LiftMaster H J- LOGIC 3 Manual

LiftMaster H Manual

LiftMaster H manual content summary:

  • LiftMaster H | J- LOGIC 3 Manual - Page 1
    MANUAL J H HJ INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR This Operator Features the Enhanced INTENAN M A E M E C AL INTENDED FOR PROFESSIONAL INSTALLATION ONLY Visit www.LiftMaster of cycles/months is reached or when the operator requires immediate service. Radio Receiver Built on Board 315MHz NOT
  • LiftMaster H | J- LOGIC 3 Manual - Page 2
    Chart 26 Troubleshooting Guide 27 Troubleshooting Error Codes 28 Troubleshooting Radio Functionality 29 REPAIR PARTS Electrical Box 30-31 Repair Parts Kits - Model J 32-33 Repair Parts Kits - Model H 34-35 Repair Parts Kits - Model HJ 36-37 Operator Notes 38-39 Control Connection Diagram
  • LiftMaster H | J- LOGIC 3 Manual - Page 3
    AND CAUTION LABELS HARDWARE BOX (INCLUDES FASTENERS, DISCONNECT AND CHAIN HOIST WALL BRACKET) 3-BUTTON CONTROL STATION WITH LED HOIST HAND CHAIN (MODELS H AND HJ ONLY) DOOR SPROCKET DOOR/OPERATOR DRIVE CHAIN OPERATOR DIMENSIONS WEIGHTS AND DIMENSIONS HANGING WEIGHT: 80-110 LBS. (36.3-49.9 kg
  • LiftMaster H | J- LOGIC 3 Manual - Page 4
    with open override. See pages 16 and 17 for optional wiring types and operating modes. LIMIT ADJUST Linear driven, fully adjustable screw type cams. MECHANICAL DRIVE REDUCTION Primary: Heavy duty (5L) V-Belt Secondary: #48 chain/sprocket; Output: #50 chain OUTPUT SHAFT SPEED 36 RPM DOOR SPEED
  • LiftMaster H | J- LOGIC 3 Manual - Page 5
    order. The handing is indicated by last letter of the model name (R or L). The hand chain wheel can not be switched on site. If your installation causes the hand chain to hang in the door opening, hook the chain off to the side near the top of the door jamb. Shaft Support Bracket with Bearing (Not
  • LiftMaster H | J- LOGIC 3 Manual - Page 6
    to door shaft and sprockets are aligned. When in position, secure the operator to wall or mounting bracket. 7. Align sprockets and secure (Figure 3). 8. Install Hand Chain (Models H and HJ only) Place hand chain around hand chain wheel. Be sure to pass it through both openings in the chain guide
  • LiftMaster H | J- LOGIC 3 Manual - Page 7
    the door from the door operator and a disconnect chain with manual hoist to electrically disable the operator controls. 1. Refer to Model H instructions for hoist operation. 2. Refer to Model J instructions for manual operation. Electrical Interlock with Hoist for Models H and HJ Keyhole Bracket
  • LiftMaster H | J- LOGIC 3 Manual - Page 8
    door manufacturer, mount the sensing edge on the door according to the instructions provided control station is out of sight of door or ANY other control (automatic or manual) is used. Reversing devices are recommended for ALL installations. WIRING For wiring of your sensing device to the operator
  • LiftMaster H | J- LOGIC 3 Manual - Page 9
    to protect the door and motorized operator. It is NOT door by hand during travel. 4. Reinstall cotterpin. WARNING To prevent possible SERIOUS INJURY or DEATH, install CAUTION reversing sensors when the 3-button control station is out of sight of the door or ANY other control (automatic or manual
  • LiftMaster H | J- LOGIC 3 Manual - Page 10
    that time the unit may be returned to service. • Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with local electrical codes. The operator should be on a separate fused line of adequate capacity. • ALL electrical connections MUST be
  • LiftMaster H | J- LOGIC 3 Manual - Page 11
    On all models a radio terminal bracket marked R1 R2 R3 is located on the outside of the electrical enclosure. In B2 mode the operator will then open a fully closed door, close a fully open door, stop an opening door, and reverse a closing door from the radio remote. In TS control wiring the
  • LiftMaster H | J- LOGIC 3 Manual - Page 12
    DIAGRAMS Radio Control (24V DC only) CPS-L & CPS-LN4 R3 R2 R1 Sensing Edge Timer Defeat Switch Maintenance Alert LED (RD) (WH) Open Close Stop Open/Close Single Button OPEN CLOSE STOP 3-Button Station Remove Jumper To Install External Interlock Single Phase Power Wiring Line Power 115
  • LiftMaster H | J- LOGIC 3 Manual - Page 13
    ) and purple (PU) motor wires are reversed for H and HJ right hand models and all GH and J models. CPS-L & CPS-LN4 Sensing Edge Hoist Interlock When Present TMR DEF SWITCH (YE) (BL) Maintenance Alert LED (RD) (WH) Open Close Stop OPEN CLOSE STOP 3-Button Station Open/Close Single Button
