LiftMaster J J LOGIC VERSION 2-575V Manual

LiftMaster J Manual

LiftMaster J manual content summary:

  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 1
    OWNER'S MANUAL MODELS: J H HJ LOGIC CONTROL (VER. 2.0) INDUSTRIAL DUTY DOOR OPERATOR LOGIC LCONTROL FACTORY SET C2 will signal when the set number of cycles is reached or when the opener requires immediate service. 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 2
    Chain Attachment 4 INSTALLATION INSTRUCTIONS Mounting Header Bracket 5 Mounting Operator 5 Operator Support 6 Straight Arm Attachment 6 ENTRAPMENT PROTECTION ACCESSORIES Sensing Edges & Photo Eyes 7 LIMIT SWITCH ADJUSTMENT Limit Location 7 Adjustment 7 POWER & CONTROL WIRING Safety Warnings
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 3
    .........80-110 LBS. 14.44" 7.27" 7.17" 2.00" 17.63" 14.60" 4.63" MOUNTING DIMENSIONS A - Wall Mounting B - Bracket Mounting (rolling door) 3/8" BOLT 7.56" 4.41" 6.59" A B 5.50" B 1.50" A B 13.75" B 8.83" 7.31" 16.50" 3 Hand Chain Wheel present with Models H and HJ only. A A 4.56"
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 4
    Figure 1. Shaft Support Bracket with Bearing (Not Supplied) Door Sprocket WARNING ALL DOORS INTENDED TO BE MOTOR OPERATED SHOULD BE MANUFACTURED WITH SOLID DOOR SHAFTS. 52-11/2/4" " FIGURE 1 OPERATOR PREPARATION Both J and H series operators have dual output shafts and may be mounted on either
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 5
    9098 Optimum Distance 12 - 15" Optimum Distance 12 - 15" Typical Right Hand Wall Mounted Operator FIGURE 3 IMPORTANT: The shelf or bracket must provide adequate support, prevent play between operator and door shaft, and permit operator to be fastened securely and with the drive shaft parallel to
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 6
    HJ Keyhole Bracket Model HJ This operator includes both a floor level disconnect chain to disconnect the door from the door operator and and a disconnect chain with manual hoist to electrically disable the operator controls. 1. Refer to Model H instructions for hoist operation. 2. Refer to Model
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 7
    LiftMaster Authorized Dealer. If not pre-installed by the door manufacturer, mount the sensing edge on the door according to the instructions the door. COIL CORD: Connect operator end of coil cord to junction box (not supplied) fastened to the wall approximately halfway up the door opening. LIMIT
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 8
    back of this manual. DO NOT INSTALL ANY WIRING OR ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM. IMPORTANT SAFETY NOTES WARNINGWARNING WARNINGWARNING INSTALL THE CONTROL STATION IN LINE OF SIGHT WITH THE DOOR, BUT AWAY FROM THE DOOR AND ITS HARDWARE. IF CONTROL STATION CANNOT
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 9
    SERVICE. RADIO CONTROLS On all models with B2 control wiring, a terminal bracket marked R1 R2 R3 is located on the outside of the electrical enclosure. Any commercial type LiftMaster brand receiver may be mounted to this bracket. The operator will then open a fully closed door, close a fully open
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 10
    System will return the door to the full open position. The Auxiliary Reversal System is designed to protect the door and motorized operator. It is not intended as a replacement for a safety sensing device, nor will it work for sectional doors when a jackshaft operator is used. WARNING CAUTION
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 11
    LOGIC CONTROL (VER. 2.0) 1 PHASE WIRING DIAGRAM 1837-1 230 VOLT MOTOR CONNECTION NOTE: CONTACTOR 1PH / 3PH SHOULD BE IN 1 PH POSITION. 115 VOLT MOTOR CONNECTION Note: 1) See Owner's Manual for Dip Switch Functions and Programming Procedures 2) TO REVERSE MOTOR DIRECTION 115 VOLTS: ALWAYS EXCHANGE
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 12
    See Owner's Manual for Dip Switch Functions and Programming Procedures 2) TO REVERSE MOTOR DIRECTION: INTERCHANGE ANY 2 OF THE 3 POWER WIRES AT L1, L2 & L3, OR EXCHANGE PURPLE & GRAY MOTOR LEADS AT BOARD CONNECTIONS E17 & E6 (3PH UNITS ONLY). **- Transformer Primary Voltage same as Line Voltage. 12
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 13
    STANDARD POWER & CONTROL CONNECTION DIAGRAM Logic Control Board (VER. 2.0) - 115V, 208, 230V, 1Ph 13
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 14
    STANDARD POWER & CONTROL CONNECTION DIAGRAM Logic Control Board (VER. 2.0) - 208, 230V, 380V, 460V, 3Ph 14
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 15
