Lenovo ThinkServer RD120 Hardware Maintenance Manual for RD120
Lenovo ThinkServer RD120 Manual
View all Lenovo ThinkServer RD120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Lenovo ThinkServer RD120 manual content summary:
- Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 1
ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447 Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 2
- Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 3
ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447 Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 4
, and the Warranty and Support Information document on the ThinkServer Documentation DVD. Second Edition (June 2009) © Copyright Lenovo 2008. Portions © Copyright International Business Machines Corporation 2007. LENOVO products, data, computer software, and services have been developed exclusively - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 5
servicing electrical equipment ix Safety statements xi Chapter 1. Introduction 1 Related documentation 1 Notices and statements in this document 2 Features and specifications 21 Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 25 Replaceable server - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 6
146 Troubleshooting tables 147 CD or DVD drive problems 147 General problems 148 Hard disk drive problems 148 Intermittent problems 149 USB keyboard, mouse, or pointing-device problems 150 iv ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 7
the BIOS code 181 System event/error log messages 184 Solving power problems 192 Solving Ethernet controller problems 194 Solving undetermined problems 194 Problem determination tips 195 Calling Lenovo for service 196 Appendix A. Getting help and technical assistance 197 Before you call - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 8
vi ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 9
instalar este produto, leia as Informações sobre Segurança. Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten. © Lenovo 2008. Portions © IBM Corp. 2007. vii - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 10
is disconnected. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc not frayed or worn. viii ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 11
supplies power to the equipment and lock the wall box in the off position. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 12
generators, do not service these components outside of their normal operating locations. v If an electrical accident occurs, use caution, turn off the power, and send another person to get medical aid. x ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 13
contains dc power supplies, see the documentation that comes with the dc power supplies. In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply and to install and remove a dc power supply - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 14
and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures. v Connect and cables from connectors. 4. Remove all cables from devices. xii ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 15
Statement 2: CAUTION: When replacing the lithium battery, use only the battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 16
directly with optical instruments, and avoid direct exposure to the beam. Class 1 Laser Product Laser Klasse 1 Laser Klass 1 Luokan 1 Laserlaite Appareil A` Laser de Classe 1 xiv ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 17
Statement 4: ≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) CAUTION: Use safe practices when lifting. Statement 5: ≥ 55 kg (121.2 lb) CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 18
serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. Statement 26: CAUTION: Do not place any object on top of rack-mounted devices. xvi ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 19
Maintenance Manual contains information to help you solve problems that might occur in the Lenovo ThinkServer™ RD120 Machine Types 6444, 6445, 6446, and 6447 server. It describes the diagnostic tools that come with the server, error codes and suggested actions, and instructions for replacing - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 20
Go to: http://www.lenovo.com/support. 2. Enter your product number (machine type and model number) or select Servers from the Select your product list. 3. Select Servers from the Brand list. 4. From Family list, select ThinkServer RD120, and click Continue. 5. Click Downloads and drivers to download - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 21
just before the description of a potentially lethal or extremely hazardous procedure step or situation. Features and specifications The following information is a summary of the features and specifications of the server. Depending on the server model, some features might not be available, or some - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 22
available), in pairs v Chipkill™ supported Drives: CD/DVD: IDE 24x CD-RW/ 8x DVD combination Expansion bays: v Hot-swap hard disk drive bays: SAS only. Number and - Minimum: 0.29 kVA - Maximum: 1.00 kVA 4 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 23
LED (amber) 2 USB 5 connector 7 Rack release latch 3 USB 6 connector 8 CD/DVD eject button 4 Video connector 9 CD/DVD drive activity LED 5 Hard disk drive activity LED (green) 10 Rack release latch The following illustration shows the controls, light-emitting diodes (LEDs), and connectors on - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 24
it indicates that the drive is in use. Hard disk drive status LED: Each hot-swap hard disk drive has a status LED. When this LED is lit, it indicates that the drive has failed. When this LED is flashing 6 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 25
DVD from the CD-RW/DVD drive. CD/DVD drive activity LED: When this LED is lit, it indicates that the CD-RW/DVD drive is in use. Rack release Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 26
, and jumpers The illustrations in this section show the LEDs, connectors, and jumpers on the internal boards. The illustrations might differ slightly from your hardware. 8 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 27
System-board optional-device connectors The following illustration shows the connectors on the system board for user-installable optional devices. 1 PCI Express slot connectors (2) 2 Remote Supervisor Adapter II SlimLine connector 3 PCI riser card connector 4 ServeRAID SAS connector 5 DIMM - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 28
