Power-On Self Test (POST), The Data LED turns off.
UPC - 734646183000
View all Lexmark E310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
4044-XXX User Error Message Font Error Resource Save Off Deficient Memory LED Status Data blinking and Error, Press Button on solid Ready blinking and Error, Press Button on solid Action The print command is requesting a font that is not present or installed. The user must select a different font or try turning the Best Fit setting on and retry the print command. The printer lacks sufficient memory to enable Resource Save. It is recommended that the user install additional memory or set each link buffer to the Auto value. Power-On Self Test (POST) When you turn the printer On, it performs a Power-On Self Test. Check for correct POST functioning of the base printer by observing the following: 1. All LEDs turn on solid. 2. All LEDs turn off. 3. The cooling fan and fuser lamp turn on. Note: The fuser lamp turns off once the thermistor reaches operating temperature. As the temperature drops, the lamp turns back on automatically. 4. The LEDs begin to turn on then off sequentially. 5. Once the fuser has reached operating temperature, the main motor turns on and the pick roller shaft assembly rotates to home position. 6. The Ready LED turns on solid while the Data LED blinks. 7. The engine/LVPS board checks the status of the input and exit paper feed sensors. 8. The main motor turns off. 9. The Data LED turns off. Diagnostic Information 2-9