Kyocera TASKalfa 6052ci PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013
Kyocera TASKalfa 6052ci Manual
View all Kyocera TASKalfa 6052ci manuals
Add to My Manuals
Save this manual to your list of manuals |
Kyocera TASKalfa 6052ci manual content summary:
- Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 1
PCL Barcode Flash 3.0 User Manual - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 2
PCL Barcode Flash status page as well. Copyright © KYOCERA Document Solutions Europe B.V. All rights reserved. No part of this manual may be us, including, but not limited to, any interruption of service, loss of business or anticipatory profits, or consequential damages resulting from - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 3
User Manual PCL Barcode Flash Please read this manual before installing and using the software. Keep the manual somewhere close to the printer. 3 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 4
codes (two-dimensional codes 13 1.8 SUPPORTED DEVICES 14 1.9 EMULATIONS AND RESTRICTIONS SUPPORTED 20 1.10 BARCODE COMPATIBILITY 20 2 INSTALLATION AND COMMISSIONING 21 2.1 HARDWARE INSTALLATION 21 2.2 ACTIVATING AND DEACTIVATING THE SOFTWARE (TYPE A ONLY 25 2.3 STATUS PAGE AND TEST PRINTS - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 5
check digit with space character 88 3.6.21 Code 39 Extended 89 3.6.22 Code 39 Extended + Mod47 check digit 90 3.6.23 Code 93 91 3.6.24 Code 93 Extended 92 3.6.25 Code 128 autoswitch 93 3.6.26 Code 128 Subset A 94 3.6.27 Code 128 Subset B 95 3.6.28 Code 128 Subset C 96 3.6.29 UCC-128 97 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 6
information on programming in PRESCRIBE and PCL, which is not included in this manual. If you have any queries on or problems with your PCL Barcode Flash solution, which are not resolved in this manual, please consult your service partner, the local Kyocera Document Solutions Hotline or your nearest - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 7
and programming instructions described are illustrated with examples and - where necessary - printed barcode samples. This manual does not codes to be used. Information on programming in PRESCRIBE and PCL can be found in the appendix and in the additional Kyocera Document Solutions manuals included - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 8
the application PCL Barcode Flash enhances Kyocera FS, KM and TASKalfa devices to include additional linear barcodes and matrix codes, as well as providing the sequences follow industry-standard formats, there are usually no problems with integrating devices equipped with the Barcode Flash solution - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 9
1.4 Items provided as standard Once you have removed the packaging, please ensure that you have the following components: - a CD containing manual files (in PDF format) and sample prints - a Compact Flash/Secure Digital card (pre-programmed with PCL Barcode Flash software) 9 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 10
as standard are described in detail in the PRESCRIBE IIe Programming Manual (see appendix). 1.5.2 Terminology In this manual, in most cases we simply refer to "barcodes". In technical terminology, we refer to linear codes, stack codes and matrix codes, which differ in terms of what is known as - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 11
of square elements, segments of circles, stripes or hexagons of different sizes, or combinations of these. The development history and structure of these codes have been influenced by various demands, such as high data density, fast readability, great data security or the most well-featured codable - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 12
without time limit available which can be used to test compatibility with existing (print) solutions prior to purchase 1.7 Supported Barcodes 1.7.1 Linear codes (one-dimensional codes) 2/5 Interleaved with check digit 2/5 Interleaved without check digit 2/5 Industrial with check digit 2/5 Industrial - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 13
37-CUST Australia 4-State 52-FF-MET Australia 4-State 67-FF-MET Australia 4-State FCC-45 REPLY Singapore Post 4-State USPS Intelligent Mail Barcode 1.7.2 Matrix codes (two-dimensional codes) Datamatrix QR Code Maxicode PDF417 13 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 14
Devices PCL Barcode Flash supports Kyocera printers and multifunction devices. At the time of publishing (version 3.02.17, 03-2013), the following devices are supported: Multifunction Devices (alphabetical order) Model Name Card Type FS-1016MFP - FS-1018MFP - FS-1020MFP - FS-1024MFP - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 15
FS-C1020MFP - FS-C1020MFP+ - FS-C2026MFP B/C FS-C2026MFP+ B/C FS-C2126MFP B/C FS-C2126MFP+ B/C FS-C2526MFP B/C FS-C2626MFP B/C FS-C8020MFP B/C FS-C8025MFP B/C FS-C8520MFP B/C FS-C8525MFP B/C KM-1500 - KM-1620 - KM-1635 - KM-1650 A KM-2020 - KM-2035 - KM-2050 A - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 16
KM-4850w - KM-5035 A KM-5050 B/C KM-5230 A KM-5530 A KM-6030 A KM-6230 - KM-6330 A KM-7530 A KM-8030 A KM-C2520 A KM-C2525E A KM-C2630 A KM-C3225 A KM-C3232 A KM-C3232E A KM-C4035E A KM-C830 A KM-C850 A KM-P4845w - KM-P4850w - TASKalfa 180 - TASKalfa 181 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 17
TASKalfa 4550ci TASKalfa 500ci TASKalfa 520i TASKalfa 5500i TASKalfa 550c TASKalfa 552ci TASKalfa 5550ci TASKalfa 620 TASKalfa 6500i TASKalfa 650c TASKalfa 6550ci TASKalfa 750c TASKalfa 7550ci TASKalfa 8000i TASKalfa 820 Printers (alphabetical order) Model Name FS-1010 FS-1020D FS-1030D FS-1040 FS- - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 18
