LiftMaster SL3000501U SL3000501U Installation Manual

LiftMaster SL3000501U Manual

LiftMaster SL3000501U manual content summary:

  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 1
    Model SL3000 ELITE SERIES COMMERCIAL HIGH-TRAFFIC AC SLIDE GATE OPERATOR INSTALLATION MANUAL SL3000101U 1 HP Single Phase SL3000501U 1/2 HP Single Phase • THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. • This model is for use on vehicular passage gates ONLY
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 2
    DEVICES 33 SETTINGS 34 GATE OPERATOR SETUP EXAMPLES 34 DUAL GATE SETTINGS 35 MAINTENANCE 36 IMPORTANT SAFETY INFORMATION 36 MAINTENANCE 36 TROUBLESHOOTING 37 DIAGNOSTIC CODES 37 OPERATOR ALARM 40 TROUBLESHOOTING CHART 41 ACCESSORIES 43 REPAIR PARTS 44 WARRANTY 45
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 3
    that accompany it. Read them carefully. IMPORTANT NOTE: • BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. • DO NOT attempt repair or service of your gate operator unless you are an Authorized
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 4
    reduce the risk of INJURY or DEATH: • READ AND FOLLOW ALL INSTRUCTIONS. • NEVER let children operate or play with gate controls. Keep is not moving. • KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate hardware. • The entrance is for vehicles
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 5
    • Photoelectric Sensors • Screen Mesh • Vertical Posts • Instructional and Precautionary Signage 4. Install the gate operator only when: For a gate operator utilizing a non-contact sensor: a. Reference owner's manual regarding placement of non-contact sensor for each type of application. See
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 6
    An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator. stationary object nearest the roadway, (such as a gate support post) and the gate frame when the gate is in that the gate will enter a receiver guide, refer to ASTM F2200 for panel
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 7
    INTRODUCTION CARTON INVENTORY NOT SHOWN: Documentation Packet, Chain #41 - 30 feet, Eye Bolt Kit Operator Cover Warning Signs (2) and Warranty Card Key (2) LiftMaster Monitored Retro-Reflective Photoelectric Sensor TOOLS NEEDED • 1/2" wrench for cover screw 5/16" • 3/4" wrench for 1/2"
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 8
    INTRODUCTION OPERATOR SPECIFICATIONS This model is intended for use in vehicular slide gate applications: Usage Classification Main AC Supply Accessory Power Maximum Gate Weight Minimum Gate Travel Distance Maximum Gate Travel Distance Maximum Gate Travel Speed Maximum Daily Cycle Rate Maximum
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 9
    INTRODUCTION SITE PREPARATION Check the national and local building codes BEFORE installation. CONDUIT & CONCRETE PAD Conduit must be UL approved for low and high voltage. Consider the operator placement BEFORE installing the pad or post. SAFETY Entrapment protection devices are required to
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 10
    INTRODUCTION OVERVIEW OF TYPICAL INSTALLATION IMPORTANT SAFETY INFORMATION: One or more external monitored entrapment protection sensors shall be located where the risk of entrapment or obstruction exists at either the opening or closing direction. Any gap larger than 2-1/4 inches between the gate
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 11
    INSTALLATION • To AVOID damaging gas, power or other underground utility lines, contact underground utility locating companies BEFORE digging more than 18 inches (46 cm) deep. • DO NOT touch the heater when switch is on, heater may be hot. TYPES OF INSTALLATIONS STANDARD INSTALLATION Operator
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 12
    INSTALLATION STEP 1 DETERMINE LOCATION FOR CONCRETE PAD AND OPERATOR Check the national and local building codes before installation. STANDARD INSTALLATION 1. The gate operator should be installed near the front roller of the gate. Lay out the concrete pad. 2. Install the electrical conduit. 3. Pour
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 13
    INSTALLATION STEP 2 INSTALL THE OPERATOR Attach the operator to the concrete pad with appropriate fasteners. The gate operator should be installed near the front roller of the gate or near the back of the gate (in the OPEN position). The space between the gate and the output sprocket must be a
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 14
    3 ATTACH THE CHAIN DO NOT run the operator until instructed. 1. Manually open the gate and line up the front bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the front bracket in this position. 2. Manually close the gate and line up the rear bracket so
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 15
    INSTALLATION To prevent SERIOUS INJURY or DEATH from a moving gate: • ALL gate operator systems REQUIRE two independent entrapment protection systems for each entrapment zone. • Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. • Locate entrapment
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 16
