LiftMaster SL595UL Installation Manual

LiftMaster SL595UL Manual

LiftMaster SL595UL manual content summary:

  • LiftMaster SL595UL | Installation Manual - Page 1
    This model is intended for use in Class I, II, III and IV vehicular slide gate applications. • Visit LiftMaster.com to locate a professional installing dealer in your area. • This gate operator is compatible with MyQ® and Security+ 2.0® accessories. Access installation and technical support guides
  • LiftMaster SL595UL | Installation Manual - Page 2
    LiftMaster Instructions 38 Maintenance Chart 38 TROUBLESHOOTING 39 Diagnostic Codes 39 Diagnostic Codes Table 40 Operator Alarm 42 Troubleshooting manual and follow all safety instructions. • DO NOT attempt repair or service of your gate operator unless you are an Authorized Service
  • LiftMaster SL595UL | Installation Manual - Page 3
    devices. IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of INJURY or DEATH: l READ AND FOLLOW ALL INSTRUCTIONS. l NEVER let children not moving. l KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate hardware. l The entrance is for
  • LiftMaster SL595UL | Installation Manual - Page 4
    a gate operator utilizing a non-contact sensor: a. Reference owner's manual regarding placement of non-contact sensor for each type of application. See Screen Mesh by a moving gate or barrier. l Vertical Posts l Instructional and Precautionary Signage 4. Install the gate operator only when: a. The
  • LiftMaster SL595UL | Installation Manual - Page 5
    . An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator. fixed stationary object nearest the roadway, (such as a gate support post) and the gate frame when the gate is in the gate will enter a receiver guide, refer to ASTM F2200 for panel
  • LiftMaster SL595UL | Installation Manual - Page 6
    INTRODUCTION Carton Inventory NOT SHOWN: Documentation Packet, Chain #50 - 25 feet, Eye Bolt Kit Tools Needed 3/4" wrench for 1/2" concrete anchors, Screwdrivers (phillips head and flat head), Cable cutters and strippers 6
  • LiftMaster SL595UL | Installation Manual - Page 7
    Rate Continuous Maximum Duty Cycle Continuous Operating Temperature Without Heater: -20°C to 60°C (-4°F to 140°F) With optional heater model HTRNB or model HTR460 (460V installations only): -40°C to 60°C (-40°F to 140°F) Expansion Board Provided External Entrapment Protection Device Inputs
  • LiftMaster SL595UL | Installation Manual - Page 8
    20 Amps (26 Amps including Accessory Outlets) 10 Amps Accessory Outlets are rated for 120 Vac, 6 Amps maximum. NOTE: The outlet is only available on models with 120 Vac input. The 120 Vac outlet is automatically disabled when the operator is configured for any voltage other then 120 Vac. For 240
  • LiftMaster SL595UL | Installation Manual - Page 9
    INTRODUCTION Site Preparation Check the national and local building codes BEFORE installation. Conduit and Concrete Pad Trench and install conduit. Before trenching, contact underground utility locating companies. Conduit must be UL approved for low and high voltage. Consider the operator
  • LiftMaster SL595UL | Installation Manual - Page 10
    INSTALLATION l To AVOID damaging gas, power or other underground utility lines, l To prevent damage to the operator or gate, DO NOT drive the limit contact underground utility locating companies BEFORE digging more (nuts) actuators on the shaft past their normal positions. than 18 inches (46 cm)
  • LiftMaster SL595UL | Installation Manual - Page 11
    INSTALLATION Install Without Adjustable Rails Check the national and local building codes before installation. NOTE: The rails will have to be removed for retro-fit installations. 1. Locate and anchor two posts made of 3" (7.6 cm) outer diameter heavy walled pipe. Posts should be parallel and square
  • LiftMaster SL595UL | Installation Manual - Page 12
    instructed. 1. Mount gate brackets to the vertical front and rear posts of the gate. 2. Remove the operator cover. 3. Locate and engage the manual chain through the plastic chain guide, around drive and idler sprockets, and then through the second plastic chain guide toward front gate bracket.