    component locations. Before Programming the logic board, set the operators open and close limits. LEDs instructions. Logic Control Pushbuttons Open, Close, Stop Open, Close and Stop buttons are mounted directly on the Logic Control board. This will provide easy programming ability and door control
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 16
    for open, close and stop. Radio controls allowing open, close and stop. User set midstop. User set Timer To Close. The FSTS single button station opens the door to the full open limit bypassing the mid stop and activates the Timer To Close, putting the operator in TS mode until the door reaches
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 17
    cause of motor failure is eliminated. The auxiliary reversing benefits of the RPM sensor are designed to prevent excessive door and operator damage upon hitting a solid obstruction. LiftMaster recommends the use of safety devices for primary safety protection. To Program: 1. The open and close
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 18
    control station when the preset number of cycles is reached. Setting this feature is optional. By default, this feature will never activate. Open Benefit: The consumer will be aware of when it is time for a scheduled main- tenance on the door or operator. Close To Program: 1. Close the door
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 19
    Program: 1. Close the door. 2. Set dip switches to "Set Timer To Close" 3. Press "close" to zero out the timer. 4. Press "open" for every 5 seconds seconds the operator should wait before attempting to close the door. Example: The door next operation command. Open Close Stop Single Button Control
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 20
    LOGIC 2.0 PCB BOARD ILLUSTRATION RPM LEARN BUTTON (SEE PAGE 17) POWER WIRING TERMINAL BLOCK (SEE PAGES 8-9) DIP SWITCH (SEE PAGES 8-9) CONTROL WIRING TERMINAL BLOCK (SEE PAGES 8-9) OPEN, CLOSE, STOP BUTTONS 20
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 21
    a) Operator control station is wired wrong b) Motor is malfunctioning RESOLUTION Reset the RPM sensor. Also verify that the software is version 260 or better. Order replacement chips from Parts and Service. Reset the Maximum Run Timer Reset the mid-stop by programming it to be at the open limit
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 22
    not lit call for more assistance. 2. Check your control station: A. Place the operator into diagnostic mode (all DIP switches ON) B. Watch the LEDs as each control button is pressed. The LEDs should light with each Open, Close, and Single Button Control command. The Stop should turn off the LED
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 23
    . n Do not lubricate motor. Motor bearings are rated for continuous operation. n Do not lubricate clutch or V-belt. n Inspect and service whenever a malfunction is observed or suspected. n CAUTION: BEFORE SERVICING, ALWAYS DISCONNECT OPERATOR FROM POWER SUPPLY. HOW TO ORDER REPAIR PARTS OUR LARGE
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 24
    ILLUSTRATED PARTS - ELECTRICAL BOX S2 S1 S6 S5 S3 S7 S8 S4 S9 11 L3 6 7 8 L5 2 L8 L6 5 L2 1 3 L1 L7 L3 L8 L9 4 5 L2 L6 L4 9 10 24
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 25
    REPAIR PARTS KITS - ELECTRICAL BOX LOGIC CONTROL (VER. 2.0) Below are replacement kits available for your operator. For replacement of electrical box, motor or brake components be sure to match model number of your unit to kit number below to ensure proper voltage requirements. Optional
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 26
    ILLUSTRATED PARTS - Model J 5 6 7 1 8 9 C8 C20 C10 C9 D1 D7 D4 D8 D11 D3 D10 D9 D2 D5 D6 C4 C21 C6 C16 C24 C7 C17 C14 C18 C3
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 27
    REPLACEMENT PARTS KITS - MODEL J LOGIC CONTROL (VER. 2.0) Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or remove from these lists. Individual components
  • LiftMaster J | J LOGIC VERSION 2-575V Manual - Page 28
    ILLUSTRATED PARTS - Model H 5 6 D1 D7 D4 D8 D11 D3 C12 1 D10 D9 D2 D5 D6 C15 C6 C2 C17 C5 C7 C19 C16 C18 C4 C25 C18 C19
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

OWNER'S MANUAL
MODELS:
J
H HJ
LOGIC CONTROL (VER. 2.0)
INDUSTRIAL DUTY DOOR OPERATOR
Serial #
(located on electrical box cover)
Installation Date
Wiring Type
2 YEAR WARRANTY
LOGIC CONTROL
L
C2 Wiring
FACTORY SET
See pages 15 and 16
for other wiring
configurations
The Maintenance Alert System
allows the installer to set an internal
Maintenance Cycle Counter. An LED
on the 3-button station will signal when
the set number of cycles is reached or
when the opener requires immediate
service.
TM
PATENT PENDING
NOT FOR RESIDENTIAL USE
LISTED
DOOR
OPERATOR
41B6