board connectors The following illustration shows the internal connectors on the power-backplane board. 1 Fan 10 connector 2 Hard disk drive power connector 3 Fan 7 connector 4 System-board connector 10 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 29
System-board internal cable connectors The following illustration shows the internal connectors on the system board. 1 Hard disk drive backplane signal (J92) 2 Power backplane (J72) 3 Tape drive power (J100) 4 Front USB (J80) 5 Front video (J51) 6 Internal USB (J82) 7 CD/DVD signal (J37) 8 CD/DVD - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 30
external connectors The following illustration shows the external input/output connectors on the system board. 1 Ethernet/USB (2) 2 USB (2) 3 Video 4 Serial 5 Systems-management Ethernet 6 SAS 12 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 31
System-board switches and jumpers The following illustration shows the switches and jumpers on the system board. Any switches or jumpers on the system board that are not shown in the illustration are reserved. See "Recovering the BIOS code" on page 181 for information about the boot block recovery - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 32
than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 2. Any system-board switch or jumper blocks that are not shown in the illustrations in this document are reserved. 14 ThinkServer RD120 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 33
functioning normally. 12-volt power (A, B, C, D) LEDs If any of these LEDs is lit, there is a failure in the associated system board power channel (see "Power problems" on page 155). Chapter 1. Introduction 15 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 34
Riser-card assembly LEDs The following illustration shows the light-emitting diodes (LEDs) on the riser-card assembly. 1 PCI slot 1 error LED 2 PCI slot 2 error LED 16 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 35
Chapter 2. Configuration information and instructions This chapter provides information about updating vital product data (VPD) code, device drivers, and service processor firmware, use the ThinkServer EasyUpdate program or go to: http://www.lenovo.com/support/. When you replace a device in the - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 36
tasks: v Sets the system date and time v Detects installed hardware devices v Guides the network administrator through the process of creating a response file v Prepares the hard disk for installation 18 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 37
drivers for most adapters and devices Setup and configuration: When you start the ThinkServer supported by that version of the EasyStartup program. v User Guide , prepares the hard disk for installation whether you want to repartition the selected drive or use an existing partition. v Partition - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 38
this document. 1. Go to: http://www.lenovo.com/support. 2. Enter your product number (machine type and model number) or select Servers from the Select your product list. 3. Select Servers from the Brand list. 4. From Family list, select ThinkServer RD120, and click Continue. 5. Select the operating - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 39
RAID level-0, level-1, and level-10. You can replace it with a ServeRAID-8k SAS controller that supports additional RAID levels. v Hard disk drive capacities affect how you create arrays. The drives in an array can have different capacities, but the ServeRAID controller treats them as if they all - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 40
select express configuration or custom configuration. Express configuration automatically configures the controller by grouping the first two physical drives in the ServeRAID Manager tree into an array 22 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 41
hot-spare drives, and physical drives). When you click an object in the ServeRAID Manager tree, information about that object appears in the right pane. To display a list of available actions for an object, click the object and click Actions. Chapter 2. Configuration information and instructions 23 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 42
24 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 43
are available for the ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447, except as specified otherwise in "Replaceable server components." For an updated parts listing, consult the latest version of the Hardware Maintenance Manual on the Lenovo Support Web site. Replaceable server - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 44
-swap, with tray (models) 45J9652 Hard disk drive, SAS, 2.5-inch 73 GB, 10K, hot-swap, with tray (models) 45J9654 CRU part number (Optionalservice) 42C9487 24R2731 24R2733 40K6552 26 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual FRU part number - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 45
front USB (all models) Cable, hard disk drive signal (all models) Cable, USB signal (optional-device) (all models) CRU part number (Self-service) 26K8680 CRU part number (Optionalservice FRU part number 41Y8733 Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 27 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 46
part number (Self-service) CRU part number (Optionalservice) 25R0048 41Y8724 41Y8730 40K6556 40K6591 40K6592 41Y8731 41Y8730 41Y8740 39Y7191 43W4325 25R8079 44T1412 FRU part number 41U3013 41A5100 28 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 47
service label (all models) CRU part number (Optionalservice) 42C9487 24R2731 24R2733 40K6552 39M4375 39M3541 39M3563 39M3533 43W0626 41Y8739 41Y8735 part of 41Y8727 41Y8726 46C4014 44E8850 41Y8737 FRU part number 41Y8733 Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 48
2.5-inch hard disk drive power (all models) Cable, 3.5-inch hard disk drive power (all models) Cable, front video (all models) Cable, front USB (all models) Cable, hard disk drive signal 41A5100 30 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 49
Types 6446 Index 1 2 3 4 5 6 6 7 8 9 9 9 9 9 9 10 11 11 11 12 15 16 17 Description CRU part number (Self-service) Cover , 2.5-inch drive (all models) Hard disk drive, SAS, 2.5-inch 146 GB, 10K, hot-swap, with tray (models 12U 12F 12S ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 31 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 50