  • LiftMaster SL595UL | Installation Manual - Page 13
    Safety Guide l LiftMaster monitored external entrapment protection devices MUST be used with LiftMaster operators to meet UL325 requirements, see Accessories. l Test ALL entrapment protection devices after completing installation of the operator. For testing instructions, refer to the manual
  • LiftMaster SL595UL | Installation Manual - Page 14
    protection devices depending on the specific device and how the device will function. Refer to the specific entrapment protection device manual for more information. These entrapment protection device inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge
  • LiftMaster SL595UL | Installation Manual - Page 15
    wiring diagram. switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. l ALL power wiring should be on a dedicated circuit and well protected. The location of the power disconnect should be visible and clearly l Disconnect
  • LiftMaster SL595UL | Installation Manual - Page 16
    INSTALLATION Single Phase The operator is field configurable for usage at 120, 208, and 240 Vac. Factory default is 120 Vac. For 208 Vac Operation For 480 Vac Operation Unplug the motor harness from the "120V" receptacle on the power board and plug the harness in to the "208V / 240V" receptacle.
  • LiftMaster SL595UL | Installation Manual - Page 17
    208, 240, and 480 Vac. Factory default is 240 Vac. For three phase 575V operators, the operator is configured at the factory for 575V ONLY (Models SL595105UL and SL595205UL). For 208 Vac Operation For 480 Vac Operation Ensure the motor harness is plugged in to the "208V / 240V" receptacle on the
  • LiftMaster SL595UL | Installation Manual - Page 18
    INSTALLATION Step 6 Dual Gate Setup There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. Wireless setup To activate the wireless feature: 1. Choose an operator to be the
  • LiftMaster SL595UL | Installation Manual - Page 19
    INSTALLATION Wired setup Before digging, contact local underground utility locating companies. Use PVC conduit to prevent damage to cables. DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE) 22AWG up to 200 feet (61 m) 18AWG - 200-1000 feet (61-305 m) Wire must be rated at 30 Volt minimum 1.
  • LiftMaster SL595UL | Installation Manual - Page 20
    ADJUSTMENT Adjust the Handing and Limits To reduce the risk of SEVERE INJURY or DEATH: l Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a moving gate. l Too much force on gate will interfere with proper operation of
  • LiftMaster SL595UL | Installation Manual - Page 21
    ADJUSTMENT Readjust the Limits To readjust the limits, follow the "Set the Limits" and "Set the Force and Run Distance" instructions above. It is important that the force and run distance are set after every limit readjustment. Adjust the Clutch The friction clutch system is not
  • LiftMaster SL595UL | Installation Manual - Page 22
    ADJUSTMENT Fine Tune the Force Once the initial limits have been set, the REVERSAL FORCE DIAL on the control board is used for fine tuning the force where wind or environmental changes may affect the gate travel. The REVERSAL FORCE DIAL is set to minimum at the factory. Based on the length and
  • LiftMaster SL595UL | Installation Manual - Page 23
    OPERATOR OVERVIEW 23
  • LiftMaster SL595UL | Installation Manual - Page 24
    CONTROL BOARD OVERVIEW 24
  • LiftMaster SL595UL | Installation Manual - Page 25
    the operator type as SL595. The firmware version will show after the operator type, example "1.2". For more information about the codes refer to the Troubleshooting section. Handing Buttons The handing buttons are used to determine which direction the gate will open and they are also used to set the
  • LiftMaster SL595UL | Installation Manual - Page 26
    wear or temperature changes Test Buttons Used to operate the gate (OPEN, STOP and CLOSE). Also used to view the code history (refer to the Troubleshooting section). Status LEDs LED INPUT POWER TIMER GATE MOVING ACC PWR OVLD STATE OFF ON OFF ON 1 blink/second 2 blinks/second 8 blinks/second OFF ON
  • LiftMaster SL595UL | Installation Manual - Page 27
    WIRE ACCESSORIES TO CONTROL BOARD All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings. Three
  • LiftMaster SL595UL | Installation Manual - Page 28
