Lenovo Storage CLI Reference Guide For firmware release GL210 or later Abstract This guide provides information about managing a Lenovo Storage S3200/S2200 storage system by using its command-line interface (CLI). Part Number: 00WE612 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 2
RIGHTS NOTICE: If data or software is delivered pursuant a General Services Administration "GSA" contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No. GS-35F-05925. Lenovo, the Lenovo logo, BladeCenter, Flex System, NeXtScale System, and System x are - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 3
Contents About this guide 11 Intended audience 11 Prerequisites 11 Related documentation 11 Document 21 Specifying ports 21 Specifying initiators and hosts 21 Specifying host groups 21 User password rules 21 Command completion, editing, and history 22 Viewing help 22 Size representations - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 4
94 reset host-link 95 reset host-port-statistics 96 reset pool-statistics 97 reset smis-configuration 98 reset snapshot 99 reset volume-statistics 100 restart mc 101 restart sc 102 restore defaults 103 rollback volume 104 scrub disk-groups 106 set advanced-settings 107 set auto-write - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 5
143 set led 144 set network-parameters 145 set ntp-parameters 147 set password 148 set pool 149 set prompt 151 set protocols 152 set schedule 154 171 show chap-records 172 show cli-parameters 173 show configuration 175 show controller-date 176 show controllers 177 show controller- - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 6
show initiators 217 show inquiry 219 show iscsi-parameters 220 show job-parameters (Deprecated 221 show license 222 show maps 224 show network-parameters 227 show ntp-status 229 show pools 230 show pool-statistics 232 show ports 236 show power-supplies 239 show protocols 240 show - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 7
debug-log-parameters 316 disk-groups 320 disk-group-statistics 326 disk-group-statistics-paged 327 disk-hist-statistics 328 disk-statistics 330 drive-parameters 332 drive-summary 333 drives 334 email-parameters 342 enclosure-fru 343 enclosure-list 345 enclosures 346 events 350 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 8
-view-mappings 435 volume-names 436 volume-reservations 437 volumes 438 volume-statistics 442 volume-view 444 volume-view-mappings 445 A Settings changed by restore defaults 446 Glossary 449 Index 458 8 Contents - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 9
Tables 1 Document conventions 12 2 Default usernames and passwords 13 3 XML API elements 17 4 Keyboard shortcuts for command completion, editing, and history 22 5 Size representations in base 2 and base 10 23 6 Decimal (radix) point - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 10
97 volumes properties 438 98 volume-statistics properties 442 99 volume-view properties 444 100 volume-view-mappings properties 445 101 Settings changed by restore defaults 446 10 Tables - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 11
Lenovo Storage S3200/S2200 Getting Started* Lenovo Safety, Support and Warranty* Lenovo Important Notices* Lenovo Storage Product Regulatory Compliance and Safety* Lenovo Storage Rackmount Bracket Kit Installation Lenovo Storage S3200/S2200 Setup Guide Lenovo Storage Manager Guide Lenovo Storage - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 12
Guide Enhancements, known issues, and late-breaking information not included in product documentation Lenovo Storage S3200/S2200 Release Notes * Printed document included in product shipkit. For additional information, contact support.lenovo.com, select Product Support, and navigate to Storage - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 13
about accessing the CLI and obtaining IP values for storage-system management, see your product's Setup Guide. Table 2 Default usernames and passwords Username Password Roles monitor manage !monitor Monitor (view only) !manage Monitor, Manage (view and change) CLI output formats The CLI has - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 14
Using CLI interactively By default the CLI is an interactive application. When you are a user into the CLI. The script uses the command-line parameters specified as the IP address, username, and password. After the user has been logged in, other commands can be sent to the CLI. use Net::Telnet; - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 15
XML API via HTTP. use LWP::UserAgent; use Digest::MD5 qw(md5_hex); use XML::LibXML; # generate MD5 hash using default username/password my $md5_data = "manage_!manage"; my $md5_hash = md5_hex( $md5_data ); print "$md5_hash\n"; # create the URL and send an http GET request $ua = LWP::UserAgent->new - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 16
foreach my $prop ( @props ) { my $name = $prop->getAttribute('name'); print "Property = " . $name . "\n"; if( $name eq 'response' ) { $sessionKey = $prop->textContent; } } print "Session Key = $sessionKey\n"; # Run a sample command to obtain the disks in the system. $url = 'http://10.0.0.2/api/show/ - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 17
Using the XML API The Management Controller provides access for monitoring and management via the Telnet and SSH only one RESPONSE element per issued command. OBJECT In general, an OBJECT element describes a storage-system component such as a disk or a volume. An object has these attributes: • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 18
, parameters, and their values (as shown throughout this guide). For use with the HTTP interface, use a '/' or obtaining the current configuration. Other commands provide configuration data and display one wbi password Abc#1379 • HTTP interface format: create/user/JSmith/interfaces/wbi/password/Abc - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 19
mode. In brief mode, which is disabled by default, returns a subset of attributes of object properties. The oid="2" format="rows"> PTP type="string"> N/A - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 20
number. • A list of disk-group names or serial numbers separated by commas (with no spaces). Not all commands support lists. Example: dg1,"Disk group 1" Specifying pools For virtual storage, you can specify: • A pool by its name or serial number. • A list of pool names or serial numbers separated - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 21
(with no spaces). Not all commands support lists. List example: vd1_v1,"Vol #1" Specifying volume groups For virtual storage, you can specify: • A volume second * represents all initiators in those hosts. Example: TestLab.*.* User password rules • The value is case sensitive. • The value can have - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 22
Command completion, editing, and history The CLI supports command completion, command editing, and command history. When entering commands interactively you can abbreviate their names and keywords. For example, you can enter sho cl - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 23
the controller modules and encompasses all field-replaceable units (FRUs) in the storage system. Each event has one of the following levels, in decreasing . Evaluate the problem and correct it if necessary. • Informational. A configuration or state change occurred, or a problem occurred that the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 24
and users create user, delete user, exit, help, set cli-parameters, set password, set prompt, set user, show cli-parameters, show users Disks, disk groups show versions, shutdown Service utilities clear events, clear expander-status, fail, reset smis-configuration, restore defaults, set debug-log - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 25
3 Alphabetical list of commands This chapter is organized to help you find a command by name. Each command topic includes one or more of the following sections: Description The command's purpose and notes about its usage Minimum role The minimum user role required to use the command Syntax The - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 26
abort scrub Description Aborts a media scrub operation. Minimum role manage Syntax abort scrub [disk-group disk-groups] Parameters disk-group disk-groups Optional. A comma-separated list of the names or serial numbers of the disk - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 27
abort verify Description Aborts a media verify operation. Minimum role manage Syntax abort verify [disk-group disk-groups] Parameters disk-group disk-groups Optional. A comma-separated list of the names or serial numbers of the disk - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 28
of different rotational speed or sector size types (512n, 512e). For virtual storage, a disk group of midline SAS disks will be used in the Archive disk group, simply remove the read cache and re-add it. Minimum role manage Syntax add disk-group disks disks [level raid1|r1|raid5|r5|raid6|r6|raid10 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 29
For disk syntax, see "Command syntax" (page 20). The minimum and maximum numbers of disks supported for each RAID level are: NRAID: 1 RAID 0: 2-16 RAID 1: 2 RAID 3: 3-16 type of disk group to create. • virtual: A disk group for virtual storage. • read-cache: A disk group for use as read cache for a - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 30
. This means that the host must be mapped with the same access, port, and LUN settings to the same volumes or volume groups. Minimum role manage Syntax add host-group-members hosts hosts host-group Parameters hosts hosts A comma-separated list of the names of hosts to add to the specified - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 31
that the initiator must be mapped with the same access, port, and LUN settings to the same volumes or volume groups. Minimum role manage Syntax add host-members initiators initiators host-name Parameters initiators initiators A comma-separated list of the nicknames or IDs of initiators to add to - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 32
group with the same disk type. The system can have 16 global spares. For information about sparing rules, see the "About spares" topic in the Storage Manager Guide. TIP: A disk group can contain a mix of 512-byte native sector size (512n) disks and 512-byte emulated sector size (512e) disks. For - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 33
the volume must be mapped with the same access, port, and LUN settings to the same initiators, hosts, or host groups. Minimum role manage Syntax add volume-group-members volumes volumes volume-group Parameters volumes volumes A comma-separated list of the names or serial numbers of virtual volumes - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 34
use commands in the "See also" section to determine which components have health problems to be resolved. For information about using the SMC or FTP to update firmware, see the Storage Manager Guide. Minimum role manage Syntax check firmware-upgrade-health Output Upgrade Health • Pass: There are no - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 35
Check firmware upgrade health for a system that has problems to be resolved before upgrade. # check firmware-upgrade-health Upgrade Health Fail Condition Detected Risks One or more disks are currently single ported. Data unavailability - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 36
is offline or quarantined could result in data loss. You can clear unwritable cache data for a specified volume or for all volumes. Minimum role manage Syntax clear cache [volume volume] Parameters volume volume Optional. The name or serial number of a specific volume for which to clear unwritable - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 37
loss. If you are uncertain whether to use this command, contact technical support for further assistance. Each disk in a disk group has metadata that that are not leftovers, the disks are not changed. Minimum role manage Syntax clear disk-metadata disks Parameters disks The IDs of the leftover - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 38
clear events Description Clears the event log in controller A, B, or both. For use by or with direction from technical support. Minimum role manage Syntax clear events [a|b|both] Parameters a|b|both Optional. The controller event log to clear. If this parameter is omitted, both event logs are - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 39
for SAS expander lanes. For use by or with direction from technical support. Counters and status can be reset to a good state for all the rescan to complete and then retry the clear operation. Minimum role manage Syntax clear expander-status [enclosure ID] Parameters enclosure ID Optional. The - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 40
back up, the system and disks will be in the Secured, Locked state. Set the system's lock key to restore access to data. Minimum role manage Syntax clear fde-keys [current-passphrase value] Parameters current-passphrase value Optional. If the system is currently secured, you can provide the current - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 41
certificate Description Creates or removes a custom security certificate. The storage system supports use of unique certificates for secure data communications, to authenticate that the expected storage systems are being managed. Use of authentication certificates applies to the HTTPS protocol - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 42
Restore the system-generated certificate and remove the custom certificate. # create certificate restore See also • restart mc • restart sc • show certificate 42 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 43
originator and the recipient (mutual CHAP). For a login request from an iSCSI host to a storage system, the host is the originator and the storage system is the recipient. Minimum role manage Syntax create chap-record name originator-name secret originator-secret [mutual-name recipient-name mutual - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 44
use the set initiator command. Minimum role manage Syntax create host [host-group host-group] ID is an IQN. profile standard|hp-ux Optional. • standard: Default profile. • hp-ux: The host uses Flat Space Addressing. name .com.example:storage.host2.port1, iqn.1992-01.com.example:storage.host2.port2 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 45
See also • set host • set initiator • show host-groups • show initiators create host 45 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 46
Creates a host group that includes specified hosts. You can create a maximum of 32 host groups, each containing a maximum of 256 hosts. Minimum role manage Syntax create host-group hosts hosts host-group Parameters hosts hosts A comma-separated list of the names of hosts to include in the host group - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 47
create schedule Description Schedules a task to run automatically. Minimum role manage Syntax create schedule schedule-specification "specification" task-name task-name schedule-name Parameters schedule-specification "specification" Defines when the task will first run, and optionally - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 48
Create schedule Sched2 that runs Task2 for the first time on March 1, 2014, and on the first weekday of each month, with no expiration. # create schedule schedule-specification "start 2012-03-01 00:01 only first weekday of month" task-name Task2 Sched2 See also • delete schedule • set schedule • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 49
create snapshots Description Creates a snapshot of each specified source volume. For virtual storage, the source volume can be a base volume or a snapshot. Minimum role manage Syntax create snapshots volumes volumes snap-names Parameters volumes volumes A comma-separated list of the names or serial - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 50
disks that are not in a virtual pool. You can use this to disable or suspend spin down during hours of frequent activity. Minimum role Syntax manage To create a task to enable spin down for all disks: create task type EnableDSD name To create a task to disable spin down for all disks - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 51
support SNMPv3 security features such as authentication and encryption. Minimum role manage password password] [precision #] [privacy-password encryption-password] [privacy-type DES|AES|none] [roles roles] [storage-size-base 2|10] [storage-size-precision #] [storage is the default. Operating systems - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 52
is enabled by default. • wbi: Web-browser interface. This is enabled by default. • ftp: FTP interface. • smis: Storage Management Initiative Specification ( use a security encryption protocol. This parameter requires the privacy-password parameter and the authentication-type parameter. • DES: Data - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 53
view but not change system settings. This is the default. • manage: User can view and change system settings. • diagnostic storage-size-base 2|10 Optional. Alias for base. storage-size-precision # Optional. Alias for precision. storage password: ******** Re-enter new password: ******** create user 53 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 54
, using authentication without encryption. # create user interfaces snmptarget authentication-type MD5 trap-host 172.22.4.171 Traps Enter new password: ******** Re-enter new password: ******** See also • delete user • set snmp-parameters • set user • show users 54 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 55
, the hosts must be cooperatively managed, such as by using cluster software. NOTE: You cannot map LUN 0 for a SAS initiator. You can create a maximum of 1024 volumes, but because the supported LUN range is 1-1023 only 1023 volumes can be mapped using default mapping. Using explicit mapping, all - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 56
, the resulting size will be in base 2. If no unit is specified, the default is 512-byte blocks. A value less than 4 MB (3.8 MiB) will be rounded If overcommit is enabled, the size can exceed the physical capacity of the storage pool. To see whether overcommit is enabled, use the show pools command. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 57
create volume-group Description Creates a volume group that includes specified volumes. Minimum role manage Syntax create volume-group volumes volumes volume-group Parameters volumes volumes A comma-separated list of the names of volumes to include in the volume group. A - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 58
, the hosts must be cooperatively managed, such as by using cluster software. NOTE: You cannot map LUN 0 for a SAS initiator. You can create a maximum of 1024 volumes, but because the supported LUN range is 1-1023 only 1023 volumes can be mapped using default mapping. Using explicit mapping, all - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 59
Volumes will be created up to the maximum number supported per disk group. pool pool Optional; required for in base 2. If no unit is specified, the default is 512-byte blocks. If the combined size size can exceed the physical capacity of the storage pool. To see whether overcommit is enabled, - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 60