FS-2000D A FS-2020D B/C FS-2100D/DN D FS-3800 A FS-3820N A FS-3830N A FS-3900DN A FS-3920DN B/C FS-4000DN A FS-4020DN B/C FS-4100DN D FS-4200DN D FS-4300DN D FS-6020 A FS-6950DN A FS-6970DN B/C FS-7000 A FS-820 A FS-9000 A FS-9100DN A FS-9120DN A FS-9130DN - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 19
list is available in the service area of www.kyoceradocumentsolutions.eu Note Please note that some KM series multifunction devices have to be fitted with a printer board first Note For some of the older supported devices, it might in certain cases be necessary to make a firmware update. Note PCL - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 20
or the printer settings/printer environment: - PCL Barcode Flash supports printer control languages PCL and PRESCRIBE only. No barcodes can solution is one of these - simultaneously. Therefore, solutions produced by Kyocera development partners, e.g. for data filtering or data encryption, cannot be - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 21
device. Data and programs for Kyocera printers always have to be present in a particular form on Compact Flash cards. In the case of the barcode solution, these are a number of what are known as 'partitions' in which additional fonts and macros for the status page and function calls are stored for - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 22
EAN_13mil LetterGothic_10 LetterGothic_12 LetterGothic_17 USPS_ZIP OCR_A OCR_B OCR_B scal Startup ocr_a_9_land ocr_a_10_land ocr_a_9_port ocr_a_10_port ocr_b_12_ext_la ocr_b_12_land ocr_b_12_ext_po ocr_b_12_port Type B/C: /PRE/kmbc3-02-1 /PRE/kmbc3-02-1.inf /PRE/autostart /PRE/bstp /PRE/stp1 /PRE/ - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 23
additional macro and font partitions to the CF/SD card without impairing the functionality of PCL Barcode Flash. To see an overview of the partitions, print a partition list. Start printing this list using the front panel on the printer. 23 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 24
list of Type A: The Device Information contains information on the physical size of the CF/SD card and the memory used. The Partition Information lists print data, macro data and font data which is stored on the card alongside PCL Barcode Flash. This information is technical in nature and the actual - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 25
a later version, the name of the newer partition must be used instead of "KM BC 3.02.1". To see the exact name of the program partition, print a partition list. Automatic loading of the software on the CF card is now activated, and once the device has been switched on the barcode solution - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 26
problems or errors occur, we recommend that you always print a status page. In this way, you can easily check whether the software and all the requisite fonts have been loaded. When you consult Support, you should always have a current status page to hand. As a rule, the status page helps Support - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 27
Example of a status page of Type A: 2.4 Startup partition (Type A only) As described in the chapter entitled, HARDWARE INSTALLATION, there is a Startup partition on the CF like to make available to users must be copied into this partition. As a rule, this data includes fonts, macros or print data. 27 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 28
exclusively using the Kyocera language PRESCRIBE. The PCL Barcode Flash software extends the number of barcodes supported to include important of applications and prints. Control by means of commands is already described precisely in the Kyocera manual "PRESCRIBE IIE PROGRAMMING MANUAL" (CHAPTER 4: - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 29
instructions assume a basic knowledge of PCL programming. If you are not yet confident with using this, we recommend that you read the manuals the text which follows the sequence is printed from this point on in the supported individually. If you would like to use one of the barcodes or matrix codes - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 30
, this is interpreted not only as a stop character, but also as a page break. When, for example, the stop character is used, this is sequence prints the character string "12345" as a Code 39 symbol. 3.2.2 Stopping Barcode mode To stop (deactivate) Barcode mode to enable you to print text again - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 31
encounters incorrect base data, an error message is printed out instead of the barcode symbol. and after the printed area (above and below too in the case of two-dimensional codes), and you barcode is printed, the cursor moves to the lower right corner of the barcode symbol. See the PCL manual for - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 32
text, for example, or if the width and length in default form are already sufficient for the requirements of your application. Example with two bar widths, e.g. Code 39, enter two values, e.g. (s6,12b...; or in the case of a code with four bar widths, e.g. Code 128, enter four values, e.g. - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 33
p parameter Positioning of plain text 0 = Use default, cf. the defaults entered for the individual codes for this purpose 1 = no plain text Example: 2 = embedded beneath Example: 3 = half embedded beneath Example: 4 = beneath the barcode Example: 5 = above the barcode - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 34
