LiftMaster SL585105U SL585151U Installation Manual

LiftMaster SL585105U Manual

LiftMaster SL585105U manual content summary:

  • LiftMaster SL585105U | SL585151U Installation Manual - Page 1
    SL585 ELITE SERIES INDUSTRIAL AC SLIDE GATE OPERATOR INSTALLATION MANUAL SL585101U 1 HP, 120/208-240 Vac Single Phase Phase SL585505U 1/2 HP, 575 Vac Three Phase • THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. • This model is for use on vehicular passage
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 2
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 3
    DEVICES 37 SETTINGS 38 GATE OPERATOR SETUP EXAMPLES 38 DUAL GATE SETTINGS 39 MAINTENANCE 40 IMPORTANT SAFETY INFORMATION 40 MAINTENANCE 40 TROUBLESHOOTING 41 DIAGNOSTIC CODES 41 OPERATOR ALARM 44 TROUBLESHOOTING CHART 45 ACCESSORIES 47 REPAIR PARTS 48 WARRANTY 49 1
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 4
    that accompany it. Read them carefully. IMPORTANT NOTE: • BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. • DO NOT attempt repair or service of your gate operator unless you are an Authorized
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 5
    reduce the risk of INJURY or DEATH: • READ AND FOLLOW ALL INSTRUCTIONS. • NEVER let children operate or play with gate controls. Keep is not moving. • KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate hardware. • The entrance is for vehicles
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 6
    • Photoelectric Sensors • Screen Mesh • Vertical Posts • Instructional and Precautionary Signage 4. Install the gate operator only when: For a gate operator utilizing a non-contact sensor: a. Reference owner's manual regarding placement of non-contact sensor for each type of application. See
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 7
    An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator. stationary object nearest the roadway, (such as a gate support post) and the gate frame when the gate is in that the gate will enter a receiver guide, refer to ASTM F2200 for panel
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 8
    INTRODUCTION CARTON INVENTORY NOT SHOWN: Documentation Packet, Chain #50 - 24 feet, Eye Bolt Kit Gate Brackets Warning Signs (2) and Warranty Card Operator Hardware LiftMaster Monitored Retro-Reflective Photoelectric Sensor TOOLS NEEDED • 3/4" wrench for 1/2" concrete anchors • Screwdrivers (
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 9
    INTRODUCTION OPERATOR SPECIFICATIONS This model is intended for use in vehicular slide gate applications: Usage Classification Accessory Power Maximum Gate Weight Minimum Gate Travel Distance Maximum Gate Travel Distance Maximum Gate Travel Speed Maximum Daily Cycle Rate Maximum Duty Cycle
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 10
    INTRODUCTION OPERATOR SPECIFICATIONS HP 1/2 1 1-1/2 Phase Single Three Single Three Single Vac 120 Vac 208-240 Vac 208-240 Vac 480 Vac 575 Vac 120 Vac 208-240 Vac 208-240 Vac 480 Vac 575 Vac 120 Vac 208-240 Vac Main AC Supply Full Load Amps 11.2 Amps (17.2 Amps including Accessory Outlets) 5.6
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 11
    INTRODUCTION SITE PREPARATION Check the national and local building codes BEFORE installation. CONDUIT & CONCRETE PAD Conduit must be UL approved for low and high voltage. Consider the operator placement BEFORE installing the pad or post. SAFETY Entrapment protection devices are required to
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 12
    INTRODUCTION OVERVIEW OF TYPICAL INSTALLATION IMPORTANT SAFETY INFORMATION: One or more external monitored entrapment protection sensors shall be located where the risk of entrapment or obstruction exists at either the opening or closing direction. Any gap larger than 2-1/4 inches between the gate
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 13
    INSTALLATION • To AVOID damaging gas, power or other underground utility lines, contact underground utility locating companies BEFORE digging more than 18 inches (46 cm) deep. • DO NOT touch the heater when switch is on, heater may be hot. • To prevent damage to the operator or gate, DO NOT drive
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 14
    INSTALLATION STEP 1 INSTALL THE OPERATOR Check the national and local building codes before installation. PAD MOUNT INSTALLATION RETRO-FIT INSTALLATION The operator is shipped from the factory with the lower mounting angles configured out (Figure 1). If you have pad constrictions, either angle can
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 15
    INSTALLATION STEP 1 (continued) INSTALL THE OPERATOR Check the national and local building codes before installation. POST MOUNT INSTALLATION RETRO-FIT INSTALLATION The operators come from the factory configured to mount to an inside the frame post mount dimension of 26" (66 cm) (outside to
