LiftMaster SL595UL UPDATED Gate Safety Checklist
LiftMaster SL595UL Manual
View all LiftMaster SL595UL manuals
Add to My Manuals
Save this manual to your list of manuals |
LiftMaster SL595UL manual content summary:
- LiftMaster SL595UL | UPDATED Gate Safety Checklist - Page 1
Gates prevented from falling over if disconnected from supporting hardware Pass / Fail SWING Distance from pivot fully closed positions Pass / Fail Receiver guides recessed behind receiver post for receiver guides less than 8 ft. Pass / 2018 LiftMaster All Rights Reserved 300 Windsor Drive, - LiftMaster SL595UL | UPDATED Gate Safety Checklist - Page 2
) Interior posts, Non-pinch rollers (2x) Guide posts Edge sensor on Trailing Edge of gate xed stationary object nearest the roadway (such as a gate support post) and the gate frame when the gate is in either See device and operator manuals for complete instruction. Visit DAMSA.com for
Swing and Slide Gate Operator UL 325 and
ASTM F2200 Site Planning Safety Checklist
Name:
Address:
City/State/ZIP:
Phone:
Email:
Please Print
ASTM F2200 Standards
Gate Construction Evaluation:
Gate Constructed with Safety in mind. ASTM F2200 Standards are followed
Component:
Result
(Circle)
Comments:
Figures (On Back)
All Gates
Gates have smooth bottom edges, no protrusions exceed 1/2” beyond base of gate
Pass
/
Fail
5
All access controls at least 6 ft. from gate
Pass
/
Fail
1,4
Barbed tape (razor wire) at least 8 ft. above grade
Pass
/
Fail
Barbed wire at least 6 ft. above grade
Pass
/
Fail
Separate pedestrian gate – out of reach of a moving gate – vehicular gate is
for automotive traffic only
Pass
/
Fail
1,4
Gate does not move on its own if disconnected from operator
Pass
/
Fail
Gates prevented from falling over if disconnected from supporting hardware
Pass
/
Fail
SWING
Distance from pivot point to column edge is less than 4 in.
Pass
/
Fail
4
Distance from open gate to wall or column greater than 16 in. or external
entrapment protection is provided
Pass
/
Fail
4
SLIDE
Roller covers on wheels
Pass
/
Fail
1
Meshing installed up to 6 ft. above grade if pickets spaced equal to or
greater than 2 1/4 in. apart
Pass
/
Fail
3
Gap between gate and fence post less than 2 1/4 in. & gap protected with safety device
Pass
/
Fail
2
Positive stops at both fully open and fully closed positions
Pass
/
Fail
1
Receiver guides recessed behind receiver post for receiver guides less than 8 ft.
Pass
/
Fail
Other:
Pass
/
Fail
© 2018 LiftMaster All Rights Reserved
300 Windsor Drive, Oak Brook, IL 60523
LMSPCLSWSL 4/18
Please Print
First & Last Name of Dealer:
Name of Dealership:
Dealership Address
(Street Address/City/State/Zip)
:
Dealer Signature:
Customer Signature:
First & Last Name of Installer:
Phone:
Installer Signature:
Satisfactory
Needs Repair/Replacement
Gate Safety Check
—
Simple steps to quickly determine if an End User’s gate operator is safe.
UL 325 Standard
Component:
Result
(Circle)
Comments:
Figures (On Back)
1. Gate Operator is approved to current UL 325 standards
(check operator label)
Pass
/
Fail
2. Proper gate warning signs attached to both sides of gate area
Pass
/
Fail
1,4
3. All entrapment zones protected by 2 safety devices/obstruction tested
1,4
Close Side
(circle two)
Photo Eye
Reversing Edge
Inherent Reverse
Pass
/
Fail
Open Side
(circle two)
Photo Eye
Reversing Edge
Inherent Reverse
Pass
/
Fail
Other Entrapment Areas
Pass
/
Fail
*Entrapment Zone: The location where an object can be caught or held in a position that increases the risk of injury