See also • create volume • delete volumes • map volume • set volume • show maps • show pools • show volume-groups • show volumes • unmap volume 60 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 61
is deleted and their space in the pool is freed for use. For virtual storage, the source volume can be a base volume or a snapshot. The snapshots' deleted, all data in those snapshots will be lost. Minimum role manage Syntax delete all-snapshots volume volume Parameters volume volume The name or - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 62
not CHAP is enabled. CAUTION: Deleting CHAP records may make volumes inaccessible and the data in those volumes unavailable. Minimum role Syntax manage To delete the CHAP record for a specific originator: delete chap-records name originator-name To delete all CHAP records: delete chap-records - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 63
all hosts in those groups. Before using the option to delete all the hosts in the groups, ensure that the hosts are unmapped. Minimum role manage Syntax delete host-groups [delete-hosts] host-groups|all Parameters delete-hosts Optional. Specifies to delete all hosts in the groups. If this parameter - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 64
. Deleting a host does not delete its initiators. Volume maps continue to apply to the initiators in the host that is deleted. Minimum role manage Syntax delete hosts hosts|all Parameters hosts|all Specifies either: • A comma-separated list of the names of hosts to delete. A name that includes - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 65
by its ID. Minimum role manage Syntax delete initiator-nickname initiator|all Parameters initiator|all Specifies either: • The nickname or ID of the initiator to delete. A value that includes a space must be enclosed in double quotes. • all: Deletes all manually created initiators and nicknames of - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 66
all the data it contains. For virtual storage, a pool can contain multiple disk groups again (to clear those disks). Minimum role manage Syntax delete pools [prompt yes|no] pools Cancel the command. If this parameter is omitted, you must manually reply to prompts. pools A comma-separated list of the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 67
to delete both, or no to delete only the schedule. Minimum role manage Syntax delete schedule [prompt yes|no] schedule Parameters prompt yes|no Optional. • no: Cancel the command. If this parameter is omitted, you must manually reply to prompts. schedule The name of the schedule to delete. Examples - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 68
snapshot's schedules are also deleted. CAUTION: When a snapshot is deleted, all data in the snapshot will be lost. Minimum role manage Syntax delete snapshot [force] snapshots Parameters force Optional. Overrides priority protection and forces the specified snapshot to be deleted. snapshots A comma - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 69
Reply yes to delete both, or no to cancel the command. Minimum role manage Syntax delete task [prompt yes|no] task Parameters prompt yes|no Optional. . • no: Cancel the command. If this parameter is omitted, you must manually reply to prompts. task The name of the task to delete. Examples Delete task - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 70
Deletes a user account. Except for the user you are logged in as, you can delete any user, including the default users. However, the system requires at least one CLI user with the manage role to exist. When a user is deleted, any sessions associated with that user name are terminated. Minimum role - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 71
, ensure that the volumes are unmapped. If any volume is mapped, the command will fail and no changes will be made. Minimum role manage Syntax delete volume-groups [delete-volumes] volume-groups|all Parameters delete-volumes Optional. Specifies to delete all volumes in the groups. If this parameter - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 72
delete volumes Description Deletes specified volumes. CAUTION: Deleting a volume will delete all data it contains, and its schedules. Minimum role manage Syntax delete volumes volumes Parameters volumes A comma-separated list of the names or serial numbers of the volumes to delete. A name that - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 73
CLI trust command. If a disk group is manually dequarantined and does not have enough disks to It is recommended that you contact technical support for assistance in determining if the recovery for these events, see the Event Descriptions Reference Guide. Examples of when quarantine can occur are: • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 74
). • The dequarantine command is used to manually dequarantine the disk group. If the inaccessible have restarted after a power failure. If these problems are found and then fixed, the disk group again (to clear those disks). Minimum role manage Syntax dequarantine disk-group disk-group Parameters - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 75
Examples After determining that virtual disk group DG1 is quarantined, remove it from quarantine and re-check its status. # show disk-groups Name ... Status DG1 ... QTDN ... (RAID 6 quarantined with a down disk dequarantine disk-group DG1 Info: Disk group DG1 was dequarantined. (DG1) ... # show - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 76
exit Description Log off and exit the CLI session. Minimum role monitor Syntax exit 76 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 77
see whether overcommit is enabled, use the show pools command. Minimum role manage Syntax expand volume size size[B|KB|MB|GB|TB|KiB|MiB|GiB|TiB unit, the resulting size will be in base 2. If no unit is specified, the default is 512-byte blocks. volume The name or serial number of the volume to expand - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 78
command causes the crash by issuing an internal kill command to the Storage Controller in the partner controller module. This might be helpful to the failed controller, potentially causing data loss. Minimum role manage Syntax fail controller a|b Parameters controller a|b Specifies whether to - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 79
, the hosts must be cooperatively managed, such as by using cluster software. NOTE: You cannot map LUN 0 for a SAS initiator. You can create a maximum of 1024 volumes, but because the supported LUN range is 1-1023 only 1023 volumes can be mapped using default mapping. Using explicit mapping, all - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 80
the second volume, and so on. The lun parameter is ignored if access is set to no-access. If the lun parameter is omitted, the default LUN is presented. ports ports Optional. The controller host ports to use for the mapping. Any unspecified ports become unmapped. All specified ports must be - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 81
or a list of basetypes separated by commas (with no spaces) to specify the objects for which to show metadata. For names and descriptions of supported basetypes, see "XML API basetype properties" (page 291). Examples Show all metadata for objects returned by the show disks command: # meta drives See - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 82
The remote host's IP address in dotted decimal form. count count Optional. The number of packets to send. The default is 4 packets. Use a small count because the command cannot be interrupted. The default is 4 packets. Examples Send two packets to the remote computer at 10.134.50.6. # ping 10.134.50 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 83
when the system is in an abnormal state, perhaps due to a configuration problem, and you need to remove all reservations for specified volumes and return to the volumes whose reservations will be released. Minimum role manage Syntax release volume all|volumes Parameters all|volumes Specifies all - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 84
you must delete it again (to clear those disks). Minimum role manage Syntax remove disk-groups [prompt yes|no] disk-groups Parameters prompt proceed. • no: Cancel the command. If this parameter is omitted, you must manually reply to prompts. disk-groups A comma-separated list of the names or serial - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 85
from a host group. You cannot remove all hosts from a group. At least one host must remain. The hosts are ungrouped but not deleted. Minimum role manage Syntax remove host-group-members hosts hosts host-group Parameters hosts hosts A comma-separated list of the names of hosts to remove from the host - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 86
cannot remove all initiators from a host. At least one initiator must remain. The initiators are ungrouped but not deleted. Minimum role manage Syntax remove host-members initiators initiators host-name Parameters initiators initiators A comma-separated list of the names of initiators to remove from - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 87
remove spares Description Removes specified spares. Minimum role manage Syntax remove spares disks Parameters disks The IDs of the spares to remove. For disk syntax, see "Command syntax" (page 20). Examples Remove global spare 1. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 88
group. You cannot remove all volumes from a group. At least one volume must remain. The volumes are ungrouped but not deleted. Minimum role manage Syntax remove volume-group-members volumes volume-IDs volume-group Parameters volumes volume-IDs A comma-separated list of the names or serial numbers of - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 89
to the controller enclosure. A manual rescan is not needed after inserting or removing disks because the controllers automatically detect these changes. When disks are inserted they are detected after a short delay, which allows the disks to spin up Minimum role manage Syntax rescan Examples Scan - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 90
will continue to be stored every quarter hour. Minimum role manage Syntax reset all-statistics [historical] [prompt yes|no] Parameters the historical parameter is specified and the prompt parameter is omitted, you must manually reply to the prompt. If the historical parameter is omitted, the prompt - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 91
. This command resets all controller statistics except Power On Time. To reset this, restart or power cycle a controller. Minimum role manage Syntax reset controller-statistics [a|b|both] Parameters a|b|both Optional. Specifies whether to reset statistics for controller A, B, or both. If this - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 92
) • Number of block reassignments • Number of bad blocks found To reset other disk statistics, use the reset disk-statistics command. Minimum role manage Syntax reset disk-error-statistics [disks] Parameters disks Optional. The IDs of the disks for which to reset statistics. For disk syntax, see - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 93
-group-statistics Description Clears resettable performance statistics for linear disk groups only, and resets timestamps for those statistics. Minimum role manage Syntax reset disk-group-statistics disk-groups Parameters disk-groups Optional. A comma-separated list of the names or serial numbers - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 94
but not disk error statistics. To reset these, use the reset disk-error-statistics command. Lifetime statistics are not resettable. Minimum role manage Syntax reset disk-statistics Examples Reset statistics for all disks. # reset disk-statistics See also • reset all-statistics • reset controller - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 95
. For FC, you can reset a single port. For an FC host port configured to use FC-AL (loop) topology, a reset issues a loop initialization primitive a COMINIT/COMRESET sequence and might reset other ports. Minimum role manage Syntax reset host-link ports ports Parameters ports ports A controller host - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 96
reset host-port-statistics Description Resets performance statistics for controller host ports. Minimum role manage Syntax reset host-port-statistics [ports ports] Parameters ports ports Optional. The controller ID and port number of ports for which to reset statistics. For - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 97
reset pool-statistics Description Clears resettable performance statistics for virtual pools, and resets timestamps for those statistics. Minimum role manage Syntax reset pool-statistics [pool] Parameters pool Optional. The name or serial number of the virtual pool for which to reset statistics. A - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 98
of the SMI-S service to default settings. After running this command, any hosts registered via SMI-S will need to be registered again. Messages are displayed when the SMI-S configuration is reset and SMI-S is restarted. Minimum role manage Syntax reset smis-configuration [a|b|both] [prompt yes - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 99
exists prior to issuing this command will be lost. Minimum role manage Syntax reset snapshot [prompt yes|no] snapshot Parameters prompt yes proceed. • no: Cancel the command. If this parameter is omitted, you must manually reply to prompts. snapshot The name or serial number of the snapshot to reset. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 100
reset volume-statistics Description Resets performance statistics for all or specified volumes. Minimum role manage Syntax reset volume-statistics [volumes] Parameters volumes Optional. A comma-separated list of the names or serial numbers of the volumes for which to reset statistics. A - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 101
is lost until it successfully restarts. If the restart fails, the partner Management Controller remains active with full ownership of operations and configuration information. Minimum role manage Syntax restart mc [a|b|both] [noprompt] Parameters a|b|both Optional. The controller module containing - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 102
operations and flushing the write cache to disk, and then the Storage Controller restarts. Restarting a Storage Controller restarts the corresponding Management Controller. CAUTION: • Depending on the mapping configuration, restarting one Storage Controller may cause loss of access to data. • If you - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 103
to restore host access to volumes. Minimum role manage Syntax restore defaults [noprompt] [prompt yes|no] Parameters noprompt is omitted, you must manually reply to prompts. Examples Restore the controllers' default configuration. # restore defaults See also • reset smis-configuration • restart mc • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 104
parent volume as it currently exists before performing a rollback. NOTE: For virtual storage, you cannot exclude modified write data in a snapshot from being used in a read-only and use it for the rollback. Minimum role manage Syntax rollback volume [prompt yes|no] snapshot snapshot volume - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 105
See also • show snapshots • show volumes rollback volume 105 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 106
disk groups to find and fix disk errors. For virtual storage, this command acts on disks in a disk group but and specifies whether errors were found and whether user action is required. Minimum role manage Syntax scrub disk-groups disk-groups Parameters disk-groups A comma-separated list of the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 107
advanced-settings Description Sets advanced system configuration parameters. Minimum role manage Syntax set advanced-settings [auto-stall detection in the background and automatically perform recovery actions. This is the default. auto-write-back enabled|disabled|on|off Optional. Sets whether the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 108
default default default default storage system will poll each enclosure's Enclosure Management Processor (EMP) for status changes, from 5 to 3600 seconds. The default is the default. • storage system's write-back cache setting. • disabled or off: Host control of caching is disabled. This is the default - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 109
storage system to a log collection system to avoid losing diagnostic data. • disabled or off: The managed logs feature is disabled. This is the default. • enabled or on: The managed default. • enabled or on: The power-supply failure trigger is enabled. single-controller Optional; for use by a service - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 110
inactivity shown by the spin-down-delay parameter. • disabled or off: Drive spin down for available disks and global spares is disabled. This is the default. Disabling spin down will set the spin-down delay to 0. • enabled or on: Drive spin down for available disks and global spares is enabled. If - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 111
logs. # set advanced-settings managed-logs enabled Disable auto stall recovery. # set advanced-settings auto-stall-recovery disabled See also • add spares • remove spares • scrub disk-groups • show advanced-settings - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 112
until you find the optimal size for your application. Minimum role manage Syntax set cache-parameters [optimization standard|no-mirror] [read-ahead- calculate the optimum read-ahead size for the current workload. This is the default. • stripe: Sets the read-ahead size to one stripe. The controllers - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 113
while it is being written to disk can increase storage device speed during sequential reads. • write-back or operations and throughput. This is the default. • write-through or wt: Write with low or no fault tolerance. You can configure the write policy to automatically change from write-back - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 114
permitted whether or not CHAP is enabled. Minimum role manage Syntax set chap-record name originator-name [secret originator-secret iqn.1991-05.com.microsoft:myhost.domain mutual-name iqn.1995-03.com.acme:01.storage.00c0ffd6000a mutual-secret ABCdef123456(2012-01-21 11:54:33) See also • create chap - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 115
be overridden by using this command. Minimum role manage Syntax set cli-parameters [base 2|10] [ 2|10 Optional. Sets the base for entry and display of storage-space sizes: • 2: Sizes are shown as powers of 2, window resizes. This is the default. • api: Supports scripting by displaying command output - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 116
precision # Optional. Sets the number of decimal places (1-10) for display of storage-space sizes. The default is 1. storage-size-base 2|10 Optional. Alias for base. storage-size-precision # Optional. Alias for precision. storage-size-units auto|MB|GB|TB Optional. Alias for units. temperature-scale - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 117
For scripting, display brief XML output in api-embed format and disable paging. # set cli-parameters api-embed pager off brief on Set the CLI to show output in console format. # set cli-parameters console See also • show cli-parameters set cli-parameters 117 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 118