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 16
    instructed. 1. Mount gate brackets to the vertical front and rear posts of the gate. 2. Remove the operator cover. 3. Locate and engage the manual chain guide, around drive and idler sprockets, and then through the second plastic chain guide chain support. Vent Plug Pin Gate brackets must be level
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 17
    the maximum separation distance of the photoelectric sensors, then edge sensors MUST BE USED. Refer to the photoelectric sensor instructions for maximum separation distance. ProIpnesridtye PrOopuetsrtiyde Sensors for Close Cycle CONTACT SENSORS (EDGE SENSORS) If the electrically activated edge
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 18
    protection devices depending on the specific device and how the device will function. Refer to the specific entrapment protection device manual for more information. These entrapment protection device inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 19
    operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. • Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with national and local electrical codes
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 20
    INSTALLATION STEP 5 (continued) POWER WIRING SINGLE PHASE The operator is field configurable for usage at 120, 208, and 240 Vac. Factory default is 120 Vac. For 208 Vac Operation Unplug the motor harness from the "120V" receptacle on the power board and plug the harness in to the "208V / 240V"
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 21
    INSTALLATION STEP 5 (continued) POWER WIRING THREE PHASE The operator is field configurable for usage at 208, 240, and 480 Vac. Factory default is 240 Vac. For three phase 575V operators, the operator is configured at the factory for 575V ONLY. For 208 Vac Operation Ensure the motor harness is
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 22
    INSTALLATION STEP 6 DUAL GATES ONLY There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. WIRELESS DUAL GATES TO ACTIVATE THE WIRELESS FEATURE: 1. Choose an operator to be
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 23
    INSTALLATION STEP 6 continued... DUAL GATES ONLY DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE) 22AWG up to 200 feet (61 m) 18AWG - 200-1000 feet (61-305 m) Wire must be rated at 30 Volt minimum WIRED DUAL GATES Before digging, contact local underground utility locating companies. Use PVC
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 24
    this cycle. Limit Switches Limit Nuts READJUST THE LIMITS To readjust the limits, follow the "Set the Limits" and "Set the Force and Run Distance" instructions above. It is important that the force and run distance are set after every limit readjustment. 22
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 25
    INSTALLATION STEP 7 (continued) ADJUST THE HANDING AND LIMITS ERASE THE HANDING 1. To erase the handing, press and hold the OPEN LEFT and OPEN RIGHT buttons simultaneously (5 seconds) until both the OPEN LEFT and OPEN RIGHT LEDs blink rapidly and the operator beeps. 2. Release the buttons and the
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 26
    INSTALLATION STEP 9 OBSTRUCTION TEST The operator is equipped with an automatic obstruction sensing feature. If the gate encounters an obstruction during motion, the operator will automatically reverse direction of the gate for a short time and then stop the gate. After any adjustments are made,
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 27
    Page 22 EXPANSION BOARD Pages 31-34 TERMINAL BLOCK For additional accessory wiring. Page 35 OPERATOR ALARM Page 44 MANUAL RELEASE HANDLE Pull the manual release handle to manually open and close the gate. CONTROL BOARD Pages 26-30 POWER BOARD COVER OPTIONAL LOCKS Location for additional locks
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 28
    CONTROL BOARD OVERVIEW CONTROL BOARD REFERENCE BIPART DELAY Page 27 LEARN BUTTON Pages 27, 36-37 DIAGNOSTIC DISPLAY Pages 27, 41-43 TIMER-TO-CLOSE Page 27 FORCE DIAL Page 28 TEST BUTTONS Pages 28, 41 HANDING BUTTONS Pages 22, 27 BIPART DELAY 4 2 6 OPEN LEFT OPEN 8 RIGHT HANDING
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 29
    operator type as SL585. The firmware version will show after the operator type, example "1.2". For more information about the codes refer to the Troubleshooting section. HANDING BUTTONS The handing buttons are used to determine which direction the gate will open and they are also used to set the
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 30