    protection devices depending on the specific device and how the device will function. Refer to the specific entrapment protection device manual for more information. These entrapment protection device inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 17
    operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. • Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 18
    INSTALLATION STEP 6 continued... POWER WIRING 1. Make sure the AC power switch on the operator is OFF (the AC power switch will turn the incoming 120/240 Vac power ON or OFF). 2. Turn off the AC power from the main power source circuit breaker. 3. Run the AC power wires to the junction box on the
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 19
    INSTALLATION STEP 7 DUAL GATES ONLY There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. WIRELESS DUAL GATES TO ACTIVATE THE WIRELESS FEATURE: 1. Choose an operator to be
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 20
    INSTALLATION STEP 7 continued... DUAL GATES ONLY DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE) 22AWG up to 200 feet (61 m) 18AWG - 200-1000 feet (61-305 m) Wire must be rated at 30 Volt minimum WIRED DUAL GATES Before digging, contact local underground utility locating companies. Use PVC
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 21
    will be set during this cycle. READJUST THE LIMITS To readjust the limits, follow the "Set the Limits" and "Set the Force and Run Distance" instructions above. It is important that the force and run distance are set after every limit readjustment. Limit Nuts Limit Switches 19
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 22
    INSTALLATION STEP 9 (continued) ADJUST THE HANDING AND LIMITS ERASE THE HANDING 1. To erase the handing, press and hold the OPEN LEFT and OPEN RIGHT buttons simultaneously (5 seconds) until both the OPEN LEFT and OPEN RIGHT LEDs blink rapidly and the operator beeps. 2. Release the buttons and the
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 23
    switch on the operator will turn the incoming 120 Vac power ON or OFF. JUNCTION BOX Page 31 1 HP OPERATOR COVER MANUAL RELEASE HANDLE Pull the manual release handle to manually open and close the gate. RESET BUTTON • Press the reset button to stop a moving gate during a normal open/close cycle
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 24
    CONTROL BOARD OVERVIEW CONTROL BOARD REFERENCE BIPART DELAY Page 23 LEARN BUTTON Pages 23, 32-33 DIAGNOSTIC DISPLAY Pages 23, 37-39 TIMER-TO-CLOSE Page 23 FORCE DIAL Page 24 TEST BUTTONS Pages 24, 37 HANDING BUTTONS Pages 19, 23 BIPART DELAY 4 2 6 OPEN LEFT OPEN 8 RIGHT HANDING
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 25
    operator type as SL3000U. The firmware version will show after the operator type, example "1.2". For more information about the codes refer to the Troubleshooting section. HANDING BUTTONS The handing buttons are used to determine which direction the gate will open and they are also used to set the
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 26
    open direction. 5 4 3 2 1 6 7 8 9 10 TEST BUTTONS Used to operate the gate (OPEN, STOP and CLOSE). Also used to view the code history (refer to the Troubleshooting section). LED INPUT POWER TIMER GATE MOVING ACC PWR OVLD STATE OFF ON OFF ON 1 blink/second 2 blinks/second 8 blinks/second OFF ON
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 27
    WIRE ACCESSORIES TO CONTROL BOARD TERMINALS OPEN and COMM CLOSE and COMM STOP and COMM THREE BUTTON CONTROL STATION FUNCTION WIRING EXAMPLE Opens a closed gate. Hard open (maintained switch overrides external safeties and resets alarm condition). If maintained, pauses Timer-to-Close at OPEN
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 28
    WIRE ACCESSORIES TO CONTROL BOARD PHOTOELECTRIC SENSORS AND EDGE SENSORS The EYES/EDGE terminals are used for connecting entrapment protection devices. At least one external monitored entrapment protection device is required prior to gate movement. Monitored entrapment protection devices should
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 29
    EXPANSION BOARD OVERVIEW To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks. PLUG-IN LOOP DETECTOR INPUTS For Plug-In Loop Detectors (Model LOOPDETLM) SHADOW INTERUPT EXIT OPEN CLOSE POWER 1 EYE ONLY 2
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 30
    ON ON OFF Not used. ON OFF ON Energizes if gate is manually tampered with by being pushed off of close limit. For an additional ,000.). Cycle count displayed is between 1,000 and 9,999,000 cycles. After servicing, set Aux Relay switches back to their appropriate positions. Cycle count cannot be
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 31
    WIRE ACCESSORIES TO EXPANSION BOARD PHOTOELECTRIC SENSORS AND EDGE SENSORS The EYES/EDGE terminals are used for connecting entrapment protection devices. At least one external monitored entrapment protection device is required prior to gate movement. Monitored entrapment protection devices should
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 32
