Kyocera KM-2560 PRESCRIBE Commands Command Reference Manual Rev 4.8
Kyocera KM-2560 Manual
View all Kyocera KM-2560 manuals
Add to My Manuals
Save this manual to your list of manuals |
Kyocera KM-2560 manual content summary:
- Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 1
PRESCRIBE Commands Command Reference - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 2
asked to excuse any omissions or errors in the present edition. No responsibility is assumed if accidents occur while the user is following the instructions in this manual. No responsibility is assumed for defects in the printer's firmware. Regarding Tradenames: PRESCRIBE is a registered trademark - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 3
three printers, you need to acquire a multi-user license agreement which can be obtained from Monotype Imaging. Monotype Imaging retains all rights, title and interest to the Software and Typefaces and no rights are granted to you other than a License to use the Software on the terms expressly set - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 4
This page is left blank intentionally iv - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 5
Commands by Function 2 Access Commands 2 Print System Setting Commands 2 Margin and Page Portrait/Landscape Orientation Commands TaBle] Assign user-defined character table --------- 14 ALTB C - [ALlocate TaBle] Convert character code 15 ALTB D - [ALlocate TaBle] Delete user-defined character - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 6
85 DZP - Draw to Zero-relative Position 87 EMCR - Enable MaCRo depending on paper source 89 ENDB - END a two-dimensional Barcode string 91 ENDC - END carbon DIRection 100 FILL - FILL closed path 101 FLAT - set FLATness 104 FLST - print Font LiST 105 FOLD - FOLD printed pages 107 FONT - change - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 7
- select Paper SouRCe 213 PXPL - PiXel PLacement 214 !R! - PRESCRIBE start sequence 215 RCLT - Rotated CoLlaTion 217 RDMP - Received-data DuMP 218 RES - RESet 220 RESL - select RESoLution 222 RGBL - control RGB Level 223 RGST - offset ReGiSTration 225 RPCS - Return to Previous Code Set 226 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 8
Current PaLette 278 SCRC - Set Command Recognition Character 279 SCS - Set Character Spacing 281 SCSZ - Set Custom paper SiZe 282 SCU - Save Current Unit 283 SDP - Store Dash Pattern 285 SEM - Set Emulation Mode 287 SETF - SET alternate Font 288 SFA - Set bitmap Font Attributes 290 SFNT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 9
0 - select barcode type/reset all other XBCP parameters---------- 365 XBCP 1 - specify narrowest element width 366 XBCP 2 - specify error correction level by percentage 367 XBCP 3 - set error correction level 368 XBCP 4 - set data code word rows 369 XBCP 5 - set data code word columns 370 XBCP - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 10
Contents-vi - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 11
PRESCRIBE Command Reference - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 12
RES RESet 220 RESL select RESoLution 222 RGST offset ReGiSTration 225 RPU Return to Previous Unit 233 SCSZ Set Custom paper SiZe 282 SCU Save Current Unit 283 SEM Set Emulation Mode 287 SIR Set Image Refinement level 304 SPSZ Set Paper SiZe 324 STAK select paper STAcKer - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 13
orientation can be reset by using the RES command. Command Function Page SBM Set Bottom Margin 264 SLM Set Left Margin 307 SLPP Set Lines Per Page 310 SPL Set Page Length 320 SPO Set Page Orientation 322 SPW Set Page Width 326 SRM Set Right Margin 328 STM Set Top Margin - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 14
. Additionally, there are commands to download fonts to the printing system from an external source, and to generate fonts. Command Function Page ALTB A [ALlocate TaBle] Assign user-defined character table 14 ALTB C [ALlocate TaBle] Convert character code 15 ALTB D [ALlocate TaBle] Delete - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 15
SCCS Save Current Code Set 268 SCF Save Current Font 270 SETF SET alternate Font 288 SFA Set bitmap Font Attributes 290 SFNT Select current FoNT by typeface 294 TPRS Text PaRSing 351 Fonts are more fully explained in Chapter 4 of the Technical Reference manual. Cursor Movement - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 16
print results. It may be possible to correct the problem by removing some of the downloaded fonts or by simplifying the graphic. To determine current generate Fill PATtern 110 GPAT set Gray PATtern 122 PAT select fill PATtern 184 PIE draw PIE chart 199 SPD Set Pen Diameter 318 XPAT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 17
PCZP in Path, Curve to Zero-relative Position 188 PDIR set Print DIRection 190 PDRP in Path, Draw to Relative 285 SIMG Set IMaGe model 298 SLJN Set Line JoiN 305 SMLT Set Miter LimiT 313 240 SRO Set Raster Options 330 SROP Set Raster OPeration 332 STR SeT dot Resolution - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 18
color palette 180 RGBL control Set kcGl Pen Color 297 SIMP create SIMPle color palette 302 SMNT Set MoNiTor simulation 315 SPAL Select PALette 317 Barcode Commands Barcodes conforming to various specifications dimensional barcode select barcode type/reset all other XBCP parameters, - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 19
EMCR Enable MaCRo depending on paper source 89 ENDC END carbon or CompactFlash card, or a hard disk, is installed in the printing system, the following commands can List 254 [Read/Write Resource File] set hidden file 255 [Read/Write Resource File] Read 256 [Read/Write Resource File] set - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 20
equipment. Command Function Page APSG Assign Paper Source Group 27 ASTK Assign STacKer trays 207 SSTK select Sorter STacKer 334 STPC set STaPle Counter 340 STPL STaPLe 341 e- DiSK 49 JOBD JOB Deletion 132 JOBL print JOB List 134 JOBO JOB Output 136 JOBP JOB, print with - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 21
printed by the STAT command or by pressing the panel keys. The User's Manual provides a full description of the control panel functions. Many PRESCRIBE commands can be embedded commands within word processing software. This support depends upon the emulation mode and the software. See Emulation of - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 22
PRESCRIBE Command Reference ACLI - Add CoLor by Index COLOR Format ACLI index, color1, color2, color3; Parameters index: integer from 1 to 255 color1: value for red, integer from 0 to 255, in RGB color space value for lightness, number from 0.0 to 100.0, in L*a*b color space color2: value - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 23
File !R! RES; DAM; UNIT C; SFNT 'AntiqueOlive-Bd', 20; CPAL C; SPAL 1; CID 0, 1; ACLI 1, 0, 0, 255; ACLI 2, 0, 255, 0; ACLI 3, 255, 0, 0; MZP 1, 1; SCOL 1; TEXT 'This line is printed in blue.'; MZP 1, 2.4; SCOL 2; TEXT ' - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 24
Command Reference ALTB A - [ALlocate TaBle] Assign user-defined character table Format ALTB A, table-id; Parameter table-id: number identifying the character table assigned to the resident font, from 1 to 65535 Function The ALTB A command assigns the user-defined character table to the current - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 25
the Euro currency symbol ''a (character code 186 for Roman-9 symbol set).'' !R! SFNT "TimesNewRoman", 14; CSET 4U; CMNT Roman-9; ALTB G, 56535, 1; ALTB C, 56535, 92, 186; ALTB A, 56535; TEXT "The Euro currency is symbolized as \."; ALTB R, 56535; CMNT Release user table; PAGE; EXIT; Printout 15 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 26
-id: number identifying the character table, from 1 to 65535, to be deleted Function The ALTB D command deletes the character table defined by the user. If the table to be deleted is currently allocated to the resident font (see ALTB A), terminate the allocation by using ALTB R before deleting. It - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 27
] End defining combination characters Format ALTB E; Parameter None Function This command signals the end of defining combination characters in an already generated user-defined character table which was started by the ALTB S command. (page 20). The registered combined characters can be printed by - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 28
id, table-format; Parameters table-id: table ID number: 1 to 65535 table-format: 1 = 1-byte, character codes 0 to 255 2 = 2-byte, character codes 0 to 65533 Function The ALTB G command generates a user-defined table in either 1-byte or 2-byte format. If the same table ID number already exists, the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 29
table-id; Parameter table-id: number identifying the character table to be released Function The ALTB R command terminates the assignment of the user-defined character table for the current resident font. It is also possible to terminate the assignment of all userdefined character tables by using - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 30
which the combination character is defined. 1-byte code = 0 to 255; 2-byte code = 0 to 65533, or in hexadecimal notation ($xxxx). width: overall width of the combined character, represented by number from 1 to 65535 in units where the width of the resident font character is 1000 height: overall - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 31
JIS code width: character width: the value from 1 to the character width specified by ALTB S (page 20) height: character height: the value from 1 to the character height specified by ALTB S (page 20) x-coordinate: X coordinate of the reference point, integer value calculated in 1000 unit basis - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 32
PRESCRIBE Command Reference File !R! res; unit c; SFNT 'TimesNewRoman', 48; ALTB G, 1000, 1; ALTB A, 1000; ALTB S, 1000, 64, 1800, 1000; ALTB T, 77, 700, 700, 0, 700; CMNT M; ALTB T, 65, 700, 700, 630, 700; CMNT A; ALTB T, 85, 700, 700, 1050, 700; CMNT U; ALTB T, 73, 700, 700, - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 33
font to a font designated by an alternate number. The actual font assigned to this alternate number is set by a previous SETF command. The alternate number can be a bitmap font number or a number specifically assigned to the scalable font using the SFNT command (See File on the next page). If no - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 34
PRESCRIBE Command Reference File !R! RES; SFNT "Helvetica-Nr", 12, 1000; SFNT "TimesNewRoman-It", 11, 1001; SETF 1, 1000; SETF 2, 1001; MCRO BIBLIO; ALTF 1; TEXT %1, E; TEXT " ", E; ALTF 2; TEXT %2, E; TEXT " ", E; ALTF 1; TEXT %3, N; ENDM; ALTF 1; TEXT "Bibliography", N, U; TEXT, N; CALL BIBLIO, - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 35
the CALL command; therefore, the user should refer to the section on unit of measurement, underline parameters, and fill pattern. When the automatic macro is enabled with mode T, the printing system settings are modified according to the parameter settings contained in the macro. Color specifications - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 36
PRESCRIBE Command Reference File !R! RES; MCRO CROPMARK; UNIT C; MZP 2.46, 3.96; SCP; SCP; SCP; MRP -.635, 0; DRP -1.9, 0; RPP; 0; DRP -1.9, 0; RPP; MRP 0, .635; DRP 0, 1.9; RPP; ENDM; AMCR E, CROPMARK; PAGE; UNIT C; SLM 3.6; STM 5.2; EXIT; The text starts here. Printout Related Command CCPY 26 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 37
printer driver. Example To set six paper cassettes into group 1 (cassettes 1 and 4), group 2 (cassettes 2 and 5), and group 3 (cassettes 3 and 6), respectively: !R! APSG 1,2,3,1,2,3; EXIT; In this example, when cassette 1 becomes empty, printing will continue using cassette 4 which is the other part - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 38
1, for example), the result is a line arc. The line thickness is the difference between the two radii, rather than the value designated by the SPD (set pen diameter) command. The ARC command does not draw the boundary of the filled-in area. 28 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 39
ARC File !R! RES; UNIT C; MAP 5, 8; PAT 52; ARC 1, 2, -45, 45; MAP 5, 10; PIE 2, 0, 10, 20, 30; ARC 0, 2, 0, 60; PAT 20; ARC 0, 2, 60, 180; PAT 10; ARC 0, 2, 180, 360; PAT 1; NEWP; PMZP 4, 2; PARC 4, 3, 1, 90, 270; PARC 5, 4, 1, 180, 360; PARC 6, 3, 1, 270, 90; PARC 5, 2, 1, 0, 180; STRK; MRP 0.6, - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 40
PRESCRIBE Command Reference Printout Related Command PARC 30 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 41
resident font. The external characters should be generated and downloaded in the printing system as an external font by using the LDFC or LDFN command. For the print systems supporting 2-byte font system, if the user-defined font is a 1-byte code font, it is assigned to the current resident roman - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 42
in groups so that the sorter can be shared among the multiple users. Each parameter represents the last tray in each group of trays. 6; is equivalent to ASTK 2, 4, 6, (bottom tray number);. The tray group setting made by ASTK is stored indefinitely in the printing system's permanent memory while the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 43
ASTK File The following command sequence delivers print jobs to trays 4, 5, 6, and 7 (the second group). !R! FRPO S0, 1; CMNT Enter multiple sorter mode; ASTK 3, 7, 9; CMNT Create three groups; MID 2; CMNT Send the output to 2nd grp.; SSTK; CMNT Sort; EXIT; Related Commands CSTK, MID, MSTK, SSTK 33 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 44
12 = EAN-13 (Truncated JAN) 13 = DUN-14 (Distribution Unit Number, EAN) 14 = DUN-16 (Distribution Unit Number, EAN) 15 = MSI with no check digit 16 = = Code 128 (manual mode change) 24 = Code 128 (auto mode change) 25 = Code 11 with only 'c' 26 = Code 11 with both 'c' and 'k' checksum 27 = Code 93 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 45
= CUSTOM CODE (Japan)1 . Default value is 1.52cm (0.6 inches, 180 dots). The unit of measurement is determined by the UNIT command. Minimum value 0.254cm (0.1 inch, command converts a string to a barcode and prints it. The specification of the type, flag and string parameters is necessary. After - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 46
PRESCRIBE Command Reference Table 20 Characters that can be used Type Max Characters to be used Default 0 11 0123456789 0 1 13 0123456789 0 2 16 0123456789 0 3 13 0123456789 0 4 18 0123456789 0 5 22 0123456789 0 6 25 0123456789 0 7 29 0123456789 0 8 6 0123456789 0 9 8 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 47
measurement in order to avoid the translation error by the barcode reader. In the example below, the length of the short bar is specified as 1.5cm and the tall bar as 1.7cm. !R! UNIT D; BARC 8, Y, '123456', 180, 200; PAGE; EXIT; Width and space of the bar It is possible to adjust the widths of - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 48
and printing the pages two-up on a sheet of paper. Booklet printing requires the hard disk to be installed in the printing system. a = First page b details on page size, refer to the SPSZ command page in this manual. The document must have the same page size for all pages. If the double size paper - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 49