. Minimum role Syntax manage To set the date and time manually: set controller-date jan|feb|mar|apr|may|jun|jul|aug|sep|oct|nov|dec day hh:mm:ss year To set the date and time manually by specifying a timestamp: set controller-date timestamp timestamp timezone +|-hh[:mm] To configure use of NTP - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 119
will be in UTC, unless you also specify the timezone parameter. Examples Manually set the system time and date to 1:45 PM on September 22, 2011. # set controller -date sep 22 13:45:0 2011 Manually set the system date and time to 4:30:50 PM on November 2, 2011 by - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 120
debug messages. Enabled by default. • mui: Internal service interface debug messages. Enabled by default. • ps: Paged storage. Enabled by default. • raid: RAID debug messages. Enabled by default. • rcm: Removable-component manager debug messages. Disabled by default. • res2: Internal debug messages - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 121
the set advanced-settings command's spin-down parameter. Drive spin down is not applicable to disks in virtual pools. Minimum role manage Syntax set disk [noprompt] repurpose disk Parameters noprompt Optional. Suppresses confirmation prompts. Specifying this parameter allows the command to proceed - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 122
set disk-group Description Changes parameters for a specified disk group. Minimum role manage Syntax set disk-group [name new-name] disk-group Parameters name new-name Optional. A new name for the disk group. A name that includes a space must - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 123
may be delayed while the disks are spinning back up. Minimum role manage Syntax set disk-parameters [smart enabled|disabled|on|off|detect-only] Drive spin down for available disks and global spares is disabled. This is the default. Disabling spin down will set the spin-down delay to 0. • enabled or - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 124
Examples Enable SMART and drive spin down, and set the spin-down delay to 10 minutes. # set disk-parameters smart on spin-down on spin-down-delay 10 See also • show disk-parameters 124 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 125
log files to managed-logs email notifications that are sent to the log collection system. This option is disabled by default. notification-level crit cannot include a space or: " , < > \ For example: Storage-1. server server The IP address of the SMTP mail server to use for the email messages. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 126
Examples Set the system to send an email from [email protected] to both [email protected] and [email protected] when a non-Informational event occurs, and to send an email with attached logs to [email protected] when logs need to be transferred. # set email-parameters server 10 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 127
enclosures command and in event-log entries related to enclosures. Minimum role manage Syntax set enclosure [name new-name] [location location] [rack-number parameters for enclosure 1. # set enclosure 1 name Storage-5 location Lab rack-number 9 rack-position 3 See also • show enclosures set - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 128
counters for a specific PHY exceed the built-in thresholds, the PHY is disabled to maintain storage system operation. While troubleshooting a storage system problem, a service technician can use this command to temporarily disable fault isolation for a specific Expander Controller in a specific - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 129
or enables a specific PHY. For use by or with direction from technical support. CAUTION: Disabling PHYs can prevent access to system devices, which can cause data unavailability or data loss. Minimum role manage Syntax set expander-phy controller a|b|both enabled|disabled|on|off [encl enclosure-ID - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 130
expander PHY. • sc: Storage Controller PHY. • sc-0: Storage Controller primary PHY. • sc-1: Storage Controller alternate PHY. • sca-p: Storage Controller A primary PHY. • scb-p: Storage Controller B primary PHY. • sca-a: Storage Controller A alternate PHY. • scb-a: Storage Controller B alternate PHY - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 131
into the system from a different secure system. Minimum role manage Syntax set fde-import-key [noprompt] passphrase value Parameters noprompt command to proceed without user interaction. passphrase value A customer-supplied password associated with securing the system. Input rules: • The value is - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 132
the passphrase, you could be locked out of your data. Minimum role manage Syntax set fde-lock-key [current-passphrase value] [noprompt] passphrase value to proceed without user interaction. passphrase value A customer-supplied password associated with securing the system. Input rules: • The value - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 133
be repurposed, where each disk is secure erased. Minimum role manage Syntax set fde-state [noprompt] [repurpose] [secure passphrase become secured, using the specified FDE system passphrase, which must have been previously configured. A value that includes a space must be enclosed in double quotes. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 134
optionally the profile of the host and the initiators it contains. Minimum role manage Syntax set host [name new-name] [profile standard|hp-ux] host-name be enclosed in double quotes profile standard|hp-ux Optional. • standard: Default profile. • hp-ux: The host uses Flat Space Addressing. CAUTION: - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 135
set host-group Description Sets the name of a host group. Minimum role manage Syntax set host-group name new-name host-group Parameters name new-name A new name for the host group. Input rules: • The value is case - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 136
S2200 SAS controller, host ports can be configured to use fan-out SAS cables or standard SAS cables. Host ports can be configured as FC or iSCSI ports. FC ports support Minimum role Syntax manage To set FC set host-parameters [controller a|b|both] [default-router address] [gateway address] [ip - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 137
S2200 default router for the port IP address. This parameter requires the ports parameter. gateway address Optional. For iSCSI, the port gateway address. This parameter requires the ports parameter. ip address Optional. For iSCSI, the port IP address. Ensure that each iSCSI host port in the storage - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 138
. If this parameter is omitted, you must manually reply to prompts. speed 4g|8g|16g|auto you need to specify a mutually supported speed for more than two FC devices default router for port A1. # set host-parameters ports A1 iscsi-ip-version ipv6 ip ::8576:246a default-router ::0a0a:1 On an S2200 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 139
See also • restart mc • restart sc • set host-port-mode • set iscsi-parameters • show ports set host-parameters 139 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 140
I/O, restart both controllers, and log event 236. After the controllers have restarted, you can use the set host-parameters command to configure the individual ports. Minimum role manage Syntax set host-port-mode [FC|iSCSI|FC-and-iSCSI] [noprompt] Parameters FC|iSCSI|FC-and-iSCSI Sets the port mode - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 141
the name of an initiator and optionally its profile. Minimum role manage Syntax set initiator [id initiator] [nickname name] [profile standard| must be enclosed in double quotes profile standard|hp-ux Optional. • standard: Default profile. • hp-ux: The host uses Flat Space Addressing. CAUTION: - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 142
access from connected hosts. Minimum role manage Syntax set iscsi-parameters [chap enabled Storage Name Service server, which provides name-to-IP-address mapping. Disabled by default. The default address is all zeroes. jumbo-frame enabled|disabled|on|off Optional. Enables or disables support for - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 143
Examples For a storage system using IPv4 addressing whose host ports are connected to different subnets, enable CHAP, specify the IP address of the iSNS server on each subnet, - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 144
set led Description Changes the state of the identification LED on a specified device. LEDs are described in the Setup Guide. Minimum role Syntax manage To set a disk LED: set led disk ID enable|disable|on|off To set the LEDs for an enclosure and its I/O modules: set led [controller a|b] - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 145
manually set static IP values for each controller, or you can specify that IP values should be set automatically for both controllers through communication with a Dynamic Host Configuration Protocol (DHCP) server. Each controller has the following factory-default Minimum role manage Syntax set - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 146
default. • 6: Not supported. NOTE: IPv6 for controller module network ports is not supported storage system to respond when a ping to a broadcast address is issued on the system's subnet. The default is Disabled. Examples Use DHCP to set network port IP values. # set network-parameters dhcp Manually - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 147
manually set system date and time parameters by using the set controller-date command. You must specify at least one of the optional parameters for the command to succeed. Minimum role manage with the server. This is disabled by default. ntpaddress IP-address Optional. The network address - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 148
, this command affects the logged-in user's password. Examples Change the password for the default user, manage. # set password manage Enter new password: ******** Re-enter new password: ******** Change the password for user JDoe. # set password JDoe password Abcd%1234 See also • show users 148 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 149
controls whether the pool uses thin provisioning. Minimum role manage Syntax set pool [low-threshold #%] [middle-threshold #%] can add more enclosures to the system. This is the default. • disabled or off: The pool will use full provisioning storage pool for which to change settings. set pool 149 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 150
Examples For pool A, set the low threshold to 30%. # set pool low-threshold 30% A For pool B, disable overcommit. # set pool overcommit off B See also • delete pools • show pools 150 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 151
set prompt Description Sets the prompt for the current CLI session. This setting does not persist beyond the current session. Minimum role manage Syntax set prompt prompt Parameters prompt The new prompt. Input rules: • The value is case sensitive. • The value can have a maximum of 16 characters. • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 152
|on|off Optional. Enables or disables the in-band SCSI Enclosure Management Services interface. This is enabled by default. smis enabled|disabled|on|off Optional. Enables or disables the secure Storage Management Initiative Specification interface (SMI-S) interface. This option allows SMI-S clients - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 153
|disabled|on|off Optional. Enables or disables the standard CLI. This is enabled by default. usmis enabled|disabled|on|off Optional. Enables or disables the unsecure Storage Management Initiative Specification (SMI-S) interface. This option allows SMI-S clients to communicate with each controller - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 154
the existing one. You must specify at least one of the optional parameters for the command to succeed. Minimum role manage Syntax set schedule [schedule-specification "specification"] [task-name task-name] schedule-name Parameters schedule-specification "specification" Optional. Defines when the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 155
notifications for all events. • none: All events are excluded from trap notification and traps are disabled. This is the default. However, Critical events and managed-logs events 400-402 are sent regardless of the notification setting. read-community string Optional. Sets a community string for - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 156
Examples Enable Critical events only, specify a trap host, and set the community string for read-only access. # set snmp-parameters enable crit add-trap-host 172.22.4.171 read-community public See also • set protocols • show snmp-parameters • test (with the snmp parameter) 156 Alphabetical list of - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 157
by the syslog of a specified host computer. Syslog is a protocol for sending event messages across an IP network to a logging server. Minimum role manage Syntax set syslog-parameters [host-ip IP-address] [host-port port-number] notification-level crit|error|warn|info|none Parameters host-ip IP - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 158
are included in system debug logs for reference by service personnel. When using the SMC, the system name be enclosed in double quotes. Minimum role manage Syntax set system [contact value] [info the system is used for or how it is configured. location value Optional. The location of the system. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 159
one CLI user with the manage role to exist. A user with the manage role can change any parameter except password password] [precision #] [privacy-password encryption-password] [privacy-type DES|AES|none] [roles roles] [session-preferences] [storage-size-base 2|10] [storage-size-precision #] [storage - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 160
by default. • wbi: Web-browser interface (the SMC). This is enabled by default. • ftp: FTP interface. • smis: Storage Management Initiative Chinese-traditional|zh-t Optional. The display language. The default is English. password password Optional in console format; required for XML API format. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 161
view but not change system settings. This is the default. • manage: User can view and change system settings. • storage-size-base 2|10 Optional. Alias for base. storage-size-precision # Optional. Alias for precision. storage password for user JDoe. # set user JDoe password Abcd%1234 set user 161 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 162
Change the authentication type for SNMPv3 user Traps. # set user Traps authentication-type MD5 password Snmp%Trap See also • set password • show users 162 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 163
set volume Description Changes parameters for a volume. CAUTION: Applying new volume parameters may disrupt access from connected hosts. Minimum role manage Syntax set volume [access read-write|rw|read-only|ro] [identifying-information description] [name new-name] volume Parameters access read-write - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 164
set volume-group Description Sets the name of a volume group. Minimum role manage Syntax set volume-group name new-name volume-group Parameters name new-name A new name for the volume group. Input rules: • The value is case - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 165
for new disks added to the system. This is the default. • Disabled: SMART is disabled for all disks in the system and will be disabled for new disks added to the system. Dynamic Spare Configuration Shows whether the storage system will automatically use a compatible disk as a spare to replace - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 166
Enclosure Polling Rate Shows the interval in seconds at which the storage system will poll each enclosure's Enclosure Management Processor (EMP) for status changes, from 5 to 3600 seconds. The default is 5 seconds. Host Control of Caching Shows whether hosts are allowed to use the SCSI MODE SELECT - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 167
• Disabled: Background disk scrub is disabled. This is the default. • Enabled: Background disk scrub is enabled. Managed Logs Shows whether the managed logs feature is enabled, which allows log files to be transferred from the storage system to a log collection system to avoid losing diagnostic data - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 168
will constantly perform auto stall detection in the background and automatically perform recovery actions. This is the default. Examples Show advanced system-configuration settings. # show advanced-settings Basetypes • advanced-settings-table • status See also • set advanced-settings show auto-write - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 169
is met, the cache policy for all volumes changes to write-through, overriding the volume-specific settings. When the problem is corrected, the cache policy reverts to the value configured for each individual volume. • Enabled: Write-back. This is the normal state. • Disabled: Write-through. • Not up - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 170
for applications that read and write small files in random order, such as transaction-based and database update applications. This is the default. • no-mirror: When this mode is enabled, each controller stops mirroring its cache metadata to the partner controller. This improves write I/O response - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 171
show certificate Description Shows the status of the system's security certificate. Minimum role manage Syntax show certificate [a|b|both] Parameters Output a|b|both Optional. Specifies whether to show information for controller A, B, or both. If this parameter is omitted, information is shown - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 172
, show the CHAP record for a specific host initiator. # show chap-records name iqn.1991-05.com.microsoft:myhost.domain As a user with the manage role, show the CHAP record for a specific host initiator. # show chap-records name iqn.1991-05.com.microsoft:myhost.domain show-secrets Basetypes • chap - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 173
and adjusts content to window resizes. This is the default. • api: Supports scripting by displaying command output in XML. All objects output, shows all attributes of object properties. This is the default. Base The base for entry and display of storage-space sizes: • 2: Sizes are shown as powers of - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 174
Units The unit for display of storage-space sizes: • Auto: Sizes are shown in units determined by the system. This is the default. • MB: Sizes are shown in • Celsius: Temperatures are shown in degrees Celsius. This is the default. Examples Show current CLI settings. # show cli-parameters Basetypes • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 175
input, enable or disable the pager parameter of the set cli-parameters command. Minimum role monitor Syntax Output show configuration • System information from show system • Controller information from show controllers • Controller firmware and hardware version information from show versions - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 176