26K8068 39M6759 39M6761 39M6763 42C2378 39M6781 25R0048 41Y8724 41Y8730 40K6556 40K6591 40K6592 41Y8731 41Y8730 41Y8740 39Y7191 43W4325 25R8079 44T1412 FRU part number 41U3013 41A5100 32 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 51
CRU part number (Self-service) Cover (all models) Hard disk drive, SAS, 3.5-inch 300 GB, 15K, hot-swap, with tray (models) 45J9660 CRU part number (Optionalservice) 42C9487 24R2731 24R2733 40K6552 FRU part number 41Y8733 Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 52
part of 41Y8727 41Y8726 46C4014 44E8850 41Y8737 41Y8738 39M5377 40K6497 41Y8727 33F8354 39M6765 39M6757 26K8068 39M6759 39M6761 39M6763 42C2378 39M6781 25R0048 41Y8724 41Y8730 40K6556 34 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual FRU part number - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 53
models) DVD drive retention clip (all models) DVD drive filler (all service) CRU part number (Optionalservice) 40K6591 40K6592 41Y8731 41Y8730 41Y8740 39Y7191 43W4325 25R8079 44T1412 FRU part number 41U3013 41A5100 View 2 Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 54
-service) PCI Express riser-card assembly (all models) PCI-X riser-card assembly (optional) (all models) Full-length adapter (models) varies DIMMs air baffle (all models) 41Y8727 Memory, 36 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual FRU - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 55
models) Battery, Adaptec 8K battery (all models) CRU part number (Self-service) varies CRU part number (Optionalservice) 39M6800 40K7438 25R8088 FRU part number 44R5646 44R5647 44R5648 44R5649 42D3788 44R5645 Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 37 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 56
24R2694 FRU part number 46M7131 41Y4275 41Y4276 41Y4277 41Y4278 41Y4279 41Y4280 41Y8905 41Y8904 43W5174 43W5175 43W5915 43W5916 43W5182 43W5183 43W5184 44E5040 44E5066 44E5117 44E5144 38 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 57
8K battery (all models) CRU part number (Self-service) CRU part number (Optionalservice) varies 39M6800 40K7438 25R8088 FRU part number 44E5145 44R5644 44R5646 44R5647 44R5648 44R5649 42D3788 44R5645 Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 39 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 58
13Q 13T 13K 13R 13E 13J) 46U1017 Memory, 2 GB PC2-5300 (option) (models 12U 12F 12S 12L 12D 12Y 14M 14A 14Q 14T 14K 14R 14E 14J) 46U1018 Memory, 4 GB PC2-5300 (option) (models 43W5184 44E5040 40 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 59
Table 10. View 2 parts listing, Types 6446 (continued) Index 9 9 9 9 9 9 9 9 9 9 9 10 11 13 Description CRU part number (Self-service) Microprocessor, Intel Xeon X5460 Quad-Core 3.16 GHz/ 42D3788 44R5645 Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 41 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 60
17L 17D 17Y 17G 17B 17H 17V) Memory, 4 GB PC2-5300 (option) ( service) varies part of 41Y8727 46U1017 46U1018 46U1019 CRU part number (Optionalservice) 39Y6788 43W5861 25R8079 25R8076 39M6783 24R2694 42 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 61
9 9 9 9 9 9 9 9 9 9 9 9 9 9 10 11 13 Description CRU part number (Self-service) Microprocessor, 1.60 GHz, quad core, 8MB (models) Microprocessor, 1.86 GHz, quad core, 8MB (models) Microprocessor, 2.0 44R5645 Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 43 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 62
parts listing on the Lenovo Support Web site) Used in these countries and regions 39M5206 China (models) 39M5102 Australia, Fiji, Kiribati, Nauru, New Zealand, Papua New Guinea (models 12M) 44 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 63
cord part number (available in the updated parts listing on the Lenovo Support Web site) Used in these countries and regions 39M5123 Afghanistan, Albania , Taiwan, United States of America, Venezuela (models) Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 45 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 64
cord part number (available in the updated parts listing on the Lenovo Support Web site) Used in these countries and regions 39M5081 110 - 12Q) 39M5233 Brazil (models) 39M5247 Taiwan (models) 46 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 65
power cord part number (available in the updated parts listing on the Lenovo Support Web site) Used in these countries and regions 39M5206 China (models) 39M5102 12G 13G) 39M5179 Europe (models 11G 12G 13G) Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 47 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 66
in the updated parts listing on the Lenovo Support Web site) Used in these countries and Thailand, Taiwan, United States of America, Venezuela (models 12U 12F 12S 12L 12D 12A 12T 14U 14F 14S 14L 48 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 67
Table 14. Power cords, Type 6446 Lenovo power cord part number (available in the updated parts listing on the Lenovo Support Web site) Used in these countries and , United States of America, Venezuela (models) Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 49 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 68
6446 (continued) Lenovo power cord part number (available in the updated parts listing on the Lenovo Support 15L 15D 15A 15T 11U 11F 11S 11L 11D 11A 11T 12U 12F 12S 12L 12D 13A 13T 14A 14T) 39M5219 Korea ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 69
power cord part number (available in the updated parts listing on the Lenovo Support Web site) Used in these countries and regions 39M5206 China (models) 39M5102 Australia 21G 22G 24G 27G 11G 13G 14G 16G) Chapter 3. Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 51 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 70
power cord part number (available in the updated parts listing on the Lenovo Support Web site) Used in these countries and regions 39M5095 220 - 240 V ) 39M5247 Taiwan (models 11V 14V 15V 17V) 52 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 71
Go to: http://www.lenovo.com/support. 2. Enter your product number (machine type and model number) or select Servers from the Select your product list. 3. Select Servers from the Brand list. 4. From Family list, select ThinkServer RD120, and click Continue. 5. Click Downloads and drivers to download - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 72