    WIRE ACCESSORIES TO CONTROL BOARD Photoelectric Sensors and Edge Sensors The EYES/EDGE terminals are used for connecting entrapment protection devices. At least two external monitored entrapment protection devices are required prior to gate movement; one in the open and one in the closed direction
  • LiftMaster SL595UL | Installation Manual - Page 29
    LOOPDETLM) detects a fault, then the gate will open and remain open until fault is cleared. CLOSE: If the EXIT plug-in loop detector (model LOOPDETLM) detects a fault, faults are ignored (EXIT loop is faulted and inoperative). AC FAIL Switch NOT USED ANTI TAIL Switch OFF: When CLOSE EYES/Interrupt
  • LiftMaster SL595UL | Installation Manual - Page 30
    or light (low voltage). Not used. Energizes if gate is manually tampered with by being pushed off of close limit. For an 163,000.). Cycle count displayed is between 1,000 and 9,999,000 cycles. After servicing, set Aux Relay switches back to their appropriate positions. Cycle count cannot be reset
  • LiftMaster SL595UL | Installation Manual - Page 31
    WIRE ACCESSORIES TO EXPANSION BOARD Photoelectric Sensors and Edge Sensors The EYES/EDGE terminals are used for connecting entrapment protection devices. At least two external monitored entrapment protection devices are required prior to gate movement; one in the open and one in the closed
  • LiftMaster SL595UL | Installation Manual - Page 32
    WIRE ACCESSORIES TO EXPANSION BOARD Loops TERMINALS EXIT SHADOW INTERRUPT FUNCTION Loop wire connection for plug-in loop detector when loop is inside secured area near gate. l Open command - opens a closed gate l Soft open (maintained switch does not override external safeties and does not reset
  • LiftMaster SL595UL | Installation Manual - Page 33
    ADDITIONAL WIRING To protect against fire and electrocution: l DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. For continued protection against fire: l Replace ONLY with fuse of same type and rating. Field Wiring 33
  • LiftMaster SL595UL | Installation Manual - Page 34
    installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation
  • LiftMaster SL595UL | Installation Manual - Page 35
    the primary operator (the operator will beep as it enters learn mode). The LiftMaster Internet Gateway will pair to the operator if it is within range and the ONE gate operator (see the KPW5/KPW250 manual for complete programming instructions). The Constant Pressure Override feature is intended to
  • LiftMaster SL595UL | Installation Manual - Page 36
    alert system) to indicate if gate is manually tampered with by being pushed off of close limit. Cycle Quantity Feedback Use during servicing only to determine operator cycles. Use during servicing only to determine operator cycles. Use during servicing only to determine operator cycles. Use
  • LiftMaster SL595UL | Installation Manual - Page 37
    Tandem Mode: OFF SECONDARY OPERATOR OFF Bi-Part Delay: OFF (will open first and close last) Tandem Mode: OFF ACCESSORY Remote Controls LiftMaster Internet Gateway Garage and Gate Monitor PRIMARY OPERATOR Program remote controls 1 to 50 to the primary operator. Program to primary operator. Program
  • LiftMaster SL595UL | Installation Manual - Page 38
    manual. national and local electrical codes. NOTE: The operator should be on Have a qualified service person make repairs to gate hardware. a separate fused line of adequate capacity. l ALL maintenance MUST be performed by a LiftMaster GATE. l SAVE THESE INSTRUCTIONS. l The entrance is for
  • LiftMaster SL595UL | Installation Manual - Page 39
    TROUBLESHOOTING To protect against fire and electrocution: l DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. For continued protection against fire: l Replace ONLY with fuse of same type and rating. Diagnostic Codes To View the Codes The codes will show
  • LiftMaster SL595UL | Installation Manual - Page 40
    TROUBLESHOOTING Diagnostic Codes Table Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear. LiftMaster System Installed System Informational External Entrapment Protection Inherent Entrapment
  • LiftMaster SL595UL | Installation Manual - Page 41
    TROUBLESHOOTING Code 70 71 72 73 74 75 80 81 82 83 84 91 93 95 the connections between the main board and the expansion board. Non-monitored contact closure devices are not supported. Make sure connected devices are monitored. Check edges for proper orientation and resistive end cap connection.
