  • Maytag MER5605WB | Installation Instructions - Page 1
    INSTALLATION INSTRUCTIONS 30" (76 CM) FREESTANDING ELECTRIC RANGES Table of Contents RANGE SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements - U.S.A. Only 4 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti-Tip Bracket 6 Electrical
  • Maytag MER5605WB | Installation Instructions - Page 2
    RANGE SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions
  • Maytag MER5605WB | Installation Instructions - Page 3
    home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above. ■ Four-wire power supply cord or cable must be used in a mobile home installation. The appliance wiring will need to be revised. See "Electrical
  • Maytag MER5605WB | Installation Instructions - Page 4
    steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet. Electrical Requirements - U.S.A. Only If codes permit and a separate ground wire
  • Maytag MER5605WB | Installation Instructions - Page 5
    install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. ■ Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating
  • Maytag MER5605WB | Installation Instructions - Page 6
    INSTALLATION INSTRUCTIONS Unpack Range WARNING Excessive Weight Hazard Use two or more people to move and install range. Failure to do so can result in back or other injury. 1. Remove shipping materials, tape and film from range. 2. Remove oven racks and parts package from inside oven. 3. Do not
  • Maytag MER5605WB | Installation Instructions - Page 7
    grounded outlet. Failure to follow these instructions can result in death, fire, or electrical shock. Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire. Electrically ground range. Failure to follow these instructions can result in death, fire, or
  • Maytag MER5605WB | Installation Instructions - Page 8
    Mobile homes ■ Recreational vehicles ■ In an area where local codes prohibit grounding through the neutral 1. Part of metal ground strap must be cut out and removed. A B C 5. Complete installation following instructions for your type of electrical connection: 4-wire (recommended) 3-wire (if 4-wire
  • Maytag MER5605WB | Installation Instructions - Page 9
    on bottom of range. Allow enough slack to easily attach the wiring to the terminal block. A B 3-wire connection: Power Supply black) wires to the outer terminal block posts with 10-32 hex nuts. 7. Securely tighten hex nuts. NOTE: For power supply cord replacement, use only a power cord rated at 250
  • Maytag MER5605WB | Installation Instructions - Page 10
    to your type of electrical supply (4-wire or 3-wire connection). 4-wire Connection: Direct Wire Use this method for: ■ New branch-circuit installations (1996 NEC) ■ Mobile homes ■ Recreational vehicles ■ In an area where local codes prohibit grounding through the neutral 1. Part of metal ground
  • Maytag MER5605WB | Installation Instructions - Page 11
    tighten setscrew to torque as shown in the following Bare Wire Torque Specifications chart. A B C D E A. Terminal lug B. Setscrew C. Line 2 (red) wire D. Bare (green) ground wire E. Line 1 (black) wire Bare Wire Torque Specifications Attaching terminal lugs to the terminal block - 20 lbs-in
  • Maytag MER5605WB | Installation Instructions - Page 12
    To check that the anti-tip bracket is installed, use a flashlight and look underneath the bottom of the range. ■ Look for the anti-tip bracket securely attached to floor. ■ Slide range back so rear range foot is under anti-tip bracket. A Level Range 1. Place rack in oven. 2. Place level on rack
  • Maytag MER5605WB | Installation Instructions - Page 13
    the Use and Care Guide for specific instruction on range operation. If range does not operate, check the following: ■ Household fuse is intact and tight; or circuit breaker has not tripped. ■ Range is plugged into an outlet. ■ Electrical supply is connected. ■ See "Troubleshooting" in the Use and
  • Maytag MER5605WB | Installation Instructions - Page 14
    cord. 5. Check that anti-tip bracket is installed: ■ Look for the anti-tip bracket securely attached to floor. ■ Slide range back so rear range foot is under anti-tip bracket. Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so
  • Maytag MER5605WB | Installation Instructions - Page 15
    Left edge ANTI-TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall. Top edge 15
  • Maytag MER5605WB | Installation Instructions - Page 16
    W10252706B © 2009. All rights reserved. 9/09 Printed in U.S.A.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

INSTALLATION INSTRUCTIONS
30" (76 CM) FREESTANDING ELECTRIC RANGES
Table of Contents
RANGE SAFETY
...................................................................................
2
INSTALLATION REQUIREMENTS
......................................................
3
Tools and Parts
..................................................................................
3
Location Requirements
......................................................................
3
Electrical Requirements - U.S.A. Only
...............................................
4
INSTALLATION INSTRUCTIONS
........................................................
6
Unpack Range
....................................................................................
6
Install Anti-Tip Bracket
.......................................................................
6
Electrical Connection - U.S.A. Only
...................................................
7
Verify Anti-Tip Bracket Location
......................................................
12
Level Range
......................................................................................
12
Storage Drawer
................................................................................
12
Complete Installation
.......................................................................
13
Moving the Range
............................................................................
14
ANTI-TIP BRACKET TEMPLATE
.....................................................
15
IMPORTANT:
Save for local electrical inspector's use.
W10252706B