    adjustment. 5 4 3 2 1 6 7 8 9 10 TEST BUTTONS Used to operate the gate (OPEN, STOP and CLOSE). Also used to view the code history (refer to the Troubleshooting section). LED INPUT POWER TIMER GATE MOVING ACC PWR OVLD STATE OFF ON OFF ON 1 blink/second 2 blinks/second 8 blinks/second OFF ON
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 31
    WIRE ACCESSORIES TO CONTROL BOARD TERMINALS OPEN and COMM CLOSE and COMM STOP and COMM THREE BUTTON CONTROL STATION FUNCTION WIRING EXAMPLE Opens a closed gate. Hard open (maintained switch overrides external safeties and resets alarm condition). If maintained, pauses Timer-to-Close at OPEN
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 32
    WIRE ACCESSORIES TO CONTROL BOARD PHOTOELECTRIC SENSORS AND EDGE SENSORS The EYES/EDGE terminals are used for connecting entrapment protection devices. At least one external monitored entrapment protection device is required prior to gate movement. Monitored entrapment protection devices should
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 33
    EXPANSION BOARD OVERVIEW To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks. PLUG-IN LOOP DETECTOR INPUTS For Plug-In Loop Detectors (Model LOOPDETLM) SHADOW INTERUPT EXIT OPEN CLOSE POWER 1 EYE ONLY 2
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 34
    ON ON OFF Not used. ON OFF ON Energizes if gate is manually tampered with by being pushed off of close limit. For an additional ,000.). Cycle count displayed is between 1,000 and 9,999,000 cycles. After servicing, set Aux Relay switches back to their appropriate positions. Cycle count cannot be
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 35
    WIRE ACCESSORIES TO EXPANSION BOARD PHOTOELECTRIC SENSORS AND EDGE SENSORS The EYES/EDGE terminals are used for connecting entrapment protection devices. At least one external monitored entrapment protection device is required prior to gate movement. Monitored entrapment protection devices should
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 36
    WIRE ACCESSORIES TO EXPANSION BOARD INPUTS EXIT SHADOW INTERRUPT LOOPS FUNCTIONALITY WIRING EXAMPLE Loop wire connection for plug-in loop detector when loop is inside secured area near gate. • Open command - opens a closed gate • Soft open (maintained switch does not override external safeties
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 37
    ADDITIONAL WIRING To protect against fire and electrocution: • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. For continued protection against fire: • Replace ONLY with fuse of same type and rating. FIELD WIRING BIPART DELAY 4 2 6 OPEN LEFT OPEN 8 RIGHT
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 38
    installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 39
    PROGRAMMING LIFTMASTER INTERNET GATEWAY (NOT PROVIDED) To program the operator to the LiftMaster Internet Gateway: Program using the learn button on the operator's control board: 1. Connect the ethernet cable to the LiftMaster Internet Gateway and the router. 2. Connect power to the LiftMaster
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 40
    system) to indicate if gate is manually tampered with by being pushed off of close limit. Use during servicing only to Use during servicing only to determine operator cycles. determine operator cycles. Use during servicing only to Use during servicing only to determine operator cycles. determine
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 41
    SETTINGS DUAL GATE SETTINGS NOTE: We recommend that all accessories and board configurations are set on the primary operator. MAIN CONTROL BOARD FEATURE PRIMARY OPERATOR Timer-to-Close Set the TTC dial to desired setting OFF SECONDARY OPERATOR Bi-Part Delay Switch Bi-Part Delay: ON (will
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 42
    • SAVE THESE INSTRUCTIONS. To protect against fire and electrocution: • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. For to the operator before servicing. DESCRIPTION TASK Entrapment Protection Devices Warning Signs Manual Disconnect Drive Chain and
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 43
    TROUBLESHOOTING To protect against fire and electrocution: • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. For continued protection against fire: • Replace ONLY with fuse of same type and rating. DIAGNOSTIC CODES TO VIEW THE CODES The codes will show
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 44
    TROUBLESHOOTING DIAGNOSTIC CODES continued... Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 45
    TROUBLESHOOTING DIAGNOSTIC CODES continued... Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 46
    TROUBLESHOOTING OPERATOR ALARM If a contact sensor detects an obstruction twice consecutively the alarm will sound (up to 5 minutes) and the operator will need to be reset.