on the server. Operating the server for extended periods of time (more than 30 minutes) with the server cover removed might damage server components. 54 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 73
cabling instructions that come with optional adapters. v You have replaced a failed fan within 48 hours. v You have replaced a hot-swap drive problem, always use an electrostatic-discharge wrist strap or other grounding system when working inside the server with the power on. The server supports - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 74
before turning on the server. Operating the server for extended periods of time (over 30 minutes) with the cover removed might damage server components. 56 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 75
to return the cover, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. Installing the cover To install the cover, complete the following steps. 1. Make sure - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 76
power environment, only trained service personnel other than Lenovo service technicians are authorized to you are instructed to return the microprocessor air baffle, follow all packaging instructions, and ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 77
reconnect the power cords and turn on the peripheral devices and the server. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 78
CD-RW/DVD drive, you must Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 3. Remove the cover (see "Removing the cover" on page 56). 60 ThinkServer RD120 server Machine Types 6444, 6445, 6446 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 79
reconnect the power cords and turn on the peripheral devices and the server. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 80
the server. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc damage server components. 62 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 81
assembly with one that contains two PCI-X 64-bit 133 MHz connectors that support single-width IXA adapters. To remove the riser-card assembly, complete the : In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 82
a Remote Supervisor Adapter II SlimLine" on page 67. To remove the ServeRAID SAS controller, go to "Removing the ServeRAID SAS controller" on page 69. 64 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 83
: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power from the PCI slot. 7. If you are instructed to return the adapter, follow all packaging instructions, and use any packaging materials for shipping that - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 84
, complete the following steps. 1 Expansion slot cover 2 Raiser-card assembly 3 Expansion slot 1 4 Adapter 5 Low-profile PCI Express adapter 6 Expansion slot cover 7 Expansion slot 2 8 Adapter 66 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 85
reconnect the power cords and turn on the peripheral devices and the server. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 86
not work in this server. See http://www.lenovo.com/support/ for the supported Remote Supervisor Adapter II SlimLine. To install the Remote Supervisor Adapter II SlimLine, complete the following steps. 68 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 87
reconnect the power cords and turn on the peripheral devices and the server. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 88
service personnel other than Lenovo service instructed to return the ServeRAID SAS controller, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. 70 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 89
Installing a ServeRAID SAS controller To install the ServeRAID-8k-l SAS Controller or the ServeRAID-8k SAS Controller, complete the following steps. Note: The following illustration shows installing a ServeRAID-8k SAS controller; the ServeRAID-8k-l SAS controller does not have a battery. 1 RAID - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 90
trained service personnel other than Lenovo service hard disk drive To remove a hard disk drive from a hot-swap bay, complete the following steps. 3.5-inch drives 1 Tray handle 2 Hard disk drive 72 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 91
with the hard disk drive and follow those instructions in addition to the instructions in this section. For information about the type of hard disk drive that the server supports and other information that you must consider when installing a hard disk drive, see the User Guide on the ThinkServer - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 92
. If the amber hard disk drive status LED for a drive is lit continuously, that drive is faulty and must be replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed. 74 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 93
hard disk drives. See the RAID documentation on the IBM ServeRAID Support CD for information about RAID controllers. Removing a CD-RW/DVD drive To remove the CD-RW/DVD drive a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 94
). 5. Slide the server into the rack. 6. Reconnect the external cables; then, reconnect the power cords and turn on the peripheral devices and the server. 76 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 95
environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. Removing an optional SATA tape drive To remove a tape drive from the server, complete - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 96
drive backplane signal cable from the system board (see the illustration on page "System-board internal cable connectors" on page 11 for the location of the hard disk drive backplane signal connector). 78 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 97
, and reinstall the hard disk drive backplane cable, DIMM air baffle, and riser-card assembly (see "Installing the DIMM air baffle" on page 62 and "Installing the riser-card assembly" on page 64). 11. If you are instructed to return the drive, follow all packaging instructions, and use any packaging - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 98
gently pulling the cables farther into the server as you do so, until the tape-drive assembly stops. 6. Push the tray handle to the closed (locked) position. 7. 57). 10. Slide the server into the rack. 80 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 99
personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. Installing a SATA tape drive in a 2.5-inch model server To install a tape drive in a 2.5-inch model server, complete - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 100