    WIRE ACCESSORIES TO EXPANSION BOARD INPUTS EXIT SHADOW INTERRUPT LOOPS FUNCTIONALITY WIRING EXAMPLE Loop wire connection for plug-in loop detector when loop is inside secured area near gate. • Open command - opens a closed gate • Soft open (maintained switch does not override external safeties
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 33
    ADDITIONAL WIRING To protect against fire and electrocution: • DISCONNECT power BEFORE installing or servicing operator. For continued protection against fire: • Replace ONLY with fuse of same type and rating. FIELD WIRING BIPART DELAY 4 2 6 OPEN LEFT OPEN 8 RIGHT HANDING CONTROL
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 34
    installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 35
    PROGRAMMING LIFTMASTER INTERNET GATEWAY (NOT PROVIDED) To program the operator to the LiftMaster Internet Gateway: Program using the learn button on the operator's control board: 1. Connect the ethernet cable to the LiftMaster Internet Gateway and the router. 2. Connect power to the LiftMaster
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 36
    or visual alert system). Attach alert signal (audible or visual alert system) to indicate if gate is manually tampered with by being pushed off of close limit. Use during servicing only to determine operator cycles. Typically not required. The heater keeps the gearbox and batteries at a suitable
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 37
    SETTINGS DUAL GATE SETTINGS NOTE: We recommend that all accessories and board configurations are set on the primary operator. MAIN CONTROL BOARD FEATURE PRIMARY OPERATOR Timer-to-Close Set the TTC dial to desired setting OFF SECONDARY OPERATOR Bi-Part Delay Switch Bi-Part Delay: ON (will
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 38
    • SAVE THESE INSTRUCTIONS. To protect against fire and electrocution: • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. For to the operator before servicing. DESCRIPTION TASK Entrapment Protection Devices Warning Signs Manual Disconnect Drive Chain and
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 39
    TROUBLESHOOTING To protect against fire and electrocution: • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. For continued protection against fire: • Replace ONLY with fuse of same type and rating. DIAGNOSTIC CODES TO VIEW THE CODES The codes will show
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 40
    TROUBLESHOOTING DIAGNOSTIC CODES continued... Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 41
    TROUBLESHOOTING DIAGNOSTIC CODES continued... Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 42
    TROUBLESHOOTING OPERATOR ALARM If a contact sensor detects an obstruction twice consecutively the alarm will sound (up to 5 minutes) and the operator will need to be reset.
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 43
    TROUBLESHOOTING TROUBLESHOOTING CHART SYMPTOM Operator does not run and diagnostics display not the gate moves at least four feet between the OPEN limit and the CLOSE limit. a) Use manual disconnect, manually move gate, and ensure gate moves easily limit to limit. Repair gate as needed. b) Gate
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 44
    TROUBLESHOOTING TROUBLESHOOTING CHART continued... SYMPTOM POSSIBLE CAUSES Shadow loop does not keep gate at open limit. a) Vehicle detector setup incorrectly b) Defective vehicle loop detector Obstruction in a) Force
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 45
    ACCESSORIES UNIVERSAL REMOTE CONTROLS 813LM 811LM SECURITY+ 2.0TM LEARNING REMOTE CONTROLS 894LT 892LT LIFTMASTER INTERNET GATEWAY 828LM INTERNET PROTOCOL ACCESS CONTROL IPAC PLUG IN LOOP DETECTOR LOOPDETLM 3 BUTTON CONTROL STATION 02-103 STOP BUTTON AEXITP LIFTMASTER DOOR AND GATE MONITOR
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 46
    REPAIR PARTS NOT SHOWN #41 Chain (10 feet) #40 Chain (10 feet) #41 Chain (Nickel Plated) #41 Master Link #40 Master Link Plastic Standoffs for main control board (10 per bag) Wire Harnesses (main board to power board, main board to ground, main board to transformer, and power board to transformer)
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 47
    this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product returned for warranty repair
  • LiftMaster SL3000501U | SL3000501U Installation Manual - Page 48
    01-37920 845 Larch Avenue Elmhurst, Illinois 60126-1196 LiftMaster.com © 2015, LiftMaster - All Rights Reserved
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

ELITE SERIES COMMERCIAL HIGH-TRAFFIC
AC SLIDE GATE OPERATOR
Model
SL3000
INSTALLATION MANUAL
LiftMaster
845 Larch Avenue
Elmhurst, IL 60126-1196
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE
SYSTEMS TECHNICIAN ONLY.
This model is for use on vehicular passage gates ONLY and not intended for use
on pedestrian passage gates.
This model is intended for use in Class I, II, III and IV vehicular slide gate
applications.
Visit LiftMaster.com to locate a professional installing dealer in your area.
This gate operator is compatible with MyQ
®
and Security+ 2.0
TM
accessories.
SL3000101U
1 HP Single Phase
SL3000501U