show controller-date Description Shows the system's current date and time. Minimum role monitor Syntax show controller-date Output Controller Date Date and time in the format year-month-day hour:minutes:seconds. Time-Zone Offset The system's time zone as an offset in hours and minutes from - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 177
Version Controller module hardware version. CPLD Version Complex Programmable Logic Device firmware version. MAC Address Controller network port MAC address. WWNN Storage system World Wide Node Name (WWNN). IP Address Controller network port IP address. IP Subnet Mask Controller network port IP - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 178
controller. • Enabled: PHY fault isolation is enabled. This is the default. • Disabled: PHY fault isolation is disabled. Controller Redundancy Mode Shows are active using ULP (Unified LUN Presentation). Data for volumes configured to use write-back cache is automatically mirrored between the two - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 179
operational. • Down: This controller is not operational. • Unknown: Status information is not available. Examples Show controller information. # show controllers Basetypes • controllers • status See also • show configuration • show frus show controllers 179 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 180
show controller-statistics Description Shows live performance statistics for controller modules. For controller performance statistics, the system samples live data every 15 seconds. Statistics shown only in XML API output are described in "XML API basetype properties" (page 291). Minimum role - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 181
Examples Show statistics for controller A. # show controller-statistics a Basetypes • controller-statistics • status See also • reset all-statistics • reset controller-statistics show controller-statistics 181 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 182
messages. Enabled by default. • emp: Enclosure Management Processor debug messages. Enabled by default. • capi: Internal Configuration API debug messages. Enabled by default. • mui: Internal service interface debug messages. Enabled by default. • bkcfg: Internal configuration debug messages. Enabled - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 183
show disk-groups Description Shows information about disk groups. The command will show information for all disk groups by default, or you can use parameters to filter the output. Minimum role monitor Syntax show disk-groups [pool pool] [disk-groups] Parameters pool pool Optional. Specifies - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 184
disk group contains a mix of 512n and 512e disks. This is supported, but for consistent and predictable performance, do not mix disks of different . Spin Down • Disabled: DSD is disabled for the disk group. This is the default. • Enabled - all spinning: DSD is enabled for the disk group. • Partial - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 185
, which uses midline spinning SAS disks ( - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 186
show disk-group-statistics Description Shows live performance statistics for disk groups. The command will show information for all disk groups by default, or you can use parameters to filter the output. For disk-group performance statistics, the system samples live data every 30 seconds. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 187
Unmapped per Minute The number of 4-MB pages that host systems have unmapped per minute, through use of the SCSI UNMAP command, to free storage space as a result of deleting files or formatting volumes on the host. Examples Show live performance statistics for all disk groups. # show disk-group - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 188
and will be enabled for new disks added to the system. This is the default. • Disabled: SMART is disabled for all disks in the system and will be spin down for available disks and global spares is disabled. This is the default. • Enabled: Drive spin down for available disks and global spares is - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 189
show disks Description Shows information about all disks or disk slots in the storage system. If no parameter is specified, the command shows information for all installed disks. NOTE: In console format, to aid reading, disks are sorted to - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 190
data access, preventing its use. • FDE Protocol Failure: A temporary state that can occur while the system is securing the disk. Health Shown by default or by the detail or fde or perf parameter. • OK • Degraded • Fault • N/A • Unknown Health Reason Shown by the detail parameter. See Reason, below - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 191
Shown by the encl parameter. The model number of the disk. Pool Shown by default. The name of the pool that contains the disk. Pool Name Shown by the stored in disk metadata and is updated in 30-minute increments. Reason Shown by default or by the detail or fde or perf parameter. If Health is not OK - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 192
system and will be enabled for new disks added to the system. This is the default. • Disabled: SMART is disabled for all disks in the system and will be disabled for new disks added to the system. Speed (kr/min) Shown by default or by the detail or fde or perf parameter. The speed of a spinning - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 193
disk is present but the system is having communication problems with the disk LED processor. For disk and Shown by default or by the detail parameter. • Performance: The disk is in the highest storage tier, which Some 6-Gbit/s disks might not consistently support a 6-Gbit/s transfer rate. If this - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 194
is locked to data access, or the disk is from an unsupported vendor.VIRTUAL POOL: The disk is a member of a disk group in a storage pool. Vendor Shown by default and by any parameter except temp. The vendor of the disk. Examples Show disk information. # show disks Show disk-slot information. # show - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 195
[time-range "date/time-range"] disks Parameters all Optional. Specifies to show the full set of performance metrics. If this parameter is omitted, the default set of performance metrics will be shown. count number-of-data-samples Optional. Specifies the number of data samples to display, from 1 to - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 196
Output Live Location The disk location in the format disk_enclosure-ID.slot-number. Serial Number The serial number of the disk. Pwr Hrs The total number of hours that the disk has been powered on since it was manufactured. This value is stored in disk metadata and is updated in 30-minute increments - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 197
parameter. The average number of pending read and write operations being serviced since the last sampling time. This value represents periods of activity of times the disk did not respond; number of attempts by the storage system to spin-up the disk; media errors generated by the disk as specified - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 198
Show historical statistics from a specified date and time range for disk 1.5. # show disk-statistics 1.5 historical time-range "start 2011-12-05 4:40 PM end 2011-12-05 5:00 PM" Show all samples of historical statistics for disk 1.5. # show disk-statistics 1.5 historical all Basetypes • disk- - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 199
info: Sends notifications for all events. • none: Disables email notification and clears the settings. This is the default. This parameter does not apply to managed-logs notifications. Email Address (1-3) Shows up to three email addresses for recipients of event notifications. Log Destination Shows - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 200
Description Shows information about the enclosures in the storage system. Full detail available in XML API output EMP controller-ID BUS:ID Rev The channel ID and firmware revision of the Enclosure Management Processor in each controller's Expander Controller. Midplane Type • 2U24-6Gv2: Midplane for - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 201
Action If Health is not OK, this field shows recommended actions to take to resolve the health issue. Examples Show information about all enclosures in the system. # show enclosures Basetypes • enclosures • status See also • set enclosure • show sensor-status show enclosures 201 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 202
Description Shows events logged by each controller in the storage system. A separate set of event numbers is . For more information, see "Resources for diagnosing and resolving problems" in the Event Descriptions Reference Guide. Minimum role monitor Syntax show events [a|b|both|error] [detail - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 203
Lists events as described in the Output section, below. This is the default. • yes: Shows events in tabular format, with columns for event ID integrity. Evaluate the problem and correct it if necessary. • INFORMATIONAL: A configuration or state change occurred, or a problem occurred that the system - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 204
See also • clear events • set snmp-parameters • show snmp-parameters 204 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 205
direction from technical support. For each Storage Controller PHY. • SC-0: Storage Controller primary PHY. • SC-1: Storage Controller alternate PHY. • SCA-A: Storage Controller A alternate PHY. • SCA-P: Storage Controller A primary PHY. • SCB-A: Storage Controller B alternate PHY. • SCB-P: Storage - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 206
PHY disabled by a SES control page as a result of action by a Storage Controller or user. • Not ready: PHY is enabled but not ready. Appears problem exists such as a broken connector. • Drive removed: PHY disabled because drive slot is empty. • Unused - disabled by default: PHY is disabled by default - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 207
show fans Description Shows information about each fan in the storage system. Minimum role monitor Syntax show fans Output Name The fan name in the form Fan loc:position-PSU power-supply-ID. The position is - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 208
Examples Show about all fans in the system. # show fans Basetypes • fan • status See also • show power-supplies 208 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 209
state Description Shows Full Disk Encryption information for the storage system. Minimum role monitor Syntax show fde-state ID is displayed. Import Key ID The previous or import lock ID is displayed. FDE Configuration Time If the system is secured, the time at which the current lock ID was set - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 210
show frus Description Shows FRU (field-replaceable unit) information for the storage system. Some information is for use by service technicians. Minimum role monitor Syntax Output show frus FRU fields: Name • CHASSIS_MIDPLANE: Chassis and midplane circuit board • RAID_IOM: Controller module • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 211
IOM MEMORY CARD SLOT: Memory card slot in controller module A. • LOWER IOM MEMORY CARD SLOT: Memory card slot in controller module B. Configuration SN The configuration serial number. FRU Status • Absent: The FRU is not present. • Fault: The FRU's health is Degraded or Fault. • Invalid Data: The - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 212
command will show information for all host groups (and hosts) by default, or you can use parameters to filter the output. Minimum role and its entry was automatically created. • No: The initiator was manually created. Mapped Shows whether the initiator is explicitly mapped to any volumes - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 213
ID • For an FC initiator, its WWPN. • For a SAS initiator, its WWPN. • For an iSCSI initiator, its node name (typically the IQN). Examples Show information about all host groups. # show host-groups Show information about host groups HGroup1 and HGroup3. # show host-groups groups HGroup1,HGroup3 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 214
show host-phy-statistics Description Shows diagnostic information relating to SAS controller physical channels, known as PHY lanes, for each host port. This command shows PHY status information for each host port found in an enclosure. Each controller in an enclosure may have multiple host ports. A - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 215
The amount of data written since these statistics were last reset or since the controller was restarted. Queue Depth The number of pending I/O operations being serviced. show host-port-statistics 215 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 216
I/O Resp Time The average response time in microseconds for read and write operations, calculated over the interval since these statistics were last requested or reset. Read Resp Time The average response time in microseconds for all read operations, calculated over the interval since these - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 217
its entry was automatically created. • No: The initiator was manually created. Mapped Shows whether the initiator is explicitly mapped to • No: No volumes are explicitly mapped to the initiator. Profile • Standard: Default profile. • HP-UX: The host uses Flat Space Addressing. Host Type The host - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 218
Show information about initiators in host Host1 only. # show initiators hosts Host1 Basetypes • initiator • status See also • delete initiator-nickname • set initiator • show host-groups (with the hosts parameter) 218 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 219
. Minimum role monitor Syntax show inquiry Output • Product vendor name, product ID, and vendor ID • Management Controller firmware version and loader version • Storage Controller firmware version and loader version • Controller module serial number • Media Access Control (MAC) address • Network - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 220
or disabled. • Enabled: Jumbo-frame support is enabled. • Disabled: Jumbo-frame support is disabled. This is the default. iSNS Shows whether support for Internet Storage Name Service (iSNS) is enabled or disabled. • Enabled: iSNS support is enabled. • Disabled: iSNS support is disabled. This is the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 221
show job-parameters (Deprecated) Use show advanced-settings. show job-parameters (Deprecated) 221 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 222
license Description Shows the status of licensed features in the storage system. Minimum role monitor Syntax show license Output License enabled and doesn't expire. VSS Shows whether the VSS (Volume Shadow Copy Service) Hardware Provider is enabled or disabled. VSS Expires • Never. Always enabled - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 223
Basetypes • license • status show license 223 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 224
maps [all] [initiator] [IDs] Parameters all Optional. Shows mappings of all access types: read-write, read-only, no-access, and not-mapped (default mappings). If this parameter is omitted, mappings of type not-mapped are not shown. initiator Optional. Shows mapping information by initiator. If - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 225
all other initiators. Ports • The controller host ports to which the mapping applies. • Blank if not mapped or mapped as no-access. Profile • Standard: Default profile. • HP-UX: The host uses Flat Space Addressing. Serial Number The serial number of the volume group or volume. Volume • For a volume - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 226
Show mapping information for all initiators. # show maps initiator Show mappings for volume group VGroup1 and ungrouped volume v2. # show maps VGroup1.*,v2 Basetypes • initiator-view • host-group-view • host-view-mappings • volume-group-view • volume-group-view-mappings • volume-view • volume-view- - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 227
. Subnet Mask The network port IP subnet mask. MAC Address The controller's unique Media Access Control address. Addressing Mode • Manual: Network settings are set manually (statically). • DHCP: DHCP is used to set network parameters. Link Speed • Unknown: For a system operating in Single Controller - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 228
Basetypes • network-parameters • status See also • set network-parameters 228 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 229
(NTP) in the system. Minimum role monitor Syntax show ntp-status Output NTP Status • activated: NTP is enabled. • deactivated: NTP is disabled. This is the default. NTP Server Address • The current NTP server IP address if NTP is enabled. • The last-set NTP server IP address if NTP was enabled and - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 230
The low threshold for page allocation as a percentage of pool capacity. When this threshold is exceeded, event 462 will be logged with Informational severity. The default is 25%. 230 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 231
pool is overcommitted, the event will have Warning severity. The default is 50%. High Thresh The high threshold for page allocation as Mixed: The pool contains a mix of 512n and 512e disks. This is supported, but for consistent and predictable performance, do not mix disks of different rotational - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 232
] [time-range "date/time-range"] Parameters all Optional. Specifies to show the full set of performance metrics. If this parameter is omitted, the default set of performance metrics will be shown. count number-of-data-samples Optional. Specifies the number of data samples to display, from 1 to 100 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 233
Pages Unmapped per Minute The number of 4-MB pages that host systems have unmapped per minute, through use of the SCSI UNMAP command, to free storage space as a result of deleting files or formatting volumes on the host. Time Since Reset The amount of time, in seconds, since these statistics were - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 234
Write Resp Time Shown by the all parameter. The average response time, in microseconds, for write operations since the last sampling time. Historical For a pool: Pool The name of the pool. Total I/Os The total number of read and write operations since the last sampling time. Reads Shown by the all - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 235
Allocated Pages The number of 4-MB pages allocated to volumes in the tier. Page Moves In The number of pages moved into this tier from a different tier. Page Moves Out The number of pages moved out of this tier to other tiers. Page Rebalances The number of pages moved between disks in this tier to - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 236
down. • Disconnected: Either no I/O link is detected or the port is not cabled. Speed(A) • Actual link speed in Gbit/s. • Blank if not applicable. Speed(C) Configured host-port link speed. Not shown for SAS. • FC: Auto, 16Gb, 8Gb, or 4Gb (Gbit/s) • iSCSI: Auto • Blank if not applicable Health • OK - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 237