in the two bottom-left hard disk drive bays. See the documentation that comes with the enablement kit for the original tape drive for instructions for mounting the tape drive on the tape-drive tray. 82 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 101
to 8 cm (2 to 3 in.). 4. Connect the cables to the back of the tape drive. 5. Push the tape-drive assembly into the bays, gently pulling the cables farther into the server as you do so, until the tape-drive assembly stops. 6. Push the tray handle to the closed (locked) position. Chapter 4. Removing - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 102
hook-and-loop fastener on top of the CD/DVD drive bay. 8. Make sure that the SCSI signal cable 1 is routed to the supported SCSI adapter that is installed in slot 1 of cables avoid any fan connectors. 84 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 103
is positioned on top of the SCSI signal cable and that both cables pass through the cable clamp. Close the cable clamp. 11. Reconnect the hard disk drive backplane signal cable to the connector (J92) on the system board (see "System-board internal cable connectors" on page 11 for the location of - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 104
attached to the inside top of the tape-drive bay as shown in the following illustration. If necessary, press the terminator onto the corresponding hook-and-loop fastener on the inside top of the bay. 86 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 105
terminator 5. Make sure that the tape-drive power cable is connected to the tape-drive power connector, J100 (see "System- Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. Removing a memory - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 106
in connectors 1 and 7 instead of 1 and 4. However, because the connectors in the pair are not on the same memory branch (see the following illustration), Advanced ECC memory protection is disabled. 88 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 107
mirroring DIMM functions Group Active DIMMs 1 1, 4 2 2, 5 3 3, 6 Mirroring DIMMs 7, 10 8, 11 9, 12 v Several online-spare memory configurations are supported. The online-spare DIMM pairs must be the same speed, type, and the same size as, or larger than, the largest active DIMM pairs - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 108
4 (dual-rank DIMMs only) 10 1 and 4 (largest DIMMs) 2 and 5 Online-sparing on branch 0 Online-sparing on branch 1 7 and 10 8 and 11 9 and 12 12 N/A N/A 90 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 109
reconnect the power cords and turn on the peripheral devices and the server. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 110
server. 4. If you are instructed to return the fan, follow all packaging instructions, and use any packaging materials that are shown in the following table are supported. The fan numbers are printed on the ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 111
contains dc power supplies, see the documentation that comes with the dc power supplies. In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply and to install and remove a dc power supply - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 112
service personnel other than Lenovo service support the power supply and pull it the rest of the way out of the bay. 9. If you are instructed to return the power supply, follow all packaging instructions ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 113
Lenovo service technicians are authorized to connect or disconnect power to the dc power supply and to install and remove a dc power supply. The server supports are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. Chapter - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 114
3 Power supply filler Attention: During normal operation, each power-supply bay must have either a power supply or power-supply blank installed for proper cooling. 96 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 115
contains dc power supplies, see the documentation that comes with the dc power supplies. In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply and to install and remove a dc power supply - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 116
batteries in U.S. and Canada, call Lenovo Service and Support. Outside the U.S. and Canada, call your Lenovo marketing representative or authorized reseller. v Locate the battery 1 on the system board. 98 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 117
9. Remove the battery: a. Use one finger to push the battery horizontally out of its housing. b. Lift the battery from the socket. 10. Dispose of the battery as required by local ordinances or regulations. See "Battery return program" on page 204 for more information. Installing the battery The - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 118
battery, complete the following steps: 1. Follow any special handling and installation instructions that come with the replacement battery. 2. Insert the new battery: a. Slide the server into the rack. 100 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 119
contains dc power supplies, see the documentation that comes with the dc power supplies. In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply and to install and remove a dc power supply - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 120
instructions, and use any packaging materials for shipping that are supplied to you. Installing the operator information panel assembly To install the replacement operator information panel assembly, complete the following steps. 102 ThinkServer RD120 server Machine Types 6444, 6445, 6446 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 121
1 Ribbon cable 2 Release tabs 3 Operator information panel 1 Operator information panel 2 Release latch 1. From the front of the server, thread the operator-information-panel ribbon cable through the panel housing in the server; then, connect the ribbon cable to the operator-panel - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 122
a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or hard disk drive backplane. 9. Lift the power backplane out of the server. 104 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 123
