Secure Managed Client - Storage Array Hardware Installation and Replacement Guide Machine Type 8332 - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 2
- Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 3
Secure Managed Client - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 4
this information and the product it supports, be sure to read and understand the Safety and Warranty Guide for this product. First Edition (October 2008) © Copyright Lenovo 2005, 2008. All rights reserved. LENOVO products, data, computer software, and services have been developed exclusively at - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 5
an Intel RAID Controller SRCSATAWB. . 29 Installing the boot drives 31 Appendix A. Server board connector and header locations 39 Appendix B. Notices 41 Trademarks 42 © Copyright Lenovo 2005, 2008 iii - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 6
iv Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 7
. . . . 35 40. Connecting power cable to boot drive module backplane 36 41. Re-installing boot drive module 36 42. Re-installing brace assembly 37 © Copyright Lenovo 2005, 2008 v - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 8
vi Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 9
manual, it is important that you read and understand all the related safety information for this product. Refer to the Safety and Warranty Guide Safety and Warranty Guide, you can obtain one online from the Lenovo® Support Web site at: http://www.lenovo.com/support/ © Copyright Lenovo 2005, 2008 1 - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 10
2 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 11
that cables, switches, and certain mechanical parts be replaced by trained service personnel without the need for step-by-step procedures. Note: Use only parts provided by Lenovo. This guide contains instructions for installing or replacing the following parts: v Enclosure cover v Processor air - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 12
4 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 13
must be in place for the air to flow correctly around the storage system and to complete the internal circuitry. Before beginning your storage system installation, review the configuration requirements listed in the Secure Managed Client - Storage Array User Guide. © Copyright Lenovo 2005, 2008 5 - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 14
enclosure cover must only be removed by a qualified service person as it provides access to a service area. Potential hazards include: v Energy hazard v Rotating cover to completely remove it from the chassis. 6 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 15
. 1. Observe all safety and ESD precautions in the Safety and Warranty Guide. 2. Align the enclosure cover over the sides of the chassis. Slide of the chassis (see 2 in the following figure). With a screwdriver, secure the enclosure cover to the chassis by tightening the lock a quarter turn until - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 16
the processor air duct, do the following: Attention: Before performing any maintenance on the system, back up the data. Follow the instructions in the Secure Managed Client - Storage Array User Guide for turning off the system. 1. Observe all safety and ESD precautions in the Safety and Warranty - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 17
: CAUTION: Do not operate the SMC - Storage Array without the processor air duct securely installed. Attention: Before performing any maintenance on the system, back up the data. Follow the instructions in the Secure Managed Client - Storage Array User Guide for turning off the system.: 1. Observe - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 18
supply unit, do the following: CAUTION: Removing a power supply unit must only be performed by a qualified service person. Potential hazards include: v Energy hazard v Hot surfaces v Access to PSU openings 10 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 19
Attention: v Before performing any maintenance on the system, back up the data. Follow the instructions in the Secure Managed Client - Storage Array User Guide User Guide for turning off the system. v Prior to removing a PSU from the enclosure and to ensure the system has warning of an imminent - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 20
repair. CAUTION: This procedure should only be performed by qualified service personnel. Attention: v Before performing any maintenance on the system, the unit.: Notes: 1. Follow the instructions in the Secure Managed Client - Storage Array User Guide User Guide for turning off the system. 2. If - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 21
Figure 8. Installing a power supply unit Figure 9. Power supply unit in place 4. Connect the AC power cable to the new PSU. Secure the power cord plug with the power supply bail. 5. On non-redundant power supply systems, power up the storage system. Chapter 3. Hardware installations and upgrades 13 - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 22
of a PSU from the system 1. Observe all safety and ESD precautions in the Safety and Warranty Guide. 2. Attach a power cord to the installed PSU. The Power On LED (see 1 in the national electrical standards. 14 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 23
a cooling fan The SMC - Storage Array has ten fans in its cooling cage to ensure proper cooling of the system. Each cooling fan can be individually replaced. To replace a cooling fan, do the following: CAUTION: The enclosure cover should only be removed by qualified service personnel as it provides - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 24
6. Slide the enclosure cover (see 2 in the following figure) until it is closed, and then turn the lock mechanism to the "locked" position (see 1 ). 16 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 25
if any dummy modules are not installed.: 1. Observe all safety and ESD precautions in the Safety and Warranty Guide. 2. See "De-activating an anti-tamper lock" on page 21 for instructions on de-activating the lock if the lock as been activated 3. Release the carrier handle by pressing the latch - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 26
wait 30 seconds before proceeding. Figure 16. Removing a drive carrier module 5. After 30 seconds, remove the drive carrier module completely from the drive bay. 18 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 27
activated outside the enclosure. See "De-activating an anti-tamper lock" on page 21 for instructions on de-activating the lock. 1. Observe all safety and ESD precautions in the Safety and Warranty Guide. 2. Release the drive carrier handle by depressing the latch in the handle. Figure 17. Unlatching - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 28