to left This command is not supported by some photocopier models. The following command sequence prints a copy of a 12-page A4 document in booklet mode, folding the stack in the middle. The printing system will require A4-R paper to be loaded. !R! RES; SPSZ 8, 5; UNIT C; BKLT 1; DUPX 2; FOLD; SFNT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 50
PRESCRIBE Command Reference BLK - draw filled-in BLocK Format BLK width, depth[, option]; Parameters width: width of the block depth: depth of the block option: B = Leave the cursor unmoved (Default) H = Move the cursor to the horizontally adjacent corner V = Move the cursor to the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 51
BLK File !R! RES; UNIT C; MAP 5, 5; PAT 20; BOX 4, 1; BLK 4, 1; MRP 0, 1.5; BOX 4, 1; BLK 4, 1; MRP .9, .6; SFNT "Helvetica-Nr"; TEXT 'OVERPRINTING'; MRP 0, 5; PAT 29; BOX 1, -4; BLK 1, -4, H; PAT 39; BOX 1, -3; BLK 1, -3, H; PAT 49; - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 52
size with one corner at the current cursor position. The line thickness is designated by the SPD (set pen diameter) command. The size and thickness is measured on the basis of value established in the UNIT command. The cursor is moved as specified by the option. If the option is omitted, the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 53
BOX MAP 4, 0; SCP; SFNT "Helvetica-Nr", 10; BOX 4, 2, L; TEXT 'Text printed with option L'; RPP; BOX 4, 2, N; TEXT 'Text printed with option N'; PAGE; EXIT; Printout 43 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 54
PRESCRIBE Command Reference CALL - CALL macro Format CALL[ repeat-count] macro-name, parameter-value, ...; Parameters repeat-count: number of times the macro is to be executed macro-name: name defined by a MCRO command parameter-values: values given to the dummy parameters in the macro - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 55
File !R! RES; UNIT C; SLS .5; CMNT Requires BX and SCREEN macros; CMNT See ENDM command page; MAP 9, 3; CALL BX; MAP 7, 4; CALL 5 BX; MAP 5, 5; CALL 9 BX; MAP 8, 6; CALL SCREEN, 2.2, 1.7; MAP 8.6, 7; - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 56
copy is executed, the copy count (COPY command) is forced to be 1. To apply no overlay to a specific page, describe only the TERM command in the line corresponding to the page. Note that the same paper source as the previous line is applied to that line. For example: CCPY E; PSRC 2; AMCR E, CROPMARK - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 57
'Helvetica-Bd',14; TEXT 'Registration Form', L; SFNT 'Helvetica', 9; TEXT 'Please provide your personal details:'; MRP 0, .2; BOX 6, 1; MRP 0, .35; TEXT ' Your Name'; ENDM; MCRO MAIL; UNIT C; SFNT 'Helvetica-Bd',14; TEXT 'Mailing Information', L; SFNT 'Helvetica', 9; TEXT 'Shipping Department Use - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 58
PRESCRIBE Command Reference Printout 48 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 59
CDSK CDSK - Check hard DiSK Format CDSK; Parameter None Function The CDSK command verifies data in the hard disk (garbage collection). It deletes garbage jobs such as page image data that were accidentally generated in the hard disk and normally inaccessible for deletion. File !R! CDSK; EXIT; 49 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 60
PRESCRIBE Command Reference CID - Configure color-Image Data COLOR Format CID color-space, encoding; Parameters color-space: 0 = Device-dependent RGB (Default) 1 = Device-dependent CMY 2 = Void 3 = CIE L*a*b encoding: Pixel encoding 1 = Indexed by Pixel (Default) 3 = Direct by Pixel Function - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 61
CID File !R! RES; DAM; UNIT C; SFNT 'Helvetica-Bd', 20; CPAL C, 1; SPAL 1; CID 0, 1; CMNT RGB Color Space used; ACLI 1, 0, 0, 255; MZP 1, 1; SCOL 1; TEXT 'An RGB color palette is used.' CID 3, 1; CMNT L*a*b - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 62
by the SPD command. A circle can also be drawn by using the path mode graphics. Refer to the PARC command. File !R! RES; UNIT C; SLS .5; SPD .01; MAP 10, 1; CIR .1; MRP 0, .1; CIR .2; MRP 0, .2; CIR .4; MRP 0, .4; CIR .8; MRP 0, .8; SPD .02; CIR 1.6; MRP 0, 1.6; CIR 3.2; MRP 0, 3.2; SPD .2; CIR - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 63
CIR Printout 53 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 64
Command Reference CLIP - CLIP current path Format CLIP [clip-mode]; Parameter clip-mode: 1: EO clip 2: Non-zero winding clip Function The CLIP command sets the current path as the clipped path. After this command is issued, no painting is done outside the area of the path. Executing this - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 65
measured from the top and left edge limits in the units designated by the UNIT command. If the parameters are omitted, the rectangle the printing system exchanges the coordinate values with each other. The printing system resets the size of the rectangular clipping path to be equal to the maximum - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 66
PRESCRIBE Command Reference File !R! RES; UNIT C; NEWP; SPD 1; PMRA 6, 9, 3, 0; PAT 1; PARC 6, 9, 3, 0, 360; CLPR 3, 6, 9, 12; STRK; PAGE; EXIT; Printout 56 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 67
Closure can be made either explicitly, by means of the CLSP command, or implicitly by means of the FILL (FILL current path) command. File !R! RES; UNIT C; NEWP; CMNT The 1 st path below is stroked without closing; SPD .25; PMZP 5, 10; PMRA 5, 10, 1, 90; PARC 5, 10, 1, 90, 270; PARC 7, 10, 1, 270, 90 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 68
PRESCRIBE Command Reference Printout Related Command NEWP 58 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 69
CMNT CMNT - CoMmeNT Format CMNT string; Parameter string: any character string Function The CMNT command adds a character string, typically a comment explaining the purpose of the following PRESCRIBE commands. The CMNT command statement will be ignored by the printing system. Although character - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 70
PRESCRIBE Command Reference CMOD - Color MODe COLOR Format CMOD mode; Parameter mode: color mode: 0 = Monochrome 1 = Color (Default) Function The CMOD command switches between monochrome and color modes. In monochrome mode, other color commands are still enabled, but printing is converted to - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 71
COPY command or by issuing a reset command. For best results, place the copy command near the start of a job or at the top of a page. If two or more copy commands are placed on the same page, the last one will be recognized. File !R! RES; SLM 0.5; UNIT P; SFNT 'Helvetica-Bd', 14.4; SLS - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 72
PRESCRIBE Command Reference Printout 62 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 73
applied to palette of ID 0. No check is made whether the palette ID number given already exists for another palette. The palette ID number is reset to 0 by RES command. Mode A deletes all existing palettes and brings the default palette back to the default state (ID 0). Note that non-active palettes - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 74
PRESCRIBE Command Reference CPTH - Character PaTH Format CPTH 'string'; Parameter string: any character string except from ASCII code 31 (hex 1F) and lower Function The CPTH command constructs a path which adds the outlines of characters to the current path. When stroked or filled, - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 75
5 6J = MS Publishing 6M = Ventura Math 6N = ISO8859/10 Latin 6 6S = ISO 85 Spanish 7J = Desktop 8G = Greek-8 8M = Math 8 8Q = PC Set 1 IBM 8T = Turkish-8 8U = Roman-8 9E = Windows Latin 2 9G = Windows 3.1 Latin/Greek 9J = PC-1004 9L = Ventura ITC Zapf Dingbats 9N = ISO Latin 9 9Q = PC Extension 65 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 76
14R = PC Ukrainian 15U = Pi Font 16U = PC-857 17U = PC 852 18N = ISO-10646 18U = PC-853 Turkish/Latin 3 19L = Windows 3.1 Baltic† 19M = Symbol (Symbol-Set-SWM font only) 19U = Windows Latin 1 20U = PC-860 Portugal† 21U = PC-861 Iceland† 23U = PC-863 Canada-French† 24Q = PC-8 Polish Mazovia† 25U = PC - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 77
CSET Function 'Symbol set' refers to a specific group of alphabetic, numeric, and symbolic characters. The CSET command summons the symbol set to suit the various languages with the current font. The factory default symbol set is 0U (US ASCII). When the FSET command is used to select a font, the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 78
only when the optional sorter is installed to the printing system. It instructs the printing system to deliver printed pages sorter's bulk tray (if available). This command is irrelevant to certain combination of photocopier models and option finisher models. Note File !R! RES; CSTK 1, 2; COPY - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 79
, the text is underlined. The underline thickness and location can be set by the SULP command. The string is not centered between the right as a whole may not be longer than 255 characters. Carriage-return and linefeed codes in the string are ignored. File !R! RES; SLPI 3; SFNT "Helvetica-Bd - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 80
PRESCRIBE Command Reference Printout 70 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 81
font numbers assigned to scalable fonts by the SFNT command from the printing system's memory. This enables the user to make room for new fonts, macros, and graphics. File !R! UNIT P; SLS 16; SFNT 'Helvetica-Bd', 15, 2000, 277, 2, 0; SFNT 'Helvetica', 15, 2001, 277, 1, .5; FONT 10; TEXT '1. FAREWELL - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 82
macro definitions made by using the PRESCRIBE MCRO command from the printing system's memory. This enables the user to make room for new macros, fonts, or graphics. File !R! RES; UNIT C; CMNT Print ENDM file first.; SFNT "Helvetica-Bd"; MAP 5, 4; CALL SCREEN, 9.2, 1.7; MAP 7, 5; TEXT 'This text is - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 83
to the top and left margins. The thickness of the line is designated by the SPD (set pen diameter) command. The coordinates and line thickness are measured in the units designated by the UNIT command. The coordinates may be positive or negative. Negative coordinates cause the line to extend outside - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 84
PRESCRIBE Command Reference Printout 74 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 85
non-resident font from the printing system's memory. This enables the user to make room for new fonts, macros, and graphics. The available can be viewed on a status page, available by executing the STAT command. File !R! UNIT P; SLS 16; SFNT 'Helvetica-Bd', 15, 2000, 277, 1.5, 0; SFNT 'Helvetica - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 86
PRESCRIBE Command Reference DELM - DELete Macro Format DELM macro-name; Parameter macro-name: name defined by a previous MCRO command Function The DELM command deletes a specified macro definition from the printing system's memory to make room for new macros, fonts, or graphics, or so that the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 87
File !R! UNIT C; MCRO BX; SPD .05; BOX .8, -.8; MRP 1, 0; ENDM; MCRO SCREEN 23, .30, 0, 90; MRP .27, 0; DRP 0, %2; MRP -.27, 0; ARC .23, .30, 90, 180; RPP; MRP 0, .25; DRP 0, %2; MRP .25, 0; ARC .23, .30, 180, 270; MRP 0, .27; DRP %1, 0; RPP; ENDM; SFNT "Helvetica-Bd"; MAP 5, 4; CALL SCREEN, 9.2, - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 88
20 (11 to 20 are for user-defined patterns.) Function The DPAT command specifies the pattern of alternating black and white dashes to stroke the current path. The resident patterns range in value between 1 and 10. Refer to resident patterns list on - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 89
DPAT Printout Related Command SDP 79 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 90
to a specified relative position. The thickness of the line is designated by the SPD (set pen diameter) command. The coordinates and line thickness are measured by the value designated by the UNIT command. Multiple pairs of coordinates may be specified. The printing system then draws a connected - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 91
DRP Printout Related Command PDRP 81 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 92
the current cursor position, with the thickness designated by the SPD command. This command is ignored if placed within a path. File !R! RES; UNIT C; MAP 2, 11; DRPA 2, 72; DRPA 2, 0; DRPA 2, 144; DRPA 2, 72; DRPA 2, 216; DRPA 2, 144; DRPA 2, 288; DRPA 2, 216; DRPA 2, 0; DRPA 2, 288; PAGE; EXIT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 93
DRPA Printout 83 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 94
edge binding Function The DUPX command is effective only when the option duplexer is installed to the printing system. It instructs the printing system to select or deselect duplex printing and sets the binding mode. Portrait, long-edge Portrait, short-edge Landscape, long-edge Landscape, short - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 95
back side Function The DXPG command is effective only when the option duplexer is installed to the printing system. It ends printing on the current page in the same form feed. However, unlike the form feed, it also selects the paper side, front or back, on which printing of the ensuing page is - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 96
Initiates a PRESCRIBE command sequence; RES; CMNT Causes a page break and resets parameters; DUPX 2; CMNT Selects duplex mode, short-edge binding; SPO side of the page !R! DXPG 0; CMNT Ends current page (front side of the paper); EXIT; This text prints upside-down on the reverse side of the page !R! - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 97
relative to the top and left edge limits of the paper. The thickness of the line is designated by the SPD (set pen diameter) command. The coordinates and line thickness are measured in the value designated by the UNIT command. The coordinates should be positive or zero. Negative coordinates - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 98
PRESCRIBE Command Reference Printout Related Command PDZP 88 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 99
= print-side], [repeat-count] macro-name [, parameter...]; Parameters mode: E = enable automatic macro D = disable automatic macro paper-source: 0 = multi-purpose feeder 1 = cassette 1 (printing system's cassette) 2 = cassette 2 3 = cassette 3 4 = cassette 4 5 = cassette 5 6 = cassette 6 (bottom - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 100
Function The EMCR command allows separate auto macros to be assigned for each of the separate paper sources. In duplex printing, it is also possible to assign separate auto macros for both the the auto macro, use EMCR D. Note that EMCD D does not require other parameters such as paper-source. 90 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 101
symbols will be output. When ENDB is used immediately after XBCP 18 is executed, it is used alone, without association with XBAR or XBUF. For details on two-dimensional barcodes, see Section 5.2. of the Technical Reference - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 102