h parameter Plain text font When you use the h parameter, this always requires a three-digit number, as you can see from the example above. First digit: Font style 1 = regular 2 = italics 3 = bold 4 = bold italics Second digit: Font size 0 = select automatically 1 = use previously selected size for - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 35
with check digit without space character Code 39 (3 of 9) with space character Code 39 + Mod47 with check digit with space character Code 39 Extended Code 39 Extended + Mod47 check digit Code 93 Code 93 Extended Code 128 autoswitch Code 128 Subset A Code 128 Subset B Code 128 Subset C UCC-128 EAN - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 36
call, so any unwanted fonts are activated and the printer attempts to print your base data instead of outputting the barcode. Warning If invalid values are entered for any of the parameters, PCL Barcode Flash prints out an error message instead of the barcode symbol. The same happens when the - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 37
" (ASCII 34) \ (ASCII 92) # (ASCII 35) { (ASCII 123) $ (ASCII 36) | (ASCII 124) / (ASCII 47) } (ASCII 125) ? (ASCII 63) ~ (ASCII 126) If so required, the Alternative Escape Character mode can be deactivated by means of the PRESCRIBE sequence !R!VBST;E;EXIT; or the Escape - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 38
an error message instead of a symbol. This kind of range selection is sensible, for example, for applications in which the size of the data to be coded varies, but where the same symbol size is always required for visual or legibility reasons when printed, for example. The size of the modules, the - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 39
elements such as paper quality and colour, reading distance, scanning technique and light conditions are to be taken into account. When programming, you should pay entirety, mainly as squares or rectangles. PCL Barcode Flash supports Datamatrix only in accordance with the widely applied ECC200 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 40
30 47 Example of a rectangular Datamatrix symbol (symbol no. 29) Datamatrix codes can be called with both PRESCRIBE and PCL commands. Syntax in PCL The , i.e. values outside the ranges mentioned below, an error message is printed instead of the Datamatrix symbol. T parameter: identifier for - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 41
symbol (no. 24) is an error message printed instead of the symbol. b parameter: print the symbol completely on the page in the case of very large module sizes. If you do not enter a value, 10 is used as the default. v parameter: inversion 1 = Symbol is not printed inverted 2 = Symbol is printed - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 42
MANUAL". The BARC command is used. The syntax described in the PRESCRIBE manual for the BARC command is valid for the one-dimensional barcodes supported in the section entitled "Syntax in PCL". Type of coding 0 must always be entered. Error correction level 0 must always be entered. Amount of base - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 43
10. Note BARC 100 cannot be called from PRESCRIBE macros. 3.3.2 Datamatrix mode for printing from SAP A second variant for printing Datamatrix from PRESCRIBE is also available. This method has been designed especially for printing from SAP. It uses the ID number 120 (instead of 100). The essential - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 44
must occur. Example: BARC 120,10,10,14; TEXT „0123456789"; TEXT „0123456789"; The advantage of this mode: As lengthier useful data often have to be printed with Datamatrix, cases may occur in SAP where a single row cannot accommodate all of the useful data. If this should be the case, one of - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 45
must make your selection so that your data can be accommodated. If you select a version that is too small, the software prints an error message instead of the QR Code symbol. If you fail to make a selection, the software automatically selects the smallest possible version in which the base data can - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 46
version 14, PCL Barcode Flash prints out an error message instead of a QR Code symbol. This kind of error correction level rises, consequently your space requirement and reading speed can decrease. There again, a higher error correction level may be recommended for poorer paper qualities or lighting - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 47
Code is available as model 1 and 2, where model 1 is only used in older applications. PCL Barcode Flash only supports the current model 2. International standards recommend only using model 2, which has been improved in a number of respects. If PCL Barcode Flash is given the instruction in a print - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 48
by default. b parameter: Size of a module in dots relative to 600 dpi Permissible values: 1 - 1000, where it should be noted that a size of less than 6 is too small to be recognised by most reading devices and that at very large module sizes the symbol cannot be printed in full on the page. If - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 49
If you do not specify the v parameter, then 1 is used by default, i.e. not inverted. Examples: (s4p10h1v12b3s24861TDaten (s12,15h2v24861TDaten The following example including a print-out: (s4p1v30b3s24861T This is a QR Code symbol. Syntax in Prescribe In case you are not familiar with - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 50
