings 14 Reliant Scale RLS6 14 5 ASSEMBLY 15 Introduction 15 Unpacking the Patient Lift 15 23 7 LIFTING THE PATIENT 24 Introduction 24 Positioning the Patient Lift 24 Attaching a Sling 25 Lifting/Moving the Patient 26 Part No.
  • Invacare RPL450-2 | Owners Manual - Page 4
    42 Reliant Scale RLS6 42 Removing the Swivel Bar 42 Installing the Reliant Scale 44 Operating the Scale 46 Keypad Functions 46 Weighing the Patient 47 Replacing the Battery 48 Calibrating the Reliant Scale 49 Troubleshooting 50 Display Codes 50 Electric Portable Patient Lift 4 Part No
  • Invacare RPL450-2 | Owners Manual - Page 5
    1 GENERAL 1.1 Symbols Warnings Signal words are used in this manual and apply to hazards or unsafe practices which could result in is not avoided.  Gives useful tips, recommendations and information for efficient, trouble-free use. Part No. 1145810 5 Electric Portable Patient Lift
  • Invacare RPL450-2 | Owners Manual - Page 6
    , OR TO A PRODUCT DAMAGED BY CIRCUMSTANCES BEYOND INVACARE'S CONTROL, AND SUCH EVALUATION WILL BE SOLELY DETERMINED BY INVACARE. THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE INSTRUCTIONS IN THIS MANUAL. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU
  • Invacare RPL450-2 | Owners Manual - Page 7
    . Contact the Dealer for further instructions. 2.2 Operating Information General ƽ WARNING The Invacare patient lift is NOT a transport device. It is intended to transfer an individual from one resting surface to another (such as a bed to a wheelchair). Otherwise injury or damage may occur
  • Invacare RPL450-2 | Owners Manual - Page 8
    . Operating the Lift ƽ WARNING Although Invacare recommends that two assistants be used for all lifting preparation, transferring lift. The weight limitation for the RPL450-2 is 450 lbs. The weight limitation for the RPL600-2 is 600 lbs. ALWAYS keep hands and fingers clear of moving parts
  • Invacare RPL450-2 | Owners Manual - Page 9
    onto the stationary object (wheelchair, commode, or bed) and correct this problem. Adjustments for safety and comfort should be made before moving the patient. Patient's arms should be inside of the straps. Invacare slings are made specifically for use with Invacare Patient Lifts. For the safety of
  • Invacare RPL450-2 | Owners Manual - Page 10
    patient back onto the stationary object (wheelchair, commode, or bed) and correct this problem. Wheelchair wheel locks MUST be in a locked metal is worn, the parts MUST be replaced. Make this inspection every six months thereafter. Regular maintenance of patient lifts and accessories is necessary
  • Invacare RPL450-2 | Owners Manual - Page 11
    INSTRUCTIONS DO NOT, under any circumstances, cut or remove the round grounding prong from any plug used with or for Invacare charger information prior to installing, servicing or operating your patient lift. Disposal WARNING This product has been . Part No. 1145810 11 Electric Portable Patient
  • Invacare RPL450-2 | Owners Manual - Page 12
    during lifting procedures. USE ONLY Invacare slings and lift accessories. For maintenance and replacement, use only components designed for this patient lift model. See the product label for model information. Customer Service 1-800-333-6900 1070965 Rev B Electric Portable Patient Lift 12 Part No
  • Invacare RPL450-2 | Owners Manual - Page 13
    Time: Accessories: Audio Low Battery Alarm: Motor Safety Devices: Approx. Lifts per Charge (Varies depending upon load and stroke): Warranty Electronics: Part No. 1145810 4 TECHNICAL DATA 450 LB. ELECTRIC LOW PROFILE RPL450-2 74 inches 24 inches 3 Styles 450 lbs 136 lbs 109 lbs 41.0 inches 26
  • Invacare RPL450-2 | Owners Manual - Page 14
    N/A N/A 7 37 55 55 N/A N/A 13 N/A N/A N/A 450 600 600 4.3 Reliant Scale RLS6 Weight Range: Resolution: Display: Automatic Power Down: Size: Weight: Power: Battery (included) Approximately 1500 readings 50° To 104°F (10° To 40°C) Electric Portable Patient Lift 14 Part No. 1145810
  • Invacare RPL450-2 | Owners Manual - Page 15