PRESCRIBE Command Reference ENDC - END carbon Copy Format ENDC; Function The ENDC command ends definition of the CCPY E command sequence. For details, refer to the CCPY command. 92 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 103
ENDD ENDD - END Dump Format ENDD; Parameter None Function The ENDD command ends a hexadecimal dump initiated by the RDMP (Received-data DuMP) command and returns to the PRESCRIBE command mode. File See RDMP on page 218. Related Command RDMP 93 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 104
definition and returns to the PRESCRIBE command mode. File !R! RES; DAM; UNIT C; MCRO BX; SPD .05; BOX .8, -.8; MRP 1, 0; ENDM MRP .27, 0; DRP 0, %2; MRP -.27, 0; ARC .23, .30, 90, 180; RPP; MRP 0, .25; DRP 0, %2; MRP .25, 0; ARC .23, .30, 180, 270; MRP 0, .27; DRP %1, 0; RPP; ENDM; PAGE; EXIT; 94 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 105
Printout ENDM Related Commands CALL, DAM, DELM, MCRO 95 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 106
File The following example prints an illustrated crown using the RVRD and ENDR. !R! RES; DAM; DAF; UNIT C; SRO 1; MAP 5, 5; RVRD; 5, 0, 0, 7, 0, 0; 5, 0, 0, 24, 192, 0;5, 0, 0, 32, 32, 0; 5, 0, 0, 64, 16, 0; 5, 0, 0, 64, 16, 0; 5, 0, 0, 128, 8, 0; 5, 0, 0, 128, 8, 0; 5, 0, 0, 128, 8, 0; 5, 0, 0, 64 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 107
ENDR 5, 0, 160, 96, 80, 0; 5, 1, 24, 1, 136, 0; 5, 14, 134, 6, 23, 0; 5, 48, 65, 248, 32, 192; 5, 192, 129, 8, 16, 48; 5, 0, 64, 144, 32, 0; 5, 0, 32, 96, 64, 0; 5, 0, 16, 0, 128, 0; 5, 0, 32, 0, 64, 0; 5, 0, 16, 0, 128, 0; 5, 0, 8, 1, 0, 0; 5, 0, 6, 6, 0, 0; 5, 0, 1, 104, 0, 0; 5, 0, 0, 144, 0, 0; - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 108
a standard feature of the print systems that enables the user to reduce the amount of toner placed on the page which saves on printing costs. With put on a page, the last one is effective. The Ecoprint setting does not effect print speed. File !R! RES; SFNT "Helvetica-Bd", 24; SLPI 3; EPL 2; - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 109
EXIT EXIT - EXIT from PRESCRIBE mode Format EXIT [, E]; Parameter None Function When the printing system receives the EXIT command, it exits from the PRESCRIBE mode and treats the following information as characters to be printed. If the parameter E is added (EXIT, E;), the printing system ignores - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 110
's operational mode is cassette or manual feed. Printing on A4 and letter size paper can only be done widthwise in first mode. This command causes a page break. This command is irrelevant to paper cassettes and envelope feeders. The paper orientation setting is restored to the default orientation - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 111
point is deemed to be outside; otherwise the point is deemed to be inside the path. The way in which several filled-in parts are stacked with each other to produce transparent and opaque effects is controlled by the SIMG (Set IMaGe model) command. Related Commands FPAT, GPAT, PAT, SIMG, XPAT 101 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 112
PRESCRIBE Command Reference File !R! RES; UNIT C; SIMG 1; CMNT Drawing clusters; NEWP; PMZP 10, 12; PDRP -5.7, -1.75; PCRP 0, 0, 0, -3.4, 3.1, -3.6; CLSP; PAT 2; FILL; PMZP 10, 12; PDRP -2.6, -5.35; PCRP 0, 0, 2.5, -2.5, 4.9, .1; CLSP; PAT 3; FILL; PMZP 10, - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 113
FILL Printout 103 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 114
FLAT - set FLATness error tolerance of a straight line segment approximation of any portion of the curve. The printing system resets the flatness to 1 when it receives the RES command. File !R! RES; FRPO N8,0; CMNT 300 dpi; UNIT C; SPD 0.02; NEWP; CMNT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 115
FLST; Parameter None Function The FLST command prints a list of all resident and downloaded (user-defined) fonts in the printing system. The list provides information on each font such as font name, whether it is scalable or bitmap, font selection sequence using FSET, font ID, etc. The resident - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 116
PRESCRIBE Command Reference Sample of Font List Internal Scalable and Bitmapped Fonts List PRESCRIBE Font Name Scalable/Bitmap Password Selection [FSET] Font ID 106 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 117
when the optional document finisher having the booklet stitcher is installed to the printing system. This command is most conveniently used folded at its center in reference to the short edge of the paper. Folding and stapling File Paper sizes available for this mode include A4-R, letter-R, B4, A3 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 118
of the selected font. The scalable fonts, however, ignore the font mode setting. Line spacing must be specified by the user in this case using one of the line spacing commands (SLS, SLPI, etc.). File !R! RES; UNIT P; SFNT 'Univers-BdIt', 18, 2000; SFNT 'Univers-BdIt', 14, 2001; FONT 2000 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 119
Printout Related Commands ALTF, FLST, SETF FONT 109 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 120
. For printing system models that support 600/1200 dpi resolution printing, See Section 6.2. of the Technical Reference manual (FRPO B8). The printing system in the 1200 dpi resolution. For an all-white row, specify 0. The FPAT command for creating all white rows is specified below: FPAT 0, 0, 24, - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 121
File !R! RES; DAM; UNIT C; FSET 1p08V0s0b5T; MCRO PATTERN; FPAT %1, %2, %3, %4, %5, %6, %7, %8; BOX 5, 1; BLK 5, 1; MRP 0, 1.55; TEXT 'FPAT %1, %2, %3, %4, %5, %6, %7, %8;', L; ENDM; MAP 2, 2; SCP; CALL PATTERN, 3, 3, 0, 0, 0, 0, 0, 0; CALL PATTERN, 255, 0, 0, 0, 0, 0, 0, 0; CALL PATTERN, 1, 1, 1, - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 122
sets the various printing parameters stored in permanent memory. Each parameter is identified by a code consisting of a letter and a numeral, such as P1. Details can be reset to the factory-set values by the FRPO INIT (FRPO-INITialize) command. Note that the RES command does not reset those changes - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 123
Printout Related Command FRPO INIT FRPO 113 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 124
dependent parameters. For a list of the factory default values, see Chapter 6 of the Technical Reference manual. The FRPO INIT command causes a page break. To activate the changes made with the FRPO INIT command, turn the printer power off then on again or reset the printer using the control panel - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 125
FSET FSET - change current Font SETting by characteristic Format FSET spacing-pitch-height-style-weight-typeface; Parameters spacing: fixed or proportional spacing, followed by a terminator P: 0 = fixed font 1 = proportional font pitch: pitch - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 126
typeface values for option fonts, if installed, can be obtained by printing a font list. To print a font list, use the FLST command or the control printer, and the font's orientation. In the list below, the characteristics of font are listed in order of priority, from highest to lowest: Symbol set - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 127
set (the highest priority). All matches are next examined based on spacing. When the printer has reduced the matches to one font, it selects that font. Bitmap fonts have priority over scalable fonts. FSET enables the user regardless of the current unit setting (UNIT). Terminators following each - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 128
PRESCRIBE Command Reference File !R! UNIT P; SFNT 'Swiss742SWC-Roman', 10; SLS 12; EXIT; First, this line is printed in a 10 point Swiss742SWC-Roman font. !R! FSET 14V; SLS 16; EXIT, E; Let's see - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 129
changes the designated attributes to the values of the new font. The default value of the FTMD command depends on the emulation mode. The printer does not automatically change any attributes not designated by the FTMD command. If necessary, these attributes must be adjusted by other commands: SCS or - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 130
(Line Printer) 1 (IBM X-24E) or 2 (Diablo 630) 5 (Epson LQ-850) 6 (HP LaserJet) 8 (KC-GL) Font mode 15 0 Printer's action is automatically adjusted at each font change, but line spacing and page orientation are left alone; UNIT C; SLS 1; BOX .5, -.5; MRP 1, 0; FONT 47; TEXT 'Font 47, correctly - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 131
Printout FTMD 121 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 132
models that support 600/1200 dpi resolution printing, the default resolution generated by the GPAT command is 300 dpi; however, 600/1200 dpi can be selected using the FRPO B8 command. See Section 6.2. of the Technical Reference manual (FRPO B8). File !R! RES; UNIT C; MCRO GP; NEWP; GPAT %1; PDRP - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 133
GPAT Printout Related Commands FPAT, PAT 123 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 134
White and black are not colors. They are states in which all the light is reflected and absorbed respectively.) If each value of RGB is the same when processing images, the corresponding area can be represented by using either the same quantity of toner or only K toner using K toner alone. However - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 135
, and PackBit. Upon receipt of incompatible format and/or color-space data, this command is ignored. Width and height specifications are dependent on the current unit of measurement (UNIT). If the output image has a specified width of 0, the image will be printed in a width varying with the height - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 136
PRESCRIBE Command Reference c:¥> echo !R! STR 300; MZP 1,1; GRRD J,0,0; > lpt1 c:¥> copy /b fluit.jpg lpt1 c:¥> echo ;ENDG; PAGE; EXIT; > lpt1 Printout 126 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 137
number representing the color for hue adjustment: 0 = all colors 1 = R 2 = Y 3 = G 4 = C 5 = B 6 = M angle: angle of hue rotation in degrees: color = 0, - 180 to 180 (default = 0) color = 1 - 6, -10 to 10 (default = 0) type: object type Function The HUE command shifts all the pixels around the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 138
the vicinity of yellowish green will be yellow. Note that hues cannot be set to move beyond their next hues. R Y G C B M If this particular hue when all hues are rotated, the hues are controlled after they are reset to their default state. The HUE command is enabled for all color spaces, all - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 139
2 17 = Latin America code-set: 0 = Epson code set 1 = HP LaserJet code set 2 = Daisywheel code set 4 = IBM/Line Printer code set Function The INTL command selects a symbol set appropriate for the alphabet of a particular country. A symbol set includes the specific alphabetic and numeric characters - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 140
is 0: the standard US ASCII symbol set. The default code-set value appears as the U7 parameter. The factory setting is 0. Symbol Sets Available with INTL Country-code 0 (Epson) Code-set (emulation) 1 (HP LaserJet)a 2 (Daisywheel) 4 (IBM/Line Printer) 0b (US ASCII) LQ US ISO-6 ASCII Diablo - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 141
INTL File !R! CMNT This file will not print correctly in the IBM; CMNT emulation (mode 1); RES; INTL 2, 2; SLM 1; STM 2; SFNT "Helvetica", 14; EXIT; Diese [pfel sind eine ]berraschung! !R! PAGE; EXIT; Printout 131 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 142
for the mailbox, if any. (For details on aliasing and password-protection of the mailbox, see VMAL and VMPW, respectively.) Mode 9 deletes the mailbox and its contents at once. The alias and password for the mailbox is also deleted. Mode 15 resets all mailboxes to a clean state by deleting all - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 143
; To delete all temporary and permanent jobs in the hard disk: !R! JOBD; EXIT; To delete the jobs stacked in virtual mailbox number 3, which has the password of 9999: !R! JOBD 8, 3, 9999; EXIT; 133 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 144
list output Regardless of whether mailboxes contain any data, information is displayed for mailboxes which have been used at least once. The information displayed for each mailbox is: the mailbox (Bin) number, the alias set an error during data is written to the mailbox. An error log indicating - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 145
File To print a permanent job list: !R! JOBL 2; EXIT; JOBL 135 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 146
from 1 to 255, or alias password (mode 8 only): password for the mailbox Function The JOBO list of job names currently stored in the hard disk can be obtained by printing a job list (See JOBL on page 134). Settings an error is messaged on the operator panel display as follows: Hard Disk Error 99 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 147
will be forcibly sent to the stapler. The master password, if set previously by VMPW, is valid for all virtual mailboxes for which a password is set. An error will be displayed on the operator panel if no password or an incorrect password is specified. An error will result also if no virtual mailbox - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 148
20 = staples the number of specified sheets. 0 = off 1 = center stitch and stapling 0 = off 1 = main position 2 = alternate position 0 = off 1 = blank separator 2 = duplicated separator number representing the paper source (tray) 0 = off 1 = on 138 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 149
manner as the JOBO command (See JOBO on page 136.). Use of the JOBP command allows to use the different settings for copy count, duplex printing, stapling, etc., from those originally set for the print job. For example, it is possible to duplex-print the print job (in which duplex-printing was - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 150
save-mode, copy, barcode, barcode-position[, share, 'job-name', 'user-name', 'time']; Parameters save-mode: save mode: 0 = electronic Must be 0 job-name: job name, character string up to 80 bytes user-name: user name, character string up to 80 bytes time: time stamp, character string up - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 151
barcode scanner manual.)' and information regarding the job which was thrown away is displayed in the error log. If JOBS-JOBT pairs are nested or if they are not paired properly, the job defined between the innermost JOBS-JOBT pair will be valid. The command is invalid if any of the job name, user - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 152
mailbox specification (See JOBP on page 138.), the job in question will not be saved to any virtual mailbox and no error will be displayed. While jobs are being stacked on a virtual mailbox, a message indicating that jobs are being stacked on virtual mailboxes (when the VMB-compatible printer driver - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 153
JOBS !R! JOBS 8, 3, 3, 15, 0, 'Service', 'Repair', '01/14/02 16:30:25'; UNIT C; MZP 5, 10; BOX 6, 6; PAGE; TEXT 'ABCDE'; PAGE; TEXT 'Domestic'; PAGE; JOBT; EXIT; 143 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 154