instructions, and use any packaging materials for shipping that are supplied to you. Installing the power backplane To install the power backplane, complete the following steps. 1 Power backplane connector Attention: In a dc power environment, only trained service personnel other than Lenovo - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 124
trained service personnel other than Lenovo service instructed to return the media backplane, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. 106 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 125
personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. Installing and removing the hard disk drive backplane The procedure to use for installing or removing the Serial Attached - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 126
. The hard disk drive backplane pops out. 9. Lift the backplane out of the server. 10. If you are instructed to return the backplane, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. 108 ThinkServer RD120 server Machine Types 6444, 6445, 6446 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 127
the rack. 8. Insert the hard disk drives into the bays. 9. Reconnect the external cables; then, reconnect the power cords and turn on the peripheral devices and the server. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 128
; then, push the drive-cage assembly out through the front of the server. 9. If you are instructed to return the backplane, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. 110 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 129
the rack. 7. Insert the hard disk drives into the bays. 8. Reconnect the external cables; then, reconnect the power cords and turn on the peripheral devices and the server. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 130
cables. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the the heat sink out of the server. 112 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 131
If you are instructed to return the microprocessor, follow all packaging instructions, and use any supports and other information that you must consider when installing a microprocessor, see the User Guide on the ThinkServer lenovo.com/support/ Chapter 4. Removing and replacing server components 113 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 132
3 Microprocessor 4 Microprocessor socket dust cover 1. If you are installing microprocessor 2, and are replacing the VRM, install the new VRM in the VRM connector (J72). 114 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 133
1 Alignment key a. Touch the static-protective package containing the VRM to any unpainted metal surface on the outside of the server. Then, remove the VRM from the package. b. Turn the VRM so that the keys align correctly with the VRM connector. c. Firmly press the VRM straight down into the - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 134
the plastic protective cover from the bottom of the heat sink. c. Align the heat sink above the microprocessor with the thermal grease side down. 116 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 135
reconnect the power cords and turn on the peripheral devices and the server. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 136
power environment, only trained service personnel other than Lenovo service technicians are authorized to you are instructed to return the heat-sink retention module, follow all packaging instructions, and ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 137
reconnect the power cords and turn on the peripheral devices and the server. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 138
cables. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc II SlimLine" on page 67) 120 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 139
protective surface for reinstallation (see "Removing a memory module (DIMM)" on page 87). 7. power environment, only trained service personnel other than Lenovo service technicians are authorized to are instructed to return the system board and shuttle assembly, follow all packaging instructions, and - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 140
95). Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc Slide the server into the rack. 122 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 141
Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to only. If the center bracket between the two columns of 3.5-inch hard disk drives becomes damaged, you can replace it. To remove the center - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 142
, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 124 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 143
problem. See "POST" for more information. v Troubleshooting tables These tables list problem symptoms and actions to correct the problems. See "Troubleshooting memory problems, a single beep sounds, and the server startup is completed. If POST detects a problem has detected a problem. To determine the - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 144
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 145
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 146
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 147
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 148
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 149
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 150
Repeat steps 2b through 2d until you have checked all memory banks. 3. Replace the following components, one at a time, in the order shown: a. DIMMs b. (Trained service technician only) System board 132 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 151
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 152
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 153
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 154
system status messages from the service processor. The following illustration shows are described in the User Guide). When you are troubleshooting an error, be sure to Guide for more information). 136 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 155
5. From the list, select BMC Log. Clearing the error logs For complete information about using the Configuration/Setup Utility program, see the User Guide. To clear the error logs, complete the following steps: 1. Turn on the server. 2. When the prompt Press F1 for Configuration/Setup appears, press - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 156
about how to clear CMOS memory. 3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Battery b. (Trained service technician only) System board 138 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 157
