Lantronix EDS3000PS EDS3000 ENVIRONMENTAL CERT MTBF

Lantronix EDS3000PS Manual

Lantronix EDS3000PS manual content summary:

  • 1
  • 2

FM-351 Rev C
July 15, 2021
ENV-00316 Rev A
MTBF Declaration
To Whom It May Concern:
A calculation was performed using a predictive method per Telcordia SR332 Issue 2.
Product:
EDS3000
Environment:
Ground Benign, Controlled
SKU
Failure Rate
@30C
MTBF
@30C (Hour)
MTBF
@30 C (Year)
Failure Rate
@85C
MTBF
@85C (Hour)
MTBF
@85C (Year)
EDS3008PR1NS
1.08
925943
105.70
10.41
96039
10.96
EDS3008PS1NS
1.16
863428
98.56
18.27
54744
6.25
EDS3016PR1NS
1.53
652631
74.50
15.11
66166
7.55
EDS3016PS1NS
1.76
567646
64.80
30.39
32910
3.76
EDS3032PR1NS
2.44
410002
46.80
24.54
40742
4.65
Definitions
Failure Rate (FIT):
Failures per billion hours.
The total number of failures within an
item population per the total number of life units expended by that population
during a measurement interval under stated conditions.
Failure:
The events, or inoperable state, in which any item or part of an item does
not, or would not, perform as specified.