to take to resolve the health issue. Topo (C) FC and SAS only. Configured topology. Lanes Expected SAS only. If the detail parameter is specified, this For IPv4, subnet mask for assigned IP address. Default Router iSCSI only. For IPv6, default router for assigned IP address. Link-Local Address iSCSI - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 238
specified, this field shows the link speeds that the SFP supports. Ports/Conn S2200 SAS controller module only. The number of virtual host ports per specified, this field shows the link length (in meters) that is supported by the SFP while operating in compliance with applicable standards for the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 239
show power-supplies Description Shows information about each power supply in the storage system. Minimum role monitor Syntax show power-supplies Output Encl The ID of the enclosure that contains the power supply. Serial Number The serial number - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 240
SMI-S provider via HTTP port 5989. The default is Enabled. Unsecure Storage Management Initiative Specification (SMI-S 5988) Shows whether the . The default is Disabled. Service Debug Shows whether the Telnet debug port is enabled or disabled. The default is Disabled. In-band SES Management (SES) - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 241
Basetypes • security-communications-protocols • status See also • set protocols • show cli-parameters show protocols 241 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 242
volumes, and mappings. The command will show information for all associations by default, or you can use parameters to filter the output. This command port syntax, see "Command syntax" (page 20). This command does not support the use of hyphens to indicate a range of ports. volumes volumes Optional. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 243
no-access. Access Type of host access to the volume: • read-write: The host has read and write access to the volume. This is the default. • read-only: The host has read access to the volume. • no-access: The host is denied access to the volume. • not-mapped: The host is - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 244
Nickname Host nickname, or blank if not set or for all other hosts Profile • Standard: Default profile. • HP-UX: The host uses Flat Space Addressing. Examples Show provisioning for the system. # show provisioning Basetypes • provisioning • status See also • show disk-groups • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 245
are active using ULP (Unified LUN Presentation). Data for volumes configured to use write-back cache is automatically mirrored between the two or not installed. Other MC Status The operational status of the Management Controller in the partner controller. This is not factored into system - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 246
show refresh-counters Description In XML API format only, shows when the data represented by the basetype was last updated. The value 0 means the data has never been updated and is not cached. A value other than 0 is a timestamp indicating that the data has been updated. If the value has changed - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 247
show sas-link-health Description Shows the condition of SAS expansion-port connections. Minimum role monitor Syntax show sas-link-health Output Encl The enclosure ID. Ctlr The ID of the controller module or expansion module. Name • Out Port: Egress (expansion) port in a controller module or an - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 248
show schedules Description Shows information about all task schedules. Minimum role monitor Syntax show schedules [schedule-name] Output schedule-name Optional. Shows information about the specified schedule only. A name that includes a space must be enclosed in double quotes. If this parameter - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 249
See also • create schedule • delete schedule • set schedule • show tasks show schedules 249 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 250
error ranges for temperature and voltage are specified in the Setup Guide. Minimum role monitor Syntax show sensor-status Output Encl The enclosure This typically occurs during controller startup. • Unrecoverable: The enclosure management processor (EMP) cannot communicate with the sensor. • Unknown - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 251
Storage Controller is active or shut down. Minimum role monitor Syntax show shutdown-status Output Controller A • up (active) • down (shut down or killed) • not installed Controller B • up (active) • down (shut down or killed) • not installed Other MC Status The operational status of the Management - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 252
show snapshots Description Shows information about snapshots. The command will show information for all snapshots by default, or you can use parameters to filter the output. Minimum role monitor Syntax show snapshots [pool pool] [volume volume] Parameters pool pool Optional. Specifies the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 253
Snaps The number of child snapshots (snapshots taken of this snapshot). TreeSnaps The number of snapshots taken of the base volume and its children. This count includes the base volume and all snapshots that share the base volume as their root. Snap-Pool • Blank for virtual snapshots. Snap Data The - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 254
the monitor role and is shown in clear text for users having the manage role. SNMP write community The community string for write access. The value the monitor role and is shown in clear text for users having the manage role. Examples Show SNMP notification settings. # show snmp-parameters Basetypes - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 255
show syslog-parameters Description Shows syslog notification parameters for events and managed logs. Minimum role monitor Syntax show syslog-parameters Output Syslog Host IP The IP address of the remote syslog server to use for the notifications. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 256
the storage system. If the system's health is not OK, each unhealthy component is listed with information to help you resolve the health problem. description of what the system is used for or how it is configured. The default is Uninitialized Info. Midplane Serial Number The serial number of the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 257
the health state. Other MC Status The operational status of the Management Controller in the partner controller. This is not factored into system partner firmware update is running on the system, or is idle. Supported Locales Supported display languages: Arabic (ar), Portuguese, (br), English (en), - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 258
logical limits of the storage system, see the system configuration limits topic in is managed in the controller firmware. ULP appears to the host as an active-active storage system Host Groups The number of host groups that the system supports. Maximum Hosts per Host Group The maximum number of - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 259
Examples Show settings and configuration limits for the storage system. # show system-parameters Basetypes • system-parameters-table • status See also • show system show system-parameters 259 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 260
show tasks Description Shows information about tasks. Minimum role monitor Syntax show tasks [task-name] Output task-name Optional. Shows information about the specified task only. If this parameter is omitted, information is shown for all tasks. For an EnableDSD task: Task Name The name of - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 261
For a DisableDSD task: Task Name The name of the task. Task Type DisableDSD Status • Uninitialized: The task is not yet ready to run. • Ready: The task is ready to run. • Active: The task is running. • Error: The task has an error. • Invalid: The task is invalid. • Complete: The task is complete. • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 262
show tiers Description Shows information about tiers. Minimum role monitor Syntax show tiers tier performance|standard|archive|readcache|all Parameters Output tier performance|standard|archive|readcache|all Specifies the tier for which to show information. Pool The name of the pool. Tier The - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 263
for tiers. The command will show information for all tiers by default, or you can use parameters to filter the output. For tier systems have unmapped per minute, through use of the SCSI UNMAP command, to free storage space as a result of deleting files or formatting volumes on the host. Time Since - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 264
Data Written The amount of data written since these statistics were last reset or since the controller was restarted. Bps The data transfer rate, in bytes per second, calculated over the interval since these statistics were last requested or reset. This value will be zero if it has not been - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 265
show unwritable-cache Description Shows the percentage of unwritable data in the system. This data has not been written to disk because it is associated with a volume that no longer exists or whose disks are not online. If the data is needed, the volume's disks must be brought online. If the data is - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 266
password] [user] Parameters show-snmp-password Optional. Minimum role: manage. For SNMPv3 users, this parameter shows Password and Privacy Password values in clear text for reference when configuring users in the corresponding management default. SMI-S • x: The user can access the Storage Management - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 267
Encryption Standard. • none: No encryption. This is the default. Password The user password. For a standard user the password is represented by eight asterisks. For an SNMPv3 user this is the authentication password. Privacy Password The encryption password for an SNMPv3 user whose privacy type is - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 268
show versions Description Shows firmware and hardware version information for each controller module. Minimum role monitor Syntax show versions [detail] Parameters detail Optional. Shows information about the versions of firmware and hardware in each controller module. If this parameter is omitted, - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 269
show volume-groups Description Shows information about specified volume groups or all volume groups Minimum role monitor Syntax show volume-groups [volume-groups] Parameters Output volume-groups Optional. A comma-separated list of the names of volume groups for which to show information. If - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 270
Reason If Health is not OK, this field shows the reason for the health state. Action If Health is not OK, this field shows recommended actions to take to resolve the health issue. Examples Show information about all volume groups. # show volume-groups Show information about volume groups VGroup1 and - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 271
show volume-names Description Shows volume names and serial numbers. Minimum role monitor Syntax show volume-names [volumes] Parameters Output volumes Optional. A comma-separated list of the names or serial numbers of the volumes for which to show information. A name that includes a space must - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 272
reservations (PGR) mechanism enables application clients on multiple hosts to control access to a storage volume, and limits access by other hosts. Each host must be registered with the storage system in order to establish a persistent reservation for a volume, thereby becoming a reservation holder - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 273
Reservation Type • Write Exclusive: Write commands are only allowed for a single reservation holder. • Exclusive Access: Certain access (read, write) commands are only allowed for a single reservation holder. • Write Exclusive - Registrants Only: Write commands are only allowed for registered hosts. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 274
for applications that read and write small files in random order, such as transaction-based and database update applications. This is the default. • no-mirror: When this mode is enabled, each controller stops mirroring its cache metadata to the partner controller. This improves write I/O response - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 275
is the preferred setting for a fault-tolerant environment because it improves the performance of write operations and throughput. This is the default. • write-through: Write-through caching significantly impacts performance by waiting for data to be completely written to disk before signaling the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 276
See also • create volume • delete volumes • expand volume • set volume • show disk-groups • show maps • show pools 276 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 277
show volume-statistics Description Shows live performance statistics for all or specified volumes. For each volume these statistics quantify I/O operations between hosts and the volume. For example, each time a host writes to a volume's cache, the volume's statistics are adjusted. For volume - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 278
% Standard The percentage of volume capacity occupied by data in the Standard tier. % Archive The percentage of volume capacity occupied by data in the Archive tier. % RC The percentage of read-cache capacity that is occupied. Reset Time The date and time, in the format year-month-day hour:minutes: - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 279
's data. Perform a shut down before removing a controller module or powering down the system. Minimum role manage Syntax shutdown [a|b|both] Parameters a|b|both Optional. Specifies to shut down the Storage Controller in controller A, B, or both. If this parameter is omitted, the command affects the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 280
: Specify one of these options to send notification for one of the Storage Controller's four crash logs. • ecdebug: Specify this option to send notifications by every interface that is configured to receive them. # test notification Test receipt of the managed-logs notification that the SC log - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 281
corruption-the command will fail. You may then seek assistance from technical support or run the command with a special parameter to acknowledge the risk in performing it. CAUTION: 1. Do not use the trust command when the storage system is unstable. For example, if there are many power or topology- - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 282
single-controller configuration, disconnect the host-port cables. In a dual-controller configuration: a. If this happens you can either: • Contact Support for further assistance. This is recommended. • Proceed enable background scrub operations. Minimum role manage Syntax trust [enable|disable] [disk - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 283
all good disks in the disk group each time there is a change in the disk configuration of the disk group, such as when a disk is detected to have failed or the other disk group members. This value can be used as a guide to decide which disks to physically remove before doing the trust operation to - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 284
12:49) # trust disk-group data_1 Error: The trust operation failed because the disk group has an insufficient number of in-sync disks. - Please contact Support for further assistance. (2013-09-17 04:13:13) Trust a disk group which has out-of-sync or partially reconstructed disks that would be needed - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 285
cases cause data corruption. Because of the risk of data corruption, it is recommended that you continue the trust operation only with the supervision of Support personnel. If you are ready to continue, enter "continue" at the prompt or enter "abort" to abort the operation and leave the disk group - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 286
After enabling trust, disable it if you decide not to run trust disk-group. # trust disable Success: Command completed successfully. - Trust is disabled. (2013-09-17 17:40:01) See also • show disk-groups • verify disk-groups 286 Alphabetical list of commands - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 287
from a simulated failure performed with the fail command (which requires the manage role). If you attempt to unfail a controller that is operating, the command will have no effect. Minimum role manage Syntax unfail controller Examples From controller A, unfail the partner controller. # unfail - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 288
longer be able to access the volume's data. Minimum role manage Syntax unmap volume [host hosts] [initiator initiators|hosts|host , mapping changes apply to all initiators that are not explicitly mapped (the default mapping). volumes|volume-groups A comma-separated list of volumes or volume groups - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 289
can find and fix media errors for any RAID level. Minimum role manage Syntax verify disk-groups [fix yes|no] disk-groups Parameters fix yes fix parity mismatches by making parity match the data in all cases. The default is no. disk-groups A comma-separated list of the names or serial numbers - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 290
Verifies FC host-port link paths between controller A and controller B. This command is not applicable to a system with SAS controller modules. Minimum role manage Syntax verify link [link-type FC|iSCSI|ALL] Parameters Output link-type FC|iSCSI|ALL Optional. Specifies the type of host-port links - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 291
4 XML API basetype properties Chapter 3 describes command output that is shown in console format. This chapter describes the basetype properties that CLI commands display in XML API format, and is organized to help you find a basetype by name. This chapter excludes basetypes that are for internal - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 292
scrub finishing and starting again, from 0 to 360 hours. The default is 24 hours. string Shows whether component firmware versions are monitored system and will be enabled for new disks added to the system. This is the default. • Disabled: SMART is disabled for all disks in the system and will be - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 293
which the storage system will poll each enclosure's Enclosure Management Processor (EMP) for status changes, from 5 to 3600 seconds. The default is 5 values. • 0: Immediate • 1: Flush to Disk string Not supported. uint32 string uint32 string uint32 Numeric equivalents for independent-cache values - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 294
policy will change from write-back to write-through when a fan fails. • Disabled: The fan failure trigger is disabled. This is the default. • Enabled: The fan failure trigger is enabled. uint32 Numeric equivalents for fan-failure values. • 0: Disabled • 1: Enabled string Shows whether the system - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 295