  • LiftMaster H | J- LOGIC 3 Manual - Page 14
    ) and purple (PU) motor wires are reversed for H and HJ right hand models and all GH and J models. Sensing Edge CPS-L & CPS-LN4 Hoist Interlock When Present TMR DEF SWITCH (YE) (BL) Maintenance Alert LED (RD) (WH) Open Close Stop OPEN CLOSE STOP 3-Button Station Open/Close Single Button
  • LiftMaster H | J- LOGIC 3 Manual - Page 15
    D14 P1 D34 MAS 10 EYES 9 EDGE 8 OPEN 7 CLOSE 6 STOP 5 CMN 4 3 2 SBC 1 F1 C54 C71 C78 ® Motor Direction Jumper Single Phase and Three Phase Jumper Maintenance Alert System Button for Programming Open Button Close Button Stop Button Control Wiring Terminal Block Wiring Type Selector Dial Failsafe
  • LiftMaster H | J- LOGIC 3 Manual - Page 16
    PROGRAMMING LOGIC CONTROL PUSHBUTTONS OPEN, CLOSE, STOP Open, Close and Stop buttons are mounted directly on the logic board. Thus, making it easy to program as well as have door control at the electrical box. Either the stop control or a jumper must be wired between terminals 4 and 5 for the on
  • LiftMaster H | J- LOGIC 3 Manual - Page 17
    Compatible with 3-Button Station, 1-Button Station and 1- and 3-Button Remote Controls. (NOTE: Requires Optional self monitoring photo eyes to operate.) FSTS Momentary button contact for open, close and stop programming. Radio controls allowing open, close and stop. User set mid stop. User set
  • LiftMaster H | J- LOGIC 3 Manual - Page 18
    button remote control is not supported with D1 and E2 wiring modes. SINGLE BUTTON REMOTE CONTROL PROGRAMMED AS A SINGLE BUTTON CONTROL (SBC) This function programs a remote control as a wireless single button control. This function will work in the following modes: In B2 mode, operation is OPEN/STOP
  • LiftMaster H | J- LOGIC 3 Manual - Page 19
    Your 315MHz Security✚®or dip switch remote control can be programmed to operate as a 3-button wireless control station: the large button will open the door, the middle button will close the door, and the third button will stop the door's movement. You may set up this feature as follows: 1. To
  • LiftMaster H | J- LOGIC 3 Manual - Page 20
    2 or more flashes in a row followed by a pause, an operator error occurred. Turn to page 28 to diagnose problem. Example: A door is installed with 30,000 cycle springs and has an annual service contract. To set the MAS, turn selector dial to PROGRAM, press MAS button, press the STOP button to clear
  • LiftMaster H | J- LOGIC 3 Manual - Page 21
    , T or FSTS. TO PROGRAM MANUALLY (Method 1): SELECTOR DIAL 1. Close the door. 2. Turn the selector dial to PROGRAM. 3. Press the TIMER button on the logic board. 4. Press the STOP button to clear the timer. 5. Press the OPEN button for every 5 seconds the operator should wait before attempting
  • LiftMaster H | J- LOGIC 3 Manual - Page 22
    close only one time for safety purposes. SELECTOR DIAL Operation will vary depending on wiring type CAR DEALER MODE Feature: The car dealer mode uses the SBC (Single Button Control input) to bring the door from a closed position to the programmed Open Mid-Stop position and keep it at that location
  • LiftMaster H | J- LOGIC 3 Manual - Page 23
    Reversal System not applicable on models GH and GT.) NOTE: This feature is automatically learned and does not require programming. LOSE OPEN RPM Sensor Logic Board MAXIMUM RUN TIMER (MRT) Feature: The operator can learn the time it takes to open or close the door plus an additional 10 seconds
  • LiftMaster H | J- LOGIC 3 Manual - Page 24
    close. Benefit: Advanced warning of the door closing helps prevent traffic collisions with the door. Light Control Module Operation: The green lights on the OPTION BOARD will turn on if the board is seated properly and the power is on. When the door reaches the full open limit or mid stop, the timer
  • LiftMaster H | J- LOGIC 3 Manual - Page 25
    feature can help determine how long the operator has been in service. 1. Start with the door in the closed position. 2. Turn the SELECTOR DIAL to DIAG (diagnostic mode). 3. Press and release the MAS button on the logic board. 4. Press and release the MRT button on the logic board. 5. The open and
  • LiftMaster H | J- LOGIC 3 Manual - Page 26
    LEDs to assist in the installation and troubleshooting of the operator. The following chart should assist in verifying the operator is functioning properly. Turn the selector dial to DIAGNOSTIC to keep the door from moving while troubleshooting. LED Power Stop Open Close Eyes Timer Defeat OLS CLS