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 158
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 159
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 160
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 161
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 162
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 163
this might enable the hard disk drive diagnostic tests. v If the server is halted and a POST error code is displayed, see "Error logs" on page 136. If the server is halted and no error message is displayed, see "Troubleshooting tables" on page 147 and "Solving undetermined problems" on page 194 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 164
you still suspect a problem, see "Solving undetermined problems" on page 194. v Yes: Find the beep code in "POST beep codes" on page 125; if necessary, see "Solving undetermined problems" on page 194. 146 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 165
the new software or new device. CD or DVD drive problems v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 166
a similar trained service technician. problem has occurred. Hard disk drive problems v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 167
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 168
shown, restarting the server each time: a. Mouse or pointing device b. (Only if the problem occurred with a front USB connector) Internal USB cable c. (Trained service technician only) System board 150 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 169
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 170
you suspect a problem with your monitor, see the documentation that comes with the monitor for instructions for testing and adjusting the monitor. If you cannot diagnose the problem, call for service. 152 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 171
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 172
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 173
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 174
documentation that comes with each dc power supply. b. (Trained service technician only) System board 7. See "Solving power problems" on page 192. 8. See "Solving undetermined problems" on page 194. 156 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 175
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 176
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 177
is present) d. (Trained service technician only) System board EasyStartup problems v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 178
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 179
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 180
Hard disk drive activity LED Diagnostics panel. REMIND Light Path Diagnostics OVER SPEC PS1 PS2 CPU VRM CNFG MEM NMI S ERR into the server. Look at the system service label on the top of the server, which ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 181
error LEDs indicate an overcurrent condition. Table 21 on page 193 identifies the components associated with each power channel, and the order in which to troubleshoot the components. The following illustration shows the LEDs on the riser card. Chapter 5. Diagnostics 163 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 182
Lenovo service technicians are authorized to connect or disconnect power to the dc power supply and to remove and install a dc power supply. See the documentation that comes with each dc power supply. 164 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 183
problem remains, replace the failed power supply. Attention: In a dc power environment, only trained service personnel other than Lenovo service the microprocessor section of the User Guide for compatibility requirements). 2. (Trained service technician only) Replace an incompatible microprocessor - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 184
adapter is removed. If the problem remains, replace the following components, in the order shown, restarting the server each time: v PCI riser card v (Trained service technician only) System board 166 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 185
the power-on LED on the operator information panel and suggested actions to correct the detected problems. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply and to install - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 186
the instructions on the screen. When you are diagnosing hard disk drives, select SCSI Attached Disk Test for the most thorough test. Select Fixed Disk Test for any of the following situations: v You want to run a faster test. v The server contains RAID arrays. 168 ThinkServer RD120 server Machine - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 187
SATA or IDE hard disk drives. For help server and try running the diagnostic programs again. If the problem remains, replace the component that was being tested when the as system configuration, memory contents, interrupt request (IRQ) use, direct memory access (DMA) use, device drivers, and so on - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 188
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 189
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 190
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 191
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 192
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 193
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 194
drive backplane 4. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive backplane b. (Trained service technician only) System board 176 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 195
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 196
a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or Hard disk drive backplane b. (Trained service technician only) System board 178 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 197
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 198
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 199
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 200
service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply. 3. Remove the server cover. See "Removing the cover" on page 56 for more information. 182 ThinkServer RD120 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 201
recovery mode. 6. Insert the BIOS recovery diskette into the diskette drive. 7. Reinstall the server cover; then, reconnect all power cords. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 202