in the cyclic manner. At execution, the JOBT command starts printing the job including stapling, job separation, job offset (if the relevant option device is installed). File The file below sorts and prints the defined job in 40 copies. The pages between JOBS and JOBT are output to virtual mailbox - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 155
of a command such as RES, FRPO and SEM which results in a reset of the printer. When JOG is issued with a job defined by JOBS and JOBT, jogging copies of the job defined between JOBS and JOBT (job name: My Trial, user name: Halle Berry, date: January 12, 2002) with the electronic sorting function - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 156
the function that starts the user program (Only in the case of "PRE") Up to 31 characters Function The LAPI command downloads the API program. As described name has already been stored, the sending data will be invalid. Data downloaded with the LAPI command will be deleted (invalid) upon the system - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 157
-number: font number (integer from 1000 to 65535). Same for all characters in the font. Must not duplicate any resident bitmap font number. code: ASCII code of the character (0 to 255) height: height of the character bitmap, in dots (integer from 0 to 3999) width: width of the character bitmap - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 158
such as the one shown below, which is defined as the '+' symbol (character code 43) of font 1000. Details and another example appear in Chapter 4 of the Technical Reference manual. The resolution is valid only on a 600/1200 dpi printer model. File !R! LDFC 1000, 43, 39, 29, 1216, 0, 1216, 608 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 159
, height, width, y-offset, x-offset, cell-width; bit-map; Parameters font-number: font number (integer from 1000 to 65535) code: ASCII code of the character code (0 to 255 for European; 0 to 65533 for Japanese) or in hexadecimal notation ($xxxx) height: height of the character bitmap, in dots - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 160
downloaded font header already defined using LDFN F. Note that each character code defined must match the font number, symbol set (1- or 2-byte code), and other information of the font header already created. The bitmap data transferred at the end of this command is transferred under Kyocera error - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 161
characters long). This string must be enclosed in either single or double quotation marks. symbol-set: symbol set: numeric value = 1-byte code symbol set (1 to 65535 [619: Shift JIS code]) J = 2-byte JIS code spacing: spacing: 0 = fixed spacing 1 = proportional spacing width: font width (in dots - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 162
codes from 32 to 127 1 = character codes from 32 to 127 and from 160 to 255 2 = character codes from 0 to 255 Function The LDFN F command creates a font header for downloading a font to the printer byte code) emulation Japanese character (2-byte code) emulation (linked using ASFN) A command error - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 163
Since there are two font headers for Japanese TrueType fonts, the printer automatically creates a font number increased by 1. name: font name: length: number of bytes sent as binary data symbol-set: font symbol set value: 1 to 65535 (619 = Shift JIS code) style: font style: 0 to 32767 stroke: - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 164
by WRED; are not counted as part of the font data length. The maximum number of fonts that can be downloaded is up to the memory available or the given range. This command is ignored if even one parameter error occurs. Although symbol-set, style, stroke and type-face may be omitted, we recommend - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 165
to 10 (Default is 0) Function The LGHT command controls lightness and darkness balance based on the specified parameters. The gamma and contrast can be set independently of each other. In gamma control mode, the color bars below represent the lightness gamma variation using hue R as an example. The - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 166
PRESCRIBE Command Reference Default contrast Contrast set to high Contrast set to low Varying the darkness contrast color spaces, all color modes and all monitor simulation modes. If ink simulation is set to other than none, this command is disabled. This mode is not held permanently in the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 167
top margin Function The MAP command moves the cursor to a position specified relative to the top and left margins, measured in the units designated by the UNIT command. The coordinates may be positive or negative. Negative coordinates move the cursor outside the margin. The MAP command is ignored in - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 168
PRESCRIBE Command Reference Printout Related Commands MRP, MZP, MRPA 158 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 169
Function The MCLR command selects the mode of color matching. Color matching mode is changed according to the various conditions of emulation, paper type, and print quality. In monochrome mode, color matching is defaulted to 0 (none). Mode 0 does not perform color matching. Mode 1 automatically - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 170
first delete the old definition with the DELM (delete macro) or DAM (delete all macros) command, or by switching power off. See the Technical Reference manual for information on the limitations about the usage of macros. The PCL5E command language, available in the mode 6 emulation, enables - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 171
EPROM based PCL macros cannot be deleted. Downloaded PCL macros, available for all FS-series printers, may be removed using the PCL reset or delete commands: &f6X or &f8X. Downloaded macros may also be sent to specific host buffers of the printer interfaces. The memory card and ROM macros - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 172
PRESCRIBE Command Reference MDAT - set MeDia type ATtribute Format MDAT [media-type[, paper-weight, fuser-mode, duplex[, density]]]; Parameters media-type 1 = Plain 2 = Transparency 3 = Preprinted 4 = Label 5 = Bond 6 = Recycled 7 = Vellum 8 = Rough 9 = Letterhead 10 = Color 11 = Prepunched 12 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 173
. If all the parameter are omitted (MDAT;), all the attributes for the all media types are reset to the default. File To set the transparency paper type to the thick paper weight and the high fuser temperature mode, disabling the duplex printing, command: !R! MDAT 2, 1, 0, 1; EXIT; Related Command - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 174
it is changed by another MID command (It is not reset by the RES command). If the printer receives an ASTK command or one of the FRPO commands specific (FRPO S0, 2;) or off (FRPO S0, 0;). Refer to the sorter's User's Manual. Note File This command is irrelevant to certain combination of photocopier - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 175
number of Quick Copy jobs size: number from 0 to 9999 in unit of megabytes number from 1 to 50 for QUICKLIMITCOUNT Function The MPSS the hard disk. Files To set the maximum capacity for the permanent jobs to 600 MB: !R! MPSS 'CODE', 'PERMLIMITSIZE', 600; EXIT; To set the maximum capacity of the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 176
MP tray is empty. When Mode is 0, this message is disabled despite the MP tray is empty and the other paper source(s) is not empty. (showing Ready, for example). It is not reset by the RES command, therefore, to change mode, the MPTE command should be used. File To configure the MP - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 177
the current cursor position Function The MRP command moves the cursor from its current position to a specified relative position, measured in the units designated by the UNIT command. The coordinates may be positive or negative. The MRP command works in the standard mode graphics only. To move to - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 178
PRESCRIBE Command Reference Printout Related Commands MAP, MZP, MRPA 168 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 179
a specified angle. The distance is measured in the units designated by the UNIT command. The MRPA command is ignored in the path mode the PMRA (in Path, Move to Relative position by Angle) command. File !R! RES; UNIT C; CMNT Numbers indicate cursor movement; SFNT 'Helvetica-Bd'; MAP 6, 12; CIR 1; - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 180
PRESCRIBE Command Reference Printout Related Commands MAP, MRP, MZP 170 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 181
installed with the printing system. It instructs the user to remove paper. By removing all the pages in the bulk tray and pressing the ON LINE key, printing commences. If the tray parameters are omitted, all trays excluding the bulk tray are used. Upon receiving the MSTK command, the printer - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 182
command to work, the automatic cassette switching mode must be set to on in the printing system. To do this, command: !R! PSRC 100; EXIT;. For details see the PSRC (set paper source) command section in this manual. To ensure that the paper having the correct size and type of media is always selected - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 183
MP tray size to A4 and the MP tray type to Labels (See the user's manual for details.) !R! RES; PSRC 100; CMNT Sets the printer to automatic casette mode; CMNT Depending on the current media type; SPSZ 8; MTYP 4; CMNT Paper size = A4, media type = label; RES; EXIT; Related Commands PSRC, SPSZ 173 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 184
Function The MZP command moves the cursor to a position specified relative to the top and left edge limits of the paper, measured in the units designated by the UNIT command. The coordinates may be positive or negative. Negative coordinates, however, move the cursor off the page, which should be - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 185
MZP Printout Related Commands MAP, MRP, MRPA 175 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 186
line along it (STRK, FILL). For a full description of path, refer to Chapter 1 of the Technical Reference manual. File !R! RES; UNIT C; NEWP; PMZP 5, 5; PDRP 1, -2, 3, 0, -1, 2, -3, 0; STRK; CMNT Stroking the path; NEWP; PMZP 10, 5; PDRP 1, -2, 3, 0, -1, 2, -3, 0; GPAT .5; FILL 1; CMNT Filling the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 187
OTRY - select paper Output TRaY Format instructs the printing system to deliver printed pages to its face-up tray; the value 3 delivers the pages to its face-down tray. The tray values of 5, 7, 11, 12, 13, 14, 21, 22, 31, 32, 41, 42, 51, 52, 61, 62, 71, and 72 are valid for certain copiers installed - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 188
delivered face-down as usual, page 1 first. !R! PAGE; EXIT; PAGE 2 PAGE 2 next, and so on, stacking in the correct order. !R! PAGE; EXIT; PAGE 3 But on printers with two paper trays this file will be delivered to the face-up tray with the pages in reverse order, page 3 on top. !R! PAGE; EXIT; 178 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 189
PAGE PAGE - start new PAGE Format PAGE; Parameter None Function The PAGE command causes a page break without resetting the printer. Subsequent data will be printed on a new page with no changes made to page formatting parameters such as spacing, margins, font selection. If there is - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 190
specify the PANTONE uncoated color by number or name. (See http://www.pantone.com for details on Pantone Colors.) The following should be noted when specifying a color by its PANTONE 45 colors can be specified by name (see list below). These colors must be spelled as shown, although the letters may be - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 191
11 Process Black Rhodamine Red Yellow Black 4 Warm Gray 4 Warm Gray 8 Cool Gray 4 Cool Gray 8 The PANT command may not work with certain printer models and versions. Set the print quality to Quick mode when this command is used with model FS-5800C. PANTONE colors cannot be used by the PANT command - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 192
direction only. After the path is stroked, the cursor remains at the ending angle of the arc. File !R! RES; UNIT C; NEWP; SPD .1; PMZP 5.0, 10.0; PARC 6.5, 12.5, 1.5, 180, 270; STRK; NEWP; CMNT This program draws a circle; PMRA 6.5, 18, 1.5, 0; CMNT Moves cursor 1.5 cm by 0 degree; PARC 6.5, 18 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 193
PARC Printout 183 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 194
1 through 60 if a resident pattern is selected. A full list of the printer's resident patterns appear on the following page. Pattern numbers 100 through patterns are defined, the printer selects the No. 1 (solid black) resident pattern. Variable resolution support is valid for 600 dpi and 1200 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 195
PAT Resident Fill Patterns (300 dpi) 185 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 196
PRESCRIBE Command Reference PCRP - in Path, Curve to Relative Position Format PCRP x1, y1, x2, y2, x3, y3; Parameters x1, y1: coordinates of the first control point as measured from the current cursor position x2, y2: coordinates of the second control point as measured from the current - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 197
File !R! RES; UNIT C; NEWP; SPD .1; PMZP 3, 3; PCRP 4, 2, 5, 1.5, 6, 1.8; STRK; PAGE; EXIT; Printout Current positon (5, 1.5) (4, 2) (6, 1.8) File !R! RES; UNIT C; NEWP; SPD .1; PMZP 3, 3; PCRP 5.5, 1.5, 1.5, 5.5, 7, 7; STRK; PAGE; EXIT; Printout Current positon (5.5, 1.5) PCRP (1.5, 5.5) - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 198
x2, y2: coordinates of second control point as measured from the left and top edge limits of paper x3, y3: coordinates of end point as measured from the left and top edge limits of paper Function The PCZP command adds a Bézier curve segment to the path, starting from the current cursor position - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 199
File !R! RES; UNIT C; PMZP 3, 6; PCZP 11, 3, 2, 2, 9, 6; STRK; PAGE; EXIT; Printout (2, 2) PCZP (11, 3) (9, 6) Current position (3, 6) 189 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 200
PRESCRIBE Command Reference PDIR - set Print DIRection Format PDIR angle; Parameter angle: angle in degrees; in 90° increments in a counterclockwise direction 0 = portrait 90 = landscape 180 = reverse portrait 270 = reverse landscape Function The PDIR command rotates the coordinates of the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 201
(PDIR 90;) PDIR Reverse Landscape (PDIR 270;) Reverse Portrait (PDIR 180;) File !R! RES; UNIT P; SFNT 'Helvetica', 8; UNIT C; MZP 10, 12; SPD .144; CIR .075; PDIR 270; TEXT ' ENDLESS VARIETY AND VERSATILITY'; PDIR 180; TEXT ' ENDLESS VARIETY AND VERSATILITY'; PDIR 90; TEXT ' ENDLESS VARIETY - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 202
PRESCRIBE Command Reference Printout 192 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 203
