    service technician. No attempt shall be made to convert the appliance from the gas specified on the model Install a manual gas line instructions provided for it here. • Range must be connected to the proper electrical voltage and frequency as specified on the model/serial/rating plate. The model
  • KitchenAid KFGD500EWH | Dimension Guide - Page 2
    : If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface. Range may be installed with zero clearance to combustible construction at the rear and on
  • KitchenAid KFGD500EWH | Dimension Guide - Page 3
    ÉLECTRIQUES Pour installer la cuisinière de façon appropriée, il faut établir le type de raccords électriques qui sera utilisé et suivre les instructions de ce document. • La cuisinière doit être alimentée par une source d'électricité et une tension appropriées, comme spécifié sur la plaque
  • KitchenAid KFGD500EWH | Dimension Guide - Page 4
    indiquées à des fins de planification uniquement. Pour des détails complets, voir les Instructions d'installation fournies avec le produit. Spécifications indiquées sous réserve de modifications. ®/TM ©2019 KitchenAid. All rights reserved. Used under license in Canada. Tous droits réservés. Utilis
  • 1
  • 2
  • 3
  • 4

30" (76.2 cm) Freestanding Dual Fuel Range
Page 1 of 4
Because Whirlpool Corporation policy includes a continuous commitment
to improve our products, we reserve the right to change materials and
specifications without notice.
Dimensions are for planning purposes only. For complete details,
see Installation Instructions packed with product.
Specifications subject to change without notice.
W11267664A
Ref. W10694069C
08/19
PRODUCT MODEL NUMBERS
KFGD500E
GAS SUPPLY REQUIREMENTS
Type of Gas:
Natural Gas:
• This range is factory set for use with Natural gas. See “Gas
Conversions” section. The model/serial/rating plate is located on the
oven frame behind the top left side of the oven door has information
on the types of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local gas supplier.
Propane gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas specified
on the model/serial/rating plate for use with a different gas without
consulting the serving gas supplier. See “Gas Conversions” section.
Gas Supply Line
• Provide a gas supply line if 3/4" (1.9 cm) rigid pipe to the range
location. A smaller pipe on longer runs may result in insufficient gas
supply. With propane gas, piping or tubing size can be 1/2" (1.3 cm)
minimum. Usually, propane gas suppliers determine the size and
materials used in the system.
NOTE:
Pipe-joint compounds that resist the action of propane gas
must be used. Do not use plumbing tape.
Flexible metal appliance connector:
• If local codes permit, a new CSA design-certified,
4 to 5 ft (122 to 152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D.
(inside diameter), flexible metal appliance connector may be used for
connecting range to the gas supply line.
• A 1/2" (1.3 cm) male pipe thread is needed for connection to the female
pipe threads of the inlet to the appliance pressure regulator.
• Do not kink or damage the flexible metal tubing when moving the
range.
• Must include a shut-off valve:
Install a manual gas line shut-off valve in an easily accessible location.
Do not block access to shut-off valve. The valve is for turning on or
shutting off gas to the range.
PRODUCT DIMENSIONS
A. 35°" ± 1/8" (90.8 ± 0.3 cm) cooktop height (minimum) with leveling
legs screwed all the way in**
B. Model/serial/rating plates (located behind the control panel)*
C. 47²
/
8
"± 1/8" (120.3 ± 0.3 cm) overall height (minimum) with leveling
legs screwed all the way in**
D. 28³" ± 1/4" (72.4 ± 0.6 cm) depth with handle
E. 26´
/
8
" ± 1/8" (66.4 ± 0.3 cm)***
F. 29
15
/
16
" ± 1/16" (76.0 ± 0.2 cm) width
* Model/serial/rating plates may be rotated up from behind the control
panel for viewing front the front of the range.
** Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
*** Excludes handle. Dimension given is from wall to front of oven door
and will vary based on electronic outlet receptacle installation.
ELECTRICAL REQUIREMENTS
To properly install your range, you must determine the type of electrical
connection you will be using and follow the instructions provided for it
here.
• Range must be connected to the proper electrical voltage and
frequency as specified on the model/serial/rating plate. The model/
serial/rating plate is located behind the control panel. Refer to the
figure in "Product Dimensions" in the "Location Requirements" section.
• This range is manufactured with a 4-wire power supply cord rated at
240 V, 40 A, rated at 194°F (90°C) and investigated for use with this
range.
Range Rating*
Specified Rating of Power Supply
Cord Kit and Curcuit Protection
120/240 V
120/208 V
Amperes
Temperature Rating
8.8 – 16.5 kW
7.8 – 12.5 kW
40 or 50
194°F (90°C)
16.6 – 22.5 kW
12.6 – 18.5 kW
50
194°F (90°C)
* The NEC calculated load is less than the total connected load listed
on the model/serial/rating plate.
A. Gas supply line
B. Shut-off valve “open” position
C. To range
A
B
C
A**
F
E***
D
C**
B*