enabled, which allows log files to be transferred from the storage system to a log-collection system to avoid losing diagnostic data as logs fill. • Disabled: The managed logs feature is disabled. This is the default. • Enabled: The managed logs feature is enabled. uint32 Numeric equivalents for - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 296
stallrecovery auto-stallrecoverynumeric Type Description string Not supported. uint32 Not supported. string uint32 Shows whether the auto is disabled. • Enabled: Auto stall recovery is enabled. This is the default. Numeric equivalents for auto-stall-recovery values. • 0: Disabled • 1: Enabled - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 297
for applications that read and write small files in random order, such as transaction-based and database update applications. This is the default. • no-mirror: When this mode is enabled, each controller stops mirroring its cache metadata to the partner controller. This improves write I/O response - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 298
Table 9 cache-parameter properties (continued) Name read-aheadsize-numeric Type Description uint32 Numeric equivalents for read-ahead-size values. • -2: Stripe • -1: Adaptive • 0: Disabled • 524288: 512 KB • 1048576: 1 MB • 2097152: 2 MB • 4194304: 4 MB • 8388608: 8 MB • 16777216: 16 MB • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 299
mode, also called the cache redundancy mode. • Active-Active ULP: Both controllers are active using ULP (Unified LUN Presentation). Data for volumes configured to use write-back cache is automatically mirrored between the two controllers to provide fault tolerance. • Single Controller: There is only - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 300
when a controller is restarting or the certificate replacement process is still in process. uint32 Numeric equivalents for certificate-status values. • 0: Default • 1: Customer-supplied string The date and time, in the format year-month-day hour:minutes:seconds, when the certificate was created - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 301
chap-records This basetype is used by show chap-records. Table 12 chap-records properties Name initiator-name initiatorsecret oname osecret Type Description string The originator name. string The secret that the recipient uses to authenticate the originator. string For mutual CHAP, the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 302
content and adjusts content to window resizes. This is the default. • api: Supports scripting by displaying command output in XML. All objects are . This is the default. uint32 Numeric equivalents for brief-mode values. • 0: Disabled • 1: Enabled uint8 Alias for storage-size-base. string - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 303
usually show size in base 10. Memory (RAM and ROM) size is always shown in base 2. uint8 Number of decimal places (1-10) for display of storage-space sizes. The default is 1. string Unit for display of storage-space sizes. • Auto: Lets the system determine the proper unit for a size. This is the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 304
type user-typenumeric username management-mode managementmode-numeric Type Description uint32 Numeric equivalents for storage-size-units values. The logged-in user's experience level. • Novice • Standard (the default) • Advanced • Diagnostic uint32 Numeric equivalents for user-type values. • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 305
code-load-readiness This basetype is used by check firmware-upgrade-health. Table 14 code-load-readiness properties Name overall-health overall-healthnumeric code-loadreadinessreasons Type Description string • Pass: There are no risks to performing firmware upgrade. • Fail: At least one - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 306
failure-risksnumeric Type Description string The condition that was detected. string Numeric equivalents for readiness-reason values. string string The problems that are likely to result if you do not resolve the conditions before performing a firmware upgrade. Numeric equivalents for failure - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 307
compact-flash This basetype is used by show controllers. Table 16 compact-flash properties Name durable-id controller-id controller-idnumeric name status status-numeric cache-flush cache-flushnumeric health health-numeric health-reason healthrecommendation Type Description string • Ctlr A CF: - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 308
is met, the cache policy for all volumes changes to write-through, overriding the volume-specific settings. When the problem is corrected, the cache policy reverts to the value configured for each individual volume. • Enabled: Write-back. This is the normal state. • Disabled: Write-through. • Not up - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 309
Table 17 controller-cache-parameters properties (continued) Name cache-flush cache-flushnumeric Type Description string • Enabled: If the controller loses power, it will automatically write cache data to the CompactFlash card. Cache flush is normally enabled, but is temporarily disabled during - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 310
string string string uint32 uint32 Complex Programmable Logic Device (CPLD) firmware version. Controller network port MAC address. Storage system World Wide Node Name (WWNN). The configured network port IP version. • 4: IPv4 Controller network port IP address. Controller network port IP subnet mask - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 311
are prevented from using the SCSI MODE SELECT command to change the storage system's write-back cache setting. • No: Hosts are permitted overriding the volume-specific settings. When the problem is corrected, the cache policy reverts to the value configured for each individual volume. • write-back: - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 312
Table 18 controllers properties (continued) Name write-policynumeric description part-number revision dash-level fru-shortname mfg-date mfg-datenumeric mfg-location mfg-vendor-id locator-led locator-lednumeric health health-numeric health-reason healthrecommendation position positionnumeric Type - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 313
controller. • Enabled: PHY fault isolation is enabled. This is the default. • Disabled: PHY fault isolation is disabled. uint32 Numeric equivalents for are active using ULP (Unified LUN Presentation). Data for volumes configured to use write-back cache is automatically mirrored between the two - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 314
controller-statistics This basetype is used by show controller-statistics. Table 19 controller-statistics properties Name durable-id cpu-load power-on-time write-cacheused bytes-persecond bytes-persecond-numeric iops number-of-reads read-cache-hits read-cachemisses number-ofwrites write-cachehits - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 315
Table 19 controller-statistics properties (continued) Name start-sampletime start-sampletime-numeric stop-sampletime stop-sampletime-numeric total-power-onhours Type Description string Date and time, in the format year-month-day hour:minutes:seconds, when sampling started for the iops and bytes- - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 316
0: Off • 1: On string Shows whether disk interface debug messages are enabled for inclusion in the Storage Controller debug log. • Off: Disabled. • On: Enabled. This is the default. uint32 Numeric equivalents for disk values. • 0: Off • 1: On string Shows whether internal memory debug messages - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 317
equivalents for misc values. • 0: Off • 1: On string Shows whether removable-component manager debug messages are enabled for inclusion in the Storage Controller debug log. • Off: Disabled. This is the default. • On: Enabled. uint32 Numeric equivalents for rcm values. • 0: Off • 1: On string - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 318
Shows whether Internal Configuration API debug messages are enabled for inclusion in the Storage Controller debug log. • Off: Disabled. • On: Enabled. This is the default. uint32 Numeric equivalents for capi values. • 0: Off • 1: On string Shows whether internal service interface debug messages - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 319
whether Internal Configuration API tracing messages are enabled for inclusion in the Storage Controller debug log. • Off: Disabled. This is the default. • whether Reservation Manager debug messages are enabled for inclusion in the Storage Controller debug log. • Off: Disabled. This is the default. • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 320
basetype is used by show configuration, show disk-groups, and show pools. Table 21 disk-groups properties Name name size size-numeric freespace freespacenumeric raw-size raw-sizenumeric storage-type storage-typenumeric pool pool-serialnumber storage-tier storage-tiernumeric total-pages allocated - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 321
Table 21 disk-groups properties (continued) Name owner owner-numeric preferred-owner preferredowner-numeric raidtype raidtypenumeric diskcount sparecount chunksize Type Description string Either the preferred owner during normal operation or the partner controller when the preferred owner is - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 322
Table 21 disk-groups properties (continued) Name status status-numeric lun min-drive-size min-drive-sizenumeric create-date create-datenumeric Type Description string • CRIT: Critical. The disk group is online but isn't fault tolerant because some of its disks are down. • DMGD: Damaged. The disk - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 323
Table 21 disk-groups properties (continued) Name cache-readahead cache-readahead-numeric cache-flushperiod read-aheadenabled read-aheadenabled-numeric write-backenabled write-backenabled-numeric job-running current-job current-jobnumeric current-jobcompletion Type string uint64 uint32 string - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 324
and midline SAS disks. Numeric equivalents for array-drive-type values. • 1: MIX • 4: SAS • 8: sSAS • 11: SAS MDL • false: The current job must be manually aborted before you can delete the disk group. • true: The current job will automatically abort if you delete the disk group. Numeric equivalents - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 325
may or may not be aligned with physical block boundaries. • Mixed: The disk group contains a mix of 512n and 512e disks. This is supported, but for consistent and predictable performance, do not mix disks of different rotational speed or sector size types (512n, 512e). string Numeric equivalents - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 326
a user or by a controller restart. uint32 The amount of time, in milliseconds, since this set of statistics was last sampled by the Storage Controller. uint64 Number of read operations since these statistics were last reset or since the controller was restarted. uint64 Number of write operations - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 327
zeroes for data). uint32 The number of 4-MB pages that host systems have unmapped per minute, through use of the SCSI UNMAP command, to free storage space as a result of deleting files or formatting volumes on the host. disk-group-statistics-paged 327 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 328
operations last sampling time. uint64 Unformatted write-bytes-per-second value. uint64 Average number of pending read and write operations being serviced since the last sampling time. This value represents periods of activity only and excludes periods of inactivity. uint64 Average response time - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 329
of times the disk did not respond; number of attempts by the storage system to spin-up the disk; media errors generated by the disk as specified by its manufacturer; non-media errors (generated by the storage system, or by the disk and not categorized as media errors); number - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 330
these statistics were last reset or since the controller was restarted. Unformatted data-written value. uint32 Number of pending I/O operations currently being serviced. uint64 The amount of data read from the disk in its lifetime. uint64 Unformatted lifetime-data-read value. uint64 The amount of - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 331
disk did not respond. uint32 For port 1, the number of attempts by the storage system to spin up the disk. uint32 uint32 For port 1, the number of uint32 For port 2, the number of pending I/O operations currently being serviced. uint32 For port 2, the number of SMART events recorded. uint32 For - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 332
and will be enabled for new disks added to the system. This is the default. • Disabled: SMART is disabled for all disks in the system and will spin down for available disks and global spares is disabled. This is the default. • Enabled: Drive spin down for available disks and global spares is enabled - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 333
drive-summary This basetype is used by show disk-statistics when the historical parameter is specified. Table 27 drive-summary properties Name durable-id serial-number disk-histstatistics Type Description string Disk ID in the form disk_enclosure-number.disk-number. string Disk serial number. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 334
drives This basetype is used by show configuration and show disks. Table 28 drives properties Name durable-id enclosure-id drawer-id slot location port scsi-id blocks serial-number vendor model revision - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 335
to data access, or the disk is from a unsupported vendor. • • VIRTUAL POOL: The disk is a member of a disk group in a storage pool. usage-numeric uint32 Numeric equivalents for usage values. • 0: AVAIL • 3: GLOBAL SP • 5: LEFTOVR • 7: FAILED • 8: UNUSABLE • 9: VIRTUAL POOL job-running string - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 336
Table 28 drives properties (continued) Name job-runningnumeric Type Description uint32 Numeric equivalents for job-running values. • 0: None • 2: INIT • 3: RCON • 4: VRFY • 6: VRSC • 7: DRSC • 9: VREMV • 12: VPREP • 13: VDRAIN • 14: VRECV state current-jobcompletion blink locator-led locator- - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 337
data transfer rate in Gbit/s. It is normal behavior for the rate to vary. • 1.5 • 3.0 • 6.0 Some 6-Gbit/s disks might not consistently support a 6-Gbit/s transfer rate. If this happens, the controller automatically adjusts transfers to those disks to 3 Gbit/s, increasing reliability and reducing - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 338
copyback-statenumeric virtual-diskserial disk-group storage-poolname storage-tier storage-tiernumeric Type Description string Disk status . • Warning: The disk is present but the system is having communication problems with the disk LED processor. For disk and midplane types where this processor - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 339
Table 28 drives properties (continued) Name ssd-life-left ssd-life-leftnumeric led-status led-statusnumeric disk-dsd-count spun-down number-of-ios total-datatransferred total-datatransferrednumeric avg-rsp-time fde-state Type Description string • 100%-0%: For an SSD, this value shows the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 340
sensor is present but status is not available. Numeric equivalents for temperature-status values. • 1: OK • 2: Critical • 3: Warning • other: Unknown Not supported. Not supported. unit32 string uint32 The total number of hours that the disk has been powered on since it was manufactured. This value - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 341
Table 28 drives properties (continued) Name health-reason healthrecommendation Type Description string If Health is not OK, the reason for the health state. string If Health is not OK, the recommended actions to take to resolve the health issue. drives 341 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 342
Critical events. • info: Sends notifications for all events. • none: Disables email notification. This is the default. This parameter does not apply to managed-logs notifications. uint32 Numeric equivalents for email-notification-filter values. • 8: crit • 4: error • 2: warn • 1: info • 0: none - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 343
• UPPER IOM MEMORY CARD SLOT: Memory card slot in controller module A. • LOWER IOM MEMORY CARD SLOT: Memory card slot in controller module B. string Configuration serial number. string string • Absent: The FRU is not present. • Fault: The FRU's health is Degraded or Fault. • Invalid Data: The FRU - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 344
Table 30 enclosure-fru properties (continued) Name originalpartnumber originalrevision enclosure-id Type Description string For a power supply module, the original manufacturer part number. Otherwise, N/A. string For a power supply module, the original manufacturer hardware revision. Otherwise, - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 345
enclosure-list This basetype is used by show configuration, and by show disks when the encl drive spin down feature. • Warning: The disk is present but the system is having communication problems with the disk LED processor. For disk and midplane types where this processor also controls power to - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 346
enclosures This basetype is used by show configuration and show enclosures. Table 32 enclosures properties Name durable-id enclosure-id enclosure-wwn name type type-numeric location rack-number rack-position number-ofcoolingselements - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 347
Table 32 enclosures properties (continued) Name fru-location part-number mfg-date mfg-datenumeric mfg-location description revision dash-level emp-a-rev emp-b-rev rows columns slots locator-led locator-lednumeric driveorientation driveorientationnumeric enclosurearrangement - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 348
Table 32 enclosures properties (continued) Name emp-a-ch-id-rev emp-b emp-b-ch-id-rev midplane-type midplane-typenumeric midplane-rev enclosure-power pcie2-capable pcie2-capablenumeric health health-numeric health-reason healthrecommendation unhealthycomponent controllers Type Description string - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 349
Table 32 enclosures properties (continued) Name power-supplies fan-details Type Description Embedded; see power-supplies. Embedded; see fan. enclosures 349 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 350
For event-code descriptions, see the Event Descriptions Reference Guide. string Event ID. string Controller model. string Controller serial integrity. Evaluate the problem and correct it if necessary. • INFORMATIONAL: A configuration or state change occurred, or a problem occurred that the system - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 351
occurred that may affect system stability but not data integrity. Evaluate the problem and correct it if necessary. • INFORMATIONAL: A configuration or state change occurred, or a problem occurred that the system corrected. No action is required. • RESOLVED: A condition that caused an event to - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 352