by the SPD command. Multiple pairs of coordinates may be specified. The printer then draws a connected series of line segments, proceeding from one point to the next. For example, PDRP 1, 2, 3, 4; is equivalent to PDRP 1, 2; PDRP 3, 4;. File !R! UNIT C; SPD .3; CMNT Cube; NEWP; PMZP 5, 15; PDRP - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 204
PRESCRIBE Command Reference Printout Related Command PDZP 194 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 205
the current cursor position to a position specified relative to the top and left edge limits of the current page, measured in the units designated by the UNIT command. The cursor moves to the specified coordinates. The coordinates may be positive or negative. Negative coordinates may draw the line - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 206
PRESCRIBE Command Reference Printout Related Command PDRP 196 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 207
FILL is required. A complete ellipse path will be defined if the parameters in brackets are omitted. Executing this command will close current sub-paths. An error will result and the command has no effect if the bounding box is specified as a straight line or a point. 197 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 208
Command Reference Current cursor position (x-end, y-end) (x-start, y-start) Bounding box (x-diagonal, y-diagonal) N : C : P : File !R! RES; UNIT C; MZP 0, 0; BOX 2, 3; NEWP; PMZP 0, 0; PELP 2, 3, 2, 0, 0, 0, N; STRK; MZP 5, 5; BOX 2, -3; NEWP; PMZP 5, 5; PELP 2, -3, 2, 0, 0, 0, N; STRK; MZP 10 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 209
exceed 9999. The total length of the command must not exceed 255 characters. The printer automatically converts the slice sizes to angles totaling 360 degrees. It draws the first thickness is designated by the SPD command. File !R! RES; UNIT C; MZP 10, 10; PIE 3, 0, 10, 20, 30, 40; PAGE; EXIT; 199 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 210
PRESCRIBE Command Reference Printout 200 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 211
coordinate: coordinates as measured from the left and top edge limits of the page distance: distance specified in increments governed by the unit value. angle: angle in degrees, measured counterclockwise from the positive x axis Function The PMRA command moves the cursor to a position in a path - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 212
PRESCRIBE Command Reference File !R! RES; UNIT C; SPD 0.2; NEWP; PMRA 10, 19, 5, 45; PARC 10, 19, 5, 45, 135; STRK; PAGE; EXIT; Printout 202 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 213
a specified relative position in a path construction, measured in the unit value designated by the UNIT command. The coordinates may be positive or negative. File !R! RES; UNIT C; NEWP; PMZP 5, 5; PDRP 5, 0, 0, 5, -5, 0, 0, -5; GPAT .2; FILL 1; PMRP 4, 4; PDRP 5, 0, 0, 5, -5, 0, 0, -5; GPAT .8; FILL - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 214
PRESCRIBE Command Reference Printout Related Command PMZP 204 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 215
positive or negative. Negative coordinates move the cursor off the current page. File !R! RES; UNIT C; STM 2; SLM 2; SFNT "Helvetica-Nr"; NEWP; PMZP 0, 0; SPD .2; PMZP 0, 4; FONT 13; TEXT '< = = = Paper edge limits'; PMZP 0, 0; PARC 0, 0, .1, 0, 360; PMRP 0, .333; TEXT ' PMZP 0, 0;'; PMZP 4, 0; PARC - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 216
PRESCRIBE Command Reference Printout Related Command PMRP 206 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 217
PNCH PNCH - PuNCH Format PNCH[ mode]; Parameter mode: number of punched holes: 1 = 2 (Europe) or 3 (U.S.) 2 = 4 (Europe) or 2 (U.S.) 51 = 2 (Europe) or 3 (U.S.), left 52 = 4 (Europe) or 2 (U.S.), left 61 = 2 (Europe) or 3 (U.S.), right 62 = 4 (Europe) or 2 (U.S.), right 71 = 2 (Europe) or 3 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 218
51, 52, 61, 62, 71, and 72 are valid for some copier models only. These parameters allow to position the holes in either of unit.With a finisher with the standard punch unit only (e.g. the DF-75), the number of punched holes is uniquely determined according to the country of destination and paper - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 219
PRBX PRBX - in Path, draw Round BoX Format PRBX width, height, radius; Parameters width: width of round box height: height of round box radius: radius of round box corners Function The PRBX command adds a round box path to the current path. This command close the sub-paths but does not stroke - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 220
PRESCRIBE Command Reference File !R! RES; UNIT C; SPD 0.125; NEWP; PMZP 1, 1; PRBX 11.7, 1.7, 0.5; STRK; MZP 1.5, 2.15; SFNT "Helvetica-Bd", 24; TEXT "CAUTION: HOT SURFACE!"; PAT 5; NEWP; PMZP 1, 4; PRBX 5, 2.4, 0.3; FILL; MZP 1.4, 4.7; SFNT "Helvetica- - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 221
designated by the UNIT command; the starting and ending angles are measured counterclockwise from the positive x axis. For example, the following example draws an arc extending over the center of the arc: PRRC 1, 1, 0, 180; Whereas, the following command, having the reversed starting and ending - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 222
Command Reference PRRC 1, 1, 180, 0; Negative values are acceptable for angle. For example, an angle of 315 degrees is the same as -45 degrees. File !R! RES; SPD 0.05; MZP 4.5, 5; NEWP; PRRC -1, 0, 1, 90, 270; PRRC 1, -2, 1, 0, 180; PRRC 2, 1, 1, -90, 90; PRRC -1, 2, 1, 180, 0; STRK; PAGE; EXIT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 223
be placed at the beginning of a file or program, or at the top of a new page. The current paper source will remain selected if the specified cassette is not installed. File !R! RES; UNIT C; SFNT "Helvetica-Nr", 24; PSRC 1; TEXT "This page is fed from the default cassette."; PAGE; PSRC 0; TEXT "This - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 224
(3, 4), a different result is obtained depending on each pixel placement mode. Grid intersection is default to HP PCL; and grid centered mode is used by Microsoft Windows. This command is ignored when used with DAP, DRP, DRPA, DZP, BOX, BLK, CIR, ARC, or PIE. This command has no effect for text or - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 225
command recognition character to its FRPO-set value. Permanent changes can be made with the FRPO command described in Chapter 6 of the Technical Reference manual. If !R! is used by mistake when the printer is already in the PRESCRIBE mode, the printer ignores the mistaken !R! and whatever follows - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 226
PRESCRIBE Command Reference Printout Related Commands EXIT, SCRC 216 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 227
Function The RCLT command instructs the printing system to stack the sets on the tray in alternating orientations. The RCLT command require a hard disk installed in the printing system or a RAM disk. The RCLT command is available when printing using A4, B5 and letter size paper. During printing, the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 228
PRESCRIBE Command Reference RDMP - Received-data DuMP Format RDMP; Parameter None Function The RDMP command causes all subsequent data to be printed in hexadecimal form (two hexadecimal digits per character) until an ENDD (END Dump) command is received, or until the printing system runs out of data - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 229
Sample RDMP 219 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 230
this value in parenthesis. In HP-7475A emulation, the RES command resets the printer environment in the same manner as the KC-GL DF instruction. Refer to section HP 7550A Emulation [KC-GL] (Mode 8) of the Technical Reference manual. The RES command does not: • delete permanent macros or permanent - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 231
reset Reference manual. SETF Country code 0 (U6)† ← ← INTL Symbol set Roman -8 (U6/7) See Emulation of US ASCII (U7)† CSET, INTL the Technical Reference manual P3) ← - a These values can be set as permanent using the prin system's operator panel - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 232
on paper. This does not affect the current unit of measure, but the system's memory will be reconfigured, causing PCL resources (fonts, macros, patterns, and symbol sets) which have been downloaded into RAM to be purged. The printing system's resolution setting enabled by this command is reset to - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 233
Color balance decreased Default color balance (B) Color balance increased Color balance decreased Varying color balance allows the output image results to vary. Issuing this command resets hue, saturation, and luminosity control values to their default settings. 223 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 234
This command is enabled for all color spaces, all color modes and all monitor simulation modes. If ink simulation is set to other than none, this command is disabled. The RES command resets saturation to its default state. This mode is not held in the printing system. For this reason, color balance - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 235
paper feed direction, in current unit command is received. The offset values set using this command are valid even cleared to zero only by a software reset (E). In other words, the offset is error will result and the command has no effect if a command format other than the above is used. An error - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 236
PRESCRIBE Command Reference RPCS - Return to Previous Code Set Format RPCS; Parameter None Function The RPCS command resumes use of a code set saved by a previous SCCS (save current code set) command. The RPCS commands return to the code sets in reverse order in which they were nested. File See SCCS - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 237
commands return to the fonts in the reverse order in which they were saved. SCF and RPF are particularly useful in macros. File !R! RES; UNIT P; MCRO SMALLPRINT; SCF; FSET 10V; TEXT %1, E; RPF; ENDM; SFNT 'Helvetica', 12; SLS 14; EXIT; Computer literature is littered with acronyms such as !R! CALL - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 238
is shown below. The RPG command does not affect other printing system parameters such as page orientation, unit of measurement, etc. (See RES on page 220.) File !R! RES; UNIT C; NEWP; PMZP 4, 2; PARC 3, 3, 1, 90, 270; PARC 5, 3, 1, 270, 90; CLSP; SCG; CMNT Saves the graphics state; STRK; CMNT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 239
RPG Printout Related Command SCG 229 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 240
P; SFNT 'Helvetica-BdOb', 16; UNIT C; MAP 8, 8; CIR .2; MRP -.1, .1; CMNT Save this position seven times; SCP; SCP; SCP; SCP; SCP; SCP; SCP; MRPA 2, 0; TEXT 'N'; RPP; MRPA 2, 45; TEXT 'NE'; RPP; MRPA 2, 90; TEXT 'E'; RPP; MRPA 2, 135; TEXT 'SE'; RPP; MRPA 2, 180; TEXT 'S'; RPP; MRPA 2, 225; TEXT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 241
RPP Printout Related Command SCP 231 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 242
PRESCRIBE Command Reference RPPL - Return to Previous PaLette COLOR Format RPPL; Parameter None Function The RPPL command restores the color palette most recently saved by a SCPL (save current palette) command. A color palette restored using the RPPL command immediately becomes active. If the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 243
RPU RPU - Return to Previous Unit Format RPU; Parameter None Function The RPU command brings the unit of measurement (inches, centimeters, points, or dots; as specified by the UNIT command) back to the unit saved by the SCU (save current unit) command. File/Printout See SCU on page 283. Related - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 244
PRESCRIBE Command Reference RTTX - RoTate TeXt Format RTTX angle, 'string'[, U-option]; Parameters angle: angle of rotation in degrees string: character string U-option: Underline text Function Taking the normal output angle for text as zero, the RTTX command rotates a character string - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 245
RTTX Printout 235 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 246
option is specified, the string is underlined. The underline thickness and location can be set by the SULP command. The RTXT command can be used to position a line be longer than 255 characters. Carriage-return and linefeed codes in the string are ignored. The RTXT command can be used both in - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 247
File !R! RES; UNIT P; SFNT 'TimesNewRoman'; UNIT I; MCRO PF; MRP .15, 0; BOX .1, -.1; MRP .5, 0; BOX .1, -.1; MRP -.65, 0; ENDM; MAP 3, 3; TEXT 'Pass Fail', L, U; CALL PF; RTXT 'Unit test', L; CALL PF; RTXT 'Integration test', L; PAGE; EXIT; Printout RTXT 237 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 248
raster data by the amount of bytes represented by the length parameter. The STR (SeT dot Resolution) command sets the dot resolution for raster graphics which starts at the current cursor position. The SRO (Set Raster Options) command specifies the orientation of the raster image in either physical - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 249
RVCL command is the color version of the RVCD (ReceiVe Compressed raster Data) command. It transfers the color raster data. Color specification must be made to each pixel. An 8 bps color specification is used for the color data for each pixel. Also, this command is only valid for an RGB color space - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 250
+0+0+0+0+0+0 = 192 In the printing system command language, the segments are being treated as bytes of data in which the black dots are 1s and the white dots are 0s. The raster data values are the decimal values of the bytes. Each line of raster data starts with a positive integer (1 to 511 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 251
which follows. The subsequent data can be obtained by following the same procedure as explained in Defining Fill Patterns in Chapter 2 of the Technical Reference manual. 241 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 252
= Macro data 112 = File data 128 = API data (downloadable program) partition-name: Name of partition from which data is deleted or double quotation marks. A partition list is not automatically printed when deleting command). ( See page 244.) A command error results and the command has no effect if - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 253
disk is physically formatted when it is specified. This command has no effect if the media has been write-protected using KPDL or PJL. A command error results and the command has no effect if parameters other than the above are used. This command causes a page break and prints a format information - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 254
disk. With the automatic printing of partition lists enabled (RWER I, E;), the printing system prints partition lists whenever data are written to external media. The setting made with this command returns to default when the power is turned off. A command error results and the command has no effect - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 255