handle (see 1 i the following figure). 2. Turn the screwdriver in a clockwise direction until the lock symbol is visible in the aperture beside the key (see 2 ). 20 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 29
: 1. Observe all safety and ESD precautions in the Safety and Warranty Guide. 2. See "Removing a drive carrier module" on page 17 for instructions on removing a drive carrier from a drive bay. 3. Remove the four screws securing the hard disk drive to the drive carrier (see 1 in the following - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 30
hard disk drive into a drive carrier" for instructions on installing a hard disk drive into a Secure the hard disk drive to the drive carrier with four screws (see 2 ). Set any jumpers for the hard disk drive. 22 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 31
safety and ESD precautions in the Safety and Warranty Guide. 2. Turn off all peripheral devices connected to the storage system. Turn off the storage system. 3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see "Removing the enclosure cover" on page 6. 5. Remove - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 32
duct. For instructions, see "Removing the processor air duct" on page 8. 6. Locate the DIMM sockets. Figure 25. Locating FBDIMM sockets Table 1. 1 DIMM_A1 2 DIMM_A2 3 DIMM_B1 5 DIMM_C1 6 DIMM_C2 7 DIMM_D1 24 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 33
For instructions, see "Installing the enclosure cover" on page 7. 16. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system the Safety and Warranty Guide 2. Turn off all peripheral devices connected to the storage system. Turn off the storage system. 3. Disconnect the - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 34
in CMOS RAM (for example, the date and time) may be wrong. Contact your customer service representative or dealer for a list of approved replacement batteries. To replace a CMOS battery, do the following: 26 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 35
safety and ESD precautions in the Safety and Warranty Guide. 2. Turn off all peripheral devices connected to the storage system. Turn off the storage system. 3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see "Removing the enclosure cover" on page 6. 5. Remove - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 36
the SAS cable (see 2 ). Pull the SAS Expander PCB assembly forward, unplugging it from the backplane (see 3 ). Figure 28. Removing the SAS expander PCB 28 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 37
and ESD precautions in the Safety and Warranty Guide. 2. Turn of all peripheral devices connected to the storage system. Turn off the storage system. 3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see "Removing the enclosure cover" on page 6. 5. Disconnect - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 38
following figure), ensuring it is seated firmly in the slot. Replace the screw removed in the previous step (see 2 ). Reconnect the SAS cable (see 3 ). 30 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 39
safety and ESD precautions in the Safety and Warranty Guide. 2. Turn off all peripheral devices connected to the storage system. Turn off the storage system. 3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see "Removing the enclosure cover" on page 6. 5. Remove - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 40
(see 3 ). Figure 33. Removing boot drive module 8. With a #1 Phillips* screwdriver, remove the two screws securing the backplane to the boot drive module. Remove the backplane from the boot drive module. 32 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 41
Install lower boot drive in boot drive module with circuit side facing down and connectors oriented toward backplane (see 1 in the following figure). Secure disk drive to boot drive module with four screws (see 2 ). Figure 35. Installing lower boot drive 10. (Optional) Install second boot drive in - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 42
top of the circuit board is flush with the top of the boot drive module. Secure backplane to boot drive module with two screws previously removed. Figure 37. Attaching backplane to data cable connects to 2 . 34 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 43
Figure 38. Connecting data cables to boot drive module backplane 13. Connect data cable(s) to the server board as follows: v Bottom boot drive to SAS 0 on server board v Top boot drive to SAS 1 on server board Figure 39. Connector locations on server board Table 2. 1 SATA-0 2 SATA-1 3 SATA-2 / SAS - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 44
removed. Figure 41. Re-installing boot drive module 16. Re-install brace assembly in enclosure (see 1 in the following figure). Secure brace assembly to enclosure by tightening the two captive screws (see 2 ). 36 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 45
, see "Installing the processor air duct" on page 9. 18. Re-install the enclosure cover. For instructions, see "Installing the enclosure cover" on page 7. 19. Reconnect all peripheral devices and the AC power cord(s). Power up the storage system. Chapter 3. Hardware installations and upgrades 37 - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 46
38 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 47
battery 9 P12V4 connector 10 RMM connector (connector for Intel Remote Management Module) 11 Back panel I/O ports 12 Diagnostic and identify panel header 32 Hot-swap backplane B header 33 Enclosure management SAS SGPIO header 34 Enclosure management SAS SES2 35 Hot-swap backplane A header 36 SATA - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 48
header 15 Main power connector 28 USB header 29 IDE connector 30 Enclosure management SATA SGPIO header 43 Front control panel header 44 Serial B/emergency management port header 45 Chassis intrusion header 40 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 49
and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering subject matter described document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 50
. The following terms are trademarks of Lenovo in the United States, other countries, or both: Lenovo Lenovo logo Other company, product, or service names may be trademarks or service marks of others. 42 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide - Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 51
- Lenovo Secure Managed Client | (English) Hardware replacement guide - Page 52
Part Number: 45K1344 Printed in USA (1P) P/N: 45K1344
Secure Managed Client - Storage Array
Hardware Installation and Replacement Guide
Machine Type
8332