from 0 to 4. For an explanation of the meaning of this parameter, cf. the explanatory notes on the s parameter in the section "SYNTAX IN PCL". Error correction level Values from 1 to 4. For an explanation of the meaning of this parameter, cf. the explanatory notes on the b parameter in the section - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 51
to the other 2D codes supported, the size of printed modules comprise hexagons and there are circles at the centre (see figure below) that enable the reading device to locate it more rapidly. MaxiCode contains code words for the automatic correction of errors. All 256 ASCII characters can be coded - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 52
this sequence; apart from that, the same rules apply as those used for other barcodes. The data following this sequence are interpreted and coded as useful data for the MaxiCode. The subsequent escape sequence terminates the data. The data are divided into primary and secondary information and must - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 53
. Mode 2 is used mainly in applications in the USA and mode 3 is generally used outside of the USA. 4. Postal code 5. Country code 6. Service class Secondary information The secondary information often begins with the character string "[)>"+ RS character (=field separator, ASCII character 30). The - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 54
8T Detailed explanation relative to this example: 1 = No. of symbol 1 = Number of symbols in this group 2 = MaxiCode mode 40670 = Postal code 840 = Country code 001 = Service class 1Z00004951 = Tracking number USPN = SCAC 06X610 = UPS Shipper number 159 = Julian day of pickup 54 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 55
same data are used as in the previous PCL example. XBCP 0,8; Reset and selection of MaxiCode. This command must appear before each MaxiCode request a group of symbols, the sequential number of the symbol currently to be printed must be entered here. In the absence of this parameter, 1 is used - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 56
error will, of course, occur if a value other than 1 is entered under XBCP 2,#. XBCP 4,#; # stands for the postal code. Depending on the mode (which has been entered in XBCP 1,#), a numerical or alphanumerical postal code 6,#; Service class, which is responsible for printing out the symbol using the - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 57
GS>MEERBUSCHDE;ENDB; PAGE;EXIT; Notes The order in which code invented by Symbol Technologies. PDF stands for 'Portable Data File'. In contrast to the other 2D codes supported is considerably broader than with the other matrix codes described. Identical line patterns are always located - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 58
error correction desired'. Depending on the application and on the quality of the paper used, however, a higher level should be used. All 256 ASCII characters can be coded an error message is printed in lieu of the PDF417 symbol. T-parameter: Identifier for PDF417 24850T p-parameter: Error correction - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 59
words. The barcode module uses this regardless of the size of the useful data. However, you also have the option of making the number of error correction words dependent on the size of the useful data. This is particularly useful if your application is designed to output different kinds of useful - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 60
apply as a maximum size, however. Please note that in this case an error message will be output in lieu of the symbol if the useful data encoded of this parameter or if you enter another value, the symbol will be printed in the normal way with bars. s-parameter: Layout of the individual modules - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 61
symbol with the proportion of 2 to 3 as standard. As the remaining rules for the layout of the symbol also apply, these values are always only approximations. The Barcode Flash solution always selects the most appropriate value here. 3. Y-value for the proportion of the symbol (cf. sub-parameter 2). - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 62
Post uses a unique eight character Delivery Point Identifier (DPID), which is allocated to each delivery address in the postal address file (PAF). The DPID is printed in barcode format on letters as part of an address. It is encoded to create the main part of the customer barcode. PCL Barcode Flash - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 63
PCL T parameter: 24787 Activation: (s24787T PRESCRIBE number: 47 Activation: !R!BARC 47,C,"Base Data,ABCDEFGHIJ"; EXIT; Example: (s24787T23456789,Info 4. Australia 4-state FCC-45 REPLY (reply paid) PCL T parameter: 24788 Activation: (s24788T< - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 64
Please note that no plain text is printed with the Australia 4-state barcode. Note BARC 45, 46, 47 and 48 cannot be called from PRESCRIBE macros. 64 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 65
out in place of the barcode symbol to make the task of detecting errors easier for you. The error messages are printed in plain text in a checked rectangle, e.g.: , or The following error messages exist: Data too long The length of the base data exceeds the defined maximum size for this barcode - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 66