for all external media can be printed by omitting parameter medium. Disk capacity, font cache capacity and data type are listed, with login file names for file data output in separate columns. A command error results and the command has no effect if parameters other than the above are used. 245 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 256
-type, 'partition-name'; Parameters medium: 0 = hard disk or RAM disk A = memory card E = EPROM data-type: 2 = Printable data 128 = API data (downloadable program) partition-name: Name of partition from which data is read, a maximum of 15 printable ASCII characters Function The RWER R command - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 257
value, style, weight, type-face];binary-data WRED; Parameters medium: drive specification: 0 = hard disk or RAM disk A = memory card font-type: of bytes sent as binary data) value: font symbol set value (1 to 65535, 619: Shift JIS code) style: font style (0 to 32767) weight: stroke weight - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 258
allows outline fonts (in TrueType format) to be downloaded to the printing system and to be stored five bytes represented by WRED; are not counted as part of the font data length. Since value, style, fonts and (F) for fixed pitch fonts. A command error will result and the command has no effect if any - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 259
. This terminator is used when storing binary data to external media. See the RWER S command page (page 247) for example. WRED is set as the default terminator if parameter terminator is omitted. A command error results and the command has no effect if parameters other than the above are used. 249 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 260
Printable data 16 = Macro data 112 = File data 128 = API data (downloadable program) partition-name: Name of partition to which data is written, in a maximum overwriting the original file. A partition list will be printed as a warning when this happens. A command error results and the command has no - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 261
RWER W 1. Verify the printing system's message display indicates Ready. 2. Enter the following at the DOS prompt: C:\>ECHO !R! RWER W, A, 2, 'DATA123'; >PRN The message display will change from Ready to Processing, and then to Waiting. The printing system is now ready to receive data, so send the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 262
PRESCRIBE Command Reference RWRF D - [Read/Write Resource File] Delete data on external device Format RWRF D, medium, data-type, "file-name"; Parameters medium: 0 = hard disk A = memory card data-type: "API" API program "FNT" Font data "MCR" Macro data "PRN" Printable data file-name: ASCII text - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 263
RWRF F RWRF F - [Read/Write Resource File] Format external device Format RWRF F, medium; Parameters medium: 0 = hard disk A = memory card Function The RWRF F command physically and logically formats an external device such as the hard disk. This command has no effect if the target device has - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 264
RWRF L[, 'medium']; Parameters medium: 0 = hard disk A = memory card Prints a resource file list for all devices if omitted. Function The RWRF L command prints a resource file list registered in an external device. Example: Print a resource file list in the hard disk. !R! RWRF L , 0; EXIT; 254 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 265
card data-type: "API" API program "FNT" Font data "MCR" Macro data file-name: ASCII text string up to 15 bytes. Function The RWRF P command sets the specified file as a hidden one. The specified file, which is hidden, cannot be accessed from any PC. This command causes a page break. Example - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 266
any external media. The data must be a printable data. When the file name is coexistent in both the hard disk and memory card that are installed in the printing system, the printing system will read the memory card first, then the hard disk. The partition name may be a maximum of 15 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 267
Terminate string Format RWRF T[, 'terminator']; Parameters terminator: ASCII text string up to 4 bytes Set to default "WRED" if omitted. Function The RWRF T command changes a terminator (default: WRED). The terminator that was changed with this command is also available for - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 268
API-program-start-function-name: ASCII text string up to 31 bytes Cannot be omitted. file-name: ASCII text string up to 15 bytes Automatically set by the system if omitted. Function The RWRF W command writes data to an external device such as the hard disk. The number of writable files - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 269
medium, "FNT", font-type, "file-name", "font-name", font-datalength, symbol-set-value, font-style, stroke-weight, typeface; Parameters medium: 0 = hard disk A of bytes in font data to be downloaded symbol-set-value: 1 to 65535 (619 = Shift JIS code) font-style: 0 to 32767 stroke-weight: -127 to - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 270
appends (1), (2), (3)...(9). You can omit the parameters ranging from symbol-set-value to typeface; however, you should not omit those font written must match the specified one. Failure to do so will result in an error, and disables you to write data. Specify WRED; command following . - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 271
(0 to 32767) macro-name for prescribe macro (ASCII text string up to 4 bytes) file-name file-name: ASCII text string up to 15 bytes Automatically set by the system if omitted. Function The RWRF W command writes data to an external device such as the hard disk. The number of writable files - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 272
data) Format RWRF W, medium, "PRN", "file name"; Parameters medium: 0 = hard disk A = memory card file-name: ASCII text string up to 15 bytes Automatically set by the system if omitted. Function The RWRF W command writes data to an external device such as the hard disk. The number of writable - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 273
need to control with care. This command is enabled for all color spaces, all color modes and all monitor simulation modes. If ink simulation is set to other than None, this command is disabled. This mode is not held in the printing system. For this reason, saturation is - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 274
Bottom Margin Format SBM length; Parameter length: distance from top of paper to bottom margin Function The SBM command sets the bottom margin, as measured from the top edge limit of the paper in the units designated by the UNIT command. If an attempt is made to print below the bottom margin - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 275
SBM Printout 265 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 276
PRESCRIBE Command Reference SCAP - Set line CAP Format SCAP mode; Parameter mode: line cap semicircular caps with diameters identical to the line width. Square caps (default) Butt caps Round caps File !R! UNIT C; SPD .5; NEWP; CMNT Round-capped on every end; SCAP 3; PMZP 6, 6; SCP; SCP; PDRP - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 277
SCAP Printout 267 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 278
SCCS; Parameter None Function The SCCS command instructs the printing system to remember the code set of the current font. This command may be used in conjunction with a SCF (save current font) command to prevent the font from losing the current code set after a command operation has been made - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 279
SCCS Printout Related Commands RPCS, RPF, SCF 269 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 280
to eight font numbers can be saved in the printing system's memory by SCF commands (using a separate SCF command for each). The SCF command only instructs the printing system to remember the font. It does not move actual fonts in or out of memory. File !R! RES; SLM 1; STM 2; SFNT 'TimesNewRoman - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 281
SCF Printout Related Command RPF 271 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 282
path. The printing system holds as much graphics state information as the user memory area can accommodate; however, graphics state information larger than the memory area can cause a memory error. File !R! RES; UNIT C; NEWP; PMZP 5, 5; SFNT 'Helvetica-Bd', 72; CPTH 'Mary'; SCG; STRK; RPG; GPAT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 283
SCG Printout Related Commands FILL, RPG 273 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 284
affect the following objects: • Color patterns • Color raster images Once a color is specified by SCOL, the active color does not change until the next color specification is made even if a palette is created, changed or deleted. File and Printout See ACLI on page 12. Related Commands ACLI 274 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 285
SCP SCP - Save Current Position Format SCP; Parameter None Function The SCP command instructs the printing system to remember the current cursor position, so that it can be retrieved later using the RPP (return to previous position) command. Up - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 286
Characters Per Inch Format SCPI number; Parameter number: number of characters per inch Function The SCPI command sets the number of characters per inch (even if the UNIT command designates a non-inch unit). When a proportionally-spaced font is used and the font mode (FTMD) is 0 to 3 or 8 to 11 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 287
SCPI Printout Related Command SCS 277 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 288
not change the active palette. RPPL commands return to the saved palettes in the reverse order in which they were saved. File !R! RES; SEM 6; UNIT C; SFNT 'Incised901SWC-Black', 20; SPAL 100; CID 0, 1; ACLI 1, 128, 64, 64; SCPL; SPAL 101; CID 0, 1; ACLI 1, 128, 0, 128; SCPL; MZP 1, 1; RPPL; SCOL - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 289
Set Command Recognition Character Format SCRC character; Parameter character: new command recognition character, any character from ASCII code 33 (!) to ASCII code BLK 1.6, 1.6; BOX 1.6, 1.6, E; CMNT Now list the above commands; SCRC L; EXIT; !R! RES; UNIT C; GPAT .7; BLK 1, 1; BOX 1, 1, - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 290
PRESCRIBE Command Reference Printout 280 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 291
be specified to obtain the innate spacing of each character. A nonzero specification results in unnatural spacing of proportional fonts. SCS 0 does not change the can be set using either the SCS or the SCPI command. File !R! RES; SLM 1; STM 2; EXIT; This line has the default spacing. !R! UNIT C; SCS - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 292
Command Reference SCSZ - Set Custom paper SiZe Format SCSZ width, height, unit; Parameters width: width of custom paper size height: height of custom paper size unit: M = millimeters I = inches Function The SCSZ command sets the paper size when the user-defined size paper is used in the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 293
instructs the printing system to save the current unit of measurement. Saving the current unit can prove useful when a macro containing a UNIT command changes the unit of measurement. The saved unit 9; UNIT C; SCU; MZP 1.5, 1.5; TEXT "THE DAYS ON THE ISLAND: PART I", U; MCRO TITLE; FSET 24V; UNIT I; - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 294
PRESCRIBE Command Reference Printout Related commands SCF, SCP, UNIT 284 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 295
of alternating black and white segments for stroking the line segment in the path, using the unit value designated by the UNIT command. For example, SDP with a dash, the last space value may be omitted. The user-defined dash patterns are valid until another SDP command changes the current definition or - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 296
PRESCRIBE Command Reference File !R! RES; UNIT P; SDP 11, 2, 2, 5, 5; NEWP; UNIT C; SPD .2; PMRA 10, 10, 3, 0; DPAT 11; PARC 10, 10, 3, 0, 360; STRK; PAGE; EXIT; Printout Related Command DPAT 286 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 297
issued. The SEM command also resets the margins and various other parameters. It should therefore be placed at the beginning of a program or file. The SEM command does not change the power-up emulation mode. When power is switched off, the printing system loses the mode set by the SEM command. Upon - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 298
when given a temporary font number in advance. See the SFNT (set font) command page. In some emulation modes, default assignments are can be embedded for some word processing software. See Emulation of the Technical Reference manual. File !R! RES; SFNT 'Helvetica', 10, 2000; SFNT 'Helvetica-BdOb', - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 299
SETF Printout 289 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 300
Attributes Format SFA hmi, vmi, F/P[, rotation, symbol-set, height, U/I, weight, typeface][, font-type]; Executable normal 1 = face-down 2 = upside down 3 = face-up (used in landscape mode) symbol-set: symbol set (number from 0 to 65535): 4 = ISO 60 Norway 5 = Roman Extension 9 = ISO 15 Italian - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 301
from -7 (light) to +7 (bold) type-face: 0 = Line Printer 1 = Pica 2 = Elite 3 = Courier 4 = Swiss 721 codes. The printing system must be set to the HP transparency mode. See Emulation of the Technical Reference manual not reset by the RES (reset) the unit value designated by the UNIT command - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 302
describe downloaded fonts UNIT C; SLM 2; STM 4; FONT 1; SFA .25, 1, F; FONT 2; SFA .15, .5, P; FONT 1; EXIT; At these settings, in font mode 15, font 1 is double spaced (1 cm), !R! FONT 2; EXIT,E; while font 2 is single spaced (0.5 cm) with 1.5 mm spaces between words. !R! FONT 1; EXIT,E; The printer - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 303
SFA Printout 293 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 304
matches the type-face parameters. It enables the user to size its height, assign a font number font table in Section 4.2. of the Technical Reference manual. Specify the full name exactly as it appears font, using the unit of points regardless of the current unit setting. The SFNT command is ignored - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 305
number matches one already assigned to another font, the printing system ignores the SFNT command. symbol-set uses HP PCL matching code to change the font's symbol set. Unsupported symbol set values, if specified, are ignored. compression squeezes or expands characters in the horizontal direction - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 306
PRESCRIBE Command Reference This is 10-point Helvetica-Nr, with Roman-8 symbol set, compression is 2, and shear is .3. You can later recall this font by the FONT 3000; command. !R! PAGE; EXIT; Printout 296 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 307