expander-ports This basetype is used by show sas-link-health. Table 35 expander-ports properties Name durable-id enclosure-id controller controllernumeric sas-port-type sas-port-typenumeric sas-port-index name name-numeric status status-numeric health Type Description string Expander port ID. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 353
Table 35 expander-ports properties (continued) Name health-numeric health-reason healthrecommendation Type Description uint32 Numeric equivalents for health values. • 0: OK • 1: Degraded • 2: Fault • 3: Unknown • 4: N/A string If Health is not OK, the reason for the health state. string If - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 354
. • 4: The fan FRU is not installed. • 8: The fan status cannot be determined. • 16: The fan is requested to be on (not off). This is the default status and represents normal operation. • 17: Fan has failed. • 18: Fan is off. • 19: Fan has failed and is off. • 24: Fan status is unknown - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 355
Table 36 fan properties (continued) Name status-numeric speed position positionnumeric serial-number fw-revision hw-revision locator-led locator-lednumeric health health-numeric health-reason healthrecommendation Type Description uint32 Numeric equivalents for status values. • 0: Up • 1: Error - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 356
sfp-presentnumeric sfp-vendor sfp-part-number sfp-revision sfp-supportedspeeds Type Description string Configured topology. • Loop: Fibre Channel arbitrated loop (public or private). • PTP . string The SFP revision. string The link speeds that the SFP supports. 356 XML API basetype properties - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 357
fde-state This basetype is used by show fde-state. Table 38 fde-state properties Name Type Description fde-securitystatus string Shows whether the system is secured or unsecured: • Unsecured: The system has not been secured with a passphrase. • Secured: The system has been secured with a - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 358
host This basetype is used by show host-groups. Table 39 host properties Name durable-id name serial-number member-count host-group group-key initiator Type Description string Host ID. string The name of the host. string The serial number of the host. uint32 The number of initiators in the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 359
host-group This basetype is used by show host-groups. Table 40 host-group properties Name durable-id name serial-number member-count host Type Description string Host group ID. string The name of the host group. string The serial number of the host group. uint32 The number of hosts in the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 360
host-group-view This basetype is used by show maps when the initiator parameter is specified. Table 41 host-group-view properties Name durable-id serial-number group-name host-viewmappings Type Description string Host group ID. string The serial number of the host group. string The name of - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 361
last reset or since the controller was restarted. uint64 Unformatted data-written value. uint32 The number of pending I/O operations currently being serviced. uint32 Average response time in microseconds for read and write operations, calculated over the interval since these statistics were last - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 362
discovered and its entry was automatically created. • No: The host entry was manually created. string • Yes: At least one volume is explicitly mapped to the No: No volumes are explicitly mapped to the host. string • Standard: Default profile. • HP-UX: The host uses Flat Space Addressing. string • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 363
SAS host port WWN, or iSCSI host initiator node name (typically the IQN). string User-defined name of the host port, or blank. string • Standard: Default profile. • HP-UX: The host uses Flat Space Addressing. Embedded; see host-view-mappings. host-view 363 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 364
host-view-mappings This basetype is used by show maps when the initiator parameter is specified, and show host-maps (Deprecated). Table 45 host-view-mappings properties Name volume-name volume-serial lun access access-numeric ports Type Description string Volume name. string Volume serial - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 365
No volumes are explicitly mapped to the initiator. string • Standard: Default profile. • HP-UX: The host uses Flat Space Addressing. string its host interface type: FC; iSCSI; SAS. • If the host entry was manually created: Undefined. uint32 Numeric equivalents of host-bus-type values. • 6: FC • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 366
, its WWPN. • For a SAS initiator, its WWPN. • For an iSCSI initiator, its node name (typically the IQN). string The nickname of the initiator. string • Standard: Default profile. • HP-UX: The host uses Flat Space Addressing. Embedded; see host-view-mappings. 366 XML API basetype properties - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 367
serial-number mac-address ip-address nvram-defaults Type Description string Management Controller firmware version. string Management Controller loader firmware version. string Storage Controller firmware version. string Storage Controller loader firmware version. string Controller serial - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 368
, as viewed from the back of the enclosure. • Left • Right • Top • Bottom Numeric equivalents for position values. • 0: Left • 1: Right • 2: Top • 3: Bottom Configuration serial number. string uint32 Shows whether the automatic disabling of SAS expander PHYs having high error counts is enabled or - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 369
Table 49 io-modules properties (continued) Name locator-led locator-lednumeric status status-numeric health health-numeric health-reason healthrecommendation unhealthycomponent enclosure-id Type Description string Shows the state of the locator LED on an expansion module. • Off • On uint32 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 370
for jumbo-frames values. • 0: Disabled • 1: Enabled string Shows whether support for Internet Storage Name Service (iSNS) is enabled. • Enabled: iSNS is enabled. • Disabled: iSNS is disabled. This is the default. uint32 Numeric equivalents for isns values. • 0: Disabled • 1: Enabled string - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 371
string For IPv4, subnet mask for assigned IP address. string For IPv6, default router for the assigned IP address. string For IPv6, the link-local , if supported, or No Support. string The SFP's Ethernet compliance code, if supported, or No Support. string Shows whether the SFP supports active or - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 372
Never: License doesn't expire. Numeric equivalents for max-snapshots-expiry values. • 0: Never Shows whether the capability to create and manage virtual pools is enabled or disabled. • Disabled: Virtualization is disabled. • Enabled: Virtualization is enabled. Numeric equivalents for virtualization - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 373
: VSS is disabled. • Enabled: VSS is enabled. Numeric equivalents for vss values. • 0: Disabled • 1: Enabled Shows when the VSS (Volume Shadow Copy Service) Hardware Provider will expire. • Never: Always enabled and doesn't expire. Numeric equivalents for vss-expiry values. • 0: Never license 373 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 374
Table 52 license properties (continued) Name dsd dsd-numeric dsd-expiry dsd-expirynumeric sra sra-numeric sra-expiry sra-expirynumeric Type Description string Shows whether the Drive Spin Down (DSD) feature is enabled. • Disabled: DSD is disabled. • Enabled: DSD is enabled. uint32 Numeric - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 375
theSMC Save Logs panel. string Contact's phone number, if specified in the SMC Save Logs panel. string Comments describing the problem and specifying the date and time when the problem occurred, if specified in the SMC Save Logs panel. uint32 For internal use only. string Date and time, in the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 376
Description Controller network port ID in the form mgmtport_controller-ID. The configured network port IP version. • 4: IPv4 Controller network port IP port IP subnet mask Controller network port MAC address. • Manual: Network settings are set manually (statically). • DHCP: DHCP is used to set - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 377
Table 54 network-parameters properties (continued) Name health-numeric health-reason healthrecommendation ping-broadcast ping-broadcastnumeric Type Description uint32 Numeric equivalents for health values. • 0: OK • 1: Degraded • 2: Fault • 3: Unknown • 4: N/A string If Health is not OK, the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 378
Type Description string Shows whether use of Network Time Protocol (NTP) is enabled. • activated: NTP is enabled. • deactivated: NTP is disabled. This is the default. string • The current NTP server IP address if NTP is enabled. • The last-set NTP server IP address if NTP was enabled and has - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 379
pool-hist-statistics This basetype is used by show pool-statistics when the historical parameter is specified. Table 56 pool-hist-statistics properties Name number-of-ios number-of-reads number-ofwrites total-datatransferred data-read data-readnumeric data-written data-writtennumeric total-iops - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 380
store data. uint32 The number of 4-MB pages that host systems have unmapped per minute, through use of the SCSI UNMAP command, to free storage space as a result of deleting files or formatting volumes on the host. Embedded; see resettable-statistics. Embedded; see tier-statistics. 380 XML API - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 381
pool-summary This basetype is used by show pool-statistics when the historical parameter is specified. Table 58 pool-summary properties Name serial-number pool pool-histstatistics Type Description string The serial number of the pool. string The name of the pool. Embedded; see pool-hist- - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 382
pools This basetype is used by show configuration and show pools. Table 59 pools properties Name name serial-number storage-type storage-typenumeric total-size total-sizenumeric total-avail total-availnumeric snap-size snap-sizenumeric allocated-pages available-pages overcommit Type Description - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 383
Table 59 pools properties (continued) Name utility-running utilityrunning-numeric preferred-owner preferredowner-numeric owner owner-numeric rebalance rebalancenumeric migration migrationnumeric zero-scan zero-scannumeric Type Description string Job running on the disk, if any. • (blank): None. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 384
may or may not be aligned with physical block boundaries. • Mixed: The disk group contains a mix of 512n and 512e disks. This is supported, but for consistent and predictable performance, do not mix disks of different rotational speed or sector size types (512n, 512e). Numeric equivalents for pool - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 385
Table 59 pools properties (continued) Name health-numeric health-reason healthrecommendation disk-groups tiers unhealthycomponent Type Description uint32 Numeric equivalents for health values. • 0: OK • 1: Degraded • 2: Fault • 3: Unknown • 4: N/A string If Health is not OK, the reason for the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 386
port This basetype is used by show configuration and show ports. Table 60 port properties Name durable-id controller controllernumeric port port-type port-typenumeric media target-id status status-numeric actual-speed - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 387
values. • 0: 1Gb • 2: 4Gb • 3: Auto • 7: 8Gb • 11: 12Gb uint8 Applicable to an S2200 SAS controller module only. • Disabled: The port is configured to use a standard cable. • Enabled: The port is configured to use a fan-out cable. string • OK • Degraded • Fault • N/A • Unknown string Numeric - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 388
Unformatted mfg-date value. string string string City, state/province, and country where the FRU was manufactured. JEDEC ID of the FRU manufacturer. Configuration serial number. uint32 uint32 uint32 uint32 uint32 uint32 Voltage of the 12-volt power supply, in 100th of a volt. Voltage of the - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 389
Table 61 power-supplies properties (continued) Name health health-numeric health-reason healthrecommendation status status-numeric unhealthycomponent fan-details Type Description string • OK • Degraded • Fault • N/A • Unknown uint32 Numeric equivalents for health values. • 0: OK • 1: Degraded - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 390
product-info This basetype is used by show inquiry. Table 62 product-info properties Name vendor-name product-id scsi-vendor-id Type Description string Vendor name. string Product model identifier. string Vendor name returned by the SCSI INQUIRY command. 390 XML API basetype properties - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 391
provisioning This basetype is used by show provisioning. Table 63 provisioning properties Name volume volume-serial wwn controller controllernumeric disk-display disk-displayfull virtual-disk virtual-diskserial health health-numeric mapped lun-view Type Description string • Volume name. • - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 392
readcache-hist-statistics This basetype is used by show pool-statistics when the historical parameter is specified. Table 64 readcache-hist-statistics properties Name number-of-ios number-of-reads number-ofwrites total-datatransferred data-read data-readnumeric data-written data-writtennumeric - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 393
called the cache redundancy mode. • Active-Active ULP: Both controllers are active using ULP (Unified LUN Presentation). Data for volumes configured to use write-back cache is automatically mirrored between the two controllers to provide fault tolerance. • Single Controller: The enclosure contains - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 394
65 redundancy properties (continued) Name other-MC-status other-MCstatus-numeric Type Description string The operational status of the Management Controller in the partner controller. This is not factored into system health. • Not Communicating • Not Operational • Operational • Unknown uint32 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 395
refresh-counters This basetype is used by show refresh-counters. Table 66 refresh-counters properties Name basetype-name Type (Not shown) Description Shows when the data represented by the base type was last updated. • 0: The data has never been updated and is not cached. • nonzero-number: A - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 396
by a user or by a controller restart. uint32 The amount of time, in milliseconds, since this set of statistics was last sampled by the Storage Controller. uint64 The number of read operations since these statistics were last reset or since the controller was restarted. uint64 The number of write - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 397
sas-host-phy-statistics This basetype is used by show host-phy-statistics. Table 68 sas-host-phy-statistics properties Name port phy disparityerrors lost-dwords invalid-dwords reset-errorcounter Type Description string The controller ID and port number. uint32 The PHY's logical location - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 398
sas-port This basetype is used by show ports for a SAS host port. Table 69 sas-port properties Name configuredtopology width sas-lanesexpected sas-activelanes sas-disabledlanes Type Description string • Direct uint8 uint8 Number of PHY lanes in the SAS port. Expected number of PHY lanes in - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 399
sas-status-controller-a This basetype is used by show expander-status for controller A and controller B. Table 70 sas-status-controller-a properties Name enclosure-id expander-type expander-typenumeric drawer-id drawer-idnumeric controller controllernumeric wide-port-index phy-index wide-port- - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 400
Storage Controller PHY. • SC-0: Storage Controller primary PHY. • SC-1: Storage Controller alternate PHY. • SCA-A: Storage Controller A alternate PHY. • SCA-P: Storage Controller A primary PHY. • SCB-A: Storage Controller B alternate PHY. • SCB-P: Storage there is a firmware problem related to PHY - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 401
PHY disabled by a SES control page as a result of action by a Storage Controller or user. • Not ready: PHY is enabled but not ready. Appears problem exists such as a broken connector. • Drive removed: PHY disabled because drive slot is empty. • Unused - disabled by default: PHY is disabled by default - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 402
schedules This basetype is used by show schedules. Table 71 schedules properties Name name schedulespecification status next-time next-timenumeric task-to-run error-message task Type Description string Schedule name. string Schedule settings for running the associated task. string string - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 403
usmis usmis-numeric ftp ftp-numeric snmp Type Description string • Disabled: The standard SMC web server is disabled. This is the default. • Enabled: The standard SMC web server is enabled. uint32 Numeric equivalents for wbi-http values. • 0: Disabled • 1: Enabled string • Disabled: The secure - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 404
-ses inband-sesnumeric activityprogress activityprogressnumeric management-mode managementmode-numeric Type Description uint32 is disabled. • Enabled: The in-band SES interface is enabled. This is the default. uint32 Numeric equivalents for inband-ses values. • 0: Disabled • 1: Enabled string - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 405
has not been turned on or set into operation because it is initializing. This typically occurs during controller startup. • Unrecoverable: The enclosure management processor (EMP) cannot communicate with the sensor. • Unknown: The sensor is present but status is not available. • Not Installed: The - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 406
Table 73 sensors properties (continued) Name sensor-type sensor-typenumeric Type Description string • Temperature • Voltage • Current • Charge Capacity • Unknown Type uint32 Numeric equivalents for sensor-type values. • 0: Temperature • 1: Current • 2: Voltage • 3: Charge capacity • 4: Unknown - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 407
Type Description other-mc other-mc-status other-mcstatus-numeric string string uint32 Other MC Status The operational status of the Management Controller in the partner controller. This is not factored into system health. • Not Communicating • Not Operational • Operational • Unknown Numeric - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 408