  • LiftMaster SL595UL | Installation Manual - Page 42
    TROUBLESHOOTING Operator Alarm If a contact sensor detects an obstruction twice consecutively the alarm will sound (up to 5 minutes) and the operator will need to be reset.
  • LiftMaster SL595UL | Installation Manual - Page 43
    TROUBLESHOOTING Troubleshooting Chart SYMPTOM Operator does not run and diagnostic display not on the gate moves at least four feet between the OPEN limit and the CLOSE limit. a. Use manual disconnect, manually move gate, and ensure gate moves easily limit to limit. Repair gate as needed. b. Gate
  • LiftMaster SL595UL | Installation Manual - Page 44
    TROUBLESHOOTING SYMPTOM Shadow loop does not keep gate at open limit. Obstruction in gate's path does not cause gate to stop and reverse. Photoelectric sensor does
  • LiftMaster SL595UL | Installation Manual - Page 45
    MUST BE USED. Refer to the photoelectric sensor instructions for maximum separation distance. LiftMaster monitored through beam photoelectric sensor Model LMTBUL LiftMaster monitored retro-reflective photoelectric sensor Model LMRRUL LiftMaster monitored wireless edge kit (transmitter and receiver
  • LiftMaster SL595UL | Installation Manual - Page 46
    Horse Power ID, 575V 2 HP K94-38062-6 Wire Harness K77-38121 Alarm Kit K94-37884 Plastic Standoffs for main control board (10) K77-37683 C Clamp, SL595UL (2) K77-38105 46
  • LiftMaster SL595UL | Installation Manual - Page 47
    Two Year Limited Warranty LiftMaster warrants to the first purchaser of this product, for the pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of purchase
  • LiftMaster SL595UL | Installation Manual - Page 48
    300 Windsor Drive Oak Brook, IL 60523 LiftMaster.com © 2018, The Chamberlain Group, Inc. - All Rights Reserved 01-39376B
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

ELITE SERIES HEAVY DUTY INDUSTRIAL
AC SLIDE GATE OPERATOR
Model
SL595UL
INSTALLATION MANUAL
LiftMaster
300 Windsor Drive
Oak Brook, IL 60523
THIS PRODUCT IS TO BE INSTALLED AND
SERVICED BY A TRAINED GATE SYSTEMS
TECHNICIAN ONLY.
This model is for use on vehicular passage
gates ONLY and not intended for use on
pedestrian passage gates.
This model is intended for use in Class I, II, III
and IV vehicular slide gate applications.
Visit LiftMaster.com to locate a professional
installing dealer in your area.
This gate operator is compatible with MyQ
®
and Security+ 2.0
®
accessories.
SL595101UL
1 HP, 120/208-240 Vac Single Phase
SL595103UL
1 HP, 208-240/480 Vac Three Phase
SL595105UL
1 HP, 575 Vac Three Phase
SL595151UL
1-1/2 HP, 120/208-240 Vac Single Phase
SL595203UL
2 HP, 208-240/480 Vac Three Phase
SL595205UL
2 HP, 575 Vac Three Phase
Access installation and technical support guides or
register this product
Send it in
by texting the
photo to 71403.
Take a photo
of the
camera icon including
the points (
).
1.
2.
SL595ULTECH