  • LiftMaster H | J- LOGIC 3 Manual - Page 27
    TROUBLESHOOTING GUIDE FAULT THE OPERATOR WILL NOT RESPOND TO ANY COMMANDS POSSIBLE CAUSE FIX a) No power supply b) Operator control station is wired wrong c) Interlock switch is activated d) Dial still in programming or diagnostic mode e) Motor is malfunctioning f) Motor thermal overload tripped
  • LiftMaster H | J- LOGIC 3 Manual - Page 28
    troubleshoot some problems with the operator. If the MAS LED is flashing on and off rapidly, the Maintenance Alert System has been triggered and the schedule operator service operation. E2 No RPM input during opening or closing The door or connected. 1. Check AC line for voltage. 2. Check
  • LiftMaster H | J- LOGIC 3 Manual - Page 29
    PROBLEM CORRECTION Quick Flash Unlearned remote control - Try re-learning the A user tries to use a remote remote control (page 18). control, but the RADIO LED only flashes briefly and there is no response from the operator. No LED activity Cannot recognize remote control- Replace battery
  • LiftMaster H | J- LOGIC 3 Manual - Page 30
    7 5 ELECTRICAL BOX 8 1 4 2 11 K2 (K72-12515-1) 3 9 6 10 K1 (K72-14130-1) 30
  • LiftMaster H | J- LOGIC 3 Manual - Page 31
    motor or brake components be sure to match model number of your unit to kit number below to ensure proper voltage requirements. SERVICE KITS ITEM K1 K2 PART the model number of your operator. For example: H5011L3 (Operator) = K-H5011L3 (Electrical box kit) INDIVIDUAL PARTS ITEM PART #
  • LiftMaster H | J- LOGIC 3 Manual - Page 32
    MODEL J 15 16 14 1 3 4 7 2 5 6 2 6 11 13 3 12 8 K1 (K72-19975) 9 K2 (K72-19974) 10 32
  • LiftMaster H | J- LOGIC 3 Manual - Page 33
    Volt models Brake kit - 230-460 Volt models Brake kit - 575 Volt models Complete with: Brake hub kit, brake release lever, brake disk, spring cup, studs, compression springs, brake solenoid, solenoid cover, spacers, mounting plate, pressure plate, feather key, and conduit. INDIVIDUAL PARTS ITEM
  • LiftMaster H | J- LOGIC 3 Manual - Page 34
    MODEL H 34 8 6 5 17 18 19 16 2 4 3 1 2 14 7 7 K1 (K72-19979) 13 15 10 9 11 K2 (K72-19974) 12
  • LiftMaster H | J- LOGIC 3 Manual - Page 35
    REPAIR PARTS KITS - MODEL H SERVICE KITS ITEM PART # DESCRIPTION K1 K72-19979 Clutch shaft kit Complete with: Clutch shaft, keyed flange bearing, dual sprocket 32/14, 14 tooth sprocket, e-ring, compression spring, chain wheel assembly, pulley assembly, chain guide assembly, shim washer,
  • LiftMaster H | J- LOGIC 3 Manual - Page 36
    MODEL HJ 36 19 9 7 5 20 21 18 2 22 2 10 4 6 3 1 16 12 14 8 7 K1 15 (K72-19982) 17 12 11 13 12 K2 (K72-19974)
  • LiftMaster H | J- LOGIC 3 Manual - Page 37
    disk, spring cup, studs, compression springs, brake solenoid, solenoid cover, spacers, mounting plate, pressure plate, feather key, and conduit. K73-HJFRAME-L HJ frame kit, left hand K73-HJFRAME-R HJ frame kit, right hand INDIVIDUAL PARTS ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
  • LiftMaster H | J- LOGIC 3 Manual - Page 38
    OPERATOR NOTES 38
  • LiftMaster H | J- LOGIC 3 Manual - Page 39
    OPERATOR NOTES 39
  • LiftMaster H | J- LOGIC 3 Manual - Page 40
    added to ensure proper installation and operation with the Commercial Door Operator. 3 BUTTON STATION OR 3 POSITION OPEN / CLOSE 14 B2, T, TS & FSTS MODE ONLY See note 2. Open Open Close Close RADIO CONTROLS OPEN / CLOSE R1 R2 R3 D1 & E2 MODE ONLY See note 2. Any Commercial Type LiftMaster
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

J H HJ
INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR
ogic
L
3
NOT FOR RESIDENTIAL USE
A
L
E
R
T
S
Y
S
T
E
M
M
A
I
N
T
E
N
A
N
C
E
PATENT PENDING
The Maintenance Alert Systemâ„¢ allows the
installer to set an internal Maintenance
Cycle Counter. The Logic 3 operator
incorporates a self-diagnostic feature built
into the (MAS) Maintenance Alert System
LED. An LED on the 3-button station will
signal
when
the
set
number
of
cycles/months is reached or when the
operator requires immediate service.
This Operator Features
the Enhanced
Radio Receiver
Built on Board
Serial # Box
Installation Date
2
YEAR
WARRANTY
315MHz
Visit www
.LiftMaster
.com
to locate a professional installing dealer in your area.
INTENDED FOR PROFESSIONAL
INSTALLATION ONLY
A SAFETY DEVICE IS HIGHLY RECOMMENDED
O W N E R ’ S M A N U A L