    5 Assembly 5 ASSEMBLY 5.1 Introduction ƽ WARNING Use only Invacare parts in the assembly of this patient lift. The base legs, mast, boom assembly and the swivel bar are manufactured to specifications that assure correct alignment of all parts for safe functional operation. 5.2 Unpacking the
  • Invacare RPL450-2 | Owners Manual - Page 16
    mast MUST be properly secured to the base assembly. 1. If locking-type casters are on the patient lift, lock them. 2. Remove the shoulder bolt, nut and washer, that secures the mast in the Base U-shaped Cutout Shoulder Bolt Electric Portable Patient Lift 16 Mast Nut Washers Part No. 1145810
  • Invacare RPL450-2 | Owners Manual - Page 17
    to the mast mounting bracket. 3. Cut the plastic-wrap that secures the boom and mast together. 4. Lift-up on the boom and place it on your left shoulder. 5. Let the boom actuator rest on  Pinch Guard Turn 90° Boom Actuator Mast Mounting Bracket Part No. 1145810 17 Electric Portable Patient
  • Invacare RPL450-2 | Owners Manual - Page 18
    lift (Detail B). 2. Perform the following to secure the leg actuator to the pivot bracket (Detail A): ƽ WARNING Ensure that there is sufficient room to turn patient lift patient lift may occur. A. Turn the patient lift on Return the patient lift to the upright VIEW OF PATIENT LIFT Pivot Base Leg
  • Invacare RPL450-2 | Owners Manual - Page 19
    into the wall electrical outlet. 9. Verify that ON is illuminated. Mounting Bracket Battery Charger with Mounting Bracket (STEP 5) Mounting Screws 5 ASSEMBLY BOTTOM Mounting Screw (STEP 4) Part No. 1145810 19 Electric Portable Patient
  • Invacare RPL450-2 | Owners Manual - Page 20
    of the patient's physician, nurse or medical assistant. Thoroughly read the instructions in this Owner's Manual, observe a trained team of experts performing the lifting procedures and then perform the entire lift procedure several times with proper supervision and a capable individual acting as
  • Invacare RPL450-2 | Owners Manual - Page 21
    " on the control box of the lift and push down on the boom at the same time. All lift actuators are equipped with a mechanical Emergency EMERGENCY grip and push down on the boom at the same time. Part No. 1145810 21 6 OPERATION Control Box EMERGENCY EMERGENCY Emergency Release Hole Push
  • Invacare RPL450-2 | Owners Manual - Page 22
    emergency stop button clockwise to disengage the emergency stop. Control Box Rotate CLOCKWISE to Disengage Emergency Stop Press IN to Stop Boom Electric Portable Patient Lift 22 Part No. 1145810
  • Invacare RPL450-2 | Owners Manual - Page 23
    Invacare recommends the battery be recharged daily to prolong battery life. An audible alarm will sound (horn will beep) when battery is low. 1. Lift up on the handle on the back of the battery. 2. Lift to the Control Box and Battery Charger as shown. Part No. 1145810 23 Electric Portable Patient
  • Invacare RPL450-2 | Owners Manual - Page 24
    Lifting the Patient 7.1 Introduction  Invacare recommends that two assistants be used for all lifting the Patient Lift  Refer to Safety on page 7 in this manual before proceeding open the legs of the patient lift to maximum. 2. Position the patient lift using the steering handle. 3. Press
  • Invacare RPL450-2 | Owners Manual - Page 25
    Slings have six sling straps. Invacare Lift Swivel Bars have three hookup Lifting/Moving the Patient on page 26. DETAIL "A" - FULL BODY OR HEAVY DUTY SLING WITH OR WITHOUT COMMODE OPENING (FOUR STRAPS ONLY) DETAIL "B" - DIVIDED LEG SLING WITH COMMODE OPENING (SIX STRAPS) Color Coded Straps Part
  • Invacare RPL450-2 | Owners Manual - Page 26
    problem otherwise, Invacare patient lifts. Injury or damage may occur.  For this procedure, refer to FIGURE 7.1 on page 27. When the patient is lifted from the bed (with the patient's head supported will be fully supported by the patient lift.  The patient lift when moving the patient lift away
  • Invacare RPL450-2 | Owners Manual - Page 27