: number from 1 to 8 corresponding to FRPO G1 to G8 parameter color: 0 = Black 1 = Red 2 = Green 3 = Yellow 4 = Blue 5 = Magenta 6 = Cyan 7 = White Function The SGPC command sets the color of a pen 1 through 8 for use with KCGL to a specified color. The specified value is permanently saved in the - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 308
of one character to the center of the next; in a proportionally spaced font, the width of the space character Function The SHMI command sets the HMI. The parameter is measured in the unit value specfied by the UNIT command. File !R! RES; SLM 1; STM 2; EXIT; This line has the default spacing - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 309
image - - Transparent Opaque Transparent Opaque Function The SIMG command sets the mode for controlling the transparency and opaqueness of an image the source image's transparency only. The default operation mode is 1. The white pixels of the source image do not overlay on the destination. For - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 310
is enclosed within a square comes overlaid onto the destination. The pattern image fills only the area on the destination which is covered by white pixels. Note that the letter A is patterned only with its opposing quarters. operation mode = 6: Both source and pattern images are opaque, the entire - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 311
File !R! RES; UNIT C; NEWP; PMZP 5, 5; PDRP 2.5, 0, 0, 2.5, -5, 0, 0, 2.5, 2.5, 0; PAT 1; SIMG 4; FILL 1; MRP -1, 3.5; PAT 18; FSET 4158T3B0S1P108V; TEXT "A"; FILL 1; PAGE; EXIT; Printout SIMG 301 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 312
SCOL command for each palette are as follows: palette 1 (single plane) 3 (3-plane) SCOL command parameter 0 1 0 1 2 3 4 5 6 7 Color White Black Black Red Green Yellow Blue Magenta Cyan White Color assignments (using the ACLI command) cannot be made to the pallette created using the SIMP command - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 313
File !R! RES; UNIT C; SIMP 3; MCRO SIMP; NEWP; SCOL %2; PDRP 2, 0, 0, 2, -2, 0, 0, -2; FILL 1; PMRP .5, .5; ENDM; CALL SIMP,0,0; CALL SIMP,0,1; CALL SIMP,0,2; CALL SIMP,0,3; CALL SIMP,0,4; CALL SIMP,0,5; CALL SIMP,0,6; CALL SIMP,0,7; PAGE; EXIT; Printout SIMP 303 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 314
Set Image Refinement level Format SIR level; Parameter level: 0 = Off 2 = On (Medium) Function The SIR command accesses different levels of Kyocera SIR command. The default value is On. Refer to the User's Manual for details about how to obtain the optimum level of the image refinement. File !R! - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 315
SLJN SLJN - Set Line JoiN Format SLJN mode; Parameter mode: line join mode: 1 = Beveled join 2 = Mitered join 3 = Round join 4 = Notched join Function The SLJN command determines how two - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 316
PRESCRIBE Command Reference File !R! RES; UNIT C; NEWP; SPD .5; SCAP 3; CMNT Round-capped at the upper-left corner; SLJN 3; CMNT Round-joined at other corners; PMZP 5, 16.5; PDRP 3, 0, 0, 3, -3, 0, 0, -3; STRK; NEWP; SCAP 1; CMNT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 317
Margin Format SLM distance; Parameter distance: size of left margin Function The SLM command sets the left margin, as measured from the left edge limit of the paper in the unit value designated by the UNIT command. If the margin is moved to the right of the current cursor position, the cursor - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 318
PRESCRIBE Command Reference Printout 308 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 319
Lines Per Inch Format SLPI number; Parameter number: Number of lines per inch Function The SLPI command sets the number of lines per inch (even if the UNIT command designates a non-inch unit). File !R! RES; STM 2; SFNT "Helvetica"; EXIT; These lines have the default spacing of six lines per inch - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 320
exact number of lines, so no excess is carried over to the next page. A bottom margin setting in a document file should be placed at the beginning of the file or at a page break. File !R! RES; UNIT C; SFNT "TimesNewRoman"; STM 1; SLS 1; SLPP 10; EXIT, E; Top margin at 1 cm, with 10 lines per page - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 321
SLPP Printout 311 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 322
is measured in the unit value designated by the UNIT command. The line spacing can be set by either the SLS or the SLPI (set lines per inch) command. SLPI sets the number of lines per inch. SLS sets the number of inches (or other units) per line. File !R! RES; UNIT C; STM 5; SFNT "TimesNewRoman - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 323
W = line width L = miter length W L Function The miter limit value set by the SMLT command is the maximum ratio of the miter length through a join join automatically switches to the beveled join. This switching prevents the problem of a spike extending beyond the intersection of the path because - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 324
PRESCRIBE Command Reference File !R! RES; UNIT C; NEWP; PMZP 5, 15; SPD .5; SLJN 2; CMNT Mitered join; PDRP 1.5, -2, 1.5, 2, 1.5, -2, 1.5, 2, 1.5, -2, 1.5, 2; SMLT 10; CMNT Miter limit is 10; STRK; NEWP; PMZP 5, 19; SPD .5; SLJN 2; CMNT Mitered join; - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 325
SMNT SMNT - Set MoNiTor simulation COLOR Format SMNT monitor-type [,temperature, red-x, red-y, green-x, green-y, blue-x, blue-y, only when monitor-name value is 7 (custom). Resetting the printing system or switching emulation modes resets all custom parameters to the default states. The - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 326
to some color printing system models. At the time of release of this manual, the command is irrelevant to model FS-5800C; and monitor-name values of 0 and 2 are valid for model FS-8000C. Resetting the printing system and switching emulation mode reset all parameters to the default states. 316 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 327
SPAL is deleted when a new palette is created by the CID command. The active palette number does not change. All palettes are deleted by the reset command, leaving only the default palette. File and Printout See ACLI on page 12. 317 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 328
Format SPD diameter; Parameter diameter: line thickness Function The SPD command sets the thickness of the line used in the graphics commands (DRP, PDRP, etc.). The thickness is specified in the unit value designated by the UNIT command. The maximum thickness is 4200 dots (14 inches or 35 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 329
SPD File !R! RES; UNIT C; STM 2; SLM 2; SLS .6; SFNT "Helvetica-Nr"; SPD 0.01; DRP 5, 0; TEXT ' 0.01 cm', N; SPD 0.02; DRP 5, 0; TEXT ' 0.02 cm', N; SPD 0.05; DRP 5, 0; TEXT ' 0.05 cm', N; SPD 0.1; - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 330
in a document file should be placed at the beginning of the file or at a page break. The SBM (Set Bottom Margin) and SLPP (Set Lines Per Page) commands also set the bottom margin. File !R! RES; UNIT C; SFNT "TimesNewRoman"; STM 1; SLS 1; SPL 10; EXIT, E; Top margin at 1 cm, with 10 cm page length - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 331
SPL Printout 321 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 332
described above, it sets them to the edge limits. For example, if you set a top portrait margin greater than the paper width, then switch to landscape orientation, the printing system resets the top margin to in each orientation are not identical. See the Technical Reference manual for details. 322 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 333
SPO File !R! RES; SFNT 'TimesNewRoman-It', 10; CMNT This file is for an A4 cassette.; SPSZ 8; PAT 16, 300; UNIT C; MZP 4, 24; BOX 6, -6; MZP 7, 24; BOX 3, -3; BLK 3, -3; MZP 4, 24; TEXT, L; TEXT 'Portrait orientation'; SPO L; MZP 12, 10; BOX 6, -6; MZP 15, 10; BOX 3, -3; BLK 3, -3; MZP 12, - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 334
PRESCRIBE Command Reference SPSZ - Set Paper SiZe Format SPSZ size-code [, ratio]; Parameters size-code: 0 = Same as the size of the paper cassette 1 = Monarch (3-7/8 × 7-1/2 inches)1 2 = Business (4-1/8 × 9-1/2 inches)2 3 = International DL (11 × 22 cm)† 4 = International C5 (16.2 × 22.9 cm)† - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 335
0 at power-up and after a reset. Size codes 10 through 12, 19, and 30 are supported only by the printing system model that handles the A3 size paper. Support for other paper sizes and reduction ratios vary depending on models. For details, see the user's manual supplied with the printing system. If - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 336
the IBM and Epson emulation modes and discarded in the other emulations. The SRM (Set Right Margin) command also sets the right margin, but it measures from the left edge limit of the paper. File !R! RES; UNIT C; SLM 1; CMNT Emulation mode is 1 (IBM); SFNT "Univers-MdCd", 18; SLPI 4; SPW 10; EXIT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 337
SPW Printout Related Command SRM 327 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 338
Margin Format SRM width; Parameter width: size of right margin Function The SRM command sets the right margin, as measured from the left edge limit of the paper in the unit value designated by the UNIT command. If an attempt is made to print beyond the right margin, the characters are printed - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 339
SRM Printout Related Command SPW 329 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 340
PRESCRIBE Command Reference SRO - Set Raster Options Format SRO presentation-mode [, width, height]; Parameters of the area. These options are measured in the dot unit regardless of the current designation of the UNIT command. Raster data extending beyond the border along the width - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 341
SRO presentation-mode = 0 The width and height of the raster area are defined based on the physical page regardless of the current page orientation. The current page orientation affects the position of the current point, however. Current point Width Height Current point Width Height Portrait ( - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 342
PRESCRIBE Command Reference SROP - Set Raster OPeration Format SROP value; Parameter value: logical operations (ROP3). Logical operation value is eset to the default of 252 by the RES command. An error results and this command has no effect if the ROP3 value is outside the range 0 to 255. - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 343
CALL DBOX,2; CALL DBOX,3; RES; EXIT; Printout SROP 333 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 344
installed to the printing system. It instructs the printing system to deliver printed pages in the sorter mode. Each specified tray receives a complete set bulk output tray. This command is irrelevant to certain combination of photocopier models and option finisher models. Note File !R! RES; SSTK - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 345
of the DF-610 subtray Function The STAK command instructs the printing system to deliver pages to the corresponding copiers installed with the applicable option device. The STAK command should be placed at the top of a file or program. File !R! STAK 2; EXIT; PAGE 1 On printers with only one paper - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 346
Format STAT [mode]; Parameter mode: 0 = prints a user status page (default) 1 = prints a service person status page Function The STAT command instructs the printing system to print a page of status information, starting on a new page. The status page lists the software version and release date - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 347
STAT Sample Status Page User status page Service status page 337 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 348
Top Margin Format STM distance; Parameter distance: size of top margin Function The STM command sets the top margin, in the unit value designated by the UNIT command. A top margin setting in a document file should be placed at the beginning of the file or at a page break. If the top margin is - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 349
STM Printout 339 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 350
PRESCRIBE Command Reference STPC - set STaPle Counter Format STPC [staple-count or letter M (or m)]; Parameter 0, 1, "Interim Report 1", "Steve", "09/22/02 19:24"; TEXT "This is Interim Report 1 ..."; PAGE; UNIT C; BOX 5,10; PAGE; JOBT; EXIT; 1 This value depends on the stapler to be used. 340 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 351
the stapler unit. With position 2 (top left), stapling is automatically straightened (vertical) when Legal size paper is used. Parameter values 50 to 54 are valid for certain copier models only. The number of sheets that the stapler can staple at a time depends on the STPC command setting. The job - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 352
current output stack which may be specified by STAK. (For the document finisher such as the DF-31, the MSTK command may be used to guide stapled pages to one of the output trays as desired.) STPL command causes a page break. File !R! STPL 3; CMNT Two staples on the left; JOBS 0,3,0,0; TEXT - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 353
, 100, 150, 200, 300, 600, or 1200 Function The STR command sets the dot resolution for raster graphics to 75, 100, 150, 200, 300 600, and 1200 dpi resolutions are available only for the printing system models that support the 600 or 1200 dpi printing resolution. The default value is 75 dots per - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 354
, the STRK command clears the path and moves the cursor to the end of the path. File !R! RES; UNIT C; NEWP; PMZP 7, 17; SPD .2; PDRP -2.5, 0, 0, 2.5, 2.5, 0, 0, -2.5; PDRP 2.1, 1.25, 1.25, -2.1, -2.1, -1.25, -1.25, 2.1; PMRP 0, 2.5; PDRP 2.1, -1.25, 1.25, 2.1, -2.1, 1.25, -1.25, -2.1; STRK; PAGE - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 355
STRK Printout Related Commands FILL, NEWP 345 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 356
command sets the thickness of any subsequent underlining as well as the distance below the baseline, in the unit value designated by the UNIT command the underline character (_), which is an independent character with ASCII code 95 (hex 5F). If your word-processing software writes underlines by - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 357
SULP Printout 347 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 358
command is relevant to the FS-1000 printer only. Note File To attribute the MP tray for thick paper and normal density: !R! TATR 0, 1, 3; EXIT; To reset the second paper cassette (option feeder) to the defaults: !R! TATR 2; EXIT; To reset all paper sources to the defaults: !R! TATR; EXIT; 348 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 359
omitted, the cursor is not moved (same as option B). If the U-option is specified, the string is underlined. The underline thickness and location can be set by the SULP command. The TEXT command can be used to position a line of text at an exact location. The length of the string is - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 360