cover. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc correct the detected problems. 184 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 203
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 204
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 205
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 206
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 207
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 208
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 209
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 210
problem is solved. v See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 211
the overcurrent condition is identified. Important: Only a trained service technician should remove or replace a FRU, such as a microprocessor or the system board. See Chapter 3, "Parts listing, ThinkServer RD120 Machine Types 6444, 6445, 6446, and 6447," on page 25 to determine whether a component - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 212
and that the correct device drivers are installed. v Check for operating-system-specific causes of the problem. v Make sure that the device drivers on the client and server server is cabled correctly. 194 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 213
device (on the server). v Modem, printer, mouse, and non-Lenovo devices. v Each adapter. v Hard disk drives. v Memory modules. The minimum configuration requirement is 1 GB (two 512 MB DIMM, in DIMM slots 1 and 4). v Service processor (Remote Supervisor Adapter II SlimLine). The following minimum - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 214
Lenovo for service. When you call for service, have as much of the following information available as possible: v Machine type and model v Microprocessor and hard disk drive solve some problems by comparing ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 215
to the Lenovo Support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new device drivers or to submit a request for information. You can solve many problems without outside assistance by following the troubleshooting procedures that Lenovo provides in - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 216
Warranty Service, which automatically entitles you to obtain warranty service throughout the warranty period. Service will be performed by service providers authorized to perform warranty service. 198 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 217
. To determine whether your computer is eligible for International Warranty Service and to view a list of the countries where service is available, go to http://www.lenovo.com/support, click Warranty, and follow the instructions on the screen. For technical assistance with the installation of, or - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 218
200 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 219
operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 220
to hard disk drive capacity or communications volume, MB stands for 1 000 000 bytes, and GB stands for 1 000 000 000 bytes. Total user-accessible capacity can vary depending on operating environments. 202 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 221
of all hard disk drive bays with the largest currently supported drives that are available from Lenovo. Maximum memory might require replacement of the standard memory with an optional memory module. Lenovo makes no representation or warranties regarding non-Lenovo products and services, including - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 222
local Lenovo representative. Battery return program This product may contain a lithium or lithium ion battery. Consult your user manual or service manual for specific battery life per this Directive. 204 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 223
and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this and connectors must be used in order to meet FCC emission limits. Lenovo is not responsible for any radio or television interference caused by using - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 224
Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der Lenovo verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne Empfehlung der Lenovo gesteckt/eingebaut werden. 206 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 225
EMVG das EG-Konformitätszeichen - CE - zu führen. Verantwortlich für die Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo (Deutschland) GmbH, Gropiusplatz 10, D-70563 Stuttgart. Informationen in Hinsicht EMVG Paragraf 4 Abs. (1) 4: Das Gerät erfüllt die Schutzanforderungen nach - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 226
Taiwanese Class A warning statement Chinese Class A warning statement Korean Class A warning statement 208 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 227
system-board jumpers 13 VRM 9 cooling 4 cover installing 57 removing 56 CRUs, replacing adapter 64 battery 97 CD-RW/DVD drive 75 cover 57 DIMMs 87 hard disk drive 72 memory 87 customer replaceable units (CRUs) 25 D danger statements 2 dc good LED 168 diagnostic error codes 170 programs, overview 168 - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 228
, 115 intermittent problems 149 J jumpers 13 L LEDs 7 Ethernet activity 8 Ethernet-link status 8 front 5 power-channel error 193 rear view 7 riser-card assembly 16 system board 15 location LED 8 locator LED 6 M memory module branch 89 210 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 229
supply specifications 4 power-control button 6 power-control-button shield 6 power-cord connector 7 power-on LED 8 rear 6 power-on password override switch 14 problem isolation tables 147 problems Ethernet controller 194 hard disk drive 148 intermittent 149 keyboard 150 memory 151 microprocessor - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 230
125 trademarks 202 U undetermined problems 194 Universal Serial Bus (USB) problems 161 updating firmware 17 USB connector 6, 8 using EasyStartup 18 utility program IBM ServeRAID Configuration 21 212 ThinkServer RD120 server Machine Types 6444, 6445, 6446, and 6447: Hardware Maintenance Manual - Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 231
- Lenovo ThinkServer RD120 | Hardware Maintenance Manual for RD120 - Page 232
Part Number: 46U0863 Printed in USA (1P) P/N: 46U0863
ThinkServer RD120 server Machine Types 6444, 6445,
6446, and 6447
Hardware Maintenance Manual