amount of base data or select a different symbol size. Unknown Kanji A Kanji character represented by two bytes occurred in the base data for the QR Code, the encoding of which did not conform to the rules of the JIS Shift 0208 standard. Comma expected In the Australia Post 4-state barcode the - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 67
. No Stop Letter You have specified an illegal character as the stop character for Codabar. Codabar only allows the letters A,B,C and D as stop characters. Internal error These errors should not really occur. Should any occur, then please contact your - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 68
instructions on use Do not set the toner density to the lowest contrast value. It is recommended that you set it to a density of 3 or higher. The setting can be made using the control panel or the PRESCRIBE sequence !R! FRPO D4,3;EXIT; The Toner Save mode should not be used when printing manually - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 69
3.6 Barcode Types 3.6.1 UPC-A Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code. Activation sequence: (s24600T For an explanation on selecting the stop character and the optional parameters, - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 70
3.6.2 UPC-A + a 2 digit extension Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code. Activation sequence: (s24601T For an explanation on selecting the stop character and the optional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 71
is only output in the default typeface in a set position below the code. Activation sequence: (s24610T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 72
3.6.4 UPC-E + a 2 digit extension Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code. Activation sequence: (s24611T For an explanation on selecting the stop character and the optional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 73
3.6.5 EAN/JAN-8 Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code. Activation sequence: (s24620T For an explanation on selecting the stop character and the optional parameters, see chapters - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 74
3.6.6 EAN/JAN-8 + a 2 digit extension Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code. Activation sequence: (s24621T For an explanation on selecting the stop character and the optional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 75
3.6.7 EAN/JAN-8 + a 5 digit extension Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code. Activation sequence: (s24622T For an explanation on selecting the stop character and the optional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 76
3.6.8 EAN/JAN-13 Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code. Activation sequence: (s24630T For an explanation on selecting the stop character and the optional parameters, see chapters - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 77
3.6.9 EAN/JAN-13 + a 2 digit extension Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code. Activation sequence: (s24631T For an explanation on selecting the stop character and the optional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 78
3.6.10 EAN/JAN-13 + a 5 digit extension Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code. Activation sequence: (s24632T For an explanation on selecting the stop character and the optional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 79
3.6.11 Interleaved 2 of 5 Type / properties: Linear code Activation sequence: (s24640T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 80
2 of 5 with check digit Type / properties: Linear code Activation sequence: (s24641T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 81
2 of 5 (25) Type / properties: Linear code Activation sequence: (s24650T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 82
of 5 (25) with check digit Type / properties: Linear code Activation sequence: (s24651T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 83
3.6.15 Matrix 2 of 5 Type / properties: Linear code Activation sequence: (s24660T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 84
2 of 5 with check digit Type / properties: Linear code Activation sequence: (s24661T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 85
9) without space character Type / properties: Linear code Activation sequence: (s24670T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 86
with space character Type / properties: Linear code Activation sequence: (s24672T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,18 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 87
without space character Type / properties: Linear code Activation sequence: (s24671T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 88
with space character Type / properties: Linear code Activation sequence: (s24673T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,18 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 89
Extended Type / properties: Linear code Activation sequence: (s24680T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,18 Additional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 90
+ Mod47 check digit Type / properties: Linear code Activation sequence: (s24681T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,18 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 91
93 Type / properties: Linear code Activation sequence: (s24690T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12,18,24 Additional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 92
93 Extended Type / properties: Linear code Activation sequence: (s24691T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12,18,24 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 93