PRESCRIBE Command Reference File !R! RES; UNIT C; MAP 2, 2; SFNT 'Univers-MdCd'; TEXT 'Check desired options:', L, U; FONT 2; BOX .1, -.1; TEXT 'Power steering', L; BOX .1, -.1; TEXT 'CD auto changer', L; BOX .1, -.1; TEXT 'Air conditioner', L; PAGE; EXIT; Printout - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 361
a text command. To parse such characters, the current font must supports 2-byte characters and a 2-byte symbol set such as Windows 3.1J (19K). The pursing method will automatically be shift JIS encoding (2) if the default font and symbol set is of 2-byte. This command is valid only in HP emulation - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 362
the tray parameter, 1 is automatically set to the tray parameter. Function The TRSM command instructs printing system to insert blank or printed page between each transparency. The printing system loads transparency from MP tray and inserting paper from the paper source other than MP tray. When - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 363
UNIT UNIT - set UNIT of measurement Format UNIT code; Parameter code: I = inches C = centimeters P = points D = dots Function The UNIT command sets the unit of measurement used in other PRESCRIBE commands. The initial unit is inches. Other supported units of measurement can be calculated as - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 364
PRESCRIBE Command Reference Printout 354 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 365
1200, 1440, 1800, 2400, 3600, 7200 Function The UOM command applies only to the printing system models that support the 600 dpi resolution. It defines the unit of measurement in dots per inch for cursor movements. The command requires that the UNIT value be set to D. The default unit of measurement - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 366
PRESCRIBE Command Reference Printout Related Command UNIT 356 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 367
specification will be invalid. If an alias is to be set for a virtual mailbox for which a password is set, that virtual mailbox's password is required. An error will be displayed on the operator panel if no password or the incorrect password is specified. (See the Technical Reference manual.) Note - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 368
instances of this command. If no virtual mailbox corresponds to the alias given, an error will be displayed on the operator panel. (See the Technical Reference manual.) This command is irrelevant to photocopy virtual mailbox function. Note Files To stack jobs on virtual mailbox number 3: !R! VMOB - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 369
. For error displays, see the Technical Reference manual. The master password is valid as the current password for all virtual mailboxes. Virtual mailboxes for which a password has been set are not shown on the VMB LIST page (See page 134). This command is irrelevant to photocopy virtual mailbox - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 370
PRESCRIBE Command Reference Files To set 9999 as the password for virtual mailbox number 3 for which no password is set: !R! VMPW 3, 0, 9999; EXIT; To set no password for the virtual mailbox with the alias MyMailbox for which the password 9999 had been set: !R! VMPW "MyMailbox", 9999, 0; EXIT; To - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 371
left and right. • The width is always increased in the shorter direction (either width or height, whichever is shorter). Thus if the document is set to landscape orientation, the height is increased. • The printing area for sizes other than A4 is not affected. Portrait Original A4 printing area - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 372
a sequence of writing data to the memory card or to the hard disk, using one of the commands listed below. The WRED command can be renamed to a string of ASCII characters if necessary. For details, refer to the RWER T or RWRF T command (See page 249 or 257). Related command RWER S, RWER W, RWRF - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 373
ENDB must follow as a terminator for the barcode data string. Note that carriage return, line feed, space and all other characters must be counted as part of data in the data string field. If data-length is omitted, 0, negative value, or non integer, then data-string is counted all characters until - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 374
and intermediate age stars - this disk also contains gas and is actively forming new stars. Dust in the disk makes it appear orange in the picture. Dust absorbs blue light more than red light and thus makes stars appear reddish. Our Galaxy has spiral arms in its disk - these spiral arms - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 375
XBCP 0 XBCP 0 - select barcode type/reset all other XBCP parameters Format XBCP 0[, type]; Parameter type: two dimensional barcode type: 1 = PDF417 (only type currently supported) Function The XBCP 0 command selects a barcode type and resets all parameters to the defaults. File See XBCP 1 ( - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 376
dot. Default is 3 dots. Function PDF417 supports 8 different bar and space widths. The each unit as designated by a UNIT command. In the following example, the element width is set to .02 inches as the default unit 0; XBAR;Min. element width is reset (to 3 dots);ENDB; EXIT; Printout Minimum element - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 377
XBCP 3, as explained on the next page, sets the error correction level by predetermined values, and the execution of XBCP 3 disables the setting of XBCP 2, even if XBCP 2 is executed after XBCP 3, until RES (reset) or XBCP 0. File To set 50% error correction level: !R! RES; XBCP 2, 50; XBAR;This - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 378
0 to 8 Function The XBCP 3 command sets the error correction level by predetermined values. An illegal value defaults to 0. Note that the execution of XBCP 3 overrides the setting of XBCP 2 and remains valid until RES (reset) or XBCP 0. File To sets the error correction level to level 4: !R! RES - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 379
rows Format XBCP 4, number; Parameter number: number of data code word rows, ranging from 3 to 90 Function The XBCP 4 command sets the number of data code word rows in the PDF417 barcode. Illegal values make XBCP 4 ignored. XBCP 6 default provides default. Note that this command is not effective - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 380
(Illegal values make XBCP 5 ignored.) Function The XBCP 5 command sets the number of data code word columns in the PDF417 barcode. There are also row indicator code words at each end of the row which are not counted as data code words. XBCP 6 default provides default. Note that this command is - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 381
horizontal width Format XBCP 6, height, width; Parameters height/width: parts of the aspect ratio of vertical height and horizontal width, ranging issued together. Precedence of XBCP modes is: 4/56, 4/5+8 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 382
PRESCRIBE Command Reference Printout Aspect ratio is 3:2 in vertical and horizontal directions. Aspect ratio is normal. 372 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 383
from 1 to 10 Function The XBCP 7 command determines the bar height by a ratio to the narrowest element width. An illegal value defaults to 3. File To set the module height twice as high as the element width: !R! RES; XBCP 7, 2; XBAR;Visit Sea World, the world famous San Diego Zoo & Wild Animal Park - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 384
Function The XBCP 8 command permits the system to automatically set rows and columns so that it satisfies the requirement that 928. Default is disabled. Note that the XBCP 8 overrides XBCP 4 and/or 5 which set the number of rows and columns. However, this command is not effective if both XBCP 6 and - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 385
XBCP 9 XBCP 9 - enable truncation Format XBCP 9; Parameter None Function The XBCP 9 command can generate a truncated PDF417 symbol that omits the right row indicator and the stop pattern. Default is non-truncation. 375 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 386
contain EXC mode compaction characters (20H~7FH). This command is ignored if the string does not satisfy these conditions. The execution of this command automatically sets Macro PDF417 symbol mode. File !R! RES; XBCP 10, 'A00254'; MZP 1,0; XBCP 18,0; XBAR; ... ... EXIT; 376 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 387
symbol contains an optional block count field. The XBCP 11 command enables this function. Default is not enabled. The execution of this command also automatically sets Macro PDF417 symbol mode. File !R! RES; XBCP 11; MZP 1,0; XBCP 18,0; XBAR; ... ... EXIT; 377 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 388
symbol contains an optional time stamp field. The XBCP 12 command enables this function. The execution of this command also automatically sets Macro PDF417 symbol mode. File To set time stamp at 06:15:30AM on Jan. 2, 1970: !R! RES; XBCP 12, 108930; MZP 1,0; XBCP 18,0; XBAR; ... ... EXIT; 378 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 389
contain EXC compaction mode characters (20H~7FH). This command is ignored if the string does not satisfy these conditions. The execution of this command automatically sets Macro PDF417 symbol mode. File !R! RES; XBCP 13, "BETTERDAYSINC" MZP 1,0; XBCP 18,0; XBAR; ... ... EXIT; 379 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 390
EXC compaction mode characters (20H~7FH). This command is ignored if the string does not satisfy these conditions. The execution of this command also automatically sets Macro PDF417 symbol mode. File !R! RES; XBCP 14, 'BAREFOOTINC'; MZP 1,0; XBCP 18,0; XBAR; ... ... EXIT; 380 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 391
PDF417 symbol contains an optional file size field. The XBCP 15 command enables this function. Note that the execution of this command also automatically sets Macro PDF417 symbol mode. This function is disabled in default condition. File !R! RES; XBCP 15; MZP 1,0; XBCP 18,0; XBAR; ... ... EXIT; 381 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 392
Function A Macro PDF417 symbol contains an optional checksum. The XBCP 16 command enables this function. Note that the execution of this command automatically sets Macro PDF symbol mode. This function is disabled in default condition. File !R! RES; XBCP 16; MZP 1, 0; XBCP 18, 0; XBAR; ... EXIT; 382 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 393
is ignored if the string does not satisfy these conditions. The execution of this command automatically sets Macro PDF417 symbol mode. Note that PDF barcode is positioned a half inch below the previous PDF barcode if there are no positioning parameters exist [See XBCP 19 (page 387).] or insufficient - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 394
PRESCRIBE Command Reference Printout 384 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 395
Macro PDF417 two dimensional barcodes with a single file-id. File To bar-code data 'abcdXYZ12345' as a Macro PDF417 using block indices 0, 1, and 2: !R! UNIT C; CMNT Set unit to centimeters; XBCP 17,"file-id"; CMNT Set file ID to file-id; MZP 1,0; CMNT Move cursor to (1, 0) [centimeters]; XBCP - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 396
PRESCRIBE Command Reference Printout 386 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 397
on the printing system's manual). The remaining pairs of positioning parameters are ignored if there are no more PDF symbol to print. The Macro PDF mode and specifies QualitySt for file-id. The third line MZP command positions the first barcode at 1 inch each from the left and right paper edge - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 398
30-column-by-20-row PDF symbols at specified locations in Macro PDF mode. In example below, the first line XBCP command resets all XBCP parameters to the defaults and selects the barcode type for PDF417 (though it is the only type currently available); the second line XBCP sets the number of rows in - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 399
first page. The PAGE command on the sixth line starts the new page. The combinations of MZP and ENDB allow the second and third PDF barcodes printed at the specific coordinates on the following page.: !R! RES; XBCP 0,1; XBCP 17,"TrnOvr0"; XBCP 19; XBAR; large data such as 3000 bytes;ENDB; PAGE; MZP - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 400
PRESCRIBE Command Reference Printout 3 First page Second page 390 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 401
characters can include digits and special symbols such as hyphens. For example, F-1 and GRY-2 are valid buffer names. As the above Format instruction implies, the XBUF command sequence can have two other formats implementing the different functions as follows: XBUF buffer-name,; data-string;ENDB - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 402
barcode containing the data string buffered in the fourth line. ... XBCP 0, 1; XBUF PDF 1, 25; This is a PDF417 example. ;ENDB; XBUF PDF 2, 15; This is a test. ;ENDB; ... MCRO PDF; XBAR PDF 1; MRP 1, 1; XBAR PDF 2; ENDM; CALL PDF; The last line prints the two PDF417 barcodes defined in the macro - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 403
from 100 to 105 bitmap: dot pattern of the pattern, coded as a character string Function The XPAT command generates a new, and ARC commands and in a path. Details for creation of new patterns appear in Chapter 4 of the Technical Reference manual. File !R! RES; UNIT C; MAP 5, 5; XPAT 105;//?//?p@0p@ - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 404
PRESCRIBE Command Reference 394 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 405
Index - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 406
64 Character spacing, 281 Circle, 52 Clipping rectangle, 55 Code set, 129, 226, 268 returning to the saved set, 226 saving current, 268 Collator, 68 Color, 159 , 78, 285 a list as printout, 79 Dashed pattern, 79 Data dump, 218 ending, 93 Destination image, 300 Downloading character, 147 Drawing rule - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 407
, 246, 250, 256, 258 error codes, 136 I Image model, 299 International characters, 129 J Job, 136, 138, 140 printing a list of, 134 printing jobs, 136 , 145 K KCGL pen color, 297 KIR, 304 refinement level, 304 KPDL, 287 Kyocera Image Refinement, 304 L left, 307 Lightness, 155 Line, 73, 80, 82, 87 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 408
180 creating a palette, 180 Pantone colors, 36, 181 Paper cassette grouping, 27 Paper size, 282, 324 customize, 282 enlargement/reduction, 324 Paper 80, 82, 167 Resetting the printer by emulation, 220 Resolution, 222 RGB Status page, 336 user mode and service mode, 336 Symbol set, 65, 129, 226, 268 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 409
, 283 Unit of measurement, 283, 353, 355 per dots, 355 V Vector graphics commands, 5 Virtrual mailbox spooling as a job, 141 Virtual mailbox, 357, 358 aliasing a mailbox, 357 assigning a mailbox to receive jobs, 358 definiing a job to store in a mailbox, 140 password, 359 printing a list of, 134 - Kyocera KM-2560 | PRESCRIBE Commands Command Reference Manual Rev 4.8 - Page 410
Rev. 4.8 2009.7
Command Reference
PRESCRIBE Commands