    DETAIL "A" - LIFTING THE PATIENT 7 LIFTING THE PATIENT DETAIL "B" - MOVING THE PATIENT Part No. 1145810 DETAIL "C" - MOVING THE PATIENT LIFT AWAY FROM THE BED FIGURE 7.1 Lifting/Moving the Patient 27 Electric Portable Patient Lift
  • Invacare RPL450-2 | Owners Manual - Page 28
    , lower the patient back onto the stationary surface and correct this problem - otherwise, injury or damage may occur. Adjustments for safety and use slings and patient lifts of different manufacturers. Invacare slings are made specifically for use with Invacare patient lifts. Otherwise, injury or
  • Invacare RPL450-2 | Owners Manual - Page 29
    . 8. To return the patient to bed, reverse the steps in Lifting the Patient on page 24. 9. To return or place the patient in a wheelchair, refer to Transferring to a Wheelchair on page 31 8 TRANSFERRING THE PATIENT Part No. 1145810 FIGURE 8.1 Transferring to a Commode Chair 29 Electric Portable
  • Invacare RPL450-2 | Owners Manual - Page 30
    apparatuses; this is an example of one. Refer to your particular portable bath instructions and use them in conjunction with this Owner's Manual. 1. Lift the patient from the bed. Refer to Lifting the Patient on page 24. 2. Press the boom up/down buttons to elevate the patient high enough to
  • Invacare RPL450-2 | Owners Manual - Page 31
    the wheelchair for transport. Otherwise, injury may result. 5. Use the straps or handles on the side and the back of the sling to guide the divided leg sling. 10. Reverse Lifting the Patient on page 26 to return to the seating surface of the wheelchair. Part No. 1145810 31 8 TRANSFERRING THE
  • Invacare RPL450-2 | Owners Manual - Page 32
    9 TROUBLESHOOTING 9 Troubleshooting SYMPTOMS FAULTS SOLUTION Patient lift feels loose. Mast/Base joint loose. Tie - may not be properly installed.  If problems are not remedied by the suggested means, please contact your dealer or Invacare. Electric Portable Patient Lift 32 Part No. 1145810
  • Invacare RPL450-2 | Owners Manual - Page 33
    each new user. Regular cleaning will reveal loose or worn parts, enhance smooth operation and extend the life expectancy of the lift. Follow the maintenance procedures described in this manual to keep your patient lift in continuous service. ITEM THE CASTER BASE Inspect for missing hardware. Base
  • Invacare RPL450-2 | Owners Manual - Page 34
    ITEM THE BOOM Check all hardware and swivel bar supports. Inspect for bends or deflections. Inspect bolted joints for wear. INITIALLY X X X X X X X X X X X X X X X X Electric Portable Patient Lift 34 INSTITUTIONAL INSPECT/ADJUST MONTHLY X X X X X X X X X X X X X IN-HOME INSPECT EVERY SIX
  • Invacare RPL450-2 | Owners Manual - Page 35
    the wheel and swivel bearings. If any parts are worn, replace these parts immediately. If you question the safety of any part of the lift, contact your Dealer immediately and advise them of the problem. 10.2 Lubricating the Lift The Invacare lift is designed for minimum maintenance. However, a six
  • Invacare RPL450-2 | Owners Manual - Page 36
    pivot for slings for signs of cracking, fraying, deformation or deterioration. Replace any defective parts immediately and ensure that the lift is not used until repairs are made. 10.4 Cleaning the Sling and the Lift The sling should be regularly washed in water, temperature not to exceed 180°F (82
  • Invacare RPL450-2 | Owners Manual - Page 37
    10.6 Checking and Tightening Mast Pivot Bolt 1. Lift up the back of the rubber boot and slide it off the mast along the locknut. 4. Reposition the rubber boot. Washer Bolt 10 MAINTENANCE Rubber Boot Boom Spacer (if equipped) Mast Locknut Bracket Part No. 1145810 37 Electric Portable Patient
  • Invacare RPL450-2 | Owners Manual - Page 38
    be inspected every six months to determine the extent of wear. If these parts become worn, replacement must be made. 1. The swivel bar comes attached to has three hooks on both ends to attach the sling that supports the patient during lift. 2. Remove existing hardware and replace the swivel bar.