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 47
    TROUBLESHOOTING TROUBLESHOOTING CHART SYMPTOM POSSIBLE CAUSES Operator does not a) No power to the gate moves at least four feet between the OPEN limit and the CLOSE limit. a) Use manual disconnect, manually move gate, and ensure gate moves easily limit to limit. Repair gate as needed. b) Gate
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 48
    TROUBLESHOOTING TROUBLESHOOTING CHART continued... SYMPTOM POSSIBLE CAUSES Shadow loop does not keep gate at open limit. a) Vehicle detector setup incorrectly b) Defective vehicle loop detector Obstruction in a) Force
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 49
    maximum separation distance of the photoelectric sensors, then edge sensors MUST BE USED. Refer to the photoelectric sensor instructions for maximum separation distance. LiftMaster Monitored Through Beam Photoelectric Sensor (LMTBU) LiftMaster Monitored Retro Reflective Photoelectric Sensor (LMRRU
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 50
    K32-34792 Sprocket, 50B12 X 1" K15-50B12LGH Bearing Kit K12-4164 Idler Shaft Kit Complete with: Bearings, sprocket 50B12x1" and idler shaft K75-34828 Chain Guide K75-18493 Brake Solenoid 115V K22-120 575V K22-575-1 3 phase K22-36900 Limit Chain K19-48069-NP Brake Hub Kit Complete with: Brake hub
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 51
    this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product returned for warranty repair
  • LiftMaster SL585105U | SL585151U Installation Manual - Page 52
    01-37914B 845 Larch Avenue Elmhurst, Illinois 60126-1196 LiftMaster.com © 2015, LiftMaster - All Rights Reserved
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

ELITE SERIES INDUSTRIAL
AC SLIDE GATE OPERATOR
Model
SL585
INSTALLATION MANUAL
LiftMaster
845 Larch Avenue
Elmhurst, IL 60126-1196
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE
SYSTEMS TECHNICIAN ONLY.
This model is for use on vehicular passage gates ONLY and not intended for use on
pedestrian passage gates.
This model is intended for use in Class I, II, III and IV vehicular slide gate
applications.
Visit LiftMaster.com to locate a professional installing dealer in your area.
This gate operator is compatible with MyQ
®
and Security+ 2.0
accessories.
SL585101U
1 HP, 120/208-240 Vac Single Phase
SL585103U
1 HP, 208-240/480 Vac Three Phase
SL585105U
1 HP, 575 Vac Three Phase
SL585151U
1-1/2 HP, 120/208-240 Vac Single Phase
SL585501U
1/2 HP, 120/208-240 Vac Single Phase
SL585503U
1/2 HP, 208-240/480 Vac Three Phase
SL585505U
1/2 HP, 575 Vac Three Phase