shutdown-status This basetype is used by show shutdown-status. Table 75 shutdown-status properties Name controller status status-numeric Type Description string • A: Controller A. • B: Controller B. string • up: The controller is operational. • down: The controller is shut down. • not - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 409
snapshots This basetype is used by show snapshots. Table 76 snapshots properties Name durable-id virtual-diskname storage-poolname serial-number name creation-datetime creation-datetime-numeric status status-numeric status-reason status-reasonnumeric master-volumename volume-parent base-volume - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 410
for virtual snapshots. snap-data snap-datanumeric uniquedata uniquedatanumeric shareddata shareddatanumeric priority-value user_priorityvalue snapshot-type snapshot-typenumeric storage-type string The total amount of write data associated with the snapshot. uint32 Unformatted snap-data value in - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 411
snmp-writecommunity Type Description string Shows whether the Simple Network Management Protocol (SNMP) interface is enabled or disabled. • Disabled the monitor role and is shown in clear text for users having the manage role. The community string for write access. The value is obscured for - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 412
status This basetype is used by all commands except exit, help, and meta. (exit does not provide a response; help always prints text; meta does not use the status object.) Table 78 status properties Name response-type response-typenumeric response return-code component-id time-stamp time- - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 413
syslog-parameters This basetype is used by show syslog-parameters. Table 79 syslog-parameters properties Name syslog-host-ip syslognotificationlevel syslognotificationlevel-numeric syslog-hostport Type Description string The IP address of the remote syslog server to use for the notifications. - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 414
the storage system. The default is Uninitialized or how it is configured. The default is Uninitialized Info. health state. The operational status of the Management Controller in the partner controller. This is is running on the system, or is idle. Supported display languages: Arabic (ar), Portuguese, (br), - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 415
fde-securitystatus-numeric platform-type platform-typenumeric platform-brand platform-brandnumeric redundancy-mode unhealthycomponent Type Description string Storage system node World Wide Name (WWNN). string • Unsecured: The system has not been secured with a passphrase. • Secured - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 416
The interconnect information is managed in the controller firmware. ULP appears to the host as an active-active storage system where the host , stored on each disk. uint32 The number of host groups that the system supports. uint32 The maximum number of hosts that a host group can contain. uint32 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 417
uint32 The maximum number of volume groups that each controller supports. uint32 The maximum number of volumes that a volume • 1: CAPI_ONE_IP_ADDRESS_MODE For use by service personnel. For internal use only. Number of global-spare disks defined in the storage system. uint32 string Interval at - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 418
Table 81 system-parameters-table properties (continued) Name min-backingstore-size max-fc-speed max-fc-speednumeric max-iscsi-speed max-iscsispeed-numeric Type Description uint32 Not applicable. string Maximum FC host-port speed. uint32 Numeric equivalent for the max-fc-speed value. string - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 419
tasks This basetype is used by show tasks. Table 82 tasks properties Name name type status state error-message associatedvdisk-serial Type Description string Task name. string Type of operation this task performs. • EnableDSD • DisableDSD string Task status. • Uninitialized: Task is not - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 420
tier-hist-statistics This basetype is used by show pool-statistics when the historical parameter is specified. Table 83 tier-hist-statistics properties Name number-of-ios number-of-reads number-ofwrites total-datatransferred total-datatransferrednumeric data-read data-readnumeric data-written - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 421
Table 83 tier-hist-statistics properties (continued) Name number-ofinitialallocations number-ofunmaps number-of-rfccopies number-of-zeropages-reclaimed sample-time Type Description uint64 The number of 4-MB pages that are allocated as a result of host writes. This number does not include pages - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 422
zeroes for data). uint32 The number of 4-MB pages that host systems have unmapped per minute, through use of the SCSI UNMAP command, to free storage space as a result of deleting files or formatting volumes on the host. Embedded; see resettable-statistics. 422 XML API basetype properties - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 423
The serial number of the pool. string The name of the pool. string • Archive: The lowest storage tier, which uses midline spinning SAS disks ( - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 424
The serial number of the tier. string The name of the pool. string • Archive: The lowest storage tier, which uses midline spinning SAS disks ( - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 425
only if NTP is enabled. Shows whether Network Time Protocol (NTP) is in use. • activated: NTP is enabled. • deactivated: NTP is disabled. This is the default. NTP server IP address, or 0.0.0.0 if not set. time-settings-table 425 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 426
health. Table 88 unhealthy-component properties Name component-type Type Description string Component type. • super-cap: Supercapacitor pack • MC: Management Controller • port: Host port • controller: Controller module • expansion module: Expansion module • PSU: Power supply unit • disk: Disk - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 427
Table 88 unhealthy-component properties (continued) Name component-typenumeric component-id basetype primary-key health health-numeric health-reason healthrecommendation Type Description uint32 Numeric equivalents for component-type values. • 0: super-cap • 1: MC • 2: port • 3: controller • 4: - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 428
unwritable-cache This basetype is used by show unwritable-cache. Table 89 unwritable-cache properties Name unwritable-apercentage unwritable-bpercentage Type uint8 Description The percentage of cache space occupied by unwritable data in controller A. uint8 The percentage of cache space - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 429
interface. • (blank): User cannot access this interface. This is the default. string • x: User can use the Storage Management Initiative Specification (SMI-S) interface. • (blank): User cannot access this interface. This is the default. string • U: The user can access the SNMPv3 interface and view - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 430
The number of decimal places (1-10) for display of storage-space sizes. The default is 1. string The unit for display of storage-space sizes. • auto: Lets the system determine the the privacy-password property and the authentication-type property. • none: No encryption. This is the default. • DES - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 431
Numeric equivalents for privacy-type values. • 0: none • 1: DES • 2: AES string User password. For a standard user the password is represented by eight asterisks. For an SNMPv3 user this is the authentication password. string Encryption password for an SNMPv3 user whose privacy type is set to DES - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 432
Controller memory-controller FPGA firmware version. string Storage Controller loader firmware version. string Configuration API (CAPI) version. string Management Controller firmware version. string Management Controller loader firmware version. string Expander Controller firmware version - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 433
volume-groups This basetype is used by show volume-groups. Table 92 volume-group properties Name durable-id group-name serial-number type member-count volumes Type Description string Volume group ID. string The name of the volume group in the format volume-group.*, where * represents all - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 434
volume-group-view This basetype is used by show maps if volume groups exist. Table 93 volume-group-view properties Name durable-id serial-number group-name volume-viewmappings Type Description string Volume group ID. string The serial number of the volume group. string The name of the volume - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 435
, its WWPN. • For a SAS initiator, its WWPN. • For an iSCSI initiator, its node name (typically the IQN). • all other initiators: The volume's default mapping. string • For a host, its name in the format host-name.*, where the * represents all initiators in the host. • For a host group, its - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 436
volume-names This basetype is used by show volume-names. Table 95 volume-names properties Name volume-name serial-number Type Description string Volume name. string Volume serial number. 436 XML API basetype properties - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 437
volume-reservations This basetype is used by show volume-reservations. Table 96 volume-reservations properties Name volume-name serial-number reservationactive reservationactive-numeric pgr-generation host-id port reserve-key reserve-scope reserve-scopenumeric reserve-type reserve-typenumeric - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 438
The volume is in a virtual pool. storage-typenumeric uint32 Numeric equivalents for storage-type values. • 1: Virtual preferred-owner improves the performance of write operations and throughput. This is the default. • write-through: Write-through caching significantly impacts performance by - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 439
for applications that read and write small files in random order, such as transaction-based and database update applications. This is the default. • no-mirror: When this mode is enabled, each controller stops mirroring its cache metadata to the partner controller. This improves write I/O response - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 440
number. string string string uint32 • For HP-UX, a text value (set in-band by a host application) that identifies the volume. • Blank by default. World Wide Name of the volume. For a volume-copy operation, the percent complete (0%-99%). Unformatted progress value. string Name of the pool that - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 441
Table 97 volumes properties (continued) Name raidtype raidtypenumeric pi-format pi-formatnumeric health health-numeric health-reason healthrecommendation volume-group group-key Type Description string Disk group RAID level. • NRAID • RAID0 • RAID1 • RAID5 • RAID6 • RAID10 string Numeric - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 442
being deallocated from the volume each minute. uint32 The number of pages that are shared between this volume and any other volumes. This amount of storage will not be deallocated if the volume is deleted. uint64 For the controller that owns the volume, the number of times the block written to - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 443
Table 98 volume-statistics properties (continued) Name read-cachemisses small-destages full-stripewrite-destages read-aheadoperations write-cachespace write-cachepercent reset-time reset-timenumeric start-sampletime start-sampletime-numeric stop-sampletime stop-sampletime-numeric Type Description - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 444
volume-view This basetype is used by show maps and show volume-maps (Deprecated). Table 99 volume-view properties Name durable-id volume-serial volume-name volume-viewmappings Type Description string Volume ID in the form V#, where # starts at 1 and increments for each new volume to uniquely - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 445
Blank if not mapped or mapped as no-access. string Type of host access to the volume. • read-write: Read and write. This is the default. • read-only: Read only. • no-access: No access (masked). • not-mapped: Not mapped. uint32 Numeric equivalents of access values. • 0: not-mapped • 1: no-access - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 446
configured users are deleted and replaced with default user definitions and default settings: • User: manage; password: !manage • User: monitor; password: !monitor • User: ftp; password community • SNMP write community If addressing mode is Manual, IP values are preserved. If addressing mode is - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 447
Utility priority • SMART • Dynamic spare configuration • Enclosure polling rate • Host drive spin down delay • Disk background scrub • Managed logs • Single controller mode • Auto stall recovery Factory default: no tasks or schedules. 2. Factory default: MC logs are cleared. 3. Factory default: NTP - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 448
5. Factory default: certificates are initialized. 6. Factory default: host names and profiles are cleared. 448 Settings changed by restore defaults - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 449
Configuration Application Programming Interface. A proprietary protocol used for communication between the Storage Controller and the Management . It provides a common definition of management information for systems, networks, applications and services, and allows for vendor extensions. CIM - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 450
Configuration Storage Controller processor; a Management Controller processor; a SAS expander and Expander Controller processor; management interfaces; cache protected by a supercapacitor pack and nonvolatile memory (CompactFlash); host, expansion, network, and service or a support technician default - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 451
disk group A set of disk drives that is configured to use a specific RAID type and provides storage capacity for a pool. See also virtual disk group. Distributed Management Task Force See DMTF. DMTF Distributed Management Task Force. An industry organization that develops and maintains - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 452
LFF LIP lock key logical block address Logical Unit Number loop Loop Initialization Primitive LUN MAC address Field-programmable gate array. An integrated circuit designed to be configured after manufacturing. Field-replaceable unit. A part that can be removed and replaced by the user or support - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 453
mapped to storage devices. Paged storage is also called virtual storage. A volume that has snapshots (can be either a base volume or a base snapshot volume). The parent of a snapshot is its immediate ancestor in the snapshot tree. See PFU. A user-created password that allows users to manage lock - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 454
active configuration, syslog support See Storage Controller. A processor (located in a controller module) that is responsible for RAID controller functions. The SC is also referred to as the RAID controller. See also EC and MC. SCSI Enclosure Services See SES. secret For use with CHAP, a password - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 455
small form factor See SFF. SMART Self-Monitoring Analysis and Reporting Technology. A monitoring system for disk drives that monitors reliability indicators for the purpose of anticipating disk failures and reporting those potential failures. SMC Storage Management Console. The web application - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 456
volumes that use paged-storage technology to virtualize data storage. See paged storage. virtual disk group A set of disk drives that is configured to use a specific WBI Web-browser interface, called Storage Management Console. The primary interface for managing the system. A user can enable - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 457
World Wide Port Name See WWPN. WWN World Wide Name. A globally unique 64-bit number that identifies a device used in storage technology. WWNN World Wide Node Name. A globally unique 64-bit number that identifies a device. WWPN World Wide Port Name. A globally unique 64-bit number that - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 458
76 output formats 13 scripting commands 14 scripting guidelines 18 set base for storage-space sizes 115 set locale 116 set output format 115 set paging mode scheduled task 24 service utilities 24 snapshot 24 statistics 24 system configuration and utilities 24 volume, host, and mapping 24 Index 458 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 459
CompactFlash failure trigger enable/disable 108 show setting 166 configuration limits 258, 416 show system 175 controller notify partner debug interface enable/disable 152 debug log set parameters 120 show parameters 182 default LUN 79 DHCP enable/disable 145 disk locate 144 syntax 20 disk channels - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 460
63 remove members 85 show 212 show maximum number of 258 host link See host ports host ports reset 95 reset performance statistics 96 set default router address for iSCSI 137 set FC connection mode 137 set FC link speed 138 set gateway address for iSCSI 137 set IP address for - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 461
user 52, 160 show CLI 173 show user 266 lock key clear FDE 40 set FDE 132 log management enable/disable 109 send events to syslog on a remote system 157 show setting 167 LUNs set response to version for addressing 146 Network Time Protocol See NTP NTP configure 118, 147 show settings 229 Index 461 - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 462
enable/disable 109 show setting 165 password rules for user 21 set user /disable 109 show setting 166 precision for storage-space sizes set CLI 116 set user system 133 rescan disk channels 89 restore system defaults 103, 446 revert volume data See roll manual volume 121 SCSI MODE SELECT command set - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 463
267 SNMPv3 authentication type 51, 159 privacy/encryption password 52, 160 privacy/encryption type 52, 160 263 show volume performance 277 Storage Controllers restart 102 supercapacitor defaults 103, 446 set contact 158 set information/description 158 set location 158 set name 158 show configuration - Lenovo Storage E1024 | (English) Command Line Interface Reference Guide - Lenovo - Page 464
52, 160 set base for storage-space sizes 51, 160 set locale 52, 160 set management-interface access 52, 160 set name 161 set password 52, 148, 160 set precision 163 set name 163 show amount of unwritable cache data 265 start manual scrub 121 syntax 21 unmap 288 volume group add volumes 33 create 57
Lenovo Storage
CLI Reference Guide
For firmware release GL210 or later
Part Number: 00WE612
Abstract
This guide provides information about managing a Lenovo Storage S3200/S2200 storage system by using its command-line