  • Invacare RPL450-2 | Owners Manual - Page 39
    legs and base to determine the 90° alignment. 3. Adjust the linkage rods until 90° alignment is achieved. Square 10 MAINTENANCE Linkage Rods 90° Linkage Rod Part No. 1145810 39 Electric Portable Patient
  • Invacare RPL450-2 | Owners Manual - Page 40
    floor area is clear of debris. Otherwise, injury to personnel or damage to patient lift may occur. Replacing Rear Casters 1. Place the lift on its side. 2. Remove the bolt and locknut that secure the existing rear Caster Bushing Base Fork Bolt Electric Portable Patient Lift 40 Part No. 1145810
  • Invacare RPL450-2 | Owners Manual - Page 41
    page 40. 3. Unscrew the existing fork from the base. 4. Install the new fork onto the base. 5. Install the front or rear caster onto the lift. Refer to Replacing Casters/Forks on page 40. Locknut Front Casters Washer 10 MAINTENANCE Base Fork Bolt Part No. 1145810 41 Electric Portable Patient
  • Invacare RPL450-2 | Owners Manual - Page 42
    Reliant Scale RLS6 The Reliant Scale is a compact precision scale system designed specifically for the Invacare Patient Lift System. ƽ WARNING DO NOT install or use this equipment without first reading and understanding these instructions . Electric Portable Patient Lift 42 Part No. 1145810
  • Invacare RPL450-2 | Owners Manual - Page 43
    ) Pinch Guard 11 ACCESSORIES Locknut (Save for installing Scale) *450 lb Swivel Bar Nylon Washers Swivel Bar Pin  FIGURE 11.1 Removing the Swivel Bar *600 lift swivel bar not shown. Part No. 1145810 43 Electric Portable Patient
  • Invacare RPL450-2 | Owners Manual - Page 44
    from the lift during ALL installation procedures. 1. Position the load cell assembly of the Reliant Scale into  Use 1/4-inch nylon washer. 2. Secure the Reliant Scale to the boom mounting bracket with a shoulder .2. ƽ WARNING After ANY adjustments, repair or service and BEFORE use, make sure all
  • Invacare RPL450-2 | Owners Manual - Page 45
    Boom Mounting Bracket Nylon Washer Reliant Scale Reliant Scale Mounting Screw Shoulder Bolt Nylon Washer Nylon Washers Load Cell Assembly FIGURE 11.2 Installing the Reliant Scale 11 ACCESSORIES DETAIL "B" Locknut Swivel Bar Swivel Bar Pin Part No. 1145810 45 Electric Portable Patient Lift
  • Invacare RPL450-2 | Owners Manual - Page 46
    shown in the display window to notify when battery is low. Display Window Operation Keys lb kg ZERO LOCK ON OFF ZERO UNITS LOCK UNLOCK Reliant Scale Model RLS6 CAPACITY 600 LB, 272 KG By DETECTO To Operate: 1. Attach sling. 2. Press ON key. 3. Press ZERO key
  • Invacare RPL450-2 | Owners Manual - Page 47
    supported by the lift. For patient lifting instructions, refer to Lifting the Patient on page 24. 6. Note the weight display. 7. When the weight display becomes stable press the LOCK button to lock the weight display. This will be indicated by the word "LOCK" appearing in the display window. Part
  • Invacare RPL450-2 | Owners Manual - Page 48
     Should it be necessary to unlock the weight while the patient is still supported by the lift, the UNLOCK button may be pressed. The weight will unlock and the word Reinstall the battery door. Battery Door 9V Battery Arrow Assembled Scale Electric Portable Patient Lift 48 Part No. 1145810
  • Invacare RPL450-2 | Owners Manual - Page 49
    Reliant Scale. For removing the patient instructions refer to Operation on page 20. For sling detachment instructions refer to Lifting the Patient on page 24. 2. With the Reliant - support 50 pounds of calibrated weight from the scale and press the ZERO key. B. FOR CAL2 OPTION - support 200 pounds
  • Invacare RPL450-2 | Owners Manual - Page 50
    . Contact Invacare for Service at 1-800-333-6900 CAL OCAP CALIBRATION REQUIRED - Indicates improper stored calibration data, calibration is necessary. OVER CAPACITY - Indicates a weight exceeding the capacity has been loaded on the scale. Electric Portable Patient Lift 50 Part No. 1145810
  • Invacare RPL450-2 | Owners Manual - Page 51
    Notes NOTES Part No. 1145810 51 Electric Portable Patient Lift
  • Invacare RPL450-2 | Owners Manual - Page 52
    Part No. 1145810 Rev B - 05/11 Invacare Corporation USA One Invacare Way Elyria, Ohio USA 44036-2125 800-333-6900 www.invacare.com Canada 570 Matheson Blvd E Unit 8 Mississauga Ontario L4Z 4G4 Canada 800-668-5324
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

This manual MUST be given to the user of the product.
BEFORE using this product, read this manual and save for future reference.
User Manual
EN
Invacare
®
Reliant™ 450
RPL450-2
Invacare
®
Reliant 600
RPL600-2