128 autoswitch Type / properties: Linear code Activation sequence: (s24700T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 94
128 Subset A Type / properties: Linear code Activation sequence: (s24701T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 95
128 Subset B Type / properties: Linear code Activation sequence: (s24702T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 96
128 Subset C Type / properties: Linear code Activation sequence: (s24704T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 97
3.6.29 UCC-128 Type / properties: Linear code Activation sequence: (s24710T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12,18,24 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 98
3.6.30 EAN-128 Type / properties: Linear code Activation sequence: (s24720T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12,18,24 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 99
3.6.31 Codabar Type / properties: Linear code Activation sequence: (s24750T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 100
+ Mod16 check digit Type / properties: Linear code Activation sequence: (s24751T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 101
3.6.33 MSI Plessey Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code, which means that the h parameter does not have any effect and in the case of the p parameter only the values 1 and 4 are allowed. Activation sequence: < - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 102
3.6.34 MSI Plessey + Mod10 check digit Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code, which means that the h parameter does not have any effect and in the case of the p parameter only the values 1 and 4 are allowed. - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 103
3.6.35 MSI Plessey + Mod10 + Mod10 check digit Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code, which means that the h parameter does not have any effect and in the case of the p parameter only the values 1 and 4 are - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 104
3.6.36 MSI Plessey + Mod10 + Mod10 check digit Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code, which means that the h parameter does not have any effect and in the case of the p parameter only the values 1 and 4 are - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 105
, used in postal traffic within the U.S.A. Limitation: Plain text is not recommended. This code can only output plain text in the default typeface in a set position below the code. Activation sequence: (s24770T For an explanation on selecting the stop character and - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 106
, used in postal traffic within the U.S.A. Limitation: Plain text is not recommended. This code can only output plain text in the default typeface in a set position below the code. Activation sequence: (s24771T For an explanation on selecting the stop character and - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 107
, used in postal traffic within the U.S.A. Limitation: Plain text is not recommended. This code can only output plain text in the default typeface in a set position below the code. Activation sequence: (s24772T For an explanation on selecting the stop character and - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 108
examples: The following text is printed out with different parameters as the DataMatrix symbol: 'Data Matrix is a two-dimensional matrix symbology which is made up of square modules arranged within a perimeter - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 109
3.6.41 QR code Printing examples: The following text is printed out with different parameters as the QR Code symbol: 'QR CODE IS A MATRIX RANGE OF SIZES OF SYMBOL IS PROVIDED FOR TOGETHER WITH FOUR LEVELS OF ERROR CORRECTION. MODULE DIMENSIONS ARE USER-SPECIFIED TO ENABLE SYMBOL PRODUCTION BY A WIDE - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 110
the integrated default printer typefaces controlled using some Microsoft Windows standard printer drivers, and Kyocera devices can now be used for this Print out the "PCL Barcode Flash Status Page" ('Memory Card' > 'Read data' > 'Barcode Status' menu item) Activate one of the fonts and print - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 111
3.7.2 Activating fonts using a PRESCRIBE command Either using the individual FONT command or the pair of commands, CSET and FSET (CSET and FSET should always be used together as otherwise the font activation cannot be correctly recognised by the printer). The zero character is displayed as 0 and it - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 112
3.7.3 Activating fonts using a PCL command In the PCL emulation of Kyocera devices, the fonts can also be selected using the corresponding PCL command. The Escape character (ASCII character 27 in decimal or 1B in hexadecimal is - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 113
out a barcode 39 with PRESCRIBE: !R! FONT 831; TEXT "*0987654321*"; PAGE; EXIT; ("*" required as the start and stop character) Print out of a UPC barcode with ORC-A script embedded below in PCL: [cr][lf] [esc](8Y[esc](s1p12v0s0b0T(012345-GHIJAF([cr][lf] (012345-GHIJAF([cr][lf] ( - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 114
www.iso.ch It is generally recommended that you familiarise yourself with the following official manuals, which are normally included on CD as a PDF document with every Kyocera device: - PRESCRIBE IIe Programming Manual (English) - PDF417 Two Dimensional Bar Code Implementation Manual (English) 114 - Kyocera TASKalfa 6052ci | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 115
115 3.2 EN (03/2013)